Loading...
HomeMy WebLinkAbout013-92 (revised) Signal Station - Back Creek District - Backfile01. ,k STAFF SITE PLAN CHECKLIST * This application is not complete if the following are not included: One set of comment sheets from the following agencies along with any marked copies of the plan; �✓VDOT City of Winchester Sanitation Authority L� Inspections Dept. '✓Fire Marshal County Engineer Airport Authority ✓ 2. One copy of the Site Plan application. 3. Five copies of the Site Plan. Town of Stephens City Town of Middletown ✓Health Dept. Parks & Recreation 4. One reproducible copy of the Site Plan (if required). 5. One 35mm. slide of the Site Plan (if required). TRACKING Date �5 Application received. All necessary agency comments received. Fee Paid (amount $ -3CO, 0 ). Soil & Water Conservation Dist. Site Plan to Planning Commission via bi-monthly. Site Plan heard by Planning Commission (if required). Revisions received (if required). Date of approval. Info added to annual report diskette. t I September 21, 1992 Mr. Forrest Brown HC 34 Box 5719 Winchester, Va 22601 Re: Approval of Site Plan #013-92 Dear Forrest: COUNTY of FREDERICK Department of Planning and Development 703 / 665-5651 Fax 703 / 678-0682 The Frederick County Department of Planning administratively approved Site Plan #013-92 for (revised) Signal Station Associates. This site plan calls for the construction of a three bay car wash with an equipment room, two vacuum islands to accommodate three vehicles, perimeter landscaping of the paved parking lot with one silver maple per forty feet for a total of 17 and shrubs placed along the northern border of Route 50, a buffer consisting of existing vegetation and twenty-seven white pines along the southern border of the property as approved on the original site plan, a restriping of the existing handicap parking space in order to meet ADA guidelines per our agreement, rolled asphalt curbing around the site, and an erosion and sediment control, complete with runoff calculations. Please call me regarding any questions. Sincerely, Lanny C. Bise, II Planner I LCB/dc cc: Allan Ebert, Surveyor Mr. James Longerbeam, Supervisor, Back Creek District 9 North Loudoun Street P.O. Box 601 Winchcster, VA 22601 Winchcstcr, VA 22604 0 COUNTY of FREDERICK Department of Planning and Development 703 / 665-5651 Fax 703 / 678-0682 July 14, 1992 Mr. Forrest Brown HC-34, Box 5719 Winchester, Va 22601 Dear Forrest: This letter is in reference to my review of site plan #013-92 for (revised) Signal Station Associates. The overall concept of this plan is fine; however, based on our discussion of July 13th, there are some minor revisions we agreed need to be made before final site plan approval can be given. Here is a list of the revisions: 1) Acreage and zoning of all lots should be shown (lot 2 is missing). 2) Width of the sewage easement should be shown. 3) The dimensions of the required fire lane should be shown. 4) Per our conversation regarding the new restaurant use that was approved on your original site plan as existing office use, instead of increasing the parking as required by the zoning ordinance, you have agreed to make your required handicap space comply with the new American Disabilities Act requirement for a van accessible space of 16 feet by 20 feet. 5) Consideration will be given to the existing design of the vacuum area. As we discussed, the current design could result in problems with traffic flow along the eastern boundary of the site if a car was to pull along side the easternmost vacuum island. I would suggest either moving the curbing ten feet or relocating that entire area. Please contact me regarding any further questions or if clarification is needed. Sincerely, -9-� -:"- ns— Lanny Bise, II Planner I LCB/slk cc: L. Allen Ebert 9 North Loudoun Strcct P.O. Box 601 Winchester, VA 22601 Winchester, VA 22604 APPLICANT'S CHECKLIST Your site,, plan should include the following: Administrative Information Y N 1. Name of proposed development. 2. Name and address of owner. 3. Name and address of developer. 4. Name, address and phone number of designer. 5. Certificate of surveyor, engineer or architect. 6. Date plan prepared and date of revisions. 7. A listing of all conditions placed on the site as a result of a conditional use permit or conditional zoning approval. 8. A space labeled "approved by the Zoning Administrator" for the approval signature and date of approval. General Site Information Y N .,� 9. Location map (scale 1:2000) 10. Magisterial District of site 11. Scale of site plan (not to exceed 1:50) 12. North Arrow 13. Zoning of site 14. Use and zoning of adjoining properties Lots/Uses/Buildings and Structures Y / N V 15. Surveyed boundaries for all lots and parcels 16. Acreage of all lots included in the plan 17. The location and dimensions of all required / setbacks and yard areas V 18. Location of all buildings, structures and uses V 19. The proposed use of each building, structure and area 20. The location and type of all dwelling units 21. Ground floor area and total floor area of all buildings with FAR calculations for commercial and industrial zoning district 22. The height of all buildings and structures 23. The location and dimensions of all signs -7- • 0 Lots/Uses/Buildings and Structures (con't) Y N W� A � II Roads Y N Utilities Y N Parking Y N 24. Location of outdoor lighting fixtures 25. Location and nature of outdoor storage areas 26. Location and area of common open space 27. Location and description of all recreation facilities 28. Location of sidewalks and pedestrian ways 29. Location of outdoor trash receptacles 30. Name and number of existing and planned streets on and adjoining the site 31. Location of existing and planned streets on and adjoining the site 32. Dimensions, boundaries, width, pavement and construction of planned roads 33. Location and dimensions of all proposed entrances from public right-of-ways 34. Location of all utilities, including sewer and water lines with the size of lines, mains and laterals 35. Location and width of all easements, including access, utility and drainage easements �° s 1a�c9 36. Location and nature of fire lanes, fire hydrants and all other facilities necessary to meet the Fire Code requirements 37. Calculations describing the required number of parking and loading spaces 38. Location and dimensions of all parking and loading spaces, driveways, parking aisles, curbing and other features to be used 39. Location and dimension of all handicapped spaces • LI Natural Features Y N 40. Existing and finished contour lines lY#�� 41. Location of steep slopes, woodlands, floodplains wetland, sinkholes and other environmental features 42. Location of streams and drainage ways Landscapingq Y/ N r' 43. Landscaping plan describing location and types of plants to be used 44. Location of required buffers and screening with cross sections or profiles. Erosion and Sediment Control Y N .� 45. A stormwater management plan with run off calculations and location and description of facilities to be used 46. Soil erosion and sedimentation control plan with location, types and examples of provisions to be used • 0 SITE PLAN APPLICATION Complete the following application: DATE �5��✓9Z®'� APPLICATION 1. Development S%� `yam S'�J�✓ 2. Location of Property: R7—S-D &J 7::� (by street name) zD>C-/ 3. Property Owner: Address: 3 S/ �� Telephone: 4. Applicant/Agent: Address: Telephone: 5. Designer: / Address: �J�n/�✓ n , t.� C) I Telephone: 33 Contact: 6. Is this an original or revised Site Plan? Original Revised -5- 7. Total area of parcel to be developed: , 8. Property Information: a) Property ID «1 b) Current Zoning: S-2 c) Present Use: d) Proposed Use: e) Adjoining Property Zoning: f) Adjoining Property Use: g) Magisterial District:tY�� I have read the material included in this package and understand what is required by the Frederick County Planning Department. I also understand that all required material will be complete prior to the submission of my site plan. signature:-�—pro✓ Date: w _ RECEIVED *IV 2 ? 1991 Frederick County Engineering Depart Attn: Director of Engineering P.O. Box 601 Winchester, Virginia 22601 (703) 665-5643 The Frederick County Engineering Department is located at 9 North Loudoun St., 2nd Floor of the Hammon Building in Winchester, if you prefer to hand deliver this review. Applicant's name, address and phone number: Name of development and/or description of the request: Location: Engineers Comments: Engineers Signature & Date'lCIU2', t , --7A �ApsylAdul- 1211(��f (NOTICE TO ENGINEERING DEPT. LEA RETURN THIS IFORM TO A PrICANT. NOTICE TO APPLICANT It is your responsibility to complete this form as accurately as possible in order to assist the agency with their review. Also, please attach two copies of your plans and/or application form. -13- STORMWATER DETENTION DESIGN S16-1JIfZ- 'Si� %n l PHASE II U.S. ROUTE 50 WEST BACK CREEK DISTRICT FREDERICK COUNTY VIRGINIA ZONED B-2 L. ALLEN EBERT PROFESSIONAL LAND SURVEYOR 35 W. BOSCAWEN STREET WINCHESTER, VIRGINIA (703) 667 3233 i� • I/ PROJECT: 5 l6-AJ i4L. 0 i /4 T/d ni PHASE II L I A :FER I I IAdf' P 1fll1Rf"'Y'1+Y U.S. ROUTE 50 WEST BACK CREEK DISTRICT FREDERICK COUNTY VIRGINIA 5/6,1JAL 5 i 4W/0N Phase II of the For -eat 411a Development increases the impervious area to 0.723 acres from 0.717 acres in Phase I. Based on the new figure for the impervious area, the attached spreadsheet was calculated. The maximum water surface elevation reached was 2.2 feet for a 100-year storm. The maximum outflow rate was 1.69 cfs, which meets the requirements of being less than the 10-year storm pre - development flow rate of 2.1 cfs. Therefore, the existing stormwater detention pond is adequate to handle the development of Phase II. 0 0 100 YEAR STORM ROUTING - FREDERICK COUNTY CULVERT SIZE: 8 INCHES PROJECT: L. STi¢! 6AI LOCATION: US ROUTE 50 WEST, WINCHESTER, VA POND AREA = 3000 SQ FT BOTTOM POST DEVELOPMENT IMPERVIOUS AREA: 0.723 ACRES WITH 1:1 SLOPE TIME INFLOW AVERAG VOLUME STORAGE TOTAL TRIAL OUTFLW AVE VOLUME BALANCE CORRESP CHK MIN RATE INFLOW CF CARYOVR CF WS ELV RATE OUTFLW OUT IN STOR WS ELEV (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) 0 0 0 0 3.36 0.23 5 6.72 1009 0 1009 0.4 0.46 69 940,/ 0.3 OK 6.10 0.68 10 5.64 1854 940 2794 0.8 0.90 204 2590 0.8 OK 5.21 1.04 15 4.77 1562 2590 4152 1.2 1.18 312 3840 1.2 OK 4.37 1.26 20 3.98 1312 3840 5152 1.4 1.33 377 4776 1.4 OK 3.76 1.38 25 3.54 1128 4776 5903 1.6 1.42 413 5491 1.6 OK 3.36 1.46 30 3.18 1009 5491 6499 1.8 1.50 438 6061 1.8 OK 3.04 1.53 35 2.89 911 6061 6972 1.9 1.55 458 6515 1.9 OK 2.75 1.58 40 2.60 824 6515 7339 2.0 1.61 474 6965 2.0 OK 2.53 1.63 45 2.46 759 6865 7624 2.1 1.65 489 7135 2.0 OK 2.35 1.65 50 2.24 705 7135 7840 2.1 1.65 495 7345 2.1 OK 2.17 1.67 55 2.10 651 7345 7996 2.2 1.69 501 7495 2.1 OK 2.06 1.69 60 2.02 618 7495 8113 2.2 1.69 507 7606 2.2 OK 1.96 1.69 65 1.90 589 760E 8195 2.2 1.69 507 7688 2.2 OK 1.85 1.69 70 1.81 556 76M 8244 2.2 1.69 507 7737 2.2 OK 1.77 1.69 75 1.74 531 7737 8269 2.2 1.69 507 7762 2.2 OK 1.70 1.69 80 1.66 510 7762 8271 2.2 1.69 507 7764 22 OK 1.64 1.69 85 1.63 493 7764 8258 2.2 1.69 507 7751 2.2 OK 1.61 1.69 90 1.58 482 7751 8232 2.2 1.69 507 7725 2.2 OK �� C Y OF FREDERICK, VIRGINIA��� FIRE MARSHAL'S OFFICE LAND DEVELOPMENT COMMENTS Control No. 0105920013 Date Received 112591 Date Reviewed 010592 _____ ____ Applicant Name Forrest L. Brown ___............... __........................ __ Address HE 34, Box 5719 .................... ... .............. _.................. ........ _ Winchester, VA 22601 ��������........... ......... �������������`�������``���...`��.... Project Name Signal Station _____ _ _________________ Type of Application Site Plan Current Zoning B-2 ___ 1st Due Fire Co. 15 1st Due Rescue Co. 15 Election District Back Creek RECOMMENDATIONS Automatic Sprinkler System X Residential Sprinkler System ___ Automatic Fire Alarm System X Other Emergency Vehicle Access; Adequate X Inadequate Not Identified Fire Lanes Required; Yes X No _______ Comments: In accordance with Frederick County Chapter 10 and 8.O.C.A. Building Code. Roadway/Aisleway Widths; Adequate X Inadequate Special Hazards Noted; Yes _ Comments: Not Identified No X Hydrant Locations; Adequate Inadequate Siamese Connection Location; Approved Not Approved Not Identified X Not Identified X Additional Comments: 1) Burning of construction debris is not permitted. 2) Access for emergency vehicles must be maintained at all times during construction. 3) Please post temporary street address signs when construction begins, Review Time .5 hr. Douglas A. Kiracofe » Fire Marshal • • REQUEST FOR SITE PLAN COMMENTS Frederick -Winchester Health Department Attn: Sanitation Engineer P.O. Box 2056 Winchester, Virginia 22601 (703) 722-3480 The Frederick -Winchester Health Department is located at the intersection of Smithfield Avenue and Brick Kiln Road, if you prefer to hand deliver this review form Applicant's name, address /and phone number: IYe- Name of development and/or description of the request: 5;/&._ //4�_ ,S A111? 0A/ Location: Health Department Comments: 0 PoSj P CML- ­24,2f 0 t 1-L P) E To }u,t f uc Fo /'�Z2h- Fv('-i_ Df S O s/rL , 04ST-F_ Flu", ` CAYL WA-s t� 'o bu- %`%D 0t3_C_L-M2G_lz tyF (,0111ISj E WA_)� u mac,, c-, ( iCafUuc ( F of S i (/).4�-M(L LT. JUL Health Signature and Date: %I �� 11 -25 = ' �" S (NOTICE TO HEALTH DEPT. - VLEASRETURNTHI FORM TO APPLICANT.) NOTICE TO APPLICANT It is your responsibility to complete this form as accurately as possible in order to assist the agency with their review. Also, please attach a copy of your plans and/or application form. _10 -12- 0 • REQUEST FOR SITE PLAN COMMENTS Virginia Department of Transportation Attn: Resident Engineer P.O. Box 278 Edinburg, Virginia 22824-0278 (703) 984-4133 The local office of the Transportation Department is located at 1550 Commerce St. in Winchester if you prefer to hand deliver this form. Applicant's name, address and phone number: /71-- -7/ Name of development and/or description of the request: Location: Va. Dept. of Transportation Comments: No objection to site plan. Present entrance is adequate for proposed improvements. Should business ever expand in the future, entrance may need to be upgraded. VDOT Signature and Date: • tdt--S-��e� S Z9 L (NOTICE TO RESIDENT ENGINEER*PLEASE RETURN THIS FORM TO APPL CANT.) NOTICE TO APPLICANT It is your responsibility to complete this form as accurately as possible in order to assist the agency with their review. Also, please attach three copies of your plans and/or application form. RESIDENCY _lo_ ! DEC s 1991 'niNg '�EL 01tr1W • 0 REQUEST FOR SITE PLAN COMMENTS Frederick County Inspections Depa3 Attn: Building Official P.O. Box 601 Winchester, Virginia 22601 (703) 665-5650 RECEIVED 1991 FREDERICK CO. MWERING & 1NSPECTin The Frederick County Inspections Department is located at 9 North Loudoun St., 2nd Floor of the Hammon Building in Winchester, if you prefer to hand deliver this review. Applicant's name, address )and phone number: Y22 l-I� �Y .�`ur S719 L.tdiv�s72✓K G�� ��-�. a I Name of development and/or description of the request: S/ffirir?L S 7�9TJt�•✓ Location: i— a ��iLC Cz cs f rft��5f Inspection Department Comments: Building shall comply with the Virginia Uniform Statewide Building Code and Section 303, Use Group B (Business) of the BOCA National Building Code/1990. Other code that applies is ANSI A117.1-1986 for Physically Handicapped People. , T/Code Administrator Signature & Date: (NOTICE TO INSPECTIONS DEPT.*PLEASE YfttJWR THIS FORM TO PPLICANT.) NOTICE TO APPLICANT It is your responsibility to complete this form as accurately as possible in order to assist the agency with their review. Also, please attach a copy of your plans and/or application form. -14- 0 a SITE PLAN CHECKLIST The site plan application is not complete if the required information is not submitted. All required information must be obtained prior to the submission of this application. If any part of the required information is missing or not complete, the site plan application will not be accepted by the planning department. The applicant shall meet with the staff member in charge of site plan review when the application is ready for submission to insure that all required information is complete. SITE PLAN PACKAGE 1. One set of comment sheets from the following agencies along with any marked copies of the plan: VDOT Co. San. Auth. Inspections Dept. I Fire Marshal Town of Middletown County Engineer City of Winchester Co. Health Dept. Parks & Rec. Airport Authority Town of Stephens City Soil & Water Conser. Dist. 2. One copy of the Site Plan application 3. Four copies of the Site Plan 4. One reproducible copy of the Site Plan (if required) 5. A 35mm slide of the Site Plan (if required) Na