Loading...
HomeMy WebLinkAbout005-94 Parkins Mill Wastewater Treatment Plant-Upgrade - Shaw Dist. - Backfile (2)RECEIPT N"_ 024020 AMOUNT DUE s U I` - AMOUNT PAID $ � � br� 1 DUE BALANCE $ FREL' C ^;;' .. FLANNING AND DEVELOPMENT P. O. bOX 601, 9 ivLn s H iUvuviv oT. WINCHESTER, VIRGINIA 22601 DATE RECEIVED FROM Apr—�------- ADDRESS THE PAID BY ❑ CASH FOR J + ❑- ,HECK ` C ❑ OTHER 9 �A . DOLL� f DAY -TIMERS RE -ORDER No. 3221 — P,inled in USA * STAFF SITE PLAN CHECKLIST * This application is not complete if the following are not included: ,�% U6�1. One set of comment sheets from the following agencies along with any marked / copies of the p plan; VDOT Sanitation Authority Inspections Dept. Fire Marshal County Engineer Airport Authority 4,1742. One copy of the Site Plan application. ✓ 3. Five copies of the Site Plan. City of Winchester Town of Stephens City Town of Middletown l,"-' Health Dept. 4. One reproducible copy of the Site Plan (if required). 5. One 35mm. slide of the Site Plan (if required). TRACKING Date Parks & Recreation Soil & Water Conservation Dist. -V/ 719t Application received. i > / All necessary agency comments received. Fee Paid (amount $ ���� U ) Site Plan to Planning Commission via bi-monthly. is ao Site Plan heard by Planning Commission (if required). Revisions received (if required). Date of approval. R COUNTY of FREDERICI{ Department of Planning and Development 703 / 665-5651 Fax 703 / 678-0682 February 24, 1994 Frederick County Sanitation Authority Attn: Mr. John Whitacre P.O. Box 618 Winchester, Virginia 22604 RE: Parkins Mill Wastewater Treatment Plant Expansion Dear Mr. Whitacre: The Frederick County Planning Department administratively approved Site Plan #005-94 of Parkins Mill Wastewater Treatment Plant on February 22, 1994. The approved site plan calls for the addition of two oxidation ditch structures, two clarifier structures, an ultraviolet and post aeration structure, a preliminary treatment building, a filter building, a new administration building complete with a paved parking area which includes four regular parking spaces, one disabled parking space with appropriate signage, a disabled ramp, concrete wheel stops, and concrete walks, a retaining wall, new chain link fencing, evergreen and deciduous landscaping along West Parkins Mill Road, and all appropriate erosion and sedimentation control measures. I have provided you with two copies of the final site plan. This will enable you to provide the contractor with a copy and keep a copy for your records. Please contact this office to schedule a final inspection of this site once all improvements are complete. Please contact me if I may answer any questions regarding this letter. Sincerely, -&, a. - L?- Evan A. Wyatt Planner II enclosure cc: W. Harrington Smith, Jr., Shawnee District Supervisor T. Roy Jennings, Director of Real Estate Carl W. Lay, Rust Environment & Infrastructure O North 1,0ll( OL111 SU'Cct P.O. 13w, 001 Winchester, VA 22601 Winchestcr. VA 22604 COUNTY OF FREDERICK, VIOINIA DEPARTMENT OF INSPECTIONS Caller . ogo CmPr-R Time Called Date Called I Z 1 9 Phone No. �5� 1i -Z-T+ - I f? Time Requested Date Requested A �Ya� AYJ. Received By Date of Inspection PERMIT HOLDER NAME Rual rst'ohJ comp" RT. NO. Lot No. SEC. No. SUBDIVISION STREET NAME EA-5-1 IL-L RoA°] DIRECTIONS \ `Z) -T-r-, Per b44 ' BUILDING NO. 1 CIO - ow -,G &4+ 5 PLUMBING NO. ►-001Pe tn 0"•) 1��� ELECTRICAL NO. MECHANICAL NO SIGN NO. I DISTRICT ` PERMIT FOR: W`,rC J!{ t ��2. T2C>4-"0 C1..1 Type of Inspection Residential Footers Slab Water Sewer Rough Plumbing Groundworks / Other: Setbacks: FR Draintile Service Rough Electric Rough Mechanical Gas Piping/Test Commercial BK L R Gas Fire -up Final Electrical Framing Final Mechanical Final Site Plan Final Building Fire Marshall Final Plumbing Special/Complaint Time In: In !+ ±!q Temperature 85 F Cut in No. Time Out: 7-7R-u1 Weather SurJ+Jy Results: Approved Comments: Rejected I Signature 1� �J'� Date 1�: FREDERICK COUNTY SANITATION AUTHORITY POST OFFICE BOX 618 WINCHESTER, VA 22604-0618 MEMORANDUM TO: Evan Wyatt FROM: Wellington H. Jones Ph. (540) 665-5690 Fax.(540) 665-6351 SUBJECT: Parkins Mills Wastewater Treatment Plant Expansion DATE: February 13, 1996 ------------------------------------------------------------------------------------------------------------------------------- This will certify that the Frederick County Sanitation Authority will insure the performance of the contractor on the referenced project with regard to site -plan requirements for the completion of the project. The Authority is holding a 5% retainage, as well as performance and payment bonds in the amount of the project to insure the contractor's performance. We currently anticipate the plant will be substantially complete on April 15, 1996. This stage of completion will allow operation of the expanded plant. Final completion of all site work will occur by June 15, 1996. If you have any questions or need additional information, please call me. /ths OFFICE: 199 FRONT ROYAL PIKE WATER AT YOUR SERVICE 6 FEB 1996 RECEIVED OF MMaING COUNTY OF FREDERICK, VIIGNIA DEPARTMENT OF INSPECTIONS Caller Vie. S Time Called I ; '50 6nJ Date Called z Phone No. 6I's) 2.7'F_ 5 318 Time Requested ASAP Date Requested ASAP Received By EVA-,-1 Q • ',/YAK- Date of Inspection z PERMIT HOLDER NAME A'14:Ms I BL1ain4SetJ C&25173,VCT-For, l.oP-.P- RT. NO. Ad!!J Lot No. SEC. No. SUBDIVISION STREET NAME �JKS_r SAIZIe,iK3;& L L_ hOhD DIRECTIONS Qn,"_ s�� -x) BUILDING NO. I D(. `7 PLUMBING NO. S I ­TT7 L0 C.A L'p I ►) So t3 T�"z- ,5—I ELECTRICAL NO Q . lP,-) r4r.1'T o r i MECHANICAL NO. SIGN NO. DISTRICT '5"+ W"ea PERMIT FOR: V/7—P Cy, pMJS 10J Type of Inspection Residential Footers Setbacks: FR Slab Draintile Water Service Sewer Rough Electric Rough Plumbing Groundworks Other: Rough Mechanical Gas Piping/Test Aaftmomal W W-1 P Ao , i -n o f BK I. Gas Fire -up Framing Final Final Building Final Plumbing Time In: �(= 5N� Temperature 0� Cut in No. Time Out: 17 ±2d Weather 4 v 2Q ST" Results: Approved Comments: 0 Rejected R Final Electrical Final Mechanical Site Plan Fire Marshall Special/Complaint rr�� Signature xM t,� - V Date FAX TRANSMISSION FREDERICK COUNTY PLANNING DEPARTMENT 107 NORTH KENT STREET WINCHESTER, VA 2260I (540) 665-5651 Fax: (540) 676-0682 To: John Whitacre Date: Fax #: (540) 665-6351 Pages: From: Evan A. Wyatt Subject: Structure Numbers COMMENTS: June 17, 1996 2, including this cover sheet. 9 40 SITE PLAN APPLICATION Complete the following application: DATE y APPLICATION 1. Development Parkins Mills Wastewater Treatment Plant 2. Location of Property• 158 West Parkins Mill Road (by street name) Winchester, VA 22602 3. Property Owner: Frederick -Winchester Service Authority Address: P. 0. Box 43 Winchester, VA 22604 Telephone: (703) 722-3579 4. Applicant/Agent: Frederick County Sanitation Authority Address: P. 0. Box 618 Winchester, VA 22604 Telephone: (703) 665-5690 5. Designer: Rust Environment & Infrastructure Address: 11240 Waples Mill Road Suite 100 Fairfax, VA 22030 Telephone: (703) 385-3566 Contact: Mr. Carl Lay 6. Is this an original or revised Site Plan? Original Revised x -5- 0 F1 \J 7. Total area of parcel to be developed: 8. Property Information: a) Property ID #: b) Current Zoning: 76-A94A RA 2.60 acres c) Present Use: Wastewater Treatment lant d) Proposed Use: Same (This is a plant upgrade) e) Adjoining Property Zoning: RA f) Adjoining Property Use: Residential/Farming g) Magisterial District: Shawnee I have read the material included in this package and understand what is required by the Frederick County Planning Department. I also understand that all required material will be complete prior to the submissieon,;o my s "te plan. signature: W. H. .YSnes, P.E. Date: February 15, 1994 COUNTY of FREDERICK 1� 11l I rz•I f �l*1 1 1 f February 9, 1994 Frederick County Sanitation Authority Attn: Mr. John Whitacre P.O. Box 618 Winchester, VA 22604 Dear John: Department of Planning and Development 703 / 665-5651 Fax 703 / 678-0682 This letter is to confirm action taken by the Frederick County Board of Zoning Appeals at their meeting of February 8, 1994. Your application #025-93 was approved for a 34' front and a 43' side setback variance for the expansion of the Parkins Mill Wastewater Treatment Plant. This property is located off of Front Royal Pike (Route 522 South) on Route 644, in the Shawnee District, and is identified as PIN 76-A-94A. If you have any questions regarding your variance, please do not hesitate to call this office. Sincerely, W. Wayne Miller Zoning Administrator WWM/s1k cc: Frederick/Winchester Service Authority 1) Norlh l.oulioun SH-CCt P.O. lion 601 Winclicsicr. VA 31-601 Winchcslcr. VA 22004 REQUEST FOR SITE PLAN COMMENTS Frederick County Engineering Department Attn: Director of Engineering P.O. Box 601 Winchester, Virginia 22601 (703) 665-5643 The Frederick County Engineering Department is located at 9 North Loudoun St., 2nd Floor of the Hammon Building in Winchester, if you prefer to hand deliver this review. Applicant's name, address and phone number: Frederick -Winchester Service Authority, P.O. Box 43, Winchester, VA 22604 (703) 722-35, RF- PL/ Agent: Frederick County Sanitation Authority, P.O. Box 618, Winchester, VA 22604 -7' o Name of development and/or description of the request: (703) 665-561 Parkins Mills -Wastewater Treatment Plant Upgrade of plant from 0.5 MGD to 2.0 MGD. Location: 158 West Parkins Mill Road - on SR 644 at intersection with US 522 South. Engineers Comments: I % wU f-I U Engineers S_ignature & Date: (NOTICE TO ENGINEERING DEPT. * LEAS RETURN THIS LICANT.) NOTICE TO APPLICANT It is your responsibility to complete this form as accurately as possible in order to assist the agency with their r..eyew�:;:,;.,Also, please attach two copies of your plans and/or app.,1" i6fi(.,f;6rm. -13- 0 • ocr,z/, 93 REQUEST FOR SITE PLAN COMMENTS Frederick County Inspections Department Attn: Building Official P.O. Box 601 Winchester, Virginia 22601 (703) 665-5650 The Frederick County Inspections Department is located at 9 North Loudoun St., 2nd Floor of the Hammon Building in Winchester, if you prefer to hand deliver this review. Applicant's name, address and phone number: Frederick -Winchester Service Authority, P.O. Box 43, Winchester, VA 22604 (703) 722-35791 `IF-IZ Agent: Frederick County Sanitation Authority, P.O. Box 618, Winchester, VA ?a Name of development and/or description of the request: Parkins Mills Wastewater Treatment Plant Upgrade of plant from 0.5 MGD to 2.0 MGD. Location: 158 West Parkins Mill Road - on SR 644 at intersection with US 522 South. 22604 703) 665-5690 Inspection Department Comments: Building shall comply with Virginia Uniform Statewide Building Code and Section 305. Use Group F (facto and industrial) for the Treatment Plant of the BOCA National Building Code/1990 and Section 303 Use Group B (business) for the Administration Building. Other codes that apply are title 28 Code of Federal Regulation, Part 36 Nondiscrimination on the Basis of Diability by Public Accommodation�in Commercial Facilities. Use Group U, utility and miscellaneous for all otter structures. Code Administrator Signature & Date: (NOTICE TO INSPECTIONS DEPT.*PLEASE NOTICE TO APPLICANT It is your responsibility to complete this form possible in order to assist the agency with thei: please attach a copy of your plans and/or applica TO JAPPLICAXT. -14- �JJREQUEST FOR SITE PLAN COMMENTS LORD FAIRFAX SOIL i WATER CONSERVATION DISTRICT 2045-B Valley Avenue Winchester, Va. 22601 (703) 662-3312 The Soil and Water Conservation Office is located at 2045-B Valley Ave in Winchester, if you prefer to hand deliver this review form. Applicant's name, address and phone number: Frederick -Winchester Service Authority, P.O. Box 43, Winchester, VA 22604 (703) 722-357� REPLY Agent: Frederick County Sanitation Authority, P.O. Box 618, Winchester, VA 22604 7'0 703 665-569( Name of development and/or description of the request: Parkins Mills Wastewater Treatment Plant Upgrade of plant from 0.5 MGD to 2.0 MGD. r _ Location: 158 West Parkins Mill Road - on SR 644 at intersection with US 522 South. soil and Water Conservation Comments: C-219r Signature & Dates �, (NOTICE - PLEASg/RETURN THIS YO TOT E APPLICANT/) NOTICE TO APPLICANT It is your responsibility to complete this form as accurately as possible in order to assist the agency with their review..,.,,, Also, please attach a copy of your plans and/or application-ii�' .or i eta • .�:�..� -20- 0 0 REQUEST FOR SITE PLAN COMMENTS Frederick -Winchester Health Department Attn: Sanitation Engineer P.O. Box 2056 Winchester, Virginia 22601 (703) 722-3480 acra/, !3 ;1 VOV 1993 The Frederick -Winchester Health Department is located at the intersection of Smithfield Avenue and Brick Kiln Road, if you prefer to hand deliver this review form Applicant's name, address and phone number: Frederick -Winchester Service Authority, P.O. Box 43, Winchester, VA 22604 (703) 722-3579 1 Agent: Frederick County Sanitation Authority, P.O. Box 618, Winchester, VA 22604 Name of development and/or description of the request: (703) 665-5690 Parkins Mills Wastewater Treatment Plant lipgrade of plant from 0.5 MGD to 2.0 MGD Location: 158 West Parkins Mill Road - on SR 644 at intersection with US 522 South. Health Department Comments: Health Signature and Date: ,,�, �2" GOZ0- (NOTICE TO HEALTH DEPT. - PLEASE)gETURN T IS F 7 NOTICE TO APPLICANT It is your responsibility to complete this form as possible in order to assist the agency with their please attach a copy of your plans and/or applicati 0GY ]993 ,c� 3 APPLICANT.) C accurately '17 review �n forb.l�`'�•'`��c4 I "I" "' C:) I= FF� E : l l E-, R I Cl* P': ;, ' '' :I: E � [a 1: Id :C t FEE : I'`'IA R iG 1.1r 11.... ` ,3, Cal= E= :E t...r')1\1I') D E: V E::,!I....Cl `1'°IE:_NT CI' 0IvI[l I'l'T' : . . 2 2 r ,.., . 5� ., a , !•:_ (t �_; !. !:_ .1. !::. 1 1(.: c...,__ , ,.., 1., •...1 t, ,::.: (•� 1::: 5' :t. i:r. t'J i:•_ r::1 ('•1. .. _ 1••i I::) I:) .. 1 !:_ ::3 Y"i '�� : � tl't,�? I = 1'- i'•:':` is i t=d I...:f. i� (•�: t. , i � t..t 1"t �., ;.'' ,.., ,�t 1"t :t. 't:::1 '1:, :1. t :,1"i t •) l..( t, l t t. i y...:l..t.. `,.'' A d (A )' i ' a'-� I'-' „ 0 :. B i - ,.; fit.) 1 t t'i7.1"ti tli'?45't:t?1' , t"I"l 2c'6t:i4 .......... ..... ........................... __................................................ _.._........................................... _...... _........... _........................................................... _......... ........ _.... .... F." i... t:` A i:3 i 't, 1'd;:?.;n (:2 f.":L :::t n 't; 1-'t'Ii: rie No . I t_!,:] 66-)5..._569t_) V l::) ii? r .. (..) i::,'i' r-1p . 7. i :: ��....:1. is l 1"iii ;.':; 1 't; i.? )... )._ i' 11 . t �qqtq'! 1"1 J. 1"} 1-a ' ).:::t 1"1 .. l.t 1" .1.::, t, E t..t c f'' i 1 !" (.a l t -.-.i :`t..� t_t i'•'a �'l` . 1 .. l .L 1. e C: t 7. i_t t"i D i -_:-it I--- :*i. i _ '%, 6 h za ,,4 n t���` e ... ..t 1. iE••. �� �...17..a i,.FN 1• %) .. .. :1.1. t) .1.': 21 1 p Y"' 1 1"i I•:: L e i"' System 4 r'� e s i i.i e i i t i t :I. S p r i Y'i l•::1. e y_. B ,;; ,^.. _ e tt.) F .(. )... ir:: t:..y I .={ 1... ft.} x ., ... _... :'_ iil l:? i"' � 3 i-? t'l i= `.1 '3' t.:1 1 :1. t.::.i. �:? t=71=� i; l-?'=:i':.i . f••1t..t!.:.t.+_.tc:1 _i:.:. ,. :.: _ % ii..lF:.:Ilt7.'f-J.f'ii . ` � ` h � 1'l ale C i:` t:) k? 1�1 t::l , "' :C }... ;ir. .._ a1 i"t `W.: a E;!:;. 67 t_l 1 )' is !_I y y t:....o No o x ..................... _....... __............. ............ E, i:? :::1 i::l +,°J ; •7. `�' :' i=t 1 '�:s 1. !`�:.` t'J •=:� `�:' t'�i 1 !:� �; l"i '::a f^Ii::lt:_`i::li..ic1't:i. x 3:1"t.i:li:li•:)l:lt..t<?.'t:L! kli?'t: _......... ...... ........... .............................. Special 1"'Ic1 i.. c:1 Y t..l'c:i I', i:! ?: ii?t'1 [{ Y e':i No 1t. t. , i:? III t7t e-2 n 't: a• Frederick County Sanitation Au*ity Post Office Box 618 WINCHESTER, VIRGINIA 22601 Phone 665-5690 To /45r,0165f lck C'00/Y7 �G/,��YiyliY� ICE T 0 13OX 6o/ W-///Vc��s z; !</. > WE ARE SENDING YOU Rr"Attached ❑ Under separate cover via Lr_`T`VF[R*1F'TRUSENUML DATE�� /� �� JOB NO. ATTENTION ❑ Shop drawings ❑ Prints ❑ Plans ❑ Samples ❑ Copy of letter ❑ Change order ❑ the following items: ❑ Specifications COPIES DATE NO. DESCRIPTION cC,i11 FiivT Sh�F�'T F /3G4 G S /TAT/oy F,.�YL-l�Yf�' c�F�k�a/� 60.00 THESE ARE TRANSMITTED as checked below: ❑ For approval IK For your use > ❑ As requested ❑ For review and comment ❑ FOR BIDS DUE ❑ Approved as submitted ❑ Approved as noted ❑ Returned for corrections 19 ❑ Resubmit copies for approval ❑ Submit copies for distribution ❑ Return corrected prints ❑ PRINTS RETURNED AFTER LOAN TO US REMARKS 60A S/ TF COPY PRODUCT240 Inc., Groton, Mau. 01471. SIGNED: If enclosures are not as noted, kindly if us at once. 0 0 MEMORANDUM TO: File FROM: Neil Weinstein RE: Parkins Mill WWTP, REI #19656 SUBJECT: Sediment and Erosion Control Plans Mr. Hepner of the SCD informed me that the plans were approved contingent upon reciept of the Sediment and Erosion Control Narrative and Calulations. These were forwarded to him during the first week of December 1993. No additional or subsequent revisions or information was requested. • COUNTY of FREDERICK Harvey E. Strawsnyder, Jr., P.E. Director of Engineering & Inspections 703'665-5643 FAX: 703 678-0682 August 7, 1992 Mr. Wellington Jones, P.E. Frederick County Sanitation Authority P.O. Box 618 Winchester, Virginia 22601 RE: Flood Plain Study Parkins Mill Plant Expansion Dear Wendy: We have completed our review of the flood plain study prepared by Donohue and Associates for the proposed Parkins Mill Plant expansion. Basically, Donohue routed the 100 year storm event through the Opequon Creek adjacent to the proposed expansion. Based on this routing and corresponding analysis, they determined that the proposed fill would increase the water surface elevation of the 100 year flood a maximum of 0.77 feet. This maximum occurs immediately adjacent to the proposed fill expansion. There is no increase at the Route 522 South bridge which is located approximately 750 feet upstream of the proposed expansion. Based on our review, we conclude that the proposed expansion will have an insignificant impact on the 100 year flood level. Therefore, we recommend approval of the proposed expansion scheme. Submittal and approval of the final design documents will be required prior to construction. Sincerely, Harvey Strawsnyde , Jr., P.E. Direct of Engineering and Inspections HES:rls cc: file 9 North Loudoun St. - P.O. Box 601 - Winchester. Virginia - 22604.- CHAPTER 11 FLOOD PLAIN AND WETLANDS ASSESSMENT The objective of the floodplain assessment was to determine if fill could take place within the floodplain to accommodate the expanded facilities. The Frederick County Sanitation Authority and Donohue & Associates modified the original agreement to investigate this option. The scope of services were as follows : (a) Hydrologic Evaluation : Determine predicted flow rates for the 100 year storm event for critical cross sections along the floodplain in the study area. The flow rate will be determined for planned land use projections based on the County's Comprehensive Plan. (b) Hydraulic Evaluation Establish water surface elevations based on existing channel conditions, for a 100 year storm event. Establish water surface elevations for modified cross sections, as a result of proposed plant upgrades under the same flow rates as determined for the 100 yr. storm. The flood plain analysis was done for the placement of proposed facilities as shown in Figure 5. The Opequon - Stephens Run area was divided into 4 drainage basins. The hydrologic flows to the 91 • Opequon were calculated with the HEC1 computer model. After the calculation of hydrologic flows, hydraulic analysis was performed using the HEC2 computer model to determine the effect of the proposed structures on the 100 year flood plain. It was assumed that the distance between the existing and proposed oxidation ditches was 40 feet with 5 foot space on the south side of the proposed ditches. It may be possible to provide a 10 foot road on the south side of the proposed ditches, by reducing the distance between the oxidation ditches to 351. The details of the exact distance can be worked out during the design phase. A 2 (H):1 (V) slope was assumed for analysis purposes. Based on the above assumptions, the results of the hydraulic analysis are summarized in Table 20. As can be observed from the table, the maximum change in water surface elevation was 0.77 feet at cross - section 10 (Figure 8). Hence construction of the proposed facilities as shown in Figures 5 and 6 is possible without raising the 100 year flood plain by more than a foot. Wetland studies were performed to determine if there are any wetlands that may be affected by the construction of the treatment plant. The US Army Corps of Engineers and EPA have defined wetlands as "areas that are inundated or saturated by surface or groundwater at a frequency and duration sufficient to support and that, under normal circumstances, do support a prevalence of vcWtpLtipn typically adapted for life in saturated soil 92 • 0 conditions". The wetlands study was carried out by the Frederick county Planning Department. Based on the engineer's assessment, there are no wetlands in the Parkins Mill area. 93 0 0 Cross Sections 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 1501.0 1502.0 16.0 17.0 18.0 TABLE 20 SUMMARY OF WATER SURFACE LEVELS PARKINS MILL WASTEWATER TREATMENT FACILITY Existing Condition Water Surface Level 622.89 624.92 627.15 626.67 627.00 627.33 627.53 627.59 627.75 627.81 627.89 628.38 628.78 628.20 628.51 633.06 635.17 637.35 637.83 637.57 Proposed Changes Water Surface Level 622.89 624.92 627.15 626.67 626.66 627.00 627.22 627.36 627.78 628.58 628.59 629.14 629.26 628.62 628.85 633.06 635.17 637.35 637.83 637.57 Total Change Water Surface Level -0.34 -0.33 -0.31 -0.23 0.03 0.77 0.70 0.76 0.48 0.42 0.34 9 10 Cross Sections 19.0 20.0 21.0 22.0 101.0 102.0 103.0 104.0 105.0 1051.0 1052.0 1053.0 1054.0 106.0 107.0 108.0 R/AM5 Existing Condition Water Surface Leve 637.13 638.81 638.76 638.67 629.35 629.14 629.32 630.17 630.82 632.08 636.76 637.14 636.30 638.71 638.71 638.70 Table 20 (Continued) Proposed Changes Water Surface Level 637.13 638.81 638.76 638.67 629.60 629.41 629.55 630.24 630.81 631.97 636.78 637.14 636.30 638.71 638.71 638.70 Total Change Water Surface Level 0.25 0.27 0.23 0.07 -0.01 -0.11 0.02 0 i MENENVIRONMENT & INFRASTRUCTURE Formerly SEC Donohue February 2, 1994 Mr. Evan Wyatt Planner County of Frederick 9 North Loudoun Street P.O. Box 601 Winchester, Virginia ` !0 RUST Environment & Infrastructure Inc. 1 11240 Waples viill Road, Suite 100 Fairfax, VA 22030 (703) 385-3566 • FAX (703) 385-8319 LT ` t c �FIU Re: Parkins Mills Wastewater Treatment Plant Plan Preliminary Site Plan Review RUST E&I Project No. 19656 Dear Evan: The following responds to the comments contained in your November 30, 1993 letter to John Whitacre. Some of the information you have requested was shown on the construction plan sheets other than the site plan you were provided. Those sheets are included with this correspondence along with Sheets 02-CF-1 and 02-C-2. GENERAL INFORMATION 1. Name and address of the owner is shown on the cover sheet and the civil site plan (Sheet 02-CF-1). 2. Name, address and telephone number of the designer is shown on the cover sheet and Sheet 02-CF-1. 3. Signed certificate of the designer (professional engineer stamp) is on each individual sheet of the plan set. 4. A signature block for the Zoning Administrator has been added to Sheet 02-CF-1. 5. The location map for the area is included on Sheet 01-G-3. 6. The Shawnee Magisterial District is Note #4 on Sheet 02-CF-1. 7. The site zoning is shown as Note #3 on Sheet 02-CF-1. 8. The zoning and use of adjoining properties is shown as Note #3 on Sheet 02-CF-1. Qttrality through teamworle 0 0 Mr. Evan Wyatt February 2, 1994 Page 2 9. The property description (metes and bounds) is shown on Sheet 02-CF-1. This information was taken from the existing deed. 10. The site acreage, 6.7328 acres, is shown on Sheet 02-CF-1. 11. Location and dimension of setbacks for proposed structures is shown on Sheet 02- CF-1. 12. The height of all structures is shown on Sheet 02-CF-1. 13. The name of Route 644, West Parkins Mills Road, is shown on Sheet 02-CF-1. SPECIFIC INFORMATION 1. The site plan has been modified to provide more detail on the parking spaces. Parking lot calculations and parking space locations are indicated on Sheet 02-CF-1. 2. The modifications to the 100-year floodplain are shown on the site plan. The floodplain analysis has been reviewed and approved by Ed Strawsnyder, P.E., Director of Public Works. SPECIFIC CONCERNS 1. The zoning variance application has been developed by the Frederick County Sanitation Authority. We expect the variance to be approved at the February 8, 1994 meeting. A note has been added to Sheet 02-CF-1 to reflect the variance. CHECKLIST COMMENTS 2. See General Information. 3. of it ff 4. it of it 5. 8. of 9. it 10. 13. 14. 15. P 0 Mr. Evan Wyatt February 2, 1994 Page 3 16. See General Information. 17. 22. 24. See Sheet 02-CE-9. 25. See Sheet 02-CF-1. 29. Not required for site. 34. See Sheet 02-CP-3 and 02-CP-4 for location of utilities. 36. Site provides adequate access for fire fighting requirements. Nearest fire hydrant located on U.S. 522, 100' northwest of the entrance to Parkins Mills Road. 37. See General Information. 38. it 39. it If you have additional questions, please give me a call. Sincerely, W L. � Carl W. Lay, P.E. Project Manager Enclosures: Parkins Mills WWTP Plan Sheets 1. Cover Sheet 2. Civil Site Plan, 02-CF-1 3. Vicinity and Location Detail, 01-G-3 4. Electrical Site Plan, 02-CE-9 5. Yard Piping 02-CP-3 6. Piping Plan 02-CP-4 7. Erosion and Sediment Control Plan 02-C-2 cc: John Whitacre, P.E. Frederick County Sanitation Authority • 0 COUNTY of FREDERICK Department of Planning and Development 703 / 665-5651 Fax 703/678-0682 November 30, 1993 Frederick County Sanitation Authority Attn: John Whitacre P.O. Box 618 Winchester, Virginia 22604 RE: Parkins Mill Wastewater Treatment Plant Preliminary Site Plan Review Dear John: I have completed my review of the above referenced site plan. Please have Mr. Lay revise the site plan to address the following comments: GENERAL INFORMATION 1) Name and address of the owner/developer. 2) Name address and telephone number of the designer. 3) Signed certificate of the designer. 4) A signature block for the Zoning Administrator. 5) A location map for this area. 6) The Magisterial District for this site (Shawnee). 7) The zoning of this site (RA). 8) The zoning and use of adjoining properties. 9) The metes and bounds description for this property. 10) The acreage for the site. 11) The location and dimension of setbacks for the proposed structures. 12) The height of all structures. 13) The name of Route 644 (West Parkins Mill Road). SPECIFIC INFORMATION 1) The site plan indicates that there is an area in front of the proposed administration building that will be partially paved and partially graveled. I believe that this area will be used for parking. The site plan needs to depict this area in more detail. The site plan should provide parking lot calculations (1 space per 250 feet of floor area), and indicate where the parking spaces will be located. The area for the parking lot needs to be paved, and the parking spaces need to be striped. 9 North Loudoun Strcct P.O. Box 601 Winchester, VA 22601 Winchester, VA 22604 0 0 Page -2- Whitacre Letter November 30, 1993 2) Information regarding the modification to the flood plain needs to be submitted with the other site plan material. I believe that this information has been reviewed and approved by Mr. H.E. Strawsnyder, Director of Public Works. This will allow our department to maintain an accurate file for this project. SPECIFIC CONCERNS 1) The proposed development is located on property that is zoned RA (Rural Areas). This requires a 60 foot setback from West Parkins Mill Road and a 50 foot setback from the side and rear property lines. I discussed this issue with Wellington Jones, and he indicated that your department would like to apply for a variance to the required 50 setback. The ultraviolet and post aeration structure is located six feet from the rear property line; therefore, you will be applying for a 44 foot setback variance. The variance applications are maintained in our office. I will be available to assist you with any questions you may have regarding- this application. The Planning Commission and Board of Supervisors have provided our. department with administrative approval authority for this site plan. Please have Mr. Lay revise the site plan to incorporate my comments. Our department will need five copies of the final site plan (drawing number sheets 02-CF-1 & 02-C-2), all approved review agency comments, the site plan application page, and the appropriate review fee. Once our department has received these items. I will recommend final approval for this site plan. Please contact me if I may answer any questions regarding this letter, or if I may be of further assistance. Sincerely, L-'� �' - J�V- Evan A. Wyatt Planner II I cc: Carl Lay, Rust Environment & Infrastructure t A J \ nn 19, 3 G F - I APPLICANT'S CHECKLIST Your site plan should include the following: Administrative Information 1. Name of proposed development 2. Name and address of owner — ✓ 3. Name and address of developer _ 4. Name, address, and phone number of designer _ 5. Certificate of surveyor, engineer, or architect _ 6. Date plan prepared and date of revisions [tA 7. A listing of all conditions placed on the site as a result of a conditional use permit or conditional zoning approval — ✓ .8. A space labeled "approved by the Zoning Administrator" for the approval signature and date of approval General Site Information Y N / 9. Location map (scale 1:2000) 10. Magisterial District of site V _ 11. Scale of site plan (not to exceed 1:50) 12. North Arrow 13. Zoning of site 14. Use and zoning of adjoining properties Lots/Uses/Buildings & Structures Y N 15. Surveyed boundaries for all lots and parcels 16. Acreage of all lots included in the plan _ ,/ 17. The location and dimensions of all required setbacks and yard areas 18. Location of all buildings, structures, and uses _ 19. The proposed use of each building, structure, and area _ t/A 20. The location and type of all dwelling units 21. Ground floor area and total floor area of all buildings with FAR calculations for commercial and industrial zoning districts 22. The height of all buildings and structures 23. The location and dimension of all signs 7 Lots/Uses/Buildings & Structures (con't Y N Pj24. Location of outdoor lighting fixtures Location and nature of outdoor storage areas Location and area of common open space _h�/A 27. Location and description of all recreation facilities _ 28. Location of sidewalks and pedestrian ways 29. Location of outdoor trash receptacles Roads Y N — 30 Name and number of existing and planned streets on and adjoining the site 31. Location of existing and planned streets on and adjoining the site _ WA 32. Dimensions, boundaries, width, pavement, and construction of planned roads _ 33. Location and dimensions of all proposed entrances from public right-of-ways Utilities Y N/ ✓ 34. Location of all utilities, including sewer and water lines with the size of lines, mains, and laterals 35. Location and width of all easements, including access, utility and drainage easements _ 36 Location and nature of fire lanes, fire hydrants, and all other facilities necessary to meet the Fire Le. Code requirements Parking 10 ( %e�Z,ov�c� Y N _ ✓ 37 Calculations describing the required number of ✓ 38 parking and loading spaces _ Location and dimensions of all parking and loading spaces, driveways, parking aisles, curbing, and / 39. other features to be used — �/ Location and dimension of all handicapped spaces E3 Natural Features Y N _ 40. Existing and finished contour lines 7 _ 41. Location of steep slopes, woodlands, floodplains, wetlands, sinkholes, and other environmental — features 42. Location of streams and drainage ways Landscaping Y N _ 43. Landscaping plan describing location and types of plants to be used 44. Location of required buffers and screening with cross sections or profiles Erosion and Sediment Control Y N 45. A stormwater management plan with run off calculations and location and description of facilities to be used 46. Soil erosion and sedimentation control plan with location, types, and examples of provisions to be used 9 100 100 es es EXISTING .. OX. DITCH �60 CONTOUR LINE 100�� EX. 100 YEAR FLOOD PLAIN GRAPHIC C�4LE soo ISO A)o 12DO w m., g 1% ....../ 560 00 3? EX. 622.89 P PROP. 622.89 I i Z Q� J I— CL Z 0 W Ow O> QCL 00 � �W..,�J W LJ J !�O O V r— a- !i O Z Wfl-ct� U Q. Z O O Z I— CY X a W O