Loading...
HomeMy WebLinkAbout63-22 Site PlanCOVER SHEET01 C-GI-001.DWG C-GI-001 SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-GI-001.DWG, 5/23/2023 10:30 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 PROJECT AREA SITE ENTRANCE 310 TYSON DRIVE LOADING DOCK EXPANSION 310 TYSON DRIVE WINCHESTER, VA GAINESBORO MAGISTERIAL DISTRICT FREDERICK COUNTY PIN # 43-19-31 SP #63-22 VICINITY MAP (SCALE 1" = 300') SHEET INDEX SHEET NO.SHEET TITLE 01 COVER SHEET 02 GENERAL NOTES, ABBREVIATIONS, AND LEGEND 03 EXISTING CONDITIONS 04 DEMOLITION PLAN 05 SITE PLAN 06 DIMENSIONING AND JOINT LAYOUT PLAN 07 GRADING AND DRAINAGE PLAN 08 UTILITY PLAN 09 WATER MAIN PROFILE AND UTILITY DETAILS 10 STORM SEWER PROFILE AND COMPUTATIONS 11 UTILITY DETAILS 12 SITE DETAILS 13 SITE DETAILS 14 SITE DETAILS 15 SITE DETAILS 16 EROSION AND SEDIMENT CONTROL NOTES 17 EROSION AND SEDIMENT CONTROL PLAN PHASE 1 18 EROSION AND SEDIMENT CONTROL PLAN PHASE 2 19 EROSION AND SEDIMENT CONTROL DETAILS 20 ADEQUATE OUTFALL ANALYSIS 21 LANDSCAPE PLAN OVERALL 22 LANDSCAPE PLAN 1 23 LANDSCAPE PLAN 2 24 LANDSCAPE COMPUTATIONS PROJECT DIRECTORY: PANNING & DEVELOPMENT 107 NORTH KENT STREET SUITE 202 WINCHESTER, VA 22601 540-665-5651 WATER AND SEWER WINCHESTER PUBLIC UTILITIES 15 NORTH CAMERON STREET WINCHESTER, VA 22601 540-667-1815 FREDERICK WATER 315 TASKER ROAD STEPHENS CITY, VA 22655 540-868-1429 ENGINEER: GORDON US LLC ADDRESS: 4501 DALY DRIVE, SUITE 200 CHANTILLY, VIRGINIA 20151 PHONE: 703-263-7989 CONTACT: CHRIS KINGSLAND, SENIOR PROJECT MANAGER EMAIL: CKINGSLAND@GORDON.US.COM DEVELOPER: LINCOLN PROPERTY COMPANY ADDRESS: 1530 WILSON BOULEVARD SUITE 200 ARLINGTON, VA 22209 PHONE: 703-284-3344 CONTACT: CHRIS COX, CONSTRUCTION MANAGER EMAIL: CCOX@LPC.COM OWNER: RBG TYSON ASSOCIATES LLC C/O RBG HOLDINGS LLC ADDRESS: 1100 WILSON BOULEVARD SUITE 210 ARLINGTON, VA 22209 PHONE: 202-839-3600 M C G H E E R O A D TYSON DRIVEMCGHEE ROADPROJECT DESCRIPTION: THE EXISTING USE OF THE PROPERTY IS WAREHOUSING AND OFFICE SPACE WITH MULTIPLE LOADING DOCKS ALONG THE SOUTH WESTERN PORTION OF THE BUILDING. THIS PROJECT IS PROPOSING A LOADING DOCK ADDITION, INCLUDING A DRIVE IN RAMP, AND THE RELOCATION OF STORM DRAINS AND FIRE HYDRANTS AT THE BACK OF THE BUILDING. NO CHANGE TO THE EXISTING USE IS PROPOSED. PLAN REFERENCES: PREVIOUSLY APPROVED PLANS: VALLEY HEALTH EPIC TRAINING CENTER (SP #26-13) SP #33-87, SP #02-96, SP #20-98, SP #20-15 SITE TABULATIONS: ZONING: M-1 LIGHT INDUSTRIAL ADJACENT ZONING: ALL USES WITHIN 500 FEET ARE ZONED M-1 LIGHT INDUSTRIAL LAND USE: WAREHOUSING AND OFFICE (SIC - 49) SITE AREA: EXISTING TOTAL AREA OF SITE = 653,400 SF OR 15.00 AC PROPOSED DEVELOPMENT AREA = 25,963 SF OR 0.60 AC DIMENSIONAL REQUIREMENTS: FRONT YARD SETBACK = 75 FT SIDE YARD SETBACK = 25 FT REAR YARD SETBACK = 25 FT HEIGHT LIMIT: MAXIMUM HEIGHT = 60 FT BUILDING HEIGHT = 28.5 FT AREA REQUIREMENTS: TOTAL GROUND FLOOR AREA = 226,730 SF TOTAL LOT AREA = 653,400 SF PROPOSED GROUND FLOOR AREA = 230,980 SF MAX FLOOR AREA TO LOT AREA RATIO (FAR) = 1.0 PROPOSED FAR = 0.35 MINIMUM LANDSCAPED AREA = 25% IMPERVIOUS AREAS: EXISTING IMPERVIOUS AREA = 35,593 SF OR 0.82 AC PROPOSED IMPERVIOUS AREA = 39,511 SF OR 0.91 AC PROPOSED IMPERVIOUS AREA REQUIRING TREATMENT = 3,918 SF OR 0.09 AC PARKING TABULATION: ZONING ANALYSIS -FOR 201 TO 300 TOTAL SPACES, 7 ADA PARKING SPACES ARE REQUIRED WITH A MINIMUM OF 2 VAN SPACES -PER FREDERICK COUNTY ZONING REQUIREMENTS 1.5 SPACES PER WAREHOUSE EMPLOYEE 1 SPACE PER 250 SQUARE FEET OF OFFICE FLOOR AREA 1 SPACE FOR EACH COMPANY VEHICLE AND EQUIPMENT STORED OUTSIDE TABULATION -WAREHOUSE EMPLOYEE TOTAL = 80 + 21 = 101 EMPLOYEES 152 PARKING SPACES -OFFICE SPACE TOTAL = 6,888 SF + 6,168 SF = 13,056 SF 53 PARKING SPACES COMPLIANCE (SEE TABLE) -205 TOTAL PARKING SPACES REQUIRED 198 STANDARD PARKING SPACES PROVIDED -7 ADA SPACES REQUIRED (2 VAN) 3 ADA SPACES PROVIDED IN THE REAR AND 4 IN THE FRONT FOR A TOTAL OF 7 APPROVED BY THE FREDERICK COUNTY ZONING ADMINISTRATOR SIGNATURE DATE SITE PLAN VALID FOR FIVE (5) YEARS FROM APPROVAL DATELOCATION MAP (SCALE 1" = 1000') PROJECT SITE RESPONSIBLE LAND DISTURBER NAME:______________________________________________________ CERTIFICATION #: ____________________________________________ DATE:______________________________________________________ THE RESPONSIBLE LAND DISTURBER IS THAT PARTY RESPONSIBLE FOR CARRYING OUT THE LAND DISTURBING ACTIVITY AS SET FORTH IN THE PLANS. GENERAL NOTES, ABBREVIATIONS, AND LEGEND02 C-GI-002.DWG C-GI-002 SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-GI-002.DWG, 5/23/2023 10:30 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 MH MANHOLE MI MILE MS MEDIAN STRIP MSL MEAN SEA LEVEL MON MONUMENT N/F NOW OR FORMERLY NCA NATIONAL CEMETERY ADMINISTRATION NIC NOT IN CONTRACT NFA NET FLOOR AREA NO, #NUMBER NBL NORTH BOUND LANE OC ON CENTER OC OVERHEAD COMMUNICATIONS OD OUTSIDE DIAMETER OE OVERHEAD ELECTRIC OH OVERHANG P PERIMETER PC POINT OF CURVATURE PCC POINT OF COMPOUND CURVE PCEP POINT OF CURVE, EDGE OF PAVEMENT PCTC POINT OF CURVE, TOP OF CURB PD PAVEMENT DRAIN PERF PERFORATED PG PAGE PGL POINT OF GRADE LINE PH PROFILE HOLE PI POINT OF INTERSECTION PL PROPERTY LINE POV PRIVATELY OWNED VEHICLE PRC POINT OF REVERSE CURVE PRELIMPRELIMINARY PROP PROPOSED PT POINT OF TANGENCY PVC POINT OF VERTICAL CURVATURE PVC POLY VINYL CHLORIDE (PLASTIC PIPE) PVI POINT OF VERTICAL INTERSECTION PVMT PAVEMENT PVT POINT OF VERTICAL TANGENCY P&P PLAN AND PROFILE Q FLOW, AMOUNT OF RUNOFF R RISER, RADIUS R&CAPREBAR W/ A CAP RCP REINFORCED CONCRETE PIPE RD ROAD, ROOF DRAIN RDM RAPID DRAINAGE MATERIAL RW RETAINING WALL REV REVISION RGP ROUGH GRADING PLAN RR RAILROAD RTE ROUTE RT RIGHT R/W RIGHT OF WAY SAN SANITARY SBL SOUTH BOUND LANE SEC SECTION SEW SEWER SP SITE PLAN SPEC SPECIFICATION STA STATION STE STEAM STD STANDARD STK STACK STM STORM SVC SERVICE S/W SIDEWALK Sx CROSS SLOPE T TANGENT TB TEST BORE TC TOP OF CURB TCP TERRA COTTA PIPE TELE TELEPHONE TH TEST HOLE TP TEST PIT TB TOP OF BANK TW TOP OF WALL UC UNDERGROUND COMMUNICATIONS UD UNDERDRAIN UGE UNDERGROUND ELECTRIC U/G UNDERGROUND UL UPPER LEVEL UP UTILITY POLE V VELOCITY VCP VITRIFIED CLAY PIPE VF VERTICAL FOOT W WATER W/M WATERMAIN W.M.WATER METER WSE WATER SURFACE ELEVATION WBL WEST BOUND LANE X-ING CROSSING YI YARD INLET YR YEAR Z SIDE SLOPES A AREA OR ARC AC ACRE AE ABOVE GROUND ELECTRIC AGEC ABOVE GROUND ELECTRIC CONDUIT ANSI AMERICAN NATIONAL STANDARDS INSTITUTE APPROX APPROXIMATE ARCH ARCHITECTURAL ASPH ASPHALT BC BOTTOM OF CURB BF BASEMENT FLOOR BL BASE LINE BLDG BUILDING BM BENCHMARK BOV BLOW OFF VALVE BRL BUILDING RESTRICTION LINE BW BOTTOM OF WALL C COEFFICIENT OF RUNOFF CB CATCH BASIN OR CHORD BEARING CC CENTER TO CENTER CFS CUBIC FEET PER SECOND CHD CHORD CG CURB AND GUTTER CIP CAST IRON PIPE CL CENTERLINE CMP CORRUGATED METAL PIPE CONC CONCRETE CO CLEAN OUT COMM COMMUNICATIONS CONN CONNECTION CON CONTAMINATED CONT CONTINUATION COR CONTRACTING OFFICERS REPRESENTATIVE CT COURT D DEPTH DB DEED BOOK DET DETAIL DGA DENSE GRADED AGGREGATE DI DROP INLET DIP DUCTILE IRON PIPE DM DROP MANHOLE DOM DOMESTIC DR DRIVE DWG DRAWING D/W DRIVEWAY D DELTA EC EDGE OF CONCRETE ESMT EASEMENT EG EDGE OF GUTTER ELEV ELEVATION EP EDGE OF PAVEMENT ES END SECTION EW END WALL EXP EXPANSION EX EXISTING ELEC ELECTRICAL EBL EAST BOUND LANE FAR FLOOR AREA RATIO FC FACE OF CURB FD FOUNDATION DRAIN FF FIRST FLOOR OR FINISHED FLOOR FG FINISHED GRADE FH FIRE HYDRANT FP FLOOD PLAIN FR FROM G GAS GFA GROSS FLOOR AREA GR GRADE GR GUARD RAIL HC HANDICAP HERCP HORIZONTAL ELLIPTICAL REINFORCED CONCRETE PIPE HGL HYDRAULIC GRADE LINE HP HIGH POINT HR HAND RAIL HT HEIGHT HWSR HOT WATER SUPPLY & RETURN I RAINFALL INTENSITY ID INSIDE DIAMETER IN INCH INV INVERT IP IRON PIPE IPF IRON PIPE FOUND IPS IRON PIPE SET JB JUNCTION BOX K ONE THOUSAND (KILO) L LENGTH LAT LATERAL LL LOWER LEVEL LOC LOCATION LP LOW POINT LT LEFT MAT MATERIAL MECH MECHANICAL MEP MECHANICAL, ELECTRICAL, PLUMBING OHE TEL BX C RD LEGEND W LOW LOC Wx 724 724 +24 00X 24.00 GENERAL NOTES 1.THIS PROJECT PROPOSED ADDING A 4-FOOT TALL LOADING DOCK FOR MULTIPLE TRUCK BAYS AND DRIVE-IN RAMPS ON THE WEST SIDE OF THE EXISTING BUILDING. THIS WILL REQUIRE A RECONFIGURATION OF THE EXISTING PARKING AT THE BACK OF THE BUILDING, RELOCATED ADA PARKING, STORMWATER STRUCTURES, AND FIRE HYDRANT LOCATIONS. 2.THE PROPERTY IS LOCATED IN FREDERICK COUNTY, VA, IDENTIFIED AS SHOWN ON THE FREDERICK COUNTY TAX MAP AS PIN NUMBER 43-19-31. 3.THE PROPERTY IS ZONED M-1 LIGHT INDUSTRIAL, THE EXISTING USE IS A WAREHOUSING AND OFFICE. 4.THE PROPERTY CONSISTS OF 653,400 SQUARE FEET OR 15.00 ACRES. 5.DISTURBED AREA FOR THE PROJECT IS APPROXIMATELY 0.60 ACRES OR 25,963 SF. 6.TO THE BEST OF OUR KNOWLEDGE AND BELIEF, THERE IS NO EVIDENCE OF ANY GRAVE, OBJECT OR STRUCTURE MARKING A PLACE OF BURIAL ON THIS PROPERTY. 7.TO THE BEST OF OUR KNOWLEDGE AND BELIEF, THERE IS NO EVIDENCE OF ANY HISTORIC SITES ON THIS PROPERTY. 8.GORDON DOES NOT CERTIFY TO THE LOCATION OF OR THE EXISTENCE OF ANY EXISTING UNDERGROUND UTILITIES. THE EXISTING UNDERGROUND UTILITIES SHOWN HEREON ARE BASED UPON AVAILABLE INFORMATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATION OF ALL UTILITIES BEFORE COMMENCING WORK AND FOR ANY DAMAGES WHICH OCCUR BY HIS FAILURE TO LOCATE OR PRESERVE THESE UNDERGROUND UTILITIES. IF DURING CONSTRUCTION OPERATIONS THE CONTRACTOR SHOULD ENCOUNTER UTILITIES OTHER THAN THOSE SHOWN ON THE PLAN, HE SHALL IMMEDIATELY NOTIFY THE ENGINEER AND TAKE NECESSARY AND PROPER STEPS TO PROTECT THE FACILITY AND INSURE THE CONTINUANCE OF SERVICE. IF NECESSARY, THE SITE PLAN WILL BE MODIFIED TO ELIMINATE THE CONFLICT AT THE DEVELOPER'S EXPENSE. 9.ALL PROPOSED GRADES AS SHOWN HEREIN ARE FINISHED GRADE UNLESS NOTED ON THE PLAN. 10.THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING THE OWNER AND THE ENGINEER OF ANY CHANGES OR CONDITIONS ATTACHED TO PERMITS OBTAINED FROM THE ANY AUTHORITY ISSUING PERMITS. 11.ALL LAND, ON OR OFF SITE, WHICH IS DISTURBED BY THIS DEVELOPMENT, AND WHICH IS NOT BUILT UPON OR SURFACED, SHALL BE ADEQUATELY STABILIZED TO CONTROL EROSION AND SEDIMENTATION. 12.THE CONTRACTOR SHALL PROVIDE ADEQUATE MEANS OF CLEANING TRUCKS AND/OR OTHER EQUIPMENT OF MUD PRIOR TO ENTERING THE RIGHT-OF-WAY, AND IT IS THE CONTRACTORS RESPONSIBILITY TO CLEAN STREETS OF MUD AND/OR ALLAY DUST AND TO TAKE WHATEVER MEASURES NECESSARY TO ENSURE THAT THE STREETS ARE KEPT IN A CLEAN AND DUST FREE CONDITION AT ALL TIMES. 13.DURING CONSTRUCTION, THE CONTRACTOR SHALL PROVIDE BUILDING MANAGER WITH 72 HOURS NOTICE IF SERVICE WILL BE AFFECTED DURING UTILITY INSTALLATION. 14.THE CLIENT, CONTRACTOR, AND/OR SURVEYOR SHALL BE RESPONSIBLE FOR NOTIFYING GORDON OF ANY CONDITIONS FOUND IN THE FIELD THAT VARY FROM WHAT IS SHOWN ON THE PLANS. OBSERVATIONS REGARDING APPARENT INCONSISTENCIES IN THE PLANS SHALL BE BROUGHT TO GORDON'S ATTENTION FOR VERIFICATION PRIOR TO STAKEOUT. 15.ALL HANDICAPPED PARKING SPACES SHALL CONFORM TO THE REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT. (ADA - CURRENT VERSION). ALL TRAILS/SIDEWALKS SHALL COMPLY WITH ADA REQUIREMENTS 16.CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH PERFORMANCE OF ITS WORK AND THE WORK OF ITS SUBCONTRACTORS. GORDON SHALL NOT HAVE CONTROL OVER, CHARGE OF, OR RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. 17.MAINTAIN A MINIMUM VERTICAL CLEARANCE OF ONE (1) FOOT SIX (6) INCHES BETWEEN CROSSINGS OF ALL UTILITY LINES UNLESS OTHERWISE NOTED. 18.APPROVAL OF THIS PLAN SHALL IN NO WAY GRANT PERMISSION BY THE APPROVING JURISDICTION FOR THE CONTRACTOR TO TRESPASS ON OFF-SITE PROPERTIES. 19.WHERE THE ORDINANCES DIFFER BETWEEN LOCAL, STATE, AND FEDERAL REQUIREMENTS, THE MOST RESTRICTIVE SHALL APPLY. 20.NO GEOTECHNICAL REPORT HAS BEEN COMPLETED FOR THIS PROJECT. 21.THE CONTRACTOR SHALL IDENTIFY ALL STAGING AREAS AND LIMITS OF WORK/DISTURBANCE. AREAS OUTSIDE LIMITS OF WORK/DISTURBANCE SHALL NOT BE USED FOR STORAGE OR MOVEMENT OF MATERIALS, MACHINERY OR DEBRIS. 22.THE CONTRACTOR SHALL NOTIFY "MISS UTILITY OF VIRGINIA" DIAL 811 OR 1-800-552-7001, 48 HOURS PRIOR TO THE START OF ANY EXCAVATION OR CONSTRUCTION, FOR THE MARKING OF UNDERGROUND UTILITIES. 23.ALL PRODUCTS AND INSTALLATION SHALL BE IN ACCORDANCE WITH VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT), VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK (VESCH), AND FREDERICK COUNTY ORDINANCES. IF A CONFLICT EXISTS, THE MOST STRINGENT REQUIREMENTS SHALL APPLY. ADA CONSTRUCTION NOTES: 1.ALL ACCESSIBLE ROUTES SHALL COMPLY WITH AMERICANS WITH DISABILITIES ACT (ADA) REQUIREMENTS. 2.ACCESSIBLE ROUTES SHALL BE SLOPED NO MORE THAN 5% LONGITUDINALLY. ACCESIBLE ROUTES WITH SLOPES BETWEEN 5% AND 8.33% SHALL BE CONSTRUCTED AS RAMPS, AND SHALL INCLUDE HANDRAILS, AND LANDINGS SPACED NO MORE THAN 30 FEET APART. 3.THE CONTRACTOR SHALL CONSTRUCT LANDINGS AT A MINIMUM OF 5 FEET IN LENGTH AND SHALL BE AT LEAST AS WIDE AS THE RAMP. 4.THE CROSS SLOPE OF ALL ACCESSIBLE ROUTES, INCLUDING RAMPS AND LANDINGS, SHALL BE NO GREATER THAN 1:48. OUTDOOR LIGHTING: 1.NO ADDITIONAL OUTDOOR LIGHTS ARE PROPOSED WITH THIS PROJECT. FREDERICK WATER CONSTRUCTION NOTES: 1.FREDERICK WATER’S WATER AND SEWER STANDARDS AND SPECIFICATIONS ARE AVAILABLE AT WWW.FREDERICKWATER.COM 2.THE CONTRACTOR SHALL ADHERE TO FREDERICK WATER STANDARDS AND SPECIFICATIONS IN EFFECT AT THE TIME OF CONSTRUCTION. 3.THE CONTRACTOR SHALL SCHEDULE A PRE-CONSTRUCTION MEETING WITH THE FREDERICK WATER INSPECTOR PRIOR TO COMMENCING INSTALLATION OF ANY WATER OR SEWER FACILITIES. CONTRACTOR SHALL ALSO ARRANGE FOR INSPECTION OF SAID FACILITIES BY FREDERICK WATER. OIL WATER SEPARATORS AND/OR GREASE TRAPS MAY BE REQUIRED BY FREDERICK COUNTY BUILDING INSPECTIONS. BOTH FREDERICK COUNTY BUILDING INSPECTIONS AND FREDERICK WATER WILL INSPECT THE INSTALLATION OF THOSE FACILITIES. BOTH INSPECTIONS SHALL BE SCHEDULED BY CONTRACTOR. 4.EXACT LOCATIONS OF WATER AND SEWER SERVICES ON NEW LINES ARE TO BE COORDINATED WITH FREDERICK WATER’S INSPECTOR. a.ADJUST FREDERICK WATER FACILITIES TO GRADE AS REQUIRED BY THE FREDERICK WATER INSPECTOR. ABBREVIATIONS SIGN TREE FIRE HYDRANT STORM DRAINAGE MANHOLE STORM DRAINAGE GRATE INLET STORM DRAINAGE CULVERT POWER POLE ELECTRIC TRANSFORMER LIGHT POLE HANDICAP PARKING MARKING GUY WIRE OVERHEAD WIRE SHRUB MAILBOX CHAIN LINK FENCE BOARD FENCE TREE LINE COMMUNICATION BOX COMMUNICATION HANDHOLE GUARD RAIL ELECTRIC BOX GROUND LIGHT ELECTRIC PANEL ELECTRIC HANDHOLE SANITARY SEWER MANHOLE WATER VALVE ROOF DRAIN DOWNSPOUT HVAC UNIT EXISTING PROPOSED PROPERTY LINE EASEMENT LINE BUILDING FACE RETAINING WALL CURB AND GUTTER WATER MAIN STORM DRAINAGE STRUCTURE STORM DRAINAGE PIPE CONTOURS SPOT ELEVATION CONCRETE HEAVY DUTY ASPHALT PAVEMENT ASPHALT SURFACE COURSE LIMITS OF CONSTRUCTION LIMITS OF WORK REDUCER DUMPSTER PAD SETBACK LINE BOLLARD TRENCH DRAIN 719718718717718 719 720 721 722 723 7 2 4 725 725720720722723724720722723724723724 725 728 729725 724725732730724 725 730 735 735 732 732 734 735736732725730 735 740 740 740 735 741745740735735740740740735740 735 730725 725730735740745739738735730730735 735 740 740 73 5 730727 725 725720729 730 716717717720725724720720720716716718719720720720725725721 72 4 720 720 722 723 724 724725726 724 722 71971971872071571571 9 720718718720 718717715715718719717 714715 716 718 718 717 717 718 718 715715 720720 7 2 1 722 724 723 723 722 724 721 724 722 716 719718720716 716 720 714714715 715 716 717715 714715 713 714 717IPF IPF IPF RBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 TYSON DRIVE - ROUTE 863 80' RIGHT-OF-WAY DB. 733 PG. 517 SA CO MB MBMB MB LP MBMB LP LP LP LP LP LP LP LP LP OHERBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 INV.=713.35' INV.=713.02' INV.=712.84'INV.=713.22' INV.=713.15' INV.=712.11' INV.=711.96' INV.=712.26' INV.=714.07' INV.=715.04'INV.=714.98' INV.=713.45' INV.=712.78' INV.=712.88'24" CMP(3)-48" CMP 15" H D P E 24" HDPE INV.=714.14' C TEL BX TR TR TR TR TR EX. HEADWALL EX. HEADWALL EX. HEADWALL EX. HEADWALL EX. RIP-RAP EX. RIP-RAP EX. RIP-RAP EX. RIP-RAP EX. RIP-RAP EX. CONC. DITCH EX. CONC. DITCH EX. CONC. DITCH EX. HEADWALL EX. CULVERT EX. RIP-RAP EX. RIP-RAP EX. HVAC EX. HVAC TEL BX RD RD RD RD RD RD RD RD RD RD RD TOP=717.34 EX.1 EX.2 EX.3 EX.4 EX.5 EX.6 EX. 7 EX. 8 24" RCP EX.9 EX.10 INV.=716.74' INV.=718.12'12" HDPE12" HDPE12" HDPE 12" HDPE6"PVC 12" HDPE12" HDPE18" HDP E 18" RCP WV ACACAC C E TR E AC E SIGN SIGN SIGN LOT 14 STONEWALL INDUSTRIAL PARK JONES MANAGEMENT ASSOCIATES 4.1667 ACRES MAP #43-19-29 INSTR. #090000242 ZONING - M1 LOT 6 STONEWALL INDUSTRIAL PARK DONALD G. SOWERS4.1667 ACRES 2.5000 ACRES MAP #43-19-58 INSTR. #050008976 ZONING - M1 LOT 4 STONEWALL INDUSTRIAL PARK LAKEVILLE CIRCLE LLC C/O TRANFORM DEVELOPMENT 2.6752 ACRES MAP #43-19-58 INSTR. #050008976 ZONING - M1 LOT 7 STONEWALL INDUSTRIAL PARK PERRY FAMILY PARTNERS IV LLC 3.159 ACRES MAP #43-19-59 INSTR. #130000701 ZONING - M1 LOT 7A STONEWALL INDUSTRIAL PARK RESS PROPERTIES LLC 2.000 ACRES MAP #43-19-59A INSTR. #070003537 ZONING - M1 LOT 8-A STONEWALL INDUSTRIAL PARK LOKEY ENTERPRISES LLC 4.100 ACRES MAP #43-19-62 INSTR. #100008447 ZONING - M1 LOT 35 STONEWALL INDUSTRIAL PARK TMME INVESTMENTS LLC 4.7274 ACRES MAP #43-19-61 INSTR. #050018483 ZONING - M1 LOT 14 STONEWALL INDUSTRIAL PARK JONES MANAGEMENT ASSOCIATES 4.1667 ACRES MAP #43-19-29 INSTR. #090000242 ZONING - M1 LOT 35 STONEWALL INDUSTRIAL PARK TMME INVESTMENTS LLC 4.7274 ACRES MAP #43-19-61 INSTR. #050018483 ZONING - M1 WxWxWxINV.=716.02'N47°34'13"W 990.00'S42°25'47"W 660.00' N42°25'47"E 660.00'S47°34'13"E 990.00'75' FRONT YARD SETBACK 25' REAR YARD SETBACK 25' SIDE YARD SETBACK25' SIDE YARD SETBACKWx Wx Wx Wx WxWxWxWx6" PVC 6" PVC 6" PVC LOADING DOCK EXPANSION FRONT ADA PARKING VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3 EXISTING CONDITIONS03 C-XP-101.DWG C-XP-101 1" = 60' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-XP-101.DWG, 5/23/2023 10:39 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 GRAPHICAL SCALE: 1" = 60' 60 30 0 60 120 180 EXISTING STORM SEWER AS-BUILT SURVEY INFORMATION: 1.THE PROPERTY SHOWN HEREON IS IDENTIFIED AS FREDERICK COUNTY MAP NUMBER 43-19-31 AND IS ZONED M1, UNDER THE FREDERICK COUNTY ZONING ORDINANCE. 2.THIS TOPOGRAPHIC SURVEY WAS COMPLETED UNDER THE DIRECT AND RESPONSIBLE CHARGE OF STANLEY D. HEISER FROM AN ACTUAL AIRBORNE SURVEY AND SUPPLEMENTED WITH A GROUND SURVEY MADE UNDER MY SUPERVISION; THAT THE ORIGINAL AERIAL DATA WAS OBTAINED ON JULY 11, 2022 AND JULY 22, 2022; AND THAT THIS MAP INCLUDING METADATA MEETS MINIMUM ACCURACY STANDARDS UNLESS OTHERWISE NOTED. 3.AERIAL TOPOGRAPHY PREFORMED BY NV5 GEOSPATIAL ON JULY 11, 2022 AND SUPPLEMENTED WITH A GROUND SURVEY BY GORDON ON JULY 22, 2022. 4.COMMITMENT FOR TITLE INSURANCE NOT PROVIDED, THEREFORE ALL UNDERLYING EASEMENTS MAY NOT BE SHOWN HEREON. 5.HORIZONTAL DATUM: NAD 83. 6.VERTICAL DATUM: NAVD 88. VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3 EX. CURB & GUTTER 4 5 WxWxLP L P L P LP RBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 EX. SCUPPER EX. SCUPPER EX. CURB & GUTTER EX. CURB & GUTTER EX CONCRETE EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. RIP-RAP EX. WALK W/STEPS EX. SCUPPER EX. CONC. DUMPSTER PAD EX. HVAC EX. HVAC EX. SCREEN WALL RD RD RD RD RD RD RD RD RD RD RD EX. 6 EX. 7 EX. 8 EX. 9 EX. 10 INV.=716.74' INV.=718.12'12" HDPE12" HDPE12" HDPE 12" HDPE6"PVC 12" HDPE18" RCP EX. CONC. WALKSIGN WxWxINV.=716.02' N42°25'47"E 660.00' EX. 8" WATER LINE EX. 6" WATER LINE EX. 8" WATER LINE NO RECORD OF EXISTING EASEMENT SEE UTILITY PLAN AND PLAT OF EASEMENT FOR ESTABLISHMENT OF NEW EASEMENT 25' REAR YARD SETBACK 6" PVC 6" PVC 6" PVC FFE = 724.95' HEIGHT = +/-28.50' 4 7 7 7 7 7 7 7 7 7 7 1 1 1 2 2 3 4 4 4 5 5 5 5 5 5 5 6 9 9 8 8 9 9 11 5 5 55 13 13 14 15 15 15 15 16 17 5 13 18.04'107.95'8.75' 80.00'18.00'56.90' 3 3 3 3 9 9 12 9 9 18 18 7 10 4. 3 3 ' 19 19 19 19 7 7 11 20 14.46' 8 5 11 11 21 7 7 5 7 37.67' GRAPHICAL SCALE: 1" = 20' 20 10 0 20 40 60 DEMOLITION PLAN04 C-CD-101.DWG C-CD-101 1" = 20' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CD-101.DWG, 5/23/2023 10:30 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 FRONT ADA PARKING DEMOLITION LEGEND DENOTES APPROXIMATE LIMITS OF ASPHALT SURFACE COURSE TO BE REMOVED DENOTES APPROXIMATE LIMITS OF CONCRETE TO BE REMOVED DENOTES APPROXIMATE LIMITS OF LINEAR FEATURES TO BE REMOVED NO DESCRIPTION DEMOLITION KEY REMOVE EXISTING ASPHALT PAVEMENT AND SUBBASE REMOVE EXISTING ASPHALT PAVEMENT SURFACE COURSE WITH A CLEAN EDGE SAWCUT ASPHALT REMOVE EXISTING SIDEWALK REMOVE EXISTING CURB AND GUTTER AND SAWCUT AT NEAREST JOINT REMOVE EXISTING CONCRETE PAVEMENT REMOVE TREE(S) AND/OR SHRUB(S) SALVAGE FIVE (5) HANDICAPPED PARKING SIGNS TO BE REINSTALLED. TWO (2) SIGNS SHALL INDICATE VAN ACCESSIBLE. SIGNS SHOWING LEAST WEAR SHALL BE SALVAGED. DENOTES REMOVAL OF PAVEMENT MATERIALS 1 2 3 4 5 6 7 8 9 10 11 REMOVE PORTION OF EXISTING WATER LINE AND ASSOCIATED STRUCTURES. PROTECT EXISTING VALVE. REMOVE AND SALVAGE EXISTING FIRE HYDRANT REMOVE HVAC (SEE MECHANICAL DRAWINGS) REMOVE PORTION OF EXISTING STORM SEWER REMOVE EXISTING STORM SEWER MANHOLE REMOVE EXISTING GRATE INLET REMOVE EXISTING SIGN TREE REMOVAL 12 13 14 15 16 17 REMOVE HVAC CONCRETE PAD. RESTORE GRADE AND STABILIZE WITH GRASS PROTECT EXISTING LIGHT POLE18 REMOVE EXISTING HEADER CURB DEMOLITION NOTES: 1.THE DEMOLITION PLAN IS A GENERAL GUIDE OF WHAT ITEMS NEED TO BE DEMOLISHED. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO IDENTIFY ALL ITEMS THAT REQUIRE DEMOLITION TO COMPLETE THE PROPOSED CONSTRUCTION. 2.CONTRACTOR SHALL PROTECT ALL EXISTING BUILDINGS AND FEATURES NOT SCHEDULED FOR DEMOLITION FROM DAMAGE DUE TO DEMOLITION PROCEDURES. 3.THIS PLAN INCLUDES EROSION & SEDIMENT CONTROLS THAT ARE REQUIRED TO BE PLACED PRIOR TO ANY DEMOLITION OR DISTURBANCE. FOLLOWING COMPLETION OF DEMOLITION WORK, CONTRACTOR SHALL MODIFY AND ADD EROSION AND SEDIMENT CONTROLS AS SPECIFIED ON THE PLAN ENTITLED 'EROSION AND SEDIMENT CONTROL PLAN PHASE 1' ON SHEET 17, OR AS NECESSARY TO PREVENT SILT AND CONTAMINATED RUNOFF FROM LEAVING THE SITE. 4.ALL MATERIAL FROM DEMOLITION NOT IDENTIFIED FOR REUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF PROPERLY. 5.CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO EXISTING ROADS AND/OR UTILITIES WHICH OCCUR AS A RESULT OF PROJECT CONSTRUCTION WITHIN OR CONTIGUOUS TO THE LIMITS OF CLEARING AND GRADING. 6.REMOVAL OF UTILITIES INCLUDES REMOVAL OF ALL ASSOCIATED APPURTENANCES. 7.PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR IDENTIFYING THE EXACT HORIZONTAL AND VERTICAL LOCATIONS OF THE EXISTING UTILITIES WHERE THE PROPOSED IMPROVEMENTS CROSS OR CONNECT TO IDENTIFY IF CONFLICTS WILL EXIST. THE CONTRACTOR SHALL NOTIFY THE OWNER AND ENGINEER IF CONFLICTS ARE FOUND. 8.PROTECT AND SUPPORT ALL EXISTING UTILITIES TO REMAIN DURING CONSTRUCTION. REMOVE ALL EXISTING SIGNS AND LIGHT POLES ALONG DEMOLISHED ROADWAY AND PARKING AREAS. 9.PROTECT ALL HARDSCAPES TO REMAIN WITHIN WORK ZONE. 10.DEMOLISH ALL RIGID PAVEMENTS (SIDEWALKS, CURB AND GUTTER) TO THE NEAREST JOINT. 11.BOLD ITEMS TO BE REMOVED/SALVAGED AS INDICATED ON THE PLANS. 12.REMOVE AND RELOCATE ALL LIGHT POLE CONDUITS AS NECESSARY TO AVOID PROPOSED IMPROVEMENTS. 13.PROTECT ALL EXISTING LANDSCAPED FEATURES TO REMAIN. SEE EROSION AND SEDIMENT CONTROL PLAN PHASE 1 ON SHEET 17. 14.EXISTING FREDERICK WATER FACILITIES TO BE REMOVED ARE TO BE FURNISHED TO A FREDERICK WATER INSPECTOR. REMOVE EXISTING ROOF LEADER CONNECTION FROM BUILDING TO STORM DRAIN19 REMOVE TREE AND STAMP AT PIPE OUTLET20 PROTECT/MAINTAIN ROOF LEADER FOR FUTURE CONNECTION21 VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3 LP L P L P LP RBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 EX. SCUPPER EX. SCUPPER EX CONCRETE EX. ASPHALT EX. RIP-RAP EX. SCREEN WALL RD RD RD RD EX. 6 EX. 10 INV.=716.74'12" HDPE6"PVC 12" HDPE18" RCP SIGN WxWxINV.=716.02' N42°25'47"E 660.00' EX. 8" WATER LINE 25' REAR YARD SETBACK 6" PVC 6" PVC 6" PVC FFE = 724.95' HEIGHT = +/-28.50' FFE = 724.95' 1 1 1 2 2 12 12 3 3 19 4 4 4 5 6 87 9 9 10 11 13 14 17 18 15 26 15 3 19 20 20 21 21 22 22 22 22 23 25 2726 27 5 5 24 3 11 11 11 28 16 16 4 16 8 16 29 29 EX. CURB & GUTTER 6 77 12 5 GRAPHICAL SCALE: 1" = 20' 20 10 0 20 40 60 SITE PLAN05 C-CS-101.DWG C-CS-101 1" = 20' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CS-101.DWG, 5/23/2023 10:30 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 FRONT ADA PARKING SITE PLAN NOTES: 1.SEE SHEETS 12 THROUGH 15 FOR SITE DETAILS. 2.SEE SHEET 01 FOR LEGENDS AND ABBREVIATIONS. 3.SEE EXISTING CONDITIONS PLAN ON SHEET 03 FOR LOCATIONS OF LOADING DOCK EXPANSION AND FRONT ADA PARKING WITH RESPECT TO THE EXISTING BUILDING. 4.SEE STRUCTURAL DRAWINGS FOR DESIGN OF RETAINING WALLS. 5.FOR ROCK OUTLET PROTECTION DETAIL SEE SHEET 19. 6.SEE SHEET 06 FOR DIMENSIONING AND JOINT LAYOUT. 7.NO NEW MONUMENT SIGNS ARE PROPOSED WITH THIS PROJECT. PAVEMENT LEGEND NO.DESCRIPTION SITE IMPROVEMENTS KEY PR. CONCRETE SIDEWALK1 2 3 4 5 6 7 8 9 10 11 12 DETAIL PR. ASPHALT SURFACE COURSE PR. HEAVY DUTY CONCRETE PR. CURB AND GUTTER; CG-6 PR. CURB AND GUTTER; CG-6R PR. ADA RAMP; CG-12 REINSTALL SALVAGED HANDICAPPED PARKING SIGN PR. LOADING DOCK RETAINING WALLS (SEE STRUCTURAL DRAWINGS) PR. 4,250 SF LOADING DOCK (SEE ARCHITECTURAL DRAWINGS) PR. TRUCK BAYS (SEE ARCHITECTURAL DRAWINGS) RESTRIPE PARKING SPACES A CS-503 F CS-501 E CS-501 B CS-501 B CS-501 D CS-503 13 PR. DUMPSTER PAD 14 PR. CONCRETE DRIVE IN RAMP D CS-501 15 PR. BOLLARDS (TYP.) 16 PR. CURB TRANSITION A CU-201 17 PR. SCUPPER A CS-501 PR. WOODEN SCREENING FENCE18 A CS-504 PR. HEAVY DUTY ASHPALT PAVEMENT19 C CS-501 ROCK OUTLET PROTECTION (SEE E&S DETAILS ON SHEET 19)20 TRANSITION HEAVY DUTY ASPHALT TO HEAVY DUTY CONCRETE21 TRANSITION HEAVY DUTY ASPHALT TO EXISTING ASPHALT RESURFACE22 TRANSITION HEAVY DUTY ASPHALT TO EXISTING ASPHALT PAVEMENT23 TRANSITION HEAVY DUTY ASPHALT TO EXISTING CONCRETE PAVEMENT24 H CS-501 CONCRETE STEPS WITH 6" RISER HEIGHT (SEE GRADING PLAN)25 D CS-504 F CS-501 G CS-501 H CS-501 PR. FIRE LANE SIGN; TYPE A26 PR. FIRE LANE SIGN; TYPE C27 B, C CS-504 B, C CS-504 ASPHALT SURFACE COURSE DUMPSTER PAD CONCRETE (SEE IMPROVEMENTS KEY) HEAVY DUTY ASPHALT PAVEMENT CURB AND GUTTER; CG-6R PR. CURB; CG-2 I CS-501 B CS-501 H GC-501 28 REINSTALL SALVAGED HANDICAPPED VAN PARKING SIGN PR. WHEEL STOP E CS-50429 VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3WWWLP L P L P LP RBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 EX. SCUPPER EX. SCUPPER EX CONCRETE EX. ASPHALT EX. RIP-RAP EX. SCREEN WALL RD RD RD RD EX. 6 EX. 10 INV.=716.74'12" HDPE6"PVC 12" HDPE18" RCP SIGN WxWxINV.=716.02' N42°25'47"E 660.00' EX. 8" WATER LINE 25' REAR YARD SETBACK 6" PVC 6" PVC 6" PVC FFE = 724.95' HEIGHT = +/-28.50' FFE = 724.95' 9 0 . 0 0 9' 9'8'9'42.26'107.95'76'11.5'12'12.5'12' 29.77'67.81'9.25'14.5' 50.15' 50.65'5'6.72'6.72'6.72'6.72'1 2 60' 60' 6' 5'3.78'22.27'R3'32.73'5'16.8'15.81'3'6.7'39.65'6.76'22.5' 5' 61. 6 8 ' 22.82'13.64'3'18'6.72'5'R4 'R15'60' 9 0 . 0 0 24'25'4. 7 9 '12'12'11.42'10'11.41'9.5'13.42'13.43'12.3'14.29' 2 3'6'4.07'5'9' EX. CURB & GUTTER 12.05'5.01'9.5'18'8' 8.28' 5' 6.72' 9.5' 9 0 . 0 0 1 1 GRAPHICAL SCALE: 1" = 20' 20 10 0 20 40 60 DIMENSIONING AND JOINT LAYOUT PLAN06 C-CS-102.DWG C-CS-102 1" = 20' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CS-102.DWG, 5/23/2023 10:30 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 FRONT ADA PARKING DIMENSIONING AND JOINT NOTES: 1.SEE SHEET 13 FOR JOINT AND JOINT SEALANT DETAILS. 2.SEE EXISTING CONDITIONS PLAN ON SHEET 03 FOR LOCATIONS OF LOADING DOCK EXPANSION AND FRONT ADA PARKING WITH RESPECT TO THE EXISTING BUILDING. 3.SEE SITE PLAN ON SHEET 05 FOR PAVEMENT PLAN AND SHEET 12 FOR PAVEMENT CROSS SECTION DETAILS AND TRANSITIONS. PAVEMENT LEGEND CONSTRUCTION JOINT (CJ) NO.DESCRIPTION JOINT KEY CONSTRUCTION JOINT1 2 DETAIL EXPANSION JOINT A, B CS-502 A, B CS-502 EXPANSION JOINT (EJ) VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3 LP LP L P L P RBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 EX. SCUPPER EX. SCUPPER EX CONCRETE EX. ASPHALT EX. RIP-RAP EX. SCREEN WALL RD RD RD RD EX. 6 EX. 10 INV.=716.74'12" HDPE6"PVC 12" HDPE18" RCP SIGN WxWxINV.=716.02' N42°25'47"E 660.00' EX. 8" WATER LINE 25' REAR YARD SETBACK 6" PVC 6" PVC 6" PVC FFE = 724.95' HEIGHT = +/-28.50'WWW725730 735 740 735740740740735740 735 730725 725730735735 725720716720725725721 72 4 720 720 722 723 724 724725 726 724 722 719717720 725730721 722 723 724726727728729731 22.6 23.0 22 80 EP 22 64 FL 23 14 TC 22 60 TC 22 21 TC 22 54 EP 22 33 EP 22 25 EP 21 90 EP 21 82 EP 19.619.6 19.9 23.1 22.8 23.3 24.1 25.0 27.3 26.8 27.1 26.6 26.5 25.9 26.3 24.9 20.0 20.0 20.4 19.9 19 76 FL 20 26 TC 19.8 20 06 EP 19 90 FL2040 TC 21 73 TC 21 25 FL 21 16 EP2125 EP 21 09 FL2159 TC 19 74 EP 23 21 TC 22 71 FL 23 00 EP 23 33 TC 20.2 20.5 23 95 24 83 25 54 26 54 25 88 24 99 EP 25 05 24 54 24 02 23 51 23 14 24 86 24 26 24 56 23 96 24 16 24 95 24 95 25 202426 TC 23 58 TC 23 08 EP 23 36 20 95 EP2192 22 05 21 31 22 83 FL 22 92 1.0% 5.2% 4.0% 4.9%1.7%3.9%1.4%2.0%1.9%1.7%6.3%7 2 4 722723721719 718 22 31 22 45 23 66 22 18 25 35 EP 26 06 26 06 TC 26 06 26 01 TC 26 17 TC 25 58 24 34 24 75 24 93 24 95 24 95 25 39 25 43 26 36 TC 6.2% 7.0% 20 80 20 80 20 80 20 80 20 80 20 95 EP 20 95 20 95 EP 20 95 EP 0.0%19 64 21 10 21 49 20 88 18 72 20 56 19 98 17 48 20 12 19 301725 19 34 25 26 TW 25 45 TW 23 59 TW 25 42 TW 22 78 TC 22 28 FL 22 45 EP 22 49 EP 24 95 24 95 26 53 EP 26 18 EP2672 26 90 EP 26 79 FL 26 98 FL 26 72 EP 27 48 TC2729 TC 24 86 24 55 24 38 24 732486 24 95 24 95 24 85 25 32 TC 24 822473 25 23 TC2536 TC 24 86 22 60 17 00 21 47 20 95 EP 21 82 20 95 EP 24 67 24 67 TOP = 20.96' BOTTOM = 20.46' TOP = 21.53' BOTTOM = 21.03' TOP = 22.10' BOTTOM = 21.60' TOP = 22.67' BOTTOM = 22.17' TOP = 23.23' BOTTOM = 22.73' FFE = 724.95' A A B B 21.6 21.2 21.3 21.4 21.5 21.821.7 22.3 22.4 22 41 TC 22 23 TC 22.2 22.1 21.6 21.4 21 48 21 56 21.6 21 64 EP 21 70 EP 1.2% 1.1%0.5% 0.5%0.7% 1.1%2.0%1.9%1.4%21 77 22 39 TC 22 44 TC 21 82 21 72 TC2167 TC 21 71 21 76 21 71 FL2167 FL 21.821.6 72272221 65 21 69 L P 25 38 EP 25 24 EP 25 12 EP 24 99 FL 25 85 EP 25 47 EP2559 EP 26 36 TC 26 06 TC 26 06 26 01 TC 25 50 TC 26 31 TC26.5 25.9 25 54 25 41 25 30 1.4%1.9%1.0%5.5% 1.4%1.5%1.9%1.4% 1.5%1.9%1.5% 26.6 25 19 FL 25 67 TC 25 51 FL2549 FL2580 FL 25 86 25 55 25 65 TC 26 05 TC 25 65 FL 1.4% 25 452558 25 622575 25 91 EP 25 78 EP 25 71 EP 1.4%1.9%1.5%1.0%25 70 26 20 TC 1.4% 722 22 33 EP 22 67 TC 22 25 EP 21 90 EP 21 82 EP 21 57 FL 21 65 FL2216 TC 22 25 TC 21 44 FL 21 622178 FL 22 57 TC 22 17 FL 21 91 FL721 721 722 18.8%3.3%5.7%2.3%3.9%GRAPHICAL SCALE: 1" = 20' 20 10 0 20 40 60 GRADING AND DRAINAGE PLAN07 C-CG-101.DWG C-CG-101 1" = 20' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CG-101.DWG, 5/23/2023 10:46 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 REAR ADA PARKING GRADING NOTES: 1.CONTRACTOR TO VERIFY EXISTING TOPOGRAPHY AND NOTIFY ENGINEER IMMEDIATELY IF ELEVATIONS ON THE PLAN DO NOT MATCH ELEVATIONS MEASURED IN THE FIELD. 2.CONTRACTOR TO MATCH EXISTING LINE AND GRADE AT CONNECTION TO EXISTING PAVEMENTS. 3.SEE DETAILS 'B' AND 'C' ON SHEET 14 FOR CROSS SECTIONS OF PROPOSED LOADING DOCK EXPANSION. 2.0% XX XX XX XX XX XX XX XX TC FL EP GRADING LEGEND PR. SLOPE DIRECTION OF FLOW ARROW PR. GROUND SPOT SHOT PR. TOP OF CURB ELEVATION PR. FLOW LINE ELEVATION PR. EDGE OF PAVEMENT ELEVATION EX. SPOT SHOT ELEVATION24.2 FRONT ADA PARKINGSCUPPER XX XX TW PR. TOP OF WALL ELEVATION CURB AND GUTTER; CG-6R CURB AND GUTTER; CG-6 TRANSITION GUTTER VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3 LP L P L P LP RBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 EX. SCUPPER EX. SCUPPER EX CONCRETE EX. ASPHALT EX. RIP-RAP EX. SCREEN WALL RD RD RD RD EX. 6 EX. 10 INV.=716.74'12" HDPE6"PVC 12" HDPE18" RCP SIGN WxWxINV.=716.02' N42°25'47"E 660.00' EX. 8" WATER LINE 25' REAR YARD SETBACK 6" PVC 6" PVC 6" PVC FFE = 724.95' HEIGHT = +/-28.50'WWWFFE = 724.95' 1 7 21 2 2 3 5 6 4 8 3 8 11 14 14 14 14 14 9 9 10 16 17 16 18 18 15 15 15 15 15 15 10 19 15 20 20 20 20 13 LOCATE EX. ROOF LEADER AND TIE INTO STRUCTURE 8 AS NECESSARY12 14 17 17 13 13 13 9 14 14 13 CONTRACTOR SHALL CONFIRM EXISTING WATER MAIN IS RESTRAINED PER VALVE RESTRAINT REQUIREMENTS, IF NOT CONTRACTOR SHALL INSTALL RESTRAINTS ON THE EXISTING WATERMAIN SEE PLAT OF EASEMENT FOR CREATION OF 20' FREDERICK WATER EASEMENT GRAPHICAL SCALE: 1" = 20' 20 10 0 20 40 60 UTILITY PLAN08 C-CU-101.DWG C-CU-101 1" = 20' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CU-101.DWG, 5/23/2023 10:31 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 A CU-202 A CU-202 C, D CU-202 B, C CU-202 C CU-202 D CU-501 A, B CU-202 D CU-501 C, F CU-501 UTILITY NOTES: 1.SEE SHEET 09 FOR WATER MAIN PROFILE AND DETAILS. 2.SEE SHEETS 10 AND 11 FOR STORM DRAIN PROFILES, COMPUTATIONS, AND DETAILS. NO.DESCRIPTION UTILITY KEY PR. CONNECTION TO 8" WATER MAIN; EXTEND WATER LINE FROM EXISTING VALVE TO NEW TEE1 2 3 4 5 6 7 8 9 10 11 12 DETAIL 13 14 15 16 PR. 8" CL 52 DIP WATER MAIN PR. 6" CL 52 DIP FIRE HYDRANT LATERAL PR. FIRE HYDRANT PR. 8" TO 6" REDUCER PR. 6" VALVE PR. 8"X8"X6" TEE; 1-8" VALVE; 1-6" VALVE PR. FREDERICK WATER 20' WATER LINE EASEMENT PR. 18" ADS NYLOPAST STRUCTURE; H-20 RATED SOLID TOP PR. ROOF DRAIN CONNECTION PR. 12" HDPE STORM PIPE PR. 18" HDPE STORM PIPE PR. 6" PVC PR. 8" TRENCH DRAIN. SEE TRENCH DRAIN PROFILE SHEET 10 PR. 15" HDPE STORM PIPE PR. 18" ADS NYLOPLAST STRUCTURE; GRATE TOP; CONNECT EXISTING ROOF LEADER 17 18 EX. 12" STORM PIPE TO REMAIN EX. ROOF LEADER TO REMAIN 19 20 PR. 4' VDOT STORM MANHOLE PR. FLARED END SECTION G CU-501 A, B CU-501 INSTALL SALVAGED FIRE HYDRANT21 10+00=8" CONNECTION TO EX. 8" VALVE1-8"X8"X6" TEE;1-8" VALVE; 1-6" VALVE6" FH-1 CONNECTIONINV.=716.5611+39.48=45° HORIZONTAL BENDINV.=718.3412+01.64=1-8" T0 6" REDUCERINV.=719.9012+02.64=1-6" VALVEINV.=719.9212+09.64=FH-2INV.=720.08EX. GRADE 1.5' MIN. CLEAR UNDER STORM MIN4' COVERPR. GRADE 201.64' OF 8" CL 52 DIP 8.00' OF 6" CL 52 DIPMIN4' COVERPUBLIC OWNERSHIP EX. GRADE PR. GRADE 9.82' OF 6" CL 52 DIP4' COVER10+00=10+00 (8" WATERMAIN)1-8"X8"X6" TEE;1-8" VALVE; 1-6" VALVEINV.=716.6510+09.82=FH-1INV.=717.05PUBLIC OWNERSHIPLPLPEX.6EX.106"PVCW10+10 10+00 12+1010+0011+0012+0020' WATER LINE EASEMENT LPLPEX.66"PVCSIGNW10+1010+0010+00 WATER MAIN PROFILE AND UTILITY DETAILS09 C-CU-201.DWG C-CU-201 1" = 50' 1" = 5' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CU-201.DWG, 5/23/2023 10:31 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 FIRE HYDRANTANOT TO SCALE GATE VALVEBNOT TO SCALE RESTRAINED JOINTS FOR VALVES AND REDUCERSCNOT TO SCALE RESTRAINED JOINTS FOR TEES AND BENDSDNOT TO SCALE WATERMAIN CONNECTION TO FH-2 WATERMAIN TO FH-1 WATER NOTES: 1.ALL WATER MATERIALS, APPURTENANCES, AND INSTALLATION SHALL BE IN ACCORDANCE WITH THE LATEST VERSION OF THE "WATER AND SEWER STANDARDS AND SPECIFICATIONS FOR FREDERICK COUNTY". SEE FREDERICK WATER CONSTRUCTION NOTES ON SHEET 02. 2.DUCTILE IRON PIPE SHALL CONFORM TO THE REQUIREMENTS OF AWWA STANDARD C151. THE PIPE SHALL BE CEMENT LINED IN ACCORDANCE WITH AWWA STANDARD C104. UNLESS OTHERWISE SPECIFIED, THE PIPE SHALL HAVE PUSH-ON JOINTS MEETING THE REQUIREMENTS OF AWWA STANDARD C111. THE WALL THICKNESS OF THE PIPE SHALL BE CLASS 52. PIPE SHALL BE MANUFACTURED BY U.S. PIPE, AMERICAN PIPE, OR MCWANE DUCTILE. THE EXTERIOR SHALL BE COATED WITH A LAYER OF ARC-SPRAYED ZINC PER ISO 8179. THE MASS OF THE ZINC APPLIED SHALL BE 200 G/M2 OF PIPE SURFACE AREA. A FINISHING LAYER TOPCOAT SHALL BE APPLIED TO THE ZINC. THE MEAN DRY FILM THICKNESS OF THE FINISHING LAYER SHALL NOT BE LESS THAN 3 MILS WITH A LOCAL MINIMUM NOT LESS THAN 2 MILS. THE ZINC COATING SYSTEM SHALL CONFORM TO ISO 8179-1 “DUCTILE IRON PIPES - EXTERNAL ZINC-BASED COATING - PART 1: METALLIC ZINC WITH FINISHING LAYER. SECOND EDITION 2004-06-01.” VERTICAL SCALE: 1" = 5' 5 2.5 0 5 10 15 HORIZONTAL SCALE: 1" = 50' 50 25 0 50 100 150 STANDARD TRENCHINGENOT TO SCALE 700 705 710 715 720 725 730 735 700 705 710 715 720 725 730 735 10+00 11+00 12+00 13+00 14+0011+46.64=4' MANHOLEINV. OUT=718.21 (18")INV. IN=718.31 (6")INV. IN=718.31 (6")INV. IN=718.31 (15")TOP=721.528A 12+46.64=18" ADS MHINV. OUT=718.81 (15")INV. IN=718.81 (15")INV. IN=718.81 (6")TOP=721.608B 12+21.64=18" ADS MHINV. OUT=718.69 (15")INV. IN=718.69 (15")INV. IN=718.69 (6")TOP=721.278 10+00=FLAIRED END SECTIONINV. IN=717.48 (18")TOP=719.617 12+72.14=18" ADS MHINV. OUT=718.94 (15")INV. IN=719.04 (12")INV. IN=718.94 (6")TOP=721.728C 12+88.18=18" AREA DRAININV. OUT=719.12 (12")INV. IN=719.12 (12")INV. IN=719.12 (6")TOP=724.388D TOP=724.349 13+19.19=18" AREA DRAININV. OUT=719.28 (12"INV. IN=720.36 (EX. 12")INV. IN=720.61 (6")EX. TOP=726.76EX. EX. 10 13+44.16= 15" ADS MHINV. OUT=720.53 (12")INV. IN=720.55 (6")INV. IN=720.55 (12")1.5' MIN. CLEAR OVER WATER LINE PR. GRADE 11+71.64=15"X15"X6" TEECONNNECTION TO TD1INV.=718.3311+96.64=15"X15"X6" TEECONNNECTION TO TD2INV.=718.45EX. GRADE EX. GRADE PR. GRADE 10+69.25=8" W/L XINGINV.=715.46RIP RAP 146.64' - 18" HDPE@ 0.50% EX. 24.97' - 12" HDPE @ 0.68%75.00' - 15" HDPE @0.50%31.01' - 12" HDPE @0.50%16.04' - 12" HDPE @0.50%25.50' - 15" HDPE @0.50%25.00' - 15" HDPE @0.50%HGL LINE HGL LINE BOTTOM OF TRENCH INV. = 719.96' VERTICAL OUTLET ADAPTER TO STRUCTURE TD6 (6" X 6" X 4" T-Y) SEE DETAILS 'E' ADN 'F' ON SHEET 11 13.5'12'12'12'12'12'3'12'12'12'12' 1'1'1'1' FLOW FLOW FLOW FLOW FLOW FLOWFLOWFLOWFLOWFLOWFLOW BOTTOM OF TRENCH INV. = 719.98' VERTICAL OUTLET ADAPTER TO STRUCTURE TD5 (6" X 6" X 4" T-Y) SEE DETAILS 'E' ADN 'F' ON SHEET 11 BOTTOM OF TRENCH INV. = 719.98' VERTICAL OUTLET ADAPTER TO STRUCTURE TD4 (6" X 6" X 4" T-Y) SEE DETAILS 'E' ADN 'F' ON SHEET 11 BOTTOM OF TRENCH INV. = 719.98' VERTICAL OUTLET ADAPTER TO STRUCTURE TD3 (6" X 6" X 4" T-Y) SEE DETAILS 'E' ADN 'F' ON SHEET 11 BOTTOM OF TRENCH INV. = 719.98' VERTICAL OUTLET ADAPTER TO STRUCTURE TD2 (6" X 6" X 4" T-Y) SEE DETAILS 'E' ADN 'F' ON SHEET 11 BOTTOM OF TRENCH INV. = 719.98' VERTICAL OUTLET ADAPTER TO STRUCTURE TD1 (6" X 6" X 4" T-Y) SEE DETAILS 'E' ADN 'F' ON SHEET 11 STORM SEWER PROFILE AND COMPUTATIONS10 C-CU-202.DWG C-CU-202 1" = 50' 1" = 5' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CU-202.DWG, 5/23/2023 10:55 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 VERTICAL SCALE: 1" = 5' 5 2.5 0 5 10 15 HORIZONTAL SCALE: 1" = 50' 50 25 0 50 100 150 STORM DRAIN PROFILE STORM DRAIN COMPUTATIONS STORM DRAIN HGL COMPUTATIONS CITY OF WINCHESTER MANHOLE LIDANOT TO SCALE VDOT MANHOLEBNOT TO SCALE STANDARD DI-3 LID AND FRAME TRENCH DRAIN PROFILE NOT TO SCALE 12.53'6" SANITARY TEE (T-Y) WITH 4" BRANCH; SEE DETAIL 'E' THIS SHEET. ROOF LEADER CONNECTION; SEE UTILITY PLAN CONNECTION TO ADS STRUCTURE OR 15"X15"X6" TEE; SEE UTILITY PLAN ACO FLOW DRAIN ASSEMBLY; SEE DETAIL 'A' AND 'B', THIS SHEET ACO FLOW DRAIN GRATE ASSEMBLY; SEE DETAIL 'C' THIS SHEET ACO FLOW DRAIN VERTICAL OUTLET ADAPTER; SEE DETAIL 'A' THIS SHEET VARIABLE FLOW 6" PVC6" PVC 4" PVC UTILITY DETAILS11 C-CU-501.DWG C-CU-501 SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CU-501.DWG, 5/23/2023 10:31 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 ACO DRAIN TO ROOF LEADER CONNECTIONFNOT TO SCALE ACO TRENCH DRAINANOT TO SCALE ACO TRENCH DRAINBNOT TO SCALE ACO TRENCH DRAIN GRATECNOT TO SCALE ADS 18" NYLOPLAST DRAIN BASINDNOT TO SCALE E NOT TO SCALE 6" X 6" X 4" TEE (T-Y) CONNECTION 18" FLARED END SECTIONGNOT TO SCALE ADS 18" FLARED END SECTION PRODUCT NUMBER: 1810NP INSTALL PER MANUFACTURERS INSTRUCTIONS 1": 1' 2"R4" 6"13"6"2' 6"13"4" 2' 6" 1": 1' 2"R CG-6 CG-6R CG-6R CG-6CG-6 TRANSITION CURB TRANSITION DETAIL (NOT TO SCALE) DETAIL DETAIL NOT TO SCALE NOT TO SCALE DT-CG6R 7" 7" 10'10' 6" 3" IM-19.0A INTERMEDIATE COURSE SM-9.5A SURFACE COURSE TACK COAT 1.5" SUBGRADE COMPACTED TO 95% DENSITY COMPACTED AGGREGATE BASE, TYPE 1 SIZE #21A, 95% DENSITY 8" 6" 4" A3 PORTLAND CEMENT CONCRETE (5000 PSI COMPRESSIVE STRENGTH AT 28 DAYS) #4 BARS @ 12" O.C. (BOTH WAYS) COMPACTED AGGREGATE BASE, TYPE 1 SIZE #21A, 95% DENSITY SUBGRADE COMPACTED TO 95% DENSITY 6" 6" 3" A3 PORTLAND CEMENT CONCRETE (5000 PSI COMPRESSIVE STRENGTH AT 28 DAYS) 4" X 4" - W2.9 X W2.9 WWM REINFORCED STEEL IS NOT CARRIED THROUGH JOINTS SUBGRADE COMPACTED TO 95% DENSITY COMPACTED AGGREGATE BASE, TYPE 1 SIZE #21A, 95% DENSITY CHAIRS AT 2' SPACING O.C. INTERMEDIATE COURSE 1.5" 1V 4H HEAVY DUTY ASPHALT SECTIONEXISTING APSHALT PAVEMENT SECTION 6" 3" 1.5" COMPACTED AGGREGATE BASE, TYPE 1 SIZE #21A, 95% DENSITY SURFACE COURSE MATCH DEPTH OF EXISTING BASE COURSE SURFACE COURSE 1.5" SM-9.5A CONTINUOUS OVER EXISTING PAVEMENT TACK COAT FACE OF EXPOSED INTERMEDIATE COURSE 12"12" EX. INTERMEDIATE COURSE 1V 4H HEAVY DUTY ASPHALT SECTIONEXISTING APSHALT PAVEMENT SECTION 6" 3" 1.5" COMPACTED AGGREGATE BASE, TYPE 1 SIZE #21A, 95% DENSITY SURFACE COURSE MATCH DEPTH OF EXISTING BASE COURSE SURFACE COURSE 1.5" SM-9.5A CONTINUOUS OVER EXISTING PAVEMENT TACK COAT FACE OF EXPOSED INTERMEDIATE COURSE 1.5" EX. HEAVY DUTY ASPHALT SECTION 6" 4.5" BITUMINOUS COURSE(S) 4H (MIN.) TACK COAT 1V 5' MIN HEAVY DUTY CONCRETE SECTION 8" TACK COAT X X X X X X X X X X 3" MAX 6" 4H (MIN.) 1V PER PLAN COMPACTED AGGREGATE BASE, TYPE 1 SIZE #21A, 95% DENSITY X X 5' CURB CUT VDOT SPEC. 414.03, CL. I, TYPE I SCUPPER DETAIL NOT TO SCALE PAVEMENT CG-6 DT-SCUP1 R=2' TYPE A5'2'SITE DETAILS12 C-CS-501.DWG C-CS-501 SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CS-501.DWG, 5/23/2023 10:32 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 CG-6 AND CG-6R CURB B HEAVY DUTY ASPHALT PAVEMENT SECTIONC CONCRETE DUMPSTER PADD E HEAVY DUTY CONCRETE PAVEMENT SECTION NOT TO SCALE NOT TO SCALENOT TO SCALE NOT TO SCALE F TRANSITION LIGHT DUTY FLEXIBLE ASPHALT TO BE RESURFACED TO HEAVY DUTY FLEXIBLE ASPHALT NOT TO SCALE G NOT TO SCALE H NOT TO SCALE TRANSITION EXISTING LIGHT DUTY FLEXIBLE ASPHALT TO HEAVY DUTY FLEXIBLE ASPHALT TRANSITION HEAVY DUTY FLEXIBLE ASPHALT TO HEAVY DUTY CONCRETE PAVEMENT I CG-2 CURB NOT TO SCALE CONCRETE SCUPPERANOT TO SCALE DTW JOINT SEALER INITIAL SAWCUT (1/8") CRACK JOINT BOTTOM BACKER OR INSERT CONTRACTION JOINT W = WIDTH OF SEALANT RESERVOIR (1/2" (MIN), 5/8" (MAX)) D = DEPTH OF SEALANT (1.0 TO 1.5W) T = DEPTH OF INITIAL SAWCUT OR INSERT TYPE JOINT MATERIAL PAVEMENT SURFACE FORMER (CONTRACTION JOINT) SHALL BE 1/4 SLAB THICKNESS NOTE 1: BACKER MATERIAL SHALL MEET THE REQUIREMENTS OF ACI 504R PARAGRAPHS 2.8, 3.4.6.2, 3.4.6.3 AND TABLE AS APPLICABLE. NOTE 2: TOP OF SEALANT WILL BE 1/8" TO 1/4" BELOW TOP OF JOINT SEALANT DETAILS N.T.S. CONSTRUCTION JOINT MATERIALTD BUTTED JOINT BACKER JOINT SEALER PAVEMENT SURFACEW (BACKER MATERIAL) EXPANSION JOINT JOINT SEALER BACKER MATERIALD3/4"PAVEMENT SURFACE JOINT FILLER 3/4" MIN JOINT SEALANT DETAILS (SEPARATING TAPE) CONTRACTION JOINT W TDINITIAL SAWCUT (1/8") OR INSERT CRACK PAVEMENT SURFACE JOINT SEALER JOINT BOTTOM N.T.S. (SEPARATION TAPE) JOINT SEALANT DETAILS BUTTED JOINT JOINT SEALANT DETAILS (SEPARATING TAPE) SEPARATING TAPE JOINT SEALER PAVEMENT SURFACE CONSTRUCTION JOINT W DPAVEMENT SURFACE SEPARATING TAPE JOINT SEALER 3/4" MIN JOINT FILLER EXPANSION JOINT D3/4" NOTE 2: TOP OF SEALANT WILL BE 1/8" TO 1/4" BELOW TOP OF PARAGRAPHS 2.8, 3.4.6.2, 3.4.6.3 AND TABLE AS APPLICABLE. NOTE 1: SEPARATING TAPE SHALL MEET THE REQUIREMENTS OF ACI 504R FORMER (CONTRACTION JOINT) SHALL BE 1/4 SLAB THICKNESS T = DEPTH OF INITIAL SAWCUT OR INSERT TYPE JOINT D = DEPTH OF SEALANT (1.0 TO 1.5W) PAVEMENT SURFACE FOR EXTERIOR PAVEMENTS. W = WIDTH OF SEALANT RESERVOIR (1/2" (MIN), 5/8" (MAX)) SEPARATING TAPE JOINT BOTTOM JOINT BOTTOM PAVEMENT SURFACE FOR EXTERIOR PAVEMENTS. NOTE: EITHER THE SEPARATION TAPE OR BACKER MATERIAL DETAILS SHALL BE USED. THIS DETAIL PER USACE DETAILS RECEIVED 6/5/2020 TE REQUIRED AT ALL FREE EDGE TEJ REQUIRED ADJACENT TO STRUCTURES AND ABUTTING EXISTING CONCRETE SEE JOINT SEAL DETAILS 5' MIN 9" 7" TE REQUIRED AT ALL FREE EDGE TEJ REQUIRED ADJACENT TO STRUCTURES AND ABUTTING EXISTING CONCRETE SEE JOINT SEAL DETAILS 5' MIN 9" 7" THICKENED-EDGE EXPANSION JOINT N.T.S. 7" 5' MIN (TEJ) N.T.S. CONTRACTION/CONSTRUCTION JOINT (CJ) SEE JOINT SEALANT DETAILS 3.5" ± 1/2" 7" 3/4" 3/4" 3" MAX 3" MAX 3" MAX THICKENED-EDGE (TE) JOINT & THICKENED-EDGE EXPANSION JOINT (TEJ) N.T.S. 3/4" OR 1" DIAMETER, 16" LONG DOWEL, SPACED 12" CENTER TO CENTER. ONE END PAINTED AND OILED. NOTES: CONTRACTION JT. (BY SAWING OR INSERT) IS SHOWN. CONSTRUCTION JT. IS SMOOTH JT. (BUTT JOINT) CREATED BY FORMING. BOTH JOINT TYPES SHALL BE DOWELED. NON-EXTRUDING JOINT FILLER STRIP 2.75" 4" x 4" - W4 xW4 WWM 2.75" 4" x 4" - W4 xW4 WWM NON-EXTRUDING JOINT FILLER STRIP 2.75" 4" x 4" - W4 xW4 WWM x x x x x x x x x SITE DETAILS13 C-CS-501.DWG C-CS-501 SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CS-501.DWG, 5/23/2023 10:32 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 A JOINT SEALANT DETAILS NOT TO SCALE B JOINT DETAILS NOT TO SCALE BUILDING FACE TRENCH DRAIN RIM = 720.80'720.95' F.F.E.= 724.95' EDGE OF DRIVE AISLE 723.28'723.24' 6'54.00'5' 4.59% BUILDING FACE TRENCH DRAIN RIM = 720.80'720.95' F.F.E.= 724.95' EDGE OF DRIVE AISLE 724.73'724.68' 6'54.00'5' 7.35%SITE DETAILS14 C-CS-501.DWG C-CS-501 SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CS-501.DWG, 5/23/2023 10:32 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 CG-12 DETECTABLE WARNING SURFACE (PARALLEL INSTALLATION)D STANDARD CONCRETE SIDEWALKANOT TO SCALE NOT TO SCALE LOADING DOCK CROSS SECTION A-ABNOT TO SCALE LOADING DOCK CROSS SECTION B-BCNOT TO SCALE NOTES: CAP BOARDALUMINUM POST CAP 3. ALL LUMBER SHALL BE PRESSURE TREATED SOUTHERN 1. PROVIDE SHOP DRAWINGS FOR REVIEW BY THE OWNERS REPRESENTATIVE PRIOR TO FABRICATION OR INSTALLATION. 1.25 " MAX 1X4 OR 1X6 SLATS, 2 FINISH NAILS AT EACH BEAM TOP VIEW, CAP BOARD REMOVED BEAM SLAT POST, SEE TABLEPOST 3,000 PSI CONCRETE 2. INSTALLATION AND ALIGNMENT OF THE FENCE TO BE IN ACCORDANCE WITH THE CONTRACT DRAWINGS.6'0"114"MIN.14"3" MAX. 8'-0" YELLOW PINE (0.04 CCA). 2X4 BEAMS, SEE TABLE, GALVANIZED SUPPORT BRACKET REQUIRED 14"INCLUDE GATES, CONNECTION DETAILS, AND ANY OTHER NON-STANDARD DETAILS. NOTES: G. OTHER SPECIAL SIGNS AS APPROVED BY THE OFFICE OF THE FIRE MARSHAL. BETWEEN SIGNS IS 70 FEET. SPACED AS ON APPROVED PLANS. IN LONG STRETCHES THE MAXIMUM DISTANCE INSTALLATION FROM THE OFFICE OF THE FIRE MARSHAL. SIGNS SHOULD BE UNLESS WRITTEN PERMISSION FOR ALTERNATIVES IS OBTAINED PRIOR TO SOLID HEAD 1 1/2" WIDE AND 2" DEEP. AREAS WHERE NO CURB EXISTS. PAINT SHALL BE TRAFFIC YELLOW GRADE. A 6" YELLOW STRIPE SHALL BE PAINTED ON PAVEMENT EDGE IN FIRE LANE F. POSTS FOR SIGNS, WHEN REQUIRED, SHALL BE METAL AND SECURELY MOUNTED. E. SIGNS ARE TO BE MOUNTED 7' FROM THE GROUND TO THE BOTTOM OF THE SIGN UNLESS OTHERWISE DIRECTED BY THE OFFICE OF THE FIRE MARSHAL. APPROVED SIGNS SHALL BE AS FOLLOWS: A. METAL CONSTRUCTION, 12" x 18". AROUND ENTIRE OUTER EDGE OF SIGN. B. RED LETTERS ON REFLECTIVE WHITE BACKGROUND WITH 3/8" RED TRIM STRIP C. LETTERING TO BE AS SHOWN ABOVE. "OR" - 1", "FIRE LANE" - 2 1/2", ARROWS 1" X 6" SOLID SHAFT WITH A D. LETTERING SIZE TO BE AS FOLLOWS: "NO PARKING" OR "STANDING" - 2", ALL CURBS OR PAVED SPACES DESIGNATED AS FIRE LANES SHALL BE INDICATED BY YELLOW PAINT AS APPROVED BY THE FIRE PREVENTION DIVISION. DT-FIRES FIRE LANE NO TYPE A PARKING TYPE D LANE FIRE PARKING LANE FIRE PARKING NO TYPE C NO 36"7'3"-4" TAPER 1-1/4" 3-1/8"1.516NUT AND WASHER SECTION SIGN MOUNTS BETWEEN FRONT WASHER AND SIGN POST REQUIRED HARDWARE: 2-5/16" X 2-1/2" HEX-HEAD BOLTS 2-5/16" HEX NUTS 4-5/16" FLAT WASHERS (ZINC PLATED) 5/16" HEX NUT 5/16" FLAT WASHER 5/16" FLAT WASHER GROUND LEVEL FRONT WASHER BOLT AND WASHER 5/16" X 2-1/2" HEX-HEAD BOLT STANDARD 2#/10' GALVANIZED STEEL U-CHANNEL SIGN POST COLOR AS EXISTING 3/8" HOLES SPACED 1" ON CENTER 2#/10' GALVANIZED STEEL U-CHANNEL SIGN POST C PARKING STALLL R=5"18"5"TYP1'-0"9° 4'-6"9'-0"EDGE OF PVMT26"4" R=1 8 " R=13"6" 4"10" 12"6"6"6" 6" 1" PAINT BLUE PAINT WHITE 20" 4" WIDE BLUE STRIPING4'-0" TOPAINT WHITE SAMPLE TO ENGINEER FOR APPROVAL CONTRACTOR TO SUBMIT PRODUCT (3'-0" MIN. LENGTH) #4 REBAR (TYP.) A1 6'-0" A1 PRE-CAST WHEEL STOP PRIOR TO INSTALLATION. SECTION A1-A1 CONC. MIN. 6" 9" 3000 PSI SITE DETAILS15 C-CS-501.DWG C-CS-501 SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-CS-501.DWG, 5/23/2023 10:32 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 WOODEN SCREENING FENCEASCALE: 3/8" = 1'-0" NO PARKING SIGNSBNOT TO SCALE SIGN POSTCNOT TO SCALE ADA PARKING STRIPINGDNOT TO SCALE CONCRETE WHEEL STOPENOT TO SCALE EROSION AND SEDIMENT CONTROL NOTES16 C-GC-001.DWG C-GC-001 SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-GC-001.DWG, 5/23/2023 10:32 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 E&S CONTROL MINIMUM STANDARDS: A VESCP MUST BE CONSISTENT WITH THE FOLLOWING CRITERIA, TECHNIQUES AND METHODS: 1.PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN SEVEN DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN DORMANT FOR LONGER THAN 14 DAYS. PERMANENT STABILIZATION SHALL BE APPLIED TO AREAS THAT ARE TO BE LEFT DORMANT FOR MORE THAN ONE YEAR. 2.DURING CONSTRUCTION OF THE PROJECT, SOIL STOCK PILES AND BORROW AREAS SHALL BE STABILIZED OR PROTECTED WITH SEDIMENT TRAPPING MEASURES. THE APPLICANT IS RESPONSIBLE FOR THE TEMPORARY PROTECTION AND PERMANENT STABILIZATION OF ALL SOIL STOCKPILES ON SITE AS WELL AS BORROW AREAS AND SOIL INTENTIONALLY TRANSPORTED FROM THE PROJECT SITE. 3.A PERMANENT VEGETATIVE COVER SHALL BE ESTABLISHED ON DENUDED AREAS NOT OTHERWISE PERMANENTLY STABILIZED. PERMANENT VEGETATION SHALL NOT BE CONSIDERED ESTABLISHED UNTIL A GROUND COVER IS ACHIEVED THAT IS UNIFORM, MATURE ENOUGH TO SURVIVE AND WILL INHIBIT EROSION. 4.SEDIMENT BASINS AND TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS AND OTHER MEASURES INTENDED TO TRAP SEDIMENT SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND-DISTURBING ACTIVITY AND SHALL BE MADE FUNCTIONAL BEFORE UPSLOPE LAND DISTURBANCE TAKES PLACE. 5.STABILIZATION MEASURES SHALL BE APPLIED TO EARTHEN STRUCTURES SUCH AS DAMS, DIKES AND DIVERSIONS IMMEDIATELY AFTER INSTALLATION. 6.SEDIMENT TRAPS AND SEDIMENT BASINS SHALL BE DESIGNED AND CONSTRUCTED BASED UPON THE TOTAL DRAINAGE AREA TO BE SERVED BY THE TRAP OR BASIN. A.THE MINIMUM STORAGE CAPACITY OF A SEDIMENT TRAP SHALL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA AND THE TRAP SHALL ONLY CONTROL DRAINAGE AREAS LESS THAN THREE ACRES. B.SURFACE RUNOFF FROM DISTURBED AREAS THAT IS COMPRISED OF FLOW FROM DRAINAGE AREAS GREATER THAN OR EQUAL TO THREE ACRES SHALL BE CONTROLLED BY A SEDIMENT BASIN. THE MINIMUM STORAGE CAPACITY OF A SEDIMENT BASIN SHALL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA. THE OUTFALL SYSTEM SHALL, AT A MINIMUM, MAINTAIN THE STRUCTURAL INTEGRITY OF THE BASIN DURING A 25-YEAR STORM OF 24-HOUR DURATION. RUNOFF COEFFICIENTS USED IN RUNOFF CALCULATIONS SHALL CORRESPOND TO A BARE EARTH CONDITION OR THOSE CONDITIONS EXPECTED TO EXIST WHILE THE SEDIMENT BASIN IS UTILIZED. 7.CUT AND FILL SLOPES SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT WILL MINIMIZE EROSION. SLOPES THAT ARE FOUND TO BE ERODING EXCESSIVELY WITHIN ONE YEAR OF PERMANENT STABILIZATION SHALL BE PROVIDED WITH ADDITIONAL SLOPE STABILIZING MEASURES UNTIL THE PROBLEM IS CORRECTED. 8.CONCENTRATED RUNOFF SHALL NOT FLOW DOWN CUT OR FILL SLOPES UNLESS CONTAINED WITHIN AN ADEQUATE TEMPORARY OR PERMANENT CHANNEL, FLUME OR SLOPE DRAIN STRUCTURE. 9.WHENEVER WATER SEEPS FROM A SLOPE FACE, ADEQUATE DRAINAGE OR OTHER PROTECTION SHALL BE PROVIDED. 10.ALL STORM SEWER INLETS THAT ARE MADE OPERABLE DURING CONSTRUCTION SHALL BE PROTECTED SO THAT SEDIMENT-LADEN WATER CANNOT ENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEING FILTERED OR OTHERWISE TREATED TO REMOVE SEDIMENT. 11.BEFORE NEWLY CONSTRUCTED STORMWATER CONVEYANCE CHANNELS OR PIPES ARE MADE OPERATIONAL, ADEQUATE OUTLET PROTECTION AND ANY REQUIRED TEMPORARY OR PERMANENT CHANNEL LINING SHALL BE INSTALLED IN BOTH THE CONVEYANCE CHANNEL AND RECEIVING CHANNEL. 12.WHEN WORK IN A LIVE WATERCOURSE IS PERFORMED, PRECAUTIONS SHALL BE TAKEN TO MINIMIZE ENCROACHMENT, CONTROL SEDIMENT TRANSPORT AND STABILIZE THE WORK AREA TO THE GREATEST EXTENT POSSIBLE DURING CONSTRUCTION. NONERODIBLE MATERIAL SHALL BE USED FOR THE CONSTRUCTION OF CAUSEWAYS AND COFFERDAMS. EARTHEN FILL MAY BE USED FOR THESE STRUCTURES IF ARMORED BY NONERODIBLE COVER MATERIALS. 13.WHEN A LIVE WATERCOURSE MUST BE CROSSED BY CONSTRUCTION VEHICLES MORE THAN TWICE IN ANY SIX-MONTH PERIOD, A TEMPORARY VEHICULAR STREAM CROSSING CONSTRUCTED OF NONERODIBLE MATERIAL SHALL BE PROVIDED. 14.ALL APPLICABLE FEDERAL, STATE AND LOCAL REQUIREMENTS PERTAINING TO WORKING IN OR CROSSING LIVE WATERCOURSES SHALL BE MET. 15.THE BED AND BANKS OF A WATERCOURSE SHALL BE STABILIZED IMMEDIATELY AFTER WORK IN THE WATERCOURSE IS COMPLETED. 16.UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TO OTHER APPLICABLE CRITERIA: A.NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME. B.EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES. C.EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVED SEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER THAT DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFF-SITE PROPERTY. D.MATERIAL USED FOR BACKFILLING TRENCHES SHALL BE PROPERLY COMPACTED IN ORDER TO MINIMIZE EROSION AND PROMOTE STABILIZATION. E.RESTABILIZATION SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THIS CHAPTER. F. APPLICABLE SAFETY REQUIREMENTS SHALL BE COMPLIED WITH. 17.WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED OR PUBLIC ROADS, PROVISIONS SHALL BE MADE TO MINIMIZE THE TRANSPORT OF SEDIMENT BY VEHICULAR TRACKING ONTO THE PAVED SURFACE. WHERE SEDIMENT IS TRANSPORTED ONTO A PAVED OR PUBLIC ROAD SURFACE, THE ROAD SURFACE SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM THE ROADS BY SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. THIS PROVISION SHALL APPLY TO INDIVIDUAL DEVELOPMENT LOTS AS WELL AS TO LARGER LAND-DISTURBING ACTIVITIES. 18.ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, UNLESS OTHERWISE AUTHORIZED BY THE VESCP AUTHORITY. TRAPPED SEDIMENT AND THE DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES SHALL BE PERMANENTLY STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION. 19.PROPERTIES AND WATERWAYS DOWNSTREAM FROM DEVELOPMENT SITES SHALL BE PROTECTED FROM SEDIMENT DEPOSITION, EROSION AND DAMAGE DUE TO INCREASES IN VOLUME, VELOCITY AND PEAK FLOW RATE OF STORMWATER RUNOFF FOR THE STATED FREQUENCY STORM OF 24-HOUR DURATION IN ACCORDANCE WITH THE FOLLOWING STANDARDS AND CRITERIA. STREAM RESTORATION AND RELOCATION PROJECTS THAT INCORPORATE NATURAL CHANNEL DESIGN CONCEPTS ARE NOT MAN-MADE CHANNELS AND SHALL BE EXEMPT FROM ANY FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MAN-MADE CHANNELS: A.CONCENTRATED STORMWATER RUNOFF LEAVING A DEVELOPMENT SITE SHALL BE DISCHARGED DIRECTLY INTO AN ADEQUATE NATURAL OR MAN-MADE RECEIVING CHANNEL, PIPE OR STORM SEWER SYSTEM. FOR THOSE SITES WHERE RUNOFF IS DISCHARGED INTO A PIPE OR PIPE SYSTEM, DOWNSTREAM STABILITY ANALYSES AT THE OUTFALL OF THE PIPE OR PIPE SYSTEM SHALL BE PERFORMED. B.ADEQUACY OF ALL CHANNELS AND PIPES SHALL BE VERIFIED IN THE FOLLOWING MANNER: (1)THE APPLICANT SHALL DEMONSTRATE THAT THE TOTAL DRAINAGE AREA TO THE POINT OF ANALYSIS WITHIN THE CHANNEL IS 100 TIMES GREATER THAN THE CONTRIBUTING DRAINAGE AREA OF THE PROJECT IN QUESTION; OR (2)(A) NATURAL CHANNELS SHALL BE ANALYZED BY THE USE OF A TWO-YEAR STORM TO VERIFY THAT STORMWATER WILL NOT OVERTOP CHANNEL BANKS NOR CAUSE EROSION OF CHANNEL BED OR BANKS; (B)ALL PREVIOUSLY CONSTRUCTED MAN-MADE CHANNELS SHALL BE ANALYZED BY THE USE OF A 10-YEAR STORM TO VERIFY THAT STORMWATER WILL NOT OVERTOP ITS BANKS AND BY THE USE OF A TWO-YEAR STORM TO DEMONSTRATE THAT STORMWATER WILL NOT CAUSE EROSION OF CHANNEL BED OR BANKS; AND (C)PIPES AND STORM SEWER SYSTEMS SHALL BE ANALYZED BY THE USE OF A 10-YEAR STORM TO VERIFY THAT STORMWATER WILL BE CONTAINED WITHIN THE PIPE OR SYSTEM. C.IF EXISTING NATURAL RECEIVING CHANNELS OR PREVIOUSLY CONSTRUCTED MAN-MADE CHANNELS OR PIPES ARE NOT ADEQUATE, THE APPLICANT SHALL: E&S CONTROL MINIMUM STANDARDS (CONT.): (1)IMPROVE THE CHANNELS TO A CONDITION WHERE A 10-YEAR STORM WILL NOT OVERTOP THE BANKS AND A TWO-YEAR STORM WILL NOT CAUSE EROSION TO THE CHANNEL, THE BED, OR THE BANKS; (2)IMPROVE THE PIPE OR PIPE SYSTEM TO A CONDITION WHERE THE 10-YEAR STORM IS CONTAINED WITHIN THE APPURTENANCES; (3)DEVELOP A SITE DESIGN THAT WILL NOT CAUSE THE PRE-DEVELOPMENT PEAK RUNOFF RATE FROM A TWO-YEAR STORM TO INCREASE WHEN RUNOFF OUTFALLS INTO A NATURAL CHANNEL OR WILL NOT CAUSE THE PRE-DEVELOPMENT PEAK RUNOFF RATE FROM A 10-YEAR STORM TO INCREASE WHEN RUNOFF OUTFALLS INTO A MAN-MADE CHANNEL; OR (4)PROVIDE A COMBINATION OF CHANNEL IMPROVEMENT, STORMWATER DETENTION OR OTHER MEASURES WHICH IS SATISFACTORY TO THE VESCP AUTHORITY TO PREVENT DOWNSTREAM EROSION. D.THE APPLICANT SHALL PROVIDE EVIDENCE OF PERMISSION TO MAKE THE IMPROVEMENTS. E.ALL HYDROLOGIC ANALYSES SHALL BE BASED ON THE EXISTING WATERSHED CHARACTERISTICS AND THE ULTIMATE DEVELOPMENT CONDITION OF THE SUBJECT PROJECT. F. IF THE APPLICANT CHOOSES AN OPTION THAT INCLUDES STORMWATER DETENTION, HE SHALL OBTAIN APPROVAL FROM THE VESCP OF A PLAN FOR MAINTENANCE OF THE DETENTION FACILITIES. THE PLAN SHALL SET FORTH THE MAINTENANCE REQUIREMENTS OF THE FACILITY AND THE PERSON RESPONSIBLE FOR PERFORMING THE MAINTENANCE. G.OUTFALL FROM A DETENTION FACILITY SHALL BE DISCHARGED TO A RECEIVING CHANNEL, AND ENERGY DISSIPATORS SHALL BE PLACED AT THE OUTFALL OF ALL DETENTION FACILITIES AS NECESSARY TO PROVIDE A STABILIZED TRANSITION FROM THE FACILITY TO THE RECEIVING CHANNEL. H.ALL ON-SITE CHANNELS MUST BE VERIFIED TO BE ADEQUATE. I. INCREASED VOLUMES OF SHEET FLOWS THAT MAY CAUSE EROSION OR SEDIMENTATION ON ADJACENT PROPERTY SHALL BE DIVERTED TO A STABLE OUTLET, ADEQUATE CHANNEL, PIPE OR PIPE SYSTEM, OR TO A DETENTION FACILITY. J. IN APPLYING THESE STORMWATER MANAGEMENT CRITERIA, INDIVIDUAL LOTS OR PARCELS IN A RESIDENTIAL, COMMERCIAL OR INDUSTRIAL DEVELOPMENT SHALL NOT BE CONSIDERED TO BE SEPARATE DEVELOPMENT PROJECTS. INSTEAD, THE DEVELOPMENT, AS A WHOLE, SHALL BE CONSIDERED TO BE A SINGLE DEVELOPMENT PROJECT. HYDROLOGIC PARAMETERS THAT REFLECT THE ULTIMATE DEVELOPMENT CONDITION SHALL BE USED IN ALL ENGINEERING CALCULATIONS. K.ALL MEASURES USED TO PROTECT PROPERTIES AND WATERWAYS SHALL BE EMPLOYED IN A MANNER WHICH MINIMIZES IMPACTS ON THE PHYSICAL, CHEMICAL AND BIOLOGICAL INTEGRITY OF RIVERS, STREAMS AND OTHER WATERS OF THE STATE. L. ANY PLAN APPROVED PRIOR TO JULY 1, 2014, THAT PROVIDES FOR STORMWATER MANAGEMENT THAT ADDRESSES ANY FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MAN-MADE CHANNELS SHALL SATISFY THE FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MAN-MADE CHANNELS IF THE PRACTICES ARE DESIGNED TO (I) DETAIN THE WATER QUALITY VOLUME AND TO RELEASE IT OVER 48 HOURS; (II) DETAIN AND RELEASE OVER A 24-HOUR PERIOD THE EXPECTED RAINFALL RESULTING FROM THE ONE YEAR, 24-HOUR STORM; AND (III) REDUCE THE ALLOWABLE PEAK FLOW RATE RESULTING FROM THE 1.5, 2, AND 10-YEAR, 24-HOUR STORMS TO A LEVEL THAT IS LESS THAN OR EQUAL TO THE PEAK FLOW RATE FROM THE SITE ASSUMING IT WAS IN A GOOD FORESTED CONDITION, ACHIEVED THROUGH MULTIPLICATION OF THE FORESTED PEAK FLOW RATE BY A REDUCTION FACTOR THAT IS EQUAL TO THE RUNOFF VOLUME FROM THE SITE WHEN IT WAS IN A GOOD FORESTED CONDITION DIVIDED BY THE RUNOFF VOLUME FROM THE SITE IN ITS PROPOSED CONDITION, AND SHALL BE EXEMPT FROM ANY FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MAN-MADE CHANNELS AS DEFINED IN ANY REGULATIONS PROMULGATED PURSUANT TO § 62.1-44.15:54 OR 62.1-44.15:65 OF THE ACT. M.FOR PLANS APPROVED ON AND AFTER JULY 1, 2014, THE FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS OF § 62.1-44.15:52 A OF THE ACT AND THIS SUBSECTION SHALL BE SATISFIED BY COMPLIANCE WITH WATER QUANTITY REQUIREMENTS IN THE STORMWATER MANAGEMENT ACT (§ 62.1-44.15:24 ET SEQ. OF THE CODE OF VIRGINIA) AND ATTENDANT REGULATIONS, UNLESS SUCH LAND-DISTURBING ACTIVITIES (I) ARE IN ACCORDANCE WITH PROVISIONS FOR TIME LIMITS ON APPLICABILITY OF APPROVED DESIGN CRITERIA IN 9VAC25-870-47 OR GRANDFATHERING IN 9VAC25-870-48 OF THE VIRGINIA STORMWATER MANAGEMENT PROGRAM (VSMP) REGULATION, IN WHICH CASE THE FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS OF § 62.1-44.15:52 A OF THE ACT SHALL APPLY, OR (II) ARE EXEMPT PURSUANT TO § 62.1-44.15:34 C 7 OF THE ACT. N.COMPLIANCE WITH THE WATER QUANTITY MINIMUM STANDARDS SET OUT IN 9VAC25-870-66 OF THE VIRGINIA STORMWATER MANAGEMENT PROGRAM (VSMP) REGULATION SHALL BE DEEMED TO SATISFY THE REQUIREMENTS OF THIS SUBDIVISION 19. EROSION AND SEDIMENT CONTROL NARRATIVE THE SITE DISTURBANCE IS GREATER THAN 10,000 SF. THEREFORE, PER SECTION 143-110, VIRGINIA EROSION AND SEDIMENT CONTROL PROGRAM (VESCP) LAND DISTURBANCE OR VESCP LAND-DISTURBING ACTIVITY, THE SITE DISTURBANCE IS CLASSIFIED AS AN EROSION AND SEDIMENT CONTROL LAND DISTURBING ACTIVITY AND IS SUBJECT TO THE REQUIREMENTS OF SECTION 143-160 OF THE FREDERICK COUNTY CODE. SEE OUTFALL ANALYSIS ON SHEET 20. PROJECT DESCRIPTION: THE PURPOSE OF THIS PROJECT IS THE CONSTRUCTION OF A LOADING DOCK EXPANSION ALONG THE SOUTH WESTERN PORTION OF THE EXISTING BUILDING, INCLUDING A DRIVE-IN RAMP, AND THE RELOCATION OF STORM SEWER INFRASTRUCTURE AND FIRE HYDRANTS. THE TOTAL DISTURBED AREA IS APPROXIMATELY 0.58 ACRES OR 25,386 SF. EXISTING SITE CONDITIONS: THE EXISTING SITE CONSISTS OF WAREHOUSING SPACE AND A VALLEY HEALTH EPIC TRAINING CENTER. SEE APPROVED SITE PLAN SP# 26-13. MULTIPLE EXISTING LOADING DOCKS ARE LOCATED ALONG THE SOUTH WESTERN PORTION OF THE BUILDING. A MAJORITY OF THE SITE IS VERY FLAT WITH SLOPES RANGING FROM LESS THAN 1% TO 5% AND DRAINS TO THE SOUTH EAST TO EXISTING CULVERTS ADJACENT TO TYSON DRIVE. THE WESTERN CORNER OF THE SITE NEAR WHERE IMPROVEMENTS ARE PROPOSED CONTAINS SLOPES RANGING FROM 5% TO 27%. ADJACENT AREAS: THE SITE IS SURROUNDED BY SIMILAR WAREHOUSING AND DISTRIBUTION FACILITIES ALL ZONED M1. THE ONLY ROAD ADJACENT TO THE SITE IS TYSON DRIVE ALONG THE SOUTH EASTERN PROPERTY LINE. OFF-SITE AREAS: THERE ARE NO PLANNED OFF-SITE AREAS FOR THIS PROJECT. ALL WORK SHALL BE COMPLETED INSIDE OF THE PROPERTY. SOILS: SOIL DATA HAS BEEN OBTAINED FROM WEB SOIL SURVEY. THE SOILS ON THE SITE ARE: -(5C) CARBO SILT LOAM, 7 TO 15 PERCENT SLOPES, WELL DRAINED, K=0.43, VERY LOW TO MODERATELY LOW CAPACITY 0.00 TO 0.06 IN/HR., HYDROLOGIC SOIL GROUP 'D' -(32B) OAKLET SILT LOAM, 2 TO 7 PERCENT SLOPES, WELL DRAINED, K=0.37, MODERATELY LOW TO MODERATELY HIGH CAPACITY 0.06 TO 0.20 IN/HR., HYDROLOGIC SOIL GROUP 'C' -(14B) FREDERICK-POPLIMENTO LAOMS, 2 TO 7 PERCENT SLOPES, WELL DRAINED, K=0.28, MODERATELY HIGH TO HIGH CAPACITY 0.57 TO 1.98 IN/HR,. HYDROLOGIC SOIL GROUP 'B' -(39B) SWIMLEY SILT LOAM, 2 TO 7 PERCENT SLOPES, WELL DRAINED, K=0.43, MODERATELY HIGH TO HIGH CAPACITY 0.57 TO 1.98 IN/HR,. HYDROLOGIC SOIL GROUP 'B' SEE MAP BELOW FOR SOIL BOUNDARIES: GENERAL EROSION AND SEDIMENT CONTROL NOTES: 1.DEVICES SHOWN ON PLANS ARE TO BE CONSIDERED THE MINIMUM EROSION AND SEDIMENT CONTROLS. PROVIDE ADDITIONAL DEVICES AS NEEDED IN ORDER TO CONTROL EROSION AND SEDIMENTATION. 2.EROSION AND SEDIMENT CONTROL MEASURES SHALL BE INSTALLED AND MAINTAINED ACCORDING TO THE STANDARDS AND SPECIFICATIONS IN THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK. 3.ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED. 4.PROVIDE CLEANING AND REMOVAL OF SEDIMENT AND MUD FROM PUBLIC OR PRIVATE ROADWAYS AS NECESSARY. 5.TOPSOIL THAT HAS BEEN STOCKPILED IS TO BE SURROUNDED BY SILT FENCE OR OTHER MEASURES AND SHALL BE PROTECTED BY MULCH AND/OR TEMPORARY VEGETATION AT ALL TIMES IMMEDIATELY AFTER GRADING. ADDITIONAL MEASURES TO INCLUDE BE NOT LIMITED TO; BERMS, DIKES, SILT FENCE SANDBAGS OR STRAW BALE BARRIERS. 6.ALL EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO OR AS THE FIRST STEP IN CLEARING. 7.THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANY ADDITIONAL EROSION CONTROL MEASURES AS NECESSARY TO PREVENT EROSION AND SEDIMENTATION. 8.TRAPPED SEDIMENT IS TO BE REMOVED AS REQUIRED TO MAINTAIN EFFICIENCY AND TO BE DISPOSED OF BY SPREADING ON-SITE. 9.TRENCHING ACTIVITIES SHALL BE DONE IN ACCORDANCE WITH THE VIRGINIA EROSION AND SEDIMENT CONTROL MINIMUM STANDARDS SECTION 16 AND IN ACCORDANCE WITH FREDERICK WATER TRENCHING AND BEDDING DETAIL ON SHEET CU-202. MAINTENANCE: THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES DAILY AND AFTER EACH RUNOFF-PRODUCING RAINFALL EVENT. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS OF THE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. THE FOLLOWING ITEMS SHALL BE CHECKED IN PARTICULAR: 1.CONSTRUCTION ENTRANCE (3.02): SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOW OF MUD ONTO PUBLIC RIGHT-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL STONE OR THE WASHING AND REWORKING OF EXISTING STONE AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF ANY STRUCTURES USED TO TRAP SEDIMENT. ALL MATERIALS SPILLED, DROPPED, WASHED, OR TRACKED FROM VEHICLES ONTO ROADWAYS OR INTO STORM DRAINS MUST BE REMOVED IMMEDIATELY. 2.SILT FENCE (3.05): a)SILT FENCE SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REPAIRS SHALL BE MADE IMMEDIATELY. b)SHOULD THE FABRIC ON A SILT FENCE DECOMPOSE OR BECOME INEFFECTIVE PRIOR TO THE END OF THE EXPECTED USABLE LIFE AND THE BARRIER STILL BE NECESSARY, THE FABRIC SHALL BE REPLACED PROMPTLY. c)SEDIMENT DEPOSITS SHOULD BE REMOVED AFTER EACH STORM EVENT. THEY MUST BE REMOVED WHEN DEPOSITS REACH APPROXIMATELY ONE-HALF THE HEIGHT OF THE BARRIER. d)ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE SILT FENCE IS NO LONGER REQUIRED SHALL BE DRESSED TO CONFORM WITH THE EXISTING GRADE, PREPARED AND SEEDED. 3.STORM DRAIN INLET PROTECTION (3.07/3.08): THE STRUCTURE SHALL BE INSPECTED AFTER EACH RAIN AND REPAIRS MADE AS NEEDED. SEDIMENT SHALL BE REMOVED AND THE TRAP RESTORED TO ITS ORIGINAL DIMENSIONS. REMOVED SEDIMENT SHALL BE DEPOSITED IN A SUITABLE AREA AND IN SUCH A MANNER THAT IT WILL NOT ERODE. STRUCTURES SHALL BE REMOVED AND THE AREA STABILIZED WHEN THE REMAINING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. 4.TREE PRESERVATION AND PROTECTION (3.38): IF THE SOIL HAS BEEN COMPACTED OVER THE ROOT ZONE OF ANY TREE, THE GROUND SHALL BE AERATED BY PUNCHING HOLES IN SOIL UNTIL LOOSENED. ANY DAMAGE TO THE CROWN, TRUNK, OR ROOT SYSTEM OF ANY TREE SHALL BE RETAINED IMMEDIATELY. STORMWATER NARRATIVE: THE SITE DISTURBANCE IS LESS THAN ONE (1) ACRE AND NOT PART OF A COMMON PLAN OF DEVELOPMENT. THEREFORE, PER SECTION 143-110, VIRGINIA STORMWATER MANAGEMENT PROGRAM (VSMP) LAND DISTURBANCE OR VSMP LAND-DISTURBING ACTIVITY, BULLET D, THE SITE DISTURBANCE IS NOT CLASSIFIED AS A STORMWATER LAND DISTURBING ACTIVITY AND IS NOT SUBJECT TO THE WATER QUALITY AND WATER QUANTITY REQUIREMENTS OF CHAPTER 143 OF THE FREDERICK COUNTY CODE. GEOLOGY: NO RECENT GEOTECHNICAL REPORT HAS BEEN PERFORMED FOR THIS SITE. CRITICAL AREAS: THERE ARE NO CRITICAL EROSION AREAS ON SITE. EROSION AND SEDIMENT CONTROL MEASURES: 1.CONSTRUCTION ENTRANCE (3.02) TO MINIMIZE THE AMOUNT OF SEDIMENT CARRIED FROM THE SITE ONTO PUBLIC AND PRIVATE ROADS. ONE (1) CONSTRUCTION ENTRANCE IS REQUIRED FOR ACCESS TO THE SITE. 2.SAFETY FENCE (3.01) TO PREVENT ACCESS TO AN EROSION CONTROL MEASURE. 3.SILT FENCE (3.05) TO FILTER RUNOFF FROM DISTURBED AREAS BEFORE IT LEAVES THE PROPERTY. SILT FENCE SHOULD BE REPLACED ON A REGULAR BASIS ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 4.STORM DRAIN INLET PROTECTION (3.07) TO MINIMIZE SILTATION OF EXISTING STORM SEWER INLETS WITHIN THE SITE. 5.CULVERT INLET PROTECTION (3.08) TO FILTER SEDIMENT AND PREVENT IT FROM ENTERING IN OR ACCUMULATING IN A STORM SEWER CULVERT. 6.PIPE OULET PROTECTION (3.18) TO PROTECT THE OUTLET STRUCTURE AND MINIMIZE DOWNSTREAM EROSION POTENTIAL BY REDUCING THE VELOCITY OF STORMWATER FLOWS. 7.TREE PROTECTION (3.38) TO PROTECT DESIRABLE TREES FROM LAND DISTURBING AND CONSTRUCTION ACTIVITIES. PERMANENT STABILIZATION: ALL AREAS TO BE LEFT UNCOVERED BY BUILDINGS OR PAVEMENT SHALL BE IMMEDIATELY STABILIZED WITH PERMANENT SEEDING FOLLOWING GRADING OPERATIONS. SEEDING SCHEDULE SHALL BE IN ACCORDANCE WITH THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK (VESCH). ANY VARIANCE FROM THESE MEASURES SHALL BE APPROVED BY THE LOCAL EROSION CONTROL AUTHORITY. VEGETATIVE PRACTICES: 1.TEMPORARY SEEDING (3.31) - ALL DENUDED AREAS THAT WILL NOT BE BROUGHT TO FINAL GRADE FOR A PERIOD OF MORE THAN 14 DAYS SHALL BE TEMPORARILY SEEDED. TEMPORARY SEEDING SCHEDULE TO BE IN ACCORDANCE WITH THE VESCH. 2.PERMANENT SEEDING (3.32) - ALL DENUDED AREAS SHALL BE RESEEDED, MULCHED, AND FERTILIZED AS NECESSARY OBTAIN PERENNIAL VEGETIVE COVER AFTER FINAL GRADING OPERATIONS. VEGETATIVE STABILIZATION SHALL BE UNIFORM, MATURE ENOUGH TO SURVIVE AND ADEQUATE TO INHIBIT EROSION. SOILS MAP (SCALE 1" = 500') PROJECT SITE 32B 32B 14B 5C 14B 39B VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3WxWxLP L P L P LP RBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 EX. SCUPPER EX. SCUPPER EX. CURB & GUTTER EX. CURB & GUTTER EX CONCRETE EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. RIP-RAP EX. WALK W/STEPS EX. SCUPPER EX. CONC. DUMPSTER PAD EX. HVAC EX. HVAC EX. SCREEN WALL RD RD RD RD RD RD RD RD RD RD RD EX. 6 EX. 7 EX. 8 EX. 9 EX. 10 INV.=716.74' INV.=718.12'12" HDPE12" HDPE12" HDPE 12" HDPE6"PVC 12" HDPE18" RCP EX. CONC. WALKSIGN WxWxINV.=716.02' N42°25'47"E 660.00' EX. 8" WATER LINE EX. 6" WATER LINE EX. 8" WATER LINE NO RECORD OF EXISTING EASEMENT SEE UTILITY PLAN AND PLAT OF EASEMENT FOR ESTABLISHMENT OF NEW EASEMENT 25' REAR YARD SETBACK 6" PVC 6" PVC 6" PVC FFE = 724.95' HEIGHT = +/-28.50'725730 735 740 735740740740735740 735 730725 725730735735 725720716720725725721 72 4 720 720 722 723 724 724725 726 724 722 719717LOC LOW LOC LOW LOW LOW LOC LOC LOC LOC LOC LOW WASH RACK TO STR. A = AC C = INLET 0.41 0.70 OP IP CIP CE TP TP TP TP SF TO STR. A = AC C = EX. 9 1.24 0.50 TO STR. A = AC C = EX. 9 0.63 0.90 TO STR. A = AC C = EX. 2 11.82 0.71 XXTP TP TP TP SAF SAF SAF SAF GRAPHICAL SCALE: 1" = 20' 20 10 0 20 40 60 EROSION AND SEDIMENT CONTROL PLAN PHASE 117 C-GC-101.DWG C-GC-101 1" = 20' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-GC-101.DWG, 5/23/2023 10:32 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 LG-ES1 EROSION/SEDIMENT CONTROL LEGEND NO. KEY SYMBOL DESCRIPTION CE SF3.05 3.02 SILT FENCE TEMPORARY GRAVEL CONSTRUCTION ENTRANCE X X X STORM DRAIN INLET PROTECTION3.07 IP OP3.18 OUTLET PROTECTION TREE PROTECTION3.38 TP LOC LIMITS OF CONSTRUCTION DRAINAGE DIVIDES CRITICAL SLOPE - CRITICAL SLOPE TO BE SEEDED, MULCHED AND TACKED WITHIN 14 DAYS AFTER START OF GRADING, OR SODDED AND PEGGED WITHIN 14 DAYS AFTER START SAF3.01 CONSTRUCTION SAFETY FENCE CULVERT INLET PROTECTION3.08 CIP E&S NOTES: 1.SEE SHEET 19 FOR EROSION AND SEDIMENT CONTROL DETAILS. 2.SEE SHEET 16 FOR EROSION AND SEDIMENT CONTROL NOTES. 3.CONTRACTOR TO ENSURE POSITIVE DRAINAGE AWAY FROM THE PROPERTY. 4.TREE PROTECTION TO BE INSTALLED ON ALL TREES TO REMAIN INSIDE OF THE LIMITS OF WORK. ADJUST CONSTRUCTION SAFETY FENCE AS NECESSARY TO PROVIDE TREE PROTECTION. 5.LIMITS OF WORK DENOTES CONTRACTOR LIMITS OF WORK INCLUDING STAGING, STORING, AND LAYDOWN MATERIALS. NO LAND DISTURBANCE IS PERMITTED OUTSIDE OF THE LIMITS OF CONSTRUCTION DELINEATED ON THIS SHEET. PS3.32 PS PERMANENT SEEDING VIRGIN I A S T A T E G R I D N O R T H - N A D 8 3 LP L P L P LP RBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 EX. SCUPPER EX. SCUPPER EX CONCRETE EX. ASPHALT EX. RIP-RAP EX. SCREEN WALL RD RD RD RD EX. 6 EX. 10 INV.=716.74'12" HDPE6"PVC 12" HDPE18" RCP SIGN WxWxINV.=716.02' N42°25'47"E 660.00' EX. 8" WATER LINE 25' REAR YARD SETBACK 6" PVC 6" PVC 6" PVC FFE = 724.95' HEIGHT = +/-28.50' 720 725730721 722 723 724726727728729731 TOP = 20.96' BOTTOM = 20.46' TOP = 21.53' BOTTOM = 21.03' TOP = 22.10' BOTTOM = 21.60' TOP = 22.67' BOTTOM = 22.17' TOP = 23.23' BOTTOM = 22.73' FFE = 724.95'WWWLOC LOW LOC LOW LOW LOW LOC LOC LOC LOC LOC LOW TO STR. A = AC C = RD3 0.07 0.90 CE TO STR. A = AC C = RD2 0.07 0.90 TO STR. A = AC C = RD4 0.07 0.90 TO STR. A = AC C = RD5 0.07 0.90 TO STR. A = AC C = RD6 0.07 0.90 TO STR. A = AC C = RD7 0.05 0.90 TO STR. A = AC C = 9 0.07 0.90 TO STR. A = AC C = 8 0.09 0.90 TO STR. A = AC C = EX. 10 0.36 0.30 TO STR. A = AC C = RD1 0.07 0.90 TO STR. A = AC C = EX. 10 0.09 0.90 TO STR. A = AC C = 9 0.21 0.33 TO STR. A = AC C = 8D 0.14 0.54 TO STR. A = AC C = TD6 0.02 0.90 TO STR. A = AC C = TD5 0.03 0.90 TO STR. A = AC C = TD4 0.03 0.90 TO STR. A = AC C = TD3 0.03 0.90 TO STR. A = AC C = TD2 0.03 0.90 TO STR. A = AC C = TD1 0.04 0.90 TO STR. A = AC C = INLET 0.59 0.62 TO STR. A = AC C = EX. 2 11.81 0.71 SF XXSAF SAF SAF SAF OP CIP TP TP TP TP TP TP TP WASH RACK IP IP PS PS PS PS PS PS PS GRAPHICAL SCALE: 1" = 20' 20 10 0 20 40 60 EROSION AND SEDIMENT CONTROL PLAN PHASE 218 C-GC-102.DWG C-GC-102 1" = 20' SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-GC-102.DWG, 5/23/2023 10:32 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 LG-ES1 EROSION/SEDIMENT CONTROL LEGEND NO. KEY SYMBOL DESCRIPTION CE SF3.05 3.02 SILT FENCE TEMPORARY GRAVEL CONSTRUCTION ENTRANCE X X X STORM DRAIN INLET PROTECTION3.07 IP OP3.18 OUTLET PROTECTION PS3.32 PS PERMANENT SEEDING TREE PROTECTION3.38 TP LOC LIMITS OF CONSTRUCTION DRAINAGE DIVIDES CRITICAL SLOPE - CRITICAL SLOPE TO BE SEEDED, MULCHED AND TACKED WITHIN 14 DAYS AFTER START OF GRADING, OR SODDED AND PEGGED WITHIN 14 DAYS AFTER START SAF3.01 CONSTRUCTION SAFETY FENCE CULVERT INLET PROTECTION3.08 CIP E&S NOTES: 1.SEE SHEET 19 FOR EROSION AND SEDIMENT CONTROL DETAILS. 2.SEE SHEET 16 FOR EROSION AND SEDIMENT CONTROL NOTES. 3.CONTRACTOR TO ENSURE POSITIVE DRAINAGE AWAY FROM THE PROPERTY. 4.TREE PROTECTION TO BE INSTALLED ON ALL TREES TO REMAIN INSIDE OF THE LIMITS OF WORK. ADJUST CONSTRUCTION SAFETY FENCE AS NECESSARY TO PROVIDE TREE PROTECTION. 5.LIMITS OF WORK DENOTES CONTRACTOR LIMITS OF WORK INCLUDING STAGING, STORING, AND LAYDOWN MATERIALS. NO LAND DISTURBANCE IS PERMITTED OUTSIDE OF THE LIMITS OF CONSTRUCTION DELINEATED ON THIS SHEET. 18" RCP10.59'4.5' 10'11.5' NOTES: 1.ROCK OUTLET PROTECTION DESIGNED PER PLATE 3.18-3 OF THE VESCH. CONSTRUCTION ROCK OUTLET PROTECTION AROUND EXISTING SCUPPER EROSION AND SEDIMENT CONTROL DETAILS19 C-GC-501.DWG C-GC-501 SBH BTV BTV CEK G:\PROJECT\ENGIN\3611\0101\PLANS\C-GC-501.DWG, 5/23/2023 10:33 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: CONSTRUCTION SAFETY FENCEANOT TO SCALE CULVERT INLET PROTECTIONENOT TO SCALE Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 CONSTRUCTION ENTRANCEBNOT TO SCALE SILT FENCECNOT TO SCALE INLET PROTECTIONDNOT TO SCALE TREE PROTECTIONGNOT TO SCALE PIPE OUTLET PROTECTIONFNOT TO SCALE CAF CE SF IP TPOPCIP ROCK OUTLET PROTECTIONHSCALE: 1" = 10' TYSON DRIVE - ROUTE 86380' RIGHT-OF-WAY DB. 733 PG. 517SA CO MBMB MBLP MBMBLPLPLPLPLPLPLPLPLP 24" CMP15" HD P E24" HDPECTELBXTRTRTREX.1EX.2EX.3EX.4EX.5EX.624" RCPEX.1012" HDPE6"PVC12" HDPE12" HDPE18" HDPE18" RCPWVAC ACACCEACESIGNSIGNSIGNWx W xWxWx6" PVC6" PVC6" PVCLOCLOCLOC LOCLOC LOC LOCSFSC F SC F C F C F C F DA-1 DA-1A SYMBOL LEGEND LIMITS OF DISTURBANCE DRAINAGE DIVIDE TIME OF CONCENTRATION: SF = SHEETFLOW SCF= SHALLOW CONCENTRATED FLOW CF = CONCENTRATED FLOW SF DRAINAGE AREA SUB DRAINAGE DIVIDE DESCRIPTION REACH LINES DA ADEQUATE OUTFALL ANALYSIS20 C-CJ-101.DWG C-CJ-101 1" = 30' ---- GORDON B. VELLOZZI B. VELLOZZI C. KINGSLAND G:\PROJECT\ENGIN\3611\0101\PLANS\C-CJ-101.DWG, 5/23/2023 10:33 AM, bvellozzi VERT. DATUM: HORIZ. DATUM: Gordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 REACH 1 OUTFALL 1 DRAINAGE AREA APPROXIMATE AREA = 69.20 AC LIMITS OF ANALYSIS ADEQUATE OUTFALL ANALYSIS NOTE: BACKGROUND INFORMATION IS OBTAINED FROM FREDERICK COUNTY TAX MAP DATA OUTFALL SCHEMATIC OFF-SITE DRAINAGE PROJECT SITE (OUTFALL 1) OVERLAND WOODED FLOW (REACH 3) CULVERT TO TYSON DRIVE (REACH 4) 18" CULVERT (REACH 2) RIP-RAP CHANNEL (REACH 1) STILLING BASIN (LIMITS OF ANALYSIS) REACH 2 REACH 3 REACH 4 REACH 4A EXISTING STILLING BASIN LIMITS OF ANALYSIS OUTFALL 1 OVERALL DRAINAGE AREAA DRAINAGE DIVIDES & OUTFALL ANALYSIS REACHESB C-VALUE, Tc & FLOW COMPUTATIONSC ADEQUATE OUTFALL DESCRIPTION FOR COMPLIANCE WITH ADEQUATE OUTFALL REQUIREMENTS PER MINIMUM STANDARD MS-19. THE FOLLOWING ANALYSIS IS PROVIDED. THE SITE IS DEFINED BY THE STORMWATER MANAGEMENT (SWM) LIMITS OF DISTURBANCE (LOD) OF APPROXIMATELY 0.60 ACRES. THE LIMITS OF ANALYSIS ARE PROVIDED AT THE CONFLUENCE OF APPROXIMATELY 69.20 ACRES OF DRAINAGE AREA IN A ROCK LINED STILLING BASIN BETWEEN TYSONS DRIVE AND THE PROPERTY. THE POINT OF ANALYSIS IS 100 TIMES GREATER THAN THE CONTRIBUTING LOD. RUNOFF IS CONVEYED FROM THE LIMITS OF DISTURBANCE OVER FIVE (5) REACHES. FLOW IS SPLIT BETWEEN THE FINAL TWO REACHES DURING THE 10-YEAR RAINFALL EVENT. SEPARATE FLOW RATES FOR THE 10-YEAR STORM ARE PROVIDED FOR REACHES ONE (1) AND TWO (2) AS THEY RECEIVE DIRECT RUNOFF FROM 2.25 ACRES INCLUDING PARKING LOT AND ROOF TOP RUNOFF. DOWNSTREAM, THE FLOW RATES ARE ANALYZED FOR REACHES 3, 4, AND 4A FOR THE LARGER 11.79 ACRE DRAINAGE SHED. PER MS-19, THE ADEQUACY OF ALL PREVIOUSLY CONSTRUCTED MAN MADE CHANNELS AND STORM PIPES WAS ANALYZED USING THE 10-YEAR 24-DURATION STORM. THE USE OF THE 10-YEAR STORM WAS ALSO UTILIZED TO DEMONSTRATE NON EROSIVE VELOCITIES IN CHANNELS. REACH 1 CALCULATIONSD REACH 2 CALCULATIONSE REACH 3 CALCULATIONS REACH 4A CALCULATIONSH REACH 4 CALCULATIONSG GRAPHICAL SCALE: 1" = 100' 100 50 0 100 200 300 GRAPHICAL SCALE: 1" = 300' 300 150 0 300 600 900 EMBANKMENT (REACH 4A) APPROXIMATE PROPOSED DISTURBED AREA = 0.60 ACRES ADEQUATE OUTFALL RESULTS REACH 1: THE SITE OUTFALLS AT THE EDGE OF THE PARKING LOT (OUTFALL 1) INTO AN EXISTING RIPRAP TRAPEZOIDAL CHANNEL WITH 9"-12" ROCK LINING. RIP RAP CHANNEL EXTENDS TO AN EXISTING 18" CULVERT. DURING A 10-YEAR STORM WITH A FLOW RATE OF 10.63 CFS, THE 1.5 FEET DEEP CHANNEL FILLS TO 0.69 FEET DEEP AND THE RUNOFF HAS A VELOCITY OF 4.75 FPS. PER THE VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT) DRAINAGE MANUAL, THE RIPRAP CHANNEL IS STABLE UP TO 8.6 FPS. REACH 1 IS STABLE AND ADEQUATE. REACH 2: APPROXIMATELY 49 FEET OF RCP FROM THE OPENING OF THE EXISTING 18" CULVERT TO THE OUTFALL IN AN EXISTING MANMADE WOODED DRAINAGE CHANNEL. DURING A 10-YEAR STORM WITH A FLOW RATE OF 10.63 CFS, THE FLOW DOES NOT OVERTOP THE EMBANKMENT ABOVE AND VELOCITY AT THE OUTFALL IS 6.26 FPS. A TREE OBSTRUCTING THE OUTFALL OF THE EMBANKMENT SHALL BE REMOVED AND ROCK OUTLET PROTECTION PROVIDED TO STABILIZE THE PIPE OUTFALL TO THE WOODED DRAINAGE CHANNEL. AFTER INSTALLATION OF ROCK OUTLET PROTECTION, REACH 2 IS STABLE AND ADEQUATE. REACH 3: FROM THE END OF THE EXISTING 18" CULVERT, THROUGH A FLAT MANMADE HEAVILY VEGETATED CHANNEL TO THE OPENING OF AN EXISTING 24" CMP CULVERT. DURING A 10-YEAR STORM WITH A FLOW RATE OF 35.69 CFS, THE 3 FEET DEEP CHANNEL FILLS TO 1.33 FEET DEEP AND THE RUNOFF HAS A VELOCITY OF 0.76 FPS. PER THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK (VESCH), HEAVILY VEGETATED CHANNELS WITH A SLOPE OF 0-5.00% ARE STABLE UP TO 3.00 FPS. REACH 3 IS STABLE AND ADEQUATE. REACH 4: APPROXIMATELY 49 FEET OF CMP FROM THE OPENING OF THE EXISTING 24" CULVERT TO THE OUTFALL IN THE ROCK LINED STILLING BASIN. DURING A 10-YEAR STORM WITH A FLOW RATE OF 35.69 CFS, THE CULVERT FLOWS FULL AND PASSES 27.64 CFS AT 8.94 FPS. THE DOWNSTREAM STILLING BASIN IS ADEQUATELY ARMORED TO RECEIVE THE 10-YEAR FLOW. THE BYPASSING 8.05 CFS OVERTOPS AN EARTHEN EMBANKMENT (REACH 4A) AND DISCHARGES TO THE STILLING BASIN. REACH 4A: AN APPROXIMATELY 20 FEET WIDE MANMADE EMBANKMENT DENSELY VEGETATED CONVEYS A PORTION OF THE 10-YEAR STORM EVENT TO THE STILLING BASIN. THE VELOCITY OF THE 8.05 CFS OVER THE 5:1 SLOPES DOWNSTREAM SIDE OF THE EMBANKMENT IS APPROXIMATELY 4.47 FPS. THE DENSELY VEGETATED SLOPE IS STABLE UP TO 5.0 FPS. REACH CAPACITY COMPUTATIONS REACH 4A DENSE VEGETATIONI F VIRGI N I A S T A T E G R I D N O R T H - N A D 8 3 719718 718717 718 719 720 721 722 723 724725 725720720722723724720722723724723724 725 728 729725 724725732730724 725 730 735 735 732 732 734 735736732725730 735 740 740 740 735 741 745740735735740740740735740 735 730725 725730735740745739738735730730735 735 740 740 73 5 730 727725 725720729 730 716717717720725 724720720720716716718719720720720725725721 72 4 720 720 722 723 724 724725 726 724 722 719719718720715715719 720718718720 718717715715718719717 714 715 716 718 718 717 717 718 718 715 715 720720 7 2 1 722 724 723 723 722 724 721 724 722 716 719 718 720 716 716 720 714 714 715 715 716 717 715 714 715 713 714 717IPF IPF IPF RBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 TYSON DRIVE - ROUTE 863 80' RIGHT-OF-WAY DB. 733 PG. 517 MB MBMB MB LP MBMB LP LP LP LP LP LP LP LP LP OHERBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 INV.=713.35' INV.=713.02' INV.=712.84'INV.=713.22' INV.=713.15' INV.=712.11' INV.=711.96' INV.=712.26' INV.=714.07' INV.=715.04'INV.=714.98' INV.=713.45' INV.=712.78' INV.=712.88'24" CMP(3)-48" CMP 15" H D P E 24" HDPE INV.=714.14' C TEL BX TR TR TR TR TR EX. EDGE OF PAVEMENTEX. EDGE OF PAVEMENTEX. EDGE OF PAVEMENT EX. EDGE OF PAVEMENT EX. EDGE OF PAVEMENT EX. CONC. WALK EX. CONC. WALKEX. CONC. WALKEX. CONC. WALKEX. HEADWALL EX. HEADWALL EX. HEADWALL EX. HEADWALL EX. CONC.EX. CONC.EX. CONC.EX. CONC.EX. RIP-RAP EX. CURB & GUTTER EX. CURB & GUTTER EX. CURB & GUTTEREX. EDGE OF PAVEMENTEX. CURB & GUTTEREX. SCUPPER EX. SCUPPER EX. SCUPPER EX. SCUPPER EX. SCUPPER EX. SCUPPER EX. SCUPPER EX. SCUPPER EX. HEADER CURB (TYPICAL) EX CONCRETE EX CONCRETE EX CONCRETE EX CONCRETE APRON EX CONCRETE APRON EX CONCRETE EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. CONCRETE EX. RIP-RAP EX. RIP-RAP EX. RIP-RAP EX. RIP-RAP EX. CONC. DITCH EX. CONC. DITCH EX. CONC. DITCH EX. HEADWALL EX. CULVERT EX. RIP-RAP EX. RIP-RAP EX. CURB & GUTTER EX. EDGE OF PAVEMENT EX. EDGE OF PAVEMENT EX. EDGE OF PAVEMENT EX. EDGE OF PAVEMENT EX. EDGE OF PAVEMENTEX. SCREEN WALL TEL BX EX. EDGE OF PAVEMENTEX. EDGE OF PAVEMENTRD RD RD RD TOP=717.34 EX.1 EX.2 EX.3 EX.4 EX.5 EX.6 24" RCP EX.10 INV.=716.74' INV.=718.12'12" HDPE6"PVC 12" HDPE12" HDPE18" HDP E 18" RCP WV ACACAC EX. TRASH ENCLOSURE W/DUMPSTER C E TR E AC E SIGN SIGN SIGN LOT 14 STONEWALL INDUSTRIAL PARK JONES MANAGEMENT ASSOCIATES 4.1667 ACRES MAP #43-19-29 INSTR. #090000242 ZONING - M1 LOT 6 STONEWALL INDUSTRIAL PARK DONALD G. SOWERS4.1667 ACRES 2.5000 ACRES MAP #43-19-58 INSTR. #050008976 ZONING - M1 LOT 4 STONEWALL INDUSTRIAL PARK LAKEVILLE CIRCLE LLC C/O TRANFORM DEVELOPMENT 2.6752 ACRES MAP #43-19-58 INSTR. #050008976 ZONING - M1 LOT 7 STONEWALL INDUSTRIAL PARK PERRY FAMILY PARTNERS IV LLC 3.159 ACRES MAP #43-19-59 INSTR. #130000701 ZONING - M1 LOT 7A STONEWALL INDUSTRIAL PARK RESS PROPERTIES LLC 2.000 ACRES MAP #43-19-59A INSTR. #070003537 ZONING - M1 LOT 8-A STONEWALL INDUSTRIAL PARK LOKEY ENTERPRISES LLC 4.100 ACRES MAP #43-19-62 INSTR. #100008447 ZONING - M1 LOT 35 STONEWALL INDUSTRIAL PARK TMME INVESTMENTS LLC 4.7274 ACRES MAP #43-19-61 INSTR. #050018483 ZONING - M1 LOT 14 STONEWALL INDUSTRIAL PARK JONES MANAGEMENT ASSOCIATES 4.1667 ACRES MAP #43-19-29 INSTR. #090000242 ZONING - M1 LOT 35 STONEWALL INDUSTRIAL PARK TMME INVESTMENTS LLC 4.7274 ACRES MAP #43-19-61 INSTR. #050018483 ZONING - M1 WxWxWxINV.=716.02'N47°34'13"W 990.00'S42°25'47"W 660.00' N42°25'47"E 660.00'S47°34'13"E 990.00'EX. 8" WATER LINE EX. 8" WATER LINE EX. 8" WATER LINE 75' FRONT YARD SETBACK 25' REAR YARD SETBACK 25' SIDE YARD SETBACK25' SIDE YARD SETBACKWx Wx Wx Wx WxWxWxWx6" PVC 6" PVC 6" PVC FFE = 724.95' HEIGHT = +/-28.50' FFE = 724.95' 720 725730721 722 723 724726727728729731 TOP = 20.96' BOTTOM = 20.46' TOP = 21.53' BOTTOM = 21.03' TOP = 22.10' BOTTOM = 21.60' TOP = 22.67' BOTTOM = 22.17' TOP = 23.23' BOTTOM = 22.73' (1) GB 3" Cal. (1) GB 3" Cal. (2) QC 3" Cal. (2) NS 3" Cal. (3) LS 3" Cal. (3) QP 3" Cal. (3) AR 3" Cal. (3) QP 3" Cal. (3) TA 3" Cal. (3) NS 3" Cal. (3) QC 3" Cal. (3) AR 3" Cal. (3) QC 3" Cal. (3) TA 3" Cal. (3) NS 3" Cal. (2) QP 3" Cal. (3) QP 3" Cal. (3) NS 3" Cal. (3) QC 3" Cal. (2) AR 3" Cal. (2) QP 3" Cal. (3) TA 3" Cal. (2) QP 3" Cal. (2) AR 3" Cal. (2) TA 3" Cal. (1) GB 3" Cal. (1) GB 3" Cal. (1) GB 3" Cal. (1) GB 3" Cal. (4) LS 3" Cal. LEGEND IMPERVIOUS SURFACE PARKING AREA PROPOSED TREE PROPOSED INTERIOR PARKING TREE EXISTING INTERIOR PARKING TREE LANDSCAPE PLAN OVERALL21 L-LS-101.DWG L-LS-101 1" = 60' N/A GORDON A. EITLER D. KOESER D. KOESERGordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 SHEET 22 SHEET 23 GRAPHICAL SCALE: 1" = 60' 60 30 0 60 120 180 LAN DSCAPE A R C H ITECTLic. No. 000851 DOUGLAS L. KOESERCOMMONWEALTHOF VI R GI NIA 724 729725 724725732730724 725 730 735 735 732 732 734 735736732725730 735 740 740 740 735 741745735740740740735740 735 730725 725730735745730735 725720716717717720725 720720725725721 72 4 720 720 722 723 724 724725 726 724 722 719719718717IPF RBG TYSON ASSOCIATES LLC & LP L P LP LP LP RBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 TR TREX. SCUPPER EX. SCUPPER EX. SCUPPER EX CONCRETE EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. RIP-RAP EX. RIP-RAP EX. CONC. DITCH EX. CONC. DITCH EX. CONC. DITCH EX. HEADWALL EX. CULVERT EX. SCREEN WALL RD RD RD RD EX. 5 EX. 6 EX. 10 INV.=716.74' INV.=718.12'12" HDPE6"PVC 12" HDPE18" RCP C E AC E SIGN LOT 6 STONEWALL INDUSTRIAL PARK DONALD G. SOWERS4.1667 ACRES 2.5000 ACRES MAP #43-19-58 INSTR. #050008976 ZONING - M1 LOT 7 STONEWALL INDUSTRIAL PARK PERRY FAMILY PARTNERS IV LLC 3.159 ACRES MAP #43-19-59 INSTR. #130000701 ZONING - M1 LOT 7A STONEWALL INDUSTRIAL PARK RESS PROPERTIES LLC 2.000 ACRES MAP #43-19-59A INSTR. #070003537 ZONING - M1 WxWxINV.=716.02' N42°25'47"E 660.00' EX. 8" WATER LINE 25' REAR YARD SETBACK 25' SIDE YARD SETBACK25' SIDE YARD SETBACKWxWxWx6" PVC 6" PVC 6" PVC FFE = 724.95' HEIGHT = +/-28.50' FFE = 724.95' 720 725730721 722 723 724726727728729731 TOP = 20.96' BOTTOM = 20.46' TOP = 21.53' BOTTOM = 21.03' TOP = 22.10' BOTTOM = 21.60' TOP = 22.67' BOTTOM = 22.17' TOP = 23.23' BOTTOM = 22.73' (1) GB 3" Cal. (1) GB 3" Cal. (2) QC 3" Cal. (2) NS 3" Cal. (3) LS 3" Cal. (3) QP 3" Cal. (3) AR 3" Cal. (3) QP 3" Cal. (3) TA 3" Cal. (3) NS 3" Cal. (3) QC 3" Cal. (3) AR 3" Cal. (2) TA 3" Cal. (1) GB 3" Cal. (1) GB 3" Cal. LEGEND IMPERVIOUS SURFACE PARKING AREA PROPOSED TREE PROPOSED INTERIOR PARKING TREE EXISTING INTERIOR PARKING TREE VIRGI N I A S T A T E G R I D N O R T H - N A D 8 3LANDSCAPE PLAN22 L-LS-101.DWG L-LS-101 1" = 30' N/A GORDON A. EITLER D. KOESER D. KOESERGordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 MATCH LINE SEE SHEET 23 GRAPHICAL SCALE: 1" = 30' 30 15 0 30 60 90 LAN DSCAPE A R C H ITECTLic. No. 000851 DOUGLAS L. KOESERCOMMONWEALTHOF VI R GI NIA 719718 718717 718 719 720 721 722 723 7 2 4 725 725720720724720722723724723717717720720720716716718719720720719718715715719 720718718718717715715718719717 714 715 716 718 718 717 717 718 718 715 715 720720 7 2 1 722 724 723 723 722 724 721 724 722 716 718720716 716 720 714 714 715 715 716 717715 714 715 713 714 IPFIPF RBG TYSON ASSOCIATES LLC & C/O RBG HOLDINGS LLC 15.0000 ACRES MAP #43-19-31 INSTR. #210020281 ZONING - M1 TYSON DRIVE - ROUTE 863 80' RIGHT-OF-WAY DB. 733 PG. 517 MB MBMB MB LP MBMB L P LP LP LP OHEOHEOHEINV.=713.35' INV.=713.02' INV.=712.84'INV.=713.22' INV.=713.15' INV.=712.26'24" CMP(3)-48" CMP INV.=714.14' C TEL BX TR TR TR TR EX. EDGE OF PAVEMENT EX. EDGE OF PAVEMENT EX. EDGE OF PAVEMENT EX. EDGE OF PAVEMENT EX. CONC. WALK EX. CONC. WALKEX. CONC. WALKEX. CONC. WALKEX. HEADWALL EX. HEADWALL EX. HEADWALL EX. HEADWALL EX. CONC.EX. CONC.EX. CONC.EX. CONC.EX. RIP-RAP EX. CURB & GUTTER EX. CURB & GUTTER EX. CURB & GUTTEREX. EDGE OF PAVEMENTEX. CURB & GUTTEREX. SCUPPER EX. SCUPPER EX. SCUPPER EX. SCUPPER EX. SCUPPER EX. SCUPPER EX. HEADER CURB (TYPICAL) EX CONCRETE EX CONCRETE EX CONCRETE APRON EX CONCRETE APRON EX CONCRETE EX. ASPHALT EX. ASPHALT EX. ASPHALT EX. CONCRETE EX. RIP-RAP EX. CONC. DITCH TEL BX TOP=717.34 EX. 3 EX. 4 EX. 5 12" HDPE18" HDPE WV ACACAC TR E AC E SIGN SIGN WxWxWxWxWxN47°34'13"W 990.00'S42°25'47"W 660.00'S47°34'13"E 990.00'EX. 8" WATER LINE EX. 8" WATER LINE 75' FRONT YARD SETBACK 25' SIDE YARD SETBACK25' SIDE YARD SETBACKWx Wx Wx Wx Wx Wx Wx Wx WxWxWxWxWxWx(3) AR 3" Cal. (3) QC 3" Cal. (3) TA 3" Cal. (3) NS 3" Cal. (2) QP 3" Cal. (3) QP 3" Cal. (3) NS 3" Cal. (3) QC 3" Cal. (2) AR 3" Cal. (2) QP 3" Cal. (3) TA 3" Cal. (2) QP 3" Cal. (2) AR 3" Cal. (1) GB 3" Cal. (1) GB 3" Cal. (4) LS 3" Cal. LEGEND IMPERVIOUS SURFACE PARKING AREA PROPOSED TREE PROPOSED INTERIOR PARKING TREE EXISTING INTERIOR PARKING TREE VIRGI N I A S T A T E G R I D N O R T H - N A D 8 3LANDSCAPE PLAN23 L-LS-101.DWG L-LS-101 1" = 30' N/A GORDON A. EITLER D. KOESER D. KOESERGordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 MATCH LINE SEE SHEET 22 GRAPHICAL SCALE: 1" = 30' 30 15 0 30 60 90 LAN DSCAPE A R C H ITECTLic. No. 000851 DOUGLAS L. KOESERCOMMONWEALTHOF VI R GI NIA PLANTING HOLE 2-3X WIDTH OF ROOT BALL SOIL PEDESTAL UNDISTURBED NOTES: 1. STAKING AND GUYING MAY BE REQUIRED TO COUNTER HIGH WINDS, SOIL SETTLEMENT, STEEP SLOPES, VANDALISM, OR OTHER CONDITIONS THREATENING TREE HEALTH OR SUITABLE GROWTH PATTERNS. 2. AT TIME OF PLANTING PRUNE ONLY CROSSING LIMBS, BROKEN OR DEAD BRANCHES, AND ANY BRANCHES THAT POSE A HAZARD TO PEDESTRIANS. 3" (7.5 CM) TEMPORARY SOIL SAUCER TOP OF ROOTBALL TO BE SET 10% ABOVE THE LEVEL OF SURROUNDING SOIL REMOVE ALL WIRE, PLASTIC, ROPE, AND BURLAP (NATURAL AND SYNTHETIC) FROM TOP HALF OF ROOT BALL AND FROM SITE. IF CONTAINER GOWN, REMOVE CONTAINER AND CUT CIRCLING ROOTS. BACKFILL WITH 1/2 CLEAN EXISTING SOIL, 1/4 CERTIFIED TOPSOIL, AND 1/4 ORGANIC MATERIAL APPROVED BY THE LANDSCAPE ARCHITECT REMOVE TAGS, LABELS, AND PLASTIC SLEEVING. DO NOT STAKE UNLESS SPECIFIED (SEE NOTE). DO NOT WRAP TRUNK. PRUNE SUCKERS 3" (7.5 CM) MULCH, DO NOT PLACE MULCH ADJACENT TO TRUNK THREE STRANDS OF GALVANIZED WIRE GUY 12 GAUGE. ALLOW FOR SLIGHT AMOUNT OF MOVEMENT. 8 FT x 2 IN x 2 IN (2.4 M x 5 CM x 5 CM) HARDWOOD STAKE, 2 FT-6 IN (0.8 M) MIN. BELOW SURFACE. STAKE SHALL BE DRIVEN A MIN. 18 IN (46 CM) OUT FROM TRUNK AND OUTSIDE OF ROOTBALL. INCORPORATE SLOW-RELEASE GRANULAR FERTILIZER PLAN VIEW OF GUYING WIRE LAYOUT 12 GAUGE GALVANIZED WIRE THREE 2 IN x 2 IN (5 CM x 5 CM) HARDWOOD STAKES DECIDUOUS TREE PLANTING DETAIL LANDSCAPE CALCULATIONS AND DETAILS24 L-LS-101.DWG L-LS-101 1" = 20' GORDON A. EITLER D. KOESER D. KOESERGordon4501 Daly DriveChantilly, VA 20151Phone: 703-263-1900www.gordon.us.comPROGRAMMING AND PLANNINGCIVIL ENGINEERINGLANDSCAPE ARCHITECTURESURVEY AND MAPPINGSECURITY CONSULTINGCOPYRIGHT . NO REPRODUCTION OR USE OF THIS DRAWING IS ALLOWED IN PART OR IN WHOLE BY ANY PROCESS WITHOUT PRIOR WRITTEN AUTHORIZATION FROM GORDON US, LLC (GORDON)REVISIONS NUMBER DATE DESCRIPTIONSEAL: NUMBER: NCS: CADD: JOB: PLAN: HORIZ: VERT: Gordon SCALE: DATE: SUR: DRW: DES: CHK:####310 TYSON DRIVEFINAL SITE PLAN310 TYSON DRIVEFREDERICK COUNTY, VIRGINIA24 3611-0101 FINAL SITE PLAN MAY 23, 2023 LANDSCAPE PLANTING DETAILS NOTES: 1.THERE IS NO BUFFER REQUIREMENT FOR THIS SITE, DUE TO ADJACENT PARCELS BEING ZONED M1, RESULTING IN AN M1 TO M1 LAND USE BUFFER. 2.ALL LANDSCAPING WILL CONFORM TO THE REQUIREMENTS AND BE IN GENERAL CONFORMANCE WITH THE FREDERICK COUNTY ZONING ORDINANCE §165-203.01B 3.NO TREES OR SHRUBS SHALL BE PLACED ON FREDERICK WATER EASEMENTS.LAN DSCAPE A R C H ITECTLic. No. 000851 DOUGLAS L. KOESERCOMMONWEALTHOF VI R GI NIA