Loading...
HomeMy WebLinkAbout42-22 Site PlanWINCHESTER SECURE STORAGE SITE PLAN (SP #42-22) FREDERICK COUNTY, VIRGINIA LOCATION MAP: PROJECT INFORMATION:SHEET INDEX: PROJECT NOTES: SCALE: 1" = 1000' PROJECT LOCATION SHEET DESCRIPTION SHEET NUMBER COVER SHEET....................................................................................... GENERAL NOTES................................................................................... EXISTING CONDITIONS......................................................................... INITIAL E&SC PLAN................................................................................ DEMOLITION PLAN................................................................................ SITE PLAN............................................................................................... UTILITY PLAN......................................................................................... FINAL E&SC PLAN.................................................................................. GRADING PLAN...................................................................................... LANDSCAPE PLAN................................................................................. LIFE SAFETY PLAN................................................................................ LIGHTING PLAN...................................................................................... ENTRANCE PLAN................................................................................... PRE-DEVELOPED STORMWATER MANAGEMENT PLAN................... POST-DEVELOPED STORMWATER MANAGEMENT PLAN................ POST-DEVELOPED STORMWATER MANAGEMENT PLAN................ STORM SEWER PROFILES................................................................... WATERLINE PLAN & PROFILE.............................................................. WATERLINE AND SANITARY SEWER PLAN & PROFILE.................... UTILITY DETAILS.................................................................................... LIGHTING DETAILS................................................................................ LIGHTING DETAILS................................................................................ E&SC NOTES.......................................................................................... E&SC DETAILS........................................................................................ E&SC AND SWM DETAILS..................................................................... CONSTRUCTION DETAILS.................................................................... CONSTRUCTION DETAILS.................................................................... CONSTRUCTION DETAILS.................................................................... CONSTRUCTION DETAILS.................................................................... CONSTRUCTION DETAILS.................................................................... C-01 C-02 C-03 C-04 C-05 C-06 C-07 C-08 C-09 C-10 C-11 C-12 C-13 C-14 C-15 C-16 C-17 C-18 C-19 C-20 C-21 C-22 C-23 C-24 C-25 C-26 C-27 C-28 C-29 C-30VA STATEGRID NORTHCURRENT OWNER: REFERENCE: PREVIOUS APPROVALS: USE DESCRIPTION: ACREAGE: ZONING: PHYSICAL ADDRESS: DISTURBED AREA: FLOODPLAIN: WINCHESTER SECURE STORAGE, LLC TM 53A-A-1 STONEWALL MAGISTERIAL DISTRICT SELF STORAGE 4.15 AC. B2 1350 NORTH FREDERICK PIKE 3.59 ACRES OUTSIDE 100 YEAR FLOODPLAIN BASED ON FIRM MAP PANEL 51069C0208E, DATED JANUARY 29, 2021 PROJECT CONTACTS: OWNER/DEVELOPER: ADDRESS- PHONE NUMBER- E-MAIL- CONTACT- CONTRACTOR: ADDRESS- PHONE NUMBER- E-MAIL- CONTACT- ARCHITECT: ADDRESS- PHONE NUMBER- E-MAIL- CONTACT- ENGINEER (CIVIL): ADDRESS- PHONE NUMBER- E-MAIL- CONTACT- WINCHESTER SECURE STORAGE, LLC 21 SOUTH LOUDOUN ST. WINCHESTER, VA 22601 (540) 247-6218 SCOTT@HIATTRUN.COM SCOTT ROSENFELD TBD TBD DICE ENGINEERING, PLC 101 SHELBY CT. WINCHESTER, VA 22602 (540) 974-5157 (540) 723-4868 DDUNLAP@DICE-ENG.COM DENNIE DUNLAP ELECTRIC COMPANY: ADDRESS- PHONE NUMBER- CONTACT- WATER PROVIDER: ADDRESS- PHONE NUMBER- CONTACT- SEWER PROVIDER: ADDRESS- PHONE NUMBER- CONTACT- GAS COMPANY: ADDRESS- PHONE NUMBER- CONTACT- PHONE COMPANY: ADDRESS- PHONE NUMBER- CONTACT- RAPPAHANNOCK ELECTRIC CO-OP 137 KELLEY COURT FRONT ROYAL, VA 22630 (540) 622-5138 FREDERICK WATER P.O. BOX 1877 WINCHESTER, VA 22604 (540) 868-1061 FREDERICK WATER P.O. BOX 1877 WINCHESTER, VA 22604 (540) 868-1061 SHENANDOAH GAS 350 HILLANDALE LANE WINCHESTER, VA 22602 (540) 868-7925 VERIZON 404 HILLANDALE LANE WINCHESTER, VA 22602 (540) 665-3153 CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYCOVER SHEETJOB NO.: 22-01 C-01C-01.DWGDDDN/ADDDWINCHESTER SECURE STORAGEFREDERICK COUNTY, VADESCRIPTION06-28-202202-01-2023 BUILDING DEPT. NOTES: 1. 2. 3. 4. 5. 6. RESPONSIBLE LAND DISTURBER NAME: TIMOTHY SMITH CONTACT INFO:P.O. BOX 974 MARTINSBURG, WV 25402 (304) 229-6515 (PHONE) CERTIFICATION #: RLD09826 EXP. DATE: 06/08/2024 THE RESPONSIBLE LAND DISTURBER IS THE PARTY RESPONSIBLE FOR CARRYING OUT THE LAND DISTURBING ACTIVITY AS SET FORTH IN THE PLANS.1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYGENERAL NOTESJOB NO.: 22-01 C-02C-02.DWGDDDN/ADDDV . V2. V3. V4 V5. V6. V7. V9. V10. V11. V12. V13. V14. V15. V17. V18. V19. V20. V21. V22. V23. V24. V25.DESCRIPTION06-28-202202-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VA1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYEXISTING CONDITIONSJOB NO.: 22-01 C-03C-03.DWGDDD1" = 20'DDDDESCRIPTION06-28-20221 inch = ft. ( IN FEET ) GRAPHIC SCALE 20 02-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VAMATCHLINE -- THIS SHEET MATCHLINE -- THIS SHEET MATCHLINE -- THIS SHEET 1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22 HATCHED AREA REPRESENTS PROPOSED 20' FREDERICK WATER ESM'T 20'302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYDEMOLITION PLANJOB NO.: 22-01 C-04C-04.DWGDDD1" = 20'DDDDESCRIPTION06-28-20221 inch = ft. ( IN FEET ) GRAPHIC SCALE 20 02-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VA(T.B.R.) (T.B.R.) (T.B.R.)(T.B.R.) (T.B.R.) (T.B.R.) (T.B.R.)(T.B .R .)(T.B.R.) REMOVE EX. ASPHALT PAVEMENT WITHIN HATCHED AREA REMOVE EX. ASPHALT PAVEMENT WITHIN HATCHED AREA NOTES: 1.T.B.R. = TO BE REMOVED. 2.EXISTING WELL AND SEPTIC SYSTEMS TO BE CLOSED IN ACCORDANCE WITH FREDERICK COUNTY HEALTH DEPARTMENT REGULATIONS. (TO BE CLOSED) EX. VEGETATION TO BE REMOVED WITHIN HATCHED AREA EX. VEGETATION TO BE REMOVED WITHIN HATCHED AREA (T.B.R.)(T .B .R . ) (T.B.R.)(T.B.R.) (T.B.R.)(T.B.R.)SAWCUT AND REMOVE EXISTING PAVEMENT 12" MIN. FROM EDGE AND AS INDICATED BY HATCHING AT EXISTING ENTRANCES ERADICATE EXISTING EDGE / LANE LINE WITHIN CLOUDED AREA REMOVE EXISTING WATERLINE WITHIN CLOUDED AREA (SEE SHEET C-07)1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22 (T.B.R.) (T.B.R.)302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTSHATCHING DEPICTS POTENTIAL AREA OF MILLING & OVERLAY OF ADJACENT TRAVEL LANE PER DIRECTION OF VDOT INSPECTOR CE CIP CIPSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFS F SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SF SF SF SF SF SFSFSFSFSB TEMPORARY TOPSOIL STOCKPILE SF SF SF SF SF SF SF SF SF DD DD DD DD DD DD DD DD DD DD DD DD DD DD DD 788 784 790 784 790 SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF DD DD SF SF SF SFSFSFS F SF SFSFSF IP RR CIP CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYINITIAL E&SC PLANJOB NO.: 22-01 C-05C-05.DWGDDD1" = 20'DDDDESCRIPTION06-28-20221 inch = ft. ( IN FEET ) GRAPHIC SCALE 20 02-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VADRAINAGE AREA TO SB = 3.03 AC. REQ'D WET STORAGE VOL. = 5,481 CU. FT. TOTAL REQ'D STORAGE VOL. = 10,962 CU. FT. TOP EMBANKMENT ELEV. = 790.50 EMERGENCY SPILLWAY ELEV. = 788.50 EMERGENCY SPILLWAY WIDTH = 20' BOTTOM OF BASIN ELEV. = 782.00 LEGEND NO.TITLE KEY SYMBOL 3.02 TEMPORARY STONE CONSTRUCTION ENTRANCE CE - LIMITS OF DISTURBANCE 3.05 SUPER SILT FENCE SF SF NOTES: 1.LIMITS OF DISTURBANCE SHALL BE AS INDICATED. THE ESTIMATED DISTURBED AREA FOR THIS PROJECT IS 3.59 ACRES. 2.THE EXISTING ENTRANCE CAN BE UTILIZED FOR A TEMPORARY CONSTRUCTION ENTRANCE WHILE IMPROVEMENTS IN THE VICINITY OF THE NEW ENTRANCE ARE COMPLETED, AT WHICH TIME THE CONSTRUCTION ENTRANCE WILL BE AS SHOWN.MATCHLINE -- THIS SHEET MATCHLINE -- THIS SHEET 1 2 SWMB-A 3.07 STORM DRAIN INLET PROTECTION IP 1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS XXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XX XXXXXXXXXXXXXXXXXXXXXXXXXXXXX CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYSITE PLANJOB NO.: 22-01 C-06C-06.DWGDDD1" = 20'DDDDESCRIPTION06-28-20221 inch = ft. ( IN FEET ) GRAPHIC SCALE 20 02-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VAPROPOSED 1092 SQ. FT. OFFICE (1-STORY) HEIGHT = 12' 5' CONC. S/W (TURN-DOWN) SLIDING GATE W/ KNOX BOX PROPOSED 42,000 SQ. FT. (105' x 400') STORAGE FACILITY (BUILDING #1) HEIGHT = 12' (+/-) ADA ACCESS PROPOSED 16,000 SQ. FT. (100' x 160') STORAGE FACILITY (BUILDING #3) HEIGHT = 12' (+/-) PROPOSED 3,200 SQ. FT. (40' x 80') STORAGE FACILITY (BUILDING #2) HEIGHT = 10' (+/-) 3 3 4 6' HIGH CHAIN-LINK SECURITY FENCING PEDESTAL CARD READER W/ (2) BOLLARDS PEDESTAL CARD READER W/ (2) BOLLARDS 5' 8' (2) HANDICAP SIGNS 25' 32' 30' 30' STANDARD-DUTY ASPHALT PAVEMENT (SEE DETAIL, SHEET C-26) CG-6RCG-6RCG-6RCG-2 CG-2 CG-6 CG-7 E.P.E.P.CG-12 FREESTANDING SIGN STOP SIGN 24" WHITE STOP BAR (TYPE 'B' PAINT) CONC. BOLLARD CONC. BOLLARD CONC. BOLLARD CG-6RCG-6R32' SHADING DEPICTS PROPOSED HANDICAP ACCESSIBLE UNITS (22) 5' CONC. S/W CG-12 2 CG-625'CG-2CG-218' 24' 10' 8' HC SIGN CG-12 5' CONC. S/WCG-6CG-7 R25' R30' R48' CONC. BOLLARD (2) CONC. BOLLARDS CG-6R3 TRANSITION FROM CG-6R TO CG-6 TRANSITION FROM CG-6R TO CG-6 CG-63-HOUR FIRE RATED PARTITION CG-6R CG-6R1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22 PROPOSED CG-11 ENTRANCE (COMMERCIAL) PROPOSED TURN ARROW (VDOT PM-10) CROSSWALK (VDOT PM-3) DOTTED EXTENSION LINE (VDOT PM-3) (200' LENGTH) 8" SOLID WHITE LINE (VDOT PM-3) 16.4' 14.0' 100' 32' R25' EX. R/W R25' 14.0'14.0' HEAVY-DUTY ASPHALT PAVEMENT WITHIN HATCHED AREA (SEE TYPICAL SECTION, SHEET C-26) STANDARD-DUTY ASPHALT PAVEMENT HATCHING DEPICTS POTENTIAL AREA OF MILLING & OVERLAY OF ADJACENT TRAVEL LANE PER DIRECTION OF VDOT INSPECTOR 302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS6' x 6' HVAC CONC. PAD 6' x 6' HVAC CONC. PAD 6' x 20' HVAC CONC. PAD 6' x 6' HVAC CONC. PAD XXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X W W W W W W W W W W W W W W W W W W W W W W X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X WWWWWWWWWWWWWWWWWXXXXXXXXXXXXXXXXXXW W W W W W W W WWWWXXXW W WWWWW W W W W W W W XXXWWXXXXXX CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYUTILITY PLANJOB NO.: 22-01 C-07C-07.DWGDDD1" = 20'DDDDESCRIPTION06-28-20221 inch = ft. ( IN FEET ) GRAPHIC SCALE 20 02-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VAPROPOSED 1092 SQ. FT. OFFICE (1-STORY) PROPOSED 42,000 SQ. FT. (105' x 400') STORAGE FACILITY (BUILDING #1) PROPOSED 16,000 SQ. FT. (100' x 160') STORAGE FACILITY (BUILDING #3) PROPOSED 3,200 SQ. FT. (40' x 80') STORAGE FACILITY (BUILDING #2) FDC W/ (2) BOLLARDS F.H. ASSEMBLY (DEDICATED TO FDC) 150.34LF - 4" PVC SDR 35/26 SAN. SEW. @ 2.82% 12" DIP CL52 W/L 'A' (FW) 8" DIP CL52 W/L 'C' (FW) 6" DIP CL52 W/L 'E' (PRIVATE) 5/8" WATER METER W/ TRAFFIC RATED METER BOX, LID & (2) BOLLARDS (CONTRACTOR TO COORDINATE METER LOCATION WITH FW INSPECTOR) 22.5° BEND 8" x 6" REDUCER F.H. ASSEMBLY (CONTRACTOR SHALL COORDINATE G.V. PLACEMENT TO AVOID CURB & GUTTER WITH THE FW INSPECTOR) 8" x 8" x 6" TEE 8" x 8" x 8" TEE (3) G.V. 45° BEND 12" x 12" x 8" TEE (2) 12" G.V. (1) 8" G.V. CORP. STOP 36LF - 3" PVC SDR 21 CASING 1" CTS PET W/L 'F' (200 PSI, PRIVATE) C.O. @ 45° BEND (FW LINE ENDS 1' PAST G.V., BECOMES PRIVATE TO BLDG.) F.H. ASSEMBLY W/ (2) BOLLARDS (TYP.) 6" DIP CL52 W/L 'D' (FW) 6" ROOF DRAIN (TYP. OF 20) 6" DIP CL52 W/L 'C' (FW) 45° BEND 8" DIP CL52 W/L 'B' (FW) 45° BEND 45° BEND 6" x 6" x 6" TEE (2) 6" G.V. MATCHLINE -- THIS SHEET MATCHLINE -- THIS SHEET REMOVE EX. 12" W/L IN CLOUDED AREA (SEE CONNECTION NOTE #4) UTILITY ROOM UTILITY ROOM REPLACE EX. F.H. & LINE IN CLOUDED AREA (SEE NOTES ABOVE) PROPOSED 20' EASEMENT (FW) PROPOSED 20' EASEMENT (FW) FREDERICK WATER MAIN CONNECTION NOTES: 1.ALL WORK SHALL BE PERFORMED PER FREDERICK WATER INSPECTOR'S REQUIREMENTS. 2.RESTRAINED JOINTS REQUIRED FOR ANY FREDERICK WATER WATERLINES INSTALLED IN FILL MATERIAL. RESTRAINED JOINTS FOR PIPING SHALL EXTEND A MINIMUM OF 20' INTO ORIGINAL GROUND. 3.STAINLESS STEEL HP PROTECTUS 3 METER AND DOUBLE DETECTOR ARE REQUIRED AND TO BE LOCATED IN INTERIOR UTILITY ROOM NEXT TO FIRE DEPARTMENT CONNECTION. PIPING THROUGH FIRE METER AND DOUBLE CHECK DETECTOR SHALL BE AS REQUIRED BY FREDERICK WATER INSPECTOR. 4.CONTRACTOR SHALL: A.TEST PIT THE EXISTING MAIN PER FREDERICK WATER INSPECTOR'S REQUIREMENTS. B.EXERCISE EXTREME CAUTION WHILE TRAVELING AND WORKING OVER THE EXISTING ASBESTOS-CEMENT WATER MAIN AND SANITARY MAIN. C.INSTALL JOINT RESTRAINTS ON EXISTING MAIN IF REQUIRED BY FREDERICK WATER INSPECTOR PRIOR TO SHUT-DOWN. D.INSTALL A MINIMUM OF (1) FULL PIPE JOINT OF DIP CL52 WATERLINE BETWEEN THE PROPOSED BENDS AND REMAINING ASBESTOS-CEMENT PIPE PER FREDERICK WATER INSPECTOR REQUIREMENTS. E.PREPARE WORK AS FAR IN ADVANCE AS POSSIBLE TO MINIMIZE SHUT DOWN TIME. F.HAVE SUFFICIENT RESOURCES ON-SITE TO ACCOMPLISH TASKS PER FREDERICK WATER INSPECTOR'S REQUIREMENTS. G.PREPARE A WATER SHUT-DOWN PLAN SATISFACTORY TO THE FREDERICK WATER INSPECTOR. FIREWATCH, NIGHT TIME WORK, ETC. MAYBE REQUIRED. H.SCHEDULE SHUTDOWN WITH THE FREDERICK WATER INSPECTOR, FREDERICK COUNTY FIRE MARSHALL, AND ALL AFFECTED CUSTOMERS AT LEAST (7) DAYS IN ADVANCE, AND MAKE PREPARATIONS AS REQUIRED BY ALL PARTIES. I.REMOVE AND DISPOSE OF ASBESTOS-CEMENT WATER MAIN REMOVED FROM SERVICE PER ALL REGULATORY AGENCY REQUIREMENTS. 5.PLEASE NOTE THAT FREDERICK WATER MAY REQUIRE ALL EXISTING ASBESTOS-CEMENT W/L LOCATED UNDER NEW CURB, GUTTER, AND SIDEWALK TO BE REPLACED. 6.CONTRACTOR SHALL ADJUST EXISTING FREDERICK WATER UTILITIES PER FREDERICK WATER INSPECTOR REQUIREMENTS. HYDRANT REPLACEMENT NOTES: 1.CONTRACTOR SHALL CONFIRM THAT EX. GATE VALVE IS RESTRAINED TO TEE, OR PROVIDE RESTRAINT. 2.CONTRACTOR SHALL REMOVE EX. 6" PIPE AND FIRE HYDRANT, AND PROVIDE TO FREDERICK WATER INSPECTOR. 3.CONTRACTOR TO INSTALL NEW TEE AND DIP CL52 PIPE FROM EXISTING GATE VALVE, AND INSTALL NEW FIRE HYDRANT ASSEMBLY IN SIMILAR LOCATION TO EXISTING HYDRANT. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1617 18 19 20 21 22 PROPOSED 20' EASEMENT (FW) 6" ROOF DRAIN W/ SPLASH BLOCK (TYP. OF 4) SWMB-A 6" ROOF DRAIN W/ SPLASH BLOCK (TYP. OF 11) 6" ROOF DRAIN W/ SPLASH BLOCK (TYP. OF 20) 3-HOUR FIRE RATED PARTITION 1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22JACK & BORE FOR PROPOSED STORM SEWER ROADWAY CROSSING (T.B.R.) C.O. @ 45° BEND RAISE TOP TO 790.50 CORE NEW INV. IN @ 779.20 (4") (GROUT) NOTE: ALL WORK @ M/H PER FW INSPECTOR REQUIREMENTS HATCHED AREA REPRESENTS PROPOSED 20' FREDERICK WATER ESM'T 20'302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS20LF - 16" SCH. 40 PVC CASING 30LF - 12" SCH. 40 PVC CASING EX. / PROP. SAN. SYSTEM PRIVATE BEYOND R/W XXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X W W W W W W W W W W W W W W W W W W W W W W X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X WWWWWWWWWWWWWWWWWXXXXXXXXXXXXXXXXXXW W W W W W W W WWWWXXXW W WWWWW W W W W W W W XXXWWXXXXXX794 794 794 794 796 798 794794794 798796794 794794 794 794 794 794794 794794784 784 788 788786788 794 794 792 790 788 790 792 794 790 790 790790794792794794CIP CIP IP IP IP IP IP IP IP IP IPIP IP IP OPSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SFSFSFS F SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SF SF SF SF SF SFSFSFSFSF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF OP IP IP IP IP IP IP RR RR CIP CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYFINAL E&SC PLANJOB NO.: 22-01 C-08C-08.DWGDDD1" = 20'DDDDESCRIPTION06-28-20221 inch = ft. ( IN FEET ) GRAPHIC SCALE 20 02-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VAPROPOSED 1200 SQ. FT. OFFICE (1-STORY) F.F. = 789.00 PROPOSED 42,000 SQ. FT. (105' x 400') STORAGE FACILITY (BUILDING #1) F.F. = 794.50 PROPOSED 16,000 SQ. FT. (100' x 160') STORAGE FACILITY (BUILDING #3) F.F. = 794.60 PROPOSED 3,200 SQ. FT. (40' x 80') STORAGE FACILITY (BUILDING #2) F.F. = 794.75 MATCHLINE -- THIS SHEET MATCHLINE -- THIS SHEET NOTE: 1.LIMITS OF DISTURBANCE SHALL BE AS INDICATED. THE ESTIMATED DISTURBED AREA FOR THIS PROJECT IS 3.59 ACRES. LEGEND NO.TITLE KEY SYMBOL - LIMITS OF DISTURBANCE 3.05 SUPER SILT FENCE SF SF 3.07 STORM DRAIN INLET PROTECTION IPSTD. ES-2 INV.=783.85 INV.=779.25 STD. ES-2 INV.=782.50 STONE GABION (3' WIDE) TOP = 787.50 BOTTOM = 783.50 SEDIMENT FOREBAY REQ'D VOL. = 2659 CU. FT.) DESIGN VOL. = 2692 CU. FT.) 20' WIDE EMERGENCY SPILLWAY (ELEV.=788.50) W/ VDOT CLASS A1 RIP-RAP SCC #1 SCC #2 SCC #3 1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22 SWMB 'A'302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS XXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X W W W W W W W W W W W W W W W W W W W W W W X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X WWWWWWWWWWWWWWWWWXXXXXXXXXXXXXXXXXXW W W W W W W W WWWWXXXW W WWWWW W W W W W W W XXXWWXXXXXX794 794 794 794 796 798 794794794 798796794 794794 794 794 794 794794 794794784 784 788 788786788 794 794 792 790 788 790 792 794 790 790 790790794792794794CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYGRADING PLANJOB NO.: 22-01 C-09C-09.DWGDDD1" = 20'DDDDESCRIPTION06-28-20221 inch = ft. ( IN FEET ) GRAPHIC SCALE 20 02-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VAPROPOSED 1200 SQ. FT. OFFICE (1-STORY) F.F. = 789.00 PROPOSED 42,000 SQ. FT. (105' x 400') STORAGE FACILITY (BUILDING #1) F.F. = 794.50 PROPOSED 16,000 SQ. FT. (100' x 160') STORAGE FACILITY (BUILDING #3) F.F. = 794.60 PROPOSED 3,200 SQ. FT. (40' x 80') STORAGE FACILITY (BUILDING #2) F.F. = 794.75 793.00 (L.P.) 793.50 (H.P.) 793.00 (L.P.) 793.00 (L.P.) 793.50 (H.P.) 793.50 (L.P.) 794.80 (T.C.) 794.30 (E.P.) 794.75 (T.C.) 794.25 (E.P.) 794.97 (T.C.) 794.30 (E.P.) 794.97 (T.C.) 794.30 (E.P.) 794.67 (T.C.) 794.00 (E.P.) 794.00 (H.P.) 794.92 (T.C.) 794.25 (E.P.) 794.47 (T.C.) 793.80 (E.P.)793.50 (L.P.) 794.67 (T.C.) 794.00 (E.P.) 794.87 (T.C.) 794.20 (E.P.) 794.00 (H.P.) 793.50 (L.P.) 794.00 (H.P.)794.00 (H.P.) 794.00 (H.P.) 793.50 (L.P.) 793.50 (L.P.)793.50 (L.P.) 793.65 (L.P.) 794.35 795.00 (T.C.) 794.50 (E.P.) 795.14 (T.C.) 794.47 (E.P.) 794.75 (T.C.) 794.25 (E.P.) 794.55 (T.C.) 794.05 (E.P.) 794.75 (T.C.) 794.25 (E.P.) 794.55 (T.C.) 794.05 (E.P.) 787.63 (T.C.) 787.13 (E.P.) 787.92 793.88 (T.C.) 793.55 (E.P.) ABBREVIATIONS: H.P. = HIGH POINT L.P. = LOW POINT T.C. = TOP OF CURB T.S. = TOP OF SIDEWALK E.P. = EDGE OF PAVEMENT F.F. = FINISHED FLOOR 794.87 (T.C.) 794.20 (E.P.) 794.77 (T.C.) 794.10 (E.P.) 795.36 (T.C.) 794.69 (E.P.) 795.28 (T.C.) 794.61 (E.P.) 794.82 (T.C.) 794.15 (E.P.) 794.25 794.45 794.37 794.77 MATCHLINE -- THIS SHEET MATCHLINE -- THIS SHEET MATCHLINE -- THIS SHEET 793.00 (L.P.)793.00 (L.P.) 793.50 (H.P.) 793.00 (L.P.) 793.50 (H.P.) 794.55 794.55 794.35 794.55 794.55 794.35 794.35 794.55 794.55 794.35 794.35 794.55 794.55 794.35 794.35 794.87 (T.C.) 794.25 (E.P.) 794.67 (T.C.) 794.00 (E.P.) 793.88 (T.C.) 793.55 (E.P.) 793.58 (T.C.) 793.25 (E.P.) 793.88 (T.C.) 793.55 (E.P.) 793.58 (T.C.) 793.25 (E.P.) 793.78 (T.C.) 793.45 (E.P.) 794.72 (T.C.) 794.05 (E.P.)793.98 (T.C.) 793.65 (E.P.) 795.32 (T.C.) 794.65 (E.P.) 795.12 (T.C.) 794.45 (E.P.) 795.07 (T.C.) 794.40 (E.P.) 794.92 (T.C.) 794.25 (E.P.) 794.75 (T.C.) 794.25 (E.P.) 794.45 794.25 794.45794.25 794.25 794.45 794.25 794.25 794.25 794.05 794.50 794.57 (T.C.) 793.90 (E.P.) 794.87 (T.C.) 794.20 (E.P.) 794.15 794.45 794.25 794.25794.45 794.25 794.45 794.69 794.57 (T.C.) 793.90 (E.P.) 794.55 (T.C.) 794.05 (E.P.) 794.80 (T.C.) 794.30 (E.P.) 790.96 788.46 788.86 788.54788.54 790.96 790.96 788.75 787.81 (T.C.) 787.48 (E.P.) 788.42 (T.C.) 787.92 (E.P.) 788.78 (T.S.) 788.28 (E.P.) 788.83 (T.S.) 787.92 788.78 (T.S.) 788.28 (E.P.) 788.83 (T.S.) 788.28 786.76 (T.C.) 786.60 (E.P.) 787.92 (T.C.) 786.76 (E.P.) 785.76 (T.C.) 785.60 (E.P.) 785.31 (T.C.) 785.15 (E.P.) 784.80 (T.C.) 784.64 (E.P.) 786.69 (T.C.) 786.53 (E.P.) 787.08 (T.C.) 786.92 (E.P.) 787.81 (T.C.) 787.65 (E.P.) 788.90 (T.C.) 788.74 (E.P.) 789.07 (T.C.) 788.91 (E.P.) 789.64 (T.C.) 789.48 (E.P.) 785.07 (T.C.) 784.74 (E.P.) 786.06 785.10 (T.S.) 785.47 (T.S.) 785.69 (T.S.)785.85 (T.S.) 785.88 (T.S.)789.75 (T.S.) 786.76 (T.S.) 789.15 (T.S.)788.06 (T.S.)787.33 (T.S.) INV.=783.85 INV.=779.25 INV.=782.50 795.02 (T.C.) 794.35 (E.P.) 795.17 (T.C.) 794.50 (E.P.) 794.15 794.13 (T.C.) 793.80 (E.P.) 794.58 (T.C.) 794.25 (E.P.) 794.15 794.58 (T.C.) 794.25 (E.P.) 784.02 (EX. T.C.) 783.86 (EX. E.P.) 784.67 (EX. T.C.) 784.51 (EX. E.P.) 790.50 1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS XXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X W W W W W W W W W W W W W W W W W W W W W W X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X WWWWWWWWWWWWWWWWWXXXXXXXXXXXXXXXXXXW W W W W W W W WWWWXXXW W WWWWW W W W W W W W XXXWWXXXXXX794 794 794 794 796 798 794794794 798796794 794794 794 794 794 794794 794794784 784 788 788786788 794 794 792 790 788 790 792 794 790 790 790790794792794794CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYLANDSCAPE PLANJOB NO.: 22-01 C-10C-10.DWGDDD1" = 20'DDDDESCRIPTION06-28-20221 inch = ft. ( IN FEET ) GRAPHIC SCALE 20 02-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VANOTES: 1.OWNER OF PROPERTY SHALL MAINTAIN REQUIRED LANDSCAPING IN GOOD CONDITION. 2.SPECIFIED PLANT SPECIES MAY BE SUBJECT TO SUBSTITUTION WITH THE REQUIREMENT THAT NEWLY SELECTED SPECIES PROVIDE THE SAME VISUAL EFFECT. 3.PRIOR TO PLANT SPECIES SUBSTITUTION WRITTEN APPROVAL MUST BE GRANTED BY THE FREDERICK COUNTY PLANNING DEPARTMENT. 4.ALL PLANTING SHALL CONFORM WITH 165-203.01B OF THE FREDERICK COUNTY ZONING ORDINANCE (PLANT SELECTION, PLANTING PROCEDURE, AND MAINTENANCE). 5.NO TREES OR SHRUBS SHALL BE PLACED WITHIN FREDERICK WATER EASEMENT. 6.EXISTING MATURE VEGETATION SATISFYING THE FULL SCREEN REQUIREMENTS FOR THE BUFFER ALONG THE NORTHEAST PROPERTY LINE WILL BE MAINTAINED, AND IF REMOVED, WILL BE REPLACED WITH PLANTINGS SATISFYING THE ZONING ORDINANCE REQUIREMENTS FOR THE REQUIRED BUFFER.CHINESE HOLLY KOUSA DOGWOOD LEGEND: QUANT. PLANT SCHEDULE COMMON NAMEBOTANICAL NAME REMARKS 16 Kousa DogwoodCornus kousa 2" Caliper22 Chinese HollyIlex cornuta 36" Minimum Height35 TYPE Interior & Perimeter Tree Parking Screen Shrub WHITE PINE White PinePinus strobus 4' Minimum Height Screening Evergreen EXISTING TREES / VEGETATION TO SUPPLEMENT FENCING W/ OPAQUE SCREEN FOR FULL ZONING DISTRICT BUFFER PERIMETER LANDSCAPING: REQUIRED: ·1 TREE FOR EVERY 10,000 SQ. FT. OF IMPERVIOUS AREA FOR SELF-SERVICE STORAGE FACILITY. ·TOTAL IMPERVIOUS AREA = 40,510 SQ. FT. ·(40,510 / 10,000) = 4 TREES PROVIDED: ·4 TREES AROUND PERIMETER OF IMPERVIOUS AREAS PARKING LOT SCREEN: REQUIRED: ·A 3 FT. HIGH SCREEN TO PREVENT HEADLIGHTS FROM SHINING ONTO ADJOINING PROPERTY OR RIGHT OF WAY ·MAXIMUM 4 FT. SPACING OF SHRUBS PROVIDED: ·19 SHRUBS PLANTED AT HEIGHT OF 3 FT. AND SPACED AT 4 FT. ON CENTER FOR VEHICLE PARKING AREA INTERIOR LANDSCAPING: REQUIRED: ·MINIMUM OF 5% OF INTERIOR PARKING LOTS SHALL BE LANDSCAPED WITH SHADE TREES. ·TOTAL INTERIOR PARKING AREA = 3816 SQ. FT. ·(0.05) * 3816 = 191 SQ. FT. ·1 SHADE TREE FOR EVERY 10 PARKING SPACES ·20 SPACES / 10 = 2 REQUIRED TREES PROVIDED: ·1080 SQ. FT. OF INTERIOR LANDSCAPING ·2 INTERIOR SHADE TREES SELF-STORAGE SCREEN: REQUIRED: ·DOUBLE ROW OF STAGGERED EVERGREEN TREES PLANTED AT 12' CENTERS FOR SCREENING OF OVERHEAD DOORS AND STORAGE IN B2 DISTRICT ·A SOLID BUILDING WALL, FREE OF WINDOWS OR DOORS, IS NOT REQUIRED TO BE SCREENED PER 165-204.18(F)(4)(A) ·PLAN DOES NOT INCLUDE ANY EXTERIOR OVERHEAD DOORS, THEREFORE ADDITIONAL SCREENING NOT REQUIRED 6' HIGH CHAIN-LINK SECURITY FENCING WITH OPAQUE GREEN SLATS (SLATS ALONG REAR AND SIDE PROPERTY BOUNDARIES) FOR CATEGORY 'B' FULL ZONING DISTRICT BUFFER 1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22 END OPAQUE GREEN SLAT SCREENING ON SECURITY FENCE BEGIN OPAQUE GREEN SLAT SCREENING ON SECURITY FENCE REMOVE EXISTING VEGETATION AS NECESSARY FOR PROPOSED PLANTINGS ASSOCIATED WITH CATEGORY 'B' FULL ZONING DISTRICT BUFFER CATEGORY 'B' FULL ZONING DISTRICT BUFFER (SEE DETAIL, SHEET C-25) PLANTINGS NOT PROVIDED WITHIN FREDERICK WATER EASEMENT HEADLIGHT SCREEN NOT PROVIDED DUE TO FULL SCREEN ZONING DISTRICT BUFFER BUFFER/SCREENING LANDSCAPING: CATEGORY 'B' FULL SCREEN: ·REQUIRED PLANTINGS OF 3 FOR EVERY 10 FT. W/ EQUAL QUANTITIES OF DECIDUOUS, EVERGREEN, AND SHRUBS. ·LENGTH OF BUFFER = 160 FT. (EXCLUSIVE OF FREDERICK WATER EASEMENTS) ·(160 / 10) * 3 = 48 PLANTINGS (16 EACH TYPE) ·48 PLANTINGS PROVIDED (16 EACH TYPE) TYPICAL CATEGORY 'B' FULL SCREEN DETAIL 302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS XXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X W W W W W W W W W W W W W W W W W W W W W W X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X WWWWWWWWWWWWWWWWWXXXXXXXXXXXXXXXXXXW W W W W W W W WWWWXXXW W WWWWW W W W W W W W XXXWWXXXXXX CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYLIFE SAFETY PLANJOB NO.: 22-01 C-11C-11.DWGDDD1" = 20'DDDDESCRIPTION06-28-20221 inch = ft. ( IN FEET ) GRAPHIC SCALE 20 02-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VAPROPOSED 1200 SQ. FT. OFFICE (1-STORY) HEIGHT = 12' SLIDING GATE W/ KNOX BOX PROPOSED 42,000 SQ. FT. (105' x 400') STORAGE FACILITY (BUILDING #1) HEIGHT = 12' (+/-) PROPOSED 16,000 SQ. FT. (100' x 160') STORAGE FACILITY (BUILDING #3) HEIGHT = 12' (+/-) 6' HIGH CHAIN-LINK SECURITY FENCING PEDESTAL CARD READER W/ (2) BOLLARDS PEDESTAL CARD READER W/ (2) BOLLARDS NOTES: 1.FIRE LANE SIGNAGE AND MARKINGS TO CONFORM TO THE FREDERICK COUNTY FIRE PREVENTION CODE APPENDIX D FIRE APPARATUS ACCESS ROADS D103.6 SIGNS, AND BE PLACED IN ACCORDANCE WITH THE FIRE MARSHAL'S OFFICE. EDGE OF PAVEMENT AT FIRE LANE SIGNS SHALL BE MARKED WITH A SOLID 6" WIDE YELLOW LINE TO DELINEATE EXTENTS OF FIRE LANE. 2.REFER TO TYPICAL FIRE LANE SIGN DETAILS, THIS SHEET. FDC W/ (2) BOLLARDS F.H. (DEDICATED TO FDC) F.H. F.H. UTILITY ROOM UTILITY ROOM FIRE LANE SIGN (TYPE 'D') (BLDG. MOUNTED) FIRE LANE (TYP.) FIRE LANE SIGN (TYPE 'D') FIRE LANE SIGN (TYPE 'C') FIRE LANE SIGN (TYPE 'A') FIRE LANE SIGN (TYPE 'D') FIRE LANE SIGN (TYPE 'C') FIRE LANE SIGN (TYPE 'A') FIRE LANE SIGN (TYPE 'C') FIRE LANE SIGN (TYPE 'D') FIRE LANE SIGN (TYPE 'A') FIRE LANE SIGN (TYPE 'C') FIRE LANE SIGN (TYPE 'C') FIRE LANE SIGN (TYPE 'A') FIRE LANE SIGN (TYPE 'A') FIRE LANE SIGN DETAILS 1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22 PROPOSED 3,200 SQ. FT. (40' x 80') STORAGE FACILITY (BUILDING #2) HEIGHT = 10' (+/-) 3-HOUR FIRE RATED PARTITION 302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS XXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXLuminaire Schedule Symbol Qty Label 3 PRV-C40-D-UNV-T2-BZ 2 PRV-C40-D-UNV-T3-BZ 57 AXCS3A 1 PRV-C40-D-UNV-T3-BZ 180 Calculation Summary Units Avg Max Min Fc 3.35 44.9 0.0 0.1 0.2 0.4 0.3 0.6 0.8 0.7 0.4 0.7 1.0 1.4 2.2 2.5 1.8 1.3 0.7 0.6 0.8 1.6 2.6 4.1 5.2 3.7 2.4 1.7 1.1 1.7 1.4 1.1 1.3 2.4 4.2 4.1 4.1 4.0 3.2 2.1 1.5 1.0 0.3 1.2 2.1 2.6 2.3 2.2 2.7 3.9 5.2 4.0 4.3 3.6 2.4 1.6 1.0 0.7 0.5 0.1 0.2 1.2 3.0 4.1 3.7 3.4 3.3 3.5 3.5 3.4 3.0 2.5 1.8 1.1 0.8 0.5 0.3 0.2 0.7 3.4 5.6 4.7 4.5 3.7 3.0 2.5 2.3 2.5 3.3 2.1 1.1 1.3 0.7 0.2 0.1 0.3 0.8 2.3 4.6 4.7 5.3 3.9 2.7 2.0 1.8 3.5 17.3 5.1 8.4 2.0 0.4 0.1 0.8 1.6 3.5 4.9 4.9 4.0 2.6 1.8 1.6 1.8 17.3 3.0 0.5 0.1 0.1 0.4 1.2 2.5 5.2 5.5 3.8 2.5 1.8 2.7 11.8 0.8 0.3 1.1 0.8 0.2 0.0 0.9 1.4 3.2 4.1 3.5 2.6 1.8 2.4 10.2 21.4 2.9 0.6 2.5 5.9 4.2 0.6 1.3 0.9 0.2 0.9 1.2 2.0 3.1 3.0 2.6 1.8 1.6 2.0 1.2 2.0 3.8 3.6 3.2 7.5 9.0 1.3 1.4 0.5 0.9 1.6 2.2 2.3 0.7 0.2 1.1 1.5 2.2 2.8 2.9 2.5 1.8 1.3 1.0 1.7 2.8 3.5 5.0 17.0 12.3 2.5 0.6 0.8 1.9 3.5 4.6 2.6 0.4 1.2 1.4 1.5 1.9 2.9 3.8 3.5 2.8 2.1 1.4 1.0 2.0 5.1 15.7 12.0 2.8 0.7 0.6 1.5 4.0 7.2 5.6 1.4 0.5 1.5 3.9 3.9 3.4 2.2 2.2 3.6 6.0 5.6 3.9 2.8 1.8 1.1 1.2 1.5 0.8 1.3 1.6 2.7 5.8 7.2 4.3 1.0 1.3 3.4 3.7 18.7 6.1 16.3 3.3 2.5 3.8 8.0 8.5 5.3 4.0 2.2 1.4 1.5 8.2 11.9 2.5 1.9 6.0 5.8 2.1 4.1 7.4 5.5 1.4 1.4 1.8 3.2 20.8 4.6 5.5 2.7 2.8 4.1 6.0 7.9 5.8 5.1 2.9 1.9 3.3 17.3 44.9 6.7 3.1 4.0 4.7 2.3 11.2 2.8 3.5 5.8 7.9 3.3 0.4 1.1 1.8 9.2 8.5 2.6 3.3 4.0 5.3 7.3 7.8 5.1 3.3 2.0 2.4 7.8 5.8 4.6 8.8 4.8 2.7 7.6 20.2 18.5 5.3 4.3 5.5 3.7 0.9 1.0 3.5 7.1 1.9 14.0 7.0 3.7 4.8 6.1 9.7 5.9 3.0 1.8 1.5 1.5 1.9 8.4 4.8 2.8 4.7 16.9 3.5 3.7 2.9 3.3 2.6 1.3 0.3 1.4 3.6 2.2 6.0 5.6 2.9 3.4 4.3 6.6 5.3 2.9 1.8 1.3 1.3 1.7 2.8 7.7 5.4 2.1 1.8 3.1 2.5 1.6 1.1 0.4 1.5 1.8 3.7 22.7 1.8 2.8 2.7 2.7 3.6 3.7 2.5 2.0 1.9 3.4 4.7 2.5 12.1 12.1 2.5 1.1 0.7 0.4 0.5 2.1 11.1 7.4 0.6 11.8 3.2 2.1 2.2 2.6 2.8 3.5 2.8 9.5 18.2 6.6 2.0 1.0 0.5 0.3 0.1 0.1 0.8 5.0 12.4 3.2 2.1 2.4 2.7 5.4 18.6 3.6 1.7 1.4 0.5 0.3 0.1 0.7 4.2 12.7 14.0 2.6 1.3 2.0 2.9 8.9 5.6 3.0 10.7 4.1 0.8 0.2 0.1 0.1 1.2 1.1 1.5 2.5 3.1 10.5 3.6 3.8 4.7 2.8 13.4 4.9 0.8 0.2 0.1 0.1 1.1 1.5 6.1 1.6 16.5 7.0 2.8 3.8 2.6 10.6 15.0 0.8 0.4 0.2 0.1 0.0 0.0 1.6 12.3 10.1 13.7 2.7 3.6 2.9 5.6 18.6 2.3 18.2 3.3 0.5 0.2 0.1 0.1 0.0 0.0 1.7 2.0 1.2 14.9 2.8 4.2 4.4 3.3 9.9 4.3 2.1 0.1 2.0 7.8 2.4 0.5 0.1 0.0 0.0 1.8 2.4 0.0 2.5 3.6 9.2 3.4 4.5 4.8 2.5 0.5 0.1 0.1 0.6 0.9 0.5 0.1 0.0 1.7 4.6 21.3 1.6 16.6 5.8 2.8 3.8 2.6 12.1 8.6 15.3 1.7 0.3 0.1 0.1 0.1 0.0 1.3 1.5 2.9 1.4 3.4 2.7 6.5 18.6 0.1 0.3 2.4 2.8 0.9 0.2 0.0 0.0 2.1 1.3 1.0 1.4 3.0 11.0 3.7 3.3 0.5 0.1 0.2 0.4 0.4 0.1 0.0 1.1 1.3 2.1 4.2 4.1 2.5 1.2 13.2 5.2 0.7 0.2 0.1 0.1 0.0 0.0 0.1 1.0 1.6 13.9 0.1 0.1 0.6 1.6 1.0 0.3 0.0 0.0 0.2 0.3 1.0 2.6 19.3 2.5 0.4 0.1 0.2 0.2 0.1 0.0 0.1 0.3 1.3 10.8 0.2 2.6 6.1 1.7 0.3 0.1 0.0 0.4 1.0 3.0 2.6 0.4 0.1 0.2 0.6 0.8 0.4 0.1 0.6 0.7 0.9 1.3 13.1 10.8 1.2 0.2 0.1 0.1 0.1 0.9 0.9 3.1 20.0 0.1 0.5 2.5 2.0 0.7 0.1 0.0 1.1 1.9 6.3 2.8 0.4 0.1 0.2 0.4 0.3 0.0 1.7 1.1 1.4 1.4 1.9 12.2 3.5 0.5 0.1 0.1 0.0 4.2 5.7 3.2 1.3 1.6 8.1 0.1 0.1 0.7 1.4 0.8 0.2 0.0 8.1 5.3 2.2 1.5 4.5 6.4 16.8 1.8 0.3 0.1 0.2 0.2 0.0 5.9 7.4 3.9 1.5 1.3 1.0 0.4 3.2 4.5 1.2 0.2 0.1 7.0 5.9 2.5 1.0 0.5 0.4 0.7 0.8 0.3 5.4 7.0 4.0 1.6 0.6 0.3 0.2 4.2 3.3 2.0 0.9 2.1 2.3 0.5 2.1 0.5 2.6 0.1 0.40.50.50.5 0.50.4 0.2 0.1 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 8.1 5.3 5.9 7.4 3.9 7.0 5.9 5.4 7.0 4.2 5.7 3.2 2.4 3.2 1.1 1.8 3.1 0.2 1.6 2.8 3.1 2.1 1.0 1.4 1.2 0.7 1.1 1.0 0.1 0.2 0.1 0.0 0.0 0.1 0.1 0.5 2.1 0.8 0.1 0.1 3.1 2.8 2.1 2.1 1.1 0.1 1.6 0.2 1.2 0.1 3.1 0.6 0.1 0.1 0.9 0.2 1.9 0.1 3.1 1.1 0.1 2.1 0.1 2.2 0.2 0.8 2.1 0.9 0.10.9 1.1 0.1 1.1 0.2 0.1 0.10.0 0.1 0.1 0.0 0.0 0.3 0.3 0.3 0.1 0.1 0.1 0.5 0.1 0.0 0.0 0.0 0.1 0.0 1.2 0.8 0.0 0.7 1.1 0.7 0.0 0.1 0.1 0.1 0.0 0.3 0.1 0.0 0.1 0.1 0.2 0.1 0.2 0.1 0.1 0.1 0.6 0.0 0.0 0.1 1.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYLIGHTING PLANJOB NO.: 22-01 C-12C-12.DWGDDD1" = 20'DDDDESCRIPTION06-28-20221 inch = ft. ( IN FEET ) GRAPHIC SCALE 20 02-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VAPROPOSED 1200 SQ. FT. OFFICE (1-STORY) PROPOSED 42,000 SQ. FT. (105' x 400') STORAGE FACILITY PROPOSED 16,000 SQ. FT. (100' x 160') STORAGE FACILITY PROPOSED 3,200 SQ. FT. (40' x 80') STORAGE FACILITY NOTES: 1.LIGHTING DESIGN BY CAPITAL ELECTRIC. 2.ALL PROPOSED LIGHTING SHALL BE DOWNCAST AND FULL CUTOFF FIXTURES AND CONFORM TO THE REQUIREMENTS IN THE FREDERICK COUNTY ZONING ORDINANCE SECTION 165-201.07. Mounting Ht. 20' 20' 10' 20'1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22 PRV-C40-D-UNV-T2-BZ PRV-C40-D-UNV-T2-BZ PRV-C40-D-UNV-T2-BZ PRV-C40-D-UNV-T3-BZ PRV-C40-D-UNV-T3-BZ PRV-C40-D-UNV-T3-BZ-180 AXCS3A (TYP.)302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS 775 780 785 790 795 800 775 780 785 790 795 800 -5+00 -4+00 -3+00 -2+00 -1+00 0+00 0+50 EYE (HT. = 3.5') (6' FROM STOP BAR, 17' FROM E.P.) OBJECT (HT. = 3.5') MIN. SIGHT DIS T A N C E = 5 3 0 ' ( 4 5 M P H ) (4-LANE MAJO R R O A D W / M E D I A N ) -5+30 -5+00 -4+00 -3+00 -2+00 -1+00 -0+00 XXXXXX X X XX794794798796794794794794784784788788786788794794792790788790792794790790790790794792794780 785 790 795 800 780 785 790 795 800 10+00 11+00 11+75STA. 10+00.00C/L EX. RTE. 522 (NBL)ELEV. = 786.56STA. 10+29.91EX. RIGHT-OF-WAYSTA. 11+50.00ELEV. = 792.61STA. 10+25.78LOW POINTELEV. = 786.06STA. 10+99.56GRADE BREAKELEV. = 788.86PROPOSED GRADE 5.00%STA. 10+11.78EX. EDGE LINEELEV. = 786.30STA. 10+12.85EX. E.P.STA. 10+33.28GRADE BREAKELEV. = 786.214.00% -2.00% 2.00% 10+00 11+00 11+50 W W W W W W W W W W W W W W XXXXXXXXX X XWWWWWWWWWWWWXXXXX7887 8 8 786788 794792790790 790 794 792 794 CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYENTRANCE PLANJOB NO.: 22-01 C-13C-13.DWGDDDDDDWINCHESTER SECURE STORAGEFREDERICK COUNTY, VADESCRIPTION06-28-202202-01-2023 AS SHOWNENTRANCE PLAN & PROFILE SCALE: 1" = 20' (HORIZ., 1" = 2' (VERT.) STOP SIGN PROPOSED CG-11 ENTRANCE (COMMERCIAL)525' TO INTX. W/RIVENDELL COURT24" WHITE STOP BAR W/ TYPE 'B' PAINT 250' TO INTX. W/DARLINGTON DR. (RTE. 1311)EX. R/WE.P. E.P. 32' SIGHT DISTANCE PLAN & PROFILE SCALE: 1" = 50' (HORIZ., 1" = 5' (VERT.) OBJECT (HT. = 3.5') EYE (HT. = 3.5') R25' R25' CG-12 5' CONC. S/W CG-12EX. R/W5' CONC. S/W CG-7 CG-7CG-7CG-7PROPOSED TURN ARROW (VDOT PM-10) CROSSWALK (VDOT PM-3) DOTTED EXTENSION LINE (VDOT PM-3) 8" SOLID WHITE LINE (VDOT PM-3)1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYPRE-DEVELOPED SWM PLANJOB NO.: 22-01 C-14C-14.DWGDDD1" = 30'DDDDESCRIPTION06-28-20221 inch = ft. ( IN FEET ) GRAPHIC SCALE 30 02-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VASHEET FLOW (45' @ 4.4%) A A A A B B B B C C C C SHEET FLOW (30' @ 3.3%) SHALLOW CONC. FLOW (165' @ 7.9%) SHALLOW CONC. FLOW (270' @ 7.0%) SHEET FLOW (40' @ 8.8%) SHEET FLOW (50' @ 15.0%) SHALLOW CONC. FLOW (375' @ 2.8%) SHALLOW CONC. FLOW (195' @ 1.0%) PRE-DEV. DA 'A' AREA = 3.66 AC. CN = 81 Tc = 6 MIN. Q1 = 5.43 CFS Q2 = 7.59 CFS Q10 = 13.98 CFS Q25 = 18.44 CFS Q100 = 26.33 CFS PRE-DEV. DA 'A' (OFFSITE) AREA = 1.87 AC. CN = 78 Tc = 5 MIN. Q1 = 2.29 CFS Q2 = 3.32 CFS Q10 = 6.40 CFS Q25 = 8.63 CFS Q100 = 12.61 CFS PRE-DEV. DA 'B' AREA = 0.49 AC. CN = 81 Tc = 6 MIN. Q1 = 0.73 CFS Q2 = 1.02 CFS Q10 = 1.87 CFS Q25 = 2.47 CFS Q100 = 3.53 CFS PRE-DEV. DA 'B' (OFFSITE) AREA = 0.42 AC. CN = 82 Tc = 5 MIN. Q1 = 0.66 CFS Q2 = 0.91 CFS Q10 = 1.66 CFS Q25 = 2.17 CFS Q100 = 3.08 CFS TOTAL PRE-DEV. @ ANALYSIS PT. 'B' Q1 = 1.39 CFS Q2 = 1.93 CFS Q10 = 3.53 CFS Q25 = 4.64 CFS Q100 = 6.61 CFS TOTAL PRE-DEV. @ ANALYSIS PT. 'A' Q1 = 7.72 CFS Q2 = 10.91 CFS Q10 = 20.38 CFS Q25 = 27.06 CFS Q100 = 38.94 CFS 1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS XXXXXXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXX 794 794 794 794 796 798 794794794 798796794 794794 794 794 794 794794 794794784 784 788 788786788 794 794 792 790 788 790 792 794 790 790 790790794792794794CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYPOST-DEVELOPED SWM PLANJOB NO.: 22-01 C-15C-15.DWGDDD1" = 30'DDDDESCRIPTION06-28-20221 inch = ft. ( IN FEET ) GRAPHIC SCALE 30 02-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VAA A B B C C SHEET FLOW (30' @ 3.3%) SHALLOW CONC. FLOW (270' @ 7.0%) SHEET FLOW (40' @ 15.0%) SHALLOW CONC. FLOW (140' @ 8.9%)POST-DEV. DA 'A' (ON-SITE TO SWMB) AREA = 3.50 AC. CN = 90 (1, 2, 10, 25, 100-YR) Tc = 5 MIN. Q1 = 8.42 CFS Q2 = 10.83 CFS Q10 = 17.39 CFS Q25 = 21.72 CFS Q100 = 29.21 CFS A B B A CHANNEL FLOW (710' @ 1.55%) SHEET FLOW (35' @ 5.7%) SHEET FLOW (70' @ 12.9%) SHALLOW CONC. FLOW (60' @ 2.5%) POST-DEV. DA 'A' (OFF-SITE TO SWMB) AREA = 2.20 AC. CN = 78 Tc = 5 MIN. Q1 = 2.69 CFS Q2 = 3.91 CFS Q10 = 7.53 CFS Q25 = 10.15 CFS Q100 = 14.84 CFS TOTAL POST-DEV. @ ANALYSIS PT. 'A' (INCLUDES DISCHARGE FROM SWMB 'A') Q1 = 3.03 CFS Q2 = 3.60 CFS Q10 = 5.14 CFS Q25 = 18.16 CFS Q100 = 28.95 CFS POST-DEV. DA 'B' (ON-SITE) AREA = 0.07 AC. CN = 74 (1, 2, 10, 25, 100-YR) Tc = 5 MIN. Q1 = 0.06 CFS Q2 = 0.10 CFS Q10 = 0.21 CFS Q25 = 0.28 CFS Q100 = 0.43 CFS POST-DEV. DA 'B' (OFF-SITE) AREA = 0.10 AC. CN = 81 Tc = 5 MIN. Q1 = 0.15 CFS Q2 = 0.21 CFS Q10 = 0.38 CFS Q25 = 0.50 CFS Q100 = 0.72 CFS C POST-DEV. DA 'A' (BYPASS SWMB) AREA = 0.58 AC. CN = 76 Tc = 5 MIN. Q1 = 0.62 CFS Q2 = 0.92 CFS Q10 = 1.84 CFS Q25 = 2.51 CFS Q100 = 3.73 CFS TOTAL POST-DEV. @ ANALYSIS PT. 'B' Q1 = 0.21 CFS Q2 = 0.31 CFS Q10 = 0.59 CFS Q25 = 0.79 CFS Q100 = 1.15 CFS 1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS XXXXXXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXX 794 794 794 794 796 798 794794794 798796794 794794 794 794 794 794794 794794784 784 788 788786788 794 794 792 790 788 790 792 794 790 790 790790794792794794CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYPOST-DEVELOPED SWM PLANJOB NO.: 22-01 C-16C-16.DWGDDD1" = 30'DDDDESCRIPTION06-28-20221 inch = ft. ( IN FEET ) GRAPHIC SCALE 30 02-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VASTR #8 STR #18 STR #19 STR #20 STR #21 STR #17 STR #16 STR #11STR #10 STR #13 STR #14 STR #15 A A A A A B B B B B C C C C C SHEET FLOW (35' @ 5.0%) SHALLOW CONC. FLOW (305' @ 4.3%) SHEET FLOW (35' @ 5.0%) SHALLOW CONC. FLOW (295' @ 6.2%) SHEET FLOW (40' @ 5.0%) SHALLOW CONC. FLOW (320' @ 6.9%) SHEET FLOW (25' @ 4.0%) SHALLOW CONC. FLOW (285' @ 8.1%) SHEET FLOW (40' @ 5.0%) SHALLOW CONC. FLOW (200' @ 9.8%) RD TO STR #10 RD TO STR #19 A B C SHEET FLOW (40' @ 5.0%) SHALLOW CONC. FLOW (295' @ 6.9%) STR #2 STR #4 STR #5 STR #6 STR #12 STR #22 RD TO STR #20 RD TO STR #21 RD TO STR #22 RD TO STR #17 RD TO STR #16 RD TO STR #11 RD TO STR #12 RD TO STR #13 SCC #1 SCC #2 SCC #3 EX. DI-3B ENTRANCE TO STONEWALL PLAZA 1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS 770 775 780 785 790 795 800 805 810 770 775 780 785 790 795 800 805 810 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00STA. 10+00.00 -- STR #7STD. ES-2INV. = 783.85 (24")STA. 10+40.00 -- STR #824" NYLOPLAST CURB INLETW/ 2' x 2' GRATE (L = 2')TOP = 793.75INV. IN = 784.25 (24")INV. OUT = 784.25 (24")STA. 11+31.44 -- STR #924" NYLOPLAST BASINTOP = 794.25 (SOLID)INV. IN = 784.71 (24")INV. OUT = 784.71 (24")STA. 11+61.44 -- STR #1030" NYLOPLAST BASINTOP = 793.50 (STD.)INV. IN = 784.86 (18")INV. IN = 784.86 (24")INV. OUT = 784.86 (24")STA. 12+46.44 -- STR #1118" NYLOPLAST BASINTOP = 793.50 (STD.)INV. IN = 790.00 (6")INV. IN = 785.29 (18")INV. OUT = 785.29 (24")STA. 13+50.86 -- STR #1218" NYLOPLAST BASINTOP = 793.50 (STD.)INV. IN = 785.81 (18")INV. OUT = 785.81 (18")STA. 14+70.86 -- STR #1318" NYLOPLAST BASINTOP = 793.50 (STD.)INV. IN = 786.41 (15")INV. OUT = 786.41 (18")STA. 15+91.44 -- STR #1418" NYLOPLAST BASINTOP = 793.50 (STD.)INV. IN = 788.82 (15")INV. OUT = 788.82 (15")STA. 16+78.44 -- STR #1515" NYLOPLAST BASINTOP = 793.65 (STD.)INV. IN = 789.26 (15")INV. OUT = 789.26 (15")STA. 18+27.09 -- STR #1718" NYLOPLAST BASINTOP = 793.00 (STD.)INV. OUT = 790.00 (12")STA. 14+10.866" W/L X-ING18" MIN. CLEAR (TYP.) 40.00 LF - 24" HDPE @ 1.00% 91.44 LF - 24" HDPE @ 0.50% 30.00 LF - 24" HDPE @ 0.50% HGL (10-YR) PROPOSED GRADE STA. 17+19.09 -- STR #1618" NYLOPLAST BASINTOP = 793.00 (STD.)INV. IN = 789.46 (12")INV. OUT = 789.46 (15")STA. 14+20.868" W/L X-ING85.00 LF - 24" HDPE @ 0.50% 104.42 LF - 18" HDPE @ 0.50% 120.00 LF - 18" HDPE @ 0.50% 120.58 LF - 15" HDPE @ 2.00% 87.00 LF - 15" HDPE @ 0.50% 40.65 LF - 15" HDPE @ 0.50% 108.00 LF - 12" HDPE @ 0.50%STA. 11+86.44 -- 6" R.D.STA. 12+06.44 -- 6" R.D.STA. 12+26.44 -- 6" R.D.STA. 12+66.44 -- 6" R.D.STA. 12+86.44 -- 6" R.D.STA. 13+06.44 -- 6" R.D.STA. 13+26.44 -- 6" R.D.STA. 13+46.44 -- 6" R.D.STA. 13+66.44 -- 6" R.D.STA. 13+86.44 -- 6" R.D.STA. 14+06.44 -- 6" R.D.STA. 14+26.44 -- 6" R.D.STA. 14+46.44 -- 6" R.D.STA. 14+66.44 -- 6" R.D.STA. 14+86.44 -- 6" R.D.STA. 15+06.44 -- 6" R.D.STA. 15+26.44 -- 6" R.D.STA. 15+46.44 -- 6" R.D.STA. 15+86.44 -- 6" R.D.STA. 15+66.44 -- 6" R.D.770 775 780 785 790 795 800 805 810 770 775 780 785 790 795 800 805 810 10+00 11+00 12+00 13+00 14+00 15+00 765 770 775 780 785 790 795 800 805 765 770 775 780 785 790 795 800 805 10+00 11+00 12+00 765 770 775 780 785 790 795 800 805 765 770 775 780 785 790 795 800 805 10+00 11+00 12+00 STA. 10+00.00 -- STR #3STD. ES-2INV. = 782.50 (15")STA. 10+40.00 -- STR #415" NYLOPLAST BASINTOP = 786.50 (STD.)INV. IN = 783.30 (15")INV. OUT = 783.30 (15")STA. 10+82.25 -- STR #518" NYLOPLAST BASINTOP = 786.50 (STD.)INV. IN = 783.72 (12")INV. OUT = 783.72 (15")STA. 11+23.50 -- STR #615" NYLOPLAST BASINTOP = 787.50 (STD.)INV. OUT = 784.55 (12")STA. 10+34.588" W/L X-ING18" MIN. CLEAR (TYP.) 40.00 LF - 15" HDPE @ 2.00% 42.25 LF - 15" HDPE @ 1.00% 41.25 LF - 12" HDPE @ 2.00% HGL (10-YR)STA. 10+97.00 -- STR #1818" NYLOPLAST BASINTOP = 793.50 (STD.)INV. IN = 788.26 (18")INV. OUT = 788.26 (18")PROPOSED GRADE STA. 10+86.6412" W/L X-ING18" MIN. CLEAR (TYP.)STA. 10+00.00 -- STR #1INV. = 779.45 (18")STA. 10+70.00 -- STR #2DI-3B (DIA. = 4', L = 10')TOP = 786.69 (HT. = 5.49')INV. IN = 781.40 (18")INV. OUT = 781.20 (18")STA. 11+30.00 -- SWMB 'A'SWM-1 (DIA. = 4')TOP = 787.00INV. OUT = 782.00 (18")70.00 LF - 18" STEEL PIPE @ 2.50% (JACK & BORE) 60.00 LF - 18" HDPE @ 1.00%STA. 10+62.888" SAN. X-INGINV. = 778.08STA. 10+00.00 -- STR #1030" NYLOPLAST BASINTOP = 793.50 (STD.)INV. IN = 784.86 (18")INV. IN = 784.86 (24")INV. OUT = 784.86 (24")STA. 11+27.81 -- STR #1924" NYLOPLAST BASINTOP = 793.00 (STD.)INV. IN = 788.57 (15")INV. OUT = 788.57 (18")STA. 12+25.81 -- STR #2018" NYLOPLAST BASINTOP = 793.00 (STD.)INV. IN = 789.06 (15")INV. OUT = 789.06 (15")STA. 13+05.81 -- STR #2118" NYLOPLAST BASINTOP = 793.00 (STD.)INV. IN = 789.46 (12")INV. OUT = 789.46 (15")STA. 13+96.06 -- STR #2218" NYLOPLAST BASINTOP = 793.00 (STD.)INV. OUT = 789.91 (12")97.00 LF - 18" HDPE @ 3.50% 30.81 LF - 18" HDPE @ 1.00% 98.00 LF - 15" HDPE @ 0.50% 80.00 LF - 15" HDPE @ 0.50% 90.25 LF - 12" HDPE @ 0.50% HGL (10-YR) PROPOSED GRADE HGL (10-YR) PROPOSED GRADE STA. 11+03.864" SAN. X-INGINV. = 779.74STA. 10+21.484" SAN. X-INGINV. = 780.75CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYSTORM SEWER PROFILESJOB NO.: 22-01 C-17C-17.DWGDDDDDDDESCRIPTION06-28-202202-01-2023 AS SHOWNSTR #1 - SWMB 'A'STR #10 - STR #22 STR #7 - STR #17 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VASTR #3 - STR #6 1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS 770 775 780 785 790 795 800 805 810 770 775 780 785 790 795 800 805 810 10+00 11+00 12+00 13+00 775 780 785 790 795 800 805 810 815 775 780 785 790 795 800 805 810 815 10+00 11+00 11+50 775 780 785 790 795 800 805 810 815 775 780 785 790 795 800 805 810 815 10+00 11+00 12+00 13+00STA. 10+00.0012" x 12" x 8" TEE(2) 12" G.V.(1) 8" G.V.STA. 10+91.54CORP. STOPSTA. 11+70.338" x 8" x 6" TEEF.H. ASSEMBLY (5' LT.)STA. 12+05.33BLDG. CONN.STA. 10+00.006" x 6" x 6" TEE(2) 6" G.V.PROPOSED GRADE 8" DIP CL 52 W/L (FW) PRIVATEFW 48" MIN. COVER 48" MIN. COVER 48" MIN. COVER PROPOSED GRADEPROPOSED GRADE 6" DIP CL 52 W/L (FW) 8" DIP CL 52 W/L (FW) 6" DIP CL 52 W/L (FW) 765 770 775 780 785 790 795 800 805 765 770 775 780 785 790 795 800 805 10+00 11+00 11+75STA. 10+00.0045° BENDSTA. 10+20.4545° BEND18" MIN. CLEAR (TYP.)STA. 10+21.9718" STM X-INGINV. = 781.55STA. 10+52.5212" x 12" x 8" TEE(2) 12" G.V.(1) 8" G.V.STA. 11+02.4545° BENDSTA. 11+22.8845° BEND18" MIN. CLEAR (TYP.)STA. 11+93.3318" STM X-INGINV. = 786.16STA. 11+83.338" x 8" x 8" TEE(3) 8" G.V.END OF FW LINE 1' PAST G.V.STA. 10+05.0045° BENDSTA. 10+08.4045° BENDSTA. 10+66.29F.H. ASSEMBLY (IN-LINE)STA. 10+00.008" x 8" x 8" TEE(3) 8" G.V.STA. 12+52.01F.H. ASSEMBLY (IN-LINE)STA. 12+18.0422.5° BEND8" x 6" REDUCER18" MIN. CLEAR (TYP.) 18" MIN. CLEAR (TYP.)STA. 10+20.3915" STM X-INGINV. = 783.19STA. 10+20.006" W/L X-INGW/ 16" CASING12" DIP CL 52 W/L (FW) PROPOSED GRADE 48" MIN. COVER STA. 10+37.544" SAN. X-INGW/ 12" CASINGINV. = 781.23STA. 10+05.0022.5° VERT. BENDSTA. 10+14.6622.5° VERT. BEND18" MIN. CLEAR (TYP.)STA. 10+08.0011.25° VERT. BEND10+00 11+00 12+0012+05 X XXXXXX X XXXXXXXXXXXXXXXXXXXX X 794794794796794794794794794794794794794 79478478478878 8 786788 794792790788790792794790790790 790 794 792 794794 10+0010+66X XXXXXXX79479479479479879679410+00 11+00 12+00 12+52 XXXXXXXXXXXXXXXXXXXXXXX X X X79479479479479479479479479479479479478478478878878678879479279078879079279479079079079079479279479410+0011+00 11+23XXXXX794 794794 794 788 788786788794 792 790 790790794792794CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYWATERLINE PLAN & PROFILEJOB NO.: 22-01 C-18C-18.DWGDDDDDDDESCRIPTION06-28-2022AS SHOWNWATERLINE 'A' (FW) 02-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VAWATERLINE 'B' (FW) W W W W W W W W W W W W W W W W W W WATERLINE 'D' (FW)WWWWWWWWWWWWWWWWCORP. STOP 8" x 8" x 8" TEE (3) 8" G.V. (END OF FW LINE 1' PAST G.V.) 8" DIP CL52 W/L 'B' (FW) STA. 12+05.33 BLDG. CONN. F.H. (DEDICATED TO FDC) FDC PROP. 20' ESM'T (FW) WATERLINE 'C' (FW) STA. 10+00.00 45° BEND WW W W WWWWWWWWWW W W W W 12" DIP CL52 W/L 'A' (FW) PROP. 20' ESM'T (FW) W WWW 45° BEND STA. 11+22.88 12" x 12" x 8" TEE (2) 12" G.V. (1) 8" G.V.WWWWWSTA. 10+00.00 12" x 12" x 8" TEE (2) 12" G.V. (1) 8" G.V. 8" x 8" x 6" TEE (1) 6" G.V.WWWWWWWWWW W W WW W W W STA. 10+00.00 8" x 8" x 8" TEE (3) 8" G.V. 22.5° BEND 8" x 6" REDUCER STA. 12+52.01 F.H. ASSEMBLY 8" DIP CL52 W/L 'C' (FW) 6" DIP CL52 W/L 'C' (FW)PROP. 20' ESM'T (FW) STA. 10+00.00 6" x 6" x 6" TEE (2) 6" G.V. STA. 10+66.29 F.H. ASSEMBLY 45° BEND REPLACE EX. F.H. PROP. 20' ESM'T (FW) HYDRANT REPLACEMENT NOTES: 1.CONTRACTOR SHALL CONFIRM THAT EX. GATE VALVE IS RESTRAINED TO TEE, OR PROVIDE RESTRAINT. 2.CONTRACTOR SHALL REMOVE EX. 6" PIPE AND FIRE HYDRANT, AND PROVIDE TO FREDERICK WATER INSPECTOR. 3.CONTRACTOR TO INSTALL NEW TEE AND DIP CL52 PIPE FROM EXISTING GATE VALVE, AND INSTALL NEW FIRE HYDRANT IN SIMILAR LOCATION TO EXISTING HYDRANT. EX. 12" ASBESTOS CEMENT W/L (FW) (SEE NOTES, C-07) 6" DIP CL52 W/L 'D' (FW)1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS 770 775 780 785 790 795 800 805 810 770 775 780 785 790 795 800 805 810 10+00 11+00 WL-Fire-Private 775 780 785 790 795 800 805 810 815 775 780 785 790 795 800 805 810 815 10+00 11+00 11+50 765 770 775 780 785 790 795 800 805 765 770 775 780 785 790 795 800 805 10+00 11+00 12+00STA. 10+00.00CORP. STOPSTA. 10+06.003" PVC SDR 21 CASINGSTA. 10+60.00BLDG. CONN.STA. 10+05.005/8" W.M. (TRAFFIC-RATED)STA. 10+42.003" PVC SDR 21 CASINGSTA. 10+00.00BLDG. CONN.STA. 10+05.0045° BENDSTA. 10+50.2545° BENDSTA. 10+69.68BLDG. CONN.18" MIN. CLEAR (TYP.)STA. 10+14.9018" STM X-INGINV. = 786.1148" MIN. COVER 48" MIN. COVER PROPOSED GRADEPROPOSED GRADE 6" DIP CL 52 W/L (PRIVATE) 1" CTS PET W/L (200 PSI - PRIVATE) 36LF - 3" PVC SDR 21 CASING STA. 11+50.34BLDG. CONN.INV. = 783.44STA. 11+34.34C.O. @ 45° BENDTOP = 788.75INV. = 782.99STA. 10+36.39C.O. @ 45° BENDTOP = 790.50INV. = 780.23STA. 10+00.00EX. M/H (EX. TOP = 787.39)RAISE TOP TO 790.50CORE NEW INV. IN @ 779.20 (4")GROUT EX. INV. IN @ 779.00 (6")EX. INV. OUT = 779.00 (6")(ALL WORK @ M/H PER FWINSPECTOR REQUIREMENTS)150.34LF - 4" SDR 35/26 PVC SAN. SEW. @ 2.82% PROPOSED GRADE STA. 10+29.048" W/L X-INGSTA. 10+72.128" W/L X-INGSTA. 10+19.1718" STM X-INGINV. = 781.7436" MIN. COVER 18" MIN. CLEAR (TYP.)STA. 10+43.1816" PVC CASINGSTA. 10+23.1816" PVC CASINGSTA. 10+17.9045° VERT. BENDSTA. 10+20.5145° VERT. BENDSTA. 10+46.1811.25° VERT. BENDSTA. 10+56.2211.25° VERT. BENDSTA. 10+55.0515" STM X-INGINV. = 782.93STA. 10+57.1212" PVC CASINGSTA. 10+87.1212" PVC CASING30LF - 12" SCH. 40 PVC CASING 20LF - 16" SCH. 40 PVC CASING10+0010+70 X X X X79479479479478478478878878678879479279078879079279479079079079079479279410+00 10+60 X XXXXX794794 794794 788 788786788794 792 790 79079079479279410+00 11+0011+50XXX XX788 788786788794 792 790 790790794792794CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYWATERLINE AND SANITARY SEWERPLAN & PROFILEJOB NO.: 22-01 C-19C-19.DWGDDDDDDDESCRIPTION06-28-2022AS SHOWNWATERLINE 'E' (PRIVATE) 02-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VAWATERLINE 'F' (PRIVATE)SANITARY SERVICE TO OFFICE (PRIVATE)WWW W W W W W W WWWWWWWWWWW W W WSTA. 10+00.00 BLDG. CONN. FDC 45° BEND STA. 10+69.68 BLDG. CONN. 6" DIP CL52 W/L 'E' (PRIVATE) W W WWWWWWWWWW W W WWW STA. 10+00.00 CORP. STOP STA. 10+60.00 BLDG. CONN. 1" CTS PET W/L 'F' (PRIVATE) 5/8" W.M. (TRAFFIC RATED FRAME & LID W/ (2) BOLLARDS) 36LF - 3" PVC SDR 21 CASING OFFICE STA. 10+00.00 EX. M/H (TOP = 787.39) RAISE TOP TO 790.50 EX. INV. IN = 790.00 (6") (GROUT) CORE NEW INV. IN @ 790.00 (4") EX. INV. OUT = 790.00 (6") (ALL WORK @ M/H PER FW INSPECTOR REQUIREMENTS) STA. 11+50.34 BLDG. CONN. C.O. @ 45° BEND C.O. @ 45° BEND 150.34LF - 4" SDR 35/26 PVC SAN. SEW. @ 2.82% (PRIVATE)1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22 30LF - 12" SCH. 40 PVC CASING W W W W WWWWWWWWW W 302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS20LF - 16" SCH. 40 PVC SDR 21 CASING CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYUTILITY DETAILSJOB NO.: 22-01 C-20C-20.DWGDDDN/ADDDDESCRIPTION06-28-202202-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VA1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYLIGHTING DETAILSJOB NO.: 22-01 C-21C-21.DWGDDDN/ADDDDESCRIPTION06-28-202202-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VA1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYLIGHTING DETAILSJOB NO.: 22-01 C-22C-22.DWGDDDN/ADDDDESCRIPTION06-28-202202-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VA1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS EROSION CONTROL NOTES:SEEDING SPECIFICATIONS TEMPORARY CONTROL MEASURES: TEMPORARY SOIL EROSION AND SEDIMENT CONTROL MEASURES WILL BE INSTALLED PRIOR TO ANY MAJOR SOIL DISTURBANCE IN ORDER TO PREVENT ACCELERATED EROSION AND TRANSPORTATION OF SEDIMENT DURING SITE DISTURBANCE. SILT FENCE WILL BE USED TO LIMIT SEDIMENTATION FROM SMALL UPHILL AREAS. ANY DISTURBED AREAS THAT WILL BE LEFT EXPOSED MORE THAN 7 DAYS, AND NOT SUBJECT TO CONSTRUCTION TRAFFIC WILL IMMEDIATELY RECEIVE TEMPORARY SEEDING AND MULCH. IF THE SEASON PREVENTS ESTABLISHMENT OF TEMPORARY COVER, THE DISTURBED AREAS WILL BE MULCHED WITH STRAW, OR EQUIVALENT MATERIAL AT A RATE OF 2.0 TONS PER ACRE. ALL CRITICAL AREAS (I.E. STEEP SLOPES AND ROADWAY EMBANKMENTS) WILL RECEIVE A TEMPORARY SEEDING IMMEDIATELY FOLLOWING THE ESTABLISHMENT OF FINAL GRADE IN COMBINATION WITH STRAW OR MULCH, OR A SUITABLE EQUIVALENT AT A RATE OF 2.0 TONS PER ACRE. THE DESIGN OF THE PROJECT INTENDS TO DISTURB AS LITTLE OF THE SITE AS POSSIBLE. SEED: FALL - RYE, TWO ½ BUSHELS PER ACRE [SEPTEMBER 1 - NOVEMBER 15] SPRING - OATS, TWO ½ BUSHELS PER ACRE [MARCH 1 - MAY 15] MULCH: 2.0 TONS PER ACRE MULCH BINDER: EMULSIFIED ASPHALT SS-1 AT THE RATE OF 150 GALLONS PER ACRE FERTILIZER: 3 TON DOLOMITIC LIMESTONE/ACRE; 600 LBS.; 10-10-10/ACRE PERMANENT CONTROL MEASURES: PERMANENT CONTROL MEASURES WILL BE INSTALLED IN THEIR PROPER SEQUENCE THROUGHOUT THE CONSTRUCTION PERIOD. THESE MEASURES WILL PREVENT EROSION ONCE CONSTRUCTION ACTIVITY IS COMPLETE. PERMANENT CONTROL MEASURES FOR THIS PROJECT INCLUDE THE ESTABLISHMENT OF PERMANENT COVER AND INSTALLATION OF RIP-RAP APRONS AT STORM PIPE OUTLETS. ALL AREAS SHALL BE PERMANENTLY SEEDED AND MULCHED WITHIN ONE WEEK OF REACHING FINAL GRADE, OTHERWISE TEMPORARY REQUIREMENTS SHALL BE MET. ADDITIONALLY, ALL AREAS SHALL BE SEEDED AND MULCHED WITHIN 7 DAYS IF THE AREA IS TO REMAIN UNWORKED FOR A PERIOD OF 14 DAYS OR MORE. DURING THE FIRST GROWING SEASON AFTER REACHING FINAL GRADE, A PERMANENT SEED MIXTURE WILL BE ADDED. ANY SOIL THAT WILL NOT PROVIDE A SUITABLE ENVIRONMENT TO SUPPORT ADEQUATE VEGETATIVE GROUND COVER, SHALL BE REMOVED OR TREATED IN SUCH A WAY THAT WILL PERMANENTLY ADJUST THE SOIL CONDITIONS AND RENDER IT SUITABLE FOR VEGETATIVE GROUND COVER. IF THE REMOVAL OR TREATMENT OF THE SOIL WILL NOT PROVIDE SUITABLE CONDITIONS, NON-VEGETATIVE MEANS OF PERMANENT GROUND STABILIZATION WILL HAVE TO BE EMPLOYED. ALL ROADWAY SLOPES AND DISTURBED AREAS ARE TO BE SEEDED AND MULCHED. GROUND IS TO BE DISCED TO A DEPTH OF SIX (6) INCHES AND SEEDED AS SOON AS POSSIBLE AFTER GROUND HAS BEEN DISTURBED. 10-20-10 FERTILIZER IS TO BE APPLIED AT THE RATE OF 1000 LBS PER ACRE AND LIME AT THREE TONS PER ACRE PRIOR TO DISCING. MULCHING IS TO BE 2.0 TONS OF STRAW WITH 100 GALLONS OF TAR MIXED PER ACRE. ALL WORK SHALL BE DONE IN ACCORDANCE WITH SOIL CONSERVATION SERVICE STANDARDS. PERMANENT SEEDING (MARCH 1 -SEPT. 1 ) WILL BE APPLIED AS FOLLOWS: SEED: 150 LBS/ACRE KENTUCKY 31 - 90% RED TOP GRASS - 5% WHITE CLOVER - 5% FERTILIZER: 2 TONS DOLOMITIC LIMESTONE/ACRE; 1000 LBS/ACRE OF 10/20/10 MULCH: 2.0 TONS/ACRE OF STRAW CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYE&SC NOTESJOB NO.: 22-01 C-23C-23.DWGDDDN/ADDD1.THE CONTRACTOR SHALL ARRANGE FOR A PRE-CONSTRUCTION CONFERENCE WITH THE FREDERICK COUNTY EROSION AND SEDIMENT CONTROL DIRECTOR 48 HOURS PRIOR TO BEGINNING WORK. 2.ALL EROSION CONTROL DEVICES AS SHOWN OR AS REQUIRED ARE TO BE CONSTRUCTED TO STANDARDS AND SPECIFICATIONS OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK (LATEST EDITION) AND ARE TO BE IN PLACE PRIOR TO ALL CONSTRUCTION. 3.THIS PLAN IS NOT COMPLETE WITHOUT THE APPROVED NARRATIVE. 4.EROSION AND SEDIMENT CONTROL MEASURES SHALL BE MAINTAINED CONTINUOUSLY, RELOCATED WHEN AND AS NECESSARY AND SHALL BE CHECKED AFTER EVERY RAINFALL. SEEDED AREAS SHALL BE CHECKED REGULARLY AND SHALL BE WATERED, FERTILIZED, RESEEDED AND MULCHED AS NECESSARY TO OBTAIN A DENSE STAND OF GRASS. 5.ALL DISTURBED AREAS NOT PAVED OR BUILT UPON ARE TO BE FERTILIZED, SEEDED, AND MULCHED BY THE CONTRACTOR IN ACCORDANCE WITH THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK (LATEST EDITION). 6.ALL DRAIN INLETS SHALL BE PROTECTED FROM SILTATION. INEFFECTIVE PROTECTION DEVICES SHALL BE IMMEDIATELY REPLACED AND THE INLET CLEANED. FLUSHING IS NOT AN ACCEPTABLE METHOD OF CLEANING. 7.GRADE AREAS ADJACENT TO BUILDING TO ACHIEVE DRAINAGE AWAY FROM THE STRUCTURE AND TO PREVENT PONDING IN SWALES. 8.PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN SEVEN DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN DORMANT (UNDISTURBED) FOR LONGER THAN 21 DAYS. 9.DURING CONSTRUCTION OF THE PROJECT, SOIL STOCKPILES SHALL BE STABILIZED OR PROTECTED WITH SEDIMENT TRAPPING MEASURES. 10.VEGETATIVE STABILIZATION SHALL BE UNIFORM AND MATURE ENOUGH TO SURVIVE AND ADEQUATE TO INHIBIT EROSION. 11.SEDIMENT BASINS AND TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS AND OTHER MEASURES INTENDED TO TRAP SEDIMENT SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND- DISTURBING ACTIVITY AND SHALL BE MADE FUNCTIONAL BEFORE UPSLOPE LAND DISTURBANCE TAKES PLACE. 12.STABILIZATION MEASURES SHALL BE APPLIED TO EARTHEN STRUCTURES SUCH AS DAMS, DIKES AND DIVERSIONS IMMEDIATELY AFTER INSTALLATION. 13.UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TO OTHER APPLICABLE CRITERIA: A.NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME. B.EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES. C.EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVED SEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER THAT DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFF-SITE PROPERTY. D.MATERIAL USED FOR BACK FILLING TRENCHES SHALL BE PROPERLY COMPACTED IN ORDER TO MINIMIZE EROSION AND PROMOTE STABILIZATION. E.RESTABILIZATION SHALL BE ACCOMPANIED IN ACCORDANCE WITH THESE REGULATIONS. F.APPLICABLE SAFETY REGULATIONS SHALL BE COMPLIED WITH. 14.WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED PUBLIC ROADS, PROVISIONS SHALL BE MADE TO MINIMIZE THE TRANSPORT OF SEDIMENT BY VEHICULAR TRACKING ONTO THE PAVED SURFACE. WHERE SEDIMENT IS TRANSPORTED ONTO A PUBLIC ROAD SURFACE, THE ROAD SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM THE ROADS BY SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. 15.ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, UNLESS OTHERWISE AUTHORIZED BY THE LOCAL PROGRAM ADMINISTRATOR. TRAPPED SEDIMENT AND THE DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES SHALL BE PERMANENTLY STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION. 16.ALL DISTURBED AREAS NOT PAVED OR BUILT UPON SHALL BE TOP SEEDED, MULCHED AND FERTILIZED. PERFORM PERMANENT TOP SOILING, SEEDING, LANDSCAPING, FERTILIZING, AND MULCHING AS SOON AFTER FINISH GRADING AS POSSIBLE. SEEDING SHALL COMPLY WITH THE FOLLOWING: A.TOPSOIL - 4 INCH MINIMUM FOR PERMANENT TURF B.FERTILIZER - 450 POUNDS PER ACRES OF 10-20-10 FERTILIZER OR EQUIVALENT POUNDAGE OF DIFFERENT ANALYSIS. WORK INTO SOIL PRIOR TO SEEDING. C.LIME (PERMANENT SEEDING) - AGRICULTURAL LIME SPREAD AT RATE OF 2 TONS/ACRE. WORK INTO SOIL PRIOR TO SEEDING. D.MULCH-CHOPPED STRAW AT RATE OF 2 TON PER ACRE AND TACKED IN PLACE. HYDRO-MULCH AT RATE OF 30 BALES PER ACRE.DESCRIPTION06-28-202202-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VA1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS DUST CONTROL MEASURES SIDE ELEVATION PLAN VIEW SECTION A-A SECTION B-B STONE CONSTRUCTION ENTRANCE TEMPORARY DIVERSION DIKE CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYE&SC DETAILSJOB NO.: 22-01 C-24C-24.DWGDDDN/ADDDDESCRIPTION06-28-202202-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VASCC #3 Q2 = 0.70 CFS Q10 = 0.95 CFS 2-YR VEL. = 1.39 FT/S 10-YR. DEPTH = 0.43' LINING = GRASS SCC #1 Q2 = 0.30 CFS Q10 = 0.40 CFS 2-YR VEL. = 1.67 FT/S 10-YR. DEPTH = 0.09' LINING = RIP-RAP (CLASS A1) SCC #2 Q2 = 0.33 CFS Q10 = 0.45 CFS 2-YR VEL. = 1.91 FT/S 10-YR. DEPTH = 0.26' LINING = GRASS GABION BASKET DETAIL WIRE CAGE GABION BASKET NOTES: 1.CLASS A-1 RIP-RAP TO BE USED FOR FILLING AND PLACEMENT ALONG EXTERIOR OF GABION BASKETS. 2.REFER TO PLAN SHEETS FOR HEIGHT REQUIREMENTS. BOTTOM OF BASIN/FOREBAY PLACE ADDITIONAL RIP-RAP NOT TO SCALE 1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYSWM NOTES & DETAILSJOB NO.: 22-01 C-25C-25.DWGDDDN/ADDDDESCRIPTION06-28-202202-01-2023 ELEV. = 790.50 18" HDPE @ 1.00% 60. 0 0 L FBOTTOM OF BASIN = 782.00 2:13:1 8' 8" 6' SQUARE INV.=782.00 RISER TO BE EMBEDDED 4" INTO THE CONCRETE FOOTING 3000 PSI CONC. FOOTING IF NECESSARY, CONTRACTOR TO EXCAVATE UNSUITABLE BASE MATERIAL THAT EXISTS BELOW BASE OF RISER AND REPLACE WITH COMPACTED UNCLASSIFIED FILL 20' WIDE EMERG. SPILLWAY ELEV. = 788.50 4' DIA. VDOT SWM-1 TOP=787.50 TRASH RACK 5' x 5' ANTI-SEEP COLLAR TOP OF WET STORAGE ELEV. = 784.75 TOP OF DRY STORAGE ELEV. = 786.25 6" PERFORATED POLYETHYLENE TUBING (PERFORATED ABOVE 784.75) W/ POLYETHYLENE CAP 784.98 785.25 786.52 788.21-- BARE EARTH, CN = 91 10 YR. 1 YR. 2 YR. 100 YR. 787.3825 YR. 4" DEWATERING ORIFICE INV.=782.00SEDIMENT CLEANOUT ELEV. = 783.75 WET STORAGE = 1809 CU. FT./AC. DRY STORAGE = 1809 CU. FT./AC) SEDIMENT BASIN NOT TO SCALE WINCHESTER SECURE STORAGEFREDERICK COUNTY, VANOTE: EXISTING ELEVATION THROUGH CENTER OF BASIN IS ~788, THEREFORE SINCE THE BASIN IS EXCAVATED NO CUT-OFF TRENCH IS REQUIRED. ELEV. = 790.50 18" HDPE @ 1.00% 60. 0 0 L F BOTTOM OF BASIN = 782.00 2:1SWMB 'A' PRINCIPAL SPILLWAY NOT TO SCALE 3:1 8' 8" 6' SQUARE CONVERSION OF SEDIMENT BASIN TO PERMANENT STORM WATER MANAGEMENT BASIN NOTES THE FOLLOWING ITEMS NEED TO BE ADDRESSED TO COMPLETE THE CONVERSION: 1.REMOVE PERFORATED POLYETHYLENE TUBING. 2.REMOVE SEDIMENT FROM BASIN. 3.CUT NEW 8" ORIFICE IN METAL PLATE OVER EX. 4" ORIFICE AND AFFIX DEBRIS RACK PER VDOT SWM-1. 785.17 785.90 787.48 788.87 10 YR. 1 YR. 2 YR. 100 YR. 788.0225 YR. 789.37 (100% THRU EMERG. SPILLWAY)100 YR. INV.=782.00 8" ORIFICE W/ TRASH RACK INV.=782.00 RISER TO BE EMBEDDED MIN. 4" INTO THE CONCRETE FOOTING 3000 PSI CONC. FOOTING IF NECESSARY, CONTRACTOR TO EXCAVATE UNSUITABLE BASE MATERIAL THAT EXISTS BELOW BASE OF RISER AND REPLACE WITH COMPACTED UNCLASSIFIED FILL OUTLET PROTECTION 20' WIDE EMERG. SPILLWAY ELEV. = 788.50 4' DIA. VDOT SWM-1 TOP=787.50 TRASH RACK 5' x 5' ANTI-SEEP COLLAR BASE = 685.00 STORMWATER MANAGEMENT BASIN NOTES: 1. ALL STORMWATER MANAGEMENT POND CONSTRUCTION SHALL BE IN STRICT COMPLIANCE WITH ALL APPLICABLE FREDERICK COUNTY AND THE U.S. DEPARTMENT OF AGRICULTURE SOIL CONSERVATION SERVICE STANDARDS AND SPECIFICATIONS 2. MATERIAL. SITE AND STORMWATER MANAGEMENT BASIN FILL MATERIAL SHALL BE TAKEN FROM APPROVED DESIGNATED BORROW AREAS. IT SHALL BE FREE OF ROOTS, STUMPS, WOOD, RUBBISH, STONES WITH DIAMETERS GREATER THAN 6 INCHES, AND FROZEN OR OTHER OBJECTIONABLE MATERIALS. 3. COMPACTION. BACKFILL SHALL BE SPREAD IN HORIZONTAL LIFTS WHICH DO NOT EXCEED 4 INCHES AND COMPACTED. THE MOVEMENT OF THE HAULING AND SPREADING EQUIPMENT OVER THE FILL SHALL BE CONTROLLED SO THAT THE ENTIRE SURFACE OF EACH LIFT SHALL BE TRAVERSED BY NOT LESS THAN ONE TREAD TRACK OF HEAVY EQUIPMENT OR COMPACTION SHALL BE ACHIEVED BY A MINIMUM OF 4 COMPLETE PASSES OF A SHEEPSFOOT, RUBBER-TIRED OR VIBRATORY ROLLER. FILL MATERIAL SHALL CONTAIN SUFFICIENT MOISTURE SUCH THAT THE REQUIRED DEGREE OF COMPACTION WILL BE OBTAINED WITH THE EQUIPMENT USED. THE FILL MATERIAL SHALL CONTAIN SUFFICIENT MOISTURE SO THAT IF FORMED INTO A BALL IT WILL NOT CRUMBLE, YET NOT SO WET THAT WATER CAN BE SQUEEZED OUT. THE MINIMUM REQUIRED DENSITY OF THE COMPACTED BACKFILL SHALL NOT BE LESS THAN 95% OF MAXIMUM DRY DENSITY WITH A MOISTURE CONTENT WITHIN 2% OF THE OPTIMUM. EACH LAYER OF FILL SHALL BE COMPACTED AS NECESSARY TO OBTAIN THAT DENSITY, AND IS TO BE CERTIFIED BY THE ENGINEER AT THE TIME OF CONSTRUCTION. 4. VEGETATION. NO TREES OR SHRUBS SHALL BE PLANTED ON ANY EMBANKMENT OF THE STORMWATER MANAGEMENT BASINS. SWM MAINTENANCE SCHEDULE 1. POST CONSTRUCTION STORM-WATER MANAGEMENT: THE FOLLOWING CONTROL MEASURES SHALL BE IMPLEMENTED TO REDUCE POLLUTANTS IN STORM-WATER DISCHARGE AFTER THE HEAVY SITE CIVIL CONSTRUCTION PHASES HAVE BEEN COMPLETED AT THE SITE. A. ROUTINE INSPECTION OF DRAINAGE WAYS BEFORE AND AFTER STORM SEASONS, INCLUDING CLEANING AND REMOVAL OF SEDIMENT AND DEBRIS. B. IMPLEMENTATION OF EROSION CONTROL MEASURES AS NEEDED IN THE LONG-TERM TO MITIGATE THE EFFECTS OF EROSION ON OPEN SLOPES ADJACENT TO AND WITHIN THE DEVELOPMENT. C. PERMANENT RE-VEGETATION OF THE FILL SLOPES USING PROVEN TECHNIQUES UPON COMPLETION. D. REGULAR STREET AND PARKING LOT SWEEPING TO COLLECT SEDIMENT AFTER/BEFORE RUNOFF EVENTS AND TO PREVENT DUST POLLUTION. 2. MAINTENANCE AND INSPECTION: THE STORM-WATER POLLUTION PREVENTION PLAN SHALL INCLUDE MAINTENANCE, REPAIR, AND TRACKING PROCEDURES TO ENSURE THAT ALL GRADED SURFACES AND MITIGATION MEASURES, AND OTHER PROTECTIVE DEVICES, IN SITE PLAN, ARE MAINTAINED IN A GOOD AND EFFECTIVE CONDITION, AND ARE REPAIRED OR RESTORED IF DAMAGED. 3. GENERAL PROCEDURE: ALL MITIGATION MEASURES SHALL BE INSPECTED AFTER EACH AND EVERY MAJOR STORM EVENT. A STORM EVENT IS DEFINED AS A RAINFALL EVENT WHERE MORE THAN 1/2" OF RAINFALL OCCURS DURING A 24 HOUR PERIOD. REPAIRS SHALL BE MADE TO ALL MITIGATION DEVICES UPON DISCOVERY OF DAMAGE. ADDITIONALLY, MONTHLY INSPECTION SHALL OCCUR UNTIL THE NOTICE OF TERMINATION (NOT) IS FILED. 4. RECORD KEEPING DOCUMENTATION: RECORDS OF ALL INSPECTION, COMPLIANCE CERTIFICATION, AND NON-COMPLIANCE REPORTING WILL BE RETAINED FOR A PERIOD OF AT LEAST 3 YEAR. A COPY OF THIS STORM-WATER POLLUTION PREVENTION PLAN WILL BE KEPT ONSITE DURING ALL CONSTRUCTION ACTIVITIES.1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYCONSTRUCTION DETAILSJOB NO.: 22-01 C-26C-26.DWGDDDN/ADDDHANDICAPPED USE SYMBOL 3' 7' HANDICAPPED PARKING STALL STANDARD STOP SIGN HANDICAPPED USE SIGN CONCRETE SIDEWALK DETAIL TURN-DOWN SIDEWALK DETAIL DESCRIPTION06-28-202202-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VA1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTSHVAC PAD DETAIL CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYCONSTRUCTION DETAILSJOB NO.: 22-01 C-27C-27.DWGDDDN/ADDDDESCRIPTION06-28-202202-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VA1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYCONSTRUCTION DETAILSJOB NO.: 22-01 C-28C-28.DWGDDDN/ADDDDESCRIPTION06-28-202202-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VANOTE: 1.WHERE PLANS INDICATE CG-6R (REVERSE GUTTER PAN, THE GUTTER SLOPE WILL PITCH AT THE SAME 1":1' SLOPE BUT AWAY FROM THE CURB.1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYCONSTRUCTION DETAILSJOB NO.: 22-01 C-29C-29.DWGDDDN/ADDDDESCRIPTION06-28-202202-01-2023 WINCHESTER SECURE STORAGEFREDERICK COUNTY, VA1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYCONSTRUCTION DETAILSJOB NO.: 22-01 C-30C-30.DWGDDDN/ADDDDESCRIPTION06-28-202202-01-2023 Transportation Management Plan 1.Temporary Traffic Control Plan a.General Notes 1.This project is classified as a TMP Type “A” project. Traffic on the project is commercial with an employee vehicle and customer usage with minimal commercial trucks. The traffic volume for the mainline is 19,000 ADT with a posted 45 MPH speed limit. 2.The project is located on North Frederick Pike in Frederick County, approximately 400' west of the intersection with Darlington Drive (Rte. 1311). 3.The work consists of installing a new commercial entrance and the extension of a right-turn lane. The existing road is a two lane section with approximate 12' lanes and a right-turn lane extending to the western property line from the existing entrance. 4.The work zone will be approximately 500 feet in length at the entrance. 5. The work zone will consist of a shoulder closure following the Virginia Work Area Protection Manual (VWAPM) and the MUTCD. 6.The work zone will be in operation Monday through Friday, during day light hours. 7.The contractor shall provide an intermediate level Work Zone Safety Coordinator to develop the work zone and at least a basic level Work Zone Safety Coordinator to monitor and maintain the work zone. 8.The shoulder closure will follow TTC-5.0 of the VWAPM. Signing project limits will follow TTC-53.0 of the VWAPM. 9.The contractor shall submit a detailed traffic control plan to VDOT for review 14 days prior to any construction on VDOT Right-of-Way. 10.The contractor shall maintain adequate access and sight distance to all properties. Emergency Vehicles and Postal Vehicles shall have access to properties at all times. 11.All equipment and material storage shall be located outside of the clear zone. The clear zone for this project is 15' beyond the edge of the existing pavement. 12.Entrances, Intersections, and Pedestrian Access: There are no intersections or pedestrian accesses impacted by the site development. b)Refer to this sheet of the Site Plan Document for typical sections, details, and layout of the lane configurations within the work zone per the Virginia Work Area Protection Manual and the Manual on Uniform Traffic Control Devices. 2.Public Communications Plan a.The Contractor shall notify the VDOT Project Manager/Residency Administrator of scheduled work plans and traffic delays a minimum of seven (7) days prior implementation of the work. VDOT will provide project information to the Staunton District Public Affairs in advance of the start of construction and weekly updates by noon on Thursday for the following weeks work. Changes in the work plans shall be made immediately known to VDOT. b.The Contractor shall notify the VDOT Project Manager/Residency Administrator of any unscheduled traffic delays immediately upon knowing the change to the work schedule.WINCHESTER SECURE STORAGEFREDERICK COUNTY, VA1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS11-10-2022DDD2REVISIONS TO BUILDING FOOTPRINT AND PARKING LAYOUT 12-28-2022DDDFREDERICK COUNTY SP #42-22302-01-2023DDDREVISIONS PER FREDERICK COUNTY AGENCY COMMENTS