HomeMy WebLinkAbout06-22 Design PlanPROJ FILE# 50128634
Sheet Of1 10
PRE-172
WILLOW RUN
SHEET INDEX
VICINITY MAP
SCALE: 1" = 2,000'
APPROVED BY THE FREDERICK COUNTY ADMINISTRATOR
DATE
LOCAL UTILITIESOWNER
CIVIL ENGINEER
DEVELOPER
COUNTY REVISIONS
DATENO.DESCRIPTION BY
DEWBERRY REVISIONS
DESCRIPTIONDATENO.BY
BACK CREEK MAGISTERIAL DISTRICT
FREDERICK COUNTY, VIRGINIA
TAX MAP #: 53-A-91 & 63-A-2A
ADDRESS: 964 CEDAR CREEK GRADE
PROPOSED USE: RESIDENTIAL DEVELOPMENT
ZONING: RP, RESIDENTIAL PERFORMANCE DISTRICT (SMALL LOT)
PER REZONING RZ# 02-21
PROJECT NUMBER:MDP #06-22
DATE: JUNE 30, 2022
Dewberry
Engineers Inc.
13575 HEATHCOTE BLVD.
SUITE 130
GAINESVILLE, VA 20155-6693
PHONE: 703.468.2211
FAX: 703.468.2212
APPROVED BY THE DIRECTOR OF PLANNING AND DEVELOPMENT
DATE
PROJ FILE# 50128634
BY
RELATED APPROVED PLANS:
REZ #06-12, REZ #21-06, REZ #11-08
Drawn By
Plan Number
Checked By
Designed By
File Number
PRE-172
Sheet
Scale
Date
10OfWILLOW RUNMASTER DEVELOPMENT PLANFrederick County, VirginiaCOUNTY REVISIONS
DATENO.DESCRIPTION BY
DEWBERRY REVISIONS
DESCRIPTIONDATENO.BY DewberryEngineers Inc.13575 HEATHCOTE BLVD.SUITE 130GAINESVILLE, VA 20155-6693PHONE: 703.468.2211FAX: 703.468.2212MDP #06-22
6/30/2021
2
1" = 200'
AD
ZTMASTER PLANPROJECT SUMMARY
PIN NUMBERS: 53-A-91 & 63-A-2A
TOTAL PARCELS AREA: 119.5 AC
MDP AREA: 119.5 AC
PROPOSED USE: AGE-RESTRICTED SINGLE FAMILY DETACHED & DUPLEX
EXISTING LOT AREA (53-A-91)......112.4 AC
EXISTING LOT AREA (63-A-2A)......7.1 AC
ZONING...............................................RP
CURRENT USE....................................RESIDENTIAL/VACANT
LEGEND
PROPERTY BOUNDARY
MDP BOUNDARY
WETLANDS
PROPOSED AREA FOR
SF DETACHED LOTS
PROPOSED AREA FOR
DUPLEX LOTS
DISTURBED OPEN SPACE
UNDISTURBED OPEN SPACE
PROPOSED AREA FOR
RECREATIONAL CENTER
DIMENSIONAL REQUIREMENTS
FOR RESIDENTIAL PERFORMANCE (RP) SMALL LOTS
RECREATIONAL UNITS CALCULATION
REQUIRED:
1 UNIT PER 30 DWELLING UNITS
300 DWELLING UNITS/30 = 10 RECREATIONAL UNITS
PROVIDED:
COMMUNITY CENTER (approx. 3,000 sf) 3
POOL (approx. 3,500 sf)1
2 TENNIS/PICKLE BALL COURTS 2
2 BOCCE BALL COURTS 2
PEDESTRIAN SIDEWALK CIRCULATION 1
BENCH AREA 1
TOTAL PROVIDED =10 UNITS
NOTE: FACILITY TYPES AND LOCATIONS SHOWN ARE
PRELIMINARY AND SUBJECT TO CHANGE WITH FINAL
DESIGN.
Drawn By
Plan Number
Checked By
Designed By
File Number
PRE-172
Sheet
Scale
Date
10OfWILLOW RUNMASTER DEVELOPMENT PLANFrederick County, VirginiaCOUNTY REVISIONS
DATENO.DESCRIPTION BY
DEWBERRY REVISIONS
DESCRIPTIONDATENO.BY DewberryEngineers Inc.13575 HEATHCOTE BLVD.SUITE 130GAINESVILLE, VA 20155-6693PHONE: 703.468.2211FAX: 703.468.2212MDP #06-22
6/30/2021
3
1" = 200'
AD
ZTROAD PLANNOTES:
1. ALL PUBLIC AND PRIVATE ROADS TO BE CONSTRUCTED PER VDOT STANDARDS.
2. ALL STREETS TO BE PRIVATE PER PROFFERS. ALL PRIVATE STREETS TO BE
APPROVED BY BOARD OF SUPERVISORS PER COUNTY CODE.
3. CONCEPTUAL ROAD LAYOUT IS SUBJECT TO MINOR CHANGES WITH FINAL
ENGINEERING.
Drawn By
Plan Number
Checked By
Designed By
File Number
PRE-172
Sheet
Scale
Date
10OfWILLOW RUNMASTER DEVELOPMENT PLANFrederick County, VirginiaCOUNTY REVISIONS
DATENO.DESCRIPTION BY DewberryEngineers Inc.13575 HEATHCOTE BLVD.SUITE 130GAINESVILLE, VA 20155-6693PHONE: 703.468.2211FAX: 703.468.2212MDP #06-22
6/30/2021
4
1" = 100'
AD
ZTENVIRONMENTAL ANDUTILITIES PLANLEGEND
PROPERTY BOUNDARY;
MDP BOUNDARY
STEEP SLOPES (>35%) =+/-0.83 AC.
(+/- 0.21 AC. ARE DISTURBED)
FLOODPLAIN +/- 18.06 AC.
WETLANDS
PROPOSED WATER MAIN
PROPOSED SANITARY MAIN
PROPOSED STORM SEWER
PROPOSED 5' SIDEWALK
STORM/RUNOFF DIRECTION
FP
NOTES:
1. TWO (2) FOOT CONTOUR INTERVAL SHOWN ON THIS PLAN FROM TOPOGRAPHIC
MAPPING PREPARED BY MRA, SEPTEMBER 2021.
2. BOUNDARY INFORMATION PER BOUNDARY SURVEY PREPARED BY DEWBERRY,
SEPTEMBER 2020.
3. ALL PUBLIC AND PRIVATE ROADS TO BE CONSTRUCTED PER VDOT STANDARDS.
4. ALL STREETS TO BE PRIVATE PER PROFFERS. ALL PRIVATE STREETS TO BE APPROVED
BY BOARD OF SUPERVISORS PER COUNTY CODE.
5. ALL PROPOSED UTILITIES ARE TO BE PLACED UNDERGROUND WITH THE EXCEPTION OF
THE OVERHEAD POWER LINE.
6. STORMWATER MANAGEMENT & BEST MANAGEMENT PRACTICE (SWM/BMP) CONCEPT
SHOWN FOR SCHEMATIC PURPOSES AND IS SUBJECT TO CHANGE WITH FINAL
ENGINEERING AND DESIGN PLAN SUBMISSION.
7. UTILITY LOCATIONS (STORM, SANITARY SEWER AND WATER) ARE SHOWN FOR
SCHEMATIC PURPOSES AND ARE SUBJECT TO CHANGE WITH FINAL ENGINEERING AND
DESIGN PLAN SUBMISSION.
8. THE PROPOSED SANITARY SEWER SYSTEM WILL FLOW TO THE ON-SITE PUMP STATION
TO BE PUMPED TO THE EXISTING FORCE MAIN. THIS EXISTING SANITARY SEWER
SYSTEM IS PART OF THE FREDERICK WATER SANITARY SEWER SYSTEM.
9. THE PROPOSED WATER DISTRIBUTION SYSTEM WILL CONNECT TO THE EXISTING WATER
DISTRIBUTION SYSTEMS WEST OF THE PROJECT SITE AND NEAR MERRIMANS LANE. THE
EXISTING WATER DISTRIBUTION SYSTEM IS PART OF THE FREDERICK WATER WATER
SYSTEM. THE WATER MAIN WITHIN THE DEVELOPMENT WILL BE 8" DIAMETER. THE
WATER MAIN SIZE FOR THE CONNECTION WILL BE DETERMINED WITH FINAL
ENGINEERING.
10. ELECTRIC, GAS, AND COMMUNICATION UTILITIES WILL BE COORDINATED DURING FINAL
ENGINEERING PRIOR TO CONSTRUCTION.
11. NO HISTORICAL STRUCTURES OR SITES ARE KNOWN TO EXISTING WITHIN THE PROJECT
LIMITS SHOWN ON THIS PLAN.
12. DSA AREA OR WETLAND DELINEATION SHOWN ON THIS PLAN PROVIDED BY OTHERS.
13. OPEN SPACE SHOWN HEREON IS APPROXIMATE AND SUBJECT TO MODIFICATION WITH
FINAL ENGINEERING AND DESIGN PLAN SUBMISSION.
14.ALL SIGNAGE WILL CONFORM TO FREDERICK COUNTY ZONING ORDINANCE §165-201.06
15.ALL LIGHTING WILL CONFORM TO FREDERICK COUNTY ZONING ORDINANCE §165-201.07
16. ALL LANDSCAPING WILL CONFORM TO FREDERICK COUNTY ZONING ORDINANCE
§165-203.01.
17. NO BLASTING WITHIN 300 FEET OF CITY OF WINCHESTER UTILITY LINES.
Drawn By
Plan Number
Checked By
Designed By
File Number
PRE-172
Sheet
Scale
Date
10OfWILLOW RUNMASTER DEVELOPMENT PLANFrederick County, VirginiaCOUNTY REVISIONS
DATENO.DESCRIPTION BY DewberryEngineers Inc.13575 HEATHCOTE BLVD.SUITE 130GAINESVILLE, VA 20155-6693PHONE: 703.468.2211FAX: 703.468.2212MDP #06-22
6/30/2021
5
1" = 100'
AD
ZTENVIRONMENTAL ANDUTILITIES PLANLEGEND
PROPERTY BOUNDARY;
MDP BOUNDARY
STEEP SLOPES (>35%) =+/-0.83 AC.
(+/- 0.21 AC. ARE DISTURBED)
FLOODPLAIN +/- 18.06 AC.
WETLANDS
PROPOSED WATER MAIN
PROPOSED SANITARY MAIN
PROPOSED STORM SEWER
PROPOSED 5' SIDEWALK
STORM/RUNOFF DIRECTION
FP
NOTES:
1. TWO (2) FOOT CONTOUR INTERVAL SHOWN ON THIS PLAN FROM TOPOGRAPHIC
MAPPING PREPARED BY MRA, SEPTEMBER 2021.
2. BOUNDARY INFORMATION PER BOUNDARY SURVEY PREPARED BY DEWBERRY,
SEPTEMBER 2020.
3. ALL PUBLIC AND PRIVATE ROADS TO BE CONSTRUCTED PER VDOT STANDARDS.
4. ALL STREETS TO BE PRIVATE PER PROFFERS. ALL PRIVATE STREETS TO BE APPROVED
BY BOARD OF SUPERVISORS PER COUNTY CODE.
5. ALL PROPOSED UTILITIES ARE TO BE PLACED UNDERGROUND WITH THE EXCEPTION OF
THE OVERHEAD POWER LINE.
6. STORMWATER MANAGEMENT & BEST MANAGEMENT PRACTICE (SWM/BMP) CONCEPT
SHOWN FOR SCHEMATIC PURPOSES AND IS SUBJECT TO CHANGE WITH FINAL
ENGINEERING AND DESIGN PLAN SUBMISSION.
7. UTILITY LOCATIONS (STORM, SANITARY SEWER AND WATER) ARE SHOWN FOR
SCHEMATIC PURPOSES AND ARE SUBJECT TO CHANGE WITH FINAL ENGINEERING AND
DESIGN PLAN SUBMISSION.
8. THE PROPOSED SANITARY SEWER SYSTEM WILL FLOW TO THE ON-SITE PUMP STATION
TO BE PUMPED TO THE EXISTING FORCE MAIN. THIS EXISTING SANITARY SEWER
SYSTEM IS PART OF THE FREDERICK WATER SANITARY SEWER SYSTEM.
9. THE PROPOSED WATER DISTRIBUTION SYSTEM WILL CONNECT TO THE EXISTING WATER
DISTRIBUTION SYSTEMS WEST OF THE PROJECT SITE AND NEAR MERRIMANS LANE. THE
EXISTING WATER DISTRIBUTION SYSTEM IS PART OF THE FREDERICK WATER WATER
SYSTEM. THE WATER MAIN WITHIN THE DEVELOPMENT WILL BE 8" DIAMETER. THE
WATER MAIN SIZE FOR THE CONNECTION WILL BE DETERMINED WITH FINAL
ENGINEERING.
10. ELECTRIC, GAS, AND COMMUNICATION UTILITIES WILL BE COORDINATED DURING FINAL
ENGINEERING PRIOR TO CONSTRUCTION.
11. NO HISTORICAL STRUCTURES OR SITES ARE KNOWN TO EXISTING WITHIN THE PROJECT
LIMITS SHOWN ON THIS PLAN.
12. DSA AREA OR WETLAND DELINEATION SHOWN ON THIS PLAN PROVIDED BY OTHERS.
13. OPEN SPACE SHOWN HEREON IS APPROXIMATE AND SUBJECT TO MODIFICATION WITH
FINAL ENGINEERING AND DESIGN PLAN SUBMISSION.
14.ALL SIGNAGE WILL CONFORM TO FREDERICK COUNTY ZONING ORDINANCE §165-201.06
15.ALL LIGHTING WILL CONFORM TO FREDERICK COUNTY ZONING ORDINANCE §165-201.07
16. ALL LANDSCAPING WILL CONFORM TO FREDERICK COUNTY ZONING ORDINANCE
§165-203.01.
17. NO BLASTING WITHIN 300 FEET OF CITY OF WINCHESTER UTILITY LINES.
Drawn By
Plan Number
Checked By
Designed By
File Number
PRE-172
Sheet
Scale
Date
10OfWILLOW RUNMASTER DEVELOPMENT PLANFrederick County, VirginiaCOUNTY REVISIONS
DATENO.DESCRIPTION BY DewberryEngineers Inc.13575 HEATHCOTE BLVD.SUITE 130GAINESVILLE, VA 20155-6693PHONE: 703.468.2211FAX: 703.468.2212MDP #06-22
6/30/2021
6
1" = 100'
AD
ZTENVIRONMENTAL ANDUTILITIES PLANLEGEND
PROPERTY BOUNDARY;
MDP BOUNDARY
STEEP SLOPES (>35%) =+/-0.83 AC.
(+/- 0.21 AC. ARE DISTURBED)
FLOODPLAIN +/- 18.06 AC.
WETLANDS
PROPOSED WATER MAIN
PROPOSED SANITARY MAIN
PROPOSED STORM SEWER
PROPOSED 5' SIDEWALK
STORM/RUNOFF DIRECTION
FP
NOTES:
1. TWO (2) FOOT CONTOUR INTERVAL SHOWN ON THIS PLAN FROM TOPOGRAPHIC
MAPPING PREPARED BY MRA, SEPTEMBER 2021.
2. BOUNDARY INFORMATION PER BOUNDARY SURVEY PREPARED BY DEWBERRY,
SEPTEMBER 2020.
3. ALL PUBLIC AND PRIVATE ROADS TO BE CONSTRUCTED PER VDOT STANDARDS.
4. ALL STREETS TO BE PRIVATE PER PROFFERS. ALL PRIVATE STREETS TO BE APPROVED
BY BOARD OF SUPERVISORS PER COUNTY CODE.
5. ALL PROPOSED UTILITIES ARE TO BE PLACED UNDERGROUND WITH THE EXCEPTION OF
THE OVERHEAD POWER LINE.
6. STORMWATER MANAGEMENT & BEST MANAGEMENT PRACTICE (SWM/BMP) CONCEPT
SHOWN FOR SCHEMATIC PURPOSES AND IS SUBJECT TO CHANGE WITH FINAL
ENGINEERING AND DESIGN PLAN SUBMISSION.
7. UTILITY LOCATIONS (STORM, SANITARY SEWER AND WATER) ARE SHOWN FOR
SCHEMATIC PURPOSES AND ARE SUBJECT TO CHANGE WITH FINAL ENGINEERING AND
DESIGN PLAN SUBMISSION.
8. THE PROPOSED SANITARY SEWER SYSTEM WILL FLOW TO THE ON-SITE PUMP STATION
TO BE PUMPED TO THE EXISTING FORCE MAIN. THIS EXISTING SANITARY SEWER
SYSTEM IS PART OF THE FREDERICK WATER SANITARY SEWER SYSTEM.
9. THE PROPOSED WATER DISTRIBUTION SYSTEM WILL CONNECT TO THE EXISTING WATER
DISTRIBUTION SYSTEMS WEST OF THE PROJECT SITE AND NEAR MERRIMANS LANE. THE
EXISTING WATER DISTRIBUTION SYSTEM IS PART OF THE FREDERICK WATER WATER
SYSTEM. THE WATER MAIN WITHIN THE DEVELOPMENT WILL BE 8" DIAMETER. THE
WATER MAIN SIZE FOR THE CONNECTION WILL BE DETERMINED WITH FINAL
ENGINEERING.
10. ELECTRIC, GAS, AND COMMUNICATION UTILITIES WILL BE COORDINATED DURING FINAL
ENGINEERING PRIOR TO CONSTRUCTION.
11. NO HISTORICAL STRUCTURES OR SITES ARE KNOWN TO EXISTING WITHIN THE PROJECT
LIMITS SHOWN ON THIS PLAN.
12. DSA AREA OR WETLAND DELINEATION SHOWN ON THIS PLAN PROVIDED BY OTHERS.
13. OPEN SPACE SHOWN HEREON IS APPROXIMATE AND SUBJECT TO MODIFICATION WITH
FINAL ENGINEERING AND DESIGN PLAN SUBMISSION.
14.ALL SIGNAGE WILL CONFORM TO FREDERICK COUNTY ZONING ORDINANCE §165-201.06
15.ALL LIGHTING WILL CONFORM TO FREDERICK COUNTY ZONING ORDINANCE §165-201.07
16. ALL LANDSCAPING WILL CONFORM TO FREDERICK COUNTY ZONING ORDINANCE
§165-203.01.
17. NO BLASTING WITHIN 300 FEET OF CITY OF WINCHESTER UTILITY LINES.
Drawn By
Plan Number
Checked By
Designed By
File Number
PRE-172
Sheet
Scale
Date
10OfWILLOW RUNMASTER DEVELOPMENT PLANFrederick County, VirginiaDewberryEngineers Inc.13575 HEATHCOTE BLVD.SUITE 130GAINESVILLE, VA 20155-6693PHONE: 703.468.2211FAX: 703.468.2212MDP #06-22
6/30/2021
7
NTS
ZTBOUNDARYSURVEY
NOT TO SCALE
Drawn By
Plan Number
Checked By
Designed By
File Number
PRE-172
Sheet
Scale
Date
10OfWILLOW RUNMASTER DEVELOPMENT PLANFrederick County, VirginiaDewberryEngineers Inc.13575 HEATHCOTE BLVD.SUITE 130GAINESVILLE, VA 20155-6693PHONE: 703.468.2211FAX: 703.468.2212MDP #06-22
6/30/2021
7A
NTS
ZTBOUNDARYSURVEY
NOT TO SCALE
Drawn By
Plan Number
Checked By
Designed By
File Number
PRE-172
Sheet
Scale
Date
10OfWILLOW RUNMASTER DEVELOPMENT PLANFrederick County, VirginiaDewberryEngineers Inc.13575 HEATHCOTE BLVD.SUITE 130GAINESVILLE, VA 20155-6693PHONE: 703.468.2211FAX: 703.468.2212MDP #06-22
6/30/2021
8
N/A
AD
ZTPROFFERSTATEMENTSPROFFER STATEMENT (RZ# 02-21)
Drawn By
Plan Number
Checked By
Designed By
File Number
PRE-172
Sheet
Scale
Date
10OfWILLOW RUNMASTER DEVELOPMENT PLANFrederick County, VirginiaDewberryEngineers Inc.13575 HEATHCOTE BLVD.SUITE 130GAINESVILLE, VA 20155-6693PHONE: 703.468.2211FAX: 703.468.2212MDP #06-22
6/30/2021
9
N/A
AD
ZTPROFFERSTATEMENTSPROFFER STATEMENT (RZ# 02-21) (CONTINUED)
10
N/A
AD
ZTPROFFERSTATEMENTSDrawn By
Plan Number
Checked By
Designed By
File Number
PRE-172
Sheet
Scale
Date
10OfWILLOW RUNMASTER DEVELOPMENT PLANFrederick County, VirginiaDewberryEngineers Inc.13575 HEATHCOTE BLVD.SUITE 130GAINESVILLE, VA 20155-6693PHONE: 703.468.2211FAX: 703.468.2212MDP #06-22
6/30/2021
PROFFER STATEMENT (RZ# 02-21) (CONTINUED)