Loading...
HomeMy WebLinkAbout23-22 Site Plan Set 2BARTONSVILLE SOLAR BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602SITE DEVELOPMENT PLANS N FOR VICINITY MAP NOT TO SCALE N SITE 21-0281_CS C-1 COVER SHEET-SITE LOCATION MAP NOT TO SCALE ENGINEER CONTACT SUMMIT DESIGN & ENGINEERING SERVICES MATT HASTINGS, P.E. 606 BROAD STREET, SUITE C SOUTH BOSTON, VA 24592 (434) 579-4604 (PHONE) (434) 575-0617 (FAX) MATT.HASTINGS@SUMMITDE.NET DEVELOPER/OWNER TORCH CLEAN ENERGY 230 COURT SQUARE B102 CHARLOTTESVILLE, VA 22902 (703) 999-4280 (PHONE) CONTACT: SAM GULLAND SGULLAND@TORCHCLEANENERGY.COM Know what's below. before you dig.Call R CONTRACTOR SHALL NOTIFY "VA811" (811) OR (1-800-552-7001) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "VA811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. SURVEY CONTACT TIMMONS GROUP 20110 ASHBROOK PLACE, SUITE 100 ASHBURN, VA 20147 (703)726-1342 (PHONE) (703)726-1345 (FAX) SITE CONSTRUCTION SEQUENCE: 1.OBTAIN APPROVED SET OF CONSTRUCTION DRAWINGS. A ZONING COMPLIANCE PERMIT FROM FREDERICK COUNTY AND AN APPROVED EROSION CONTROL PLAN SHALL BE REQUIRED BEFORE THE ONSET OF ANY GRADING ACTIVITY. KEEP A COPY OF BOTH ITEMS ONSITE THROUGHOUT CONSTRUCTION. SEE PUBLIC SERVICE CONTACT THIS SHEET. CONTACT FREDERICK COUNTY ENGINEERING 1 WEEK PRIOR TO INITIATING LAND DISTURBANCE ACTIVITIES. 2.PRIOR TO CONSTRUCTION THE LIMITS OF DISTURBANCE (LOD), AS SHOWN ON THESE PLANS SHALL BE FLAGGED OFF. IN ADDITION, THE FOREST/OPEN SPACE AREAS SHALL ALSO BE FLAGGED OFF PRIOR TO CONSTRUCTION. NO DISTURBANCE SHALL TAKE PLACE IN THE FLAGGED FOREST/OPEN SPACE AREAS. 3.INSTALL TEMPORARY CONSTRUCTION ENTRANCE(S)/EXIT(S) AND MAINTAIN PER THE NOTES ON THIS SHEET AND IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL GUIDELINES. ALL CONSTRUCTION TRAFFIC MUST ENTER AND EXIT THE PROPERTY AT THIS LOCATION. 4.CLEAR ONLY AS NECESSARY TO INSTALL THE EROSION CONTROL DEVICES AS SHOWN ON THIS PLAN. INSTALL SILT FENCE AS SHOWN ON THE EROSION AND SEDIMENT CONTROL PLAN. 5.TREE PROTECTION FENCING SHALL BE INSTALLED ALONG THE ENTIRE LENGTH OF THE CLEARING/DISTURBANCE LIMITS WHERE THE LIMITS ARE ADJACENT TO EXISTING VEGETATION AND NO SILT FENCE IS REQUIRED. 6.INSTALL SWALES AND SEDIMENT BASINS/TRAPS PER PLANS. BOTH SHALL BE MATTED/LINED PER THE SWALE SCHEDULE AND NOTES ON PLANS. NO UPSLOPE DISTURBANCE SHALL OCCUR UNTIL THE BASINS/TRAPS/DITCHES ARE STABILIZED FOR EACH DRAINAGE AREA. 7.WHEN THE EROSION CONTROL DEVICES ARE STABILIZED AND VEGETATION IS ESTABLISHED, CONTACT FREDERICK COUNTY E&S DEPT FOR INSPECTION AND APPROVAL. 8.ONCE APPROVAL OF EROSION CONTROL DEVICES IS RECEIVED FROM FREDERICK COUNTY, BEGIN CLEARING AND GRUBBING VEGETATION AND DEMOLITION OF OTHER SITE ITEMS AS SHOWN IN THESE PLANS. DISPOSE OF ALL WASTE MATERIALS IN ACCORDANCE WITH THE APPROVED SOLID WASTE MANAGEMENT PLAN AND ALL APPLICABLE GUIDELINES OF FREDERICK COUNTY. 9.BEGIN CUT/FILL ACTIVITIES TO OBTAIN FINISHED GRADES AS SHOWN ON THE PLANS. 10.PREPARE A SOIL STOCKPILE/SPOIL AREA AS SHOWN ON PLANS. 11. CONTRACTOR SHALL REPOSITION SWALES AS FILL CHANGES THE GRADE AND ALTERS THE DRAINAGE AREA TO INSURE ALL RUNOFF IS CHANNELED INTO SEDIMENT TRAP. 12.TEMPORARY SEED AS CONDITIONS WARRANT THE NEED IN AREAS WITH NO CURRENT WORK. SEEDING SHALL TAKE PLACE IMMEDIATELY BUT IN NO CASE LATER THAN SEVEN (7) DAYS AFTER THAT CONSTRUCTION ACTIVITY HAS CEASED. 13.CONTINUE MAINTENANCE AND INSPECTION OF EROSION CONTROL DEVICES AFTER RUNOFF PRODUCING STORM EVENTS. NO DISTURBED AREA IS TO BE LEFT WITHOUT PROTECTIVE COVER (MULCH OR STRAW / TACK) AFTER COMPLETION OF CONSTRUCTION OR DEVELOPMENT ACTIVITIES PER THE TIME FRAMES ESTABLISHED IN THE STABILIZATION CHART IN THESE PLANS. DURING CONSTRUCTION OR DEVELOPMENT ACTIVITIES, ANY DISTURBED AREAS SHALL BE PROTECTED AND STABILIZED ACCORDING TO THE STABILIZATION TIMEFRAME CHART. DISTURBED AREAS FOR ANY PORTION OF THE SITE SHALL BE STABILIZED WITHIN 7 DAYS UPON COMPLETION OF CONSTRUCTION OR DEVELOPMENT ACTIVITIES IN THAT AREA. 14.INSTALL PERMANENT ACCESS ROADS AND FENCE AS CUT FILL ACTIVITIES PROMOTE. 15.UPON ACHIEVING ROUGH GRADE OF FINISHED ELEVATIONS AND ALL NECESSARY GRADING ACTIVITIES, APPLY TOPSOIL A MINIMUM OF 4" THICK TO ALL AREAS REQUIRING PERMANENT VEGETATATION. 16.APPLY TEMPORARY & PERMANENT SEEDING & FERTILIZER TO ALL FINISHED AREAS PER THE DETAILS IN THIS PLAN SET. 17.INSTALL PILES/POSTS FOR EACH TRACKER PANEL ROW. 18.INSTALL PANELS, WIRING, INVERTERS AND MISC ELECTRICAL IN ACCORDANCE WITH ELECTRICAL PLANS (BY OTHERS). 19.NO SEDIMENT CONTROL MEASURES ARE TO BE REMOVED WITHOUT APPROVAL OF FREDERICK COUNTY. 20.RE-APPLY PERMANENT SEEDING AND FERTILIZER TO ALL FINISHED AREAS DESTROYED BY ARRAY INSTALLATION. 21.APPLY BLANKET MATTING ON ALL SLOPES 3:1 OR GREATER AND SWALES. MAT SLOPES IN SUMMER AND WINTER. GRADED SLOPES AND FILLS SHALL BE PROTECTED WITH A ROLLED EROSION CONTROL PRODUCT IF COMPLETED OUTSIDE OPTIMUM GERMINATION SEASONS, WHEN UNFAVORABLE WEATHER CONDITION PREVENT ESTABLISHMENT OF VEGETATED GROUND COVER. WHEN SITE IS FULLY STABILIZED CONTACT FREDERICK COUNTY PRIOR TO CONVERSION OF SEDIMENT BASINS/TRAPS TO PERMANENT STORMWATER FACILITIES. SEDIMENT BASINS/TRAPS SHALL ONLY BE CONVERTED ONCE UPSLOPE AREA IS AT LEAST 95% ESTABLISHED WITH PERMANENT VEGETATION. 22.CONVERT SEDIMENT BASINS/TRAPS TO PERMANENT STORMWATER DETENTION BASINS (SEE DETAIL SHEETS), GRADE SWALES TO FINAL GRADING CONDITION AND APPLY FINAL SEEDING, FERTILIZER, AND MATTING. THERE ARE DETAIL SHEETS FOR EACH BASIN/TRAP BEING INSTALLED AND A MATCHING DETAIL SHEET FOR THE CONVERSION/PERMANENT CONDITION. 23.REMOVE ALL TEMPORARY EROSION CONTROL MEASURES, INCLUDING SILT FENCE, INLET PROTECTION & TEMPORARY DIVERSIONS, FINE GRADE, PERMANENTLY SEED AND STABILIZE AREAS DISTURBED FROM REMOVAL OF DEVICES AS NEEDED. 24.WHEN THE SITE IS FULLY STABILIZED, AND PERMANENT VEGETATION IS ESTABLISHED, CONTACT ENGINEER AND FREDERICK COUNTY. ENGINEER WILL INSPECT AS-BUILT CONDITIONS FOR COMPLIANCE WITH DESIGN PRIOR TO SUBMITTING NOTICE OF TERMINATION TO VIRGINIA DEQ. 25.GIVEN THE SIZE OF THIS PROJECT IT IS EXPECTED THAT SOME AREAS WILL BE STARTED AND COMPLETED PRIOR TO OTHERS. THE ENTIRE SEQUENCE ABOVE SHALL BE FOLLOWED FOR EACH DRAINAGE AREA OR PHASE OF THE PROJECT. SET 2 OF 2 (SITE/PERMANENT FOCUS) GENERAL CONTRACTOR MYR ENERGY SERVICES 12150 E 112TH AVE HENDERSON, CO 80640 (616) 215-2843 (PHONE) CONTACT: JESSE JACKSON JMJACKSON@MYRGROUP.COM C-1COVER SHEET SHEET INDEX SITE & GRADING PLAN SITE DETAILS C-4.0 - C-4.60 STORMWATER DETAILS UTILITY DETAILS D-5 - D5LL D-7 D-6 PREDEVELOPMENT DRAINAGE AREAS C-5.0 - C-5.3 POST DEVELOPMENT DRAINAGE AREAS C-6.0 - C-6.3 PREDEVELOPMENT LAND COVER C-7.0 - C-7.4 POST DEVELOPMENT LAND COVER C-8.0 - C-8.4 WATER QUALITY DESIGNATIONS C-9.0 - C-9.4 LANDSCAPING DETAILS D-8 WATER QUANTITY SUMMARY C-10.1 VDOT DETAILS D-9 - D-10 VDOT NOTES: 1.IF DETAILS ARE OVERLOOKED DURING VDOT PLAN REVIEW OR CONDITIONS IN THE FIELD EXIST SUCH THAT ADDITIONAL MEASURES ARE WARRANTED, SUCH MEASURES SHALL BE COMPLETED TO THE SATISFACTION OF THE DEPARTMENT. 2.MATERIALS USED AND METHODS OF CONSTRUCTION SHALL ADHERE TO THE CURRENT OBSERVED VDOT ROAD AND BRIDGE SPECIFICATIONS, ROAD AND BRIDGE STANDARDS, MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES, AND LAND USE PERMIT SPECIAL PROVISIONS. 3.A PRECONSTRUCTION CONFERENCE SHALL BE HELP BY THE ENGINEER OR DEVELOPER WITH ATTENDANCE OF THE CONTRACTOR, VARIOUS COUNTY AGENCIES, UTILITY COMPANIES, AND VDOT PRIOR TO INITIATION OF WORK. 4.ALL DRAINAGE IN VDOT RIGHT OF WAY SHALL BE CARRIED WITHIN THE RIGHT OF WAY IN DITCH LINES OR GUTTERS TO A PIPE OR DRAINAGE EASEMENT. 5.ANY CONSTRUCTION RELATED CHANGES TO THE APPROVED PLAN MUST COME THROUGH THE DESIGN ENGINEER TO VDOT FOR APPROVAL. PLEASE ALLOW A MINIMUM OF 5 BUSINESS DAYS FOR VDOT REVIEW. 6.A LAND USE PERMIT SHALL BE OBTAINED BEFORE ANY WORK IS PERFORMED ON THE STATE'S RIGHT OF WAY. THE PERMIT IS ISSUED BY THE EDINBURG OFFICE AND MAY REQUIRE APPLICATION FEES, THE SALARY & EXPENSES OF A STATE ASSIGNED INSPECTOR, AND SURETY BOND COVERAGE. PUBLIC SERVICE CONTACTS : GENERAL NOTES: 1.CONSTRUCTION ON THIS PROJECT SHALL BE IN ACCORDANCE WITH FREDERICK COUNTY, VIRGINIA DEQ, AND VDOT STANDARD SPECIFICATIONS. THE CONTRACTOR SHALL OBTAIN ALL APPLICABLE PERMITS AND LICENSES AND MAINTAIN COPIES OF THEM ON-SITE AT ALL TIMES DURING CONSTRUCTION. THE CONTRACTOR SHALL MAINTAIN A SET OF CONSTRUCTION DOCUMENTS, SPECIFICATIONS, AND A STORMWATER POLLUTION PREVENTION PLAN (SWPPP) ON-SITE AT ALL TIMES DURING CONSTRUCTION. 2.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REVIEW ALL OF THE DRAWINGS AND SPECIFICATIONS ASSOCIATED WITH THE PROJECT WORK SCOPE PRIOR TO THE INITIATION OF CONSTRUCTION. SHOULD THE CONTRACTOR FIND A CONFLICT WITH THE DOCUMENTS RELATIVE TO THE SPECIFICATIONS OR THE RELATIVE CODES, IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PROJECT ENGINEER OF RECORD IN WRITING PRIOR TO THE START OF CONSTRUCTION. FAILURE BY THE CONTRACTOR TO NOTIFY THE PROJECT ENGINEER SHALL CONSTITUTE ACCEPTANCE OF FULL RESPONSIBILITY BY THE CONTRACTOR TO COMPLETE THE SCOPE OF WORK AS DEFINED BY THE DRAWINGS AND IN FULL COMPLIANCE WITH LOCAL REGULATIONS AND CODES. 3.ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM WITH THESE DRAWINGS, PROJECT SPECIFICATIONS, WITH ALL CURRENT APPLICABLE CODES, AND, UNLESS OTHERWISE SPECIFIED, WITH THE LATEST REVISIONS OF THE FOLLOWING REFERENCE DOCUMENTS: A.VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT) ROAD & BRIDGE SPECIFICATIONS B.VDOT ROAD AND BRIDGE STANDARDS C.MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) D.VIRGINIA WORK AREA PROTECTION MANUAL. E.VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK (VESCH) F.VIRGINIA DEPARTMENT OF HEALTH (VDH) SPECIFICATIONS 4.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REVIEW ALL OF THE DRAWINGS AND SPECIFICATIONS ASSOCIATED WITH THE PROJECT WORK SCOPE PRIOR TO THE INITIATION OF CONSTRUCTION. SHOULD THE CONTRACTOR FIND A CONFLICT WITH THE DOCUMENTS RELATIVE TO THE SPECIFICATIONS OR THE RELATIVE CODES, IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PROJECT ENGINEER OF RECORD IN WRITING PRIOR TO THE START OF CONSTRUCTION. FAILURE BY THE CONTRACTOR TO NOTIFY THE PROJECT ENGINEER SHALL CONSTITUTE ACCEPTANCE OF FULL RESPONSIBILITY BY THE CONTRACTOR TO COMPLETE THE SCOPE OF WORK AS DEFINED BY THE DRAWINGS AND IN FULL COMPLIANCE WITH LOCAL REGULATIONS AND CODES. 5.UNDERGROUND UTILITIES MAY EXIST ON, ALONG OR WITHIN CONFLICT OF THIS PROJECT. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING VA 811 OR THE APPROPRIATE UTILITY COMPANIES 3 FULL BUSINESS DAYS PRIOR TO ANY EXCAVATION. THE CONTRACTOR MUST FIELD VERIFY ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. IN CASE OF CONFLICT, NOTIFY ENGINEER AND DO NOT CONSTRUCT. 6.ANY DAMAGE OCCURRING TO THE EXISTING SITE INFRASTRUCTURE ON THIS OR THE ADJACENT SITE DURING THE CONSTRUCTION OPERATIONS AND/OR MOBILIZATION, SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ALL EXISTING DAMAGED ITEMS INCLUDING CONCRETE AND/OR PAVEMENT SECTIONS SHALL BE RESTORED TO THEIR ORIGINAL CONDITIONS PRIOR TO PROJECT COMPLETION AT THE EXPENSE OF THE CONTRACTOR. 7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING WITH MATCHING MATERIALS ANY PAVEMENT, DRIVEWAYS. THAT MUST BE CUT OR THAT ARE DAMAGED DURING CONSTRUCTION INSIDE AND OUTSIDE OF THE LIMITS OF CONSTRUCTION. 8.THE EARTHWORK ON THIS PLAN DOES NOT NECESSARILY BALANCE IN EACH LOCATION; HOWEVER NO OFFSITE BORROW OR WASTE SHOULD MAY BE REQUIRED. 9.THE CONTRACTOR SHALL PERFORM ALL CONSTRUCTION IN ACCORDANCE WITH LOCAL CITY, COUNTY AND STATE BUILDING CODES. 10.THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE DEMOLITION OF ALL EXISTING ON SITE FACILITIES, ABOVE AND BELOW GROUND. THE CONTRACTOR IS ALSO RESPONSIBLE FOR REMOVAL OF ALL WASTE RESULTING FROM DEMOLITION, AS WELL AS GRADING AND FILLING OF ALL DEPRESSIONS TO INSURE THAT THE SITE REMAINS AESTHETICALLY ACCEPTABLE. 11.THE CONTRACTOR SHALL OBSERVE ALL REQUIRED SAFETY PRECAUTIONS IN THE PERFORMANCE OF ALL WORK IN ACCORDANCE WITH OSHA. 12.THE CONTRACTOR SHALL GRADE, SEED AND SOD OR OTHERWISE PROVIDE TEMPORARY AND PERMANENT STABILIZATION OF ALL DISTURBED AREAS, ESPECIALLY SLOPES. SEE EROSION CONTROL INSTRUCTIONS, IF APPLICABLE. 13.WORK WITHIN PUBLIC RIGHT-OF-WAYS SHALL BE IN ACCORDANCE WITH ALL STATE AND LOCAL REQUIREMENTS, NOTIFICATIONS, STANDARDS AND POLICIES. 14.ANY SUBSTITUTIONS, CHANGES, OR MODIFICATIONS SHALL BE APPROVED BY THE PROJECT ENGINEER, PLANNING DEPARTMENT STAFF, AND OWNER/DEVELOPER. 15.PRIOR TO BEGINNING CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ACQUIRING ALL PERMITS NECESSARY TO CONSTRUCTION. THE CONTRACTOR SHALL READ ALL PERMITS AND ENSURE THAT CONSTRUCTION COMPLIES WITH THE PERMITS. REQUIRED PERMITS MAY INCLUDE, BUT ARE NOT LIMITED TO: CITY/COUNTY APPROVALS/PERMITS, VDOT PERMITS, DRIVEWAY PERMITS, EROSION CONTROL PERMITS, VDEQ PERMITS, ENVIRONMENTAL PERMITS, STREAM CROSSING PERMITS, USACE/DWQ PERMITS, AND STORMWATER PERMITS. IF THE CONTRACTOR HAS QUESTIONS ABOUT PERMIT LANGUAGE, OR THE NEED FOR A PERMIT, HE MUST CONTACT THE DEVELOPER AND THE ENGINEER PRIOR TO BEGINNING CONSTRUCTION. 16.THE GRADING CONTRACTOR MUST MAINTAIN COPIES OF THE EROSION CONTROL PERMIT AND THE NPDES PERMIT ONSITE. HE MUST READ AND FOLLOW THE CONDITIONS OF THOSE PERMITS. 17.THE CONTRACTOR MUST VERIFY ALL FIELD ELEVATIONS PRIOR TO CONSTRUCTION. NOTIFY OWNER AND ENGINEER OF ANY VARIATION OF FIELD ELEVATIONS PRIOR TO CONSTRUCTING. NO FIELD CHANGES OR DEVIATIONS FROM DESIGN ARE TO BE MADE WITHOUT PRIOR APPROVAL OF THE OWNER AND NOTIFICATION TO THE ENGINEER. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR WORK HAVING TO BE REDONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF NO NOTIFICATION IS GIVEN TO THE OWNER AND ENGINEER. 18.THERE IS NO SITE LIGHTING OR SITE SIGNAGE PROPOSED WITH THIS SITE PLAN. 19.BOUNDARY AND TOPOGRAPHIC SURVEY PROVIDED BY (TIMMONS GROUP) - (703)726-1342 . WINCHESTER, VA 22602 SPRINGDALE & MARLBORO ROAD MAGISTERIAL DISTRICT: BACK CREEK & OPEQUON APPROVAL BY THE FREDERICK COUNTY ZONING ADMINISTRATOR: SITE PLAN VALID FOR FIVE (5) YEARS FROM APPROVAL DATE. __________________________________ ______________ SIGNATURE DATE APPROVAL BY THE TOWN MANAGER OF STEPHENS CITY: SITE PLAN VALID FOR FIVE (5) YEARS FROM APPROVAL DATE. _________________________________ ______________ SIGNATURE DATE FREDERICK COUNTY CUP & PARCELS: CUP #05-20: 74-A-3, 74-A-4, 74-A-6C, 74-A-20, 74-A-21, 74-A-35A, 74-A-44, 74-A-44A, 74-A-45, 74-5-1 through 74-5-52, 74-7-1-1 through 74-7-1-6, 74-7-2-7 through 74-7-2-12 CUP #11-21: PINS 73-A-104, 74-A-18, 74-A-18A, 74-A-18B, 74-A-19, 74-A-20, 85-A-1 EXISTING ZONING & USE: EXISTING ZONING: RA (RURAL AREAS), R1 (TOWN OF STEPHENS CITY) EXISTING USE: AGRICULTURAL, FORESTED, VACANT, OPEN SPACE, RESIDENTIAL, & RESIDENTIAL (PLATTED ONLY) PROPOSED USE: 172 MW +/- UTILITY-SCALE SOLAR POWER GENERATING FACILITY PROJECT AREA (LEASED AREA): +/-1260.84 AC TOTAL PARCEL AREAS: +/- 1797.2 AC DISTURBED AREA: 889.7 AC PROJECT SETBACKS: FROM CUP #05-20: 100' FROM ALL EXTERNAL ROADS AND PROPERTY LINES FROM CUP #11-21: 100' FROM ALL EXTERNAL ROADS AND PROPERTY LINES, 200' FROM ADJOINING PROPERTIES LOCATED WITHIN THE SOUTH FREDERICK AGRICULTURAL AND FORESTAL DISTRICT PARKING: 2 SPACES AT AC COLLECTOR STATION REQUIRED PER PLANNERS ADVISORY SERVICE- PARKING STANDARDS (2002) AND PER FREDERICK COUNTY PLANNING STAFF COMMENT. THE PARKING SPACES ARE SHOWN ON SHEET C-4.46 OF SET 2 OF 2. FIRE: FREDERICK COUNTY FIRE MARSHAL 1080 COVERSTONE DRIVE WINCHESTER, VA 22602 (540) 665-6350 STATE ROADWAYS:VDOT- EDINBURG RESIDENCY LLOYD INGRAM 14031 OLD VALLEY PIKE EDINBURG, VA 22824 (540)984-5600 PLANNING:FREDERICK COUNTY PLANNING 107 NORTH KENT ST WINCHESTER, VA 22601 (540)665-5651 PUBLIC WORKS:FREDERICK COUNTY PUBLIC WORKS 107 NORTH KENT ST WINCHESTER, VA 22601 (540)722-8215 STORMWATER: FREDERICK COUNTY PUBLIC WORKS & E&S 107 NORTH KENT ST WINCHESTER, VA 22601 (540)722-8214 BUILDING FREDERICK COUNTY BUILDING INSP. INSPECTIONS:107 NORTH KENT ST WINCHESTER, VA 22601 (540)665-5650 WATER FREDERICK WATER & SEWER:315 TASKER RD STEPHENS CITY, VA 22655 (540)868-1061 TOWN OF TOWN OF STEPHENS CITY STEPHENS CITY:1033 LOCUST STREET STEPHENS CITY, VA 22655 (540)869-3037 CUP #05-20 CONDITIONS: 1.ALL REVIEW AGENCY COMMENTS PROVIDED DURING THE REVIEW OF THIS APPLICATION SHALL BE COMPLIED WITH AT ALL TIMES. 2.AN ENGINEERED SITE PLAN, IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE VIII OF THE FREDERICK COUNTY ZONING ORDINANCE, SHALL BE SUBMITTED TO AND SUBJECT TO APPROVAL BY FREDERICK COUNTY PRIOR TO THE ESTABLISHMENT OF THE USE. THE SITE PLAN SHALL ADDRESS ADDITIONAL REGULATIONS FOR SPECIFIC USES OUTLINED IN §165-204.26 OF THE FREDERICK COUNTY ZONING ORDINANCE AND BE IN GENERAL CONFORMANCE WITH THE CONCEPT PLAN, INCLUDED WITH THE CUP APPLICATION, PREPARED BY GREENWAY ENGINEERING, DATED AUGUST 28, 2020. 3.BUFFERS AND SCREENING SHALL BE PROVIDED AROUND THE PERIMETER OF THE PROJECT IN GENERAL CONFORMANCE WITH QUANTITY OF THE PROPOSED PLANTINGS DEPICTED ON SHEETS 3 AND 4 OF THE CONCEPT PLAN, "LANDSCAPE BUFFER A, B, C, D, E & F ," INCLUDED WITH THE CUP APPLICATION, PREPARED BY GREENWAY ENGINEERING, DATED AUGUST 28, 2020. THE LANDSCAPE BUFFER PLANTINGS SHALL BE MAINTAINED IN GOOD HEALTH FOR THE LIFE OF THE PROJECT. LANDSCAPE PLANTINGS SHALL BE INSTALLED AT THE FIRST OPTIMAL GROWING SEASON FOLLOWING THE COMMENCEMENT OF CONSTRUCTION. 4.PRIOR TO SITE PLAN APPROVAL, THE OWNER SHALL ENTER INTO A WRITTEN AGREEMENT WITH FREDERICK COUNTY TO DECOMMISSION SOLAR ENERGY EQUIPMENT, FACILITIES, OR DEVICES PURSUANT TO THE TERMS AND CONDITIONS OF§ I 5.2-2241.2(B) OF THE CODE OF VIRGINIA. THE WRITTEN AGREEMENT SHALL BE UPDATED EVERY FIVE (5) YEARS AND IN GENERAL CONFORMANCE WITH THE EXHIBIT D: PRELIMINARY DECOMMISSIONING PLAN, INCLUDED WITH THE CUP APPLICATION, PREPARED BY TORCH CLEAN ENERGY, DATED MAY 2020. 5.BATTERIES, FOR THE PURPOSES OF MASS STORAGE OF ELECTRICITY THAT WILL EVENTUALLY BE TRANSFERRED TO THE GRID, ARE PROHIBITED AS PART OF THIS CUP. 6.THIS CONDITIONAL USE PERMIT SHALL NOT BE EFFECTIVE UNLESS AND UNTIL THE VACATIONS OF THE SPRINGDALE GLEN AND CARROLLTON ESTATES SUBDIVISIONS ARE APPROVED AND RECORDED. IN ADDITION, THE APPROVAL AND RECORDATION OF SUCH VACATIONS SHALL TAKE PLACE PRIOR TO THE APPROVAL OF ANY SITE PLAN FOR THE USE AUTHORIZED BY THIS CONDITIONAL USE PERMIT. 7.ACCESS TO THE SITE SHALL BE LIMITED TO TWO (2) ENTRANCES FROM SPRINGDALE ROAD AND ONE (I) ENTRANCE FROM PASSAGE ROAD, AND BE IN GENERAL CONFORMANCE WITH THE CONCEPT PLAN, INCLUDED WITH THE CUP APPLICATION, PREPARED BY GREENWAY ENGINEERING, DATED AUGUST 28, 2020. DELIVERY OF SOLAR ARRAY PANEL CONSTRUCTION MATERIALS WILL OCCUR AT THE SITE ACCESS ENTRANCE OFF OF PASSAGE ROAD IDENTIFIED AS DEER LANE ON SHEET 4 OF THE CONCEPT PLAN. SOLAR ARRAY PANEL MATERIALS DELIVERY LAYDOWN AREA WILL BE LIMITED TO TAX PARCEL 74-A-44A (CARBAUGH PROPERTY). 8.PILE-DRIVING OF POLES FOR SOLAR ARRAYS DURING CONSTRUCTION SHALL BE LIMITED TO 7:00 A.M. TO 5:00 P.M. MONDAY THROUGH FRIDAY. ALL OTHER CONSTRUCTION ACTIVITIES ARE PERMITTED 7:00 A.M. TO 7:00 P.M. MONDAY THROUGH FRIDAY AND 7:00 A.M. TO 5:00 P.M. ON SATURDAY. NO CONSTRUCTION ACTIVITIES ARE PERMITTED ON SUNDAYS. THE OWNER SHALL NOTIFY ALL RESIDENCES WITHIN 1,000-FEET OF THE PROJECT REGARDING THE COMMENCEMENT OF PILE-DRIVING ACTIVITIES FOURTEEN DAYS OR MORE PRIOR TO THE START OF SUCH ACTIVITIES. A COPY OF THE NOTIFICATION SHALL ALSO BE PROVIDED TO THE FREDERICK COUNTY DEPARTMENT OF PLANNING & DEVELOPMENT DURING THE SAME FOURTEEN DAY OR MORE PERIOD. 9.THE LOCATION OF INVERTERS SERVING THE SOLAR PROJECT SHALL BE AT LEAST 450-FEET FROM ALL ADJACENT RESIDENCIES. 10.SUBDIVISION, FOR RESIDENTIAL DEVELOPMENT, OF TAX PARCELS 74-A-3, 74-A-4, 74-A-6C, OR OF THE AREA CURRENTLY CONSTITUTING THE SPRINGDALE GLEN AND CARROLLTON ESTATES SUBDIVISIONS SHALL BE PROHIBITED DURING SUCH TIME AS SOLAR POWER GENERATING EQUIPMENT IS INSTALLED ON SAID PARCELS. 11.THE USE OF ARTIFICIAL HERBICIDES IS PROHIBITED FOR WEED ABATEMENT AND CONTROL MEASURES. 12.ANY EXPANSION OR MODIFICATION OF THIS LAND USE WILL REQUIRE THE APPROVAL OF A NEW CUP. CUP #11-21 CONDITIONS: 1.ALL REVIEW AGENCY COMMENTS PROVIDED DURING THE REVIEW OF THIS APPLICATION SHALL BE COMPLIED WITH AT ALL TIMES. 2.AN ENGINEERED SITE PLAN, IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE VIII OF THE FREDRICK COUNTY ZONING ORDINANCE, SHALL BE SUBMITTED TO AND SUBJECT TO APPROVAL BY FREDERICK COUNTY PRIOR TO THE ESTABLISHMENT OF THE USE. THE SITE PLAN SHALL ADDRESS ADDITIONAL REGULATIONS FOR SPECIFIC USES OUTLINED IN §165-204.26 OF THE FREDERICK COUNTY ZONING ORDINANCE AND BE IN GENERAL CONFORMANCE WITH THE PHASE II EXPANSION AREA CONCEPT PLAN, INCLUDED WITH THE CUP APPLICATION, PREPARED BY GREENWAY ENGINEERING, DATED OCTOBER 26, 2021. 3.PURSUANT TO CODE OF VIRGINIA F §15.2-2241.2(B), THE OWNER SHALL COMPLY WITH THE EXHIBIT D: EXPANSION AREA DECOMMISSIONING PLAN, INCLUDED WITH THE CUP APPLICATION, PREPARED BY TORCH CLEAN ENERGY, DATED SEPTEMBER 2021, AND SHALL UPDATE THE EXPANSION AREA DECOMMISSIONING PLAN EVERY FIVE (5) YEARS. 4.WITHIN THIRTY (30) DAYS AFTER THE COMMERCIAL OPERATION DATE, BARTONSVILLE ENERGY FACILITY II, LLC SHALL MAKE A ONE-TIME PAYMENT TO THE COUNTY IN THE AMOUNT OF SEVEN HUNDRED FIFTY THOUSAND DOLLARS ($750,000.00) (THE “PAYMENT”). THESE CONDITIONS SHALL BE MEMORIALIZED IN A SOLAR SITING AGREEMENT WITH FREDERICK COUNTY, ATTACHED AS SCHEDULE C-1 OF THESE CONDITIONS, PURSUANT TO CODE OF VIRGINIA SECTION 15.2-2316.6 ET SEQ. 5.BATTERIES, FOR THE PURPOSES OF MASS STORAGE OF ELECTRICITY THAT WILL EVENTUALLY BE TRANSFERRED TO THE GRID, ARE PROHIBITED AS PART OF THIS CUP. 6.ACCESS TO THE SITE SHALL BE LIMITED TO ONE (1) ENTRANCE FROM MARLBORO ROAD (ROUTE 631) VIA STRODE MCLEOD LANE TO BE USED FOR CONSTRUCTION AND GENERAL SITE ACCESS AND THE ENTRANCE CONFIGURATION SHALL BE IN GENERAL CONFORMANCE WITH THE PHASE II EXPANSION AREA CONCEPT PLAN, INCLUDED WITH THE CUP APPLICATION, PREPARED BY GREENWAY ENGINEERING, DATED OCTOBER 26, 2021. DELIVERY OF SOLAR ARRAY PANEL CONSTRUCTION MATERIALS WILL OCCUR AT THE SITE ACCESS ENTRANCE OFF OF MARLBORO ROAD USING STRODE MCLEOD LANE ON SHEET 3 OF THE CONCEPT PLAN. SOLAR ARRAY PANEL MATERIALS DELIVERY LAYDOWN AREA WILL BE RESTRICTED TO TAX PARCEL 74-A-18. 7.A PHASE 1 ARCHEOLOGICAL SURVEY WILL BE COMPLETED AND SUBMITTED TO THE DEPARTMENT OF PLANNING & DEVELOPMENT PRIOR TO SITE PLAN APPROVAL. THIS SURVEY SHOULD DOCUMENT THE COLLECTION OF HISTORIC STRUCTURES ON AND AROUND THIS DEVELOPMENT AND DETERMINE IF THIS AREA WOULD QUALIFY AS A RURAL HISTORIC DISTRICT. 8.PILE-DRIVING OF POLES FOR SOLAR ARRAYS DURING CONSTRUCTION SHALL BE LIMITED TO 8:00 A.M. TO 5:00 P.M. MONDAY THROUGH FRIDAY. ALL OTHER CONSTRUCTION ACTIVITIES ARE PERMITTED 7:00 A.M. TO 7:00 P.M. MONDAY THROUGH FRIDAY AND 7:00 A.M. TO 5:00 P.M. ON SATURDAY. NO CONSTRUCTION ACTIVITIES ARE PERMITTED ON SUNDAYS. THE APPLICANT SHALL PROVIDE AT LEAST TWO (2) WEEKS WRITTEN NOTICE TO ADJOINING PROPERTY OWNERS OF THE START OF ANY PILE-DRIVING ACTIVITIES. A COPY OF THE WRITTEN NOTICE SHALL ALSO BE PROVIDED TO THE DEPARTMENT OF PLANNING AND DEVELOPMENT. 9.ANY EXPANSION OR MODIFICATION OF THIS LAND USE WILL REQUIRE THE APPROVAL OF A NEW CUP. SITE PLAN #23-22 TOWN OF STEPHENS CITY LIMITS (DASHED) TOWN OF STEPHENS CITY LIMITS (DASHED) 9.4'4001798.41NAIL FND4005798.77POST WOOD1050003838.68LF--RTK1050002826.39LF--RTK1050014854.95LF--RTK1050012822.80LF--RTK1050008801.15LF IN RROW1050021805.95LF not here1050030805.93LF1050037743.73LF1050038743.47LF1050045827.32LF5003772.26LF LAID OUT--RTK1050079828.31LF--RTK22.1'3.6'5.4'4.4'21.7'2.1'4.9'5.6'4.9'10.0'27.4'9.3'1.2'5.0'5.2'4.2'4.7'5.3'14.6'32.1'29.5'9.0'9.0'9.4'10.7'8.6'10.7'8.6'WW WWWWWW WRR5009769.11LF GONEOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHP1061826.56MB 2961087826.88MB 1216T1127760.90TPT1128761.91TP1129794.18TPT1131790.09TPLAYDOWN LAYDOWNLAYDOWN0.00%WWWWW WWINV 9INV 10INV 11INV 14INV 15INV 12INV 13INV 16INV 17INV 20INV 3INV 4INV 5INV 6INV 34INV 35INV 29INV 30INV 31INV 36INV 37INV 32INV 33INV 38INV 39INV40INV 41DCACINV 21INV 25INV 24INV 22INV 8INV 7INV 27INV 28INV 26INV 23INV 1INV 2INV 19INV 18329'20'329'15'329'15'329'220'32'20'329'73'20'INV. IN = 781.50'INV. OUT = 780.50'100' - 18" HDPE @ 1.00%100'SETBACK329'15'329'20'15'329'15'329'20'20'20'R35'R35'100' SETBAC K EXISTINGWETLAND329'15'20'329'15'329'19'329'15'329'15'19'220'329'19'220'15'329'20'100' SETBACK EXISTINGWETLAND72'20'R40'R40'329'24'329'20'20'15'329'15'329'15'20'329'20'R15'R15'R48'220'19'220'100'SETBACK100'SETBACK100'SETBACK80'15'15'22'22'20'53'20'33'15'329'15'329'20'19'220'329'15'329'160'25'100'SETBACK100'SETBACKPROPOSED LIMITOF DISTURBANCE329'15'329'329'R100'R100'INV. OUT = 794.00'INV. IN = 796.00'70' - 15" HDPE @ 2.86%PROJECT AREA200'SETBACK15'CONTRACTOR SHALLINSTALL 50' WIDE, 25'LONG, 18" DEEP VDOTCLASS 1 RIP RAP BELOWOUTFALL OF CONCRETEDRIVEWAY FLOW SECTION.330'15'330'79'15'330'15'330'15'330'15'330'15'330'15'330'15'330'100'SETBACK 100'SETBACKPROJECT AREA100'SETBACK33'20'15'15'100'SETBACK200'SETBACK20'PROPOSED LIMITOF DISTURBANCE7' GAME FENCEPROJECT AREAEXISTING WETLANDPROPOSEDARRAYS (TYP.)PROJECT AREA200'SETBACK100'SETBACKPROPOSED LIMITOF DISTURBANCEPROJECT AREA200' SET BACK 100'SETBACK15'100'SETBACK15'7' GAME FENCE7' GAME FENCE220'20'LANDSCAPE BUFFER "B1"330'20'220'15'20'PROPOSED LIMITOF DISTURBANCEPROJECT AREA100' SETBACK7' GAME FENCEPROPOSED LIMITOF DISTURBANCEPROJECT AREAPROPOSEDARRAYS (TYP.)PROPOSED LIMITOF DISTURBANCEPROJECT AREA7' GAMEFENCEPROPOSEDARRAYS (TYP.)LEASED AREA100'SETBACK22'100'SETBACK15'7' GAME FENCEPROJECT AREAGRAVEL ACCESS ROAD330'15'19'221'R450'INVERTER SETBACK100'SETBACK7' GAME FENCEPROPOSED LIMITOF DISTURBANCE15'PROJECT AREA15'330'20'PROPOSED LIMITOF DISTURBANCE330'221'20'20'PROPOSED LIMITOF DISTURBANCE22'PROPOSEDARRAYS (TYP.)100'SETBACKGRAVEL ACCESS ROADR15'R48'20'7' GAME FENCEPROPOSED LIMITOF DISTURBANCEGRAVEL ACCESS ROAD7' GAME FENCEPROPOSED LIMITOF DISTURBANCEPROJECT AREA100'SETBACKPROPOSEDARRAYS (TYP.)22'20'R30'R40'7' GAME FENCE100'SETBACK100'SETBACK7' GAME FENCEPROPOSED LIMITOF DISTURBANCE22'GRAVEL ACCESSROADPROJECT AREAPROPOSED LIMITOF DISTURBANCEPROPOSEDARRAYS (TYP.)PROPOSEDARRAYS (TYP.)PROJECT AREAPROPOSED LIMITOF DISTURBANCE7' GAME FENCE100'SETBACK60'100'SETBACK7' GAME FENCEPROPOSED LIMITOF DISTURBANCE450'INVERTER SETBACKPROPOSEDARRAYS (TYP.)GRAVEL ACCESS ROA D 7' GAME FENCE100'SETBACK60'450' INVERTER SETBACKPROPOSEDARRAYS (TYP.)22'75'22'GRAVEL ACCESSROAD7' GAME FENCEPROPOSED LIMITOF DISTURBANCE100'SETBACKPROJECT AREAPROPOSEDARRAYS (TYP.)100'SETBACK450' INVERTERSETBACK60'7' CHAINLINK FENCEPROPOSED LIMITOF DISTURBANCEPROJECT AREAPROPOSEDARRAYS (TYP.)7' GAME FENCEPROPOSED LIMITOF DISTURBANCEPROJECT AREA100'SETBACKPROJECT AREAPROPOSED LIMITOF DISTURBANCE7' GAME FENCEPROPOSED LIMITOF DISTURBANCEPROJECT AREATREES TO BE PROTECTEDPROPOSED LIMITOF DISTURBANCEPROPOSED LIMITOF DISTURBANCE40' - 15" HDPE @ 2.5%INV OUT- 787INV IN- 7884.14.24.34.44.54.64.74.84.94.104.114.124.134.144.154.164.174.184.224.214.204.194.234.244.254.264.304.294.284.274.314.324.334.364.354.344.374.384.394.404.414.464.454.444.434.424.474.484.494.504.514.554.544.534.524.564.574.584.604.591%76 1 76 4 767770772774 WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 750 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.0 OVERALL SITE & GRADING PLANUTILITY NOTES: 1.ALL NEW UTILITIES SHALL BE LOCATED UNDERGROUND. IF ALLOWED BY LOCAL CODES. 2.ALL PUBLIC UTILITIES AND CONNECTIONS TO PUBLIC UTILITIES SHALL CONFORM TO THE HCSA STANDARDS AND SPECIFICATIONS. NONE ARE PROPOSED. 3.THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ANY PERMITS NECESSARY FOR CONSTRUCTION. 4.THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF THE LOCATION AND/OR RELOCATION OF ALL EXISTING UTILITIES WITH THE APPROPRIATE UTILITY, AGENCY OR COMPANY. 5.THE CONTRACTOR SHALL COORDINATE ALL UTILITY CONNECTIONS AND DISTURBANCES WITH EXISTING USERS AND FREDERICK COUNTY, SO THAT ANY SERVICE INTERRUPTIONS ARE MINIMAL SITE NOTES: 1.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH FREDERICK COUNTY STANDARDS AND SPECIFICATIONS. 2.PARKING AREAS AND DRIVEWAYS SHALL BE GRAVEL AS SHOWN UNLESS CONCRETE OR ASPHALT IS SPECIFIED. 3.CONTRACTOR SHALL MAINTAIN ANY EXISTING ACCESSES TO ADJACENT RESIDENCES, BUSINESSES AND PROPERTIES AT ALL TIMES. 4.CONTRACTOR IS RESPONSIBLE FOR OBTAINING ANY PERMITS NECESSARY FOR CONSTRUCTION. GRADING / DRAINAGE NOTES 1.THIS PROPERTY IS WITHIN THE CONOCOCHEAGE-OPEQUON AND SHENANDOAH WATERSHED. 2.ALL PIPE AND STRUCTURES TO BE INSTALLED ON-SITE AND IN THE RIGHTS OF WAY SHALL MEET OR EXCEED THE VDOT SPECIFICATIONS. 4.ALL ON-SITE PIPE SHALL BE INSTALLED MEETING COVER, BACKFILL AND BEDDING REQUIREMENTS PER THE MANUFACTURER'S RECOMMENDATIONS. 5.VDOT PRE-CAST DRAINAGE STRUCTURES / MANHOLES SHALL BE USED. ANY DEVIATION FROM THE SPECIFIED STRUCTURES SHALL BE APPROVED BY ENGINEER PRIOR TO INSTALLATION AND SHALL MAINTAIN COMPLIANCE WITH ALL CORRESPONDING VDOT MATERIAL, DRAWING & DETAILED SPECIFICATIONS. 6.ALL EXISTING STORM SEWER PIPES, DROP INLETS, AND CURB INLETS BEING UTILIZED BY A PART OF THE DRAINAGE SYSTEM SHALL BE CLEANED OF ERODED MATERIAL AT ALL STAGES OF CONSTRUCTION, AS DIRECTED BY THE ENGINEER. THE COST INCIDENTAL TO THIS IS TO BE INCLUDED IN THE CONTRACT PRICE FOR THE OTHER DRAINAGE ITEMS. ALL STORM SEWER PIPES, MANHOLES, AND CURB INLETS SHALL BE CLEANED OF DEBRIS AND ERODED MATERIALS AT THE LAST STAGES OF CONSTRUCTION 7.STORM SEWER PIPES AS SHOWN ON THE PLANS ARE MEASURED FROM THE CENTERLINE OF EACH STRUCTURE AND INVERT ELEVATIONS ARE ESTABLISHED BASED ON THIS CENTER LINE DISTANCE. LENGTH CALL OUTS FOR PIPES WITH FLARED END SECTIONS WILL BE MEASURED TO THE JOINT. CONTRACTOR SHALL LOCATE ALL END SECTIONS TO MATCH THE BANK SLOPE AND THE PIPE SLOPE SHALL BE ADJUSTED AS NECESSARY. 8.BOOT CONNECTIONS SHALL BE PROVIDED FOR ALL PLASTIC PIPES THAT TIE INTO A CONCRETE STRUCTURE. 9.PROPOSED CONTOUR LINES REPRESENT FINISHED GRADE ELEVATIONS. CONTOUR LINES MAY BE ADJUSTED AT THEIR BEGINNING, ENDING AND AT STRUCTURES AS DIRECTED BY THE ENGINEER IN ORDER TO PROVIDE A PROPER TIE-IN. 10.MONITOR, MAINTAIN, MOVE AND/OR ADD SILT FENCE, SILT FENCE OUTLETS, AS NEEDED BASED ON FIELD AND RUNOFF CONDITIONS AND AS DIRECTED BY THE ENGINEER AND/OR COUNTY REPRESENTATIVE. 10.A SEDIMENTATION AND EROSION CONTROL PLAN MUST BE SUBMITTED TO FREDERICK COUNTY AND APPROVED PRIOR TO MOVING FORWARD WITH CONSTRUCTION. 11.IF AN OFFSITE SOIL SPOIL OR BORROW SITE IS UTILIZED, THEN THE DISTURBED AREA FOR THE SPOIL/BORROW SITE MUST BE INCLUDED IN THE LAND-DISTURBANCE PLAN AND PERMIT UNLESS THE SPOIL/BORROW SITE ALREADY HAS A LAND-DISTURBING PERMIT. 12.SEE STORMWATER CALCULATIONS PACKET FOR DETAILED NUTRIENT AND PEAK FLOW CALCULATIONS. 13.ALL GRASS SLOPES WHICH EXCEED 3:1 (H:V) SHALL UTILIZE NORTH AMERICAN GREEN (NAG) CONSTRUCTION PRODUCTS TURF REINFORCEMENT MATS SC150 OR APPROVED EQUAL UNLESS OTHERWISE SPECIFIED ON PLANS. MATS SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS AND STANDARDS. CONTRACTOR SHALL COORDINATE INSTALLATION INSPECTION WITH MANUFACTURER. 16.ALL FILL SHALL AT A MINIMUM MEET 95% STANDARD PROCTOR DENSITY PER ASTM D 1557. ALL OTHER PORTIONS OF EARTHWORK AND GRADING AT A MINIMUM SHALL ADHERE TO THIS CODE SECTION. BUT IN NO WAY SHALL SUPERCEDE THE SITE SPECIFIC GEO-TECHINICAL RECOMMENDATIONS. IT IS HIGHLY RECOMMENDED THAT ADDITIONAL GEO-TECHINCAL EVALUATIONS BE DONE OF THE BUILDING PAD AREAS DUE TO UNKNOWN BURIED CONSTRUCTION DEBRIS. 17.GENERAL CONTRACTOR SHALL NOTIFY ALL UTILITY COMPANIES HAVING UNDERGROUND UTILITIES ON SITE OR IN RIGHT-OF-WAY PRIOR TO EXCAVATION. CONTRACTOR SHALL CONTACT UTILITY LOCATING COMPANY AND LOCATE ALL UTILITIES PRIOR TO GRADING START. SEE EXISTING CONDITIONS SHEET FOR UTILITY CONTACT INFORMATION. 18.SITE GRADING SHALL NOT PROCEED UNTIL EROSION CONTROL MEASURES HAVE BEEN INSTALLED AND APPROVED BY APPLICABLE AUTHORITY. 19.ALL ELEVATIONS ARE IN REFERENCE TO THE BENCHMARK, AND THIS MUST BE VERIFIED AND LOCATED BY THE GENERAL CONTRACTOR PRIOR TO GROUND BREAKING. 20.CONTRACTOR SHALL ENSURE POSITIVE DRAINAGE SO THAT RUNOFF WILL DRAIN BY GRAVITY FLOW TO NEW OR EXISTING DRAINAGE INLETS OR SHEET FLOW OVERLAND. 21.THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE GENERAL V.S.M.P. PERMIT FOR STORMWATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES. 22.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING CONDITIONS OR BETTER. 23.FINAL GRADES SHALL BE WITHIN ±0.1' OF THE PROPOSED FINISHED GRADES SHOWN ON THE PLAN. TOWN OF STEPHENS CITY LIMITS (DASHED) TOWN OF STEPHENS CITY LIMITS (DASHED) TOWN OF STEPHENS CITY LIMITS (DASHED) STR O D E M C L E O D L N CSX R A I L R O A D C S X R A I L R O A D MARLBORO RDMARLBORO RDPAS S A G E R DPASSAGE RDSPRIN G DALE RD SPRINGDALE RDMIDDLE RD4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.1 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.4 MATCHLINE - SEE SHEET C-4.21 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLD LD LD LD LD LDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD 835 840 845 850 85 5 834 836 837 838 839 841 842 843 844 846 847 84 8 84 9 851 852 85 3 85 4 85 6 857 858 859 85 0 85 5 8468 4 78488 4 9 851 852 85 3 85 4 85 6 7' GAME FENCE 20'329'PROJECT AREA PROPOSED LIMIT OF DISTURBANCE 100'SETBACKPROPOSED ARRAYS (TYP.) WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.2 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.5 MATCHLINE - SEE SHEET C-4.3MATCHLINE - SEE SHEET C-4.14.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLD848847846845844843842841840839838837838839840841841840839838837836835834833832831843 842 841 841 840 8 5 0 85 5 860 8468 4 78488 4 9 851 852 85 3 85 4 85 6 85 7 858 859 861 20'329'7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE PROJECT AREA 100'SETBACKDETENTION POND 2-1A (SEE SHEET D-5LL) PROPOSED ARRAYS (TYP.) 100' SETB A C K WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602--- C-4.3 SITE & GRADING PLAN-1 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.6MATCHLINE - SEE SHEET C-4.24.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LANDSCAPE BUFFER "A1" 810815820825830 809811812 813814816817818819821822823824826827828 82915'PROJECT AREA 100' SETBACK PROPOSED LIMIT OF DISTURBANCE 7' GAME FENCE PROPOSED ARRAYS (TYP.) 20'329'15'EXISTING VEGETATION/TREE LINE WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.4 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.8 MATCHLINE - SEE SHEET C-4.51 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.1 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDINV 3 LANDSCAPE BUFFER "A1"822821820819818817816815814819 819818817816815814 818 817 816 815 81482282182081981882382382482582682782882882782682582482382382482582682782882 8 82 8 8458468 4 7 825830835840845 82382482682782882983183283383483683783883984184284384484684782583083584084582182282382482682782882983183283383483683783883984184284384482082583082182282382482682782882983183283383415'20 ' 20'329'15'20'100' SETBACK DETENTION POND 1N (SEE SHEET D-5J) DETENTION POND 2A (SEE SHEET D-5LL)R40' R30'15'PROJECT AREA PROPOSED LIMIT OF DISTURBANCE 7' GAME FENCE 7' GAME FENCEPROPOSED LIMIT OF DISTURBANCE INVERTER SKID (TYP.) PROPOSED ARRAYS (TYP.)329'GRAVEL ACCESS ROAD PROPOSED ARRAYS (TYP.) 829 831 834 832 830 828 826 824 822 820 818 816 814 812 20'46'70 ' R1 5 0 '8118128147'26'WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.5 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.9 MATCHLINE - SEE SHEET C-4.61 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.2 MATCHLINE - SEE SHEET C-4.44.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLDLDLD8458468 4 7 7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE PROPOSED ARRAYS (TYP.) 100' SET B A C K PROJECT AREA WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.6 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.10 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.3 MATCHLINE - SEE SHEET C-4.54.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD INV 1 LANDSCAPE BUFFER "A1"82081881920'20'R 3 5 ' R35' INVERTER SKID (TYP.) GRAVEL ACCESS ROAD 7' GAME FENCE15'PROPOSED LIMIT OF DISTURBANCE PROJECT AREA 329'70'70'8 4 3 838 835 832 8298278 2 6 8 2 9 13' WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.7 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.11 MATCHLINE - SEE SHEET C-4.81 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LD LD LD LDLDLDLDLDLDLD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LDLDLDLDLDLD805810815802803804806807808809811812813814816 790795800 805 786 787 788789791792793794796797 798 799 801 802 803 804 806 807 808 785 784 783 782 781 780 782 782 7 8 3 7 8 4785786787788789790791792793794 795796793794795796799800801802803 803 802 801 800 799 793794795796798798796795794793792810 815820 807 808 809 811 812 813 814816817818819 DETENTION POND 1A (SEE SHEET D-5A) DETENTION POND 1B (SEE SHEET D-5B) PROPOSED ARRAYS (TYP.)329'73' 20'DITCH DA ILINV. IN = 781.50' INV. OUT = 780.50' 100' - 18" HDPE @ 1.00% PROPOSED LIMIT OF DISTURBANCE PROPOSED LIMIT OF DISTURBANCE 7' GAME FENCE 100' SETBACK 329'15'329'20' GRAVEL ACCESS ROAD 7' GAME FENCE PROJECT AREA 80 7 804 801 798 795 792 789 786 785 R5 0 ' MAX 20' WIDTH GRAVEL FARM ACCESS ROAD PER OWNER REQUEST (NO GRADING TO OCCUR, CONTRACTOR SHOULD PLACE GRAVEL ON EXISTING GRADE)809EXISTING VEGETATION/TREE LINE EXISTING VEGETATION/TREE LINE LANDSCAPE BUFFER "A1" WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.8 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.12 MATCHLINE - SEE SHEET C-4.91 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.4 MATCHLINE - SEE SHEET C-4.74.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDINV 4 784 784783782781780785783782781780810 809 805810801802803804806807808809DETENTION POND 1M (SEE SHEET D-5I) PROPOSED ARRAYS (TYP.)15'329'15'329'220'32'20'INVERTER SKID (TYP.) PROPOSED LIMIT OF DISTURBANCE 7' GAME FENCE GRAVEL ACCESS ROAD 814 812 810 808 806 804 802 800 798 796 794 792 7 9 0 78 9 78 8 786805803R 4 5 '786788790791784785 781801 79378778 7 8118128' R150' WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.9 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.13 MATCHLINE - SEE SHEET C-4.101 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.5 MATCHLINE - SEE SHEET C-4.84.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY 100' SET B A C K PROJECT AREA WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.10 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.14 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.6 MATCHLINE - SEE SHEET C-4.94.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLD LD LD LD LD LD LD LD LDLDLDLDLDLDLD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD815820 825 811812813814816817818 819 821 822 823 824 826 827 828 829 AREA TO REMAIN UNDISTURBED 7' GAME FENCE PROJECT AREA 329'15'329'160' PROPOSED LIMIT OF DISTURBANCE 329'15'329'329'PROPOSED LIMIT OF DISTURBANCE 8338378348 4 3 WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.11 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.16 MATCHLINE - SEE SHEET C-4.121 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.7 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LDLDLDLDLDLDLD LDLD LD LD LD LDLDLDLDLDLDINV 5 INV 1 INV 2 785786787788 789790790789 788787786785 785 790 789 788787786 798797796795794793797797792796800801802803804805 806 807 808 803804805806807808808797798799800801802803804805806807809808807782 782 7 8 3 792793794795796798798796795794793792815820814816817818819795800805791 7 9 2 7937 9 4 7967977987998018028038048 0 6 807805 810 815 820 825 803 804 806 807 808 809 811 812 813 814 816 817 818 819 821 822 823 824 826 827 82 0 81 9 82 1 8 2 2 8 2 3 820 821 822792793794795796797797796795794793792DETENTION POND 1B (SEE SHEET D-5B) DETENTION POND 1C (SEE SHEET D-5C) DETENTION POND 1G (SEE SHEET D-5F) DETENTION POND 1H (SEE SHEET D-5F) DETENTION POND 1I (SEE SHEET D-5G) INV. IN = 781.50'329'15'329'15'329'20' 72' 20' R 4 0 ' R40'329'24'329'20'INVERTER SKID (TYP.)20'15'INVERTER SKID (TYP.) GRAVEL ACCESS ROAD GRAVEL ACCESS ROAD CONCRETE DRIVEWAY APRON (SEE D-6) 80' PROPOSED LIMIT OF DISTURBANCE 7' GAME FENCE 53' 20' 33'15'329'PROPOSED LIMIT OF DISTURBANCE R100' R100' INV. OUT = 794.00' INV. IN = 796.00' 70' - 15" HDPE @ 2.86% 786 785 8028018007997988048028007997 9 7 7 9 9 ACCESS GATE (SEE D-6)20'12' GRAVEL FARM ACCESS ROAD PER OWNER REQUEST (NO GRADING TO OCCUR, CONTRACTOR SHOULD PLACE GRAVEL ON EXISTING GRADE) 7' GAME FENCE 7' GAME FENCE 807808808807810808 809812 813 814816815817 818 819 821 822 824 826828830833837834 8288 2 9 8297 9 8 798800805806807808809 807805803803805807809 807 805 8 1 1812811 811 810 808 806 80 6 808 810 811 813 815 816 81678 4 785 786 790 792 794 79 6 79 8 80 0 802 15'15' 8' 13'60'WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.12 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.17 MATCHLINE - SEE SHEET C-4.131 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.8 MATCHLINE - SEE SHEET C-4.114.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD L D LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LDLDLD LD LD LD LDLDLDLDINV 5 778 778 777 776 775774773772 777 776 775774773 772 772 773 800 799 798 797 796 795794 793792791 790789 788 787 786 785 784 783 782 781 780 779 778 777 775 776 77877877 1 778777776775772786 785 784 783 782 781 780 779 778 777 776 81 0 81 1 81 2 81 3 81 4 81 5 81 6 81 7 81 8 819 82 0 82 1 82 1 820 81 9 818 81 7 816 828 827 826 825 824 823 822 8 2 1 820 816 821821789790785 784 783 782 781 780 780 779 779 780 781 782 783 784 785 785 790 795 800 788 789 791 792 793 794 796 797 798 799 8 0 1 802803804780 785 790 795 800 779 781 782 783 784 786 787 788 789 791 792 793 794 796 797 798 799 801802 803 795 800 805 810 815796 797 798 799 801 802 803 804 806807808809811 812813 814 810809811812DETENTION POND 1J (SEE SHEET D-5G) DETENTION POND 1K (SEE SHEET D-5H) DETENTION POND 1L (SEE SHEET D-5H) DITCH DA IJ INV. OUT = 780.50' 100' - 18" HDPE @ 1.00% PROPOSED ARRAYS (TYP.) 7' CHAIN LINK FENCE PROPOSED LIMIT OF DISTURBANCE 100'SETBACKPROJECT AREA EXISTING WETLAND 329'15'20'329'15'19'72' 20' R 4 0 ' R40' INVERTER SKID (TYP.)220'786 785 CONCRETE DRIVEWAY APRON (SEE D-6)779783782784809 807 805 8 1 1 811 810 808 806 80 6 808 810 811 813 815 816 81678 4 785 786 790 792 794 79 6 79 8 80 0 802 EXISTING VEGETATION/TREE LINE 15'60'WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.13 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.18 MATCHLINE - SEE SHEET C-4.141 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.9 MATCHLINE - SEE SHEET C-4.124.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY PROJECT AREA 100'SETBACKEXISTING WETLAND WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.14 SITE & GRADING PLAN-1 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.10 MATCHLINE - SEE SHEET C-4.134.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY PROJECT AREA 200'SETBACKSP R I N G D A L E R O A D RO U T E 6 4 9 - 5 0 ' R / W WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.15 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.19 MATCHLINE - SEE SHEET C-4.161 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LDLDLD LD L DLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LDLDLDLDLDLANDSCAPE BUFFER "B1" LANDSCAPE BUFFER "B1"810811812813810 815808 809 811 812 813814816 815816814 815 816 817 818 81 9 820 821 820 825 819821 822 823 824 826 827 8 1 3 8 1 4 8 1 5 8168178178168158148 1 3 8 1 2 811 813814 815 80 8 80 9 81 0 81 1 813814815 815 814 813 812 81 1 81 0 809808809810811812813814815DETENTION POND 1-1A (SEE SHEET D-5K) DETENTION POND 1-1B (SEE SHEET D-5L) GRAVEL ACCESS ROAD LEASED AREA 15'7' CHAIN LINK FENCE GRAVEL ACCESS ROAD 22' 20'15'329'20'19'220'15'CONTRACTOR SHALL INSTALL 50' WIDE, 25' LONG, 18" DEEP VDOT CLASS 1 RIP RAP BELOW OUTFALL OF CONCRETE DRIVEWAY FLOW SECTION. 7' GAME FENCE 330'SP R I N G D A L E R O A D RO U T E 6 4 9 - 5 0 ' R / W100'SETBACKPROPOSED LIMIT OF DISTURBANCE PROPOSED LIMIT OF DISTURBANCE PROJECT AREA 33' 20'15'15'100'SETBACK200' SETBACK PROJECT AREA 808809R65' 20'R35'R35'R50'R40' ACCESS GATE (SEE D-6) ACCESS GATE (SEE D-6) R45'R45' R45'R45'8178 1 4 812 810 808 807 80981481281080881 3 8 1 1 810 80' - 15" RCP @ 1.25% INV OUT- 810 INV IN- 811 811.5 811.3810.5 810.3 MATCH EXISTING MATCH EXISTING 8 1 2 81 3 8 1 1 811 811812 81 2 81 3 CONCRETE DRIVEWAY FLOW SECTION (SEE D-6) 1% EXISTING VEGETATION/TREE LINE EXISTING VEGETATION/TREE LINE CONTRACTOR SHALL INSTALL 8' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 4' WIDE TO 10' WIDE. 20' ACCESS EASEMENT TO BE GRANTED TO FREDERICK WATER 90'WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.16 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.20 MATCHLINE - SEE SHEET C-4.171 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.11 MATCHLINE - SEE SHEET C-4.154.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY L D L D LD LD LD LDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDL D LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDINV 6 INV 8INV 7 LANDSCAPE BUFFER "B1" LANDSCAPE BUFFER "B1"8218218208198188178168158148138128118108098088108118128138148108018028038048058068078088098108118128138148148268258248238228208188168158 2 3 820 816817 818 819 821 822 8 2 0 8 1 7 8 1 8 81 9 8 2 1 8 2 2 810815820825811812813814816817818819821822823824826827828828 828829829 825821 82282382480 1 80 0 79 9 79 8 79 7796795794 793792806 807 808 809 810 811 812 812 811 810 809 808 807 806 80 7 8 0 8 8 0 9 8 1 0 8 1 1 8 1 3 8 1 4 8 1 5 8 1 5 8 1 4 8 1 3 8 1 2 8 1 1 8 1 0 8 0 9 8 0 8 DETENTION POND 1C (SEE SHEET D-5C) DETENTION POND 1E (SEE SHEET D-5D) DETENTION POND 1F (SEE SHEET D-5E)329'DITCH DA IG329'15'329'15'20'329'20' R15'R15' R4 8 ' INVERTER SKID (TYP.) INVERTER SKID (TYP.) INVERTER SKID (TYP.)220'GRAVEL ACCESS ROAD GRAVEL ACCESS ROAD S P R I NG D A L E RO A D RO U T E 6 4 9 - 5 0 ' R /W PROPOSED LIMIT OF DISTURBANCE 20' 7 9 9 8 0 1 8048068087' GAME FENCE 8128108088058 0 3 8 0 0 7 9 8 8168158158168178 1 5 814813813812816816 817 818 819820821822824826828 829 831 832 833 834 841 838 836 833 83 2 830828 834831836 83884174'68' 8' WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.17 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.21 MATCHLINE - SEE SHEET C-4.181 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.12 MATCHLINE - SEE SHEET C-4.164.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDL D 845 850 843 844 846 847 848 849 85 1 85 2 821822823824825826827828829830831832833834835835834833832831830824 825 826 827 828 829 830 831 831830829828 827 831832833834831832833834DETENTION POND 6A (SEE SHEET D-5O) DETENTION POND 7C (SEE SHEET D-5N) DETENTION POND 7A (SEE SHEET D-5O)329'15'329'15'19'220'329'19'220'15'329'20'220'19'220'100' SETB A C K PROPOSED LIMIT OF DISTURBANCE 7' GAME FENCE PROJECT AREA EXISTING WETLAND PROPOSED ARRAYS (TYP.) EXISTING VEGETATION/TREE LINE EXISTING VEGETATION/TREE LINE WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.18 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.22 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.13 MATCHLINE - SEE SHEET C-4.174.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY PROJECT AREA 200' SET B A C K 100' SET B A C K EXISTING VEGETATION/TREE LINE WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.19 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.23 MATCHLINE - SEE SHEET C-4.201 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.15 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDINV 9 825 830835 826 827828 829 8318328 3 3 834 83 6 832 8 3 3 8 3 4 825830 835 826827828 829 831 832 833 834 836 837838 839 826 827 15'330'15'330'15'330'7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE PROJECT AREA 2 0 0 ' S E T B A C K 7' GAME FENCE EXISTING VEGETATION/TREE LINE EXISTING VEGETATION/TREE LINE EXISTING VEGETATION/TREE LINE WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.20 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.24 MATCHLINE - SEE SHEET C-4.211 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.16 MATCHLINE - SEE SHEET C-4.194.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLD LD LD LDLDL D L D LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDINV 9 INV 14 LANDSCAPE BUFFER "B1" LANDSCAPE BUFFER "B1"825823824826830 835840831 8328338348368378388398418428438308 3 0 8358288 2 8 8298 2 9 83183 1 8328 3 2 83383483682 5 83 0 835 8 2 3 82 4 82 6 8 2 7 82 8 8 2 9 8318 3 2 8338 3 4 836 83 7 830835827 828829831832833834836820825830819 821822 823 824 826827828829808809810811812813814815DETENTION POND 1-1B (SEE SHEET D-5L) DETENTION POND 1-1C (SEE SHEET D-5M) INVERTER SKID (TYP.) 8 3 783683522' 79'SPRINGDA LE ROADROUTE 6 4 9 - 5 0 ' R /W 100' SET B A C K 15' 100' SET B A C K 15' 7' GAME FENCE 7' GAME FENCE220'20'LANDSCAPE BUFFER "B1" LANDSCAPE BUFFER "B1"330'20'220'15'20' PROPOSED LIMIT OF DISTURBANCE PROJECT AREA 8258228228228228208218218 2 0 819 818817 816817816 817 818 8 1 9 SPRINGDALE ROADROUTE 649 - 50' R/WEXISTING VEGETATION/TREE LINE 18' 19' 25' WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.21 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.25 MATCHLINE - SEE SHEET C-4.221 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.17 MATCHLINE - SEE SHEET C-4.204.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY L D LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD85 2 850 847 848 849 851 840 841 842 843 843 842 841840825826827828829830830829 828827826825DETENTION POND 7B (SEE SHEET D-5P) DETENTION POND 8A (SEE SHEET D-5P)220'329'100'SETBACK7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE PROJECT AREA PROPOSED ARRAYS (TYP.) EXISTING VEGETATION/TREE LINE EXISTING VEGETATION/TREE LINE WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.22 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.26 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.18 MATCHLINE - SEE SHEET C-4.214.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLD100'SETBACKPROPOSED LIMIT OF DISTURBANCE PROJECT AREA EXISTING VEGETATION/TREE LINE WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.23 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.27 MATCHLINE - SEE SHEET C-4.241 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.19 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDINV 10 INV 11835840845850855832833834836837 838 839 841842843844846847848849851852853854856857858845850841842843844846847848849851852853854850855847848849851 852 853 854 856 857 858 859 15'330'15'330'15'330'15'7' GAME FENCE 7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE PROPOSED ARRAYS (TYP.) LEASED AREA100'SET B A C K EXISTING VEGETATION/TREE LINE EXISTING VEGETATION/TREE LINE WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.24 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.28 MATCHLINE - SEE SHEET C-4.251 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.20 MATCHLINE - SEE SHEET C-4.234.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY 1061 826.56 MB 296 0.00%LDLDLDLDLDLDLD LD LD LD LD LD LD LD LD INV 10 INV 11 INV 15 LANDSCAPE BUFFER "B1"830829831835 840 845 850 833 834836837 838 839 841 842 843 844 846 847 848 849 851 852 857858840845850855860841842843844846 847 848849851852 853854856857858859 815 820 825 830 814 816 817 818 819 821 822 823 824 826 827 828 829 831 832 833 825 8 2 1 8 2 2 8 2 3 8 2 4 826827828829827826825824823822SUMP 15A (SEE SHEET D-5S) INVERTER SKID (TYP.) INVERTER SKID (TYP.) SPRIN G D A L E R O A D ROUTE 6 4 9 - 5 0 ' R / W 22' 100' SETBACK 15' 7' GAME FENCE PROJECT AREA GRAVEL ACCESS ROAD330'15'19'221'840 839 837 838 835 831828827825824 19' 17' 18' WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.25 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.29 MATCHLINE - SEE SHEET C-4.261 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.21 MATCHLINE - SEE SHEET C-4.244.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY 1087 826.88 MB 1216 LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLANDSCAPE BUFFER "B1" 81 5 820 8 2 5 8 1 2 8 1 3 8 1 4 816 817 818 819 821 822 823 824 8 2 6 827 828 829 8 2 2 8 2 3 802803804805806807808808807806805804803802DETENTION POND 16A (SEE SHEET D-5S) SPRIN G D A L E R O A D ROUTE 6 4 9 - 5 0 ' R / W R450'INVERTER SETBACK100'SETBACK7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE 15'PROJECT AREA 15'330'20' S PR I NGD A L E RO AD RO U T E 6 4 9 - 5 0 ' R /W WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.26 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.30 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.22 MATCHLINE - SEE SHEET C-4.254.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLDLDLDLDLDLDLDLD100' SET B A C K PROJECT AREA 7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE330'221'20'20'EXISTING VEGETATION/TREE LINE EXISTING VEGETATION/TREE LINE WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.27 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.281 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.23 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDINV 12 INV 13 INV 16 INV 1785085586086584985185285385485685785885986186286386486684585085584384484684784884985185285385485685785885985983 4 83 5 835 83 3 83 3 856 855 853 851850 849 848 848 849 850 851 851 850 849 848 DETENTION POND 13A (SEE SHEET D-5R) INVERTER SKID (TYP.) INVERTER SKID (TYP.) INVERTER SKID (TYP.) 854 15'330'15'330'7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE 22' PROPOSED ARRAYS (TYP.)100'SETBACKGRAVEL ACCESS ROADR60'844845845846 848 850 852 854 854852855856857858859857 858859 EXISTING VEGETATION/TREE LINE 18' 14' 18' WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.28 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.291 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.24 MATCHLINE - SEE SHEET C-4.274.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLD DC AC INV 19 INV 1884083783883984183 0 82882983 1 835 840 845 850 855 833 834 836 837 838 839 841 842 843 844 846 847 848 849 851 852 853 854 856 857 858 859 825 830 835 840 8 2 2 8 2 3 824 826 827 828 829 831 832 833 834 836 837 838 839 841 842 843 84 4845 85085584384484684784884985185285385485685785884 5 850 855 846 847 848 849 851 852 853 854 856 857835833834836837 840845850855860865838839841842843844846847848849851852853854856857858859861862863864INVERTER SKID (TYP.)15'R15' R 4 8 ' 20' 7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE GRAVEL ACCESS ROAD8 2 1 823 823 824 827 8 2 9 8 3 383683 7 838839841 842846849865 865 865 865 865 86586615' R15' R15'R15'9'WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.29 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.31 MATCHLINE - SEE SHEET C-4.301 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.25 MATCHLINE - SEE SHEET C-4.284.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLDL D LDLDLDLDLDLDLDLDLD LD LD LDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD 802 803804805806807808808807 806805804803802808809810811812813814815816816815814813812DETENTION POND 17A (SEE SHEET D-5T) DETENTION POND 16A (SEE SHEET D-5S) 7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE PROJECT AREA 100' SET B A C K PROPOSED ARRAYS (TYP.) Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.30 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.32 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.26 MATCHLINE - SEE SHEET C-4.294.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDINV 19 LANDSCAPE BUFFER "C1" 850 851 851 850 GRAVEL ACCESS ROAD 25'100'SETBACK22'20'R30'R40'22'7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE PROJECT AREA 818 819 820 821 822 823 824 825 826 827 828 825 828 8 2 38248258268278228 2 1 820829832834836837844846848850852854856858860862865866808 80 7 80 6 810 WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.31 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.34 MATCHLINE - SEE SHEET C-4.321 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.29 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LD LD LD LDLDLDLDLDLDLD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDINV 20 INV 21 INV 22 LANDSCAPE BUFFER "C" 8 0 0 8 0 5 7 9 9 80 1 8 0 2 8 0 3 8 0 4 80 6 80 7 80 8 8 0 9 781782783783782781780779778SUMP 18A (SEE SHEET D-5U) INVERTER SKID (TYP.) INVERTER SKID (TYP.) INVERTER SKID (TYP.) 7' GAME FENCE 100' SET B A C K 100' SET B A C K 7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE 22'GRAVEL ACCESS ROAD PROJECT AREA PROPOSED LIMIT OF DISTURBANCE PROPOSED ARRAYS (TYP.) R100' R15 0'7927 9 3794796800802803805808810 811 812813 80780980 6 80 4 80 3 802 TOWN OF STEPHENS CITY LIMITS (BOLD DASHED LINE) TOWN OF STEPHENS CITY LIMITS (BOLD DASHED LINE) TOWN OF STEPHENS CITY LIMITS (BOLD DASHED LINE) EXISTING VEGETATION/TREE LINE 27'17'20'WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.32 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.34 MATCHLINE - SEE SHEET C-4.331 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.30 MATCHLINE - SEE SHEET C-4.31MATCHLINE - SEE SHEET C-4.35 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LD LD LD LD LD LD LD LD LD L D L D L D L D L D LD LD LD LD LD LD LD LD LD LD LD LD 770 768 769 771 772 75 7 75 8 75 9 76 0 76 1 76 2 76 3 76 4 76 4 76 3 76 2 76 1 76 0 75 9 75 8 75 6 DETENTION POND 18B (SEE SHEET D-5U) PROPOSED ARRAYS (TYP.) PROJECT AREA PROPOSED LIMIT OF DISTURBANCE 7' GAME FENCE DI T C H D A 1 8 C100'SETBACKTOWN OF STEPHENS CITY LIMITS (BOLD DASHED LINE) TOWN OF STEPHENS CITY LIMITS (BOLD DASHED LINE) WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.33 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.35 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 50MATCHLINE - SEE SHEET C-4.32MATCHLINE - SEE SHEET C-4.36 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLANDSCAPE BUFFER "F1" 787 788 789 79 4 79 3 792 79 1 79 0 78 9 78 8 787 786 785 801 800 799 798 797 796 795 79460'100'SETBACK7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE 450'INVERTER SETBACKPROPOSED ARRAYS (TYP.) TREES TO BE PROTECTED PROPOSED LIMIT OF DISTURBANCE 40' - 15" HDPE @ 2.5% INV OUT- 787 INV IN- 788 TOWN OF STEPHENS CITY LIMITS (BOLD DASHED LINE) EXISTING VEGETATION PRESERVATION AREA EXISTING VEGETATION/TREE LINE WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.34 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.351 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.31 MATCHLINE - SEE SHEET C-4.32 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY T 1129 794.18 TP T 1131 790.09 TP LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDINV 25 INV 22 INV 23 LANDSCAPE BUFFER "D1" LANDSCAPE BUFFER "F1" 770 775 780785 769 771 772 773 774 776 777 778 779 781782 783 784 786 787 788 771 772 773 774 775 776 777 777 776 775 774 773 772 771 77 8 77 9 78 0 78 1 78 2 78 3 78 4 78 5 786 787 788 789 DETENTION POND 19A (SEE SHEET D-5V) INVERTER SKID (TYP.) INVERTER SKID (TYP.) GR A V E L A C C E S S R O A D 7' GAME FENCE 100'SETBACK60'450' INVERTER SETBACK PROPOSED ARRAYS (TYP.)22'75'PROPOSED LIMIT OF DISTURBANCE 7 7 7778779782785788790791784783 782 78120'20'WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.35 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.37 MATCHLINE - SEE SHEET C-4.361 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.32 MATCHLINE - SEE SHEET C-4.34MATCHLINE - SEE SHEET C-4.33 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LD LD LD LD LD LD LDLDLDLD LD LD LDLDLDLDLDLDLD LDLDLDLDLDLDLDLDLDLDLDLDLDLDINV 25 INV 24 75 6 75 7 75 8 75 9 76 0 76 1 76 2 76 3 76 4 76 4 76 3 76 2 76 1 76 0 75 9 75 8 75 7 DETENTION POND 18B (SEE SHEET D-5U) INVERTER SKID (TYP.) INVERTER SKID (TYP.)22'GRAVEL ACCESS ROAD 7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE 100'SETBACKPROJECT AREA PROPOSED ARRAYS (TYP.) R50'R50'ACCESS GATE (SEE D-6)R200'7617647637737747757 7 6 7 7 7 PASSAGE ROADP A S S A G E R O A D TOWN OF STEPHENS CITY LIMITS (BOLD DASHED LINE)18'17'WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.36 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.38 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.33 MATCHLINE - SEE SHEET C-4.354.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLANDSCAPE BUFFER "D1"100'SETBACK450' INVERTER SETBACK 60'7' CHAIN LINK FENCE PROPOSED LIMIT OF DISTURBANCE PROJECT AREA TOWN OF STEPHENS CITY LIMITS (BOLD DASHED LINE) EXISTING VEGETATION PRESERVATION AREA WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.37 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.381 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.35 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY T 1127 760.90 TP T 1128 761.91 TP LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDPROPOSED ARRAYS (TYP.) 7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE PROJECT AREA100'SETBACKPASSAGE ROADTOWN OF STEPHENS CITY LIMITS (BOLD DASHED LINE) WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.38 SITE & GRADING PLAN-1 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.36 MATCHLINE - SEE SHEET C-4.374.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY OHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP O H P O H P OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP LDLDLDLDLDLDLDLDLDLDLDLDLD LDLDLDLD LD LDLDLDLDLDLDLDLDLDLDLDLDMAR L B O R O R O A D ROU T E 6 3 1 - 3 0 ' P R E S C R I P T I V E R / W PROJECT AREA PROPOSED LIMIT OF DISTURBANCE STRODE MCLOED LANE TO BE IMPROVED TO 20' WIDTH FOLLOWING ROAD DETAIL R80'R60' 20'7887867847 8 3 7 8 1 7 7 9 7 7 7 7 7 5 7 7 3 77 1 STRODE MCLEOD LNRESERVED FOR ORCHARD RESERVED FOR ORCHARD WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.39 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.40 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY OHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPLAYDOWN LAYDOWNLAYDOWNLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDINV 26 78 0 78 1 78 2 78 3 78 4 78 4 78 3 78 2 78 1 7 8 0 762761760759758757756DETENTION POND 27C (SEE SHEET D-5Z) INVERTER SKID (TYP.) PROJECT AREA 7' GAME FENCE GRAVEL ACCESS ROAD PROPOSED LIMIT OF DISTURBANCE R60'R60'R200'R50' R50'R50'22'22'22' PROPOSED ARRAYS (TYP.)79579 7 793791789787780 778 776 775 78578277977777377176876876576377 5 77 6 777STRODE MCLEOD LNSTRODE MCLEOD LNRESERVED FOR ORCHARD RESERVED FOR ORCHARD 48' R50' 10 % M A X S L O P E 10 % M A X S L O P E ACCESS GATE (SEE D-6) WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.40 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.44 MATCHLINE - SEE SHEET C-4.411 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.39 MATCHLINE - SEE SHEET C-4.45 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LAYDOWN LD LDLDLDLDLD LD LDLDLDLDLDLDLDLDLDLDLDLD756757758759760761762762761760759758757756PROJECT AREA100'SETBACKPROPOSED LIMIT OF DISTURBANCE RESERVED FOR PASTURE WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.41 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.45 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 50MATCHLINE - SEE SHEET C-4.40MATCHLINE - SEE SHEET C-4.46 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY OHP OHP OH POHPOHPOHPOHPOHPOHPOHP LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDINV 41 LANDSCAPE BUFFER "B2"815820825830835840813814816817818819821822823824826827828829831832833834836837838839841842802 803 804 805 806 806 805 804 803 802 801 806805804803802802801800DETENTION POND 39A (SEE SHEET D-5JJ) PROJECT AREA 7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE 100'SETBACK25'DITCH DA 37A7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE EXISTING VEGETATION/TREE LINE RESERVED FOR CROPS R45'R4 5 '9'20'120'WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.42 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.47 MATCHLINE - SEE SHEET C-4.431 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.48 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLANDSCAPE BUFFER "A2"815816817818835840845850836837838839841842843844846847848849851100'SETBACK25'PROPOSED LIMIT OF DISTURBANCE 20'R150'GRAVEL ACCESS ROAD PROPOSED ARRAYS (TYP.) 7' GAME FENCE PROJECT AREA 7' GAME FENCE 60' 18" HDPE @ 3.33% 60' 18" HDPE @ 3.33% INV IN- 838 8 3 8 8 4 1 843847852 EXISTING VEGETATION/TREE LINE EXISTING VEGETATION/TREE LINE ACCESS GATE (SEE D-6) WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.43 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.48 MATCHLINE - SEE SHEET C-4.441 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.424.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY OHPLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDINV 34 790 795 800 789 791 792 793 794 796 797 798 799 801 802 775780776777778779781782783 780 785 790 776 777 778 779 781 782 783 784 786 787 788 789 791 792 775 780785 790 771 772 773 774 776 777 778 779781 782 783 784 786 787 788 78 9 787785790795786787788789791792793794796797790795786787788789791792793794796797805 8 1 0 81 5 801 802 803 804 8 0 6 8 0 7 808 809 8 1 181281 3 814 8 1 6 8 1 7 8 1 8 PROJECT AREA PROPOSED LIMIT OF DISTURBANCE 7' GAME FENCE PROPOSED ARRAYS (TYP.) INVERTER SKID (TYP.) 22'GRAVEL ACCESS ROAD 799 798 796 794 794 777 782 783 785788 792 791 79 0 788 787 785 786 783 776 778 RESERVED FOR ORCHARD EXISTING VEGETATION/TREE LINE 10' WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.44 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.49 MATCHLINE - SEE SHEET C-4.451 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.40 MATCHLINE - SEE SHEET C-4.434.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD INV 27 INV 28772771770768767766765764763762761760759758757756755755756757758759760761762762761760759758757756756775 771 772 773 774 776 77 0 7757807857 6 7 76876977177 2 773774776777778779781782783784786787DETENTION POND 27D (SEE SHEET D-5Z) SEDIMENT BASIN 27C (SEE SHEET D-4Z) PROPOSED LIMIT OF DISTURBANCE PROJECT AREA 7' GAME FENCE 100'SETBACK22'R200'R100' PROPOSED ARRAYS (TYP.) INVERTER SKID (TYP.) INVERTER SKID (TYP.) EXISTING WETLAND ACCESS GATE (SEE D-6) ACCESS GATE (SEE D-6) 763 766 768 770 772774772770767763760757754752750747744RESERVED FOR PASTURE 57'60'79'R15' R15' R15' R15'70'10 % M A X S L O P E 10 % M A X S L O P E 10% M A X S L O P E10% MAX SLOPE20' 20' WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.45 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.50 MATCHLINE - SEE SHEET C-4.461 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.40 MATCHLINE - SEE SHEET C-4.44MATCHLINE - SEE SHEET C-4.41 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY OHPOHPOHPOHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHPOHPOHPOHPOHPOHP OHP OHP OHP OHP OHP OHP OHP OHP LDLDLDLDLDLDLDLD LDLDLDLDLDLDLDLD L D L D LDLDLD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD7 2 6 7 2 7 7277287297307317317307297287277327337347357367377427417407397387377367 2 8 72 9 730731 725726727728729731 732 733 734 735 73072972 4 72 5 72 6 72 7 72 8 72 9 73 0 73 0 72 9 72 8 72 7 72 6 72 5 72 4 730DETENTION POND 23A (SEE SHEET D-5W) DETENTION POND 27A (SEE SHEET D-5X) DETENTION POND 27B (SEE SHEET D-5Y) POI STATION AC COLLECTOR STATION PROPOSED LIMIT OF DISTURBANCE LEASED AREA GRAVEL ACCESS ROAD 2 2 '40'CONCRETE DRIVEWAY APRON (SEE D-6) 7' GAME FENCE PROPOSED ARRAYS (TYP.)R50'R60'737 734732731736730730731 2PARKING SPACES TO BE PROVIDED VIA CONCRETE PARKING STOPS CSX RAILROADCSX RAILROADTOWN OF STEPHENS CITY LIMITS (BOLD DASHED LINE) TOWN OF STEPHENS CITY LIMITS (BOLD DASHED LINE) RESERVED FOR PASTURE EXISTING VEGETATION/TREE LINE LANDSCAPING BUFFER "E1"R80' 10 % M A X S L O P E 10% MAX SLOPE10% MAX SLOPE4'4'WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.46 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.51 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.41 MATCHLINE - SEE SHEET C-4.454.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LANDSCAPE BUFFER "B2"8007997987977917927937947957 9 6 796 795 794 793 792 791 DETENTION POND 37A (SEE SHEET D-5JJ) PROPOSED ARRAYS (TYP.)PROPOSED LIMIT OF DISTURBANCE 25' PROJECT AREA 7' GAME FENCE 7' GAME FENCE EXISTING VEGETATION/TREE LINER4 5 ' WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.47 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.481 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.42 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLD LD LD L D L D LD L D LD L D L D LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDINV 39 INV 41 830 835829831 832 833 834 836 800805801802803804PROPOSED LIMIT OF DISTURBANCE INVERTER SKID (TYP.) GRAVEL ACCESS ROAD 20'PROPOSED ARRAYS (TYP.)R150'R4 5 ' R45' 20' PROJECT AREA 7' GAME FENCE 7' GAME FENCE 7' GAME FENCE 8 3 6 8 3 9 8 4 2 8 4 4 8 4 6 8 4 8 85 0 851 848 846 843 839 836 833 831 828 824 830 827 824 821 818 816 814 812 810 808 805 81581381180980680380060' 18" HDPE @ 3.33% 60' 18" HDPE @ 3.33% INV IN- 838 8 3 8 8 4 1 843847852 INV IN- 836 EXISTING VEGETATION/TREE LINE9'35'55'81'ACCESS GATE (SEE D-6) WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.48 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.52 MATCHLINE - SEE SHEET C-4.491 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.43 MATCHLINE - SEE SHEET C-4.47MATCHLINE - SEE SHEET C-4.53 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDL D L D LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD795800796797798799801802800805 797798799801802803804 806807808809 800 805 810 799 801 802 803 804 806 807 808 809 790 795 80 0 7 9 1 79 2 793 794 7 9 6 7 9 7 798 79 9 80 1 800 796 797 798 799 801802800805810815801 802803804806807808809811812813814816817818 79078778878979179220'20'20'R100'R100'R45'R 4 5 ' 7' GAME FENCE PROJECT AREA PROPOSED LIMIT OF DISTURBANCE R90' R110' R90' PROPOSED ARRAYS (TYP.) GRAVEL ACCESS ROAD EXISTING WETLAND803800797800804807808806810803800797795794794795811809808806803800804 803 800 797 794 792 788 786 794794 794 796797RESERVED FOR ORCHARD WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.49 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.53 MATCHLINE - SEE SHEET C-4.501 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.44 MATCHLINE - SEE SHEET C-4.48MATCHLINE - SEE SHEET C-4.54 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY INV 35 INV 29 INV 36795800796797798799801 775780771772773774776777778 779 781 782 783784790 795 80 0 789 791 792 793 794 796 797 798 79 9 801 7 9 0 795 791 792 793 794 796 755760756757758759R 4 5 ' R45'20'22' 22' INVERTER SKID (TYP.) GRAVEL ACCESS ROAD PROPOSED ARRAYS (TYP.) 787 788 789 788 787 791 793794795 798797796 790788789791792 793 795 797 799 800 12' 15' 12' 17' WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.50 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.54 MATCHLINE - SEE SHEET C-4.511 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.45 MATCHLINE - SEE SHEET C-4.49MATCHLINE - SEE SHEET C-4.55 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY RR OHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDPROPOSED ARRAYS (TYP.) 10 0 ' S E T B A C K 7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE PROJECT AREA CSX RAILROADCSX RAILROADTOWN OF STEPHENS CITY LIMITS (BOLD DASHED LINE) EXISTING VEGETATION/TREE LINE WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.51 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.55 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.46 MATCHLINE - SEE SHEET C-4.504.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LDLDLANDSCAPE BUFFER "B" AREA TO REMAIN UNDISTURBED PROJECT AREA PROPOSED LIMIT OF DISTURBANCE PROPOSED ARRAYS (TYP.) 7' GAME FENCE 7' GAME FENCE EXISTING VEGETATION/TREE LINE 76' WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.52 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.56 MATCHLINE - SEE SHEET C-4.531 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.48MATCHLINE - SEE SHEET C-4.47 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDINV 38 INV40 795800805 794796797798799801802803804790795800805 791792793 794 796 797798799801802803804806 770 775 7 6 6 767 768 769 771 772 773 774 776 775 77 4 776 7677667657647 6 3 76 0 DETENTION POND 28F (SEE SHEET D-5DD) AREA TO REMAIN UNDISTURBED R70' R15'R15' R5 0 ' INVERTER SKID (TYP.) INVERTER SKID (TYP.) R20'R 2 0 ' R4 8 ' 20' GRAVEL ACCESS ROAD PROPOSED LIMIT OF DISTURBANCE 7' GAME FENCE PROJECT AREA PROPOSED ARRAYS (TYP.) 20' PROPOSED LIMIT OF DISTURBANCE 7' GAME FENCE PROJECT AREA RESERVED FOR ORCHARD 66' 28' WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.53 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.57 MATCHLINE - SEE SHEET C-4.541 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.49 MATCHLINE - SEE SHEET C-4.524.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLD LDLDLDLDLDLDLDLDLDLD LD LDL D LD LDLDLDINV 30 INV 31 INV 36 801 802803780785776 777778779781782783784786787788 770 770775775 771771772772773773774774 7767757 8 0 776777778779787 7887 8 7 788760761762763764765766767767766765764763762761763 764 765 766767 768 769 770 771 771 770 769 768 767 766 765 764 763 7637 6 4 763762761760759758DETENTION POND 28C (SEE SHEET D-5BB) DETENTION POND 28E (SEE SHEET D-5CC) DETENTION POND 28F (SEE SHEET D-5DD)76476522' EXISTING WETLAND INVERTER SKID (TYP.) PROPOSED ARRAYS (TYP.) GRAVEL ACCESS ROAD PROPOSED LIMIT OF DISTURBANCE INVERTER SKID (TYP.) 7' GAME FENCE 7988007947 9 3 79 2 79 5 789788787 786 782 781 780779778 777 776 775 77477677777812' 15' 15'17'16' 34' WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.54 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.58 MATCHLINE - SEE SHEET C-4.551 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.49 MATCHLINE - SEE SHEET C-4.53MATCHLINE - SEE SHEET C-4.50 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY OHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPLDLD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD770775767768769771772773774770771772773774775776776775774773772771DETENTION POND 29A (SEE SHEET D-5FF) 100 ' SE T B A C K PROPOSED LIMIT OF DISTURBANCE GAME FENCE EXISTING WELANDS TOWN OF STEPHENS CITY LIMITS (BOLD DASHED LINE) PROPOSED ARRAYS (TYP.)CSX RAILROADEXISTING VEGETATION/TREE LINE WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.55 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.58 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.51 MATCHLINE - SEE SHEET C-4.54MATCHLINE - SEE SHEET C-4.50 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLDLDL D L D LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLANDSCAPE BUFFER "B2" LANDSCAPE BUFFER "B" 768 769 770 771 772 773 774 775 775 774 773 772 771 770 DETENTION POND 34A (SEE SHEET D-5II)25'PROPOSED LIMIT OF DISTURBANCE PROJECT AREA200'SETBACKPROPOSED ARRAYS (TYP.) PROPOSED LIMIT OF DISTURBANCE 7' GAME FENCE 7' GAME FENCE PROJECT AREA RESERVED FOR ORCHARD WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.56 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.571 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.52 MATCHLINE - SEE SHEET C-4.53 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD L D LDLDLDLDLDLDLDLANDSCAPE BUFFER "B2" 759 760 775 771 77 2 773 77 4 776 760765 770759761762 763 764 766 767 768 769 771 772 770 775780769 771 772 77377477677777877976 3 76 4 76 5 76 6 76 7 76 7 76 6 76 5 76 4 76 3 773 771 769 767 765 763 761 759 752753754755756757758758757756755754753758759760761762763764764763762761760759758755756757758759760760759758757756755754753754755756757758759760760759758757756755760DETENTION POND 28B (SEE SHEET D-5AA) DETENTION POND 28A (SEE SHEET D-5AA) DETENTION POND 28C (SEE SHEET D-5BB) DETENTION POND 28G (SEE SHEET D-5EE) DETENTION POND 33A (SEE SHEET D-5II)25'200'SETBACKPROPOSED LIMIT OF DISTURBANCE 7' GAME FENCE PROJECT AREA PROPOSED ARRAYS (TYP.) PROPOSED LIMIT OF DISTURBANCE 7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE 7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE 7' GAME FENCE EXISTING VEGETATION/TREE LINE RESERVED FOR ORCHARD 18' 20' WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.57 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.59 MATCHLINE - SEE SHEET C-4.581 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.53 MATCHLINE - SEE SHEET C-4.56MATCHLINE - SEE SHEET C-4.54 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY OHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDINV 37 INV 32 787 788789 760765 770759761762 763 764 766 767 768 769 771 772 758760761762763764765766766765764763762761DETENTION POND 30A (SEE SHEET D-5FF) 22' INVERTER SKID (TYP.) INVERTER SKID (TYP.) GRAVEL ACCESS ROAD 7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE PROPOSED ARRAYS (TYP.) 100' SETB A C K PROJECT AREA777778779780781 782 783 78 3 7827817 8 0 779 778 777 784785773 774776775786787CSX RAILROADCSX RAILROADEXISTING VEGETATION/TREE LINE15' 12' 13' WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.58 SITE & GRADING-MATCHLINE - SEE SHEET C-4.60 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.54 MATCHLINE - SEE SHEET C-4.57MATCHLINE - SEE SHEET C-4.55 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY LDLDLDLDLD LD LDLDL D LD LD LD LANDSCAPE BUFFER "C2" LANDSCAPE BUFFER "B2" LANDSCAPE BUFFER "B2"757758759760760759758757756 755 770771772773DETENTION POND 28A (SEE SHEET D-5AA)25'40'PROPOSED LIMIT OF DISTURBANCE 7' GAME FENCE PROJECT AREA PROPOSED ARRAYS (TYP.)200'SETBACKEXISTING VEGETATION/TREE LINE EXISTING VEGETATION/TREE LINE 761764767770772774WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.59 SITE & GRADING PLAN-MATCHLINE - SEE SHEET C-4.601 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.57 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY OHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPLD LD LDLDLD LDLDLDLDLDL D L D L D L D LD L D LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDINV 33 LANDSCAPE BUFFER "B2" LANDSCAPE BUFFER "C2" 774 773 772 757756755754753752751750749746746 747748749750751752755754753752751756757DETENTION POND 30B (SEE SHEET D-5GG)40'200'SETBACK100' SET B A C K 7' CHAIN LINK FENCE22'200' R 4 5 'R45'22' GRAVEL ACCESS ROAD PROPOSED ARRAYS (TYP.) LEASED AREA PROPOSED LIMIT OF DISTURBANCE 7' GAME FENCE PROPOSED LIMIT OF DISTURBANCE PROPOSED LIMIT OF DISTURBANCE PROJECT AREA787785784783 782 781780 779 778763761 760 762765766767 CSX RAILROADCSX RAILROADEXISTING VEGETATION/TREE LINE EXISTING VEGETATION/TREE LINE 13' 16' 17' WATER VALVE UTILITIES LEGEND: EXIST / PROPOSED FIRE HYDRANT WATER METER FIRE DEPT. CONNECTION (FDC) AIR RELEASE VALVE (ARV) POST INDICATOR VALVE (PIV) PLUG & BLOCK REDUCER MECHANICAL JOINT / BEND EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN SANITARY SEWER MANHOLE SEWER CLEAN OUT DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC SS W G JUNCTION BOX UGE Know what's below. before you dig.Call R BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_S C-4.60 SITE & GRADING PLAN-1 inch = ft. GRAPHIC SCALE ( IN FEET ) 50 MATCHLINE - SEE SHEET C-4.58 MATCHLINE - SEE SHEET C-4.594.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 4.224.214.204.19 4.23 4.24 4.25 4.26 4.304.294.284.27 4.31 4.32 4.33 4.364.354.34 4.37 4.38 4.39 4.40 4.41 4.464.454.444.434.42 4.47 4.48 4.49 4.50 4.51 4.554.544.534.52 4.56 4.57 4.58 4.604.59 SHEET KEY 9.4' 22.1' 3.6'5.4' 4 . 4 ' 21.7'2.1'4 . 9 '5.6'4.9' 10.0'27.4'9.3'1.2'5.0' 5.2' 4.2' 4 . 7 ' 5.3'14.6'32.1'29.5'9.0'9.0'9.4'10.7'8.6'10.7'8.6' T T T TTT RR OHPOHPOHPOHPOHPOHP OHPT T T 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 1000 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_DD C-5.0 PRE-DEVELOPMENT DRAINAGEAREASGRADING & STORM LEGEND: EXIST / PROPOSED LIMITS OF DISTURBANCE & TREE PROTECTION FENCE EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) LIMITS OF DISTURBANCE EXISTING STORM PIPE PROPOSED STORM PIPE LD JUNCTION BOX TREE PROTECTION FENCE PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 TP TP LD/TP LD/TP D S T EXISTING GAS METER EXISTING GAS REGULATOR EXISTING WATER VALVE EXISTING WATER METER EXISTING CLEANOUT EXISTING FIRE HYDRANT EXISTING UTILITY POLE EXISTING LIGHT POLE EXISTING BOLLARD EXISTING POST INDICATOR VALVE EXISTING SANITARY SEWER MANHOLE EXISTING TELEPHONE PEDESTAL EXISTING ELECTRIC ACCESS DELINEATION LINE Tc FLOW PATH C-5.1 C-5.2 C-5.3 9.4' 22.1' 3.6'5.4' 4 . 4 ' 21.7'2.1'4 . 9 '5.6'4.9' 10.0'27.4'9.3'1.2'5.0' 5.2' 4.2' 4 . 7 ' 5.3'14.6'32.1'29.5'9.0'9.0'9.4'10.7'8.6'10.7'8.6'OH E 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 400 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_DD C-5.1 PRE-DEVELOPMENT DRAINAGEAREASMATCHLINE - SEE SHEET C-5.2 DA 18 DA 19 DA 19 OFFSITE DA 18 OFFSITE DA 16 Tc FLOW PATH DA 16 OFFSITE DA 1E OFFSITE DA 8 DA 7 DA 6 DA 15 DA 1-1 DA 11 DA 12 DA 13 DA 11 OFFSITE DA 9 DA 10 DA 1 OFFSITE 4 DA 1 OFFSITE 5 DA 1 OFFSITE 3 DA 1 OFFSITE 2 DA 1-2 DA 1 DA 2 DA 1 OFFSITE 1 DA 2-1 DA 2-2 Tc FLOW PATH Tc FLOW PATH Tc FLOW PATH Tc FLOW PATH Tc FLOW PATH Tc FLOW PATH GRADING & STORM LEGEND: EXIST / PROPOSED LIMITS OF DISTURBANCE & TREE PROTECTION FENCE EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) LIMITS OF DISTURBANCE EXISTING STORM PIPE PROPOSED STORM PIPE LD JUNCTION BOX TREE PROTECTION FENCE PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 TP TP LD/TP LD/TP D S T EXISTING GAS METER EXISTING GAS REGULATOR EXISTING WATER VALVE EXISTING WATER METER EXISTING CLEANOUT EXISTING FIRE HYDRANT EXISTING UTILITY POLE EXISTING LIGHT POLE EXISTING BOLLARD EXISTING POST INDICATOR VALVE EXISTING SANITARY SEWER MANHOLE EXISTING TELEPHONE PEDESTAL EXISTING ELECTRIC ACCESS DELINEATION LINE Tc FLOW PATH 9.4' 22.1' 3.6'5.4' 4 . 4 ' 21.7'2.1'4 . 9 '5.6'4.9' 10.0'27.4'9.3'1.2'5.0' 5.2' 4.2' 4 . 7 ' 5.3'14.6'32.1'29.5'9.0'9.0'9.4'10.7'8.6'10.7'8.6' T T RR T T T 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 400 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_DD C-5.2 PRE-DEVELOPMENT DRAINAGEAREASDA 28 Tc FLOW PATH DA 18 OFFSITE DA 13 Tc FLOW PATH Tc FLOW PATH GRADING & STORM LEGEND: EXIST / PROPOSED LIMITS OF DISTURBANCE & TREE PROTECTION FENCE EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) LIMITS OF DISTURBANCE EXISTING STORM PIPE PROPOSED STORM PIPE LD JUNCTION BOX TREE PROTECTION FENCE PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 TP TP LD/TP LD/TP D S T EXISTING GAS METER EXISTING GAS REGULATOR EXISTING WATER VALVE EXISTING WATER METER EXISTING CLEANOUT EXISTING FIRE HYDRANT EXISTING UTILITY POLE EXISTING LIGHT POLE EXISTING BOLLARD EXISTING POST INDICATOR VALVE EXISTING SANITARY SEWER MANHOLE EXISTING TELEPHONE PEDESTAL EXISTING ELECTRIC ACCESS DELINEATION LINE Tc FLOW PATH MATCHLINE - SEE SHEET C-5.1 MATCHLINE - SEE SHEET C-5.3 DA 18 DA 19 DA 19 OFFSITE DA 20 DA 16 DA 12 DA 11 DA 11 OFFSITE DA 1-1 DA 27 DA 24 DA 25 DA 27 OFFSITE 1 DA 27 OFFSITE 2 DA 28 OFFSITE 1 DA 23 DA 39 OFFSITE DA 39 DA 37 DA 36 DA 28 OFFSITE 2 DA 40 OFFSITE T RR 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 400 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_DD C-5.3 PRE-DEVELOPMENT DRAINAGEAREASDA 28 Tc FLOW PATH GRADING & STORM LEGEND: EXIST / PROPOSED LIMITS OF DISTURBANCE & TREE PROTECTION FENCE EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) LIMITS OF DISTURBANCE EXISTING STORM PIPE PROPOSED STORM PIPE LD JUNCTION BOX TREE PROTECTION FENCE PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 TP TP LD/TP LD/TP D S T EXISTING GAS METER EXISTING GAS REGULATOR EXISTING WATER VALVE EXISTING WATER METER EXISTING CLEANOUT EXISTING FIRE HYDRANT EXISTING UTILITY POLE EXISTING LIGHT POLE EXISTING BOLLARD EXISTING POST INDICATOR VALVE EXISTING SANITARY SEWER MANHOLE EXISTING TELEPHONE PEDESTAL EXISTING ELECTRIC ACCESS DELINEATION LINE Tc FLOW PATH MATCHLINE - SEE SHEET C-5.2 DA 27 DA 24 DA 25 DA 27 OFFSITE 1 DA 27 OFFSITE 2 DA 28 OFFSITE 1 DA 23 DA 39 OFFSITE DA 39 DA 37 DA 36 DA 28 OFFSITE 2 DA 30 DA 29 DA 31 DA 32 DA 33 DA 34 DA 35 DA 34 OFFSITE 9.4' 22.1' 3.6'5.4'4. 4 ' 21.7'2.1'4. 9 '5.6'4.9' 10.0'27.4'9.3'1.2'5.0' 5.2' 4.2' 4 . 7 ' 5.3'14.6'32.1'29.5'9.0'9.0'9.4'10.7'8.6'10.7'8.6' T T T TTT RR OHPOHPOHPOHPOHPOHP OHPT T T0.00%1 inch = ft. GRAPHIC SCALE ( IN FEET ) 1000 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_DD C-6.0 POST-DEVELOPMENT DRAINAGEAREASGRADING & STORM LEGEND: EXIST / PROPOSED LIMITS OF DISTURBANCE & TREE PROTECTION FENCE EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) LIMITS OF DISTURBANCE EXISTING STORM PIPE PROPOSED STORM PIPE LD JUNCTION BOX TREE PROTECTION FENCE PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 TP TP LD/TP LD/TP D S T EXISTING GAS METER EXISTING GAS REGULATOR EXISTING WATER VALVE EXISTING WATER METER EXISTING CLEANOUT EXISTING FIRE HYDRANT EXISTING UTILITY POLE EXISTING LIGHT POLE EXISTING BOLLARD EXISTING POST INDICATOR VALVE EXISTING SANITARY SEWER MANHOLE EXISTING TELEPHONE PEDESTAL EXISTING ELECTRIC ACCESS DELINEATION LINE Tc FLOW PATH DA 18B C-6.1 C-6.2 C-6.3 9.4' 22.1' 3.6'5.4' 4 . 4 ' 21.7'2.1'4 . 9 '5.6'4.9' 10.0'27.4'9.3'1.2'5.0' 5.2' 4.2' 4 . 7 ' 5.3'14.6'32.1'29.5'9.0'9.0'9.4'10.7'8.6'10.7'8.6'OH E 0.00%1 inch = ft. GRAPHIC SCALE ( IN FEET ) 400 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_DD C-6.1 POST-DEVELOPMENT DRAINAGEAREASMATCHLINE - SEE SHEET C-6.2 DA 18A DA 19 DA 19 OFFSITE DA 16A Tc FLOW PATH DA 16 OFFSITE DA 1E OFFSITE DA 8A DA 7B DA 6B DA 15 DA 1-1B DA 11C DA 12B DA 13A DA 11 OFFSITE DA 9 DA 10 DA 1 OFFSITE 4 DA 1 OFFSITE 5 DA 1 OFFSITE 3 DA 1 OFFSITE 2 DA 1-2 DA 1O DA 2B DA 1 OFFSITE 1 DA 2-1B DA 2-2 Tc FLOW PATH Tc FLOW PATH Tc FLOW PATH Tc FLOW PATH Tc FLOW PATH Tc FLOW PATH GRADING & STORM LEGEND: EXIST / PROPOSED LIMITS OF DISTURBANCE & TREE PROTECTION FENCE EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) LIMITS OF DISTURBANCE EXISTING STORM PIPE PROPOSED STORM PIPE LD JUNCTION BOX TREE PROTECTION FENCE PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 TP TP LD/TP LD/TP D S T EXISTING GAS METER EXISTING GAS REGULATOR EXISTING WATER VALVE EXISTING WATER METER EXISTING CLEANOUT EXISTING FIRE HYDRANT EXISTING UTILITY POLE EXISTING LIGHT POLE EXISTING BOLLARD EXISTING POST INDICATOR VALVE EXISTING SANITARY SEWER MANHOLE EXISTING TELEPHONE PEDESTAL EXISTING ELECTRIC ACCESS DELINEATION LINE Tc FLOW PATH DA 7A DA 7C DA 6A DA 1K DA 8B DA 1-1A DA 1-1C DA 1-3A DA 1-3B DA 1-1J DA 1I DA 1H DA 1G DA 1F DA 1E DA 1M DA 1L DA 2A DA 2-1A DA 1A DA 1B DA 1C DA 1D DA 1 OFFSITE 6 DA 11A DA 11B DA 12A DA 13B DA 16B DA 16C DA 18A OFFSITE DA 18B DA 18C OFFSITE DA 18B OFFSITE DA 1 OFFSITE 1 TO DA 1N DA 1N 9.4' 22.1' 3.6'5.4' 4 . 4 ' 21.7'2.1'4.9 '5.6'4.9' 10.0'27.4'9.3'1.2'5.0' 5.2' 4.2' 4 . 7 ' 5.3'14.6'32.1'29.5'9.0'9.0'9.4'10.7'8.6'10.7'8.6' T T RR T T T0.00%1 inch = ft. GRAPHIC SCALE ( IN FEET ) 400 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_DD C-6.2 POST-DEVELOPMENT DRAINAGEAREASMATCHLINE - SEE SHEET C-6.1 DA 18A DA 19A DA 16A DA 11C DA 12B DA 13A DA 11 OFFSITE Tc FLOW PATH Tc FLOW PATH GRADING & STORM LEGEND: EXIST / PROPOSED LIMITS OF DISTURBANCE & TREE PROTECTION FENCE EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) LIMITS OF DISTURBANCE EXISTING STORM PIPE PROPOSED STORM PIPE LD JUNCTION BOX TREE PROTECTION FENCE PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 TP TP LD/TP LD/TP D S T EXISTING GAS METER EXISTING GAS REGULATOR EXISTING WATER VALVE EXISTING WATER METER EXISTING CLEANOUT EXISTING FIRE HYDRANT EXISTING UTILITY POLE EXISTING LIGHT POLE EXISTING BOLLARD EXISTING POST INDICATOR VALVE EXISTING SANITARY SEWER MANHOLE EXISTING TELEPHONE PEDESTAL EXISTING ELECTRIC ACCESS DELINEATION LINE Tc FLOW PATH DA 11A DA 11B DA 12A DA 13B DA 16B DA 18A OFFSITE DA 18B DA 18C OFFSITE DA 18B OFFSITE DA 18C DA 19A OFFSITE TO POND DA 19B DA 19B OFFSITE TO POND DA 20DA 40 OFFSITE DA 39 OFFSITE MATCHLINE - SEE SHEET C-6.3 DA 27 OFFSITE 1 DA 27 OFFSITE 2 DA 28 OFFSITE1 DA 28E DA 27D DA 27C DA 24 DA 25A DA 25C DA 27B DA 27E DA 27A DA 23A DA 23B DA 28F DA 39A DA 37A DA 36 DA 28 OFFSITE 2 DA 34 OFFSITE DA 37B DA 39B T RR 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 400 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_DD C-6.3 POST-DEVELOPMENT DRAINAGEAREASGRADING & STORM LEGEND: EXIST / PROPOSED LIMITS OF DISTURBANCE & TREE PROTECTION FENCE EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) LIMITS OF DISTURBANCE EXISTING STORM PIPE PROPOSED STORM PIPE LD JUNCTION BOX TREE PROTECTION FENCE PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 TP TP LD/TP LD/TP D S T EXISTING GAS METER EXISTING GAS REGULATOR EXISTING WATER VALVE EXISTING WATER METER EXISTING CLEANOUT EXISTING FIRE HYDRANT EXISTING UTILITY POLE EXISTING LIGHT POLE EXISTING BOLLARD EXISTING POST INDICATOR VALVE EXISTING SANITARY SEWER MANHOLE EXISTING TELEPHONE PEDESTAL EXISTING ELECTRIC ACCESS DELINEATION LINE Tc FLOW PATH DA 39 OFFSITE MATCHLINE - SEE SHEET C-6.2 DA 27 OFFSITE 1 DA 27 OFFSITE 2 DA 28 OFFSITE1 DA 28E DA 27D DA 27C DA 24 DA 25A DA 25C DA 27B DA 27E DA 27A DA 23A DA 23B DA 28F DA 39A DA 37A DA 36 DA 28 OFFSITE 2 DA 34 OFFSITE DA 37B DA 39B DA 28C DA 28B DA 28A DA 29A DA 29B DA 30A DA 30B DA 30C DA 31A DA 31B DA 32A DA 32B DA 28HDA 33A DA 33B DA 34A DA 34B DA 35 DA 28G 9.4' 22.1' 3.6'5.4'4. 4 ' 21.7'2.1'4.9 '5.6'4.9' 10.0'27.4'9.3'1.2'5.0' 5.2' 4.2' 4 . 7 ' 5.3'14.6'32.1'29.5'9.0'9.0'9.4'10.7'8.6'10.7'8.6' T T T TTT RR OHPOHPOHPOHPOHPOHP OHPT T T 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 1000 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_DD C-7.0 PRE-DEVELOPMENT LANDCOVERC-7.1 C-7.2 C-7.3 9.4' 22.1' 3.6'5.4' 4 . 4 ' 21.7'2.1'4 . 9 '5.6'4.9' 10.0'27.4'9.3'1.2'5.0' 5.2' 4.2' 4 . 7 ' 5.3'14.6'32.1'29.5'9.0'9.0'9.4'10.7'8.6'10.7'8.6'OH E 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 400 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_DD C-7.1 PRE-DEVELOPMENT LANDCOVERMATCHLINE - SEE SHEET C-7.2 DA 18 DA 19 DA 19 OFFSITE DA 18 OFFSITE DA 16 DA 16 OFFSITE DA 1E OFFSITE DA 8 DA 7 DA 6 DA 15 DA 1-1 DA 11 DA 12 DA 13 DA 11 OFFSITE DA 9 DA 10 DA 1 OFFSITE 4 DA 1 OFFSITE 5 DA 1 OFFSITE 3 DA 1 OFFSITE 2 DA 1-2 DA 1 DA 2 DA 1 OFFSITE 1 DA 2-1 DA 2-2 Tc FLOW PATH LANDCOVER KEY IMPERVIOUS GRAVEL (B SOIL) GRAVEL (C SOIL) GRAVEL (D SOIL) WOODS (B SOIL) WOODS (C SOIL) WOODS (D SOIL) MEADOW (B SOIL) MEADOW (C SOIL) MEADOW (D SOIL) ROW CROPS (B SOIL) ROW CROPS (C SOIL) ROW CROPS (D SOIL) ORCHARD (B SOIL) ORCHARD (C SOIL) ORCHARD (D SOIL) 9.4' 22.1' 3.6'5.4' 4 . 4 ' 21.7'2.1'4 . 9 '5.6'4.9' 10.0'27.4'9.3'1.2'5.0' 5.2' 4.2' 4 . 7 ' 5.3'14.6'32.1'29.5'9.0'9.0'9.4'10.7'8.6'10.7'8.6' T T RR T T T 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 400 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_DD C-7.2 PRE-DEVELOPMENT LANDCOVERDA 28 DA 18 OFFSITE DA 13 Tc FLOW PATH MATCHLINE - SEE SHEET C-7.1 MATCHLINE - SEE SHEET C-7.3 DA 18 DA 19 DA 19 OFFSITE DA 20 DA 16 DA 12 DA 11 DA 11 OFFSITE DA 1-1 DA 27 DA 24 DA 25 DA 27 OFFSITE 1 DA 27 OFFSITE 2 DA 28 OFFSITE 1 DA 23 DA 39 OFFSITE DA 39 DA 37 DA 36 DA 28 OFFSITE 2 DA 40 OFFSITE LANDCOVER KEY IMPERVIOUS GRAVEL (B SOIL) GRAVEL (C SOIL) GRAVEL (D SOIL) WOODS (B SOIL) WOODS (C SOIL) WOODS (D SOIL) MEADOW (B SOIL) MEADOW (C SOIL) MEADOW (D SOIL) ROW CROPS (B SOIL) ROW CROPS (C SOIL) ROW CROPS (D SOIL) ORCHARD (B SOIL) ORCHARD (C SOIL) ORCHARD (D SOIL) T RR 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 400 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_DD C-7.3 PRE-DEVELOPMENT LANDCOVERDA 28 MATCHLINE - SEE SHEET C-7.2 DA 27 DA 24 DA 25 DA 27 OFFSITE 1 DA 27 OFFSITE 2 DA 28 OFFSITE 1 DA 23 DA 39 OFFSITE DA 39 DA 37 DA 36 DA 28 OFFSITE 2 DA 30 DA 29 DA 31 DA 32 DA 33 DA 34 DA 35 DA 34 OFFSITE LANDCOVER KEY IMPERVIOUS GRAVEL (B SOIL) GRAVEL (C SOIL) GRAVEL (D SOIL) WOODS (B SOIL) WOODS (C SOIL) WOODS (D SOIL) MEADOW (B SOIL) MEADOW (C SOIL) MEADOW (D SOIL) ROW CROPS (B SOIL) ROW CROPS (C SOIL) ROW CROPS (D SOIL) ORCHARD (B SOIL) ORCHARD (C SOIL) ORCHARD (D SOIL) BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_DD C-7.4 PRE-DEVELOPMENT LANDCOVER 9.4' 22.1'3.6'5.4'4. 4 ' 21.7'2.1'4. 9 '5.6'4.9' 10.0'27.4'9.3'1.2'5.0' 5.2' 4.2' 4 . 7 ' 5.3'14.6'32.1'29.5'9.0'9.0'9.4'10.7'8.6'10.7'8.6' T T T TTT RR OHPOHPOHPOHPOHPOHP OHPT T T 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 1000 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_DD C-8.0 POST-DEVELOPMENT LAND COVERC-8.1 C-8.2 C-8.3 9.4' 22.1' 3.6'5.4' 4 . 4 ' 21.7'2.1'4 . 9 '5.6'4.9' 10.0'27.4'9.3'1.2'5.0' 5.2' 4.2' 4 . 7 ' 5.3'14.6'32.1'29.5'9.0'9.0'9.4'10.7'8.6'10.7'8.6'OH E 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 400 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_DD C-8.1 POST-DEVELOPMENT LAND COVERMATCHLINE - SEE SHEET C-8.2 DA 18A DA 19 DA 19 OFFSITE DA 16A Tc FLOW PATH DA 16 OFFSITE DA 1E OFFSITE DA 8A DA 7B DA 6B DA 15 DA 1-1B DA 11C DA 12B DA 13A DA 11 OFFSITE DA 9 DA 10 DA 1 OFFSITE 4 DA 1 OFFSITE 5 DA 1 OFFSITE 3 DA 1 OFFSITE 2 DA 1-2 DA 1O DA 2B DA 1 OFFSITE 1 DA 2-1B DA 2-2 Tc FLOW PATH Tc FLOW PATH DA 7A DA 7C DA 6A DA 1K DA 8B DA 1-1A DA 1-1C DA 1-3A DA 1-3B DA 1-1J DA 1I DA 1H DA 1G DA 1F DA 1E DA 1M DA 1L DA 2A DA 2-1A DA 1A DA 1B DA 1C DA 1D DA 1 OFFSITE 6 DA 11A DA 11B DA 12A DA 13B DA 16B DA 16C DA 18A OFFSITE DA 18B DA 18C OFFSITE DA 18B OFFSITE DA 1 OFFSITE 1 TO DA 1N DA 1N LANDCOVER KEY IMPERVIOUS GRAVEL (B SOIL) GRAVEL (C SOIL) GRAVEL (D SOIL) WOODS (B SOIL) WOODS (C SOIL) WOODS (D SOIL) MEADOW (B SOIL) MEADOW (C SOIL) MEADOW (D SOIL) ROW CROPS (B SOIL) ROW CROPS (C SOIL) ROW CROPS (D SOIL) ORCHARD (B SOIL) ORCHARD (C SOIL) ORCHARD (D SOIL) 9.4' 22.1' 3.6'5.4' 4 . 4 ' 21.7'2.1'4.9 '5.6'4.9' 10.0'27.4'9.3'1.2'5.0' 5.2' 4.2' 4 . 7 ' 5.3'14.6'32.1'29.5'9.0'9.0'9.4'10.7'8.6'10.7'8.6' T T RR T T T 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 400 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_DD C-8.2 POST-DEVELOPMENT DRAINAGEAREASMATCHLINE - SEE SHEET C-8.1 DA 18A DA 19A DA 16A DA 11C DA 12B DA 13A DA 11 OFFSITE Tc FLOW PATH Tc FLOW PATH DA 11A DA 11B DA 12A DA 13B DA 16B DA 18A OFFSITE DA 18B DA 18C OFFSITE DA 18B OFFSITE DA 18C DA 19A OFFSITE TO POND DA 19B DA 19B OFFSITE TO POND DA 20DA 40 OFFSITE DA 39 OFFSITE MATCHLINE - SEE SHEET C-8.3 DA 27 OFFSITE 1 DA 27 OFFSITE 2 DA 28 OFFSITE1 DA 28E DA 27D DA 27C DA 24 DA 25A DA 25C DA 27B DA 27E DA 27A DA 23A DA 23B DA 28F DA 39A DA 37A DA 36 DA 28 OFFSITE 2 DA 34 OFFSITE DA 37B DA 39B LANDCOVER KEY IMPERVIOUS GRAVEL (B SOIL) GRAVEL (C SOIL) GRAVEL (D SOIL) WOODS (B SOIL) WOODS (C SOIL) WOODS (D SOIL) MEADOW (B SOIL) MEADOW (C SOIL) MEADOW (D SOIL) ROW CROPS (B SOIL) ROW CROPS (C SOIL) ROW CROPS (D SOIL) ORCHARD (B SOIL) ORCHARD (C SOIL) ORCHARD (D SOIL) T RR 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 400 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_DD C-8.3 POST-DEVELOPMENT LAND COVERDA 39 OFFSITE MATCHLINE - SEE SHEET C-8.2 DA 27 OFFSITE 1 DA 27 OFFSITE 2 DA 28 OFFSITE1 DA 28E DA 27D DA 27C DA 24 DA 25A DA 25C DA 27B DA 27E DA 27A DA 23A DA 23B DA 28F DA 39A DA 37A DA 36 DA 28 OFFSITE 2 DA 34 OFFSITE DA 37B DA 39B DA 28C DA 28B DA 28A DA 29A DA 29B DA 30A DA 30B DA 30C DA 31A DA 31B DA 32A DA 32B DA 28HDA 33A DA 33B DA 34A DA 34B DA 35 DA 28G LANDCOVER KEY IMPERVIOUS GRAVEL (B SOIL) GRAVEL (C SOIL) GRAVEL (D SOIL) WOODS (B SOIL) WOODS (C SOIL) WOODS (D SOIL) MEADOW (B SOIL) MEADOW (C SOIL) MEADOW (D SOIL) ROW CROPS (B SOIL) ROW CROPS (C SOIL) ROW CROPS (D SOIL) ORCHARD (B SOIL) ORCHARD (C SOIL) ORCHARD (D SOIL) BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_DD C-8.4 POST-DEVELOPMENT LAND COVER 9.4' 22.1' 3.6'5.4'4. 4 ' 21.7'2.1'4 .9 '5.6'4.9' 10.0'27.4'9.3'1.2'5.0' 5.2' 4.2' 4. 7 ' 5.3'14.6'32.1'29.5'9.0'9.0'9.4'10.7'8.6'10.7'8.6' T T T TTT RR OHPOHPOHPOHPOHPOHP OHP T T T INV 9 INV 10 INV 11 INV 14 INV 15 INV 12 INV 13 INV 16 INV 17 INV 20 INV 3 INV 4 INV 5 INV 6 INV 34 INV 35 INV 29 INV 30 INV 31 INV 36 INV 37 INV 32 INV 33 INV 38 INV 39 INV40 INV 41 DC AC INV 21 INV 25 INV 24 INV 22 INV 8INV 7 INV 27 INV 28 INV 26 INV 23 INV 1 INV 2 INV 19 INV 18 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 1000 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_DD C-9.0 WATER QUALITY DESIGNATIONSC-9.1 C-9.3 WATER QUALITY KEY C-9.2 9.4' 22.1' 3.6'5.4' 4 . 4 ' 21.7'2.1'4.9 '5.6'4.9' 10.0'27.4'9.3'1.2'5.0' 5.2' 4.2' 4 . 7 ' 5.3'14.6'32.1'29.5'9.0'9.0'9.4'10.7'8.6'10.7'8.6' T TT T OH E INV 9 INV 10 INV 11 INV 14 INV 15 INV 12 INV 13 INV 16 INV 17 INV 3 INV 4 INV 5 INV 6 DC AC INV 8INV 7 INV 1 INV 2 INV 18 L597 L596L595 L594 L593 L592 L591 L590 L589 L588 L587L586L585L584 L583 L582 L581L580 L579L578 L577 L576 L575 L574 L573 L572L571 L570 L569 L568 C 6 C 7 L 5 6 7 L 5 6 6 L5 6 5 C8L564 L563L562 L561L560L559L558L557 L556 L55 5 L554L553L552 L551 L550L549 L548L547 L546L545L54 4 L543L542L541 L540 L539 L538 L537L536L535L534L533L532 L531 L530L529L528 L527L526L525 L524 L523L522 L521 L 5 2 0 L519L518L517L516 L515L514L513L512L511 L510L509L508L507L506 L505 L504 L503 L502L501 L500L499L4 9 8 L497L496 L495 L494L493L492L491L490 L489L48 8 L487 L486 L485 L484 L483 L482 L481 L480 L479 L478 L477L476 L 4 7 5 L474 L473L472 L 4 7 1 L470 L469 L468 L467 L466 L465 L464 L 4 6 3L462L461 L460 L459 L458L457L456 L455L454L453 L452 L451 L450 L449L448 L447 L446L445 L444 L443 L442L441 L440 L439 L438 L437 L436L435 L434 L433 L432L431 L430 L429 L428 L427L426 L425L424 L423L422 L359 L358L357C9 L35 6 L355L354L353L352L351 L350 L349L348 L347 L346 L345L344L343L342L341L340 L339L338L33 7 L 3 3 6 L335L334 L33 1L330L32 9 L328 L32 7L326L325 L324L32 3 L322 L321L320L319 L318 L317 L316 L315 L31 4 L313L31 2 L311 L3101 inch = ft. GRAPHIC SCALE ( IN FEET ) 400 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_DD C-9.1 WATER QUALITY DESIGNATIONSFOREST/OPENSPACE KEY F/OS (B SOIL) F/OS (C SOIL) F/OS (D SOIL) WATER QUALITY NOTES IN ACCORDANCE WITH THE VIRGINIA RUNOFF REDUCTION METHOD, WATER QUALITY COMPLIANCE IS BEING MET WITH ON-SITE FOREST/OPEN SPACE, AS WELL AS THROUGH THE PURCHASE OF REMAIN TP LOAD REDUCTION. THE REMAINING REDUCTION WILL BE MET THROUGH THE PURCHASE OF NUTRIENT CREDITS. THIS FOREST/OPEN SPACE SHALL BE INCORPORATED INTO A DEEDED OPERATION AND MAINTENANCE AGREEMENT FOR THE LIFE OF THE PROJECT. THIS AREA SHALL BE LEFT IN A NATURAL VEGETATIVE STATE FOR THE LIFE OF THE PROJECT, BUT CAN BE BUSH HOGGED NO MORE THAN FOUR TIMES PER YEAR. THIS AREA SHOULD NOT BE DISTURBED DURING CONSTRUCTION. METES AND BOUNDS FOR THE FOREST/OPEN SPACE AREA ARE SHOWN ON SHEET C-9.3. WHEN THE LIFE CYCLE OF THE FACILITY IS OVER AND DECOMMISSIONING IS COMMENCED, THE LANDCOVER SHALL BE RETURNED TO THE PRE-DEVELOPMENT CONDITION. 9.4' 10.0'27.4'9.3'1.2'5.0' 5.2' 4.2'4.7 ' 5.3'14.6'32.1'9.0'T T RR OHPOHPOHPOHPOHPOHPOHPOHPOHPOHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHPOHP OHP OHPOHP T T T INV 12 INV 13 INV 16 INV 17 INV 20 INV 34 INV 35 INV 29 INV 30 INV 36 INV 39 INV40 INV 41 DC AC INV 21 INV 25 INV 24 INV 22 INV 27 INV 28 INV 26 INV 23 INV 19 INV 18 L655 L654 L65 3 L652L651 L650 L649L64 8 C5L64 7 L64 6 L64 5 L644L643L642 L641 L640 L639 L638 L637L6 3 6 L635 L634 L633 L632 L631 L630L629 L628L627 L626 L625 L624 L623 L622 L621 L620 L619 L618 L617 L616 L61 5 L614 L613 L612 L611 L610 L6 0 9 L6 0 8L607L606 L605L604L603L602L601 L600L599 L598L335L334 L3 3 3 L332 L33 1L330L32 9 L328 L32 7L326 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 400 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_DD C-9.1 WATER QUALITY DESIGNATIONSFOREST/OPENSPACE KEY F/OS (B SOIL) F/OS (C SOIL) F/OS (D SOIL) WATER QUALITY NOTES IN ACCORDANCE WITH THE VIRGINIA RUNOFF REDUCTION METHOD, WATER QUALITY COMPLIANCE IS BEING MET WITH ON-SITE FOREST/OPEN SPACE, AS WELL AS THROUGH THE PURCHASE OF REMAIN TP LOAD REDUCTION. THE REMAINING REDUCTION WILL BE MET THROUGH THE PURCHASE OF NUTRIENT CREDITS. THIS FOREST/OPEN SPACE SHALL BE INCORPORATED INTO A DEEDED OPERATION AND MAINTENANCE AGREEMENT FOR THE LIFE OF THE PROJECT. THIS AREA SHALL BE LEFT IN A NATURAL VEGETATIVE STATE FOR THE LIFE OF THE PROJECT, BUT CAN BE BUSH HOGGED NO MORE THAN FOUR TIMES PER YEAR. THIS AREA SHOULD NOT BE DISTURBED DURING CONSTRUCTION. METES AND BOUNDS FOR THE FOREST/OPEN SPACE AREA ARE SHOWN ON SHEET C-9.3. WHEN THE LIFE CYCLE OF THE FACILITY IS OVER AND DECOMMISSIONING IS COMMENCED, THE LANDCOVER SHALL BE RETURNED TO THE PRE-DEVELOPMENT CONDITION. T RR OHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHP OHP OHP OHP OHP OHP OHPOHPOHP OHPOHP INV 34 INV 35 INV 29 INV 30 INV 31 INV 36 INV 37 INV 32 INV 33 INV 38 INV 39 INV40 INV 41 INV 27 INV 28 INV 26 L637L6 3 6 L635 L634 L633 L632 L631 L630L629 L628L627 L626 L625 L624 L623 L622 L621 L620 L619 L618 L617 L616 L61 5 L614 L613 L612 L611 L610 L60 9 L6 0 8L607L606 L605L604L603L602L601 L600L599 L598L4 2 1 L420 L419 L418 L417 L416 L415 L414 L413L412L411 L410 L409 L408 L407 L406 L405 L404 L403L402 L401L400L399 L398 L397L396 L395L394L393L392 L391 L390 L389 L388 L387L386L385 L384 L383L382L381 L380 L379L378L377L376 L375 L374 L373L372L371 L370 L369 L3 6 8L367L366L365L364L363L362 L3 6 1 L360 1 inch = ft. GRAPHIC SCALE ( IN FEET ) 400 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_DD C-9.3 WATER QUALITY DESIGNATIONSFOREST/OPENSPACE KEY F/OS (B SOIL) F/OS (C SOIL) F/OS (D SOIL) WATER QUALITY NOTES IN ACCORDANCE WITH THE VIRGINIA RUNOFF REDUCTION METHOD, WATER QUALITY COMPLIANCE IS BEING MET WITH ON-SITE FOREST/OPEN SPACE, AS WELL AS THROUGH THE PURCHASE OF REMAIN TP LOAD REDUCTION. THE REMAINING REDUCTION WILL BE MET THROUGH THE PURCHASE OF NUTRIENT CREDITS. THIS FOREST/OPEN SPACE SHALL BE INCORPORATED INTO A DEEDED OPERATION AND MAINTENANCE AGREEMENT FOR THE LIFE OF THE PROJECT. THIS AREA SHALL BE LEFT IN A NATURAL VEGETATIVE STATE FOR THE LIFE OF THE PROJECT, BUT CAN BE BUSH HOGGED NO MORE THAN FOUR TIMES PER YEAR. THIS AREA SHOULD NOT BE DISTURBED DURING CONSTRUCTION. METES AND BOUNDS FOR THE FOREST/OPEN SPACE AREA ARE SHOWN ON SHEET C-9.3. WHEN THE LIFE CYCLE OF THE FACILITY IS OVER AND DECOMMISSIONING IS COMMENCED, THE LANDCOVER SHALL BE RETURNED TO THE PRE-DEVELOPMENT CONDITION. Parcel Table Line #/Curve # L638 L639 L640 L641 L642 L643 L644 L645 L646 L647 C5 L648 L649 L650 L651 L652 L653 L654 L655 L598 L599 L600 L601 L602 L603 L604 Length 63.623 161.444 80.098 0.525 125.778 18.590 242.672 107.945 1254.160 110.541 231.593 865.965 496.440 291.709 297.428 487.824 200.092 213.912 16.126 245.670 130.406 658.101 126.951 24.157 571.062 33.003 Direction/Delta S37° 37' 57.29"W N63° 44' 11.27"W N71° 16' 16.51"W N70° 11' 01.22"W N70° 11' 01.22"W N73° 49' 11.69"W S28° 24' 02.65"W N67° 41' 34.74"W N67° 41' 34.74"W N67° 41' 34.74"W 0.6209 S69° 50' 53.63"E N16° 56' 57.20"E S71° 06' 58.06"E S71° 06' 58.06"E S18° 10' 31.23"W S70° 06' 22.41"E S70° 06' 22.41"E S47° 21' 07.83"W S24° 04' 40.20"W S24° 04' 40.20"W N73° 28' 20.34"W N73° 28' 20.34"W N19° 52' 23.37"W N18° 41' 11.20"E N24° 57' 04.98"W Radius 21372.110 Parcel Table Line #/Curve # L605 L606 L607 L608 L609 L610 L611 L612 L613 L614 L615 L616 L617 L618 L619 L620 L621 L622 L623 L624 L625 L626 L627 L628 L629 L630 Length 160.453 214.928 485.677 224.373 480.868 81.545 14.131 83.613 5.486 148.857 303.134 151.280 95.430 100.470 126.203 120.999 51.214 30.386 36.372 49.215 72.562 29.958 79.904 161.867 164.449 317.135 Direction/Delta N19° 20' 57.04"E N19° 20' 57.04"E N19° 20' 57.04"E N64° 16' 38.68"W N64° 16' 38.68"W N64° 16' 38.68"W N62° 37' 31.90"E S71° 53' 24.37"E S71° 53' 24.37"E S65° 12' 58.38"E S66° 20' 33.55"E S66° 20' 33.55"E S84° 15' 25.94"E S26° 30' 03.43"E S22° 27' 00.63"E S12° 07' 17.67"E S10° 39' 35.01"W S15° 41' 24.98"E S36° 55' 49.51"E S7° 57' 18.27"E S54° 11' 09.07"W S45° 27' 22.22"W S30° 17' 49.51"W S5° 24' 54.95"W S82° 44' 47.73"W S8° 06' 15.28"W Radius Parcel Table Line #/Curve # L631 L632 L633 L634 L635 L636 L637 L570 L571 L572 L573 L574 L575 L576 L577 L578 L579 L580 L581 L582 L583 L584 L585 L586 L587 L588 Length 73.136 167.603 75.684 218.874 13.468 162.946 57.023 109.256 82.036 95.899 35.696 47.701 74.656 50.563 102.101 132.753 49.730 40.306 24.562 157.758 24.135 72.573 218.803 57.904 53.709 27.791 Direction/Delta S32° 03' 18.33"E N86° 23' 34.46"E N86° 23' 34.46"E S75° 14' 56.88"E S75° 14' 56.88"E S59° 10' 31.65"E S24° 04' 40.20"W N53° 50' 19.41"W N75° 29' 41.77"W S87° 37' 57.45"W S16° 20' 02.21"E S0° 51' 55.19"E S19° 32' 52.86"W S9° 27' 17.18"W N83° 59' 28.42"W N86° 19' 52.96"W N74° 14' 53.79"W N72° 45' 14.89"W S57° 01' 13.21"W S87° 59' 07.73"W N88° 59' 26.72"W S34° 41' 16.71"W N6° 31' 49.59"W N6° 31' 49.59"W S48° 11' 59.61"E N56° 59' 39.61"E Radius Parcel Table Line #/Curve # L589 L590 L591 L592 L593 L594 L595 L596 L597 L434 L435 L436 L437 L438 L439 L440 L441 L442 L443 L444 L445 L446 L447 L448 L449 L450 Length 35.071 83.865 107.672 215.873 56.520 347.166 65.313 247.478 72.156 2.863 118.900 81.913 146.214 63.727 34.599 144.005 110.827 44.963 166.317 117.938 91.697 376.986 74.789 47.099 21.641 4.691 Direction/Delta S86° 55' 50.53"E N76° 32' 37.76"E N89° 16' 39.85"E N59° 34' 02.71"E S86° 02' 30.80"E S86° 05' 19.06"E N83° 50' 02.61"E S0° 01' 19.75"E N56° 13' 29.21"W S64° 38' 08.67"W S64° 38' 08.67"W S47° 54' 31.34"E S14° 53' 28.56"W S15° 04' 21.97"E S16° 10' 02.65"E S25° 03' 46.42"W N63° 15' 09.38"W S81° 15' 41.37"W S17° 44' 37.75"W S19° 43' 14.41"W S3° 31' 47.65"W S22° 31' 48.66"W S77° 24' 36.24"W N89° 44' 44.98"W N67° 25' 00.31"W N18° 56' 05.19"E Radius Parcel Table Line #/Curve # L451 L452 L453 L454 L455 L456 L457 L458 L459 L460 L461 L462 L463 L464 L465 L466 L467 L468 L469 L470 L471 L472 L473 L474 L475 L476 Length 72.196 20.739 171.143 161.964 61.826 68.332 155.559 59.018 65.045 71.436 40.860 272.626 42.448 62.962 85.072 60.094 130.293 93.819 54.266 99.706 71.479 187.409 89.304 59.437 561.405 506.400 Direction/Delta N67° 09' 49.22"W N49° 44' 58.99"E N42° 27' 17.05"E N27° 54' 09.72"E N0° 07' 55.40"E N64° 23' 32.92"W N4° 05' 19.85"W N0° 52' 33.09"E N78° 57' 06.47"E S75° 46' 21.94"E N60° 58' 05.96"E N9° 56' 24.59"E N36° 31' 05.16"W N72° 34' 07.64"W N26° 59' 02.55"W N1° 30' 38.91"W N64° 30' 37.47"E N68° 55' 17.56"E N85° 12' 12.64"E N58° 49' 47.42"E N47° 42' 45.04"W N41° 04' 38.03"W N31° 15' 54.16"W N52° 08' 25.05"W N37° 38' 04.92"W S89° 54' 15.89"W Radius Parcel Table Line #/Curve # L477 L478 L479 L480 L481 L482 L483 L484 L485 L486 L487 L488 L489 L490 L491 L492 L493 L494 L495 L496 L497 L498 L499 L500 L501 L502 Length 45.849 74.053 358.086 77.310 91.934 70.475 67.251 61.130 146.157 45.072 58.865 68.649 115.268 128.180 70.476 120.721 261.132 277.771 50.368 21.674 74.128 209.632 126.130 173.489 295.607 245.015 Direction/Delta S64° 35' 08.95"W S62° 24' 20.34"W S63° 15' 30.62"W S72° 50' 58.43"W S64° 35' 08.95"W S56° 57' 28.08"W S8° 51' 25.02"W S1° 32' 51.45"W S3° 05' 54.43"W S12° 24' 30.56"W S78° 30' 52.30"W S53° 49' 39.10"W S29° 28' 33.92"W S18° 53' 37.67"W S8° 19' 49.53"W S23° 55' 38.88"E S1° 02' 29.74"W S19° 00' 23.73"E S10° 44' 59.22"W S47° 23' 34.83"W S10° 40' 18.24"E S60° 18' 04.84"E S19° 08' 16.98"E S0° 00' 00.00"E S72° 26' 14.28"W S30° 04' 07.91"W Radius Parcel Table Line #/Curve # L503 L504 L505 L506 L507 L508 L509 L510 L511 L512 L513 L514 L515 L516 L517 L518 L519 L520 L521 L522 L523 L524 L525 L526 L527 L528 Length 8.925 1.174 1.045 280.632 182.614 175.393 363.123 591.951 575.732 189.514 210.221 341.521 354.162 804.348 60.929 163.113 211.585 50.172 205.898 934.826 285.485 213.053 95.319 353.606 498.603 722.119 Direction/Delta S6° 23' 35.78"E S29° 59' 57.26"W S48° 11' 59.61"E S6° 23' 35.78"E S12° 45' 05.71"E S11° 28' 58.18"E S0° 09' 35.20"W S12° 15' 01.86"W S89° 59' 59.30"W N87° 32' 16.62"W S73° 28' 08.13"W S30° 49' 34.17"E S0° 32' 10.88"E S89° 50' 15.65"W S0° 35' 26.80"W S38° 50' 43.35"W S0° 57' 51.76"E S42° 33' 06.00"E N78° 21' 39.23"E N89° 57' 13.17"E N15° 52' 12.06"E N89° 57' 33.66"E S76° 04' 10.48"E N36° 38' 36.09"E N4° 45' 26.23"E N89° 36' 39.71"E Radius Parcel Table Line #/Curve # L529 L530 L531 L532 L533 L534 L535 L536 L537 L538 L539 L540 L541 L542 L543 L544 L545 L546 L547 L548 L549 L550 L551 L552 L553 L554 Length 375.921 301.156 171.197 238.650 169.288 151.340 156.096 91.058 74.368 149.979 47.287 277.184 118.523 320.122 2.159 239.293 1041.537 429.419 346.744 893.259 676.783 686.527 111.286 433.035 224.111 261.820 Direction/Delta N5° 56' 24.63"E N0° 41' 36.56"E N89° 22' 39.96"E N10° 01' 45.21"E N14° 18' 28.07"E N8° 11' 02.68"E N0° 09' 45.46"W N31° 20' 07.88"W N87° 28' 21.56"W N9° 44' 54.41"E N19° 07' 22.48"E N89° 44' 12.51"E N45° 16' 33.99"E N23° 11' 55.65"E N18° 56' 05.19"E S69° 22' 10.43"E S22° 55' 58.95"W S5° 21' 30.84"W N83° 16' 45.17"W S9° 05' 21.34"W N83° 09' 55.22"W S9° 10' 54.87"W N79° 35' 16.02"W S75° 26' 44.72"W S3° 52' 57.70"W S3° 52' 57.70"W Radius Parcel Table Line #/Curve # L555 L556 L557 L558 L559 L560 L561 L562 L563 L564 C8 L565 L566 L567 C7 C6 L568 L569 L422 L423 L424 L425 L426 L427 L428 L429 Length 399.966 667.020 522.627 688.290 97.000 568.689 2451.018 2009.552 1182.060 1922.158 77.183 492.450 306.499 151.182 133.430 187.868 64.736 62.432 49.954 558.396 287.294 506.345 208.428 344.344 162.004 319.900 Direction/Delta S54° 34' 21.86"W N82° 49' 14.40"W S52° 09' 14.84"W N28° 20' 24.16"W N28° 20' 09.40"W N25° 57' 31.64"W N21° 04' 09.90"E N64° 57' 37.08"E N28° 15' 13.05"W N64° 35' 08.95"E 21.5301 S37° 10' 33.05"E S38° 18' 59.05"E S38° 18' 59.05"E 11.1417 15.6874 S65° 08' 43.65"E N88° 09' 52.79"W N90° 00' 00.00"W S0° 05' 18.81"W N88° 33' 37.53"W N1° 28' 18.73"W N90° 00' 00.00"E N0° 00' 00.00"E N90° 00' 00.00"E N90° 00' 00.00"E Radius 205.400 686.159 686.160 Parcel Table Line #/Curve # L430 L431 L432 L433 L360 L361 L362 L363 L364 L365 L366 L367 L368 L369 L370 L371 L372 L373 L374 L375 L376 L377 L378 L379 L380 L381 Length 7.769 22.690 294.975 440.538 167.795 801.483 25.978 688.662 24.554 42.362 488.084 102.048 192.841 157.762 42.399 148.584 164.945 75.535 83.462 41.226 49.881 330.693 71.591 203.128 81.756 48.218 Direction/Delta N90° 00' 00.00"E S0° 26' 29.93"W S18° 30' 22.50"E N89° 36' 04.43"W S56° 57' 02.75"E S61° 03' 09.95"E S22° 09' 40.83"W S22° 09' 40.83"W N15° 17' 15.30"E N22° 03' 57.61"E N15° 17' 15.30"E N19° 40' 11.61"W N61° 01' 46.53"W S58° 16' 30.62"W S75° 58' 02.69"W N86° 06' 26.80"W N88° 13' 40.60"W N76° 15' 33.33"W S77° 54' 38.62"W S56° 00' 50.38"W S3° 25' 48.58"E S14° 09' 46.62"W S29° 00' 40.39"E S2° 54' 57.37"W S2° 31' 00.14"W S9° 04' 37.47"E Radius Parcel Table Line #/Curve # L382 L383 L384 L385 L386 L387 L388 L389 L390 L391 L392 L393 L394 L395 L396 L397 L398 L399 L400 L401 L402 L403 L404 L405 L406 L407 Length 88.655 220.379 21.809 19.081 36.792 23.183 50.525 42.843 20.326 68.853 101.750 142.179 123.745 44.473 24.993 25.180 43.882 73.674 86.553 122.884 56.278 68.063 26.021 13.979 51.375 40.499 Direction/Delta S2° 57' 19.52"W S5° 34' 03.35"W N77° 50' 39.84"W N77° 50' 39.84"W N42° 13' 25.59"W N8° 20' 26.08"W N10° 59' 45.52"W N49° 03' 52.57"W N79° 24' 50.39"W S77° 25' 15.49"W N6° 35' 55.85"W N3° 47' 36.61"E N4° 33' 20.28"E N13° 24' 36.54"E N30° 45' 26.31"W N10° 54' 56.83"W N10° 54' 56.83"W N0° 42' 36.61"E N23° 35' 19.20"E N5° 59' 42.18"E N86° 33' 44.61"E N1° 14' 17.27"W N67° 19' 59.02"W N67° 19' 59.02"W N51° 48' 22.78"W N11° 17' 03.40"E Radius Parcel Table Line #/Curve # L408 L409 L410 L411 L412 L413 L414 L415 L416 L417 L418 L419 L420 L421 L339 L340 L341 L342 L343 L344 L345 L346 L347 L348 L349 L350 Length 85.457 63.627 52.813 69.076 32.333 15.696 111.689 108.741 110.415 55.680 81.975 74.325 66.403 516.488 732.243 788.544 300.639 418.457 248.513 92.144 69.112 173.462 52.696 256.963 360.677 1274.171 Direction/Delta N4° 06' 01.28"W N1° 00' 17.91"W N47° 20' 18.42"E N40° 09' 49.02"E N32° 36' 42.03"E N15° 48' 16.29"E N8° 50' 56.67"E N17° 13' 12.36"W N40° 46' 11.69"W N62° 52' 20.23"W N18° 45' 44.40"W N9° 38' 46.42"E N21° 08' 41.16"E S56° 57' 02.75"E S17° 37' 15.92"W N83° 16' 45.17"W N5° 21' 30.84"E N22° 19' 53.00"E S4° 15' 24.20"W S5° 53' 54.87"W S11° 00' 04.14"E S89° 45' 06.13"E N59° 37' 53.69"E N85° 59' 36.73"E N0° 34' 05.27"E S89° 57' 57.49"E Radius Parcel Table Line #/Curve # L351 L352 L353 L354 L355 L356 C9 L357 L358 L359 L310 L311 L312 L313 L314 L315 L316 L317 L318 L319 L320 L321 L322 L323 L324 L325 Length 731.554 295.597 408.154 309.226 142.546 164.910 228.112 928.755 782.646 1061.786 1271.995 358.225 1428.801 797.070 413.192 381.740 85.186 44.204 156.591 185.898 383.712 113.640 214.265 327.646 1665.986 396.950 Direction/Delta N2° 22' 27.97"W N18° 30' 22.50"W N0° 26' 29.93"E S89° 59' 56.72"W N0° 23' 39.96"W N51° 55' 45.13"E 1.8408 S9° 27' 50.73"E S5° 48' 13.17"E N87° 39' 39.88"W S18° 13' 32.93"W S80° 27' 00.56"W N67° 47' 59.44"W S8° 09' 27.69"E N66° 40' 39.01"W N65° 08' 13.26"W S77° 13' 48.80"E S66° 07' 50.61"E N71° 37' 49.44"E S87° 45' 53.38"E N2° 07' 09.67"E N1° 26' 12.96"E N61° 32' 39.98"E S68° 57' 07.69"E N17° 35' 42.34"E N3° 02' 46.01"E Radius 7100.000 Parcel Table Line #/Curve # L326 L327 L328 L329 L330 L331 L332 L333 L334 L335 L336 L337 L338 Length 608.511 521.520 53.274 561.251 105.374 387.272 156.649 110.046 1858.465 973.079 750.901 890.957 424.500 Direction/Delta N21° 00' 20.78"E N65° 41' 27.19"W S68° 02' 25.87"W N66° 35' 29.20"W N11° 29' 42.25"W N70° 15' 14.87"W N77° 06' 49.74"W N62° 06' 37.60"W S77° 42' 46.65"E S20° 58' 07.37"W S41° 03' 57.63"E S69° 15' 57.80"E S19° 51' 49.20"W Radius BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_DD C-9.4 WATER QUALITY DESIGNATIONSFOREST/OPENSPACE METES AND BOUNDS BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_DD C-10.1 WATER QUANTITY SUMMARYWATER QUANTITY SUMMARY LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLD799 802 799 802 802798 805 804 805 801 800 799 803 803803802801800799BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5A STORMWATER DETAILSPOND 1A3:1 SIDE SLOPES LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 3:1 SIDE SLOPES DETENTION POND 1A CONVERSION SCALE: 1"=30' SEDIMENT TRAP CONVERSION: CONTRACTOR SHALL FILL BOTTOM OF BASIN TO DRAIN USING MATERIAL USED IN DAM CONSTRUCTION. GRADING SHOWN IS APPROXIMATE ONLY. CONTRACTOR TO USE AVAILABLE DAM MATERIAL FOR FILLING. NO IMPORT IS NEEDED FOR CONVERSION. CONTRACTOR TO EXCAVATE POND DAM TO PROMOTE POSITIVE DRAINAGE. REUSE EXISTING STONE FROM SPILLWAY FOR OUTLET PROTECTION LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD 797. 5 0 797. 5 0 797 796 795 794 793 792 797 796 795 794 793 792 8038 0 2 801 800 799 798 797 796 795 794 793 792 797. 5 0 797. 5 0 797 796 795 794 793 792 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5B STORMWATER DETAILSPOND 1BCONTRACTOR SHALL INSTALL 20' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 8' WIDE TO 28' WIDE. 4' CIRCULAR RISER (SEE DETAILS) (1) ANTI-SEEP COLLAR 6.2' x 6.2' CONCRETE MIN 4" THICK 3:1 SIDE SLOPES SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 3:1 SIDE SLOPES INV=791.5' CONTRACTOR SHALL INSTALL 4' WIDE, 18" DEEP VDOT CLASS 1 RIP RAP FROM DITCH OUTFALL TO BOTTOM OF POND BMP MAINTENANCE ROUTE 38' EMERGENCY SPILLWAY- 796 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP DETENTION POND - POND 1B SCALE: 1"=30' DAM ELEV: 797.5' SLOPE 3:1 POND BOTTOM- 792' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 1B NTS RISER SPILLWAY: 795' INV OUT 791.5' 40' - 30" @ 1.25% TOE OF DAM 792' POND RISER STRUCTURE EMERGENCY SPILLWAY: 796' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION 40' - 30" HDPE @ 1.25% DETENTION POND RISER STRUCTURE - POND 1B NOT TO SCALE SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 100 YEAR STORM (794.16') 10 YEAR STORM (792.80') (1) 30" HOLE (792.0') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5C STORMWATER DETAILSPOND 1CCONTRACTOR SHALL INSTALL 47' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 8' WIDE TO 29' WIDE. 3' CIRCULAR RISER (SEE DETAILS) 50'- 30" HDPE @ 2% (1) ANTI-SEEP COLLAR 6.2' x 6.2' CONCRETE MIN 4" THICK 3:1 SIDE SLOPES SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 3:1 SIDE SLOPES INV=791' BMP MAINTENANCE ROUTE 40' EMERGENCY SPILLWAY- 797.5 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP DETENTION POND - POND 1C SCALE: 1"=30' 3:1 SIDE SLOPES DAM ELEV: 797.5' SLOPE 3:1 POND BOTTOM- 792' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 1C NTS RISER SPILLWAY: 795' INV OUT 791' 50' - 30" @ 2.0% TOE OF DAM 792' POND RISER STRUCTURE EMERGENCY SPILLWAY: 796' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION DETENTION POND RISER STRUCTURE - POND 1C NOT TO SCALE SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. (1) 30" HOLE (792.0') 100 YEAR STORM (794.2') 10 YEAR STORM (792.83') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND.LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD 792 793 794 795 796 797 797 796 795 794 793 792 792 793 794 795 796 797 801800799798797796795794793792 LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD 809 808 807 806 805LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD806807808809810811812812.50812.50812811810809808807806818 815 813 810 808 806 826825823820817815 812 810 808 806 807 810 812 812.50 812.50 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5D STORMWATER DETAILSPOND 1D & POND 1ECONTRACTOR SHALL INSTALL 20' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 6' WIDE TO 22' WIDE. 4' CIRCULAR RISER (SEE DETAILS) (1) ANTI-SEEP COLLAR 6.2' x 6.2' CONCRETE MIN 4" THICK INV=805' 32' EMERGENCY SPILLWAY - 811' TO BE ARMORED WITH VDOT CLASS 1 RIP RAP DETENTION POND - POND 1D CONVERSION SCALE: 1"=30' DAM ELEV: 812.5' SLOPE 3:1 POND BOTTOM - 806' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 1E NTS RISER SPILLWAY: 810' INV OUT 805' 50' - 24" @ 2.0% TOE OF DAM 806' POND RISER STRUCTURE EMERGENCY SPILLWAY: 811' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION DETENTION POND - POND 1E SCALE: 1"=30' SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 50'- 24" HDPE @ 2% DETENTION POND RISER STRUCTURE - POND 1E NOT TO SCALE SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. (1) 24" HOLE (806') 100 YEAR STORM (808.67') 10 YEAR STORM (806.9') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. SEDIMENT TRAP CONVERSION: CONTRACTOR SHALL FILL BOTTOM OF BASIN TO DRAIN USING MATERIAL USED IN DAM CONSTRUCTION. GRADING SHOWN IS APPROXIMATE ONLY. CONTRACTOR TO USE AVAILABLE DAM MATERIAL FOR FILLING. NO IMPORT IS NEEDED FOR CONVERSION. CONTRACTOR SHALL INSTALL 32' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 15' WIDE TO 37' WIDE. LD LD LDLDLDLD LD LD LD LD LD LD LD LDLDLDLD810 812 814 810 812 814 814 812 807 805 801 803 810 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5E STORMWATER DETAILSPOND 1F3:1 SIDE SLOPES SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 3:1 SIDE SLOPES DETENTION POND - POND 1F SCALE: 1"=30' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 SEDIMENT TRAP CONVERSION: CONTRACTOR SHALL FILL BOTTOM OF BASIN TO DRAIN USING MATERIAL USED IN DAM CONSTRUCTION. GRADING SHOWN IS APPROXIMATE ONLY. CONTRACTOR TO USE AVAILABLE DAM MATERIAL FOR FILLING. NO IMPORT IS NEEDED FOR CONVERSION. CONTRACTOR TO EXCAVATE POND DAM TO PROMOTE POSITIVE DRAINAGE. REUSE EXISTING STONE FROM SPILLWAY FOR OUTLET PROTECTION LD LD LDLDLD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD 797 800 803 805 808 808 803 805 803 805 808 808 809 808 808 805 802 800 808808796 798 800 802 800 800 798 798 795 793 793 795 797 797 795 793 792 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5F STORMWATER DETAILSPOND 1G & POND 1HCONTRACTOR SHALL INSTALL 14' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 4' WIDE TO 16' WIDE. 4' CIRCULAR RISER (SEE DETAILS) (1) ANTI-SEEP COLLAR 5.4' x 5.4' CONCRETE MIN 4" THICK 3:1 SIDE SLOPES SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 3:1 SIDE SLOPES INV=797' DAM ELEV: 808' POND BOTTOM - 803' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 1G NTS RISER SPILLWAY: 805.5' INV OUT 797' 50' - 15" @ 12.0% TOE OF DAM 797' POND RISER STRUCTURE LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION 3:1 SLOPE DETENTION POND - POND 1G & POND 1H CONVERSION SCALE: 1"=30' 50'- 15" HDPE @ 12% 3:1 SIDE SLOPES 3:1 SIDE SLOPES POND 1G POND 1H SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. DETENTION POND RISER STRUCTURE - POND 1G NOT TO SCALE 100 YEAR STORM (804.3') (1) 15" HOLE (803.0') 10 YEAR STORM (803.45') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. SEDIMENT TRAP CONVERSION: CONTRACTOR SHALL FILL BOTTOM OF BASIN TO DRAIN USING MATERIAL USED IN DAM CONSTRUCTION. GRADING SHOWN IS APPROXIMATE ONLY. CONTRACTOR TO USE AVAILABLE DAM MATERIAL FOR FILLING. NO IMPORT IS NEEDED FOR CONVERSION. INV=796' INV=794' 70'- 15" HDPE @ 2.86% CONTRACTOR SHALL INSTALL 8' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 4' WIDE TO 10' WIDE. CONTRACTOR TO EXCAVATE POND DAM TO PROMOTE POSITIVE DRAINAGE. REUSE EXISTING STONE FROM SPILLWAY FOR OUTLET PROTECTION LDLD LD LD LD LD LD LD LD LD LD LD LDLDLD790 790 789 788 787 789 788 787 786 785 790 789 788 787 786 785 790 790 789 788 787 786785 LD LD LD LD LD LD LD LD LD LD LD LD LD L D LDLDLDLDLDLDLDLDLDLDLD77 1 77 2773774 775 776 777 778 778 777 776 775 774 773 772 778778800 798 795 792 790 787 785 783 780 777 775 772 778778775772778 778 775 772 773775778BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5G STORMWATER DETAILSPOND 1I & POND 1JCONTRACTOR SHALL INSTALL 12' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 4' WIDE TO 14' WIDE. 3' CIRCULAR RISER (SEE DETAILS) (1) ANTI-SEEP COLLAR 4.5' x 4.5' CONCRETE MIN 4" THICK 3:1 SIDE SLOPES SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 3:1 SIDE SLOPES INV=784' DAM ELEV: 790' POND BOTTOM - 785' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 1I NTS RISER SPILLWAY: 787.5' INV OUT 784' 50' - 15" @ 2.0% TOE OF DAM 785' POND RISER STRUCTURE LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION 3:1 SLOPE DETENTION POND - POND 1I SCALE: 1"=30' 50'- 15" HDPE @ 2% DETENTION POND - POND 1J SCALE: 1"=30' EMERGENCY SPILLWAY: 788.5' 8' EMERGENCY SPILLWAY- 788.5 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP CONTRACTOR SHALL INSTALL 22' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 6' WIDE TO 24' WIDE. SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 3:1 SIDE SLOPES 3:1 SIDE SLOPES 3:1 SIDE SLOPES 4' CIRCULAR RISER (SEE DETAILS) (1) ANTI-SEEP COLLAR 6' x 6' CONCRETE MIN 4" THICK INV=771' 50'- 24" HDPE @ 2% DAM ELEV: 778' POND BOTTOM - 772' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 1J NTS RISER SPILLWAY: 775' INV OUT 771' 50' - 24" @ 2.0% TOE OF DAM 772' POND RISER STRUCTURE 3:1 SLOPE EMERGENCY SPILLWAY: 776.5' 30' EMERGENCY SPILLWAY- 776.5 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP 100 YEAR STORM (786.73') (1) 15" HOLE (785.0') 10 YEAR STORM (785.63') 100 YEAR STORM (774.38') (1) 24" HOLE (772') 10 YEAR STORM (772.86') DETENTION POND RISER STRUCTURE - POND 1J NOT TO SCALE SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. DETENTION POND RISER STRUCTURE - POND 1I NOT TO SCALE MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. LD LDLDLDLDLDLDLD LD LD LD LD LDLDLDL D LDL D L D 828 827 826 825 824 823 822 821 820 819 818 817 816 811 813 815 817 819 821 821 816 821821820818816817816818820820 818 LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD781 780 779 778779780781782783783782781780780 782 781.50782 784 785 787 790 792 794 783 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5H STORMWATER DETAILSPOND 1K & POND 1LCONTRACTOR SHALL INSTALL 12' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 4' WIDE TO 14' WIDE. 3' CIRCULAR RISER (SEE DETAILS) (1) ANTI-SEEP COLLAR 4.5' x 4.5' CONCRETE MIN 4" THICK 3:1 SIDE SLOPES SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER INV=810' DAM ELEV: 821' POND BOTTOM - 816' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 1K NTS RISER SPILLWAY: 818.5' INV OUT 810' 60' - 15" @ 10.0% TOE OF DAM 811' POND RISER STRUCTURE LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION 3:1 SLOPE DETENTION POND - POND 1K SCALE: 1"=30' 60'- 15" HDPE @ 10% DETENTION POND - POND 1L SCALE: 1"=30' EMERGENCY SPILLWAY: 819.5' 8' EMERGENCY SPILLWAY- 819.5 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP CONTRACTOR SHALL INSTALL 12' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 5' WIDE TO 14' WIDE. SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 3:1 SIDE SLOPES 3:1 SIDE SLOPES 3:1 SIDE SLOPES 3' CIRCULAR RISER (SEE DETAILS) (1) ANTI-SEEP COLLAR 5' x 5' CONCRETE MIN 4" THICK INV=779' 40'- 18" HDPE @ 2.5% DAM ELEV: 785' POND BOTTOM - 780' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 1L NTS RISER SPILLWAY: 782.5' INV OUT 779' 40' - 18" @ 2.5% TOE OF DAM 779' POND RISER STRUCTURE 3:1 SLOPE EMERGENCY SPILLWAY: 783.5' 12' EMERGENCY SPILLWAY- 783.5 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP 3:1 SIDE SLOPES 100'- 18" HDPE @ 1% INV=780.5'INV=781.5' 3:1 SIDE SLOPES DETENTION POND RISER STRUCTURE - POND 1L NOT TO SCALE 100 YEAR STORM (781.85') (1) 18" HOLE (780') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (780.62') 100 YEAR STORM (817.6') (1) 15" HOLE (816') 10 YEAR STORM (816.53') DETENTION POND RISER STRUCTURE - POND 1K NOT TO SCALE MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. CONTRACTOR SHALL INSTALL 12' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 4.5' WIDE TO 13.5' WIDE. LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD779 780 781 782 783 785 785 783 782 781 780 779.50 788783780779.50779.50781783785BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5I STORMWATER DETAILSPOND 1MDAM ELEV: 785' POND BOTTOM - 779.5' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 1M NTS RISER SPILLWAY: 782.5' INV OUT 779' 40' - 30" @ 1.25% TOE OF DAM 811' POND RISER STRUCTURE LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION 3:1 SLOPE DETENTION POND - POND 1M SCALE: 1"=30' EMERGENCY SPILLWAY: 783.5' CONTRACTOR SHALL INSTALL 22' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 8' WIDE TO 25' WIDE. SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 3:1 SIDE SLOPES 3:1 SIDE SLOPES 3:1 SIDE SLOPES 5' CIRCULAR RISER (SEE DETAILS)(1) ANTI-SEEP COLLAR 5' x 5' CONCRETE MIN 4" THICK 40'- 30" HDPE @ 1.25% 40' EMERGENCY SPILLWAY- 783.5 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP INV=779' DETENTION POND RISER STRUCTURE - POND 1M NOT TO SCALE 100 YEAR STORM (781.80') (1) 30" HOLE (779.5') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (780.35') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. LD LDLDLDLD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDINV 3 823 824 825 826 827 828 828 827 826 825 824 823 828 827 826 825 824 823 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5J STORMWATER DETAILSPOND 1NDAM ELEV: 828' POND BOTTOM - 823' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 1N NTS RISER SPILLWAY: 825.5' INV OUT 822' 40' - 18" @ 2.5% TOE OF DAM 823' POND RISER STRUCTURE INV=822' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION 3:1 SLOPE DETENTION POND - POND 1N SCALE: 1"=30' EMERGENCY SPILLWAY: 826.5' CONTRACTOR SHALL INSTALL 22' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 8' WIDE TO 25' WIDE. SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 3:1 SIDE SLOPES 3:1 SIDE SLOPES 3' CIRCULAR RISER (SEE DETAILS) (1) ANTI-SEEP COLLAR 4' x 4' CONCRETE MIN 4" THICK 40'- 18" HDPE @ 2.5% 12' EMERGENCY SPILLWAY- 826.5 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP DETENTION POND RISER STRUCTURE - POND 1N NOT TO SCALE 100 YEAR STORM (824.66') (1) 18" HOLE (823') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (823.61') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. LD LD LD LD LD LD LD LD LD LD LD LD LDLDLD LDLDLDLDLDLDLDLDLDLDLDLDLD815 814 8 1 3 8178178168158148138128 1 4 81 5 81 7 81 7815 812 812815817817 815 812 815 813 810 810 811 813 815 815BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5K STORMWATER DETAILSPOND 1-1ADAM ELEV: 817' POND BOTTOM - 812' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 1-1A NTS RISER SPILLWAY: 814.5' INV OUT 810' 70' - 18" @ 2.86% TOE OF DAM 813' POND RISER STRUCTURE INV=810' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION 3:1 SLOPE DETENTION POND - POND 1-1A SCALE: 1"=30' EMERGENCY SPILLWAY: 815.5' CONTRACTOR SHALL INSTALL 18' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 5' WIDE TO 20' WIDE. SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 3:1 SIDE SLOPES 3:1 SIDE SLOPES 3' CIRCULAR RISER (SEE DETAILS) (1) ANTI-SEEP COLLAR 4.25' x 4.25' CONCRETE MIN 4" THICK 70'- 18" HDPE @ 2.86% 14' EMERGENCY SPILLWAY- 815.5 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP DETENTION POND RISER STRUCTURE - POND 1-1A NOT TO SCALE 100 YEAR STORM (813.77') (1) 18" HOLE (812.0') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (812.61') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. LDLDLDLDLDLDLDLDINV 9815814813 817 815815813810809808807808 809 810 811 812 813 814 815 815 814 813 812 811 810 809 809 810 811 812 813 814 815 810811813815815813811809815809810812BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5L STORMWATER DETAILSPOND 1-1BDAM ELEV: 815.5' POND BOTTOM - 809' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 1-1B NTS RISER SPILLWAY: 812.5' INV OUT 808' (2) 40' - 24" @ 2.5% TOE OF DAM 809' POND RISER STRUCTURE (TYP. OF 2) INV=808' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION 3:1 SLOPE DETENTION POND - POND 1-1B SCALE: 1"=30' EMERGENCY SPILLWAY: 813.5' CONTRACTOR SHALL INSTALL 22' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 16' WIDE TO 34' WIDE. SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 3:1 SIDE SLOPES 3:1 SIDE SLOPES (2) 4' CIRCULAR RISER (SEE DETAILS) (1) ANTI-SEEP COLLAR 5.75' x 5.75' PER PIPE CONCRETE MIN 4" THICK (2) 40'- 24" HDPE @ 2.5% 36' EMERGENCY SPILLWAY- 813.5 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP 815.5'815.5' 815.5' 815.5' 815.5' 815.5' 815.5' DETENTION POND RISER STRUCTURE - POND 1-1B NOT TO SCALE 100 YEAR STORM (811.34') (1) 24" HOLE PER RISER (809.0') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (809.8') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD 807810808807808 809 810 811 812 813 814 815 815 814 813 812 811 810 809 807810815815813810808808810812815808 809 810 811 812 813 814 815 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5M STORMWATER DETAILSPOND 1-1CDAM ELEV: 815.5' POND BOTTOM - 808' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 1-1C NTS RISER SPILLWAY: 812.5' INV OUT 807' (2) 50' - 30" @ 2% TOE OF DAM 808' POND RISER STRUCTURE (TYP. OF 2) INV=807' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION 3:1 SLOPE DETENTION POND - POND 1-1C SCALE: 1"=30' EMERGENCY SPILLWAY: 813.5' CONTRACTOR SHALL INSTALL 24' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 16' WIDE TO 35' WIDE. SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 3:1 SIDE SLOPES 3:1 SIDE SLOPES (2) 5' CIRCULAR RISER (SEE DETAILS) (1) ANTI-SEEP COLLAR 6.5' x 6.5' PER PIPE CONCRETE MIN 4" THICK (2) 50'- 30" HDPE @ 2% 28' EMERGENCY SPILLWAY- 813.5 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP 815.5' 815.5' 815.5' 815.5' 815.5' 815.5'815.5'815.5' DETENTION POND RISER STRUCTURE - POND 1-1C NOT TO SCALE 100 YEAR STORM (811.12') (1) 30" HOLE PER RISER (808') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (809.8') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. LDLDLDLDLDLDLDLDLDLD835 836 837 834 LDLDLDLDLDLDLDLD824 825 827 830 831 831 830 827 827 828829830831832 834833 835 836 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5N STORMWATER DETAILSPOND 1-3A & 7C LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 DETENTION POND - POND 1-3A CONVERSION SCALE: 1"=30' DETENTION POND - POND 7C SCALE: 1"=30' DAM ELEV: 831' POND BOTTOM - 827' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 7C NTS RISER SPILLWAY: 829' INV OUT 824' 40' - 15" @ 7.5% TOE OF DAM 825' POND RISER STRUCTURE NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION 3:1 SLOPE SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. DETENTION POND RISER STRUCTURE - POND 7C NOT TO SCALE MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. (1) 4" HOLE (827') (1) 6" HOLE (828') 100 YEAR STORM (828.35') 10 YEAR STORM (827.42') INV=824' CONTRACTOR SHALL INSTALL 8' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 4' WIDE TO 10' WIDE. SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 3:1 SIDE SLOPES 3' CIRCULAR RISER (SEE DETAILS) (1) ANTI-SEEP COLLAR 5.75' x 5.75' CONCRETE MIN 4" THICK 40'- 15" HDPE @ 7.5% 3:1 SIDE SLOPES SEDIMENT TRAP CONVERSION: CONTRACTOR SHALL FILL BOTTOM OF BASIN TO DRAIN USING MATERIAL USED IN DAM CONSTRUCTION. GRADING SHOWN IS APPROXIMATE ONLY. CONTRACTOR TO USE AVAILABLE DAM MATERIAL FOR FILLING. NO IMPORT IS NEEDED FOR CONVERSION. LDLDLDLDLDLDLDLDLD834 833 832 831 831 833 LDLDLDLDLDLDLDLDLDLDLD821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 835 834 833 832 831 830 844 842 840 838 835 832 830 842840838835832830832 835 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5O STORMWATER DETAILSPOND 6A & 7ADAM ELEV: 835' POND BOTTOM - 830' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 7A NTS RISER SPILLWAY: 832.5' INV OUT 820' 70' - 15" @ 14.3% TOE OF DAM 814' POND RISER STRUCTURE INV=820' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION 3:1 SLOPE DETENTION POND - POND 7A SCALE: 1"=30' EMERGENCY SPILLWAY: 833.5' CONTRACTOR SHALL INSTALL 12' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 4' WIDE TO 14' WIDE. SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 3:1 SIDE SLOPES 3:1 SIDE SLOPES 3' CIRCULAR RISER (SEE DETAILS) (1) ANTI-SEEP COLLAR 5.75' x 5.75' CONCRETE MIN 4" THICK 70'- 15" HDPE @ 14.3% DETENTION POND - POND 6A CONVERSION SCALE: 1"=30' 3:1 SIDE SLOPES 3:1 SIDE SLOPES 8' EMERGENCY SPILLWAY- 833.5 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. DETENTION POND RISER STRUCTURE - POND 7A NOT TO SCALE MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. (1) 3" HOLE (830') (1) 6" HOLE (831.5') 100 YEAR STORM (831.59') 10 YEAR STORM (830.45') SEDIMENT TRAP CONVERSION: CONTRACTOR SHALL FILL BOTTOM OF BASIN TO DRAIN USING MATERIAL USED IN DAM CONSTRUCTION. GRADING SHOWN IS APPROXIMATE ONLY. CONTRACTOR TO USE AVAILABLE DAM MATERIAL FOR FILLING. NO IMPORT IS NEEDED FOR CONVERSION. CONTRACTOR TO EXCAVATE POND DAM TO PROMOTE POSITIVE DRAINAGE. REUSE EXISTING STONE FROM SPILLWAY FOR OUTLET PROTECTION LDLDLDLDLDLDLDLDLDLDLD825 827 829 830 830 828 825 825 827 830 833 835 837 840841 830 830 LDLDLDLDLDLDLDLD84 0 84 1 84 2 84 3 84 3 84 2 84 1 84 0 83 9 . 5 0 844 843 842 841 840 839.50 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5P STORMWATER DETAILSPOND 7B & 8A LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 DETENTION POND - POND 8A SCALE: 1"=30' DETENTION POND - POND 7B SCALE: 1"=30' 3:1 SIDE SLOPES 3:1 SIDE SLOPES 3:1 SIDE SLOPES 3:1 SIDE SLOPES SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER DAM ELEV: 830' POND BOTTOM - 825' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 7B NTS RISER SPILLWAY: 827.5' INV OUT 824' 40' - 15" @ 2.5% TOE OF DAM 825' POND RISER STRUCTURE NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION 3:1 SLOPE DETENTION POND RISER STRUCTURE - POND 7B NOT TO SCALE 100 YEAR STORM (827.26') (1) 3" HOLE (825') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. (1) 6" HOLE (826') 10 YEAR STORM (826.03') DAM ELEV: 843' POND BOTTOM - 839.5' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 8A NTS RISER SPILLWAY: 841.5' INV OUT 839' 30' - 15" @ 1.67% TOE OF DAM 840' POND RISER STRUCTURE 3:1 SLOPE DETENTION POND RISER STRUCTURE - POND 8A NOT TO SCALE 100 YEAR STORM (840.48') (1) 2" HOLE (839.5') (1) 6" HOLE (840.5') 10 YEAR STORM (839.8') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. INV=820' CONTRACTOR SHALL INSTALL 8' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 4' WIDE TO 10' WIDE. 3' CIRCULAR RISER (SEE DETAILS) (1) ANTI-SEEP COLLAR 5.75' x 5.75' CONCRETE MIN 4" THICK 40'- 15" HDPE @ 2.5% CONTRACTOR SHALL INSTALL 8' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 4' WIDE TO 10' WIDE.INV=839' 30'- 15" HDPE @ 1.67% 3' CIRCULAR RISER (SEE DETAILS) LDLDLDLDLDLDLDLDLDLDLD833 833 835 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5Q STORMWATER DETAILSPOND 11A & 11B LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 DETENTION POND - POND 11A & 11B CONVERSION SCALE: 1"=30' SEDIMENT TRAP CONVERSION: CONTRACTOR SHALL FILL BOTTOM OF BASIN TO DRAIN USING MATERIAL USED IN DAM CONSTRUCTION. GRADING SHOWN IS APPROXIMATE ONLY. CONTRACTOR TO USE AVAILABLE DAM MATERIAL FOR FILLING. NO IMPORT IS NEEDED FOR CONVERSION. LDLDLDLDLDLDLDLD856 855 854 853 LDLDLDLDLDLDLDLDLDLDLD848849850851 851 850 849 848 848 849 850 851 850 851 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5R STORMWATER DETAILSPOND 12A & 13A LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 DETENTION POND - POND 12A CONVERSION SCALE: 1"=30' 3:1 SIDE SLOPES 3:1 SIDE SLOPES DETENTION POND - POND 13A CONVERSION SCALE: 1"=30' SEDIMENT TRAP CONVERSION: CONTRACTOR SHALL FILL BOTTOM OF BASIN TO DRAIN USING MATERIAL USED IN DAM CONSTRUCTION. GRADING SHOWN IS APPROXIMATE ONLY. CONTRACTOR TO USE AVAILABLE DAM MATERIAL FOR FILLING. NO IMPORT IS NEEDED FOR CONVERSION. CONTRACTOR TO EXCAVATE POND DAM TO PROMOTE POSITIVE DRAINAGE. REUSE EXISTING STONE FROM SPILLWAY FOR OUTLET PROTECTION SEDIMENT TRAP CONVERSION: CONTRACTOR SHALL FILL BOTTOM OF BASIN TO DRAIN USING MATERIAL USED IN DAM CONSTRUCTION. GRADING SHOWN IS APPROXIMATE ONLY. CONTRACTOR TO USE AVAILABLE DAM MATERIAL FOR FILLING. NO IMPORT IS NEEDED FOR CONVERSION. LDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD L D L D LDLDLD818817 816 815 814 813 812 811 810 809 808 807 806 805 804 803 802 801.50 802803804805806807808 808807806805804 803802 801. 5 0808808802 809807805803801.50LDLDLDLDLDLDLD LD LD LD LD LD LD LD LD827826825824823822828827825822 818 8 2 0822 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5S STORMWATER DETAILSPOND 16ACONTRACTOR SHALL INSTALL 20' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 16' WIDE TO 31' WIDE. (2) 5' CIRCULAR RISER (SEE DETAILS) 3:1 SIDE SLOPES SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 3:1 SIDE SLOPES INV=801' 24' EMERGENCY SPILLWAY- 806 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP DETENTION POND - POND 16A SCALE: 1"=30' DAM ELEV: 808' SLOPE 3:1 POND BOTTOM- 801.5' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 16A NTS RISER SPILLWAY: 805' INV OUT 801' 50' - 30" @ 1% TOE OF DAM 802' POND RISER STRUCTURE EMERGENCY SPILLWAY: 806' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION (2) 50' - 30" HDPE @ 1% (1) ANTI-SEEP COLLAR 5.75' x 5.75' PER PIPE CONCRETE MIN 4" THICK SUMP 15A - DIVERSION TO POND 16A SCALE: 1"=30' INV=822' INV=817.8' 280' - 30" HDPE @ 1.5% DETENTION POND RISER STRUCTURE - POND 16A NOT TO SCALE 100 YEAR STORM (804.41') (1) 30" HOLE PER RISER (801.5') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (802.51') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. CONTRACTOR SHALL INSTALL 18' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 6' WIDE TO 20' WIDE. LDLDLDLD LD LD LD LD LD LD L D L D L D L D 828 825 822 820 818 815 812 808 810 816 815 813 816 812 815 807 810 816 815 812 823 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D D-5T STORMWATER DETAILSPOND 17A LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 3:1 SIDE SLOPES 3:1 SIDE SLOPES DETENTION POND - POND 17A SCALE: 1"=30' SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER SEDIMENT TRAP CONVERSION: CONTRACTOR SHALL FILL BOTTOM OF BASIN TO DRAIN USING MATERIAL USED IN DAM CONSTRUCTION. GRADING SHOWN IS APPROXIMATE ONLY. CONTRACTOR TO USE AVAILABLE DAM MATERIAL FOR FILLING. NO IMPORT IS NEEDED FOR CONVERSION. CONTRACTOR TO EXCAVATE POND DAM TO PROMOTE POSITIVE DRAINAGE. REUSE EXISTING STONE FROM SPILLWAY FOR OUTLET PROTECTION LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD L D LDLDLDLDLD 24 756 757 758 759 760 761 762 764 763 762 761 760 759 758 757 756.50 760 756.50758760762764 755762760758760 762 764 762 760 758756.50 774 772 770 76 8 76 57627 6 0 7 5 8 7 5 6 . 5 0 758759760761762 770 768 765 765 764 760 757 LD LD LD LD LD LD LD LD LD LD LDLDLDLD778 779 780 781 782 783 783 782 781 786 785 784 783 782 781 780 779 778 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D D-5U STORMWATER DETAILSPOND 18BCONTRACTOR SHALL INSTALL 20' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 16' WIDE TO 31' WIDE. (2) 5' CIRCULAR RISER (SEE DETAILS) 3:1 SIDE SLOPES SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 3:1 SIDE SLOPES INV=756' 26' EMERGENCY SPILLWAY- 762 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP DETENTION POND - POND 18B SCALE: 1"=30' DAM ELEV: 764' SLOPE 3:1 POND BOTTOM- 756.5' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 18B NTS RISER SPILLWAY: 761' INV OUT 756' (2) 50' - 30" @ 1% TOE OF DAM 757' POND RISER STRUCTURE (TYP. OF 2) EMERGENCY SPILLWAY: 762' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION (2) 50' - 30" HDPE @ 1% (1) ANTI-SEEP COLLAR 6.5' x 6.5' PER PIPE CONCRETE MIN 4" THICK SUMP 18A - DIVERSION TO POND 18B SCALE: 1"=30' INV=778' INV=776' 100' - 30" HDPE @ 2% 3:1 SIDE SLOPES 3:1 SIDE SLOPES 3:1 SIDE SLOPES DETENTION POND RISER STRUCTURE - POND 18B NOT TO SCALE 100 YEAR STORM (760.89') (1) 30" HOLE PER RISER (756.5') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (758.24') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. CONTRACTOR SHALL INSTALL 18' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 8' WIDE TO 21' WIDE. LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD770 771 772 773 774 775 776 777777.50 777.50777 776 775 774 773 772 771 778 776 775 774 773 772 771 779777775773771779777.50777 776 775 774 773 772 771 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5V STORMWATER DETAILSPOND 19ACONTRACTOR SHALL INSTALL 22' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 12' WIDE TO 31' WIDE. (2) 4' CIRCULAR RISER (SEE DETAILS) 3:1 SIDE SLOPES SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 3:1 SIDE SLOPES INV=770' 24' EMERGENCY SPILLWAY- 806 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP DETENTION POND - POND 19A SCALE: 1"=30' DAM ELEV: 777.5' SLOPE 3:1 POND BOTTOM- 771' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 19A NTS RISER SPILLWAY: 774.5' INV OUT 770' (2) 50' - 24" @ 2% TOE OF DAM 771' POND RISER STRUCTURE (TYP. OF 2) EMERGENCY SPILLWAY: 775.5' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION (2) 50' - 24" HDPE @ 2% (1) ANTI-SEEP COLLAR 5.5' x 5.5' PER PIPE CONCRETE MIN 4" THICK 3:1 SIDE SLOPES 3:1 SIDE SLOPES DETENTION POND RISER STRUCTURE - POND 19A NOT TO SCALE 100 YEAR STORM (774.62') (1) 24" HOLE PER RISER (771') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (772.42') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. FPFPFPOHPOHPOHPOHPOHPOHPOHPLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD731 731730729728727 726. 5 0 73 2 73 3 7 2 6 72 7 72 8729 730 731 731 726.50 728 730 731LDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD780 781 782 783 784 784 783 782 781 780 780 782 784 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D D-5W STORMWATER DETAILSPOND 23A & 25A3:1 SIDE SLOPES SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 3:1 SIDE SLOPES DETENTION POND 23A SCALE: 1"=30' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 DETENTION POND RISER STRUCTURE - POND 23A NOT TO SCALE SLOPE 3:1 POND BOTTOM - 726.5' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 23A NTS RISER SPILLWAY: 729' 100 YEAR STORM (729.87') INV OUT 726' 50' - 15" @ 1% TOE OF DAM 727' POND RISER STRUCTURE EMERGENCY SPILLWAY: 730' EXISTING GRADE (1) 2" HOLE (726.5') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. (1) 6" HOLE (728') 10 YEAR STORM (729.07') NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION DAM ELEV: 731' CONTRACTOR SHALL INSTALL 8' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 4' WIDE TO 10' WIDE. 3' CIRCULAR RISER (SEE DETAILS) INV=726' 16' EMERGENCY SPILLWAY- 730 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP 50' - 15" HDPE @ 1% (1) ANTI-SEEP COLLAR 5.5' x 5.5' PER PIPE CONCRETE MIN 4" THICK MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. DETENTION POND 25A SCALE: 1"=30' DETENTION POND RISER STRUCTURE - POND 25A NOT TO SCALE SLOPE 3:1 POND BOTTOM - 780' SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. RISER SPILLWAY: 782' 100 YEAR STORM (781.96') INV OUT 779' 30' - 15" @ 3.33% TOE OF DAM 780' POND RISER STRUCTURE EMERGENCY SPILLWAY: 783' (1) 2" HOLE (780') (1) 6" HOLE (781') 10 YEAR STORM (781.04') DAM ELEV: 784' CONTRACTOR SHALL INSTALL 8' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 4' WIDE TO 10' WIDE. (1) ANTI-SEEP COLLAR 5.5' x 5.5' PER PIPE CONCRETE MIN 4" THICK 50' - 15" HDPE @ 1% 10' EMERGENCY SPILLWAY - 783' TO BE ARMORED WITH VDOT CLASS 1 RIP RAP * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION DETENTION POND DETAIL - POND 25A NTS SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER 3:1 SIDE SLOPES 3' CIRCULAR RISER (SEE DETAILS) INV=779' OHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHP 725 731 730 729 728 727 726 725726727728729731731730729730731731 731 730 728 726 731731732730729732733734735BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5X STORMWATER DETAILSPOND 27ACONTRACTOR SHALL INSTALL 12' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 4' WIDE TO 14' WIDE. 3' CIRCULAR RISER (SEE DETAILS) 3:1 SIDE SLOPES SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER INV=725' DETENTION POND - POND 27A SCALE: 1"=30' DAM ELEV: 731' SLOPE 3:1 POND BOTTOM- 726' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 27A NTS RISER SPILLWAY: 728.5' INV OUT 725' 70' - 15" @ 1.4% TOE OF DAM 726' POND RISER STRUCTURE LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION 70' - 15" HDPE @ 1.4% (1) ANTI-SEEP COLLAR 4.25' x 4.25' CONCRETE MIN 4" THICK 3:1 SIDE SLOPES 3:1 SIDE SLOPES DETENTION POND RISER STRUCTURE - POND 27A NOT TO SCALE 100 YEAR STORM (728.93') (1) 15" HOLE (726') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (727.92') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. OHP OHP OHP OHP OHP OHP OHP OHP LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLD LD724725726727728729730 730729728727726725724723.50 730730728725723.50730 730 728 725 723.50 730729728727726725724723.50BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5Y STORMWATER DETAILSPOND 27BCONTRACTOR SHALL INSTALL 22' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 16' WIDE TO 33' WIDE. (2) 5' CIRCULAR RISER (SEE DETAILS) 3:1 SIDE SLOPES SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER INV=723' 26' EMERGENCY SPILLWAY- 728 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP DETENTION POND - POND 27B SCALE: 1"=30' DAM ELEV: 730' SLOPE 3:1 POND BOTTOM- 723.5' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 27B NTS RISER SPILLWAY: 727' INV OUT 723' (2) 50' - 30" @ 1% TOE OF DAM 724' POND RISER STRUCTURE (TYP. OF 2) EMERGENCY SPILLWAY: 728' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION (2) 50' - 30" HDPE @ 1% (1) ANTI-SEEP COLLAR 5.75' x 5.75' PER PIPE CONCRETE MIN 4" THICK 3:1 SIDE SLOPES 3:1 SIDE SLOPES DETENTION POND RISER STRUCTURE - POND 27B NOT TO SCALE 100 YEAR STORM (728.31') (1) 30" HOLE PER RISER (723.5') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (725.86') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD7 5 6 7 5 7 7 5 8 7 5 9 7 6 0 7 6 1 7 6 2 7 6 2 7 6 1 7 6 0 7 5 9 7 5 8 7 5 7 7 5 6 756757758759760761762762761760759758757756755754.50 755 756 757 758 759 760 761 762 762 761 760 759 758 757 756 755 754.50 7 7 2 7 7 0 767765763760758755754.50762 761 760 759 758 757 756 762 761 760 759 758 757 756 755754.50 762 762 760 756 762760758756BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5Z STORMWATER DETAILSPOND 27C & 27DCONTRACTOR SHALL INSTALL 20' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 12' WIDE TO 28' WIDE. (2) 4' CIRCULAR RISER (SEE DETAILS) 3:1 SIDE SLOPES SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER INV=754' 22' EMERGENCY SPILLWAY- 760 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP DETENTION POND - POND 27C SCALE: 1"=30' DAM ELEV: 762' SLOPE 3:1 POND BOTTOM- 756' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 27C NTS RISER SPILLWAY: 759' INV OUT 755' (2) 50' - 30" @ 2% TOE OF DAM 756' POND RISER STRUCTURE (TYP. OF 2) EMERGENCY SPILLWAY: 760' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION (2) 50' - 24" HDPE @ 1% (1) ANTI-SEEP COLLAR 6' x 6' PER PIPE CONCRETE MIN 4" THICK 3:1 SIDE SLOPES 3:1 SIDE SLOPES DAM ELEV: 762' SLOPE 3:1 POND BOTTOM- 754.5' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 27D NTS RISER SPILLWAY: 759' INV OUT 754' (2) 50' - 24" @ 1% TOE OF DAM 755' POND RISER STRUCTURE (TYP. OF 2) EMERGENCY SPILLWAY: 760' DETENTION POND - POND 27D SCALE: 1"=30' (1) ANTI-SEEP COLLAR 5.5' x 5.5' PER PIPE CONCRETE MIN 4" THICK (2) 4' CIRCULAR RISER (SEE DETAILS) (2) 50' - 30" HDPE @ 2% INV=755' CONTRACTOR SHALL INSTALL 18' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 16' WIDE TO 30' WIDE. 18' EMERGENCY SPILLWAY- 760 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP DETENTION POND RISER STRUCTURE - POND 27C NOT TO SCALE 100 YEAR STORM (759.92') (1) 30" HOLE PER RISER (756') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (757.82') DETENTION POND RISER STRUCTURE - POND 27D NOT TO SCALE 100 YEAR STORM (760.18') (1) 24" HOLE PER RISER (754.5') 10 YEAR STORM (757.35') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. LDLDLDLDLDLDLDLDLD753 755 757 760 760 758 755 755 756 757 758 759 760 76 1 76 3 76 5 LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD755 756 757 758 758 757 756 755 754.50 754.50755 756 757 758 761 76 1 763 762 75476 0 7 6 0 7 6 0 759 759 760 760 759 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5AA STORMWATER DETAILSPOND 28A & 28BCONTRACTOR SHALL INSTALL 14' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 6' WIDE TO 16' WIDE. 3' CIRCULAR RISER (SEE DETAILS) SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER INV=754' DETENTION POND - POND 28A SCALE: 1"=30' DAM ELEV: 760' SLOPE 3:1 POND BOTTOM- 755' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 28A NTS RISER SPILLWAY: 757.5' INV OUT 753' 40' - 15" @ 5% TOE OF DAM 754' POND RISER STRUCTURE LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION 40' - 15" HDPE @ 1.25% (1) ANTI-SEEP COLLAR 5' x 5' PER PIPE CONCRETE MIN 4" THICK 3:1 SIDE SLOPES 3:1 SIDE SLOPES DAM ELEV: 760' SLOPE 3:1 POND BOTTOM- 754.5' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 28B NTS RISER SPILLWAY: 757.5' INV OUT 754' 40' - 15" @ 1.25% TOE OF DAM 755' POND RISER STRUCTURE EMERGENCY SPILLWAY: 758.5' DETENTION POND - POND 28B SCALE: 1"=30' (1) ANTI-SEEP COLLAR 4.25' x 4.25' CONCRETE MIN 4" THICK 3' CIRCULAR RISER (SEE DETAILS) 40' - 15" HDPE @ 5%INV=753' CONTRACTOR SHALL INSTALL 12' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 4' WIDE TO 14' WIDE. 18' EMERGENCY SPILLWAY- 758.5 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP 3:1 SIDE SLOPES 3:1 SIDE SLOPES DETENTION POND RISER STRUCTURE - POND 28B NOT TO SCALE 100 YEAR STORM (758.60') (1) 15" HOLE (754.5') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (756.57') DETENTION POND RISER STRUCTURE - POND 28A NOT TO SCALE 100 YEAR STORM (757.24') (1) 15" HOLE (755') 10 YEAR STORM (756.21') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD37758 759 760 761 762 763 764 764 763 762 761 760 759 758 764764762760758764 764 762 764 762 760 758 LDLDLDLDLDLD763 764 765 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5BB STORMWATER DETAILSPOND 28C & 28DCONTRACTOR SHALL INSTALL 14' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 6' WIDE TO 16' WIDE. 3' CIRCULAR RISER (SEE DETAILS) SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER INV=757' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION 40' - 24" HDPE @ 2.5% (1) ANTI-SEEP COLLAR 5.25' x 5.25' CONCRETE MIN 4" THICK 3:1 SIDE SLOPES DAM ELEV: 764' SLOPE 3:1 POND BOTTOM- 758' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 28C NTS RISER SPILLWAY: 761' INV OUT 757' 40' - 24" @ 2.5% TOE OF DAM 758' POND RISER STRUCTURE EMERGENCY SPILLWAY: 762' DETENTION POND - POND 28C SCALE: 1"=30' 8' EMERGENCY SPILLWAY- 762 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP 3:1 SIDE SLOPES DETENTION POND - POND 28D CONVERSION SCALE: 1"=30' DETENTION POND RISER STRUCTURE - POND 28C NOT TO SCALE 100 YEAR STORM (762.35') (1) 24" HOLE (758') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (760.39') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. SEDIMENT TRAP CONVERSION: CONTRACTOR SHALL FILL BOTTOM OF BASIN TO DRAIN USING MATERIAL USED IN DAM CONSTRUCTION. GRADING SHOWN IS APPROXIMATE ONLY. CONTRACTOR TO USE AVAILABLE DAM MATERIAL FOR FILLING. NO IMPORT IS NEEDED FOR CONVERSION. INV 38 760.50 761 762 763 764 765 766 767 768 769 770 771 771 770 769 768 767 766 765 764 763 762.50 771771763 765 767 771 770 769 768 767 766 765 764 763 762.50 762.50765767770771BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5CC STORMWATER DETAILSPOND 28ECONTRACTOR SHALL INSTALL 29' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 16' WIDE TO 31' WIDE. (2) 5' CIRCULAR RISERS (SEE DETAILS) SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER INV=761.9' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION (2) 60' - 30" HDPE @ 1% (1) ANTI-SEEP COLLAR 7.25' x 7.25' PER PIPE CONCRETE MIN 4" THICK 3:1 SIDE SLOPES DAM ELEV: 771' SLOPE 3:1 POND BOTTOM- 762.5' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 28E NTS RISER SPILLWAY: 768' INV OUT 761.9' (2) 60' - 30" @ 1% TOE OF DAM 763' POND RISER STRUCTURE (TYP. OF 2) EMERGENCY SPILLWAY: 769' DETENTION POND - POND 28E SCALE: 1"=30' 24' EMERGENCY SPILLWAY- 769 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP 3:1 SIDE SLOPES 3:1 SIDE SLOPES DETENTION POND RISER STRUCTURE - POND 28E NOT TO SCALE 100 YEAR STORM (769.09') (1) 30" HOLE PER RISER (762.5') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (765.54') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. LD LD 760.50761762763764765766767768769770771771770769768767766765764763762.50763765767762. 5 0 765 767 760 761 762 763 764 765 766 767 767 766 765 764 763 762 761 760.50 774 772 770 768 765 763 760.50 767 765 762 760.50 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5DD STORMWATER DETAILSPOND 28FCONTRACTOR SHALL INSTALL 18' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 12' WIDE TO 26' WIDE. (2) 4' CIRCULAR RISERS (SEE DETAILS) SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER INV=760' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION (2) 50' - 24" HDPE @ 1% (1) ANTI-SEEP COLLAR 5.25' x 5.25' PER PIPE CONCRETE MIN 4" THICK 3:1 SIDE SLOPES DAM ELEV: 767' SLOPE 3:1 POND BOTTOM- 760.5' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 28F NTS RISER SPILLWAY: 764' INV OUT 760' (2) 50' - 24" @ 1% TOE OF DAM 761' POND RISER STRUCTURE (TYP. OF 2) EMERGENCY SPILLWAY: 765' DETENTION POND - POND 28F SCALE: 1"=30' 16' EMERGENCY SPILLWAY- 765 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP 3:1 SIDE SLOPES 3:1 SIDE SLOPES DETENTION POND RISER STRUCTURE - POND 28F NOT TO SCALE 100 YEAR STORM (764.54') (1) 24" HOLE PER RISER (760.5') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (762.19') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. LDLDLDLDLDLDL D LD LD LD LD LD LD LD LD LD LD LD LD LD LD 752 753 754 755 756 757 758 758 757 756 755 754 753 753 754 755 756 757 758 7 5 3 7 5 4 7 5 5 7 5 6 7 5 7 7 5 8 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5EE STORMWATER DETAILSPOND 28GCONTRACTOR SHALL INSTALL 16' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 6' WIDE TO 18' WIDE. 3' CIRCULAR RISER (SEE DETAILS) SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER INV=751' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION 40' - 24" HDPE @ 5% (1) ANTI-SEEP COLLAR 5' x 5' CONCRETE MIN 4" THICK 3:1 SIDE SLOPES DAM ELEV: 758' SLOPE 3:1 POND BOTTOM- 753' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 28G NTS RISER SPILLWAY: 755.5' INV OUT 751' 40' - 24" @ 5% TOE OF DAM 752' POND RISER STRUCTURE EMERGENCY SPILLWAY: 756.5' DETENTION POND - POND 28G SCALE: 1"=30' 20' EMERGENCY SPILLWAY- 756.5 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP 3:1 SIDE SLOPES DETENTION POND RISER STRUCTURE - POND 28G NOT TO SCALE 100 YEAR STORM (755.69') (1) 24" HOLE (753') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (754.24') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. OHP OHP OHP OHP OHP OHP OHP LD LD LD LD LD LD LD LD LD LD LD 770 771 772 773 774 775 776 776 776 775 774 773 772 771 771 772 773 774 775 776 OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP LD LD LD LD LD LD LD LD LD LD LD LD LD LD 760 761 762 763 764 765 766 766 765 764 763 762 761 766 766 766 767 761 762 763 764 765 766 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5FF STORMWATER DETAILSPOND 29A & 30ACONTRACTOR SHALL INSTALL 12' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 4' WIDE TO 14' WIDE. 3' CIRCULAR RISER (SEE DETAILS) SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER INV=770' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION 40' - 15" HDPE @ 2.5% (1) ANTI-SEEP COLLAR 4' x 4' CONCRETE MIN 4" THICK 3:1 SIDE SLOPES DAM ELEV: 775' SLOPE 3:1 POND BOTTOM- 771' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 29A NTS RISER SPILLWAY: 773.5' INV OUT 770' 40' - 15" @ 2.5% TOE OF DAM 771' POND RISER STRUCTURE EMERGENCY SPILLWAY: 774.5' DETENTION POND - POND 29A SCALE: 1"=30' 8' EMERGENCY SPILLWAY- 774.5 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP 3:1 SIDE SLOPES DAM ELEV: 766' SLOPE 3:1 POND BOTTOM- 761' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 30A NTS RISER SPILLWAY: 763.5' INV OUT 760' 40' - 18" @ 2.5% TOE OF DAM 761' POND RISER STRUCTURE EMERGENCY SPILLWAY: 764.5' DETENTION POND - POND 30A SCALE: 1"=30' CONTRACTOR SHALL INSTALL 16' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 5' WIDE TO 18' WIDE. 3' CIRCULAR RISER (SEE DETAILS) SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER INV=760' 40' - 18" HDPE @ 2.5% (1) ANTI-SEEP COLLAR 4' x 4' CONCRETE MIN 4" THICK 3:1 SIDE SLOPES 14' EMERGENCY SPILLWAY- 764.5 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP 3:1 SIDE SLOPES DETENTION POND RISER STRUCTURE - POND 30A NOT TO SCALE 100 YEAR STORM (763.86') (1) 18" HOLE (761') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (762.31') DETENTION POND RISER STRUCTURE - POND 29A NOT TO SCALE 100 YEAR STORM (773.88') (1) 15" HOLE (771') 10 YEAR STORM (772.37') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHPLDLDLDLDLDLDL D LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD 74 6 747 748 752 751 750 749 748 747 746 757 756 755 754 753 751750749 748 747 746 752750748746748 753757757755753751755754753 752 757 756 751 752 752 749 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5GG STORMWATER DETAILSPOND 30B LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION DAM ELEV: 752' SLOPE 3:1 POND BOTTOM- 746' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 30B NTS RISER SPILLWAY: 748.5' INV OUT 745' 50' - 24" @ 2% TOE OF DAM 746' POND RISER STRUCTURE EMERGENCY SPILLWAY: 749.5' DETENTION POND - POND 30B SCALE: 1"=30' CONTRACTOR SHALL INSTALL 14' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 6' WIDE TO 16' WIDE. 3' CIRCULAR RISER (SEE DETAILS) SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER INV=745' 50' - 24" HDPE @ 2% (1) ANTI-SEEP COLLAR 5.25' x 5.25' CONCRETE MIN 4" THICK 3:1 SIDE SLOPES 110' - 30" HDPE @ 4.55% 3:1 SIDE SLOPES INV=751' INV=746' CONTRACTOR SHALL INSTALL 18' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 8' WIDE TO 20.5' WIDE. 3:1 SIDE SLOPES 3:1 SIDE SLOPES 8' EMERGENCY SPILLWAY- 749.5 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP DETENTION POND RISER STRUCTURE - POND 30B NOT TO SCALE 100 YEAR STORM (749.06') (1) 24" HOLE (746') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (747.45') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. LD LD LD LD LD LD LDLD772 773 774 LDLD LD LD LD LD LDLD770 771 772 773 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D D-4HH SEDIMENT BASIN DETAILSTRAP 31A & 32A LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 DETENTION POND - POND 31A CONVERSION SCALE: 1"=30' DETENTION POND - POND 32A CONVERSION SCALE: 1"=30' SEDIMENT TRAP CONVERSION: CONTRACTOR SHALL FILL BOTTOM OF BASIN TO DRAIN USING MATERIAL USED IN DAM CONSTRUCTION. GRADING SHOWN IS APPROXIMATE ONLY. CONTRACTOR TO USE AVAILABLE DAM MATERIAL FOR FILLING. NO IMPORT IS NEEDED FOR CONVERSION. SEDIMENT TRAP CONVERSION: CONTRACTOR SHALL FILL BOTTOM OF BASIN TO DRAIN USING MATERIAL USED IN DAM CONSTRUCTION. GRADING SHOWN IS APPROXIMATE ONLY. CONTRACTOR TO USE AVAILABLE DAM MATERIAL FOR FILLING. NO IMPORT IS NEEDED FOR CONVERSION. LD LD LD LD LD LD LD LDLD762 763 764 765 766 767 767 766 765 764 763 763 765 767 775 LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD 768 769 770 771 772 775 772 771 770769.50 771 775 772 771 770 769.50 772 773 774 775 775 773774775 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5II STORMWATER DETAILSPOND 33A & 34A LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION 3:1 SIDE SLOPES 3:1 SIDE SLOPES DETENTION POND - POND 33A CONVERSION SCALE: 1"=30' SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER DAM ELEV: 775' SLOPE 3:1 POND BOTTOM- 769.5' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 34A NTS RISER SPILLWAY: 772' INV OUT 768' (2) 40' - 24" @ 3.75% TOE OF DAM 769' POND RISER STRUCTURE (TYP. OF 2) EMERGENCY SPILLWAY: 773' DETENTION POND - POND 34A SCALE: 1"=30' CONTRACTOR SHALL INSTALL 16' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 12' WIDE TO 24' WIDE. (2) 3' CIRCULAR RISERS (SEE DETAILS) SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER INV=768'(2) 40' - 24" HDPE @ 3.75% (1) ANTI-SEEP COLLAR 4.75' x 4.75' PER PIPE CONCRETE MIN 4" THICK 3:1 SIDE SLOPES 3:1 SIDE SLOPES 3:1 SIDE SLOPES 12' EMERGENCY SPILLWAY- 773 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP DETENTION POND RISER STRUCTURE - POND 34A NOT TO SCALE 100 YEAR STORM (771.29') (1) 24" HOLE PER RISER (769.5') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (770.2') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. SEDIMENT TRAP CONVERSION: CONTRACTOR SHALL FILL BOTTOM OF BASIN TO DRAIN USING MATERIAL USED IN DAM CONSTRUCTION. GRADING SHOWN IS APPROXIMATE ONLY. CONTRACTOR TO USE AVAILABLE DAM MATERIAL FOR FILLING. NO IMPORT IS NEEDED FOR CONVERSION. CONTRACTOR TO EXCAVATE POND DAM TO PROMOTE POSITIVE DRAINAGE. REUSE EXISTING STONE FROM SPILLWAY FOR OUTLET PROTECTION LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLD LD LD LD LD LD LD LD LDLDLDLDLDLDLD791792793794795796 796795 794 793 792 791 796796795793791796 795 793 791 791793795797803 802 802 801 804 803 802801800799798797 803 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5JJ STORMWATER DETAILSPOND 37A LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION DAM ELEV: 796' SLOPE 3:1 POND BOTTOM- 791' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 37A NTS RISER SPILLWAY: 793.5' INV OUT 790' 40' - 24" @ 2.5% TOE OF DAM 791' POND RISER STRUCTURE EMERGENCY SPILLWAY: 794.5' DETENTION POND - POND 37A SCALE: 1"=30' CONTRACTOR SHALL INSTALL 16' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 6' WIDE TO 18' WIDE. 3' CIRCULAR RISER (SEE DETAILS) SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER INV=790' 40' - 24" HDPE @ 2.5% (1) ANTI-SEEP COLLAR 4.75' x 4.75' CONCRETE MIN 4" THICK 3:1 SIDE SLOPES 3:1 SIDE SLOPES 24' EMERGENCY SPILLWAY- 794.5 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP DETENTION POND RISER STRUCTURE - POND 37A NOT TO SCALE 100 YEAR STORM (792.87') (1) 24" HOLE (791') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. 10 YEAR STORM (791.68') MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD801802 803 804 805 806 806 805 804 803 802 801 801802803804805806 806 806 807806 806804 800BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5KK STORMWATER DETAILSPOND 39A LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION DAM ELEV: 806' SLOPE 3:1 POND BOTTOM- 801' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 39A NTS RISER SPILLWAY: 803.5' INV OUT 800' 40' - 18" @ 2.5% TOE OF DAM 802' POND RISER STRUCTURE EMERGENCY SPILLWAY: 804.5' DETENTION POND - POND 39A SCALE: 1"=30' CONTRACTOR SHALL INSTALL 16' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 6' WIDE TO 18' WIDE. 3' CIRCULAR RISER (SEE DETAILS) SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER INV=800' 40' - 18" HDPE @ 2.5% (1) ANTI-SEEP COLLAR 4.5' x 4.5' CONCRETE MIN 4" THICK 3:1 SIDE SLOPES 3:1 SIDE SLOPES 16' EMERGENCY SPILLWAY- 804.5 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP DETENTION POND RISER STRUCTURE - POND 39A NOT TO SCALE SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. 100 YEAR STORM (802.99') 10 YEAR STORM (801.68') (1) 18" HOLE (801') 3:1 SIDE SLOPES LDLDLDLDLDLDLDLDLDLDLDLDLD822820818816815814814 815 816 817 818 819 819 817 815 814 822820818816814LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD830 831 832 833 834 835 836 837 838 839 840 841 841 840 839 838 837 848 847 846 845 844 843 842 841 840 839 838 837 8378378 4 1 8 4 1 842BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 22602Know what's below. before you dig.Call R 21-0281_D-BMP D-5LL STORMWATER BASINPOND 2A & 2-1AKnow what's below. before you dig.Call R NOTE:POND MUST BE STABILIZED WITHIN 14 DAYS OF CONSTRUCTION DAM ELEV: 819' SLOPE 3:1 POND BOTTOM- 814' * FOR DEPTH AND ELEVATION PURPOSES ONLY. THIS IS NOT AN ACCURATE DEPICTION OF THE POND CROSS-SECTION SLOPE STABILIZATION NOTE: INTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF MATTED SEED OR SOD. DETENTION POND DETAIL - POND 2A NTS RISER SPILLWAY: 816.5' INV OUT 813' 40' - 24" @ 2.5% TOE OF DAM 814' POND RISER STRUCTURE EMERGENCY SPILLWAY: 817.5' DETENTION POND - POND 2A SCALE: 1"=30' CONTRACTOR SHALL INSTALL 14' LONG, 18" DEEP VDOT CLASS 1 RIP RAP TRANSITIONING FROM 6' WIDE TO 16' WIDE. 3' CIRCULAR RISER (SEE DETAILS) SLOPES SHALL BE BLANKET MATTED WITH NAG S150 OR GREATER INV=813' 40' - 24" HDPE @ 2.5% (1) ANTI-SEEP COLLAR 5.75' x 5.75' CONCRETE MIN 4" THICK 3:1 SIDE SLOPES 3:1 SIDE SLOPES 20' EMERGENCY SPILLWAY- 817.5 TO BE ARMORED WITH VDOT CLASS 1 RIP RAP 3:1 SIDE SLOPES 3:1 SIDE SLOPES DETENTION POND - POND 2-1A CONVERSION SCALE: 1"=30' LEGEND: EXIST / PROPOSED EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR DROP INLET CURB INLET FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE JUNCTION BOX PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE 100 98 DETENTION POND RISER STRUCTURE - POND 2A NOT TO SCALE (1) 24" HOLE (814') SEDIMENT BASIN TO DETENTION POND CONSTRUCTION SEQUENCE: AT THE COMPLETION OF CONSTRUCTION (WHEN THE ENTIRE SITE IS STABILIZED) THE SEDIMENT BASIN SHALL BE CONVERTED INTO A STORMWATER DETENTION POND. THE FOLLOWING STEPS SHALL BE FOLLOWED: 1.DEWATER THE BASIN THROUGH SEDIMENT BAG. 2.BAG SHALL DISCHARGE INTO A STABLE AGGREGATE DISSIPATOR PAD OR A DENSELY VEGETATED AREA. 3.REMOVE DEPOSITED SEDIMENT AND PROPERLY DISPOSE OFF-SITE. 4.ADJUST GRADES AS NECESSARY TO MATCH PLANS. THIS INCLUDES CHANGES TO ROCK OUTLET STRUCTURE TO MATCH DETENTION POND PLANS IF CHANGED. 5.AS-BUILT CONDITIONS SHOULD BE VERIFIED PRIOR TO PLANTING TO ENSURE SIZE, SLOPES, BOTTOM ELEVATION, ETC. ARE ADEQUATE. 6.INSTALL 3-4" OF TOPSOIL TO INTERIOR SLOPES, FERTLIZE, LIME, AND EITHER SOD OR SEED AND MAT. 7.REMOVE ANTI-VORTEX DEVICE(S) AND GROUT DEWATERING ORIFICE. INSTALL PERMANENT ORIFICE(S) AND TRASH RACK. ENSURE PERMANENT ORIFICE AND BOTTOM OF POND ELEVATIONS MATCH PLANS. 8.WATER GRASS AS NECESSARY TO HELP ESTABLISHMENT. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING HEALTHY STAND OF GRASS. MAINTENANCE: DURING AND AFTER CONSTRUCTION THE STORMWATER DETENTION BASIN MUST BE PERIODICALLY CHECKED FOR PROPER FUNCTION. THE BASIN SHALL ALSO BE INSPECTED AFTER RAIN EVENTS. PROPER FUNCTION WILL BE EVIDENT BY A DRY POND CONDITION. PERIODS OF EXTENDED PONDING INDICATE A BLOCKED DISCHARGE ORIFICE. ROUTINE INSPECTION TO BE DONE BY WALKING DOWN AND VISUALLY INSPECTING. IF ORIFICE FOUND TO BE CLOGGED BY TRASH OR SEDIMENT IT SHALL BE REMOVED AND PROPERLY DISPOSED OF. IN THE EVENT THERE ARE SLOPE FAILURES OR LARGE MAINTENANCE ISSUES A TRACKED EXCAVATOR SHALL BE USED TO ACCESS THE POND. 100 YEAR STORM (815.86') 10 YEAR STORM (814.66') SEDIMENT TRAP CONVERSION: CONTRACTOR SHALL FILL BOTTOM OF BASIN TO DRAIN USING MATERIAL USED IN DAM CONSTRUCTION. GRADING SHOWN IS APPROXIMATE ONLY. CONTRACTOR TO USE AVAILABLE DAM MATERIAL FOR FILLING. NO IMPORT IS NEEDED FOR CONVERSION. CONTRACTOR TO EXCAVATE POND DAM TO PROMOTE POSITIVE DRAINAGE. REUSE EXISTING STONE FROM SPILLWAY FOR OUTLET PROTECTION BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_D-BMP D-6 SITE DETAILSEXISTING GRADE 24'-26' 20'-22'2'2' TYPICAL ACCESS ROAD CROSS SECTION NTS GAME FENCE DETAIL GATE DETAIL 3'3'3'3'19.875'7'-2 5 8" 3' 3' EXISTING/PROPOSED GRADE (3:1 MAX) EXISTING/PROPOSED GRADE (3:1 MAX) TOP OF SKID (SEE STRUCTURAL DRAWINGS) PILE FOUNDATIONS (SEE STRUCTURAL DRAWINGS) GENERAL FILL 6" REVEAL @ TOP OF PILE PER STRUCTURAL DRAWI NGS 6" OF 3 4" CLEAR, CLEAN, CRUSHED STONE 2% (TYP) 3:1 MA X 2% (TYP) 3:1 M A X INVERTER SKID PLAN VIEW (MORE DETAILS ON STRUCTURAL/ELECTRICAL PLAN) NTS INVERTER SKID CROSS SECTION NTS INVERTER SKID CONTAINS SELF-CONTAIN SECONDARY CONTAINMENT TANK EXISTING GRADE 24'-26' 20'-22'2'2' TYPICAL ACCESS ROAD CROSS SECTION (CONCRETE) NTS NOTES: 1.CONTROL JOINTS TO BE PROVIDED AT INTERVALS EQUAL TO THE WIDTH OF THE CONCRETE BY SAWING, SCORING, "LEAVE-IN" INSERTS, OR CUTTER PLATES AND SHALL EXTEND INTO THE CONCRETE 1/4 OF THE DEPTH. 2.AS SOON AS CONCRETE WILL NOT SLUMP, FACE FORMS ARE TO BE REMOVED, IRREGULARITIES REMOVED, A LIGHT BROOM FINISH GIVEN, AND A LIQUID MEMBRANE SEAL OR OTHER APPROVED CURING MEDIUM APPLIED. 3.SIDEWALKS ACROSS ENTRANCES SHALL HAVE A DEPTH OF 7" WITH A MAXIMUM SLOPE OF 1:12. 4.THE CONTRACTOR SHALL PREVENT THE TEMPERATURE AT THE SURFACE OF THE CONCRETE FROM FALLING BELOW 40°F DURING THE FIRST 72 HOURS IMMEDIATELY FOLLOWING CONCRETE PLACEMENT. PROTECTIVE MATERIAL SHALL BE LEFT IN PLACE FOR AN ADDITIONAL 48 HOURS IF FREEZING AIR TEMPERATURES ARE EXPECTED TO CONTINUE. SAWCUT CONTROL JOINT 1/4" WIDE x 1/4 SLAB DEPTH MIN. 4" VDOT 57 STONE 8" CONCRETE SLAB 6x6-W1.4xW1.4 WWF 8"4"CONTROL JOINT DETAIL SCALE: 3/4"=1'-0" COMPACTED SUBGRADE 810 811 812 813 50'25'25' EXISTING PAVEMENT PROPOSED GRAVEL ACCESS RD (CROSS SECTION THIS SHEET) 8" OF VDOT CLASS A4 W/ WELDED WIRE REINFORCEMENT EXISTING SOIL TO BE COMPACTED TO 95% OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM D698) WOVEN GEOTEXTILE FABRIC (US 200 OR EQUIVALENT) MINIMUM 4" OF VDOT 57 STONE CONCRETE DRIVEWAY FLOW SECTION ALONG CENTERLNIE (SHOWN ON C-4.16) NTS MATCH EXISTING 810.4 811.4 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_D-BMP D-7 SITE/UTILITY DETAILSFREDERICK WATER NOTES: 1.CONTRACTOR SHALL CONTACT FREDERICK WATER TO COORDINATE ANY WORK IN THE EXISTING WATER EASEMENT. CONTRACTOR SHALL ENSURE THAT FREDERICK WATER MAINTAINS ACCESS TO THEIR EASEMENT. . SUBMITTALS: ·TESTING PERSONNEL ON SITE ARE RESPONSIBLE FOR VERIFYING THAT PROPOSED MATERIALS MEET THE STANDARDS CALLED OUT ON PLANS, INCLUDING ANY TESTING REQUIREMENTS. ·ANY SUBSTITUTIONS TO THE MATERIALS CALLED OUT ON PLANS SHALL BE SUBMITTED TO THE ENGINEER OF RECORD (EOR) TO CONFIRM AS CONFORMING TO THE PLANS. BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_D-BMP D-8 LANDSCAPING DETAILSGENERAL LANDSCAPING NOTES: 1.LANDSCAPE CONTRACTOR SHALL HAVE ALL UNDERGROUND UTILITIES AND PROPOSED SITE LIGHTING POLE LOCATIONS LOCATED PRIOR TO INSTALLING PLANT MATERIAL. 2.CONTRACTOR SHALL COMPLY WITH SIZING AND GRADING STANDARDS OF THE LATEST EDITION OF THE "AMERICAN STANDARD FOR NURSERY STOCK" BY THE AMERICAN ASSOCIATION OF NURSERYMEN (AAN). 3.CONTRACTOR SHALL NOT PLANT NEW PLANT MATERIAL IN CRITICAL ROOT ZONES OF EXISTING TREES TO BE SAVED AND PROTECTED ON SITE. 4.ANY DISTURBED AREAS NOT SCHEDULED FOR HARDSCAPE, PLANTING, SOD OR MULCH SHALL BE SEEDED LAWN. 5.CONTRACTOR SHALL AMEND ALL PROPOSED PLANT BEDS WITH ORGANIC SOIL AMENDMENT (COMPOST). ROTOTILL BEDS TO A DEPTH OF 8", ADD 2" OF COMPOST AND ROTOTILL AGAIN. REMOVE ALL EXIST. WEEDS, GRASS AND ROOTS. 6.CONTRACTOR SHALL RAKE SMOOTH AND APPLY 1" TO 2" TOPSOIL TO ALL LAWN AREAS RECEIVING SEED. REMOVE ALL EXIST. WEEDS, GRASS AND ROOTS. 7.ALL PLANT AND BED LINE LOCATIONS SHALL BE STAKED IN THE FIELD AND APPROVED BY THE OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. 8.ALL PLANTINGS SHALL BE INSTALLED WITH THE SPECIFIED LAYER OF MULCH. REFERENCE DETAILS FOR DEPTH AND TYPE OF MULCH. ALL TREES AND SHRUBS SHALL BE PLANTED IN MULCH BEDS. 9.FINISHED GRADE IN LANDSCAPE ISLANDS THAT ARE TO RECEIVE MULCH SHALL BE SET SO THAT IT IS ONE INCH LOWER THAN THE TOP OF SURROUNDING CURBS. MULCH WITH 3" OF TRIPLE SHREDDED HARDWOOD MULCH FROM A REPUTABLE LOCAL SOURCE. 10.CONTRACTOR SHALL PROVIDE WATER PERMEABLE WEED MAT FOR ALL PLANTING BEDS. 11.ALL LANDSCAPING SHALL CONFORM TO THE ZONING ORDINANCE §165-203.02. 12.ANY PROPOSED SHRUBS SHALL BE 18" TALL. COMMON NAMESYM./KEY BOTANICAL NAME MATURE HGTCALIPERINITIAL HEIGHT SPACINGROOT SPECIFICATION PLANTING SELECTION LIST B&B AS SHOWNLILagerstroemia indica (SMALL DECIDS)Crape Myrtle American ElderSambucus canadensisAE AS SHOWN18" 6'-15' 5'-12' DECIDUOUS SHRUBS B&B AS SHOWNAcer Palmatum (SMALL DECIDUOUS)Japenese Maple 20'-35' B&B AS SHOWNTsuga Caroliniana (EVERGREEN)Carolina Hemlock 30'-70' JM CH B&B AS SHOWNPinus Virginiana (EVERGREEN)Virginia Pine 30'-70'VP B&B AS SHOWNMagnolia Virginiana (EVERGREEN)Sweetbay Magnolia 10'-60'SM Virginia SweetspireItea Virginica AS SHOWN18"3'-8' Wintergreen BarberryBerberis Julianae (EVERGREEN)AS SHOWN18"6' BoxwoodBuxus Varieties (EVERGREEN)AS SHOWN18"VARIES VS WB BW Hybrid AzaleaAzalea Hybrids (EVERGREEN)AS SHOWN18"6' Vernal Witch HazelHamamelis Vernalis AS SHOWN18"6'-10'HV HA B&B AS SHOWNEROQuercus rubra Northern Red Oak 50'-70' EVERGREEN SHRUBS EVERGREEN TREES SMALL DECIDUOUS TREES LARGE DECIDUOUS TREES B&B AS SHOWNWAFraxinus Americana White Ash 60'-100' B&B AS SHOWNAmerican Beech AS SHOWN 60'-80'Fagus GrandifoliaFG AS SHOWN AS SHOWN AS SHOWN AS SHOWN AS SHOWN AS SHOWN AS SHOWN AS SHOWN AS SHOWN AS SHOWN AS SHOWN AS SHOWN AS SHOWN AS SHOWN AS SHOWN COMMON NAMESYM./KEY BOTANICAL NAME MATURE HGTCALIPERINITIAL HEIGHT SPACINGROOT SPECIFICATION PLANTING SCHEDULE NOTES: CONTRACTOR SHALL UTILIZE EXISTING VEGETATION WHEREVER POSSIBLE ON THIS PROJECT. IN AREAS WHERE PLANTINGS ARE REQUIRED THE CONTRACTOR SHALL SELECT PLANTS FROM THE LIST BELOW OR SUBMIT AN EQUAL PLANT THAT IS APPROVED BY THE OWNER, ENGINEER, & FREDERICK COUNTY PLANNING. Old Gold JuniperJuniperus x media (EVERGREEN)AS SHOWN18"VARIESGJ LANDSCAPE BUFFER A1 LANDSCAPE BUFFER B1 LANDSCAPE BUFFER C1 LANDSCAPE BUFFER D1 LANDSCAPE BUFFER E1 LANDSCAPE BUFFER F1 LANDSCAPE BUFFER A2 LANDSCAPE BUFFER B2 LANDSCAPE BUFFER C2 LANDSCAPE BUFFERS FROM CUP #05-20 LANDSCAPE BUFFERS FROM CUP #11-21 PLANTING SCHEDULE NOTE: LANDSCAPING MATERIALS SHALL BE SELECTED FOLLOWING PLANTING SELECTION LIST (THIS SHEET) OR APPROVED ALTERNATIVE READILY AVAILABLE IN VICINITY OF PROJECT. CONTRACTOR SHALL CONTACT OWNER, ENGINEER, AND FREDERICK COUNTY PLANNING WITH ANY ALTERNATIVES PRESENT. THIS SCHEDULE IS AN ESTIMATE OF THE QUANTITY OF PROPOSED TREES FOR THE VARIOUS BUFFERS SHOWN IN THIS PLAN SHEET. MORE TREES MAY BE REQUIRED AT THE DIRECTION OF FREDERICK COUNTY PLANNING IF SCREENING IS NOT MET. LANDSCAPING BUFFER SPACING DESCRIPTION QTY DECIDUOUS QTY EVERGREEN DECIDUOUS PLANTED CALIPER EVERGREEN PLANTED HEIGHT A1 BUFFER B1 BUFFER C1 BUFFER D1 BUFFER E1 BUFFER F1 BUFFER A2 BUFFER B2 BUFFER C2 BUFFER TOTAL 84 60 25 1.25" 1.25" 1.25" 84 848 60 188 79 143 25 243 200 6' 6' 6' 6' 6' 6' 6' 6' 6' 15' ON CENTER 15' ON CENTER 15' ON CENTER 15' ON CENTER 15' ON CENTER 15' ON CENTER 15' ON CENTER 15' ON CENTER 15' ON CENTER SEE ABOVE DETAILS SEE ABOVE DETAILS SEE ABOVE DETAILS SEE ABOVE DETAILS SEE ABOVE DETAILS SEE ABOVE DETAILS SEE ABOVE DETAILS SEE ABOVE DETAILS SEE ABOVE DETAILS 169 1870 OHPOHPOHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OH P OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP LDLDLDLDLDL D L D LD0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 755 760 765 770 775 755 760 765 770 775 0+00769.7769.660+50768.6768.591+00767.9767.871+50767.7767.672+00767.4767.362+50767.0766.983+00766.1766.143+50764.8764.804+00763.2763.214+50762.6762.655+00762.0761.985+50761.8761.796+00761.3761.306+50760.8760.827+00760.1760.117+50760.0760.008+00759.8759.838+50759.1759.089+00759.0759.039+50759.0759.0410+00758.9758.86750 755 760 750 755 760 0+00757.0757.000+50756.4756.441+00755.4755.371+50754.1754.102+00753.6753.612+50753.8753.783+00753.9753.893+50753.9753.924+00753.0753.044+50752.9752.915+00753.0753.035+50753.6753.576+00753.9753.916+50754.1754.117+00754.8754.767+50754.9754.938+00755.0755.018+50755.3755.269+00756.0756.019+50756.0756.0310+00757.0757.0110+38.38757.0757.02LD LD LDLD LD LD LDLDLDLD LD LD LD LD LD LD LD LD LD 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 10+38 BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_D-BMP D-9 VDOT ENTRANCE DETAILSMARLBORO RD STA 0+00 - 10+00 (STRODE MCLOED LN EXISTING ENTRANCE- CONTRACTOR TO IMPROVE IF NECESSARY)℄ DRIVEWAY(EXISTING STRODE MCLOED LN)STA. - 5+00END SDLSTA. - 0+00HORIZONTAL SCALE: 1"=50' VERTICAL SCALE: 1"=5' LINE OF SIGHT PROPOSED/EXISTING GRADE ALONG ℄ SIGHT LINE END SDRSTA. - 10+003.5' HEIGHT OF EYE 3.5' HEIGHT OF OBJECT 3.5' HEIGHT OF OBJECT MARLBORO RD 45 MPH SDR - 500' 45 MPH SDL - 500' SPRINGDALE RD STA 0+00 - 10+38.38 (SOUTHEAST ENTRANCE TO PHASE 1 ACROSS FROM BASEBALL FIELDS)℄ DRIVEWAYSTA. - 4+28.38END SDLSTA. - 0+00HORIZONTAL SCALE: 1"=50' VERTICAL SCALE: 1"=5' LINE OF SIGHT PROPOSED/EXISTING GRADE ALONG ℄ SIGHT LINE END SDRSTA. - 10+38.383.5' HEIGHT OF EYE 3.5' HEIGHT OF OBJECT 3.5' HEIGHT OF OBJECT SPRINGDALE RD 55 MPH SDR - 610'STOP CONDITION SDL - 428.38' R4 5 . 0 0 ' R45.0 0' 22.00' R50'R50' 22.00' ALL BRUSH AND VEGETATION WITHIN SIGHT DISTANCE LINES SHALL BE REMOVED FOR LIFE OR PROJECT ALL BRUSH AND VEGETATION WITHIN SIGHT DISTANCE LINES SHALL BE REMOVED FOR LIFE OR PROJECT 6000 805.42 CPP N A I L0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+0012+200+00 1+00 2+00 3+00 4+00 5+00 6+00 7+008+009+0010+0011+0012+0012+20 806807808809810811812812.50812.508128118108098088078068 1 8 8 1 5 8 1 3 8 1 0 8 0 8 8 0 6 823 820 817 815 81 2 81 0 80 8 80 6 80 7 81 0 81 2 81 2 . 5 0 81 2 . 5 0 8 1 3 8 1 4 81 5 81 7 81 7815 812 812815817815 815 813 810 809 808 807 810 80 7808 805 810 815 820 825 830 805 810 815 820 825 830 0+00824.0824.040+50823.0823.031+00822.0822.001+50821.0821.002+00820.0819.992+50819.0818.983+00818.0817.953+50817.0816.984+00816.0815.984+50814.9814.955+00814.0813.955+50813.0812.996+00812.0811.976+50811.0811.007+00810.0809.987+50809.0808.998+00808.3808.298+50808.0807.999+00807.0807.009+50807.0807.0010+00807.1807.0810+50807.0807.0211+00807.0807.0211+50809.9809.9512+00813.7813.6512+20814.5814.53805 810 815 820 825 830 805 810 815 820 825 830 0+00813.4813.440+50811.2811.181+00808.0807.971+50807.0807.002+00807.4807.372+50807.0807.003+00807.2807.233+50808.0807.994+00809.3809.354+50810.4810.365+00811.0811.035+50811.4811.426+00811.2811.256+50812.0812.007+00813.3813.277+50814.5814.518+00815.9815.878+50817.0817.019+00818.1818.059+50819.1819.0610+00820.0820.0310+50821.1821.0611+00822.1822.0611+50823.0823.0412+00824.0824.0312+20824.1824.10BYDATEREVISIONS132456PROJECT NO. SHEET NO.DRAWING ALTERATIONIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OFLICENSED ARCHITECT, PROFESSIONALENGINEER, LANDSCAPE ARCHITECT, ORLAND SURVEYOR TO ALTER ANY ITEM ONTHIS DOCUMENT IN ANY WAY. ANY LICENSEEWHO ALTERS THIS DOCUMENT IS REQUIREDBY LAW TO AFFIX HIS OR HER SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISOR HER SIGNATURE AND SPECIFICDESCRIPTION OF THE ALTERATIONS.PROJECT ENGINEER/ARCHITECTPROJECT MANAGERDRAWN BY7DRAWING NAME:COPYRIGHT 2017SUMMIT DESIGN ANDENGINEERING SERVICESCMWH (MATT.HASTINGS@SUMMITDE.COM)MWH (MATT.HASTINGS@SUMMITDE.COM)21-0281.V01BARTONSVILLE SOLARSPRINGDALE ROADSITE DEVELOPMENT PLANSFIRST ISSUE DATEJSE (SETH.EPPERSON@SUMMITDE.COM)02-17-2022WINCHESTER, VIRGINIA 2260221-0281_D-BMP D-10 VDOT ENTRANCE DETAILSSPRINGDALE RD STA 0+00 - 12+20 (SOUTHERN ENTRANCE)℄ DRIVEWAYSTA. - 6+10END SDLSTA. - 0+00HORIZONTAL SCALE: 1"=50' VERTICAL SCALE: 1"=5' LINE OF SIGHT PROPOSED GRADE ALONG ℄ SIGHT LINE END SDRSTA. - 12+203.5' HEIGHT OF EYE 3.5' HEIGHT OF OBJECT 3.5' HEIGHT OF OBJECT SPRINGDALE RD 55 M P H SDR - 6 1 0 ' 55 MPH SDL - 610'℄ DRIVEWAYSTA. - 6+10END SDLSTA. - 0+00HORIZONTAL SCALE: 1"=50' VERTICAL SCALE: 1"=5' LINE OF SIGHT PROPOSED GRADE ALONG ℄ SIGHT LINE END SDRSTA. - 12+203.5' HEIGHT OF EYE 3.5' HEIGHT OF OBJECT 3.5' HEIGHT OF OBJECT EXISTING GRADE ALONG ℄ SIGHT LINE EXISTING GRADE ALONG ℄ SIGHT LINE SPRINGDALE RD STA 0+00 - 12+20 (NORTHERN ENTRANCE) ALL BRUSH AND VEGETATION WITHIN SIGHT DISTANCE LINES SHALL BE REMOVED FOR LIFE OR PROJECT