HomeMy WebLinkAbout47-22 Site PlanSITE
2022-08-18
U:\Accounts\EMBAP\EMBAP22001 - Emmanuel Baptist Church Minor Site Plan\DESIGN\_SHEETS\CS0000.dwg PLOTTED: 8/18/2022 12:41 PM, BY: Teri Hermen PLOTSTYLE: Pennoni NCS.stb PROJECT STATUS: ----CS0000 BYNO.DATEREVISIONSEMBAP22001
AS SHOWN
TLH
2022-06-30
MMA
SHEET
APPROVED BY
OF1 2
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPREPARED FOR:
OWNER/DEVELOPER
EMMANUEL BAPTIST CHURCH
2774 NORTHWESTERN PIKE
WINCHESTER, VA 22603
540-667-8924
EMMANUEL BAPTIST CHURCH,
STORAGE ADDITION
MINOR SITE PLAN
SP#47-22
WINCHESTER, VA 22603
ORIG SUBMISSION DATE: JULY 19TH, 2022
REVISED SUBMISSION DATE: AUGUST 18TH, 2022
LOCATION MAP
Scale: 1" = 1000'NORTHCALL 1-800-552-7001
CALL BEFORE YOU DIG
ALWAYS CALL 811 BEFORE YOU DIG IN VIRGINIA
SECTION 56-265.17 REQUIRES THREE WORKING DAYS
NOTICE TO UTILITIES BEFORE YOU EXCAVATE, DRILL OR
BLAST VIRGINIA UTILITY PROTECTION SERVICE, INC.
TICKET NUMBER(S):
PREPARED BY:PENNONI ASSOCIATES INC.
117 East Piccadilly Street
Winchester, VA 22601
T 540.667.2139
F 540.665.0493 APPROVED PERMIT DRAWINGS
2022-08-18 PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493LOCAL UTILITIES
RAPPAHANNOCK ELECTRIC CO-OP
137 KELLEY COURT
FRONT ROYAL, VIRGINIA 22630
(540) 662-2037
VERIZON
404 HILLANDALE LANE
WINCHESTER, VIRGINIA 22602
(540) 665-3156
COMCAST COMMUNICATIONS
195 RAINVILLE ROAD
WINCHESTER, VIRGINIA 22602
(540) 504-0942
WASHINGTON GAS
350 HILLANDALE LN.
WINCHESTER, VIRGINIA 22602
(540) 868-7913
FREDERICK WATER (WATER & SEWER)
315 TASKER ROAD
STEPHENS CITY, VIRGINIA 22655
(540) 868-1061
RESPONSIBLE LAND DISTURBER
THE RESPONSIBLE LAND DISTURBER IS THAT PARTY RESPONSIBLE FOR CARRYING
OUT THE LAND DISTURBING ACTIVITY AS SET FORTH IN THE PLANS.
NAME:_____________________________________________________
CERTIFICATION #:___________________________________________
DATE: _____________________________________________________
APPROVED BY FREDERICK COUNTY ZONING ADMINISTRATOR
________________________________________________________________________________
APPROVED BY DATE
SITE PLAN VALID FOR FIVE (5) YEARS FROM APPROVAL DATE
GENERAL CONSTRUCTION NOTES:
1. THE CONTRACTOR SHALL FURNISH ALL MATERIALS, LABOR AND EQUIPMENT AND PERFORM
ALL WORK INCLUDING RESTORATION FOR THE COMPLETED FACILITY READY FOR USE.
UNLESS OTHERWISE NOTED, SPECIFICATIONS FOR ALL WORK TO BE IN ACCORDANCE WITH
APPLICABLE STANDARDS AND CONSTRUCTION SPECIFICATIONS OF THE VIRGINIA
DEPARTMENT OF HEALTH, VIRGINIA DEPARTMENT OF ENVIRONMENTAL QUALITY, FREDERICK
COUNTY SANITATION AUTHORITY, THE CONTRACT DOCUMENTS AND THE VIRGINIA
DEPARTMENT OF TRANSPORTATION ROAD AND BRIDGE SPECIFICATIONS DATED JANUARY
2002; VIRGINIA DEPARTMENT OF TRANSPORTATION ROAD AND BRIDGE STANDARDS DATED
FEBRUARY 1, 2001; AND THE VIRGINIA DEPARTMENT OF TRANSPORTATION WORK AREA
PROTECTION MANUAL DATED JANUARY 1, 1996.
2. THE ENGINEER HAS ATTEMPTED TO LOCATE EXISTING SUBSURFACE UTILITIES; HOWEVER,
SUCH MAY EXIST THAT ARE NOT SHOWN. THE CONTRACTOR SHALL EXERCISE CARE IN THIS
WORK SO AS TO AVOID DAMAGE TO ANY UTILITIES. ANY DAMAGE SHALL BE THE
CONTRACTOR'S RESPONSIBILITY. THE CONTRACTOR SHALL NOTIFY ALL COMPANIES 72
HOURS PRIOR TO CONSTRUCTION. CALL "MISS UTILITY" 1-800-257-7777.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION STAKEOUT. ALL
DIMENSIONS, ELEVATIONS, AND LOCATIONS SHALL BE VERIFIED IN THE FIELD BY EACH
CONTRACTOR PRIOR TO BEGINNING THE WORK.
4. ANY UNUSUAL SUBSURFACE CONDITIONS ENCOUNTERED DURING THE COURSE OF THE WORK
SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER.
5. ALL GRADING FOR IMPROVEMENTS TO BE CONFINED TO THE PROJECT AREA. ANY WORK
PERFORMED OFFSITE IS THE CONTRACTOR'S RESPONSIBILITY.
6. CONTRACTOR SHALL OBTAIN, AT HIS EXPENSE, PERMITS FROM FREDERICK COUNTY FOR LAND
DISTURBANCE AND VIRGINIA DEPARTMENT OF TRANSPORTATION FOR WORK WITHIN VIRGINIA
DEPARTMENT OF TRANSPORTATION RIGHT-OF-WAY AND SHALL FAITHFULLY ADHERE TO THE
PERMIT CONDITIONS IMPOSED.
7. TEMPORARY AND PERMANENT EROSION CONTROL STRUCTURES AND METHODS TO BE IN
ACCORDANCE WITH THE VIRGINIA EROSION CONTROL GUIDELINES AND LOCAL ORDINANCES
AND TO BE UTILIZED DURING THE CONSTRUCTION PERIOD.
8. ALL EROSION CONTROL STRUCTURES SHOWN OR AS REQUIRED DURING CONSTRUCTION
SHALL BE CONTINUOUSLY MAINTAINED THROUGHOUT THE PERIOD IN WHICH AREAS ARE
DENUDED. AREAS SHOWN TO BE SURFACED ARE TO HAVE STONE BASE INSTALLED AT THE
EARLIEST POSSIBLE DATE AFTER ESTABLISHING GRADE. NO AREA IS TO REMAIN DENUDED
FOR MORE THAN SEVEN CALENDAR DAYS WHEN CONSTRUCTION IS NOT IN PROGRESS.
9. ALL UNPAVED AREAS OF THE SITE WHICH ARE DISTURBED BY THIS CONSTRUCTION SHALL BE
PROVIDED WITH FOUR INCH TOPSOIL, FERTILIZED, SEEDED, COMPACTED AND MULCHED.
SEED BED TO BE WATERED AND CARED FOR AS NECESSARY TO PROVIDE A GOOD LAWN
QUALITY GRASS COVER. AREAS NOT GRADED SHALL BE DISCED, LEVELED AND SEEDED TO
ACHIEVE LAWN CONDITIONS.
10. SANITARY GRAVITY SEWER, FORCE AND WATER MAINS ARE TO BE CONSTRUCTED IN
ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS AND SHALL ADDITIONALLY MEET ALL
REQUIREMENTS OF THE FREDERICK WATER STANDARDS AND SPECIFICATIONS. THE
CONTRACTOR SHALL COORDINATE WITH THIS AGENCY AND ARRANGE FOR INSPECTION BY
THE AUTHORITY.
11. CONTRACTOR SHALL CLEAN UP AND RESTORE DISTURBED AREAS IMMEDIATELY UPON
COMPLETION OF PIPE-LAYING IN THE AFFECTED AREA.
12. THE CENTERLINE OF ALL NEW SANITARY GRAVITY SEWER, FORCE AND WATER SHALL BE
MAINS STAKED BY CONTRACTOR AT ALL 100 FOOT STATIONS AND AT ALL BENDS. THE
CONTRACTOR SHALL NOT PROCEED WITH CONSTRUCTION UNTIL THE ALIGNMENT HAS BEEN
APPROVED BY THE OWNER.
13. DISINFECTION OF SANITARY GRAVITY SEWER AND FORCE MAIN ARE NOT REQUIRED.
14. ALL FIRE HYDRANTS SHALL CONFORM TO THE FREDERICK COUNTY SANITATION
SPECIFICATIONS PART III PARAGRAPH 5.
15. STORM PIPE LENGTHS SHOWN ON PLANS & REPORTS MAY NOT NECESSARILY ACCOUNT FOR
STRUCTURES ON EITHER END.
CONTRACTOR SHALL RESTORE ALL EXISTING RESIDENTIAL DRIVEWAYS AND BUSINESS
ENTRANCES TO THEIR ORIGINAL STATE, IF DAMAGED DURING CONSTRUCTION.
SITE DEVELOPMENT SUMMARY
PIN # 52-A-72
ZONING RA
SITE AREA 9.78 AC.
DISTURBED AREA 4,624 S.F.
SITE LOCATION 2774 NORTHWESTERN PIKE
PREVIOUSLY APPROVED SITE PLANS #56-98, #67-06, #11-09, & #29-22
MAGISTERIAL DISTRICT GAINESBORO
CURRENT USE CHURCH
PROPOSED USE CHURCH
FLOOD PLAIN FEMA FLOOD MAP #51069C0205E
eff. 1/29/2021 ZONE: X - AREA OF
MINIMAL FLOOD HAZARD
BUILDING SETBACKS REQUIRED PROVIDED
FRONT 60'145'+ (EX.)
SIDE 50'54.99
REAR 50'210'+ (EX.)
PARKING SETBACKS REQUIRED PROVIDED
STREET OR ROAD R/W 10'20'+ (EX.)
PROPERTY LINES 5'5'+ (EX.)
BUILDING ADDITION ALLOWED PROPOSED
AREA N/A 1,000 SF.
HEIGHT 35'LESS THAN 35'
NO NEW PARKING PROPOSED WITH THIS PLAN
NO NEW LANDSCAPING PROPOSED WITH THIS PLAN
NO NEW LIGHTING PROPOSED WITH THIS PLAN
NO NEW UTILITIES PROPOSED WITH THIS PLAN
NO NEW STORMWATER IMPROVEMENTS ARE PROPOSED WITH THIS PLAN TEST HOLE .........................
PARKING SPACES NUMBER .............
BUILDING WALL .....................
DOOR LOCATION .....................
LIMITS OF GRADING .................
BENCHMARK .........................
77
PROPOSED
CG-6R
TREE LINE .........................
TREE ..............................
SANITARY STRUCTURE LABEL ..........
WATER METER .......................
SPOT SHOT .........................
SIGN ..............................
FIRE HYDRANT ......................
STREET LIGHT ......................
UTILITY POLE ......................
WATER VALVE .......................
TRAFFIC SIGNAL POLE ...............
FENCE LINE ........................
UNDERGROUND TELEPHONE .............
OVERHEAD TELEPHONE ................
UNDERGROUND ELECTRIC ..............
OVERHEAD ELECTRIC .................
STORM STRUCTURE LABEL .............
WATERMAIN .........................
SANITARY SEWER ....................
STORM SEWER .......................
EDGE OF PAVEMENT ..................
CURB AND GUTTER ...................
CONTOURS ..........................
STREET CENTERLINE .................
PROPERTY LINE .....................
24
TRANS.CG-6
EXISTING
24
PAVEMENT BORING .....................
PAVEMENT CORES .....................
FORCE MAIN ..............
PW PWPROCESS WATER ..............
GAS LINE ........................
FIBER OPTIC ........................
FIRE LINE ........................
PW PW
FIRE RISER ......................
POST INDICATOR VALVE ......................
WV
STORM SEWER MANHOLE ................
SAN. SEWER MANHOLE ................
SF SQUARE FEET
SEC SECTION
RTE ROUTE
ROW RIGHT-OF-WAY
FT FEET
POLYVINYL CHLORIDE
REINFORCED CONCRETE PIPE
VIRGINIA DEPARTMENT OF TRANSPORTATION
WELDED WIRE MESH
POINT OF VERTICAL INTERSECTION
W/
FIRE HYDRANTF.H.
WV WATER VALVE
BEST MANAGEMENT PRACTICE
BEGIN VERTICAL CURVE STATION
BEGIN VERTICAL CURVE ELEVATION
END VERTICAL CURVE STATION
END VERTICAL CURVE ELEVATION
DROP INLET
DIAMETER
DUCTILE IRON PIPE
EROSION CONTROL
ELEVATION
END SECTION
FINISHED FLOOR ELEVATION
ELEV
F.F.E.
EVCS
EX
EVCE
ES
EXISTING
DIP
EA
EC
DIA
DI
EACH
BENCHMARK
CLEANOUT
CONCRETECONC
CL
CO
BVCS
BVCE
CLASS
BLDG
B.M.
BMP
BUILDING
STR
VERT
WWM
TYP
VDOT
RCP
SHT
STM
PVC
PVI
STRUCTURE
TYPICAL
VERTICAL
WITH
SHEET
STEAM
HORIZ
MECH
MIN
MSE
INV
MAX
G.V.
HORIZONTAL
INVERT
MAXIMUM
MECHANICAL
MINIMUM
MECHANICALLY STABILIZED EARTH
GATE VALVE
AREA DRAINAD
TRENCH DRAINTD
LIMITS OF DISTURBANCELOD
APPX. APPROXIMATELY
OVERHEAD ELECTRICOHE
UNDERGROUND ELECTRICUGE
UGT UNDERGROUND TELEPHONE
TELCO TELECOMMUNICATIONS
WWF WELDED WIRE FABRIC
CAST IRONCI
STAINLESS STEELSS
TREE PROTECTIONTP
NORTH BOUND LANENBL
SOUTH BOUND LANESBL
BW BOTTOM OF WALL
TOP OF WALLTW
ON CENTER EACH WAY
ON CENTEROC
OCEW
PROP PROPOSED
DIAMETERØ
MANHOLEMH
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
CWR
CWS CHILLED WATER SUPPLY
CHILLED WATER RETURN
MECHANICAL, ELECTRICAL, PLUMBINGMEP
MLP METAL LIGHT POLE
HANDICAP PARKINGHCP
BUILDING RESTRICTION LINEBRL
ABBREVIATIONS
ACRESAC
LF LINEAR FEET
F.H. ASSY FIRE HYDRANT ASSEMBLY
MSP METAL SIGN POLE
Sheet List Table
Sheet Number Sheet Title
1 Cover Sheet
2 Dimensional & Grading Plan
EMMANUEL BAPTIST CHURCH,STORAGE ADDITION2774 NORTHWESTERN PIKEWINCHESTER, VA 226032774 NORTHWESTERN PIKEWINCHESTER, VA 22603EMMANUEL BAPTIST CHURCHCOVER SHEET
50.00' LANDSCAPEBUFFER EASEMENT8" ROOF DRAIN
INV=98.3
8" ROOF DRAINDAYLIGHT
ROOF DRAIN
F.F.E. (99.96)
F.F.E. (100.02)
CO
BASEMENT (91.99)
TOP TANK
ELEV.=100.25
INV.=97.75
TANK LIDTANK LIDTANK LID
F.F.E.
(103.83)
F.F.E.(103.80)
F.F.E. (99.98)
COVERED ENTRANCE
COVERED ENTRANCE
F.F.E. (99.95)
EXISTING
VOLLEYBALLCOURT
EXISTINGFRAME
BUILDING
EX. FENCEWM
WELLCAPPROPANETANK115105105
100
95
9095
90
85
85
85
90
85
90
8590 909595100 100 10095
95
100
105
105
115
115
93
96
96 9594
96
97
9
8
99
99
9897
98
99
101
102
103
104
106
111
112
114116117118216 216 118 117 116
114
106 104
103
102
101
99
9
8
9
79694
9392918988878684 838281
818283848687
88
89 101102
103
104106114
116
117118
104
103
102
101
99
98
97
96
9493
92
91
89
88
878682
83
84
86
87
88
89 96979899101102103104
1009592
93
94
9910210199
G.F.E.109.00'
113 113112111 109108
107
106
107
108
109
110
110
52-A-73
EMMANUEL BAPTIST CHURCH
INST. #010007354
DB 681 PG 387
ZONED: RA
USE: RESIDENTIAL
52-A-76
FREDERICK & KELLY DONDERO
INST. #160011866
DB 328 PG 462
ZONED: RA
USE: RESIDENTIAL
52-A-74
PAUL M. & SUE A. LOCKHART
DB 697 PG 242
ZONED: RA
USE: RESIDENTIAL
52-A-78
DONALD L. & DONNA K. AMICK
DB 659 PG 361
ZONED: RA
USE: RESIDENTIAL
52-A-79
ALFRED M. & RUTH WILLIAMS
DB 250 PG 68
PARCEL 1
ZONED: RA
USE: RESIDENTIAL
52-A-80
ALFRED M. & RUTH WILLIAMS
DB 250 PG 68
PARCEL 2
52-A-82
ELSIE M. WILLIAMS
INST. #160000127
DB 242 PG 372
ZONED: RA
USE: RESIDENTIAL
52-A-81
ELSIE M. WILLIAMS
INST. #160000127
DB 244 PG 286
52-A-83
HESTON LUTTRELL
INST. #050000006
DB 893 PG 134
ZONED: RA
USE: RESIDENTIAL
52-A-84
HESTON LUTTRELL
INST. #050000006
DB 893 PG 134
ZONED: RA
USE: RESIDENTIAL
52-A-72
EMMANUEL BAPTIST CHURCH
DB 366 PG 544
ZONED: RA
USE: CHURCH
52-A-71
JOSE SANTOS & FLORIDA I. JU
A
R
E
Z
INST. #150008246
ZONED: RA
USE: RESIDENTIAL
52-A-68
JENNIFER L. & GRADY A. PAINT
E
R
INST. #1600011988
ZONED: RA
USE: RESIDENTIAL
52-A-66
KEVIN & JOY O'NEILL
INST. #140006922
ZONED: RA
USE: RESIDENTIAL
52-A-61
WINWOOD PROPERTIES II, LLC
INST. #14001067
ZONED: B2
USE: COMMERCIAL
ZONED: RA
USE: RESIDENTIAL
ZONED: RA
USE: RESIDENTIAL
EX
.
A
S
P
H
A
L
T
D
R
I
V
E
W
A
Y
NORTHWESTERN PIKE
EX. 1,200 S.F. GARAGE40'W x 30'D
EX. 12' WIDE GRAVELDRIVE, WITH 40'W x30'D GRAVEL LANDING
50' BUILDING USESIDE SETBACKPROP. STORAGE ROOM
F.F.E. 100.00'
1,000 SF
ROOF DRAIN
TO BE
RELOCATED
54.99'50.00'20.00'
SF
CE
PROVIDE
CONSTRUCTION
ENTRANCE WITH
WASH RACK
IF REQUIRED
99989799100 99 30
99 30
LIMITS OF
DISTURBED AREA
4,624 SF.U:\Accounts\EMBAP\EMBAP22001 - Emmanuel Baptist Church Minor Site Plan\DESIGN\_SHEETS\CS3000.dwg PLOTTED: 8/18/2022 12:41 PM, BY: Teri Hermen PLOTSTYLE: Pennoni NCS.stb PROJECT STATUS: ----APPROVED PERMIT DRAWINGS CS3000 BYNO.DATEREVISIONSEMBAP22001
AS SHOWN
TLH
2022-06-30
MMA
SHEET
APPROVED BY
OF2 2
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS PENNONI
ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND
EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK00 40'80' PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NORTHEMMANUEL BAPTIST CHURCH,STORAGE ADDITION2774 NORTHWESTERN PIKEWINCHESTER, VA 226032774 NORTHWESTERN PIKEWINCHESTER, VA 22603EMMANUEL BAPTIST CHURCHDIMENSIONAL & GRADING PLAN2022-08-18
EXISTING CONDITIONS NOTE:
EXISTING CONDITIONS INFORMATION SHOWN HEREON, IS FROM
APPROVED SITE PLAN. EXISTING CONDITIONS MAY DIFFER.
EROSION AND SEDIMENT
CONTROL LEGEND
NO.TITLE KEY SYMBOL
3.02 TEMPORARY STONE
CONSTRUCTION ENTRANCE CE
3.05 SILT FENCE SF
EROSION & SEDIMENT CONTROL NOTE:
CONSTRUCTION ENTRANCE AND SILT
FENCE SHALL BE INSTALLED AS THE
FIRST PHASE OF LAND DISTURBING
ACTIVITIES.