Loading...
HomeMy WebLinkAbout07-22 Site PlanSITE U:\Accounts\RRMMX\RRMMX21005 - Indian Hollow ES Renovation\DESIGN\_SHEETS\02-Design Development\CS0000 Cover Sheet.dwg PLOTTED: 3/25/2022 2:17 PM, BY: Liliana Hernandez PLOTSTYLE: Pennoni NCS.stb PROJECT STATUS: CONSTRUCTION DRAWINGSBYNO.DATEREVISIONSRRMMX21005 AS NOTED CJM 2021-11-18 RAMAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493&'3/$1SET LOCATION MAP Scale: 1" = 2000'NORTH&$// &$//%E)25E<28'I* ALWAYS CALL 811 BEFORE YOU DIG IN VIRGINIA SECTION 56-265.17 REQUIRES THREE WORKING DAYS NOTICE TO UTILITIES BEFORE YOU EXCAVATE, DRILL OR BLAST VIRGINIA UTILITY PROTECTION SERVICE, INC. TICKET NUMBER(S): PREPARED BY: PENNONI ASSOCIATES INC. 117 East Piccadilly Street Winchester, VA 22601 T 540.667.2139 F 540.665.0493  03/25/2022 FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VA. 22604COVER SHEETINDIAN HOLLOW ELEMENTARY SCHOOLMINOR RENOVATIONS AND REPAIRSCONSTRUCTION DRAWINGS1548 NORTH HAYFIELD RD. | WINCHESTER, VA. 22603GAINESBORO MAGISTERIAL DISTRICTPREPARED FOR: OWNER/DEVELOPER PO BOX 3508 WINCHESTER, VA. 22604 (540) 344-1212 I1'I$1+2//2:E/E0E1T$5<S&+22/ 0I1255E129$TI21S$1'5E3$I5S &21ST58&TI21'5$:I1*S ¬ SITE3/$1 *$I1ES%2520$*ISTE5I$/'IST5I&T)5E'E5I&.&281T<9I5*I1I$ 25I*S8%0ISSI21'$TET%' 5E9ISE'S8%0ISSI21'$TET%' RESPONSIBLE LAND DISTURBER THE RESPONSIBLE LAND DISTURBER IS THAT PARTY RESPONSIBLE FOR CARRYING OUT THE LAND DISTURBING ACTIVITY AS SET FORTH IN THE PLANS. NAME:_____________________________________________________ CERTIFICATION #:___________________________________________ DATE: _____________________________________________________ APPROVED BY FREDERICK COUNTY ZONING ADMINISTRATOR ________________________________________________________________________________ APPROVED BY DATE &S TOTAL SHEETS 17 S+EETI1'E; S+EET12S+EETTIT/E CS0000 COVER SHEET CS0001 GENERAL NOTES AND LEGENDS CS1000 EXISTING CONDITIONS PLAN CS1500 DEMOLITION PLAN CS2000 EROSION AND SEDIMENT CONTROL NARRATIVE CS2100 EROSION AND SEDIMENT CONTROL PLAN PHASE I CS2200 EROSION AND SEDIMENT CONTROL PLANS PHASE II CS2500 EROSION AND SEDIMENT CONTROL DETAILS CS2501 EROSION AND SEDIMENT CONTROL DETAILS CS4000 OVERALL PLAN CS4001 SITE PLAN CS4100 GRADING PLAN CS4500 SITE DETAILS CS5200 DRAINAGE DIVIDES CS5300 WATER QUALITY CS5400 WATER QUANTITY CS6100 STORM PROFILES LOCAL UTILITIES SHENANDOAH VALLEY ELECTRIC CO-OP 3463 VALLEY PIKE WINCHESTER, VA 22602 (540) 450-2051 / (540) 450-0111 VERIZON 404 HILLANDALE LANE WINCHESTER, VIRGINIA 22602 (540) 665-3156 COMCAST COMMUNICATIONS 195 RAINVILLE ROAD WINCHESTER, VIRGINIA 22602 (540) 504-0942 WASHINGTON GAS 350 HILLANDALE LN. WINCHESTER, VIRGINIA 22602 (540) 868-7913 FREDERICK WATER 315 TASKER ROAD STEPHENS CITY, VIRGINIA 22655 (540) 868-1061 DAVID L. FRANK Lic. No.1061 ESTI0$TE'48$1TITIES SITE IMPROVMENTS EMERGENCY ACCESS ROAD 704 LF SIDEWALK REPLACEMENT 120 LF REMOVABLE BOLLARDS 6 CT VDOT CLASS 1 RIPRAP 180 SF EC-3 LINING 147 LF STORM SEWER STRUCTURES DI-1 INLET 1 CT DI-7 INLET 1 CT 15" HDPE END SECTIONS 4 CT STORM SEWER PIPES 12" PVC SDR-35 140 LF 15" HDPE 68 LF 4" UNDER-DRAIN (PERFORATED)491 4" UNDER-DRAIN (NON-PERFORATED)219 LF WATER QUALITY TOTAL PHOSPHOROUS LOAD REDUCTION REQUIRED 0.02 LBS/YR PROJECT DESCRIPTION THIS IS AN EXISTING ELEMENTARY SCHOOL BUILDING LOCATED AT 1548 HAYFIELD RD. SITE IMPROVEMENTS GENERALLY INCLUDE RENOVATION AND EXPANSION OF EXISTING ELEMENTARY SCHOOL BUILDING, TWO NEW MOBILE CLASSROOM BUILDINGS, REVISED GRADING, INTERNAL VEHICULAR CIRCULATION FOR COMMERCIAL AND PASSENGER VEHICLES, STORM WATER MANAGEMENT AND ON-SITE DRAINAGE. AGENCY REVIEW / APPROVAL TRACKING 02-04-2022 PLANNING, FIRE MARSHAL, INSPECTIONS, PUBLIC WORKS, 03-11-2022 PUBLIC WORKS (APPROVAL) 03-25-2022 PLANNING, FIRE MARSHAL, INSPECTIONS, GIS GENERAL CONSTRUCTION NOTES 1.THE CONTRACTOR SHALL FURNISH ALL MATERIALS, LABOR AND EQUIPMENT AND PERFORM ALL WORK INCLUDING RESTORATION FOR ALL IMPROVEMENTS SHOWN OR IMPLIED AS NECESSARY FOR THE COMPLETED FACILITY READY FOR USE. UNLESS OTHERWISE NOTED, SPECIFICATIONS FOR ALL WORK TO BE IN ACCORDANCE WITH APPLICABLE STANDARDS AND CONSTRUCTION SPECIFICATIONS OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION, VIRGINIA DEPARTMENT OF HEALTH, ECONOMIC DEVELOPMENT AUTHORITY, AND THE CONTRACT DOCUMENTS. 2.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION STAKEOUT. ALL DIMENSIONS, ELEVATIONS AND LOCATIONS SHALL BE VERIFIED IN THE FIELD BY EACH CONTRACTOR PRIOR TO BEGINNING THE WORK. THE ENGINEER WILL APPROVE ALL CUT SHEETS. 3.CONSTRUCTION ACTIVITIES SHALL BE LIMITED TO THE HOURS OF 8:00 AM TO 5:00 PM. FCPS MAY EXTEND THE ALLOWED WORK HOURS. 4.ANY UNUSUAL SUBSURFACE CONDITIONS ENCOUNTERED DURING THE COURSE OF THE WORK SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER AND/OR THE OWNER. 5.CONTRACTOR TO OBTAIN, AT HIS EXPENSE, ALL PERMITS REQUIRED OF THIS WORK PRIOR TO COMMENCING CONSTRUCTION AND SHALL FAITHFULLY ADHERE TO THE PERMIT CONDITIONS IMPOSED. 6.ALL GRADING FOR IMPROVEMENTS TO BE CONFINED TO THE PROJECT AREA. ANY WORK PERFORMED OFFSITE IS THE CONTRACTOR'S RESPONSIBILITY. DUE TO THE PROXIMITY OF THE PROJECT TO EXISTING STRUCTURES AND UTILITIES, BLASTING WILL NOT BE ALLOWED. 7.CUTSHEETS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO CONSTRUCTION. ALL CUTSHEETS SHOULD SHOW EXISTING GROUND ELEVATIONS AT CENTERLINE OF UTILITY, STRUCTURE OR ROAD, AND OFFSET HUB ELEVATION. 8.LOCATIONS OF UTILITIES SHOWN ARE APPROXIMATE. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING THE EXACT LOCATION, VERTICALLY AND HORIZONTALLY, OF THE UTILITIES PRIOR TO ANY EXCAVATION OR CONSTRUCTION. THE CONTRACTOR SHALL CONTACT "MISS UTILITY" AND ALL APPLICABLE UTILITY COMPANIES FOR CLEARANCE PRIOR TO EXCAVATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADHERING TO THE COMMONWEALTH OF VIRGINIA UNDERGROUND UTILITY DAMAGE PREVENTION ACT, CHAPTER 10, TITLE 56 OF THE CODE OF VIRGINIA. 9.CONTRACTOR SHALL BE RESPONSIBLE FOR IMPLEMENTING AND MAINTAINING ALL EROSION AND SEDIMENT CONTROL MEASURES NECESSARY DURING CONSTRUCTION IN ACCORDANCE WITH CURRENT STATE AND LOCAL REGULATIONS. DISTURBED AREAS SHALL NOT REMAIN DENUDED FOR MORE THAN SEVEN (7) CALENDAR DAYS WHEN CONSTRUCTION IS NOT IN PROGRESS. DURING CONSTRUCTION, ALL STORM SEWER INLETS SHALL BE PROTECTED BY INLET PROTECTION, AND SHALL BE MAINTAINED AND MODIFIED AS REQUIRED BY CONSTRUCTION PROGRESS. CONTRACTOR SHALL CONTACT THE COUNTY BUILDING INSPECTIONS OFFICE AT (540) 636-9973 TO SCHEDULE INSPECTIONS. 10.CONTRACTOR SHALL PROVIDE ADEQUATE MEANS OF CLEANING MUD FROM TRUCKS AND/OR OTHER EQUIPMENT PRIOR TO ENTERING PUBLIC STREETS AND/OR EXISTING PARKING LOTS AND OTHER PAVED AREAS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CLEAN STREETS, ALLAY DUST, AND TO TAKE WHATEVER MEASURES NECESSARY TO ENSURE THAT THE STREETS ARE MAINTAINED IN A CLEAN, MUD AND DUST FREE CONDITION AT ALL TIMES. 11.ANY STREET OR UTILITIES DAMAGED BY CONTRACTOR OR SUB-CONTRACTOR SHALL BE SOLE RESPONSIBILITY OF THE PRIMARY CONTRACTOR AND PROPERLY AND IMMEDIATELY REPAIRED BY THE CONTRACTOR. SUCH REPAIRS SHALL BE TO THE ORIGINAL CONDITION, IN COMPLIANCE WITH THE TOWN'S CONSTRUCTION STANDARDS & SPECIFICATIONS, AND TO THE SATISFACTION OF THE TOWN INSPECTOR. 12.ALL PRE-CAST CONCRETE STRUCTURES SHALL BE A MINIMUM 4000 PSI AT 28 DAYS. 13.THE CONTRACTOR IS RESPONSIBLE FOR ADJUSTMENT OF ALL UTILITY BOXES, VAULTS, OR OTHER APPURTENANCES TO NEW FINISHED GRADE ELEVATIONS. 14.CONTRACTOR TO RELOCATE ALL SIGNS AND UTILITIES REQUIRED FOR THIS WORK. 15.ANY PLANNED DISRUPTIONS OF OR TIE INS TO EXISTING UTILITIES SHALL BE COORDINATED WITH THE APPROPRIATE UTILITY OWNER. WITH THE EXCEPTION OF EMERGENCIES, THERE SHALL BE A MINIMUM OF 24 HOURS NOTICE GIVEN BY THE CONTRACTOR TO THE OWNER AFFECTED BY UTILITY INTERRUPTIONS. 16.THE UNAUTHORIZED USE OF WATER WITHOUT DUE COMPENSATION IS ILLEGAL. NO PERSON SHALL CONNECT TO OR DO ANY WORK ON THAT PORTION OF THE SYSTEM OWNED BY THE OWNER UNLESS WRITTEN AUTHORIZATION IS RECEIVED PRIOR TO COMMENCING WORK. 17.CONSTRUCTION LIMITS SHALL BE PROPERTY LINES OR AS INDICATED BY PLAN REQUIREMENTS AND SHALL BE STAKED OR FLAGGED IN THE FIELD PRIOR TO CONSTRUCTION. 18.CONSTRUCTION SHALL CONFORM TO THE AMERICAN WITH DISABILITIES ACT (ADA) REQUIREMENTS. 19.REGISTERED LAND DISTURBER TO SUBMIT REPORTS TO BUILDING INSPECTOR ON A REGULAR BASIS AS REQUIRED BY FREDERICK COUNTY. 20.THE CONTRACTOR SHALL COORDINATE WITH THE INDIVIDUAL LOT OWNERS TO RELOCATE THE EXISTING MAIL BOXES THAT ARE AFFECTED BY THE PROPOSED IMPROVEMENTS. 21.ALL UTILITIES WILL BE LOCATED UNDERGROUND. 22.TEST PITS ARE REQUIRED ON ALL UTILITY LINES AS NOTED ON PLANS. 23.FIELD ADJUSTMENTS TO UTILITY INFRASTRUCTURE SHALL BE AS REQUIRED BY AND PER THE OWNER'S DIRECTION. 24.EXISTING MANHOLE FRAMES AND COVERS AND VALVE BOXES AND COVERS TO REMAIN SHALL BE ADJUSTED OR RECONSTRUCTED, AS NECESSARY, TO MATCH FINISHED GRADES. 25.REMOVAL OF ANY FUEL STORAGE TANKS, IF PRESENT, SHALL BE IN CONFORMANCE WITH LOCAL, STATE, AND FEDERAL REGULATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL RELATED PERMITS PRIOR TO CONSTRUCTION. FIRE AND RESCUE 1. BURNING OF CONSTRUCTION DEBRIS AND CLEARING AND GRUBBING DEBRIS ON SITE IS PROHIBITED. 2. ACCESS FOR EMERGENCY VEHICLES MUST BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION. CG-6 CONCRETE SIDEWALK LIMITS OF CLEARING AND GRADING STORM SEWER WATERLINE CONTOURS UNDERGROUND ELECTRIC SERVICE SANITARY SEWER WITH MANHOLE PROPERTY LINE UTILITY POLE SIGN POST LEGEND FIRE HYDRANT ASSEMBLY GAS LINE HY DSF SQUARE FEET SEC SECTION RTE ROUTE ROW RIGHT-OF-WAY FT FEET POLYVINYL CHLORIDE REINFORCED CONCRETE PIPE VIRGINIA DEPARTMENT OF TRANSPORTATION WELDED WIRE MESH POINT OF VERTICAL INTERSECTION W/ FIRE HYDRANTF.H. WV WATER VALVE BEST MANAGEMENT PRACTICE BEGIN VERTICAL CURVE STATION BEGIN VERTICAL CURVE ELEVATION END VERTICAL CURVE STATION END VERTICAL CURVE ELEVATION DROP INLET DIAMETER DUCTILE IRON PIPE EROSION CONTROL ELEVATION END SECTION FINISHED FLOOR ELEVATION ELEV F.F.E. EVCS EX EVCE ES EXISTING DIP EA EC DIA DI EACH BENCHMARK CLEANOUT CONCRETECONC CL CO BVCS BVCE CLASS BLDG B.M. BMP BUILDING STR VERT WWM TYP VDOT RCP SHT STM PVC PVI STRUCTURE TYPICAL VERTICAL WITH SHEET STEAM HORIZ MECH MIN MSE INV MAX G.V. HORIZONTAL INVERT MAXIMUM MECHANICAL MINIMUM MECHANICALLY STABILIZED EARTH GATE VALVE AREA DRAINAD TRENCH DRAINTD LIMITS OF DISTURBANCELOD APPX.APPROXIMATELY OVERHEAD ELECTRICOHE UNDERGROUND ELECTRICUGE UGT UNDERGROUND TELEPHONE TELCO TELECOMMUNICATIONS WWF WELDED WIRE FABRIC CAST IRONCI STAINLESS STEELSS TREE PROTECTIONTP NORTH BOUND LANENBL SOUTH BOUND LANESBL BW BOTTOM OF WALL TOP OF WALLTW ON CENTER EACH WAY ON CENTEROC OCEW PROP PROPOSED DIAMETERØ MANHOLEMH FOR FUEL OIL RETURN FOS FUEL OIL SUPPLY CWR CWS CHILLED WATER SUPPLY CHILLED WATER RETURN MECHANICAL, ELECTRICAL, PLUMBINGMEP ABBREVIATIONS MLP METAL LIGHT POLE MSP METAL SIGN POLE F.H. ASSY FIRE HYDRANT ASSEMBLY HANDICAP PARKINGHCP BUILDING RESTRICTION LINEBRL ASPHALT PAVEMENT CG-6R REVERSE CURB FEMA FLOOD MAP # 51069C0200E eff. 1/29/2021 ZONE "X" AREA OF MINIMAL FLOOD HAZARD SITE DEVELOPMENT SUMMARY SCHOOL TAX IDENTIFICATION NUMBERS CURRENT ZONING CURRENT USE PROPOSED USE FLOOD PLAIN SITE AREA TOTAL DISTURBED AREA 40-(A)-31A RA SCHOOL 19.51 ACRES 3.95 ACRES PLANNING AND DEVELOPMENT NOTES 1.THERE ARE NO PROPOSED CHANGES TO EXISTING LANDSCAPING, LIGHTING, OR SIGNAGE. 2.FOR EXISTING LANDSCAPING, LIGHTING, OR SIGNAGE DETAILS REFER TO SP #14-86 AND SP #17-10 APPROVED PLANS. 35FTMAX BUILDING HEIGHT FRONT RIGHT SIDE LEFT SIDE REAR YARDS/SETBACKS 60' 100' 100' 100' REQUIRED 235.9' ± 224.4' ± 173.0' ± 334.6' ± PROVIDED U:\Accounts\RRMMX\RRMMX21005 - Indian Hollow ES Renovation\DESIGN\_SHEETS\02-Design Development\CS0001 General Notes.dwg PLOTTED: 3/25/2022 1:34 PM, BY: Liliana Hernandez PLOTSTYLE: Pennoni NCS.stb PROJECT STATUS: CONSTRUCTION DRAWINGSBYNO.DATEREVISIONSRRMMX21005 AS NOTED CJM 2021-11-18 RAMAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493100% CD PLAN SET 01/31/2022  03/25/2022 FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VA. 22604GENERAL NOTES AND LEGENDSCS0001 TOTAL SHEETS 17INDIAN HOLLOW ELEMENTARY SCHOOLMINOR RENOVATIONS AND REPAIRSCONSTRUCTION DRAWINGS1548 NORTH HAYFIELD RD. | WINCHESTER, VA. 22603GAINESBORO MAGISTERIAL DISTRICTDAVID L. FRANK Lic. No.1061 INV. ( 7 6 0 . 0 1 ) 1 5 " R C P I N V . ( 7 6 1 . 9 7 ) INV. (76 2 . 3 1 )12" PVCINV. (766.82)12" PV C INV . ( 7 6 7 . 5 8 ) CO MB INV. (75 8 . 3 9 ) INV. ( 7 5 7 . 9 2 ) 18" RC P INV. (758.02)18" RCPINV. (759.75)GRATE (77 9 . 0 0 ) IN (767.0 0 ) OUT (766. 8 0 ) GRATE ( 7 8 3 . 3 7 ) OUT (782 . 4 7 ) (4)4" P E P P I P E S (DIR. U N K . ) RIM (767 . 1 1 ) IN (761. 3 1 ) OUT (761 . 0 1 ) RIM ( 7 6 7 . 4 1 ) IN ( 7 6 4 . 1 1 ) OUT ( 7 6 4 . 0 1 ) RIM (7 7 9 . 6 8 ) IN (77 2 . 0 8 ) OUT (771 . 9 8 ) RIM ( 7 7 6. 5 2)IN (77 0. 2 2) OUT ( 7 7 0. 0 2) RIM ( 7 7 2 . 6 5 ) IN ( 7 6 7 . 6 5 ) OU T ( 7 6 7 . 4 5 )ASPHALTCONC. W A L K CONC. W A L K ASPHA L T ASPHA L T C O N C . W A L K CONC. WALKC O N C . W A L K ASPH A L T ASPHAL T P A R K I N G L O T ASPHALTMETAL GUARDRA I L ASPHALTASPHALT A S P H A L T PLAY G R O U N D PLAY G R O U N D PLAYGROUN D PLAY G R O U N D PLAYGROUN D PLAYGROUNDPLAYGRO U N D PLAYGROUND PLAYG R O U N D ASPHA L T T R A C K ASPHA L T T R A C K PLAYG R O U N DCONC. WALKCONCRE T E A S P H A L T CONC. WALKCONC. WAL K CONC.GRASS GRAS S GRAS S GRAS S GRAS S GRAS S GRAS S GRAS S GRAS S GRASS GRASS METAL R A M P C O N C . W A L K E X . M O B I L E C L A S S R O O M 4 (9 1 0 S F ) E X . M O B I L E C L A S S R O O M 1 (9 1 0 S F ) E X . M O B I L E C L A S S R O O M 2 (9 5 2 S F ) E X . M O B I L E C L A S S R O O M 3 (9 5 2 S F ) C O N C . BA T T I N G CA G E 15" PV C RIM (767 . 1 0 ) INV. (7 6 2 . 6 0 ) EXISTING WWTP 6" PV C 6" PVC 30" RCP 30" RCP30" RCP6" PV C 15" R C P A/CA/C CONC R E T E GENE R A T O R BUILD I N G FUEL TANK F.F.E. ( 7 8 0 . 4 9 ) F.F.E. ( 7 8 0 . 4 7 ) F.F.E. ( 7 8 0 . 4 9 ) F.F.E. ( 7 8 0 . 5 1 ) MPMP WP CO MP WPWP WP CO CO COCO GRATE (77 8 . 6 8 ) OUT (769 . 3 8 )GRATE (777.28)IN (768.28)OUT (768.08)PIN 40 - A - 3 1 A COUNTY S C H O O L B O A R D O F F R E D E R I C K C O U N T Y VIRGIN I A DB 605 P G 7 8 5 ZONED: R A U S E : S C H O O L PIN 40-A-37 ASHALLEN PROPERTIES, LLC INST. 200012199 ZONED: RA USE: AGRICULTURAL PIN 40-A-37 ASHALLEN PROPERTIES, LLC INST. 200012199 ZONED: RA USE: AGRICULTURAL PIN 40-A-1 GERRY O FARM, LLC INST. 080000074 ZONED: RA USE: AGRICULTURAL PIN 40-A-31 CRAIG PEARRELL INST. 200004147 ZONED: RA USE: RESIDENTIAL PIN 40-A-32A HERBERT L. FELTNER DB 296 PG 108 ZONED: RA USE: RESIDENTIAL PIN 40-A-34 HERBERT L. FELTNER DB 312 PG 654 ZONED: RA USE: RESIDENTIAL PIN 40-A-10A LEONI WERTHEIM INST. 110009185 ZONED: RA USE: AGRICULTURAL VA. SEC. RTE. 600N. HAYFIELD ROADBRICK S C H O O L B U I L D I N G "INDIA N H O L L O W E L E M E N T A R Y S C H O O L " (59,89 0 S F ) O V E R H A N G A/C RIM (7 7 7 . 2 2 ) OUT (771 . 9 2 ) INDIA N H O L L O W R O A D CONC. LOADIN GRAMP FUEL STOR A G E U/G OI L T A N K (APPR O X . ) EX CTR L P A N E L EXISTING TREELINE EXISTING TREELINE APPROX . L O C A T I O N OF TIME C A P S U L E APPRO X . LOCA T I O N OF EX . LAND M A R K TREES WHH (AP P R O X . ) ASPHAL T PARKIN G L O T EX. ADA ACCESSIBLE ROUTE ASPHAL T PARKING L O T WP w/ ELEC. OUTLET 41B 13B 13B 13B41B 3C 3C 40B 13C 14C 17E 41D 41C 3C 13B 41B 41C 41C MAP UNIT SYMBOL MAP UNIT NAME HSG KFACTOR RUNOFF/EROSION POTENTIAL SHRINK-SWELL POTENTIAL 3C BLAIRTON SILT LOAM, 7-15% SLOPES C .43 MEDIUM / RAPID LOW 13B FRANKSTOWN CHANNERY SILT LOAM, 2-7% SLOPES B .37 MEDIUM MODERATE 13C FRANKSTOWN CHANNERY SILT LOAM, 7-15% SLOPES B .37 MEDIUM MODERATE 14C FREDERICK-POPLIMENTO LOAMS, 7-15% SLOPES B/C .32 RAPID / SEVERE HIGH 17E FREDERICK-POPLIMENTO-ROCK OUTCROP COMPLEX, 15-45% SLOPES B/C .28 RAPID / SEVERE HIGH 40B TIMBERVILLE SILT LOAM, 2-7% SLOPES, FREQUENTLY FLOODED B .32 MEDIUM / MODERATE LOW / MODERATE 41B WEIKERT-BERKS CHANNERY SILT LOAMS, 3-8% SLOPES C/D .28 MEDIUM / MODERATE LOW 41C WEIKERT-BERKS CHANNERY SILT LOAMS, 8-15% SLOPES C/D .28 RAPID / SEVERE LOW 41D WEIKERT-BERKS CHANNERY SILT LOAMS, 15-25% SLOPES C/D .28 RAPID LOW U:\Accounts\RRMMX\RRMMX21005 - Indian Hollow ES Renovation\DESIGN\_SHEETS\02-Design Development\CS1000 Existing Conditions Plan.dwg PLOTTED: 3/25/2022 1:34 PM, BY: Liliana Hernandez PLOTSTYLE: Pennoni NCS.stb PROJECT STATUS: CONSTRUCTION DRAWINGSBYNO.DATEREVISIONSRRMMX21005 AS NOTED CJM 2021-11-18 RAMAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK00 50'100' GRAPHIC SCALE 1"=50'PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NORTH100% CD PLAN SET 01/31/2022  03/25/2022 FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VA. 22604EXISTING CONDITIONS PLANCS1000 TOTAL SHEETS 17INDIAN HOLLOW ELEMENTARY SCHOOLMINOR RENOVATIONS AND REPAIRSCONSTRUCTION DRAWINGS1548 NORTH HAYFIELD RD. | WINCHESTER, VA. 22603GAINESBORO MAGISTERIAL DISTRICT1.TOPOGRAPHIC INFORMATION SHOWN HEREON IS BASED ON AN ACTUAL FIELD SURVEY COMPLETED JULY 15, 2021. 2.ANY UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. THE SURVEYOR MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM INFORMATION AVAILABLE. 3.HORIZONTAL ORIENTATION IS BASED ON VA. NAD 83 NORTH ZONE STATE GRID; VERTICAL DATUM IS BASED ON NAVD 88 ELEVATIONS ESTABLISHED USING GPS METHODS. Marsh & Legge Land Surveyors, P.L.C. 560 NORTH LOUDOUN STREET ~ WINCHESTER, VIRGINIA 22601 PHONE (540) 667-0468 ~ FAX (540) 667-0469 ~ EMAIL office@marshandlegge.com www.marshandlegge.com DRAINAGE MANHOLE HANDICAP PARKING SIGN INVERT MAIL BOX METAL SIGN POST POLYVINYLCHLORIDE PIPE REINFORCED CONCRETE PIPE SANITARY MANHOLE U/G WATER LINE U/G ELECTRIC LINE U/G TELEPHONE LINE FENCE ABBREVIATION DEFINITION CLUSTER CLEAN OUT ELECTRIC CONTROL BOX ELECTRIC HANDHOLE ELECTRIC METER FINISHED FLOOR ELEVATION FIRE HYDRANT GUY ANCHOR METAL LIGHT POLE METAL POST NO PARKING SIGN TELEPHONE HANDHOLE TRIPLET TELEPHONE RISER BOX TWIN WOOD POST WOOD POWER POLE WATER VALVE DOGWOOD ELM MAPLE TREE PINE SPRUCE LEGEND DAVID L. FRANK Lic. No.1061 INV. ( 7 6 0 . 0 1 ) 1 5 " R C P I N V . ( 7 6 1 . 9 7 ) INV. (76 2 . 3 1 )12" PVCINV. (766.82)12" PV C INV . ( 7 6 7 . 5 8 ) CO MB INV. (75 8 . 3 9 ) INV. ( 7 5 7 . 9 2 ) 18" RC P INV. (758.02)18" RCPINV. (759.75)GRATE (77 9 . 0 0 ) IN (767.0 0 ) OUT (766. 8 0 ) GRATE ( 7 8 3 . 3 7 ) OUT (782 . 4 7 ) (4)4" P E P P I P E S (DIR. U N K . ) RIM (767 . 1 1 ) IN (761. 3 1 ) OUT (761 . 0 1 ) RIM ( 7 6 7 . 4 1 ) IN ( 7 6 4 . 1 1 ) OUT ( 7 6 4 . 0 1 ) RIM (7 7 9 . 6 8 ) IN (77 2 . 0 8 ) OUT (771 . 9 8 ) RIM ( 7 7 6. 5 2)IN (77 0. 2 2) OUT ( 7 7 0. 0 2) RIM ( 7 7 2 . 6 5 ) IN ( 7 6 7 . 6 5 ) OU T ( 7 6 7 . 4 5 )ASPHALTCONC. W A L K CONC. W A L K ASPHA L T ASPHA L T C O N C . W A L K CONC. WALKC O N C . W A L K ASPH A L T ASPHAL T P A R K I N G L O T ASPHALTMETAL GUARDRA I L ASPHALTASPHALT A S P H A L T PLAY G R O U N D PLAY G R O U N D PLAYGROUN D PLAY G R O U N D PLAYGROUN D PLAYGROUNDPLAYGRO U N D PLAYGROUND PLAYG R O U N D ASPHA L T T R A C K ASPHA L T T R A C K PLAYG R O U N DCONC. WALKCONCRE T E A S P H A L T CONC. WALKCONC. WALK CONC.GRASS GRAS S GRAS S GRAS S GRAS S GRAS S GRAS S GRAS S GRAS S GRASS GRASS METAL R A M P C O N C . W A L K E X . M O B I L E C L A S S R O O M 4 (9 1 0 S F ) E X . M O B I L E C L A S S R O O M 1 (9 1 0 S F ) E X . M O B I L E C L A S S R O O M 2 (9 5 2 S F ) E X . M O B I L E C L A S S R O O M 3 (9 5 2 S F ) C O N C . BA T T I N G CA G E 15" PV C RIM (767 . 1 0 ) INV. (7 6 2 . 6 0 ) EXISTING WWTP 6" PV C 6" PVC 30" RCP 30" RCP30" RCP6" PV C 15" R C P A/CA/C CONC R E T E GENE R A T O R BUILD I N G FUEL TANK F.F.E. ( 7 8 0 . 4 9 ) F.F.E. ( 7 8 0 . 4 7 ) F.F.E. ( 7 8 0 . 4 9 ) F.F.E. ( 7 8 0 . 5 1 ) MPMP WP CO MP WPWP WP CO CO COCO GRATE (77 8 . 6 8 ) OUT (769 . 3 8 )GRATE (777.28)IN (768.28)OUT (768.08)PIN 40 - A - 3 1 A COUNTY S C H O O L B O A R D O F F R E D E R I C K C O U N T Y VIRGIN I A DB 605 P G 7 8 5 ZONED: R A U S E : S C H O O L PIN 40-A-37 ASHALLEN PROPERTIES, LLC INST. 200012199 ZONED: RA USE: AGRICULTURAL PIN 40-A-37 ASHALLEN PROPERTIES, LLC INST. 200012199 ZONED: RA USE: AGRICULTURAL PIN 40-A-1 GERRY O FARM, LLC INST. 080000074 ZONED: RA USE: AGRICULTURAL PIN 40-A-31 CRAIG PEARRELL INST. 200004147 ZONED: RA USE: RESIDENTIAL PIN 40-A-32A HERBERT L. FELTNER DB 296 PG 108 ZONED: RA USE: RESIDENTIAL PIN 40-A-34 HERBERT L. FELTNER DB 312 PG 654 ZONED: RA USE: RESIDENTIAL PIN 40-A-10A LEONI WERTHEIM INST. 110009185 ZONED: RA USE: AGRICULTURAL VA. SEC. RTE. 600N. HAYFIELD ROADBRICK S C H O O L B U I L D I N G "INDIA N H O L L O W E L E M E N T A R Y S C H O O L " (59,89 0 S F ) O V E R H A N G A/C RIM (7 7 7 . 2 2 ) OUT (771 . 9 2 ) INDIA N H O L L O W R O A D CONC. LOADIN GRAMP FUEL STOR A G E U/G OI L T A N K (APPR O X . ) IRT 9003 N=7134993.816 E=11543783.215 ELEV.=770.79 IRT 9004 N=7135016.160 E=11543499.058 ELEV.=767.55 EX CTR L P A N E L EXISTING TREELINE EXISTING TREELINE APPROX . L O C A T I O N OF TIME C A P S U L E APPRO X . LOCA T I O N OF EX . LAND M A R K TREES WHH (AP P R O X . ) ASPHAL T PARKIN G L O T EX. ADA ACCESSIBLE ROUTE ASPHALT PARKING L O T WP w/ ELEC. OUTLET EX. BUCKET OF FUN POLE TO BE RELOCATED X UNDERGROUND ELECTRIC TO BE ABANDONED IN PLACE EXISTING SIDEWALK TO BE REMOVED AND REPLACED EXISTING SIDEWALK TO BE REMOVED AND REPLACED OVERHANG POLE/FOOTER SUBGRADE REPAIR ANTENNA TO BE REMOVED FUEL TANK TO BE REMOVED A/C UNITS AND UNDERGROUNG OIL TANK TO BE REMOVED TRANSFORMER TO BE REMOVED AND REPLACED RELOCATE EX. 4" CONDUIT TO 30" BELOW PROP. FINISHED GRADE EXISTING RETAINING WALL AND SIDEWALK TO REMAIN GUARDRAIL TO BE REMOVED GATE, EXTERIOR HAND RAILING, HARDWARE, CMU PIERS AND CAPS TO BE REMOVED LANDSCAPING & BERMING TO BE REMOVED LANDSCAPING & BERMING TO BE REMOVED EX. PLANTERS TO REMAIN U:\Accounts\RRMMX\RRMMX21005 - Indian Hollow ES Renovation\DESIGN\_SHEETS\02-Design Development\CS1500 Demolition Plan.dwg PLOTTED: 3/25/2022 1:34 PM, BY: Liliana Hernandez PLOTSTYLE: Pennoni NCS.stb PROJECT STATUS: CONSTRUCTION DRAWINGSBYNO.DATEREVISIONSRRMMX21005 AS NOTED CJM 2021-11-18 RAMAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK00 50'100' GRAPHIC SCALE 1"=50'PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NORTH100% CD PLAN SET 01/31/2022  03/25/2022 FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VA. 22604DEMOLITION PLANCS1500 TOTAL SHEETS 17INDIAN HOLLOW ELEMENTARY SCHOOLMINOR RENOVATIONS AND REPAIRSCONSTRUCTION DRAWINGS1548 NORTH HAYFIELD RD. | WINCHESTER, VA. 22603GAINESBORO MAGISTERIAL DISTRICTNOTES: 1.DEMOLITION WILL BE IN ACCORDANCE WITH PROJECT PHASING PLAN DAVID L. FRANK Lic. No.1061 9VAC25-840-40. MINIMUM STANDARDS. A VESCP MUST BE CONSISTENT WITH THE FOLLOWING CRITERIA, TECHNIQUES AND METHODS: 1.PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN SEVEN DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN DORMANT FOR LONGER THAN 14 DAYS. PERMANENT STABILIZATION SHALL BE APPLIED TO AREAS THAT ARE TO BE LEFT DORMANT FOR MORE THAN ONE YEAR. 2.DURING CONSTRUCTION OF THE PROJECT, SOIL STOCK PILES AND BORROW AREAS SHALL BE STABILIZED OR PROTECTED WITH SEDIMENT TRAPPING MEASURES. THE APPLICANT IS RESPONSIBLE FOR THE TEMPORARY PROTECTION AND PERMANENT STABILIZATION OF ALL SOIL STOCKPILES ON SITE AS WELL AS BORROW AREAS AND SOIL INTENTIONALLY TRANSPORTED FROM THE PROJECT SITE. 3.A PERMANENT VEGETATIVE COVER SHALL BE ESTABLISHED ON DENUDED AREAS NOT OTHERWISE PERMANENTLY STABILIZED. PERMANENT VEGETATION SHALL NOT BE CONSIDERED ESTABLISHED UNTIL A GROUND COVER IS ACHIEVED THAT IS UNIFORM, MATURE ENOUGH TO SURVIVE AND WILL INHIBIT EROSION. 4.SEDIMENT BASINS AND TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS AND OTHER MEASURES INTENDED TO TRAP SEDIMENT SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND-DISTURBING ACTIVITY AND SHALL BE MADE FUNCTIONAL BEFORE UPSLOPE LAND DISTURBANCE TAKES PLACE. 5.STABILIZATION MEASURES SHALL BE APPLIED TO EARTHEN STRUCTURES SUCH AS DAMS, DIKES AND DIVERSIONS IMMEDIATELY AFTER INSTALLATION. 6.SEDIMENT TRAPS AND SEDIMENT BASINS SHALL BE DESIGNED AND CONSTRUCTED BASED UPON THE TOTAL DRAINAGE AREA TO BE SERVED BY THE TRAP OR BASIN. a.THE MINIMUM STORAGE CAPACITY OF A SEDIMENT TRAP SHALL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA AND THE TRAP SHALL ONLY CONTROL DRAINAGE AREAS LESS THAN THREE ACRES. b.SURFACE RUNOFF FROM DISTURBED AREAS THAT IS COMPRISED OF FLOW FROM DRAINAGE AREAS GREATER THAN OR EQUAL TO THREE ACRES SHALL BE CONTROLLED BY A SEDIMENT BASIN. THE MINIMUM STORAGE CAPACITY OF A SEDIMENT BASIN SHALL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA. THE OUTFALL SYSTEM SHALL, AT A MINIMUM, MAINTAIN THE STRUCTURAL INTEGRITY OF THE BASIN DURING A 25-YEAR STORM OF 24-HOUR DURATION. RUNOFF COEFFICIENTS USED IN RUNOFF CALCULATIONS SHALL CORRESPOND TO A BARE EARTH CONDITION OR THOSE CONDITIONS EXPECTED TO EXIST WHILE THE SEDIMENT BASIN IS UTILIZED. 7.CUT AND FILL SLOPES SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT WILL MINIMIZE EROSION. SLOPES THAT ARE FOUND TO BE ERODING EXCESSIVELY WITHIN ONE YEAR OF PERMANENT STABILIZATION SHALL BE PROVIDED WITH ADDITIONAL SLOPE STABILIZING MEASURES UNTIL THE PROBLEM IS CORRECTED. 8.CONCENTRATED RUNOFF SHALL NOT FLOW DOWN CUT OR FILL SLOPES UNLESS CONTAINED WITHIN AN ADEQUATE TEMPORARY OR PERMANENT CHANNEL, FLUME OR SLOPE DRAIN STRUCTURE. 9.WHENEVER WATER SEEPS FROM A SLOPE FACE, ADEQUATE DRAINAGE OR OTHER PROTECTION SHALL BE PROVIDED. 10.ALL STORM SEWER INLETS THAT ARE MADE OPERABLE DURING CONSTRUCTION SHALL BE PROTECTED SO THAT SEDIMENT-LADEN WATER CANNOT ENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEING FILTERED OR OTHERWISE TREATED TO REMOVE SEDIMENT. 11.BEFORE NEWLY CONSTRUCTED STORMWATER CONVEYANCE CHANNELS OR PIPES ARE MADE OPERATIONAL, ADEQUATE OUTLET PROTECTION AND ANY REQUIRED TEMPORARY OR PERMANENT CHANNEL LINING SHALL BE INSTALLED IN BOTH THE CONVEYANCE CHANNEL AND RECEIVING CHANNEL. 12.WHEN WORK IN A LIVE WATERCOURSE IS PERFORMED, PRECAUTIONS SHALL BE TAKEN TO MINIMIZE ENCROACHMENT, CONTROL SEDIMENT TRANSPORT AND STABILIZE THE WORK AREA TO THE GREATEST EXTENT POSSIBLE DURING CONSTRUCTION. NONERODIBLE MATERIAL SHALL BE USED FOR THE CONSTRUCTION OF CAUSEWAYS AND COFFERDAMS. EARTHEN FILL MAY BE USED FOR THESE STRUCTURES IF ARMORED BY NONERODIBLE COVER MATERIALS. 13.WHEN A LIVE WATERCOURSE MUST BE CROSSED BY CONSTRUCTION VEHICLES MORE THAN TWICE IN ANY SIX-MONTH PERIOD, A TEMPORARY VEHICULAR STREAM CROSSING CONSTRUCTED OF NONERODIBLE MATERIAL SHALL BE PROVIDED. 14.ALL APPLICABLE FEDERAL, STATE AND LOCAL REQUIREMENTS PERTAINING TO WORKING IN OR CROSSING LIVE WATERCOURSES SHALL BE MET. 15.THE BED AND BANKS OF A WATERCOURSE SHALL BE STABILIZED IMMEDIATELY AFTER WORK IN THE WATERCOURSE IS COMPLETED. 16.UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TO OTHER APPLICABLE CRITERIA: a.NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME. b.EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES. c.EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVED SEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER THAT DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFF-SITE PROPERTY. d.MATERIAL USED FOR BACKFILLING TRENCHES SHALL BE PROPERLY COMPACTED IN ORDER TO MINIMIZE EROSION AND PROMOTE STABILIZATION. e.RESTABILIZATION SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THIS CHAPTER. f.APPLICABLE SAFETY REQUIREMENTS SHALL BE COMPLIED WITH. 17.WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED OR PUBLIC ROADS, PROVISIONS SHALL BE MADE TO MINIMIZE THE TRANSPORT OF SEDIMENT BY VEHICULAR TRACKING ONTO THE PAVED SURFACE. WHERE SEDIMENT IS TRANSPORTED ONTO A PAVED OR PUBLIC ROAD SURFACE, THE ROAD SURFACE SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM THE ROADS BY SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. THIS PROVISION SHALL APPLY TO INDIVIDUAL DEVELOPMENT LOTS AS WELL AS TO LARGER LAND-DISTURBING ACTIVITIES. 18.ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, UNLESS OTHERWISE AUTHORIZED BY THE VESCP AUTHORITY. TRAPPED SEDIMENT AND THE DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES SHALL BE PERMANENTLY STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION. 19.PROPERTIES AND WATERWAYS DOWNSTREAM FROM DEVELOPMENT SITES SHALL BE PROTECTED FROM SEDIMENT DEPOSITION, EROSION AND DAMAGE DUE TO INCREASES IN VOLUME, VELOCITY AND PEAK FLOW RATE OF STORMWATER RUNOFF FOR THE STATED FREQUENCY STORM OF 24-HOUR DURATION IN ACCORDANCE WITH THE FOLLOWING STANDARDS AND CRITERIA. STREAM RESTORATION AND RELOCATION PROJECTS THAT INCORPORATE NATURAL CHANNEL DESIGN CONCEPTS ARE NOT MAN-MADE CHANNELS AND SHALL BE EXEMPT FROM ANY FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MAN-MADE CHANNELS: a.CONCENTRATED STORMWATER RUNOFF LEAVING A DEVELOPMENT SITE SHALL BE DISCHARGED DIRECTLY INTO AN ADEQUATE NATURAL OR MAN-MADE RECEIVING CHANNEL, PIPE OR STORM SEWER SYSTEM. FOR THOSE SITES WHERE RUNOFF IS DISCHARGED INTO A PIPE OR PIPE SYSTEM, DOWNSTREAM STABILITY ANALYSES AT THE OUTFALL OF THE PIPE OR PIPE SYSTEM SHALL BE PERFORMED. b.ADEQUACY OF ALL CHANNELS AND PIPES SHALL BE VERIFIED IN THE FOLLOWING MANNER: (1)THE APPLICANT SHALL DEMONSTRATE THAT THE TOTAL DRAINAGE AREA TO THE POINT OF ANALYSIS WITHIN THE CHANNEL IS 100 TIMES GREATER THAN THE CONTRIBUTING DRAINAGE AREA OF THE PROJECT IN QUESTION; (2)(A) NATURAL CHANNELS SHALL BE ANALYZED BY THE USE OF A TWO-YEAR STORM TO VERIFY THAT STORMWATER WILL NOT OVERTOP CHANNEL BANKS NOR CAUSE EROSION OF CHANNEL BED OR BANKS. (b)ALL PREVIOUSLY CONSTRUCTED MAN-MADE CHANNELS SHALL BE ANALYZED BY THE USE OF A 10-YEAR STORM TO VERIFY THAT STORMWATER WILL NOT OVERTOP ITS BANKS AND BY THE USE OF A TWO-YEAR STORM TO DEMONSTRATE THAT STORMWATER WILL NOT CAUSE EROSION OF CHANNEL BED OR BANKS; AND (c)PIPES AND STORM SEWER SYSTEMS SHALL BE ANALYZED BY THE USE OF A 10-YEAR STORM TO VERIFY THAT STORMWATER WILL BE CONTAINED WITHIN THE PIPE OR SYSTEM. c.IF EXISTING NATURAL RECEIVING CHANNELS OR PREVIOUSLY CONSTRUCTED MAN-MADE CHANNELS OR PIPES ARE NOT ADEQUATE, THE APPLICANT SHALL: (1)IMPROVE THE CHANNELS TO A CONDITION WHERE A 10-YEAR STORM WILL NOT OVERTOP THE BANKS AND A TWO-YEAR STORM WILL NOT CAUSE EROSION TO THE CHANNEL, THE BED, OR THE BANKS. (2)IMPROVE THE PIPE OR PIPE SYSTEM TO A CONDITION WHERE THE 10-YEAR STORM IS CONTAINED WITHIN THE APPURTENANCES; (3)DEVELOP A SITE DESIGN THAT WILL NOT CAUSE THE PRE-DEVELOPMENT PEAK RUNOFF RATE FROM A TWO YEAR STORM TO INCREASE WHEN RUNOFF OUTFALLS INTO A NATURAL CHANNEL OR WILL NOT CAUSE THE PRE-DEVELOPMENT PEAK RUNOFF RATE FROM A 10-YEAR STORM TO INCREASE WHEN RUNOFF OUTFALLS INTO A MAN-MADE CHANNEL; OR (4)PROVIDE A COMBINATION OF CHANNEL IMPROVEMENT, STORMWATER DETENTION OR OTHER MEASURES WHICH IS SATISFACTORY TO THE VESCP AUTHORITY TO PREVENT DOWNSTREAM EROSION d.THE APPLICANT SHALL PROVIDE EVIDENCE OF PERMISSION TO MAKE THE IMPROVEMENTS. e.ALL HYDROLOGIC ANALYSES SHALL BE BASED ON THE EXISTING WATERSHED CHARACTERISTICS AND THE ULTIMATE DEVELOPMENT CONDITION OF THE SUBJECT PROJECT. f.IF THE APPLICANT CHOOSES AN OPTION THAT INCLUDES STORMWATER DETENTION, HE SHALL OBTAIN APPROVAL FROM THE VESCP OF A PLAN FOR MAINTENANCE OF THE DETENTION FACILITIES. THE PLAN SHALL SET FORTH THE MAINTENANCE REQUIREMENTS OF THE FACILITY AND THE PERSON RESPONSIBLE FOR PERFORMING THE MAINTENANCE. g.OUTFALL FROM A DETENTION FACILITY SHALL BE DISCHARGED TO A RECEIVING CHANNEL, AND ENERGY DISSIPATERS SHALL BE PLACED AT THE OUTFALL OF ALL DETENTION FACILITIES AS NECESSARY TO PROVIDE A STABILIZED TRANSITION FROM THE FACILITY TO THE RECEIVING CHANNEL. h.ALL ON-SITE CHANNELS MUST BE VERIFIED TO BE ADEQUATE. i.INCREASED VOLUMES OF SHEET FLOWS THAT MAY CAUSE EROSION OR SEDIMENTATION ON ADJACENT PROPERTY SHALL BE DIVERTED TO A STABLE OUTLET, ADEQUATE CHANNEL, PIPE OR PIPE SYSTEM, OR TO A DETENTION FACILITY. j.IN APPLYING THESE STORMWATER MANAGEMENT CRITERIA, INDIVIDUAL LOTS OR PARCELS IN A RESIDENTIAL, COMMERCIAL OR INDUSTRIAL DEVELOPMENT SHALL NOT BE CONSIDERED TO BE SEPARATE DEVELOPMENT PROJECTS. INSTEAD, THE DEVELOPMENT, AS A WHOLE, SHALL BE CONSIDERED TO BE A SINGLE DEVELOPMENT PROJECT. HYDROLOGIC PARAMETERS THAT REFLECT THE ULTIMATE DEVELOPMENT CONDITION SHALL BE USED IN ALL ENGINEERING CALCULATIONS. k.ALL MEASURES USED TO PROTECT PROPERTIES AND WATERWAYS SHALL BE EMPLOYED IN A MANNER WHICH MINIMIZES IMPACTS ON THE PHYSICAL, CHEMICAL AND BIOLOGICAL INTEGRITY OF RIVERS, STREAMS AND OTHER WATERS OF THE STATE. l.ANY PLAN APPROVED PRIOR TO JULY 1, 2014, THAT PROVIDES FOR STORMWATER MANAGEMENT THAT ADDRESSES ANY FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MAN-MADE CHANNELS SHALL SATISFY THE FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MAN-MADE CHANNELS IF THE PRACTICES ARE DESIGNED TO (I) DETAIN THE WATER QUALITY VOLUME AND TO RELEASE IT OVER 48 HOURS; (II) DETAIN AND RELEASE OVER A 24-HOUR PERIOD THE EXPECTED RAINFALL RESULTING FROM THE ONE YEAR, 24-HOUR STORM; AND (III) REDUCE THE ALLOWABLE PEAK FLOW RATE RESULTING FROM THE 1.5, 2, AND 10-YEAR, 24-HOUR STORMS TO A LEVEL THAT IS LESS THAN OR EQUAL TO THE PEAK FLOW RATE FROM THE SITE ASSUMING IT WAS IN A GOOD FORESTED CONDITION, ACHIEVED THROUGH MULTIPLICATION OF THE FORESTED PEAK FLOW RATE BY A REDUCTION FACTOR THAT IS EQUAL TO THE RUNOFF VOLUME FROM THE SITE WHEN IT WAS IN A GOOD FORESTED CONDITION DIVIDED BY THE RUNOFF VOLUME FROM THE SITE IN ITS PROPOSED CONDITION, AND SHALL BE EXEMPT FROM ANY FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MAN-MADE CHANNELS AS DEFINED IN ANY REGULATIONS PROMULGATED PURSUANT TO § 62.1-44.15:54 OR 62.1-44.15:65 OF THE ACT. m.FOR PLANS APPROVED ON AND AFTER JULY 1, 2014, THE FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS OF § 62.1-44.15:52 A OF THE ACT AND THIS SUBSECTION SHALL BE SATISFIED BY COMPLIANCE WITH WATER QUANTITY REQUIREMENTS IN THE STORMWATER MANAGEMENT ACT (§ 62.1-44.15:24 ET SEQ. OF THE CODE OF VIRGINIA) AND ATTENDANT REGULATIONS, UNLESS SUCH LAND-DISTURBING ACTIVITIES (I) ARE IN ACCORDANCE WITH PROVISIONS FOR TIME LIMITS ON APPLICABILITY OF APPROVED DESIGN CRITERIA IN 9VAC25-870-47 OR GRANDFATHERING IN 9VAC25-870-48 OF THE VIRGINIA STORMWATER MANAGEMENT PROGRAM (VSMP) REGULATION, IN WHICH CASE THE FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS OF § 62.1-44.15:52 A OF THE ACT SHALL APPLY, OR (II) ARE EXEMPT PURSUANT TO § 62.1-44.15:34 C 7 OF THE ACT. n.COMPLIANCE WITH THE WATER QUANTITY MINIMUM STANDARDS SET OUT IN 9VAC25-870-66 OF THE VIRGINIA STORMWATER MANAGEMENT PROGRAM (VSMP) REGULATION SHALL BE DEEMED TO SATISFY THE REQUIREMENTS OF THIS SUBDIVISION 19. 20. MAINTAIN A MINIMUM OF 12' FROST DEPTH AT THE EXISTING FOOTINGS. LONG TERM MAINTENANCE AND REPAIR PLAN MOWING: ALL GRASSES SHOULD BE MOWED AT LEAST TWICE EACH YEAR. GRASSES SUCH AS TALL FESCUE SHOULD BE MOWED IN EARLY SUMMER AFTER EMERGENCE OF THE HEADS ON COOL SEASON GRASSES. THEY SHOULD BE MOWED AGAIN IN THE EARLY FALL TO PREVENT SEEDS OF ANNUAL WEEDS FROM MATURING. MOWING OF LEGUMES SUCH AS SERICEA LESPEDEZA AND CROWN VETCH CAN BE PERMITTED TO GROW ON THE DAM OR IN ANY PART OF THE EMERGENCY SPILLWAY. LIMING AND FERTILIZING: THE SOIL SHOULD BE SAMPLED ACCORDING TO RECOMMENDED PROCEDURES AT LEAST ONCE EVERY 4 YEARS. THE SAMPLE SHOULD BE TESTED AT A QUALIFIED SOIL TESTING LABORATORY (SUCH AS THE ONE AT VPI&SU). LIME AND FERTILIZER SHOULD BE APPLIED IN ACCORDANCE WITH RECOMMENDATIONS BASED ON THE TESTS. REPLANTING AND OVER SEEDING: IF VEGETATION COVERS LESS THAN 40% OF THE SOIL SURFACE, LIME, FERTILIZE AND SEED IN ACCORDANCE WITH CURRENT RECOMMENDATIONS FOR NEW SEEDING. IF VEGETATION COVERS MORE THAN 40% BUT LESS THAN 70% OF THE SOIL SURFACE, LIME FERTILIZE AND OVER SEED IN ACCORDANCE WITH CURRENT RECOMMENDATIONS. REMOVING TRASH AND DEBRIS: TRASH, LITTER AND VEGETATION (OTHER THAN GRASS) WILL BE REMOVED AS NEEDED (BUT NO LESS THAN TWO TIMES PER YEAR) TO PREVENT OBSTRUCTION TO THE FLOW OF WATER, TO PREVENT MOVEMENT OF TRASH AND LITTER TO DOWNSTREAM PROPERTIES, TO MAINTAIN THE INTEGRITY OF THE STRUCTURE, TO PROVIDE AN ATTRACTIVE APPEARANCE AND TO MINIMIZE WATER POLLUTION. REMOVING SEDIMENT: SOIL MATERIALS (INCLUDING CLAY, SILT, SAND AND GRAVEL) WILL BE REMOVED BEFORE THE DETENTION POOL LOSES 10% OF THE DESIGNED STORAGE CAPACITY. SEDIMENT DISPOSAL: SEDIMENT DISPOSAL SHOULD BE IN ACCORDANCE WITH CURRENT PROCEDURES FOR DISPOSAL OF SEDIMENT. WHERE REQUIRED BY THE APPROPRIATE AUTHORITIES, THE SEDIMENT WILL BE TESTED FOR APPROPRIATE POLLUTANTS AT THE OWNER'S EXPENSE BEFORE IT IS REMOVED FROM THE POND. REPAIRS: REPAIR SLIDES, SLUMPS AND ERODED AREAS PROMPTLY AND IN A WORKMANLIKE MANNER TRASH RACKS, PIPES, HEADWALLS, ETC. WILL BE MAINTAINED, REPAIRED AND/OR REPLACED AS NEEDED TO MAINTAIN THE INTEGRITY OF THE STRUCTURE. EXPOSED METAL SURFACES WILL BE PAINTED TO MINIMIZE DAMAGE DUE TO RUST. MAINTENANCE INSPECTIONS: THE OWNER WILL BE RESPONSIBLE FOR INSPECTING EACH STORMWATER MANAGEMENT STRUCTURE AFTER EACH SIGNIFICANT RAINFALL. ONCE EACH YEAR A REPRESENTATIVE OF DEQ WILL JOINTLY INSPECT EACH STORMWATER MANAGEMENT STRUCTURE. APPROPRIATE ACTION WILL BE TAKEN TO ENSURE APPROPRIATE MAINTENANCE. ALL MAINTENANCE COSTS WILL BE BORNE BY THE OWNER. WHERE STRUCTURES ARE TO BE MAINTAINED BY MORE THAN ONE PARTY, ALLOCATION OF COSTS WILL BE IN ACCORDANCE WITH TERMS SET FORTH IN THE MAINTENANCE AGREEMENT. KEYS TO LOCKED ACCESS POINTS SHALL BE AVAILABLE TO DEQ PERSONNEL UPON REQUEST. MAINTENANCE RECORDS: THE LANDOWNER, OR SOMEONE DESIGNATED BY THE LANDOWNER, SHALL INSPECT THE DETENTION POND WITHIN 24 HOURS AFTER EACH RAINFALL EVENT OF ONE INCH OR MORE OF RAIN. THE OWNER OR THE DESIGNEE SHALL KEEP WRITTEN RECORDS OF THESE INSPECTIONS. THE RECORDS SHALL ALSO INCLUDE MAINTENANCE AND REPAIRS PERFORMED. COPIES OF THESE RECORDS SHALL BE PROVIDED TO THE COUNTY UPON REQUEST. THE WATER QUALITY FEATURES SHALL NOT BE MODIFIED IN ANY WAY WITHOUT PRIOR APPROVAL BY DEQ AND FREDERICK COUNTY. ·TOPSOIL SHALL BE SPREAD AT A MINIMUM DEPTH OF 4". ·PULVERIZED AGRICULTURAL LIMESTONE SHALL BE INCORPORATED INTO SOIL AT A RATE OF 92 LBS. PER 1000 S.F. (2 TONS PER ACRE). ·FERTILIZE WITH 10-20-10 AT A RATE OF 12 LBS. PER 1000 S.F. (500 LBS. PER ACRE). SEED MIX SHALL CONSIST OF 90% KENTUCKY 31 TALL FESUE AND 10% KENTUCKY BLUEGRASS APPLIED AT THE RATE OF 200 LBS. PER ACRE. EROSION AND SEDIMENT CONTROL NARRATIVE PROJECT DESCRIPTION THIS IS AN EXISTING ELEMENTARY SCHOOL BUILDING LOCATED AT 1548 HAYFIELD ROAD. THE PARCEL IS 19.5064 ACRES OF WHICH WE ARE DISTURBING 3.95 ACRES. IMPROVEMENTS TO THE SITE WILL INCLUDE REVISED GRADING, INSTALLATION OF ADDITIONAL STORM STRUCTURES AND PIPES, A NEW CONCRETE SIDEWALK, TWO NEW MOBILE CLASSROOM BUILDINGS, AND AN EMERGENCY ACCESS ROAD. EXISTING SITE CONDITIONS THE SITE IS CURRENTLY USED AS AN ELEMENTARY SCHOOL AND ITS SLOPES RANGE FROM 1.00% TO 50% AND IS A MIX OF BUILDINGS, ASPHALT AND MANAGED TURF. ADJACENT PROPERTY THE PROJECT IS BORDERED BY AGRICULTURAL LAND TO THE SOUTH AND WEST, INDIAN HOLLOW ROAD TO THE NORTH, AND NORTH HAYFIELD ROAD & RESIDENTIAL PROPERTY TO THE EAST. OFF-SITE AREAS NO OFF-SITE AREAS ARE ASSOCIATED WITH THIS PROJECT. SOILS AND GEOLOGY SEE SHEET CS1000 FOR SOILS INFORMATION. CRITICAL AREAS CRITICAL AREAS, CONSIST OF 2.5 OR 3:1 SLOPES. THESE SLOPES HAVE THE POTENTIAL FOR GREATER EROSION AND SHALL BE IMMEDIATELY STABILIZED AFTER REACHING FINAL GRADE. EROSION AND SEDIMENT CONTROL MEASURES UNLESS OTHERWISE INDICATED, ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CONSTRUCTED AND MAINTAINED ACCORDING TO THE MINIMUM STANDARDS AND SPECIFICATIONS OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK. STRUCTURAL MEASURES THE CONSTRUCTION ENTRANCE AND SILT FENCES SHOWN ON THE PLANS SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND-DISTURBING ACTIVITY AND SHALL BE MADE FUNCTIONAL BEFORE UP-SLOPE LAND DISTURBANCE TAKES PLACE. PHASE I: CONSTRUCTION ENTRANCE WITH WASH RACK (3.02) SHALL BE INSTALLED AT THE LOCATION SHOWN ON THE EROSION AND SEDIMENT CONTROL PLAN TO PREVENT MUD AND DEBRIS FROM BEING TRACKED ONTO ROADWAYS. SILT FENCE WITH WIRE SUPPORT (3.05) SHALL BE INSTALLED AS SHOWN ON THE PLANS TO FILTER RUNOFF FROM DISTURBED AREAS BEFORE IT LEAVES THE SITE. INSTALL SEDIMENT TRAP PER EROSION PHASE I PLAN. CULVERT INLET PROTECTION (3.08) SHALL BE INSTALLED AS SHOWN ON PLANS TO FILTER RUNOFF BEFORE IT LEAVES THE SITE. OUTLET PROTECTION (3.18) SHALL BE INSTALLED AT OUTLET STRUCTURES TO MINIMIZE POTENTIAL FOR DOWNSTREAM EROSION BY REDUCING THE VELOCITY AND ENERGY ON CONCENTRATED STORMWATER FLOWS. TEMPORARY SEEDING (3.31) AND/OR PERMANENT SEEDING (3.32) SHALL BE PLACED ON ALL CRITICAL SLOPES (3:1 OR GREATER) AND AS NEEDED TO STABILIZE DISTURBED AREAS. PHASE II: ALL CONTROLS INSTALLED IN PHASE I SHOULD REMAIN UNTIL THE SITE IS STABILIZED. ROCK CHECK DAMS (3.20) SHALL BE INSTALLED TO SLOW DOWN RUNOFF AND REMOVE SEDIMENT ALONG THE SWALE. SOIL STABILIZATION MATTING (3.36) SHALL BE INSTALLED ON DISTURBED SLOPES STEEPER THAN 3:1. VEGETATIVE MEASURES PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN (7) DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN SEVEN (7) DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN DORMANT FOR LONGER THAN FOURTEEN (14) DAYS. PERMANENT SOIL STABILIZATION SHALL BE APPLIED TO ALL AREAS THAT ARE TO BE LEFT DORMANT FOR MORE THAN SIX (6) MONTHS. SOIL THAT HAS BEEN STOCKPILED SHALL BE SURROUNDED WITH SILT FENCE AND PROTECTED BY MULCH AND/OR TEMPORARY VEGETATION IMMEDIATELY AFTER GRADING. ALL EARTH BERMS, DAMS, DIKES, DIVERSIONS AND SEDIMENT TRAP EMBANKMENTS ARE TO BE MACHINE-COMPACTED, IMMEDIATELY SEEDED AND MULCHED (HAY MULCH OR STRAW) FOR TEMPORARY AND/OR PERMANENT VEGETATIVE COVER WITHIN FIVE (5) DAYS AFTER GRADING. VEGETATIVE STABILIZATION SHALL BE UNIFORM, MATURE ENOUGH TO SURVIVE AND ADEQUATE TO INHIBIT EROSION. MANAGEMENT STRATEGIES CONSTRUCTION SHALL BE SEQUENCED SUCH THAT GRADING OPERATIONS WILL BEGIN AND END AS QUICKLY AS POSSIBLE. THE SITE SUPERINTENDENT SHALL BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL EROSION AND SEDIMENT CONTROL MEASURES. MAINTENANCE OF THESE MEASURES THROUGHOUT THE PROJECT ARE CRITICAL TO THE EFFECTIVENESS OF THE PROGRAM. AFTER AREAS ABOVE CONTROLS HAVE BEEN STABILIZED, THE CONTROLS SHALL BE CLEANED UP AND REMOVED AT THE DIRECTION OF THE FREDERICK COUNTY INSPECTOR. ALL CUT AND FILL SLOPES ARE TO BE SEEDED AND MULCHED WITHIN FIVE (5) DAYS OF COMPLETION OF GRADING. CUT AND FILL SLOPES SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT WILL MINIMIZE EROSION. SLOPES THAT ARE FOUND TO BE ERODING EXCESSIVELY WITHIN ONE YEAR OF PERMANENT STABILIZATION SHALL BE PROVIDED WITH ADDITIONAL SLOPE STABILIZING MEASURES UNTIL THE PROBLEM IS CORRECTED. DRAINAGE SWALES SHALL BE STABILIZED WITH CHECK DAMS UNTIL VEGETATION HAS BEEN WELL ESTABLISHED, AT WHICH TIME THE CHECK DAMS SHALL BE REMOVED. CONCENTRATED RUNOFF SHALL NOT FLOW DOWN CUT OR FILL SLOPES UNLESS CONTAINED WITHIN AN ADEQUATE TEMPORARY OR PERMANENT CHANNEL, FLUME, OR SLOPE DRAIN STRUCTURE. WHENEVER WATER SEEPS FROM A SLOPE FACE, ADEQUATE DRAINAGE OR OTHER PROTECTION SHALL BE PROVIDED. ALL STORM SEWER INLETS THAT ARE MADE OPERABLE DURING CONSTRUCTION SHALL BE PROTECTED SO THAT SEDIMENT-LADEN WATER CANNOT ENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEING FILTERED OR OTHERWISE TREATED TO REMOVE SEDIMENT. WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED OR PUBLIC ROADS, PROVISIONS SHALL BE MADE TO MINIMIZE THE TRANSPORT OF SEDIMENT BY VEHICULAR TRACKING ONTO THE PAVED SURFACE. WHERE SEDIMENT IS TRANSPORTED ONTO A PAVED OR PUBLIC ROAD SURFACE, THE ROAD SURFACE SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM THE ROADS BY SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, UNLESS OTHERWISE AUTHORIZED BY THE LOCAL PROGRAM AUTHORITY. TRAPPED SEDIMENT AND THE DISTURBED SOILS AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES SHALL BE PERMANENTLY STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION. DEVICES LISTED ABOVE ARE CONSIDERED MINIMUM EROSION AND SEDIMENT CONTROLS. ADDITIONAL CONTROL MEASURES MAY BE NECESSARY DUE TO CONTRACTOR PHASING OR OTHER UNFORESEEN CONDITIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADDITIONAL MEASURES TO THOSE SHOWN, AS NEEDED, IN ORDER TO CONTROL EROSION AND CONTAIN SEDIMENT ON SITE. ALL MEASURES SHALL BE INSTALLED ACCORDING TO THE STANDARDS AND SPECIFICATIONS IN THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK.(VESCH) ANY CHANGES MADE TO THIS PLAN MUST BE RESUBMITTED FOR APPROVAL WITHOUT EXCEPTION. MAINTENANCE ALL CONTROL MEASURES SHALL BE INSPECTED DAILY BY THE SITE SUPERINTENDENT OR HIS REPRESENTATIVE AND WITHIN 24 HOURS AFTER ANY STORM EVENT GREATER THAN 0.5 INCHES OF RAIN PER 24 HOUR PERIOD. ANY DAMAGED STRUCTURAL MEASURES ARE TO BE REPAIRED BY THE END OF THE DAY. SEEDED AREAS SHALL BE CHECKED REGULARLY TO ENSURE THAT A GOOD STAND OF GRASS IS MAINTAINED. ALL AREAS SHALL BE FERTILIZED AND RESEEDED AS NEEDED UNTIL GRASS IS ESTABLISHED. FILL SLOPES GREATER THAN 3:1 WILL REQUIRE A SLOPE STABILITY ANALYSIS & MAINTENANCE PLAN. TRAPPED SEDIMENT IS TO BE REMOVED AS REQUIRED TO MAINTAIN 50% TRAP EFFICIENCY AND DISPOSED OF BY SPREADING ON SITE. GRAVEL OUTLETS SHALL BE CHECKED REGULARLY FOR SEDIMENT BUILD-UP. IF THE GRAVEL OUTLET IS CLOGGED BY SEDIMENT, IT SHALL BE REMOVED AND CLEANED OR REPLACED IMMEDIATELY. THE CONTRACTOR IS RESPONSIBLE FOR KEEPING EXISTING PUBLIC ROADS IN A CLEAN, DUST AND MUD FREE, CONDITION AT ALL TIMES. PERMANENT STABILIZATION ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE STABILIZED WITH PERMANENT SEEDING IMMEDIATELY FOLLOWING FINAL GRADING. SEEDING SHALL BE DONE ACCORDING TO STANDARD AND SPECIFICATION NO. 3.32 OF THE VESCH. PERMANENT STABILIZATION IS DEFINED AS 90% UNIFORM COVERAGE ON THE ENTIRE SITE, ABILITY TO INHIBIT EROSION AND MATURE ENOUGH TO SURVIVE, INCLUDING 2-3 INCH CUTTINGS. PHASES OF LAND DISTURBANCE ACTIVITIES 1.MANDATORY PRE-CONSTRUCTION CONFERENCE SHALL BE SCHEDULED AS REQUIRED BY REGULATIONS. 2.CLEARING AND GRUBBING FOR SEDIMENT CONTROL DEVICES ONLY. 3.INSTALLATION OF ALL PHASE I EROSION & SEDIMENT CONTROL DEVICES. 4.OBTAIN COUNTY INSPECTOR APPROVAL. 5.ROUGH GRADE SITE AND CONSTRUCT FACILITIES. 6.RESTORATION AND STABILIZATION OF DISTURBED AREAS. 7.REMOVE ALL EROSION & SEDIMENT CONTROL MEASURES WITH THE APPROVAL OF THE INSPECTOR.U:\Accounts\RRMMX\RRMMX21005 - Indian Hollow ES Renovation\DESIGN\_SHEETS\02-Design Development\CS2000 ES NARRATIVE.dwg PLOTTED: 3/25/2022 1:37 PM, BY: Liliana Hernandez PLOTSTYLE: Pennoni NCS.stb PROJECT STATUS: CONSTRUCTION DRAWINGSBYNO.DATEREVISIONSRRMMX21005 AS NOTED CJM 2021-11-18 RAMAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493100% CD PLAN SET 01/31/2022  03/25/2022 FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VA. 22604EROSION AND SEDIMENT CONTROL NARRATIVECS2000 TOTAL SHEETS 17INDIAN HOLLOW ELEMENTARY SCHOOLMINOR RENOVATIONS AND REPAIRSCONSTRUCTION DRAWINGS1548 NORTH HAYFIELD RD. | WINCHESTER, VA. 22603GAINESBORO MAGISTERIAL DISTRICTDAVID L. FRANK Lic. No.1061 78618 EX780795790785 77577 5 78 0 7817 8 1 780779 794793792791789788787786 801 780 7857907958007 7 8 77877977 9 781782783 784 786 787788789791792793794796797798799 7 8 0 780784780770775775 7697717727 7 3 774774 776 776 777 777778 778779779784 775770765761762775 7 7 2771772773774775776 780 779779784783 785785784782780785790 782 783784782 7 8 4 7817 8 0 785780785 7 7 9 7 7 8778 7 7 7 7 76 7 7 7 774 772 773 771 770 7 7 7 2 0 H P OVERLANDRELIEF78382EX78188EX78097EX INV. (761.97)INV. (762.31)12" PVC INV. (766.82) 1 2 " P V C I N V . ( 7 6 7 . 5 8 ) C O M BGRATE (779.00)IN (767.00)OUT (766.80)GRATE (7 8 3 . 3 7 ) OUT (782 . 4 7 ) (4)4" PEP P I P E S (DIR. UN K . ) R I M ( 7 7 9 . 6 8 ) IN ( 7 7 2 . 0 8 ) O U T ( 7 7 1 . 9 8 ) R I M ( 7 7 6 . 5 2 ) IN ( 7 7 0 . 2 2 ) O U T ( 7 7 0 . 0 2 ) ASPHALT CONC. WALKC O N C . W A L K A S P H A L T A S P H A L T CONC. WALKCONC. WALK CONC. WALKA S P H A L T M E T A L G U A R D R A I L ASPHALT ASPHALTP L A Y G R O U N D P L A Y G R O U N DPLAYGROUNDPLAYG R O U N D P L A Y G R O U N D PLAYGROUNDPLAYGROUNDPLAYGROUNDP L A Y G R O U N D A S P H A L T T R A C K P L A Y G R O U N D CONC. WALK C O N C R E T E ASPHALTC O N C . W A L K CONC. G R A S S G R A S S G R A S S G R A S S G R A S S GRASSGRASSGRASS G R A S S METAL RAMP CONC. WALKEX. MOBILECLASSROOM 4(910 SF)EX. MOBILECLASSROOM 1(910 SF)EX. MOBILECLASSROOM 2(952 SF)EX. MOBILECLASSROOM 3(952 SF)CONC.30" RCP30" RCP 30" R C P 6 " P V C A/CA/C CONCRETEGENERAT O R BUILDINGFUELTANK F . F . E . ( 7 8 0 . 4 9 ) F . F . E . ( 7 8 0 . 4 7 ) F . F . E . ( 7 8 0 . 4 9 ) F.F.E. (78 0 . 5 1 ) MP MP WP C O M P WPWP WP C O C O C O C O GRATE (7 7 8 . 6 8 ) OUT (76 9 . 3 8 ) GR A T E ( 7 7 7 . 2 8 ) IN ( 7 6 8 . 2 8 ) OU T ( 7 6 8 . 0 8 ) PI N 4 0 - A - 3 1 A C O U N T Y S C H O O L B O A R D O F F R E D E R I C K C O U N T Y VI R G I N I A D B 6 0 5 P G 7 8 5 ZO N E D : R A U S E : S C H O O L B R I C K S C H O O L B U I L D I N G "I N D I A N H O L L O W E L E M E N T A R Y S C H O O L " (5 9 , 8 9 0 S F )OVERHANGA / C CO N C . LO A D I N G RA M P FUELSTORA G EU/G O I L T A N K (APP R O X . )IRT 9004N=7135016.160E=11543499.058ELEV.=767.55EX CTR L P A N E LEXISTING TREELINEA P P R O X . L O C A T I O N O F T I M E C A P S U L E A P P R O X . L O C A T I O N O F E X . L A N D M A R K T R E E S W H H ( A P P R O X . ) ASPHALTPARKING LOTEX. ADAACCESSIBLE ROUTEA S P H A L T P A R K I N G L O TWP w/ELEC.OUTLETVERIFY WATERLINELOCATION BEFOREINSTALLING SILT FENCECEIPIPIPSFSFSFSFSFSFDDDD5'X8' CLIRIPRIP 5'X8' CLIRIPRIPLEVEL SPREADER10'X65'CDCDCDCDCDCDCDCDCD783784ST786787DDDD778 65EX 778 79EX778997789977839778 997789977839779780781 7852:1EROSION AND SEDIMENTCONTROL LEGENDNO.TITLEKEYSYMBOLTEMPORARY STONECONSTRUCTION ENTRANCECESILT FENCESF3.31TEMPORARY SEEDINGTSTS3.18OUTLET PROTECTIONOP3.08CULVERT INLET PROTECTIONCIPLIMITS OF DISTRUBANCE3.023.053.07IPSTORM DRAIN INLET PROTECTION3.09DDDDTEMPORARYDIVERSION DIKE3.20CDROCK CHECK DAMS3.21LSLEVEL SPREADERU:\Accounts\RRMMX\RRMMX21005 - Indian Hollow ES Renovation\DESIGN\_SHEETS\02-Design Development\CS2100 ESI.dwg PLOTTED: 3/25/2022 1:38 PM, BY: Liliana Hernandez PLOTSTYLE: Pennoni NCS.stb PROJECT STATUS: CONSTRUCTION DRAWINGS BYNO.DATE REVISIONSRRMMX21005AS NOTEDCJM2021-11-18RAMAPPROVED BYDRAWN BYDRAWING SCALEDATEPROJECTALL DOCUMENTS PREPARED BY PENNONI ASSOCIATESARE INSTRUMENTS OF SERVICE IN RESPECT OF THEPROJECT. THEY ARE NOT INTENDED OR REPRESENTEDTO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ONTHE EXTENSIONS OF THE PROJECT OR ON ANY OTHERPROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATIONOR ADAPTATION BY PENNONI ASSOCIATES FOR THESPECIFIC PURPOSE INTENDED WILL BE AT OWNERSSOLE RISK AND WITHOUT LIABILITY OR LEGALEXPOSURE TO PENNONI ASSOCIATES; AND OWNERSHALL INDEMNIFY AND HOLD HARMLESS PENNONIASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES ANDEXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTOR AND OWNER MUST BE NOTIFIED OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK0030'60'GRAPHIC SCALE 1"=30'PENNONI ASSOCIATES INC. 117 East Piccadilly Street Winchester, VA 22601 T 540.667.2139 F 540.665.0493 NOR T H100% CD PLAN SET 01/31/2022  03/25/2022 FREDERICK COUNTY PUBLIC SCHOOLS PO BOX 3508 | WINCHESTER, VA. 22604 EROSION AND SEDIMENT CONTROL PLAN PHASE ICS2100TOTAL SHEETS17INDIAN HOLLOW ELEMENTARY SCHOOL MINOR RENOVATIONS AND REPAIRS CONSTRUCTION DRAWINGS 1548 NORTH HAYFIELD RD. | WINCHESTER, VA. 22603 GAINESBORO MAGISTERIAL DISTRICT DAVID L. FRANKLic. No.1061 78778618 EX799798797796795794793792791790789788786785786790782781780781782784785786779778779 7797 8 1 7 8 0 783784 783780780779777795790785 77577 5 78 0 7817 8 1 780779 794793792791789788787786 801 780 78579079580077877877977 9 781782783 784 786 787788789791792793794796797798799 7 8 0 780784780770775775 7697717727 7 3 774776 776 777 777778 778779779775770765762775 7 7 2771772773774775776 780 779779784783 785785784782780785790 782 783784782 7 8 4 7817 8 0 785780785 7 7 9 7 7 8778 7 7 7 7 76 7 7 7 774 772 773 771 770 7 7 7 2 0 H P 77678077978382EX78188EX78097EX INV. (762.31)12" PVC INV. (766.82) 1 2 " P V C I N V . ( 7 6 7 . 5 8 ) C O M BGRATE (779.00)IN (767.00)OUT (766.80)R I M ( 7 7 9 . 6 8 ) IN ( 7 7 2 . 0 8 ) O U T ( 7 7 1 . 9 8 ) R I M ( 7 7 6 . 5 2 ) IN ( 7 7 0 . 2 2 ) O U T ( 7 7 0 . 0 2 ) ASPHALT CONC. WALKC O N C . W A L K A S P H A L T A S P H A L T CONC. WALKCONC. WALK CONC. WALKASPHALT ASPHALTP L A Y G R O U N D P L A Y G R O U N DPLAYGROUNDPLAYG R O U N D P L A Y G R O U N D PL A Y G R O U N DPLAYGROUNDPLAYGROUNDP L A Y G R O U N D A S P H A L T T R A C K P L A Y G R O U N D CONC. WALK C O N C R E T E ASPHALTCONC. G R A S S G R A S S G R A S S G R A S S GRASSGRASSMETAL RAMP CONC. WALKEX. MOBILECLASSROOM 4(910 SF)EX. MOBILECLASSROOM 1(910 SF)EX. MOBILECLASSROOM 2(952 SF)EX. MOBILECLASSROOM 3(952 SF)CONC.30" RCP30" RCP 30" R C P 6 " P V C CONCRETE GENERAT O R BUILDING F . F . E . ( 7 8 0 . 4 9 ) F . F . E . ( 7 8 0 . 4 7 ) F . F . E . ( 7 8 0 . 4 9 ) F.F.E. (78 0 . 5 1 ) MP MP WP C O WPWP WP C O C O C O C O GRATE (7 7 8 . 6 8 ) OUT (76 9 . 3 8 ) GR A T E ( 7 7 7 . 2 8 ) IN ( 7 6 8 . 2 8 ) OU T ( 7 6 8 . 0 8 ) PI N 4 0 - A - 3 1 A C O U N T Y S C H O O L B O A R D O F F R E D E R I C K C O U N T Y VI R G I N I A D B 6 0 5 P G 7 8 5 ZO N E D : R A U S E : S C H O O L B R I C K S C H O O L B U I L D I N G "I N D I A N H O L L O W E L E M E N T A R Y S C H O O L " (5 9 , 8 9 0 S F )OVERHANGA / C CO N C . LO A D I N G RA M P FUELSTORA G E ELEV.=767.55EX CTR L P A N E LEXISTING TREELINEA P P R O X . L O C A T I O N O F T I M E C A P S U L E A P P R O X . L O C A T I O N O F E X . LA N D M A R K T R E E S W H H ( A P P R O X . ) ASPHALTPARKING LOTEX. ADAACCESSIBLE ROUTEWP w/ELEC.OUTLET11.1A11A10.1A10A6A6.1A5.3EX5.2EX 5EX5.1325.4RESTROOM 10'X18' VDOT CLI RIPRAP(428 SF)PR. MOBILECLASSROOM 6(793 SF)PR. MOBILECLASSROOM 5(793 SF)MOBILE CLASSROOMS &DECK LANDING TO MATCH EX.DECK LANDING FFE33'x14' DECKING WITH 42"RAILING AT LOCATIONS A, B, & CFINAL FLOOR OF RESTROOM& DECKING TO MATCH EX.DECKING ELEVATIONNEW STAIRS - NO. OF RISERS AS REQUIRED BYTHE BUILDING CODE TO MEET FINAL GRADE.MAX 7" RISERS, MIN 10" TREADS. GREATESTRISER HEIGHT AND TREAD DEPTH WITHIN ANYFLIGHT OF STAIRS NOT TO EXCEED THESMALLEST BY 38"21'x10' DECKING WITH 42"RAILING AT LOCATIONS D & ECEIPIPOPIPIPCIPCIPOPPSPSPSSFSFSFBMIPVERIFY WATERLINELOCATION BEFOREINSTALLING SILT FENCESFSFSFDDDD5'X8' CLIRIPRIP 5'X8' CLIRIPRIPLEVEL SPREADER10'X65'CDCDCDCDCDCDCDCDCD147 LF EC-3 LININGBMBMAACIPOP779 780 781 778 99778 79EX77865EX778997783977839778 99778992:1EROSION AND SEDIMENTCONTROL LEGENDNO.TITLEKEYSYMBOLTEMPORARY STONECONSTRUCTION ENTRANCECEB/MSILT FENCESF3.32PERMANENT SEEDINGPSPS3.18OUTLET PROTECTIONOP3.08CULVERT INLET PROTECTIONCIPLIMITS OF DISTRUBANCECRITICAL SLOPESSOILS3.023.053.36SOIL STABILIZATION BLANKETS & MATTING3.07IPSTORM DRAIN INLET PROTECTION3.09DDDDTEMPORARYDIVERSION DIKE3.20CDROCK CHECK DAMS3.21LSLEVEL SPREADERU:\Accounts\RRMMX\RRMMX21005 - Indian Hollow ES Renovation\DESIGN\_SHEETS\02-Design Development\CS2200 ESII.dwg PLOTTED: 3/25/2022 1:39 PM, BY: Liliana Hernandez PLOTSTYLE: Pennoni NCS.stb PROJECT STATUS: CONSTRUCTION DRAWINGS BYNO.DATE REVISIONSRRMMX21005AS NOTEDCJM2021-11-18RAMAPPROVED BYDRAWN BYDRAWING SCALEDATEPROJECTALL DOCUMENTS PREPARED BY PENNONI ASSOCIATESARE INSTRUMENTS OF SERVICE IN RESPECT OF THEPROJECT. THEY ARE NOT INTENDED OR REPRESENTEDTO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ONTHE EXTENSIONS OF THE PROJECT OR ON ANY OTHERPROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATIONOR ADAPTATION BY PENNONI ASSOCIATES FOR THESPECIFIC PURPOSE INTENDED WILL BE AT OWNERSSOLE RISK AND WITHOUT LIABILITY OR LEGALEXPOSURE TO PENNONI ASSOCIATES; AND OWNERSHALL INDEMNIFY AND HOLD HARMLESS PENNONIASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES ANDEXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTOR AND OWNER MUST BE NOTIFIED OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK0030'60'GRAPHIC SCALE 1"=30'PENNONI ASSOCIATES INC. 117 East Piccadilly Street Winchester, VA 22601 T 540.667.2139 F 540.665.0493 NOR T H100% CD PLAN SET 01/31/2022  03/25/2022 FREDERICK COUNTY PUBLIC SCHOOLS PO BOX 3508 | WINCHESTER, VA. 22604 EROSION AND SEDIMENT CONTROL PLANS PHASE IICS2200TOTAL SHEETS17INDIAN HOLLOW ELEMENTARY SCHOOL MINOR RENOVATIONS AND REPAIRS CONSTRUCTION DRAWINGS 1548 NORTH HAYFIELD RD. | WINCHESTER, VA. 22603 GAINESBORO MAGISTERIAL DISTRICT DAVID L. FRANKLic. No.1061 U:\Accounts\RRMMX\RRMMX21005 - Indian Hollow ES Renovation\DESIGN\_SHEETS\02-Design Development\CS2500 ES DETAILS.dwg PLOTTED: 3/25/2022 1:41 PM, BY: Liliana Hernandez PLOTSTYLE: Pennoni NCS.stb PROJECT STATUS: CONSTRUCTION DRAWINGSBYNO.DATEREVISIONSRRMMX21005 AS NOTED CJM 2021-11-18 RAMAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493100% CD PLAN SET 01/31/2022  03/25/2022 FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VA. 22604EROSION AND SEDIMENT CONTROL DETAILSCS2500 TOTAL SHEETS 17INDIAN HOLLOW ELEMENTARY SCHOOLMINOR RENOVATIONS AND REPAIRSCONSTRUCTION DRAWINGS1548 NORTH HAYFIELD RD. | WINCHESTER, VA. 22603GAINESBORO MAGISTERIAL DISTRICTDAVID L. FRANK Lic. No.1061 Version 1.9 March 1, 2011 Page 7 OF 20 Version 1.9 March 1, 2011 Version 1.9 March 1, 2011 Page 7 OF 20 Page 8 OF 20 TYPICAL PARABOLIC DIVERSION TYPICAL TRAPEZOIDAL DIVERSION TYPICAL VEE-SHAPED DIVERSION 0.3' FREE BOARD 0.3' FREE BOARD 10% SETTLEMENT Source: Va. DSWC DESIGN FLOW DEPTH DESIGN FLOW DEPTH 10% SETTLEMENT 10% SETTLEMENT 0.3' FREE BOARD DESIGN FLOW DEPTH Plate 3.12-1 U:\Accounts\RRMMX\RRMMX21005 - Indian Hollow ES Renovation\DESIGN\_SHEETS\02-Design Development\CS2501 ES DETAILS.dwg PLOTTED: 3/25/2022 1:41 PM, BY: Liliana Hernandez PLOTSTYLE: Pennoni NCS.stb PROJECT STATUS: CONSTRUCTION DRAWINGSBYNO.DATEREVISIONSRRMMX21005 AS NOTED CJM 2021-11-18 RAMAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493100% CD PLAN SET 01/31/2022  03/25/2022 FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VA. 22604EROSION AND SEDIMENT CONTROL DETAILSCS2501 TOTAL SHEETS 17INDIAN HOLLOW ELEMENTARY SCHOOLMINOR RENOVATIONS AND REPAIRSCONSTRUCTION DRAWINGS1548 NORTH HAYFIELD RD. | WINCHESTER, VA. 22603GAINESBORO MAGISTERIAL DISTRICTDAVID L. FRANK Lic. No.1061 INV. ( 7 6 0 . 0 1 ) 1 5 " R C P I N V . ( 7 6 1 . 9 7 ) INV. (76 2 . 3 1 )12" PVCINV. (766.82)12" PV C INV . ( 7 6 7 . 5 8 ) CO MB INV. (759.75)GRATE (7 7 9 . 0 0 ) IN (767.0 0 ) OUT (766. 8 0 ) GRATE ( 7 8 3 . 3 7 ) OUT (782 . 4 7 ) (4)4" P E P P I P E S (DIR. U N K . ) RIM (7 7 9 . 6 8 ) IN (77 2 . 0 8 ) OUT (771 . 9 8 ) RIM ( 7 7 6. 5 2)IN (77 0. 2 2) OUT ( 7 7 0. 0 2)ASPHALTCONC. W A L K CONC. W A L K ASPHA L T ASPHA L T C O N C . W A L K CONC. WALKC O N C . W A L K ASPHA L T P A R K I N G L O T ASPHALT ASPHALTA S P H A L T PLAY G R O U N D PLAY G R O U N D PLAYGROUN D PLAY G R O U N D PLAY G R O U N D PLAYGROUNDPLAYGRO U N D PLAYGROUND PLAYG R O U N D ASPHA L T T R A C K ASPHA L T T R A C K PLAYG R O U N DCONC. WALKCONCRE T E A S P H A L T CONC. WALK CONC. WALK CONC.GRAS S GRAS S GRAS S GRAS S GRAS S GRAS S GRAS S GRASS METAL R A M P C O N C . W A L K E X . M O B I L E C L A S S R O O M 4 (9 1 0 S F ) E X . M O B I L E C L A S S R O O M 1 (9 1 0 S F ) E X . M O B I L E C L A S S R O O M 2 (9 5 2 S F ) E X . M O B I L E C L A S S R O O M 3 (9 5 2 S F ) C O N C . 30" RCP 30" RCP30" RCP6" PV C CONC R E T E GENE R A T O R BUILD I N G F.F.E. ( 7 8 0 . 4 9 ) F.F.E. ( 7 8 0 . 4 7 ) F.F.E. ( 7 8 0 . 4 9 ) F.F.E. ( 7 8 0 . 5 1 ) MP MP WP CO WP WP WP CO CO CO CO GRATE (77 8 . 6 8 ) OUT (769 . 3 8 )GRATE (777.28)IN (768.28)OUT (768.08)PIN 40 - A - 3 1 A COUNTY S C H O O L B O A R D O F F R E D E R I C K C O U N T Y VIRGIN I A DB 605 P G 7 8 5 ZONED: R A U S E : S C H O O L BRICK S C H O O L B U I L D I N G "INDIA N H O L L O W E L E M E N T A R Y S C H O O L " (59,89 0 S F ) O V E R H A N G A/C CONC. LOADIN GRAMP FUEL STOR A G E EX CTR L P A N E L EXISTING TREELINE APPROX . L O C A T I O N OF TIME C A P S U L E APPRO X . LOCA T I O N OF EX. LAND M A R K TREES WHH (AP P R O X . ) ASPHAL T PARKIN G L O T EX. ADA ACCESSIBLE ROUTE ASPHAL T PARKIN G L O T WP w/ ELEC. OUTLET 24' 2 4 ' 24' 3 - SECURED BOLLARDS NOT REMOVABLE BY THE GENERAL PUBLIC EXISTING SIDEWALK TO BE REPLACED AFTER FINAL GRADING 3 - SECURED BOLLARDS NOT REMOVABLE BY THE GENERAL PUBLIC 24' EMERGENCYACCESS LANEEXISTING RETAINING WALL AND SIDEWALK TO REMAIN 24' 80'80'70' 70'24'150' 1 5 0 ' 150' RELOCATE EX. 4" CONDUIT TO 30" BELOW PROP. FINISHED GRADE CONTRACTOR TO UNCOVER AND VERIFY LOCATION OF UTILITIES. STR 5.3 CAN BE SHIFTED TO AVOID CONDUIT IF NECESSARY (SEE CS6100)RESTROOM 36.67'1 1 . 6 7 '23.33'3 4 ' 3 4 ' 24' E M E R G E N C Y ACCE S S L A N E 24' EMERGENCYACCESS LANEFIRE LANE STRIPINGMECHANICAL UNITS (SEE ARCHITECTURAL PLANS) MECHANICAL UNITS (SEE ARCHITECTURAL PLANS) 10'X18' VDOT CLI RIPRAP EXISTING SIDEWALK TO BE REPLACED AFTER FINAL GRADING EX. SIDEWALK TO BE REPLACED AFTER FINAL GRADING(428 SF)P R . M O B I L E C L A S S R O OM 6 ( 7 9 3 S F ) P R . M O B I L E C L A S S R O OM 5 ( 7 9 3 S F )ABC8'1 4 '33'MOBILE CLASSROOMS & DECK LANDING TO MATCH EX. DECK LANDING FFE 33'x14' DECKING WITH 42" RAILING AT LOCATIONS A, B, & C FINAL FLOOR OF RESTROOM & DECKING TO MATCH EX. DECKING ELEVATION NEW STAIRS - NO. OF RISERS AS REQUIRED BY THE BUILDING CODE TO MEET FINAL GRADE. MAX 7" RISERS, MIN 10" TREADS. GREATEST RISER HEIGHT AND TREAD DEPTH WITHIN ANY FLIGHT OF STAIRS NOT TO EXCEED THE SMALLEST BY 3 8" 21'x10' DECKING WITH 42" RAILING AT LOCATIONS D & E DE1 0 '21'23.33'2 - 1 5 " H D P E 11.1A 11A 10.1A 10A 6A 6.1A 5.3 EX 5.2 EX 5 EX 5.1 3 2 30" HD P E (4) 12" SDR-35 DEPRESSED FOR OVERFLOW OVERLAND DRAINAGE OPTION II (2) 12" SDR-35 DEPRESSED FOR OVERFLOW OVERLAND DRAINAGE OPTION I 9 LF 4" PVC SCH-40 UNDEDRAIN @ 1.00% MIN 75 LF 4" PVC SCH-40 UNDERDRAIN @ 1.00% M I N WITH SCREEN 77 L F 4 " P V C S C H - 4 0 UN D E R D R A I N @ 1 . 0 0 % M I N WI T H S C R E E N 58 LF 4" P V C S C H - 4 0 UNDERD R A I N @ 1 . 0 0 % M I N WITH SC R E E N 5.418" HDPEU:\Accounts\RRMMX\RRMMX21005 - Indian Hollow ES Renovation\DESIGN\_SHEETS\02-Design Development\CS4001 SITE PLAN.dwg PLOTTED: 3/25/2022 1:42 PM, BY: Liliana Hernandez PLOTSTYLE: Pennoni NCS.stb PROJECT STATUS: CONSTRUCTION DRAWINGSBYNO.DATEREVISIONSRRMMX21005 AS NOTED CJM 2021-11-18 RAMAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK00 30'60' GRAPHIC SCALE 1"=30'PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493NORTH100% CD PLAN SET 01/31/2022  03/25/2022 FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VA. 22604SITE PLANCS4001 TOTAL SHEETS 17INDIAN HOLLOW ELEMENTARY SCHOOLMINOR RENOVATIONS AND REPAIRSCONSTRUCTION DRAWINGS1548 NORTH HAYFIELD RD. | WINCHESTER, VA. 22603GAINESBORO MAGISTERIAL DISTRICTDAVID L. FRANK Lic. No.1061 EMERGENCY ACCESS LANE FOR SECTION SEE CS4500 INSET AINV. (762.31)12" PVC INV. (766.82) 1 2 " P V C I N V . ( 7 6 7 . 5 8 ) C O M BGRATE (779.00)IN (767.00)OUT (766.80)R I M ( 7 7 9 . 6 8 ) IN ( 7 7 2 . 0 8 ) O U T ( 7 7 1 . 9 8 ) R I M ( 7 7 6 . 5 2 ) IN ( 7 7 0 . 2 2 ) O U T ( 7 7 0 . 0 2 ) AS P H A L T CONC. WALKC O N C . W A L K A S P H A L T A S P H A L T CONC. WALKCONC. WALK CONC. WALKASPHALT ASPHALTP L A Y G R O U N D P L A Y G R O U N DPLAYGROUNDP L A Y G R O U N D P L A Y G R O U N D PLAYGROUNDPLAYGROUNDPLAYGROUNDP L A Y G R O U N D A S P H A L T T R A C K P L A Y G R O U N D CONC. WALK C O N C R E T E ASPHALTCONC. G R A S S G R A S S G R A S S G R A S S GRASSGRA S S ME T A L R A M P CONC. WALKEX. MOBILECLASSROOM 4(910 SF)EX. MOBILECLASSROOM 1(910 SF)EX. MOBILECLASSROOM 2(952 SF)EX. MOBILECLASSROOM 3(952 SF)CONC.30" RCP3 0 " RCP 30" R C P 6 " P V C C O N C R E T E G E N E R A T O R B U I L D I N G F . F . E . ( 7 8 0 . 4 9 ) F . F . E . ( 7 8 0 . 4 7 ) F . F . E . ( 7 8 0 . 4 9 ) F . F . E . ( 7 8 0 . 5 1 ) M P M P W P C O W P W P WP C O C O C O C O G R A T E ( 7 7 8 . 6 8 ) O U T ( 7 6 9 . 3 8 ) GR A T E ( 7 7 7 . 2 8 ) IN ( 7 6 8 . 2 8 ) OU T ( 7 6 8 . 0 8 ) PI N 4 0 - A - 3 1 A C O U N T Y S C H O O L B O A R D O F F R E D E R I C K C O U N T Y VI R G I N I A D B 6 0 5 P G 7 8 5 ZO N E D : R A U S E : S C H O O LPIN 40-A-37ASHALLEN PROPERTIES, LLCINST. 200012199ZONED: RAUSE: AGRICULTURALB R I C K S C H O O L B U I L D I N G "I N D I A N H O L L O W E L E M E N T A R Y S C H O O L " (5 9 , 8 9 0 S F )OVERHANGA / C C O N C . L O A D I N G R A M P F U E L S T O R A G E E X C T R L P A N E L EXISTING TREELINEEXISTING TREELINEA P P R O X . L O C A T I O N O F T I M E C A P S U L E A P P R O X . L O C A T I O N O F E X . LA N D M A R K T R E E S W H H ( A P P R O X . ) A S P H A L T P A R K I N G L O TEX. ADAACCESSIBLE ROUTEWP w/ELEC.OUTLET7 7 9 0 0 E X R IM779.507878.23%78618 EX7997987977967957947937927917907897887867857865.61%2.00%5.61%790782 781 780 7807817827847857867797787797797 8 1 7 8 0794367939579596 HP79444795387988078430 7 8 0 4 0 7 8 0 2 0 7 7 9 6 0 776 30 7 7 9 2 0 7 8 0 1 0 7 7 9 9 0 7 8 0 1 0 7 8 0 0 0 7 8 0 0 0 7 8 0 0 0 7 8 0 0 0 7 7 9 1 0 7 8 0 0 0 7 7 9 9 0 7 8 0 0 0 7 7 8 5 0 7 7 9 5 0 7 7 8 3 0 7 7 8 1 07 7 8 0 0 7 7 7 5 0 7 7 7 3 0 7 7 7 1 0 7 7 7 0 0 7 7 7 0 077640 77640783 784 7 7 9 3 0 7 7 9 5 0 7 8 0 5 0 7 8 1 8 5 3.58%7 7 9 7 0 L P 7 8 0 6 0 E X 8. 0 0%2.00%7837807 8 0 3 077860 7 7 9 8 0 7 8 0 5 1 F F E 7 8 0 4 9 F F E 7 8 0 4 7 F F E 7 8 0 4 9 F F E 77778400 7 7 7 6 9 7 8 0 2 0 7 7 7 7 0 795790785 775770 77 5 78 0 7817 8 1 780779 794793792791789788787786 801 78 0 785 790795800 77 8 77877977 9 78178278 3 784 786 787788789791792793794796797798799 7 8 0 780784780770775775 7717727 7 3 774776 776 777 777778 778779779775770765762775 7 7 2771772773774775776 780 779779784783 7857857 8 4 7 8 2780785790 782 783784 7 8 2 7 8 4 7817 8 0 7 8 5 780 785 7 7 9 7 7 8778 7 7 7 77 6 7 7 7 774 772 773 771 770 1.00%7 7 7 4 0 7 7 7 4 0 7 7 7 0 0 7 7 7 2 0 7 7 6 9 0 7 7 7 2 0 H P 7 7 6 5 0 7 7 6 5 0 7 7 6 5 0 7 7 5 0 0 I N V 7 7 3 0 0 I N V 7 7 4 0 0 I N V 7 7 3 2 0 I N V 7 8 0 4 0 7 8 0 4 0 7 8 0 4 0 7 8 0 5 0 E X 7 8 0 3 0 7 8 0 4 0 7767807 7 9 7 0 7 8 0 2 0779 7 7 4 8 3 I N V 7 7 4 3 3 I N V 7 7 4 8 3 I N V FIRE LANE INSTALLEDAT GRADE TO MAINTAINSHEET FLOWFIRE LANE INSTALLEDAT GRADE TO MAINTAINSHEET FLOWDI-7 WITH TYPEA-III GRATEDI-1 WITH TYPEA-III GRATE147 LF EC-3 LINING10-YR WSEL780.3510-YR WSEL778.75OVERLANDRELIEF78382EX 7 8 1 8 8 EX 7 8 0 9 7 EX 2-15" HDPE11.1A11A10.1A10A6A6.1A5.3EX5.2EX 5EX5.13230" HDPE(4) 12" SDR-35DEPRESSED FOR OVERFLOWOVERLAND DRAINAGE OPTION II(2) 12" SDR-35DEPRESSED FOR OVERFLOWOVERLAND DRAINAGE OPTION I9 LF 4" PVC SCH-40UNDEDRAIN@ 1.00% MIN75 LF4" PVC SCH-40UNDERDRAIN @ 1.00% MINWITH SCREEN77 LF 4" PVC SCH-40UNDERDRAIN @ 1.00% MINWITH SCREEN58 LF 4" PVC SCH-40UNDERDRAIN @ 1 .00% M INWITH SCREEN5.418" HDPETP TP T P T P TEST PITEX. UTILITIESTP3 - SECURED BOLLARDSNOT REMOVABLE BY THEGENERAL PUBLICR E S T R O OM 10'X18' VDOT CLI RIPRAP( 4 2 8 S F )PR. MOBILECLASSROOM 6(793 SF)PR. MOBILECLASSROOM 5(793 SF)MOBILE CLASSROOMS &DECK LANDING TO MATCH EX.DECK LANDING FFE33'x14' DECKING WITH 42"RAILING AT LOCATIONS A, B, & CFINAL FLOOR OF RESTROOM& DECKING TO MATCH EX.DECKING ELEVATIONNEW STAIRS - NO. OF RISERS AS REQUIRED BYTHE BUILDING CODE TO MEET FINAL GRADE.MAX 7" RISERS, MIN 10" TREADS. GREATESTRISER HEIGHT AND TREAD DEPTH WITHIN ANYFLIGHT OF STAIRS NOT TO EXCEED THESMALLEST BY 38"21'x10' DECKING WITH 42"RAILING AT LOCATIONS D & EEX CTRL PANEL7827817807817827800077910780007799078000778507837847793077950780507818577970 LP 78060 EX 7797477990 77968 779137837807803077860 780779778779784783785785784782780782784782779EX78188EX78097EX5.3EX5.230" HDPE5.418" HDPETO BE REMOVED6 - 4" PROP MEP CONDUITS1 PROP MEP CONDUITSEX TRANSFORMER PADDIMENSIONS TO BEVERIFIED WITH FINALELECTRICAL DESIGN PLANSADAACCESSIBLEROUTE2% - 3.5%SLOPESU:\Accounts\RRMMX\RRMMX21005 - Indian Hollow ES Renovation\DESIGN\_SHEETS\02-Design Development\CS4100 Grading Plan.dwg PLOTTED: 3/25/2022 1:43 PM, BY: Liliana Hernandez PLOTSTYLE: Pennoni NCS.stb PROJECT STATUS: CONSTRUCTION DRAWINGS BYNO.DATE REVISIONSRRMMX21005AS NOTEDCJM2021-11-18RAMAPPROVED BYDRAWN BYDRAWING SCALEDATEPROJECTALL DOCUMENTS PREPARED BY PENNONI ASSOCIATESARE INSTRUMENTS OF SERVICE IN RESPECT OF THEPROJECT. THEY ARE NOT INTENDED OR REPRESENTEDTO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ONTHE EXTENSIONS OF THE PROJECT OR ON ANY OTHERPROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATIONOR ADAPTATION BY PENNONI ASSOCIATES FOR THESPECIFIC PURPOSE INTENDED WILL BE AT OWNERSSOLE RISK AND WITHOUT LIABILITY OR LEGALEXPOSURE TO PENNONI ASSOCIATES; AND OWNERSHALL INDEMNIFY AND HOLD HARMLESS PENNONIASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES ANDEXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTOR AND OWNER MUST BE NOTIFIED OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK0030'60'GRAPHIC SCALE 1"=30'PENNONI ASSOCIATES INC. 117 East Piccadilly Street Winchester, VA 22601 T 540.667.2139 F 540.665.0493 NOR T H100% CD PLAN SET 01/31/2022  03/25/2022 FREDERICK COUNTY PUBLIC SCHOOLS PO BOX 3508 | WINCHESTER, VA. 22604 GRADING PLANCS4100TOTAL SHEETS17INDIAN HOLLOW ELEMENTARY SCHOOL MINOR RENOVATIONS AND REPAIRS CONSTRUCTION DRAWINGS 1548 NORTH HAYFIELD RD. | WINCHESTER, VA. 22603 GAINESBORO MAGISTERIAL DISTRICTINSET A - AC AREA PHASE 2 GRADING PLANSCALE: 1" = 20'0020'40'GRAPHIC SCALE 1"=20'DAVID L. FRANKLic. No.1061EMERGENCY ACCESS LANEFOR SECTION SEE CS4500 CONCRETE SIDEWALK NTS 4" CONCRETE 4" DENSE GRADED STONE (21B) COMPACTED SUBGRADE 1 2":1' EMERGENCY ACCESS LANE TYPICAL SECTION NTS 10' 12" 21B COMPACTED SUBGRADE 10' 20' 24' 2' SHOULDER 2' SHOULDER 1":1' 1":1' UD-4 NOTES: 1. 4" MINIMUM, PROVIDED ATTAINING 4" OF AGGREGATE ON TOP OF PIPE 2. OUTLET PIPES ARE TO BE INSTALLED ON 2% MIN. (3% DESIRABLE) GRADE AND LOCATED EVERY 350' MAXIMUM OR AS NOTED ON PLANS. GEOTEXTILE DRAINAGE FABRIC (OVERLAP 1' AT TOP) 4" PIPE OUTLET PIPE WITH "RODENT PROOF" COVER/GRATE 1'#57 AGGREGATE, #8 AGGREGATE OR CRUSHED GLASS MEETING #8 GRADATION REQUIREMENT U:\Accounts\RRMMX\RRMMX21005 - Indian Hollow ES Renovation\DESIGN\_SHEETS\02-Design Development\CS4500 Site Details.dwg PLOTTED: 3/25/2022 1:43 PM, BY: Liliana Hernandez PLOTSTYLE: Pennoni NCS.stb PROJECT STATUS: CONSTRUCTION DRAWINGSBYNO.DATEREVISIONSRRMMX21005 AS NOTED CJM 2021-11-18 RAMAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORKPENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493100% CD PLAN SET 01/31/2022  03/25/2022 FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VA. 22604SITE DETAILSCS4500 TOTAL SHEETS 17INDIAN HOLLOW ELEMENTARY SCHOOLMINOR RENOVATIONS AND REPAIRSCONSTRUCTION DRAWINGS1548 NORTH HAYFIELD RD. | WINCHESTER, VA. 22603GAINESBORO MAGISTERIAL DISTRICTDAVID L. FRANK Lic. No.1061 7707707 7 0 764764766766768768772772772774774780 790 800 810 820 830 840 776 778782784786 788 792 794 796 798 802 804 806 808 812 814 816 818 822 824 826 828 832 834836838 750760 770 752754 756 758 762 764 766 7687727 7 4 7 5 0 7 6 0 77074 47467487 5 2 7 5 4 756 7 5 8 7 6 2 7 6 4 7 6 6768 772IN V . ( 7 6 0 . 0 1 )15" RCPINV. (761.97)INV. (762.31)12" PVC INV. (766.82) 1 2 " P V C I N V . ( 7 6 7 . 5 8 ) C O M B IN V . ( 7 5 8 . 3 9 ) IN V . ( 7 5 7 . 9 2 ) 1 8 " R C P IN V . ( 7 5 8 . 0 2 ) 18" R C P IN V . ( 7 5 9 . 7 5 )GRATE (779.00)IN (767.00)OUT (766.80)G R A T E ( 7 8 3 . 3 7 ) O U T ( 7 8 2 . 4 7 ) (4 ) 4 " P E P P I P E S (D I R . U N K . )RIM (772.65)IN (767.65)OUT (767.45)ASP H A L T CONC. WALK C O N C . W A L K A S P H A L T A S P H A L T CONC. WALKCONC. WALK CONC. WALKASPHALT A S P H A L T P A R K I N G L O T A S P H A L T M E T A L G U A R D R A I L ASPHALT ASPHALTASPHALTP L A Y G R O U N D P L A Y G R O U N DPLAYGROUNDP L A Y G R O U N D PLAYGROUNDPLAYGROUNDPLAYGROUNDPLAYGROUNDP L A Y G R O U N D A S P H A L T T R A C K A S P H A L T T R A C K P L A Y G R O U N D CONC. WALK C O N C R E T E ASPHALTC O N C . W A L K C O N C . W A L K CONC. G R A S S G R A S S G R A S S G R A S S G R A S S G R A S S G R A S S G R A S S G R A S S G R A S S G R A S S M E T A L R A M P CONC. WALKEX. MOBILECLASSROOM 4(910 SF)EX. MOBILECLASSROOM 1(910 SF)EX. MOBILECLASSROOM 2(952 SF)EX. MOBILECLASSROOM 3(952 SF)CONC.BATTINGCAGE1 5 " P V C R I M ( 7 6 7 . 1 0 ) IN V . ( 7 6 2 . 6 0 )EXISTINGWWTP30" RCP3 0 " RC P 30" R C P 15" RCPA / CA / C C O N C R E T E G E N E R A T O R B U I L D I N G F U E L T A N K F . F . E . ( 7 8 0 . 4 9 ) F . F . E . ( 7 8 0 . 4 7 ) F . F . E . ( 7 8 0 . 4 9 ) F . F . E . ( 7 8 0 . 5 1 ) M P M P W P M P W P W P W P C O C O G R A T E ( 7 7 8 . 6 8 ) O U T ( 7 6 9 . 3 8 ) GRA T E ( 7 7 7 . 2 8 ) IN (7 6 8 . 2 8 ) OUT ( 7 6 8 . 0 8 ) PI N 4 0 - A - 3 1 A C O U N T Y S C H O O L B O A R D O F F R E D E R I C K C O U N T Y VI R G I N I A D B 6 0 5 P G 7 8 5 ZO N E D : R A U S E : S C H O O LPIN 40-A-37ASHALLEN PROPERTIES, LLCINST. 200012199ZONED: RAUSE: AGRICULTURALPIN 40-A-37ASHALLEN PROPERTIES, LLCINST. 200012199ZONED: RAUSE: AGRICULTURALPIN 40-A-1GERRY O FARM, LLCINST. 080000074ZONED: RAUSE: AGRICULTURALPIN 40-A-31CRAIG PEARRELLINST. 200004147ZONED: RAUSE: RESIDENTIALPIN 40-A-32AHERBERT L. FELTNERDB 296 PG 108ZONED: RAUSE: RESIDENTIALPIN 40-A-34HERBERT L. FELTNERDB 312 PG 654ZONED: RAUSE: RESIDENTIALPIN 40-A-10ALEONI WERTHEIMINST. 110009185ZONED: RAUSE: AGRICULTURALVA. SEC. RTE. 600N. HAYFIELD ROADB R I C K S C H O O L B U I L D I N G "I N D I A N H O L L O W E L E M E N T A R Y S C H O O L " (5 9 , 8 9 0 S F )OVERHANGA / C R I M ( 7 7 7 . 2 2 ) O U T ( 7 7 1 . 9 2 ) IND IAN HOLLOW ROAD C O N C . L O A D I N G R A M P F U E L S T O R A G E U / G O I L T A N K (A P P R O X . ) E X C T R L P A N E L EXISTING TREELINEEXISTING TREELINEW H H ( A P P R O X . ) A S P H A L T P A R K I N G L O TEX. ADAACCESSIBLE ROUTEA S P H A L T P A R K I N G L O TWP w/ELEC.OUTLET41B13B13B13B41B3C3C40B13C14C17E41D41C3C13B41B41C41C13D17E3CDA ( 1 ) TO PONDTOTAL AREA = 12.20 AC.IMPERVIOUS = 4.30 AC.B SOIL = 2.05 AC.C SOIL = 0.60 AC.D SOIL = 5.08 AC.CN = 86TC = 20 MIN.DA #1STUDY POINT7707707 7 0 764764766766768768772772772774774780 790 800 810 820 830 840 776 778782784786 788 792 794 796 798 802 804 806 808 812 814 816 818 822 824 826 828 832 834836838 750760 770 752754 756 758 762 764 766 7687727 7 4 7 5 0 7 6 0 77074 47467487 5 2 7 5 4 756 7 5 8 7 6 2 7 6 4 7 6 6768 772M B ASP H A L T CONC. WALK C O N C . W A L K A S P H A L T A S P H A L T CONC. WALKCONC. WALK CONC. WALKASPHALT A S P H A L T P A R K I N G L O T A S P H A L T ASPHALT ASPHALTASPHALTP L A Y G R O U N D P L A Y G R O U N DPLAYGROUNDP L A Y G R O U N D PLAYGROUNDPLAYGROUNDPLAYGROUNDPLAYGROUNDP L A Y G R O U N D A S P H A L T T R A C K A S P H A L T T R A C K P L A Y G R O U N D CONC. WALK C O N C R E T E ASPHALTC O N C . W A L K C O N C . W A L K CONC. G R A S S G R A S S G R A S S G R A S S G R A S S G R A S S G R A S S G R A S S G R A S S G R A S S M E T A L R A M P CONC. WALKEX. MOBILECLASSROOM 4(910 SF)EX. MOBILECLASSROOM 1(910 SF)EX. MOBILECLASSROOM 2(952 SF)EX. MOBILECLASSROOM 3(952 SF)CONC.BATTINGCAGEEXISTINGWWTPC O N C R E T E G E N E R A T O R B U I L D I N G F . F . E . ( 7 8 0 . 4 9 ) F . F . E . ( 7 8 0 . 4 7 ) F . F . E . ( 7 8 0 . 4 9 ) F . F . E . ( 7 8 0 . 5 1 ) M P M P W P W P W P W P PI N 4 0 - A - 3 1 A C O U N T Y S C H O O L B O A R D O F F R E D E R I C K C O U N T Y VI R G I N I A D B 6 0 5 P G 7 8 5 ZO N E D : R A U S E : S C H O O LPIN 40-A-37ASHALLEN PROPERTIES, LLCINST. 200012199ZONED: RAUSE: AGRICULTURALPIN 40-A-37ASHALLEN PROPERTIES, LLCINST. 200012199ZONED: RAUSE: AGRICULTURALPIN 40-A-1GERRY O FARM, LLCINST. 080000074ZONED: RAUSE: AGRICULTURALPIN 40-A-31CRAIG PEARRELLINST. 200004147ZONED: RAUSE: RESIDENTIALPIN 40-A-32AHERBERT L. FELTNERDB 296 PG 108ZONED: RAUSE: RESIDENTIALPIN 40-A-34HERBERT L. FELTNERDB 312 PG 654ZONED: RAUSE: RESIDENTIALPIN 40-A-10ALEONI WERTHEIMINST. 110009185ZONED: RAUSE: AGRICULTURALVA. SEC. RTE. 600N. HAYFIELD ROADB R I C K S C H O O L B U I L D I N G "I N D I A N H O L L O W E L E M E N T A R Y S C H O O L " (5 9 , 8 9 0 S F )OVERHANGA / C IND IAN HOLLOW ROAD C O N C . L O A D I N G R A M P F U E L S T O R A G E E X C T R L P A N E L EXISTING TREELINEEXISTING TREELINEW H H ( A P P R O X . ) A S P H A L T P A R K I N G L O TEX. ADAACCESSIBLE ROUTEA S P H A L T P A R K I N G L O TWP w/ELEC.OUTLET41B13B13B13B41B3C3C40B13C14C17E41D41C3C13B41B41C41C13D17E3CDA ( 1C ) TO PONDTOTAL AREA = 12.2 AC.IMPERVIOUS = 4.30 AC.B SOIL = 2.05 AC.C SOIL = 0.60 AC.D SOIL = 5.08 AC.CN = 86TC = 21 MIN.0.89 AC. OF HSG-( C ) SOILDRAINING THRU TREECONSERVATION AREA0.78 AC. OF HSG-( B ) SOILDRAINING THRU TREECONSERVATION AREA3.06 AC. OF HSG-( D ) SOILDRAINING THRU TREECONSERVATION AREA3.85 AC TOSTR #6.1A0.36 AC TOSTR #5.40.36 AC TOSTR #5.3DA #1STUDY POINTMECHANICAL UNITS(SEE ARCHITECTURAL PLANS)MECHANICAL UNITS(SEE ARCHITECTURAL PLANS)U:\Accounts\RRMMX\RRMMX21005 - Indian Hollow ES Renovation\DESIGN\_SHEETS\02-Design Development\CS5200 Drainage Divides.dwg PLOTTED: 3/25/2022 1:44 PM, BY: Liliana Hernandez PLOTSTYLE: Pennoni NCS.stb PROJECT STATUS: CONSTRUCTION DRAWINGS BYNO.DATE REVISIONSRRMMX21005AS NOTEDCJM2021-11-18RAMAPPROVED BYDRAWN BYDRAWING SCALEDATEPROJECTALL DOCUMENTS PREPARED BY PENNONI ASSOCIATESARE INSTRUMENTS OF SERVICE IN RESPECT OF THEPROJECT. THEY ARE NOT INTENDED OR REPRESENTEDTO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ONTHE EXTENSIONS OF THE PROJECT OR ON ANY OTHERPROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATIONOR ADAPTATION BY PENNONI ASSOCIATES FOR THESPECIFIC PURPOSE INTENDED WILL BE AT OWNERSSOLE RISK AND WITHOUT LIABILITY OR LEGALEXPOSURE TO PENNONI ASSOCIATES; AND OWNERSHALL INDEMNIFY AND HOLD HARMLESS PENNONIASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES ANDEXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTOR AND OWNER MUST BE NOTIFIED OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK00100'200'GRAPHIC SCALE 1"=100'PENNONI ASSOCIATES INC. 117 East Piccadilly Street Winchester, VA 22601 T 540.667.2139 F 540.665.0493 NOR T H 100% CD PLAN SET 01/31/2022 03/25/2022 FREDERICK COUNTY PUBLIC SCHOOLS PO BOX 3508 | WINCHESTER, VA. 22604 DRAINAGE DIVIDESCS5200TOTAL SHEETS17INDIAN HOLLOW ELEMENTARY SCHOOL MINOR RENOVATIONS AND REPAIRS CONSTRUCTION DRAWINGS 1548 NORTH HAYFIELD RD. | WINCHESTER, VA. 22603 GAINESBORO MAGISTERIAL DISTRICT DAVID L. FRANKLic. No.1061EXISTING CONDITION00100'200'GRAPHIC SCALE 1"=100'NOR T HPOST CONDITION 3 - SECURED BOLLARDSNOT REMOVABLE BY THEGENERAL PUBLICR E S T R O O M 3 6 . 6 7 '11.67'2 3 . 3 3 '34'34'MECHANICAL UNITS(SEE ARCHITECTURAL PLANS)MECHANICAL UNITS(SEE ARCHITECTURAL PLANS)10'X18' VDOT CLI RIPRAP(4 2 8 S F )PR. MOBILECLASSROOM 6(793 SF)PR. MOBILECLASSROOM 5(793 SF)A B C 8'14'3 3 'MOBILE CLASSROOMS &DECK LANDING TO MATCH EX.DECK LANDING FFE33'x14' DECKING WITH 42"RAILING AT LOCATIONS A, B, & CFINAL FLOOR OF RESTROOM& DECKING TO MATCH EX.DECKING ELEVATIONNEW STAIRS - NO. OF RISERS AS REQUIRED BYTHE BUILDING CODE TO MEET FINAL GRADE.MAX 7" RISERS, MIN 10" TREADS. GREATESTRISER HEIGHT AND TREAD DEPTH WITHIN ANYFLIGHT OF STAIRS NOT TO EXCEED THESMALLEST BY 38"21'x10' DECKING WITH 42"RAILING AT LOCATIONS D & ED E 10'2 1 ' 2 3 . 3 3 ' M B ASP H A L T CONC. WALKC O N C . W A L K A S P H A L T A S P H A L T CONC. WALKCONC. WALK CONC. WALKASPHALT A S P H A L T P A R K I N G L O T A S P H A L T M E T A L G U A R D R A I L ASPHALT ASPHALTASPHALTP L A Y G R O U N D P L A Y G R O U N DPLAYGROUNDP L A Y G R O U N D PLAYGROUNDPL A Y G R O U N DPLAYGROUNDPLAYGROUNDP L A Y G R O U N D A S P H A L T T R A C K A S P H A L T T R A C K P L A Y G R O U N D CONC. WALK C O N C R E T E ASPHALTC O N C . W A L K C O N C . W A L K CONC. G R A S S G R A S S G R A S S G R A S S G R A S S G R A S S G R A S S G R A S S G R A S S G R A S S G R A S S M E T A L R A M P CONC. WALKEX. MOBILECLASSROOM 4(910 SF)EX. MOBILECLASSROOM 1(910 SF)EX. MOBILECLASSROOM 2(952 SF)EX. MOBILECLASSROOM 3(952 SF)CONC.BATTINGCAGEEXISTINGWWTPA / CA / C C O N C R E T E G E N E R A T O R B U I L D I N G F U E L T A N K F . F . E . ( 7 8 0 . 4 9 ) F . F . E . ( 7 8 0 . 4 7 ) F . F . E . ( 7 8 0 . 4 9 ) F . F . E . ( 7 8 0 . 5 1 ) M P M P W P M P W P W P W P PI N 4 0 - A - 3 1 A C O U N T Y S C H O O L B O A R D O F F R E D E R I C K C O U N T Y VI R G I N I A D B 6 0 5 P G 7 8 5 ZO N E D : R A U S E : S C H O O LPIN 40-A-37ASHALLEN PROPERTIES, LLCINST. 200012199ZONED: RAUSE: AGRICULTURALPIN 40-A-37ASHALLEN PROPERTIES, LLCINST. 200012199ZONED: RAUSE: AGRICULTURALPIN 40-A-1GERRY O FARM, LLCINST. 080000074ZONED: RAUSE: AGRICULTURALPIN 40-A-31CRAIG PEARRELLINST. 200004147ZONED: RAUSE: RESIDENTIALPIN 40-A-32AHERBERT L. FELTNERDB 296 PG 108ZONED: RAUSE: RESIDENTIALPIN 40-A-34HERBERT L. FELTNERDB 312 PG 654ZONED: RAUSE: RESIDENTIALPIN 40-A-10ALEONI WERTHEIMINST. 110009185ZONED: RAUSE: AGRICULTURALVA. SEC. RTE. 600N. HAYFIELD ROADB R I C K S C H O O L B U I L D I N G "I N D I A N H O L L O W E L E M E N T A R Y S C H O O L " (5 9 , 8 9 0 S F )OVERHANGA / C IND IAN HOLLOW ROAD C O N C . L O A D I N G R A M P F U E L S T O R A G E U / G O I L T A N K (A P P R O X . ) E X C T R L P A N E L EXISTING TREELINEEXISTING TREELINEA P P R O X . L O C A T I O N O F T I M E C A P S U L E A P P R O X . L O C A T I O N O F E X . LA N D M A R K T R E E S W H H ( A P P R O X . ) A S P H A L T P A R K I N G L O TEX. ADAACCESSIBLE ROUTEA S P H A L T P A R K I N G L O TWP w/ELEC.OUTLET3.37 ACTREE CONSERVATIONEASEMENTL1L2L3L 4L5L6L7L 8L9L10L11L12L13L14L15L16L17L18L19C1L20C2L21C3L22C4 L23C5L24L25 L26L27L28 L29 L30 EASEMENT LINE TABLELINE #L1L2L3L4L5L6L7L8L9L10L11L12L13L14L15L16L17L18L19L20BEARINGS 71°00'10" WN 80°19'43" WN 79°16'40" WN 85°32'58" WN 81°59'43" WN 70°02'03" WN 67°25'52" WN 87°49'50" WN 71°56'29" WN 83°48'18" WN 76°51'31" WN 75°17'39" WN 83°03'12" WS 45°56'53" WS 19°54'36" WS 11°43'33" WS 35°12'23" WS 08°25'35" WS 08°25'35" WS 48°40'11" EDISTANCE13.29'56.71'79.94'45.97'64.14'36.12'59.76'49.96'44.02'51.94'68.07'51.95'19.40'20.44'94.54'87.23'51.74'15.58'13.25'18.73'EASEMENT LINE TABLELINE #L21L22L23L24L25L26L27L28L29L30BEARINGS 15°27'02" ES 64°05'55" ES 02°54'31" ES 07°11'01" WS 50°17'37" WS 41°51'58" WS 22°35'18" WS 58°13'23" WS 52°53'01" WS 41°49'49" WDISTANCE20.94'16.91'19.97'7.12'24.45'21.75'17.91'24.27'51.86'38.53'EASEMENT CURVE TABLECURVE #C1C2C3C4C5RADIUS32.00'43.00'32.00'28.00'93.00'DELTA057°05'46"033°13'09"048°38'53"061°11'24"010°05'32"ARC LENGTH31.89'24.93'27.17'29.90'16.38'TANGENT17.4112.8314.4616.568.21CHORD LENGTH30.59'24.58'26.36'28.50'16.36'CHORD BEARINGS 20°07'18" ES 32°03'37" ES 39°46'29" ES 33°30'13" ES 02°08'15" WU:\Accounts\RRMMX\RRMMX21005 - Indian Hollow ES Renovation\DESIGN\_SHEETS\02-Design Development\CS5300 Water quality.dwg PLOTTED: 3/25/2022 2:07 PM, BY: Liliana Hernandez PLOTSTYLE: Pennoni NCS.stb PROJECT STATUS: CONSTRUCTION DRAWINGS BYNO.DATE REVISIONSRRMMX21005AS NOTEDCJM2021-11-18RAMAPPROVED BYDRAWN BYDRAWING SCALEDATEPROJECTALL DOCUMENTS PREPARED BY PENNONI ASSOCIATESARE INSTRUMENTS OF SERVICE IN RESPECT OF THEPROJECT. THEY ARE NOT INTENDED OR REPRESENTEDTO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ONTHE EXTENSIONS OF THE PROJECT OR ON ANY OTHERPROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATIONOR ADAPTATION BY PENNONI ASSOCIATES FOR THESPECIFIC PURPOSE INTENDED WILL BE AT OWNERSSOLE RISK AND WITHOUT LIABILITY OR LEGALEXPOSURE TO PENNONI ASSOCIATES; AND OWNERSHALL INDEMNIFY AND HOLD HARMLESS PENNONIASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES ANDEXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTOR AND OWNER MUST BE NOTIFIED OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK PENNONI ASSOCIATES INC. 117 East Piccadilly Street Winchester, VA 22601 T 540.667.2139 F 540.665.0493100% CD PLAN SET 01/31/2022 03/25/2022 FREDERICK COUNTY PUBLIC SCHOOLS PO BOX 3508 | WINCHESTER, VA. 22604 WATER QUALITYCS5300TOTAL SHEETS17INDIAN HOLLOW ELEMENTARY SCHOOL MINOR RENOVATIONS AND REPAIRS CONSTRUCTION DRAWINGS 1548 NORTH HAYFIELD RD. | WINCHESTER, VA. 22603 GAINESBORO MAGISTERIAL DISTRICT DAVID L. FRANKLic. No.1061CONSERVATION EASEMENTEXHIBIT00100'200'GRAPHIC SCALE 1"=100'NOR T H 12" COUNTER SINKEX. 18" RCP OUTLET PIPEPIPE INVERT3.5" ORIFICE ATINVERT OF EX. 18"RCP OUTLET PIPE4" STEEL PLATEENERGY BALANCE PLATEDETAIL (NTS)INDIAN HOLLOW ELEMENTARY SCHOOL STORMWATER MANAGEMENT NARRATIVEOVERVIEWTHE "INDIAN HOLLOW ELEMENTARY SCHOOL" PROJECT SITE IS LOCATED IN FREDERICK COUNTY, VIRGINIA WITHIN THE GAINESBORO MAGISTERIALDISTRICT. THIS SITE IS SPECIFICALLY LOCATED ON THE WEST SIDE OF NORTH HAYFIELD ROAD (ROUTE 600), NORTH OF NORTHWESTERN PIKE(ROUTE 50). THIS +/- 19.5-ACRE PROPERTY IS IDENTIFIED AS PROPERTY IDENTIFICATION NUMBER 40-A-31-A, IS OWNED BY THE FREDERICK COUNTYSCHOOL BOARD AND IS CURRENTLY ZONED RA. ALL DRAINAGE FROM THE SITE AND SURROUNDING PROPERTIES DRAINS TOWARD AN UNNAMEDTRIBUTARY OF HOGUE CREEK. THE SITE IS CURRENTLY AN EXISTING ELEMENTARY SCHOOL WITH IMPERVIOUS, MANAGED TURF AND FORESTEDAREAS WITH SLOPES GENERALLY RANGING FROM LESS THAN 1.0% TO APPROXIMATELY 50%.THIS PROJECT PROPOSES THE RENOVATION OF THE EXISTING SCHOOL BUILDING CONSTRUCTED IN 1988. THE PROJECT IS STRICTLY DRIVEN BYARCHITECTURAL UPGRADES AND IMPROVEMENTS; HOWEVER, THESE IMPROVEMENTS WILL TRIGGER THE CONSTRUCTION OF MINOR GRAVEL FIRELANE EXTENSIONS AND BUILDING PERIMETER DRAINAGE IMPROVEMENTS. SITE IMPACTS OUTSIDE OF THE BUILDING ARE MINIMAL AND LINEAR INNATURE DUE TO UTILITY UPGRADES. THE EXISTING STORMWATER MANAGEMENT FACILITIES WILL CONTINUE TO ADEQUATELY MEET THE MINIMUMSTORMWATER QUANTITY REQUIREMENTS. PLACING THE UNDISTURBED WOODED AREAS OF THE PROPERTY INTO CONSERVATION EASEMENT INADDITION TO THE EXISTING FACILITIES WILL MEET THE MINIMUM STORMWATER QUALITY REQUIREMENTS.PRE-DEVELOPMENT CONDITIONSTHE ELEMENTARY SCHOOL WAS CONSTRUCTED IN A RURAL AREA AND IS GENERALLY SURROUNDED BY MANAGED AGRICULTURAL FIELD LAND USES.THE AREAS OF THE SITE IMPACTED BY THE PROPOSED IMPROVEMENTS DISCHARGE SURFACE RUNOFF IN TWO GENERAL DIRECTIONS. THE PRIMARYDRAINAGE AREA IS THAT WHICH CONTRIBUTES TO THE EXISTING STORMWATER DETENTION POND CONSTRUCTED WITH THE 1988 SITE PLAN. THEREARE UNCONTROLLED AREAS DRAINING OF-SITE IN A SOUTHERLY DIRECTION. THE SECONDARY DRAINAGE AREA STUDIED IS ONE OF THESEUNCONTROLLED DRAINAGE SHEDS ON THE SOUTHERN SIDE OF THE EXISTING STRUCTURE.POST-DEVELOPMENT CONDITIONSTHE POST-DEVELOPMENT DRAINAGE PATTERNS ARE IDENTICAL TO THE PRE-DEVELOPMENT DRAINAGE PATTERNS. THE SITE STILL DISCHARGESSURFACE RUNOFF AT THE SAME LOCATIONS, HOWEVER, DRAINAGE IMPROVEMENTS AND THE ADDITION OF A GRAVEL FIRE LANE RESULTED WITH THESTUDY OF NEW SUB-SHEDS WITHIN THE PRIMARY DRAINAGE SHED. THE IMPROVEMENTS IN THE SECONDARY DRAINAGE SHED TO THE SOUTHRESULT IN CONTINUED SHEET FLOW DISCHARGE AS IT CURRENTLY DOES. THERE IS A 3.37-ACRE FORESTED AREA THAT WILL BE PRESERVED ANDPLACED WITHIN AN EASEMENT FOR THIS PROJECT TO ADEQUATELY MEET THE POST-DEVELOPMENT VRRM SWM WATER QUALITY DESIGNREQUIREMENTS.WATER QUALITY CONTROL (BMP)THE TOTAL PHOSPHORUS LOAD REDUCTION REQUIRED FOR THIS DEVELOPMENT IS 1.91 LBS/YEAR, AND THE TOTAL PHOSPHORUS LOAD REDUCTIONPROVIDED FOR BY THE PROJECT IS 1.89 LBS/YEAR. A TOTAL OF 0.02 LBS OF NUTRIENT CREDITS WILL BE SECURED THROUGH AN AUTHORIZEDNUTRIENT BANK. THE WATER QUALITY REQUIREMENTS FOR PHOSPHORUS LOAD REDUCTION ARE SATISFIED THROUGH PROVIDING CONTINUEDSHEET FLOW THROUGH A CONSERVED FORESTED AREA, UTILIZING THE EXISTING DRY POND AND PURCHASING THE REMAINING CREDITS.WATER QUANTITY CONTROL (SWM)WATER QUANTITY REQUIREMENTS FOR CHANNEL PROTECTION AND FLOOD PROTECTION ARE SATISFIED FOR THE PROJECT THROUGH AMODIFICATION OF THE EXISTING POND STRUCTURE ASSOCIATED WITH DRAINAGE AREA DA #1. STORMWATER INCREASES RESULTING FROM THEPROPOSED DISCONNECTED IMPERVIOUS AREAS OUTSIDE OF THE DRAINAGE AREA FLOWING TO THE EXISTING POND DO NOT INCREASEDOWN-GRADIENT EROSION, FLOODING, OR SEDIMENTATION. PER 9VAC25-870-66.D, NO FURTHER WATER QUANTITY CONTROL IS REQUIRED IN THEAREAS OUTSIDE OF DA#1.CHANNEL PROTECTIONFOR THE PRIMARY DRAINAGE SHED (DA #1) STUDY POINT, CHANNEL PROTECTION IS MET BY 9VAC25-870-66.B.1.B, SUCH THAT 9VAC25-870-66.B.3 HASBEEN SATISFIED. 9VAC25-870-66.B.3 IS SATISFIED BY MEETING THE REQUIREMENTS OF THE "ENERGY BALANCE EQUATION". THE OUTFALLSTRUCTURE MODIFICATION PROPOSED TO THE EXISTING POND IS PLACING A PLATE RESTRICTING FLOW AT THE LOWEST LEVELS ON THE STORMPOND. WHEN COUPLED BY THE INCREASE IN THE TIME OF CONCENTRATION WITH THE ADDITION OF THE DRAINAGE DITCHES AND OVERLAND FLOWPATH LENGTH, A REDUCTION IN PEAK FLOW RESULTED IN THE STORMWATER POND ROUTING WHICH IS SATISFYING THE CHANNEL PROTECTIONREQUIREMENTS OF 9VAC25-870-66.B.3. LIMITS OF ANALYSIS FOR CHANNEL PROTECTIONTHE LIMITS OF ANALYSIS FOR CHANNEL PROTECTION IS MET BY 9VAC25-870-66.B.4, SUCH THAT 9VAC25-870-66.B.3 HAS BEEN SATISFIED. 9VAC25-870-66.B.3 IS SATISFIED BY MEETING THE REQUIREMENTS OF THE "ENERGY BALANCE EQUATION". IN ADDITION THE PROJECT MEETS9VAC25-870.66.B.4.B, WHERE THE SITES PROPOSED PEAK FLOW RATE IS LESS THAN OR EQUAL TO THE EXISTING 24 HOUR 1-YEAR PEAK FLOW RATE.FLOOD PROTECTIONAT STUDY POINT 1, FLOOD PROTECTION IS MET BY 9VAC25-870-66.C.1, SUCH THAT THE POINT OF DISCHARGE RELEASES STORMWATER INTO ASTORMWATER CONVEYANCE SYSTEM THAT, FOLLOWING THE LAND-DISTURBING ACTIVITY, CONFINES THE POST DEVELOPMENT PEAK FLOW RATEFROM THE 10-YEAR 24-HOUR STORM EVENT WITHIN THE STORMWATER CONVEYANCE SYSTEM.LIMITS OF ANALYSIS FOR FLOOD PROTECTION9VAC25-870-66.C.3 HAS BEEN SATISFIED, SUCH THAT 9VAC25-870-66.C.2.B AND 9VAC25-870-66.C.3.B HAVE BEEN SATISFIED. 9VAC25-870-66.C.2.B ISSATISFIED BY RELEASING POST-DEVELOPMENT PEAK FLOW FOR THE 10 YEAR 24 HOUR STORM EVENT AT RATES THAT ARE LESS THAN THEPRE-DEVELOPMENT PEAK FLOW RATE FROM THE 10 YEAR 24 HOUR STORM EVENT.U:\Accounts\RRMMX\RRMMX21005 - Indian Hollow ES Renovation\DESIGN\_SHEETS\02-Design Development\CS5400 Water quantity.dwg PLOTTED: 3/25/2022 2:07 PM, BY: Liliana Hernandez PLOTSTYLE: Pennoni NCS.stb PROJECT STATUS: CONSTRUCTION DRAWINGS BYNO.DATE REVISIONSRRMMX21005AS NOTEDCJM2021-11-18RAMAPPROVED BYDRAWN BYDRAWING SCALEDATEPROJECTALL DOCUMENTS PREPARED BY PENNONI ASSOCIATESARE INSTRUMENTS OF SERVICE IN RESPECT OF THEPROJECT. THEY ARE NOT INTENDED OR REPRESENTEDTO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ONTHE EXTENSIONS OF THE PROJECT OR ON ANY OTHERPROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATIONOR ADAPTATION BY PENNONI ASSOCIATES FOR THESPECIFIC PURPOSE INTENDED WILL BE AT OWNERSSOLE RISK AND WITHOUT LIABILITY OR LEGALEXPOSURE TO PENNONI ASSOCIATES; AND OWNERSHALL INDEMNIFY AND HOLD HARMLESS PENNONIASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES ANDEXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTOR AND OWNER MUST BE NOTIFIED OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK PENNONI ASSOCIATES INC. 117 East Piccadilly Street Winchester, VA 22601 T 540.667.2139 F 540.665.0493100% CD PLAN SET 01/31/2022 03/25/2022 FREDERICK COUNTY PUBLIC SCHOOLS PO BOX 3508 | WINCHESTER, VA. 22604 WATER QUANTITYCS5400TOTAL SHEETS17INDIAN HOLLOW ELEMENTARY SCHOOL MINOR RENOVATIONS AND REPAIRS CONSTRUCTION DRAWINGS 1548 NORTH HAYFIELD RD. | WINCHESTER, VA. 22603 GAINESBORO MAGISTERIAL DISTRICT DAVID L. FRANKLic. No.1061 STRM 3 TO 5.4 HORIZONTAL SCALE: 1" = 30' VERTICAL SCALE: 1" = 3' 758 760 765 770 775 780 785 790 795 800 758 760 770 780 790 800 9+50 10+00763.0775.311+00778.0778.812+00779.0779.413+00779.6778.614+00780.7779.8780.1415+00782.6778.98783.2782.8316+00NEW RIM ELEV=778.00EX 5 - EX. DI-1INV IN 767.00 (EX 5.1)INV OUT 766.80 ()12+85.77RIM=778.68EX 5.2 - EX. DI-1INV IN 769.58 (5.3)INV OUT 769.38 (EX 5.1)14+23.7373 LF 3 0 " H D P E @ 3.32%RIM=778.605.3 - DI-7INV IN 773.00 (5.4)INV OUT 772.00 (EX 5.2)14+96.6367 LF 30" RCP C L I I I @ 1.64% 71 LF 30" RCP C L I I I @ 1.52% 137 LF 30" RC P C L I I I @ 1 . 5 7 % 148 LF 30" RC P C L I I I @ 1 . 5 7 %RIM=777.28EX 5.1 - DI-1INV IN 768.28 (EX 5.2)INV OUT 768.08 (EX 5)13+56.76EX SWM POND EX. GRADE FIN. GRADE SSWR XING STA. 11+29.666" PVC INV=771.00WATR XING STA. 11+71.404" DIP INV=774.45WATR XING STA. 12+12.744" DIP INV=774.45WATR XING STA. 13+90.504" DIP INV=776.21APPROX WATR XING STA. 14+58.684" DIP INV=775.87STA:10+00.00 INV:762.31 87 LF 1 8" H D P E @ 4.07%RIM=778.505.4 - DI-1INV OUT 776.55 (5.3)15+83.93WATR XING STA. 15+19.204" DIP INV=778.65WATR XING STA. 15+28.472.5" DIP INV=778.8032" CLEAR31" CLEARSta=15+19.20TEST PIT REQUIREDSta=14+87.43TEST PIT REQUIREDSta=14+58.83TEST PIT REQUIREDSta=15+28.47TEST PIT REQUIREDCONTRACTOR SHALL TEST PIT AND VERIFY EX. UTILITY DEPTH AND CROSSING CLEARANCE 6A TO 6.1A HORIZONTAL SCALE: 1" = 30' VERTICAL SCALE: 1" = 3' 778 780 785 790 795 778 780 790 9+50 10+00785.7784.0011+00 34 LF 15" HDPE @ 0.89%6.1A - 15" FESINV 784.30 (6A)10+36.046A - 15" FESINV 784.00 (6.1A)10+02.38FIN. GRADE EX. GRADE STRM 10A TO 10.1A HORIZONTAL SCALE: 1" = 30' VERTICAL SCALE: 1" = 3' 768 770 775 780 785 768 770 780 9+50 10+00777.9776.4010+50 (4) 26 LF 1 2 " S D R - 3 5 @ 2.30% STA:10+00.00 INV:776.40 STA:10+26.12 INV:777.00 FIN. GRADE EX. GRADE WATR XING STA. 10+04.924" SDR-35 INV=773.66STRM 11A TO 11.1A HORIZONTAL SCALE: 1" = 30' VERTICAL SCALE: 1" = 3' 772 775 780 785 772 780 9+50 10+00779.7779.7010+50 (4) 18 LF 12" SDR-35 @ 1.65% STA:10+00.00 INV:777.70 STA:10+18.16 INV:778.00 FIN. GRADE EX. GRADE U:\Accounts\RRMMX\RRMMX21005 - Indian Hollow ES Renovation\DESIGN\_SHEETS\02-Design Development\CS6100 STORM PROFILES.dwg PLOTTED: 3/25/2022 2:07 PM, BY: Liliana Hernandez PLOTSTYLE: Pennoni NCS.stb PROJECT STATUS: CONSTRUCTION DRAWINGSBYNO.DATEREVISIONSRRMMX21005 AS NOTED CJM 2021-11-18 RAMAPPROVED BY DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM.ALL DIMENSIONS MUST BE VERIFIED BY CONTRACTORAND OWNER MUST BE NOTIFIED OF ANYDISCREPANCIES BEFORE PROCEEDING WITH WORK00 50'100' GRAPHIC SCALE 1"=50'PENNONI ASSOCIATES INC.117 East Piccadilly StreetWinchester, VA 22601T 540.667.2139F 540.665.0493100% CD PLAN SET 01/31/2022  03/25/2022 FREDERICK COUNTY PUBLIC SCHOOLSPO BOX 3508 | WINCHESTER, VA. 22604STORM PROFILESCS6100 TOTAL SHEETS 17INDIAN HOLLOW ELEMENTARY SCHOOLMINOR RENOVATIONS AND REPAIRSCONSTRUCTION DRAWINGS1548 NORTH HAYFIELD RD. | WINCHESTER, VA. 22603GAINESBORO MAGISTERIAL DISTRICTDAVID L. FRANK Lic. No.1061