Loading...
HomeMy WebLinkAbout01-21 Site PlanCLEAR BROOK VOLUNTEER FIRE & RESCUE, INC. BUILDING ADDITION SITE PLAN (SP #01-21) FREDERICK COUNTY, VIRGINIA LOCATION MAP: PROJECT INFORMATION:SHEET INDEX: PROJECT NOTES: SCALE: 1" = 1000' PROJECT LOCATION SHEET DESCRIPTION SHEET NUMBER COVER SHEET....................................................................................... GENERAL NOTES................................................................................... EXISTING CONDITIONS & DEMOLITION PLAN.................................... SITE PLAN............................................................................................... GRADING AND E&SC PLAN................................................................... LIGHTING PLAN...................................................................................... UTILITY PROFILES................................................................................. E&SC NOTES & DETAILS....................................................................... CONSTRUCTION DETAILS.................................................................... C-01 C-02 C-03 C-04 C-05 C-06 C-07 C-08 C-09 VA STATEGRID NORTHCURRENT OWNER: REFERENCE: PREVIOUS APPROVALS: USE DESCRIPTION: ACREAGE: ZONING: PHYSICAL ADDRESS: DISTURBED AREA: FLOODPLAIN: CLEAR BROOK VOLUNTEER FIRE CO. TM 33-A-149 STONEWALL MAGISTERIAL DISTRICT SP #09-89, BZA #13-16 VOLUNTEER FIRE STATION 5.00 AC. (DEEDED), 2.80 AC. (ACTUAL) RA 1256 BRUCETOWN ROAD 9,960 SQ. FT. (0.23 ACRES) OUTSIDE 100 YEAR FLOODPLAIN BASED ON FIRM MAP PANEL 51069C0250D, DATED SEPTEMBER 2, 2009 PROJECT CONTACTS: OWNER: ADDRESS- PHONE NUMBER- E-MAIL- CONTACT- ARCHITECT: ADDRESS- PHONE NUMBER- E-MAIL- CONTACT- ENGINEER (CIVIL): ADDRESS- PHONE NUMBER- E-MAIL- CONTACT- ENGINEER (MEP): ADDRESS- PHONE NUMBER- E-MAIL- CONTACT- CLEAR BROOK VOLUNTEER FIRE & RESCUE, INC. P.O. BOX 56 CLEAR BROOK, VA 22624 (540) 550-4770 WEBERS-WILL@COMCAST.NET WILL WEBER MAIN STREET ARCHITECTURE, PC 24 N. BUCKMARSH ST. BERRYVILLE, VA 22611 (540) 955-1669 KEN@MAINSTREETARCH.COM KEN LIVINGSTON DICE ENGINEERING, PLC 101 SHELBY CT. WINCHESTER, VA 22602 (540) 974-5157 DDUNLAP@DICE-ENG.COM DENNIE DUNLAP FHC ENGINEERING, PC 4 WEEMS LANE, SUITE 277 WINCHESTER, VA 22601 (540) 247-2939 AJOHNSTON@FHCPC.COM ALAN JOHNSTON ELECTRIC COMPANY: ADDRESS- PHONE NUMBER- CONTACT- WATER PROVIDER: ADDRESS- PHONE NUMBER- CONTACT- SEWER PROVIDER: ADDRESS- PHONE NUMBER- CONTACT- GAS COMPANY: ADDRESS- PHONE NUMBER- CONTACT- PHONE COMPANY: ADDRESS- PHONE NUMBER- CONTACT- RAPPAHANNOCK ELECTRIC CO-OP 137 KELLEY COURT FRONT ROYAL, VA 22630 (540) 622-5138 FREDERICK WATER P.O. BOX 1877 WINCHESTER, VA 22604 (540) 868-1061 FREDERICK WATER P.O. BOX 1877 WINCHESTER, VA 22604 (540) 868-1061 SHENANDOAH GAS 350 HILLANDALE LANE WINCHESTER, VA 22602 (540) 868-7925 VERIZON 404 HILLANDALE LANE WINCHESTER, VA 22602 (540) 665-3153 CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYCOVER SHEETC-01C-01.DWGDDDN/ADDDDESCRIPTION01-05-202102-23-2021 BRUCETOWN RD.RTE. 11JOB NO.: 20-11CLEAR BROOK VOLUNTEER FIRE & RESCUE, INC.FREDERICK COUNTY, VAFREDERICK COUNTY SP #01-21 RESPONSIBLE LAND DISTURBER NAME: CONTACT INFO: CERTIFICATION #: EXP. DATE: THE RESPONSIBLE LAND DISTURBER IS THE PARTY RESPONSIBLE FOR CARRYING OUT THE LAND DISTURBING ACTIVITY AS SET FORTH IN THE PLANS.1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS02-23-2021DDD CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYGENERAL NOTESC-02C-02.DWGDDDN/ADDDDESCRIPTION01-05-202102-23-2021 JOB NO.: 20-11 FREDERICK COUNTY SP #01-21CLEAR BROOK VOLUNTEER FIRE & RESCUE, INC.FREDERICK COUNTY, VA1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS02-23-2021DDD CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYEXISTING CONDITIONS& DEMOLITION PLANJOB NO.: 20-11 C-03C-03.DWGDDD1" = 20'DDDDESCRIPTION01-05-20211 inch = ft. ( IN FEET ) GRAPHIC SCALE 20 02-23-2021 FREDERICK COUNTY SP #01-21 (T.B.R.) (T.B.R.) (SEE NOTES #1 & #2) (SEE NOTE #5) (SEE NOTES #1 & #2) (SEE NOTE #3) (T.B.R.) (SEE NOTE #4) NOTES: 1.EXISTING SEPTIC TANK SHALL BE REMOVED AND EXISTING SANITARY DRAINFIELD TO BE CLOSED IN ACCORDANCE WITH FREDERICK COUNTY HEALTH DEPT. REGULATIONS. 2.EXISTING SANITARY SEPTIC SYSTEM AS INDICATED IS APPROXIMATE, AND SHALL BE FIELD VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION. 3.EXISTING SANITARY LATERAL TO BE CUT 5' FROM FACE OF BUILDING. THIS LATERAL WILL BE REROUTED TO THE NEW SANITARY PUMP STATION (REFER TO SHEET C-04). 4.EXISTING WELL TO BE CLOSED IN ACCORDANCE WITH FREDERICK COUNTY HEALTH DEPT. REGULATIONS. 5.EXISTING PROPANE TANK TO BE RELOCATED (REFER TO SHEET C-04).CLEAR BROOK VOLUNTEER FIRE & RESCUE, INC.FREDERICK COUNTY, VA1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS02-23-2021DDD FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYSITE PLANJOB NO.: 20-11 C-04C-04.DWGDDD1" = 10'DDDDESCRIPTION01-05-20211 inch = ft. ( IN FEET ) GRAPHIC SCALE 10 02-23-2021 CLEAR BROOK VOLUNTEER FIRE CO.FREDERICK COUNTY, VAFREDERICK COUNTY SP #01-21 RELOCATED ABOVE-GROUND PROPANE STORAGE TANK 4' CONC. S/W R.D. PROPOSED 2492 SQ. FT. BUILDING ADDITION 80.00 LF - 6" PVC ROOF DRAIN @ 0.50% R.D. R.D. R.D.R.D. R.D. R.D. 80.00 LF - 6" PVC ROOF DRAIN @ 0.50%5' CONC. S/W 5' 4' 10.2' 3' 3' 3' 4' CONC. PATIO C.O. #3 1" CTS POLYETHYLENE TUBING (PET) 200 PSI W/L (PRIVATE) (MAINTAIN MIN. COVER OF 48") CONNECTION TO EX. DOMESTIC W/L (BY CONTRACTOR) C.O. #1 4" x 4" x 4" WYE C.O. #2 45° BEND 90.34 LF - 4" PVC SDR 35/26 SAN. SEW. LATERAL @ 2.00% (MIN.) -- (PRIVATE) (MAINTAIN MIN. COVER OF 36") 39.98 LF - 4" PVC SDR 35/26 SAN. SEW. LATERAL @ 2.00% (MIN.) -- (PRIVATE) ADA ACCESS SANITARY PUMP STATION (PRIVATE) E-ONE (DH071-93) TOP = 627.50 INV. IN = 622.68 (4") INV. OUT = 623.26 (1.5") BOTTOM = 619.85 1.5" CTS POLYETHYLENE TUBING (PET) 200 PSI SANITARY FORCEMAIN (PRIVATE) (MAINTAIN MIN. COVER OF 48") (SEE NOTE #1, THIS SHEET) NOTES: 1.REFER TO OFF-SITE SEWAGE DISPOSAL DESIGN PLANS BY GREENWAY ENGINEERING, INC., DATED SEPTEMBER 2016, FOR CONTINUATION OF PROPOSED SANITARY FORCEMAIN ALIGNMENT AND DETAILS. 2.PLACE LANDSCAPE STONE AT DEPTH OF 4" OVER WEED-STOP FABRIC IN STRIP BETWEEN SIDEWALK AND FACE OF BUILDING. 3.FIRE LANE SIGNAGE AND MARKINGS TO CONFORM TO THE FREDERICK COUNTY FIRE PREVENTION CODE APPENDIX D FIRE APPARATUS ACCESS ROADS D103.6 SIGNS, AND BE PLACED IN ACCORDANCE WITH THE FIRE MARSHAL'S OFFICE. EDGE OF PAVEMENT AT FIRE LANE SIGNS SHALL BE MARKED WITH A SOLID 6" WIDE YELLOW LINE TO DELINEATE EXTENTS OF FIRE LANE. HVAC UNITS (2)1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS02-23-2021DDDFIRE LANE MARKING (LENGTH = 33') (SEE NOTE #3, THIS SHEET) FIRE LANE SIGN (TYPE 'D') (SEE DETAIL, SHEET C-09) 628 629629628 OP OP FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SFSFSFSFSFSF SFSFSF SFSFSF SF SFSFSF SF SF SF SF SF SF SF SF SF SF SFSFSFSFSFSFSFSFSF SF SF SF SF SF SF 628 629629628 OP OP FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SFSFSFSFSFSF SFSFSF SFSFSF SF SFSFSF SF SF SF SF SF SF SF SF SF SF SFSFSFSFSFSFSFSFSF SF SF SF SF SF SF CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYGRADING AND E&SC PLANJOB NO.: 20-11 C-05C-05.DWGDDD1" = 10'DDDDESCRIPTION01-05-20211 inch = ft. ( IN FEET ) GRAPHIC SCALE 10 02-23-2021 CLEAR BROOK VOLUNTEER FIRE CO.FREDERICK COUNTY, VAFREDERICK COUNTY SP #01-21 PROPOSED 2492 SQ. FT. BUILDING ADDITION F.F. = 629.46 ± (MATCH EX.) SANITARY PUMP STATION (PRIVATE) E-ONE (DH071-93) TOP = 627.50 INV. IN = 622.68 (4") INV. OUT = 623.26 (1.5") BOTTOM = 619.85 C.O. #1 TOP = 628.35 629.30629.24 629.35 629.30 629.25 629.20 629.25 629.20 629.30 629.30 629.30 629.30 629.30 (FLUSH W/ PAVEMENT) 629.25 (FLUSH W/ PAVEMENT) 629.30 629.25629.25 629.20 629.25 629.25 629.25 INV. = 627.30 INV. = 627.40 C.O. #3 TOP = 629.00 C.O. #2 TOP = 629.25 LEGEND NO.TITLE KEY SYMBOL - LIMITS OF DISTURBANCE 3.27 SUPER SILT FENCE SF SF OP SIZING: W = 2' L = 4' d50 = 6" OP SIZING: W = 2' L = 4' d50 = 6" TEMPORARY TOPSOIL STOCKPILE 629.25 1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS02-23-2021DDD XSPW-2ME MH: 7 .1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1XSPW-4ME MH: 8.5 .1 .1 .1 .1 .1 .1 .1 .1.1 .1.1 .1 .1 .1 .1 .1 .1 .1 .1 .1 .1 XSPW-4ME MH: 8.5 .1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1XSPW-2ME MH: 8.5.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.1.10.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.4 0.7 0.3 0.3 0.6 0.6 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.5 2.4 6.6 17.0 5.3 1.6 0.4 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.3 0.9 1.1 0.7 1.1 0.9 0.3 0.1 0.0 0.0 0.0 0.1 0.4 2.7 4.5 3.3 4.4 2.6 0.4 0.1 0.0 0.0 0.0 0.1 0.4 2.5 5.1 5.2 4.9 2.5 0.4 0.1 0.0 0.0 0.0 0.1 0.4 2.1 3.1 3.0 2.0 0.4 0.1 0.0 0.0 0.0 0.1 0.3 0.6 1.4 3.7 8.1 6.1 2.3 0.0 0.0 0.3 0.3 0.2 0.1 0.0 0.0 0.0 0.1 0.2 0.5 1.6 2.9 5.2 4.1 2.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.0 CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYLIGHTING PLANJOB NO.: 20-11 C-06C-06.DWGDDD1" = 10'DDDDESCRIPTION01-05-20211 inch = ft. ( IN FEET ) GRAPHIC SCALE 10 02-23-2021 FREDERICK COUNTY SP #01-21 PROPOSED BUILDING ADDITION Luminaire Schedule Symbol Qty Label Arrangement LMF Lum. Lumens Lum. Watts Part Number 2 XSPW-4ME SINGLE 0.960 4270 31 XSPW-B-WM-4ME-4L-40K-UL-BZ 2 XSPW-2ME SINGLE 0.960 4270 31 XSPW-B-WM-2ME-4L-40K-UL-BZ Calculation Summary (Footcandles calculated using predicted lumen values @ 50K hrs of operation) and 10°C ambient Label Units Avg Max Min Avg/Min Max/Min Grade Fc 0.87 17.0 0.0 N.A.N.A. Property Line Fc 0.00 0.0 0.0 N.A.N.A. NOTES: 1.LIGHTING DESIGN BY CREE LIGHTING. 2.ALL PROPOSED BUILDING-MOUNTED LIGHTING FIXTURES SHALL BE SHIELDED, FULLY DOWNCAST, AND FULL-CUTOFF. ALL LIGHTING SHALL CONFORM TO THE REQUIREMENTS IN THE FREDERICK COUNTY ZONING ORDINANCE SECTION 165-201.07.CLEAR BROOK VOLUNTEER FIRE & RESCUE, INC.FREDERICK COUNTY, VA1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS02-23-2021DDD 615 620 625 630 635 615 620 625 630 635 10+00 11+00 11+50 615 620 625 630 635 615 620 625 630 635 10+00 11+00 615 620 625 630 635 615 620 625 630 635 10+00 10+50STA. 10+29.936" STM X-INGINV. = 627.4648" MIN. COVER STA. 11+22.751" x 1" x 1" TEEPROPOSED GRADE 1" CTS PET W/L (200 PSI - PRIVATE) 18" MIN. CLEAR (TYP.)STA. 10+00.00BLDG. CONN.STA. 10+90.34C.O. #2 @ 45° BEND (CONN. TO EX.)TOP = 629.25INV. = 625.3936" MIN. COVERSTA. 10+00.00PUMP STATION (PRIVATE)E/ONE DH071-93TOP = 627.50DISCHARGE = 623.26 (1.5")INV. IN = 622.68 (4")BOTTOM = 619.85STA. 10+42.30C.O. #1 @ 4" x 4" x 4" WYETOP = 628.35INV. = 623.9590.34LF - 4" SDR 35/26 PVC SAN. SEW. @ 3.00% (SEE NOTE #1)STA. 10+81.336" STM X-INGINV. = 627.4318" MIN. CLEAR (TYP.)STA. 10+39.98BLDG. CONN.INV. = 625.15STA. 10+00.00C.O. #1 @ 4" x 4" x 4" WYETOP = 628.35INV. = 623.95PROPOSED GRADE 39.98LF - 4" SDR 35/26 PVC SAN. SEW. @ 3.00% (SEE NOTE #1) 36" MIN. COVERSTA. 10+29.98C.O. #3TOP = 629.00INV. = 624.851.5" CTS PET 200 PSI SANITARY FORCEMAIN (PRIVATE) (MAINTAIN MIN. COVER OF 48") (SEE NOTE #2) 10+00 11+00 11+23628 629629628 10+0010+90628 629628 FM FM FM FM 10+00 10+40 628 629628 FM FM FM CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYUTILITY PROFILESC-07C-07.DWGDDDDDDDESCRIPTION01-05-2021AS SHOWN02-23-2021 CLEAR BROOK VOLUNTEER FIRE CO.FREDERICK COUNTY, VAJOB NO.: 20-11 FREDERICK COUNTY SP #01-21WATERLINE (DOMESTIC -- PRIVATE)SANITARY (PS - CO #2 -- PRIVATE)SANITARY (CO #1 - CO #3 -- PRIVATE)WWWWW W W W W W W W STA. 10+00.00 E/ONE DH071-93 PUMP STATION (PRIVATE) C.O. #1 STA. 10+90.34 C.O. #2 @ 45° BEND CONN. TO EX. LATERAL STA. 10+00.00 C.O. #1 C.O. #3 STA. 10+39.98 BLDG. CONN. STA. 10+00.00 BLDG. CONN. STA. 11+22.75 1" x 1" x 1" TEE 1" CTS PET W/L (200 PSI - PRIVATE) 4" SDR 35/26 PVC SAN. SEW. 4" SDR 35/26 PVC SAN. SEW. NOTES: 1.THE ELEVATION OF THE EXISTING SANITARY LATERAL LEAVING THE EXISTING BUILDING IS UNKNOWN. CONTRACTOR SHALL CONNECT TO THIS EXISTING LATERAL WITH A 45° BEND AND CLEANOUT AS INDICATED. SINCE THE PIPE INVERT ELEVATION AT THIS CONNECTION POINT IS NOT KNOWN, THE SLOPE OF THE PROPOSED SANITARY LATERAL SHALL BE ADJUSTED AS NECESSARY TO THE FIELD VERIFIED ELEVATIONS. 2.REFER TO OFF-SITE SEWAGE DISPOSAL DESIGN PLANS BY GREENWAY ENGINEERING, INC., DATED SEPTEMBER 2016, FOR CONTINUATION OF PROPOSED SANITARY FORCEMAIN ALIGNMENT AND DETAILS. EX. 5/8" W.M. 1.5" CTS PET 200 PSI SANITARY FORCEMAIN (PRIVATE) (MAINTAIN MIN. COVER OF 48") (SEE NOTE #2)1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS02-23-2021DDD EROSION CONTROL NOTES:SEEDING SPECIFICATIONS TEMPORARY CONTROL MEASURES: TEMPORARY SOIL EROSION AND SEDIMENT CONTROL MEASURES WILL BE INSTALLED PRIOR TO ANY MAJOR SOIL DISTURBANCE IN ORDER TO PREVENT ACCELERATED EROSION AND TRANSPORTATION OF SEDIMENT DURING SITE DISTURBANCE. SILT FENCE WILL BE USED TO LIMIT SEDIMENTATION FROM SMALL UPHILL AREAS. ANY DISTURBED AREAS THAT WILL BE LEFT EXPOSED MORE THAN 7 DAYS, AND NOT SUBJECT TO CONSTRUCTION TRAFFIC WILL IMMEDIATELY RECEIVE TEMPORARY SEEDING AND MULCH. IF THE SEASON PREVENTS ESTABLISHMENT OF TEMPORARY COVER, THE DISTURBED AREAS WILL BE MULCHED WITH STRAW, OR EQUIVALENT MATERIAL AT A RATE OF 2.0 TONS PER ACRE. ALL CRITICAL AREAS (I.E. STEEP SLOPES AND ROADWAY EMBANKMENTS) WILL RECEIVE A TEMPORARY SEEDING IMMEDIATELY FOLLOWING THE ESTABLISHMENT OF FINAL GRADE IN COMBINATION WITH STRAW OR MULCH, OR A SUITABLE EQUIVALENT AT A RATE OF 2.0 TONS PER ACRE. THE DESIGN OF THE PROJECT INTENDS TO DISTURB AS LITTLE OF THE SITE AS POSSIBLE. SEED: FALL - RYE, TWO ½ BUSHELS PER ACRE [SEPTEMBER 1 - NOVEMBER 15] SPRING - OATS, TWO ½ BUSHELS PER ACRE [MARCH 1 - MAY 15] MULCH: 2.0 TONS PER ACRE MULCH BINDER: EMULSIFIED ASPHALT SS-1 AT THE RATE OF 150 GALLONS PER ACRE FERTILIZER: 3 TON DOLOMITIC LIMESTONE/ACRE; 600 LBS.; 10-10-10/ACRE PERMANENT CONTROL MEASURES: PERMANENT CONTROL MEASURES WILL BE INSTALLED IN THEIR PROPER SEQUENCE THROUGHOUT THE CONSTRUCTION PERIOD. THESE MEASURES WILL PREVENT EROSION ONCE CONSTRUCTION ACTIVITY IS COMPLETE. PERMANENT CONTROL MEASURES FOR THIS PROJECT INCLUDE THE ESTABLISHMENT OF PERMANENT COVER AND INSTALLATION OF RIP-RAP APRONS AT STORM PIPE OUTLETS. ALL AREAS SHALL BE PERMANENTLY SEEDED AND MULCHED WITHIN ONE WEEK OF REACHING FINAL GRADE, OTHERWISE TEMPORARY REQUIREMENTS SHALL BE MET. ADDITIONALLY, ALL AREAS SHALL BE SEEDED AND MULCHED WITHIN 7 DAYS IF THE AREA IS TO REMAIN UNWORKED FOR A PERIOD OF 14 DAYS OR MORE. DURING THE FIRST GROWING SEASON AFTER REACHING FINAL GRADE, A PERMANENT SEED MIXTURE WILL BE ADDED. ANY SOIL THAT WILL NOT PROVIDE A SUITABLE ENVIRONMENT TO SUPPORT ADEQUATE VEGETATIVE GROUND COVER, SHALL BE REMOVED OR TREATED IN SUCH A WAY THAT WILL PERMANENTLY ADJUST THE SOIL CONDITIONS AND RENDER IT SUITABLE FOR VEGETATIVE GROUND COVER. IF THE REMOVAL OR TREATMENT OF THE SOIL WILL NOT PROVIDE SUITABLE CONDITIONS, NON-VEGETATIVE MEANS OF PERMANENT GROUND STABILIZATION WILL HAVE TO BE EMPLOYED. ALL ROADWAY SLOPES AND DISTURBED AREAS ARE TO BE SEEDED AND MULCHED. GROUND IS TO BE DISCED TO A DEPTH OF SIX (6) INCHES AND SEEDED AS SOON AS POSSIBLE AFTER GROUND HAS BEEN DISTURBED. 10-20-10 FERTILIZER IS TO BE APPLIED AT THE RATE OF 1000 LBS PER ACRE AND LIME AT THREE TONS PER ACRE PRIOR TO DISCING. MULCHING IS TO BE 2.0 TONS OF STRAW WITH 100 GALLONS OF TAR MIXED PER ACRE. ALL WORK SHALL BE DONE IN ACCORDANCE WITH SOIL CONSERVATION SERVICE STANDARDS. PERMANENT SEEDING (MARCH 1 -SEPT. 1 ) WILL BE APPLIED AS FOLLOWS: SEED: 150 LBS/ACRE KENTUCKY 31 - 90% RED TOP GRASS - 5% WHITE CLOVER - 5% FERTILIZER: 2 TONS DOLOMITIC LIMESTONE/ACRE; 1000 LBS/ACRE OF 10/20/10 MULCH: 2.0 TONS/ACRE OF STRAW CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYE&SC NOTES AND DETAILSC-08C-08.DWGDDDN/ADDD1.THE CONTRACTOR SHALL ARRANGE FOR A PRE-CONSTRUCTION CONFERENCE WITH THE FREDERICK COUNTY EROSION AND SEDIMENT CONTROL DIRECTOR 48 HOURS PRIOR TO BEGINNING WORK. 2.ALL EROSION CONTROL DEVICES AS SHOWN OR AS REQUIRED ARE TO BE CONSTRUCTED TO STANDARDS AND SPECIFICATIONS OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK (LATEST EDITION) AND ARE TO BE IN PLACE PRIOR TO ALL CONSTRUCTION. 3.THIS PLAN IS NOT COMPLETE WITHOUT THE APPROVED NARRATIVE. 4.EROSION AND SEDIMENT CONTROL MEASURES SHALL BE MAINTAINED CONTINUOUSLY, RELOCATED WHEN AND AS NECESSARY AND SHALL BE CHECKED AFTER EVERY RAINFALL. SEEDED AREAS SHALL BE CHECKED REGULARLY AND SHALL BE WATERED, FERTILIZED, RESEEDED AND MULCHED AS NECESSARY TO OBTAIN A DENSE STAND OF GRASS. 5.ALL DISTURBED AREAS NOT PAVED OR BUILT UPON ARE TO BE FERTILIZED, SEEDED, AND MULCHED BY THE CONTRACTOR IN ACCORDANCE WITH THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK (LATEST EDITION). 6.ALL DRAIN INLETS SHALL BE PROTECTED FROM SILTATION. INEFFECTIVE PROTECTION DEVICES SHALL BE IMMEDIATELY REPLACED AND THE INLET CLEANED. FLUSHING IS NOT AN ACCEPTABLE METHOD OF CLEANING. 7.GRADE AREAS ADJACENT TO BUILDING TO ACHIEVE DRAINAGE AWAY FROM THE STRUCTURE AND TO PREVENT PONDING IN SWALES. 8.PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN SEVEN DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN DORMANT (UNDISTURBED) FOR LONGER THAN 14 DAYS. 9.DURING CONSTRUCTION OF THE PROJECT, SOIL STOCKPILES SHALL BE STABILIZED OR PROTECTED WITH SEDIMENT TRAPPING MEASURES. 10.VEGETATIVE STABILIZATION SHALL BE UNIFORM AND MATURE ENOUGH TO SURVIVE AND ADEQUATE TO INHIBIT EROSION. 11.SEDIMENT BASINS AND TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS AND OTHER MEASURES INTENDED TO TRAP SEDIMENT SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND- DISTURBING ACTIVITY AND SHALL BE MADE FUNCTIONAL BEFORE UPSLOPE LAND DISTURBANCE TAKES PLACE. 12.STABILIZATION MEASURES SHALL BE APPLIED TO EARTHEN STRUCTURES SUCH AS DAMS, DIKES AND DIVERSIONS IMMEDIATELY AFTER INSTALLATION. 13.UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TO OTHER APPLICABLE CRITERIA: A.NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME. B.EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES. C.EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVED SEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER THAT DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFF-SITE PROPERTY. D.MATERIAL USED FOR BACK FILLING TRENCHES SHALL BE PROPERLY COMPACTED IN ORDER TO MINIMIZE EROSION AND PROMOTE STABILIZATION. E.RESTABILIZATION SHALL BE ACCOMPANIED IN ACCORDANCE WITH THESE REGULATIONS. F.APPLICABLE SAFETY REGULATIONS SHALL BE COMPLIED WITH. 14.WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED PUBLIC ROADS, PROVISIONS SHALL BE MADE TO MINIMIZE THE TRANSPORT OF SEDIMENT BY VEHICULAR TRACKING ONTO THE PAVED SURFACE. WHERE SEDIMENT IS TRANSPORTED ONTO A PUBLIC ROAD SURFACE, THE ROAD SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM THE ROADS BY SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. 15.ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, UNLESS OTHERWISE AUTHORIZED BY THE LOCAL PROGRAM ADMINISTRATOR. TRAPPED SEDIMENT AND THE DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES SHALL BE PERMANENTLY STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION. 16.ALL DISTURBED AREAS NOT PAVED OR BUILT UPON SHALL BE TOP SEEDED, MULCHED AND FERTILIZED. PERFORM PERMANENT TOP SOILING, SEEDING, LANDSCAPING, FERTILIZING, AND MULCHING AS SOON AFTER FINISH GRADING AS POSSIBLE. SEEDING SHALL COMPLY WITH THE FOLLOWING: A.TOPSOIL - 4 INCH MINIMUM FOR PERMANENT TURF B.FERTILIZER - 450 POUNDS PER ACRES OF 10-20-10 FERTILIZER OR EQUIVALENT POUNDAGE OF DIFFERENT ANALYSIS. WORK INTO SOIL PRIOR TO SEEDING. C.LIME (PERMANENT SEEDING) - AGRICULTURAL LIME SPREAD AT RATE OF 2 TONS/ACRE. WORK INTO SOIL PRIOR TO SEEDING. D.MULCH-CHOPPED STRAW AT RATE OF 2 TON PER ACRE AND TACKED IN PLACE. HYDRO-MULCH AT RATE OF 30 BALES PER ACRE.DESCRIPTION01-05-202102-23-2021 JOB NO.: 20-11 FREDERICK COUNTY SP #01-21 DUST CONTROL MEASURES CLEAR BROOK VOLUNTEER FIRE & RESCUE, INC.FREDERICK COUNTY, VA1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS02-23-2021DDD CADD FILE:DATE:REV. #SCALE:DATE101 SHELBY CT.WINCHESTER, VA 22602PHONE: 540.974.5157FAX: 540.723.4868EMAIL: OFFICE@DICE-ENG.COMSHEET NUMBER:DRAWN BY:CHECKED BY:BYCONSTRUCTION DETAILSC-09C-09.DWGDDDN/ADDDDESCRIPTION01-05-202102-23-2021 JOB NO.: 20-11 FREDERICK COUNTY SP #01-21 CONCRETE SIDEWALK DETAIL CLEAR BROOK VOLUNTEER FIRE & RESCUE, INC.FREDERICK COUNTY, VA1REVISIONS PER FREDERICK COUNTY AGENCY COMMENTS02-23-2021DDDFIRE LANE SIGN DETAILS