Loading...
HomeMy WebLinkAbout02-20 Site AcquisitionISSUED DATE_ _ SITE ACQUISITION 5/31/2018 REQUEST• ' MENS APPROM DAF t J ISSUED BY _ Gaurav Behl _ TRIDENT APPROVAL DATE APPROVED BY Sandeep Gupta PEFORMANCE MANAGER Andres Gomez SITE ACQUIS71ON COMPANY Smartlink DESIGN MANAGER Sandeep Gupta SITE ID (COMMON ID) 4124 _ DESIGN ENGINEER Gaurav Behl SEARCH RING ID �EGION _ IMARKETCLUSTER MARKET_ SUBMARKET `_ 4124 No Washington DC/ Maryland SEARCH RING NAME FROG EYE SIRBAUGH 2 GORE Frederick LOCATION COIN_MON NAME E911 PHASE CITY COUNTY i� _ (POLYGON CLUSTER SITE PRIORITY 1 -High CASPR PROJECT 41 _ FREQUENCY BAND 850/1900/700/AWS F7 D ASSET # _ 10138153 _ TECHNOLOGY LTE S CT OBJECTIVE -� B -COV ER= C l PASTE/INSERT SEARCH SEARCH RING RING MAP HERE PARAMETERS LOCATION SHORT DESCRiNi-ON_ Route 50 and SR 733 LATITUDE (N) (DD-MM-SS.S)� 39-17-4 LATITUDE DECIMAL (N) 39.284485 LONGITUDE (W) (DDD-MM-SS.S)� 78-23-5 LONGITUDE DECIMAL (W) -78.384773 GROUND ELEVATION AMSL (FEET) 1120 SEARCH RING RADIUS (miles) 0.7 UIRED HEIGHT - MAX AGL (FEET) 180 (FEET) _ OVERALL TOTAL HEIGHT -MAX AMS'L 1320 ., �REQUIIREDHEIGHT- MIN AGL (FEET) 200 (FEET) COVERAGEOBJECTIVE OVERALL TOTAL HEIGHT - MIN AMSI.� 1300 extend coverage in Freerick County along Route 50, SR 733 , 707, 610 and 703 there an available Crown or ATC. candidate within i.5 times the radius of the center of the search ring? If yes, include in rssible candidate 1 _ rssible candidate 2 _ rssible candidate 3 ."e candidate 4 iscandidate .i _ submit candidates within the red polygon shown above INFINIGY8 FROM ZERO TO INFINIGY the solutions are endless 6865 Deerpath Road, Suite 152, Elkridge, MD 21075 10/1/19 RE: AT&T Site Name: Frog Eye_ _ AT&T FA #: 10138153 Site Address: 141 Fairview Road Gore, VA 22637 To Whom It May Concern, This letter is written to address the proposed AT&T cell site installation located at 141 Fairview Road, Gore, VA 22637. The proposed cell site structure will be ordered by AT&T to be designed to adhere to TIA-222-G-2005 Structural Standards for antenna supporting structures and antennas. In addition, the structure will adhere to the International Building Code 2012 as amended and adopted by the Virginia Uniform Statewide Building code and all other local, state, and federal codes and requirements. Infinigy will confirm the order as requiring these codes to be met with final structure design and code adherence by tower manufacturer. The proposed tower structure which is proposed to measure 193' above ground level to top of steel and 199' above ground level to the lightning rod tip height. The tower will be designed with a critical design point located at the midpoint of the tower, 100' above grade level. This would be accomplished by ensuring an appropriate overdesign within the base 100' of the tower. This critical design point effectively increases the structural integrity of the design, and shall a tower failure occur, the critical design point would eb the point at which the tower would fail, thus reducing the fall zone in half, or 100'. Should you have any questions on the above, please do not hesitate to reach out to me directly at (518) 690-0790. Respectfully Submitted, Joe Johnston, PE Infinigy I INFINIGY8 vv ♦ �. JOSPs Lic. No. 53459 4a4 ,o 0 `S ONAL �'0 00+4440*