HomeMy WebLinkAbout03-20 Comments7' CEIVE
REQUEST FOR SITE PLAN COMMENTS JAN 3 0 2020
sit, rr-r...', C4'
rctnn—sp— IurFrederick County Insp os
Department Comment
Mail to:
Frg,derick County Inspections Department
Attn: Building Official
107 North Kent Street
Winchester, Virginia 22601
Hand deliver to:
Frederick County Inspections Dept.
107 North Kent Street, 2nd Floor
Winchester, Virginia 22601
Phone: (540) 665-5650
Applicant: It is your responsibility to complete this form as accurately as possible in order to assist the agency with their
review. Please attach two M conies of the Site Plan with this sheet
Y LN Zh t j .a _
ib.
161
r•
Applicant's Name: Painter -Lewis, P.L.C. Telephone: 5450-662-5792
Email Address: iciewis@painteriewis.com
Mailing Address: 817 Cedar Creek Grade, Suite 120
Winchester, VA 22601
Name of development and description of the request:
Airport Business Parc Building E Site Plan Revision
Location of Property:
190 Admiral Byrd Drive, Winchester, VA
Department Comments:
I-FREDERICK COUNTY INSPECTIONS DEPARTMENT USE ONLY- Date Received -3d- zm p Review Number 1 2 3 4 5
Date Reviewed "-7-A-2.0-40(circle one)
Revision Required 1y,Date pproved 2•,3-ZOZa
1111 Signature & Date:zo
PleaseRelu E tip can s l a'
l8av 2-3
Buildings shall comply with The Virginia Uniform Statewide Building Code (VUSBC) Sections
311, S Storage of the International Building Code/2015, the 2015 VUSBC/ International Fire
Code. Other Code that applies is ICC Al 17.1-3-09. Accessible and Usable Buildings and
Facilities and 2015 Virginia Energy Code
Proposed 88,233sq ft building shall meet T503 for height and area. Unlimited Area Buildings
per Section 507 shall maintain an open perimeter of 60'. Buildings have sprinkler systems
identified.
Maximum travel distance per IBC/USBC to an exit is 400'. All required exits shall meet ANSI
Al 17.1-09 for accessibility and slopes. Question on location of exterior exits along loading
loading dock area. All required exits shall be accessible. Exterior area of refuge shall
comply with Section 1016 of the USBC/IBC. Building wall for 10' in all directions shall be
rated for one hour. Openings located within the wall inside this 10' shall be rated as well.
The area of refuge shall be located outside the required dimensions of the landing. Minimum
48" between handrails required.
Maximum travel distance to restrooms shall be in accordance with Section 2902.3.2. (Maximum
500' unless otherwise approved by AHJ)
Storage racks exceeding 12' in height require fire department access around perimeter of the
building and shall comply with the 2012 Virginia Fire Code/International Fire Code. The access
doors shall not be spaced further apart than 100'
ANSI parking spaces provided as required per T1106.1 with a minimum of 4 spaces. Accessible
parking and unloading shall not exceed 2% slope (1:48). Accessible Route shall extend from
parking and unloading area to accessible route to main entrance. Curb ramps shall have a
minimum 3' landing at the top and bottom of the landing. Van spaces require minimum
unloading area 8' with 8' of parking or a minimum of 11' wide parking with 5' of unloading
space is required. No enlargement provided. Accessible route with max 5% slopes shall be
provided from parking/unloading to main entrance.
Public entrances into spaces larger than 3000 sq ft shall be provided with a vestibule as detailed
per ANSI A 117.1-09
All structural plans submitted for permit application shall be sealed by a VA Design Professional
Special inspection requirements of Chapter 17 of IBC shall apply to this type of structure. (soils,
compaction, concrete, steel etc.) Geotech report is required per Uniform Statewide Building
Code, Section 1803
1/15/19 exterior area of refuge provided at rear doors.
2/3/2020 No additional comments
storage, airport business e
REQUEST FOR SITE PLAN CO1V WNTS
Frederick Count, sire Marshal Comment
Mail to: Hand deliver to:
Frederick County Fire Marshal Public Safety Building
Attn: Fire Marshal 1080 Coverstone Drive
1080 Coverstone Drive Winchester, Virginia 22602
Winchester, Virginia 22602 Phone: (540) 665-6350
Applicant: It is your responsibility to complete this form as accurately as
review. Please attach two t2�f,ies of the Site Plan with this sheet passible in order to assist the agency with their
Applicant's Name: Painter -Lewis, P.L.C. _
Email Address: iclewis@painterlewis.com
Mailing Address: 817 Cedar Creek Grade, suite 120
Winchester, VA 226171
Name of development and description of the request:
Airport Business Parc Building E Site Plan Revision
Location of Property:
190 Admiral Byrd Drive, Winchester, VA
Fire Marshal Comments:
Telephone: 5450-662-5792
-FREDERICK COUNTY FIRE MARSHAL USI; ONLY -
Date. Received Review Number 1 2 3 4 5 (circle one)
Date Reviewed — — � o;�c
Revision Required Date Approved
f Signature & Date:
** Please Return form to Applicant**
!�=::Ell SATE
� 9
25
Frederick County Fire and Rescue Department
Office of the Fire Marshal
1080 Coverstone Drive
Winchester, VA 22602
Phone: 540-665-6350 Fax: 540-678-4739
fmo@fcva.us
Plan Review
Site
Business Flame
Airport Business Parc Building E
190 Admiral Byrd Dr
Winchester, Virginia 22602
Engineering Firm:
Painter -Lewis, PLC
Received Date: 01/30/2020
Review Begin Date: 02/04/2020
Review End Date: 02/05/2020
Hours: - 2.0000
Occupancy Type:
Property Use:
Activity Number:
Review Cause:
Details
Project Name New Construction
Comments:
Approved. Any revisions shall be submitted for approval.
Adam Hounshell
Lieutenant/Assistant Fire Marshal
Status: Approved
Printed Date: 02/05/2020
IO I BJ060
New Construction
Page 1 of 1
John Lewis (�
From: Earl Wiley <ewiley@frederickwater.com>
Sent: Friday, February 21, 2020 10:39 AM
To: John Lewis
Cc: Michael Newlin
Subject: Pruitt Building E
John,
We discussed the minor plan revision you dropped off earlier in the week and the hp protectus 3 fire meter would be
required. Please make the changes below;
1. Add to the plans; 'Interior HP Protectus 3 meter and double detector check [, double detector check and
interior 1.5" domestic water meter ] shall be installed per Frederick Water inspector's requirements'. If your
client wants to use an interior domestic water meter in lieu of the exterior water meter, use the wording in
brackets above.
2. For the wet tap with fire hydrant by Frederick Water, change to ' wet tap by Frederick Water' 'Fire hydrant by
contractor'
3. Update the Frederick Water construction notes e, 0-r (.,
The revised site plan is approved as noted above. Please send me one set of final sheets, cd's; one pdf and one dwg.
Thanks,
Earl W. Wiley
Engineering Assistant
540.868.0294
Frederick Water
Physical Address: 315 Tasker Road, Stephens City VA 22655
Mailing Address: P.O. Box 1877, Winchester VA 22604
Website: www.frederickwater.com
I
February 26, 2020
Mr. John Lewis, PE
Painter -Lewis, P.L.C.
817 Cedar Creek Grade
Suite 120
Winchester, Virginia 22601
RE: Revised Site Plan Comments — Airport Business Park Building E
Dear Mr. Lewis:
COUNTY of FREDERICK
Department of Public Works
540/665-5643
FAX: 540/678-0682
Upon review of the revised site plan dated February 18, 2020, we recommend approval of
the subject plan.
Joseph W. Johnson, P.E.
Civil Engineer
JC W/kco
cc: Planning and Development
file
Sincerely,
/r 1
Joe C. Wilder
Director of Public Works