HomeMy WebLinkAbout26-19 Site Plan1
CO
V
E
R
S
H
E
E
T
1" = 1000'
GRAYSTONE INDUSTRIAL CENTER PHASE I
SITE DEVELOPMENT PLAN
STONEWALL MAGISTERIAL DISTRICT
FREDERICK COUNTY, VIRGINIA
SP# 26-19
Gas:Shenandoah Gas Co.
P.O. Box 2400
Winchester, VA 22604
(540) 869-1111
Phone:Verizon
P.O. Box 17398
Baltimore, MD 21297
(301) 954-6282
Water/Sewer: Frederick Water
P.O. Box 1877
Winchester, VA. 22604
(540) 868-1061
Power:Rappahannock Electric Coop
137 Kelly Court
Front Royal, VA 22630
1-800-552-3904
UTILITY NOTICE REQUIRED
Contractors shall notify all public utility operators who maintain underground utility lines in the
area of proposed excavating or blasting at least two (2) working days, but not more than ten (10)
working days, prior to commencement of excavation or demolition. Names and telephone
numbers of the operators of underground utility lines appear below. These numbers shall also be
used to serve in an emergency condition.
CALL "MISS UTILITY"
VIRGINIA UTILITY PROTECTION SERVICE (VUPS) AT 811 OR 1-800-552-7001, 48 HOURS
PRIOR TO THE START OF WORK. EXCAVATORS MUST NOTIFY ALL PUBLIC UTILITY
OPERATORS WHO MAINTAIN UNDERGROUND UTILITY LINES IN THE AREA OF
PROPOSED EXCAVATING OR BLASTING AND HAVE THOSE FACILITIES LOCATED BY THE
UTILITY COMPANIES PRIOR TO COMMENCING EXCAVATION. THE EXCAVATOR IS
RESPONSIBLE FOR COMPLIANCE WITH ALL COUNTY REQUIREMENTS, VIRGINIA CODE
AND REGULATIONS.
VICINITY MAP
SCALE: 1" = 1000'
OWNER
GRAYSTONE CORPORATION
P.O. BOX 2530
WINCHESTER, VA 22604
(540) 667-7700
DEVELOPER
GRAYSTONE CORPORATION
P.O. BOX 2530
WINCHESTER, VA 22604
(540) 667-7700
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
06/28/2019
TTC
19-09
59
2760GC
Plan Revisions
Revision
No Revision Date Comment
01 07/22/2019 Frederick Water Comments
02 08/16/2019 Frederick County Planning Comments
03 09/04/2019 Frederick County Planning Comments
04 09/17/2019 Frederick County Public Works & VDOT Comments
05 10/07/2019 Frederick County Planning Comments
06 10/21/2019 VDOT Comments
DATE
APPROVAL
ZONING ADMINISTRATOR
* SITE PLAN VALID FOR (5) FIVE YEARS FROM DATE OF APPROVAL
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
LIST OF SERVICES: CIVIL ENGINEERING I GIS I LAND SURVEYING I ENVIRONMENTAL I ANALYTICAL LABORATORY I QUALITY CONTROL TESTING & INSPECTIONS
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
N/A
2
Rev. No. Date
06 10/21/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
06/28/2019
TTC
19-09
59
2760GC
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
GE
N
E
R
A
L
N
O
T
E
S
A
N
D
L
E
G
E
N
D
FIRE MARSHAL'S NOTE
GENERAL PLAN AND CONSTRUCTION NOTES VDOT GENERAL NOTES LEGEND
FREDERICK WATER CONSTRUCTION NOTES
Fire lane markings and signage:
Any "No Parking" signs and yellow painted curb locations will be installed
by field inspection at the direction of the Fire Marshal's Office.
FREDERICK WATER PROJECT INFORMATION
WATER AND SANITARY SEWER USAGE
WATER DEMAND 2,625 GPD
SANITARY SEWER DISCHARGE 2,625 GPD
Calculation of demand/discharge
WATER DEMAND
*Residnetial: 235 gpd per connection
*Commercial: 75 gpd per 1,000 sf
*Industrial: 25 gpd @ 10 persons per acre
SEWER DISCHARGE
Sewer discharge equals water demand
PROPOSED SAN. LAT. CLEANOUT
PROPOSED CENTERLINE
EXISTING SPOT ELEVATION
STORM DRAIN STRUCTURE IDENTIFIER
SANITARY MANHOLE IDENTIFIER
PROPOSED SPOT ELEVATION
EXISTING CURB AND GUTTER
PROPOSED EDGE OF PAVEMENT
EXISTING EDGE OF PAVEMENT
PROPOSED STORM SEWER WITH INLET
EXISTING STORM SEWER WITH INLET
PROPOSED TELEPHONE LINE
EXISTING TELEPHONE LINE
TRANSITION TO REVERSE CURB
PROPOSED CURB AND GUTTER
PROPOSED ELECTRIC SERVICE
EXISTING ELECTRIC SERVICE
PROPOSED SANITARY SEWER WITH MANHOLE
EXISTING SANITARY SEWER WITH MANHOLE
PROPOSED GAS LINE
EXISTING GAS LINE
FENCELINE
FLOW LINE
PROPOSED WATERLINE W/ TEE
PROPERTY LINE
EXISTING TELEPHONE PEDESTAL
EXISTING WATERLINE W/ TEE
EXISTING UTILITY POLE/GUIDE WIRE
SIGNS
PROPOSED REDUCER
EXISTING FIRE HYDRANT/VALVE/METER
INDICATES THE NUMBER OF TYP. PARKING SPACES
PARKING INDICATOR
HANDICAP PARKING
PROPOSED BUILDING ENTRANCE
VEHICLES PER DAY COUNT
PROPOSED FIRE HYDRANT/VALVE/METER
LIGHT POLE
EXISTING TREE LINE
EXISTING EASEMENT
PROPOSED EASEMENT
EXISTING CENTERLINE
EXISTING INDEX CONTOUR
EXISTING INTERMEDIATE CONTOUR
PROPOSED CONTOUR
PROJECT INFORMATION
V1. All work on this project shall conform to the current editions of and latest revisions to the Virginia Department of
Transportation (VDOT) Road and Bridge Specifications and Standards, the Virginia Erosion and Sediment Control
Regulations, and any other applicable state, federal or local regulations. In case of a discrepancy or conflict between the
Standards or Specifications and Regulations, the most stringent shall govern.
V2. All construction shall comply with the latest U.S. Department of Labor, Occupational Safety and Health Administration
(OSHA), and Virginia Occupational Safety & Health (VOSH) Rules and Regulations.
V3. When working within VDOT right-of-way, all traffic control, whether permanent or temporary, shall be in accordance with the
current edition of VDOT’s Work Area Protection Manual. A transportation management plan needs to be submitted for
approval and land use permit issued prior to any execution of work within the VDOT right of way.
V4. The developer shall be responsible for relocating, at his expense, any and all utilities, including traffic signal poles, junction
boxes, controllers, etc., owned by VDOT or private / public utility companies. It is the sole responsibility of the developer to
locate and identify utility facilities or items that may be in conflict with the proposed construction activity. VDOT approval of
these plans does not indemnify the developer from this responsibility.
V5. Design features relating to field construction, regulations, and control or safety of traffic may be subject to change as deemed
necessary by VDOT. Any additional expense incurred as a result of any field revision shall be the responsibility of the
developer.
V6. If required by the local VDOT Land Development Office, a pre-construction conference shall be arranged and held by the
engineer and/or developer with the attendance of the contractor (s), various County agencies, utility companies and VDOT
prior to initiation of work.
V7. The contractor shall notify the local VDOT Land Development Office when work is to begin or cease for any undetermined
length of time. VDOT requires and shall receive 48 hours advance notice prior to any required or requested inspection.
V8. The contractor shall notify the Traffic Operations Center at (540) 332-9500 for any traffic control plan that impacts a VDOT
maintained Interstate or Primary roadway to provide notification of the installation and removal of the work zone.
V9. The contractor shall be responsible for maintaining a VDOT permitted temporary construction entrance(s) in accordance with
Section 3.02 of the Virginia Erosion and Sediment Control Handbook. Furthermore, access to other properties affected by
this project shall be maintained through construction.
V10. Contractor shall ensure adequate drainage is achieved and maintained on the site during and at the end of construction.
V11. All water and sewer lines within existing or proposed VDOT right-of-way shall have a minimum thirty-six (36) inches cover
and when possible shall be installed under roadway drainage facilities at conflict points.
V12. Any unusual subsurface conditions (e.g., unsuitable soils, springs, sinkholes, voids, caves, etc.) encountered during the
course of construction shall be immediately brought to the attention of the engineer and VDOT. Work shall cease in that
vicinity until an adequate design can be determined by the engineer and approved by VDOT.
V13. All fill areas, borrow material and undercut areas shall be inspected and approved by a VDOT representative prior to
placement of fill. A VDOT representative shall be present to insure the soil sample(s) obtained for CBR’s is representative
of the location. When soil samples are submitted to private laboratories for testing, the samples shall be clearly identified and
labeled as belonging to a project to be accepted by VDOT and that testing shall be performed in accordance with all
applicable VDOT standards and procedures.
V14. All roadway fill, base, subgrade material, and backfill in utility/storm sewer trenches shall be compacted in accordance with
the lift thicknesses, density and moisture requirements as specified in the current VDOT Road and Bridge Specifications.
Certified copies of test reports shall be submitted to VDOT daily, unless specified otherwise.
V15. VDOT Standard CD and UD underdrains shall be installed where indicated on these plans and/or as specified by VDOT.
V16. A post installation visual/video camera inspection shall be conducted by the Contractor on all pipes identified on the plans as
storm sewer pipe and a select number of pipe culverts. For pipe culverts, a minimum of one pipe installation for each size of
each material type will be inspected or ten percent of the total amount for each size and material type summarized. All pipe
installations on the plans not identified as storm sewer pipe shall be considered as culvert pipe for inspection purposes.
Additional testing may be required as directed by the Area Land Use Engineer or their representative.
V17. The installation of any entrances and mailboxes within any dedicated street right-of-way shall meet VDOT minimum design
standards and is the responsibility of the developer.
V18. Prior to VDOT acceptance of any streets, all required street signage and/or pavement markings shall be installed by the
developer in accordance with the Manual On Uniform Traffic Control Devices.
V19. The developer shall provide the VDOT Land Development Office with a list of all material sources prior to the start of
construction. Copies of all invoices for materials utilized within any dedicated street right-of-way must be provided to the local
VDOT Land Development Office prior to acceptance of the work. Unit and total prices may be obscured.
V20. Aggregate base and subbase materials shall be placed on subgrade by means of a mechanical spreader. Density will be
determined using the density control strip in accordance with Section 304 of the VDOT Road and Bridge Specifications and
VTM-10. A certified compaction technician shall perform these tests. Certified copies of test reports shall be submitted to
VDOT daily, unless specified otherwise. In addition to checking stone depths, a VDOT representative shall be notified and
given the opportunity to be present during the construction and testing of the density control strip.
V21. Asphalt concrete pavements shall be placed in accordance with Section 315 of the VDOT Road and Bridge Specifications.
Density shall be determined using the density control strip as specified in Section 315 and VTM-76. A certified compaction
technician shall perform these tests. Certified copies of test reports shall be submitted to VDOT daily, unless specified
otherwise. A VDOT representative shall be notified and given the opportunity to be present during the construction and
testing of the control strip.
V22. In accordance with Section 302.03, the foundations for pipe culverts thirty-six (36) inches and larger shall be explored below
the bottom of the excavation to determine the type and condition of the foundation. The contractor shall report findings of
foundation exploration to the engineer and VDOT for approval prior to placing pipe. Foundation designs shall comply with
VDOT Road and Bridge Standard PB-1. Where soft, yielding, or otherwise unsuitable foundation is encountered, the
foundation design and/or need for foundation stabilization shall be determined by the engineer and approved by VDOT.
V23. VDOT Standard Guardrail shall be installed where warranted and/or as proposed on these plans in accordance with VDOT’s
installation criteria. Final approval of the guardrail layout to be given by VDOT after grading is mostly complete.
V24. Approval of these plans shall expire five (5) years from the date of the approval letter.
V25. VDOT Standard CG-12 Curb Ramps shall be installed where indicated on these plans and/or as specified by VDOT.
V26. The foundations for all box culverts shall be investigated by means of exploratory borings advanced below proposed
foundation elevation to determine the type and condition of the foundation. The contractor shall submit copies of borehole
logs and report findings of foundation exploration to the engineer and VDOT for approval prior to constructing box.
Foundation designs shall comply with VDOT Road and Bridge Standard PB-1. Contrary to the Standard, where rock is
encountered and cast-in-place box is proposed, the thickness of bedding shall be six (6) inches. Where soft, yielding, or
otherwise unsuitable foundation is encountered, the foundation design and/or need for foundation stabilization shall be
determined by the engineer and approved by VDOT.
V27. Storm Sewer between structures 100 and 101, which crosses beneath Milburn Road, is private. Private storm sewer requires
separate permit approval and establishment of a perpetual bond prior to construction for storm sewer within the existing
prescriptive easement. Contractor to coordinate with client, obtain permit approval and set up bond prior to construction.
GENERAL
1. Greenway Engineering, Inc. (GE) has issued this plan set based on project criteria dictated by the client and municipal codes.
This plan set is not considered complete or appropriate for construction until ALL necessary agencies have given approval AND
this plan set is signed and sealed by a licensed professional. Any work, planning, scheduling, material purchases and/or
construction prior to approvals and licensed/professional sealing will be performed at the risk of the personnel authorizing work.
GE shall be held harmless from all costs, time delays and/or material changes incurred on any work that is preformed prior to
this plan set being approved and sealed.
2. The approval of these plans in no way relieves the Developer, Contractor, Subcontractor, or any of their agents of any legal
responsibility which may be required by the code of Virginia or any County enacted local ordinance, nor does it guarantee the
issuance of any required permits by the County, State, VDOT or any other governing Agency.
3. An approved set of plans as well as all applicable permits and required documents must be available at the construction site at
all times during construction. A representative of the Developer must be available at all times.
4. GE and/or the Engineer shall not not be responsible for or have control over or charge of construction means, methods,
techniques, sequences or procedures, nor for safety precautions and programs in connection with any work shown on these
plans. GE and/or the Engineer is not responsible for any Contractor's schedules or failure to carry out the work. GE and/or the
Engineer is not responsible for acts of omissions by the Contractor, Subcontractor, or their agents, employees, or any other
person performing portions of the work.
5. Methods and materials used in the construction of the improvements herein shall conform to current County Construction
Standards and Specifications and/or current VDOT Standards and Specifications. Should a conflict between design
specifications and these plans occur the most stringent requirement shall apply.
6. The Developer and/or Contractor shall be responsible for constructing the site in accordance with the approved plans and
construction documents and the scope of work shall conform with grades, depths, dimensions, ect. shown hereon.
7. All known cemetery and/or gravesite locations have been identified on these plans. Any cemetery or gravesite shown on these
plans shall be marked and protected in accordance with state law. The developer or contractor shall be responsible for
marking, installing protecting and maintaining protection of any known sites during construction and in the event that any
unknown gravesites is discovered during construction, the Owner and Engineer must be notified immediately and adequate
protection from construction shall be installed immediately.
PERMITS AND INSPECTIONS
1. The Developer or his agent shall be responsible for obtaining all required permits from the appropriate State and/or local
agencies and to comply with their requirements and all applicable National, State and Local laws and shall be responsible for
obtaining any required permits from the Virginia Department of Environmental Quality (DEQ) or the United States Army Corp of
Engineers for any plan wetland disturbance as may be shown on these plans. They shall also be responsible the identification
and delineation of any wetlands that may be present on the construction site.
2. Prior to the initiation of any land disturbing activities the Responsible Land Disturber, Developer, or the Contractor shall obtain
a Land Disturbance Permit from the Frederick County Public Works Department and shall be responsible for filing a Virginia
Stormwater Management Program (VSMP) registration statement for the construction site as required by law . They shall also
be responsible for obtaining and maintaining on site a Stormwater Pollution Prevention Plan (SWPPP). The approval of these
plans in no way relieves the developer or his agent of the responsibilities contained in the Virginia Erosion and Sediment Control
Handbook.
3. Upon completion of all construction activities and permanent site stabilization, the Developer shall submit to Frederick County
Public Works Department a DEQ Notice of Termination form, a copy of the sites construction inspection log book, an engineer
certified red-lined as-built of the approved plans with computations for all permanent stormwater management facilities, water
quality, and stormwater conveyance systems, a recorded copy of the required BMP Maintenance Agreement (if needed) , any
VSMP Permit maintenance fees (if required), and a written request to Frederick County Planning for bond release. The
Developer shall also schedule a Final on site inspection with Frederick County Public Works Department.
4. The Contractor, Owner or Developer must obtain a VDOT Land Use Permit (Entrance) from the Office of the Resident Engineer,
Virginia Department of Transportation (VDOT) and provide to Frederick County prior to any construction activities within existing
State right-of-way.
5. The Contractor, Owner or Developer shall be responsible for scheduling all required State and local inspections and for the
securing of any third party inspection/testing service to insure construction compliance with these plans and specifications and
shall keep and maintain a site inspection log book. It is Greenway Engineering's recommendation that a third party
inspection/testing service be employed to ensure that project is compliant and that materials installed meet the details and
specifications in these plans.
6. Any retaining wall 2 ft. or greater in height shall designed by a Structural Engineer require the issuance of a separate building
permit.
7. Individual sign permits will be required from the Zoning Office for all free standing and/or facade signs prior to erecting the sign
and may require a separate building permit.
UTILITIES
1. The location of existing utilities shown in these plans are taken from existing available records and may not be representative of
exact locations. It shall be the contractors responsibility to verify the exact horizontal and vertical location of all existing utilities
as needed prior to construction. The contractor shall be responsible for the digging of all test holes that may be required,
whether recommended or not by these plans, to determine the exact location and elevation of existing utilities. If any conflicts
arising from this existing utility verification or if during the course of construction, any object of an unusual nature is
encountered, the contractor shall cease work in that area and immediately notify Greenway Engineering at (540) 662-4185
and/or the proper authority. Greenway Engineering or any engineer associated with these plans shall not be responsible or
liable for any construction cost that may be associated with the installation or reinstallation any utility or other improvements if
not notified of any discrepancies between actual field conditions and the approved plan.
2. The developer will be responsible for the relocation of any existing utilities which may be required as a result of his project. Any
required relocation of existing utilities should be completed prior to construction.
3. The Developer and/or Contractor shall be responsible to supply all utility companies with copies of the approved plans and
advise them that all grading shall conform to the approved plans, and further that the utility companies shall be responsible for
honoring these plans and the finished grades in the installation of their utility lines.
4. All proposed utilities to be located underground.
5. The Developer and/or Contractor shall notify operators who maintain underground utility lines in the area of proposed
excavating or blasting at least two (2) working days, but not more than ten (10) working days, prior to commencement of
excavation or demolition.
6. The developer shall be responsible for notifying Frederick Water and all other appropriate utility companies prior to construction
of water and/or sanitary sewer lines. Information should also be obtained from the appropriate authority concerning permits, cut
sheets, and connections to existing lines.
7. All sanitary sewers, water mains and appurtenances shall be constructed in accordance with the current standards and
specifications of Frederick Water.
8. When grading is proposed within easements of utilities, letters of permission from all involved companies must be provided to
the Frederick County Public Works Department prior to issuance of grading and/or site development permits.
9. The developer shall be responsible for any damage to the existing streets and/or utilities which may occur as a result of
construction within or contiguous to an existing right-of-way or utility.
10. All stormwater piping and structures shown on these plans are only accurate to the inlet or manhole locations as shown hereon.
Detail design of stormwater structures were not provided to Greenway Engineering. Actual pipe alignments will be based upon
developed structural shop drawings as provided by the manufacturer. Contractor shall make adjustments to pipe alignments
base on provided shop drawings. Greenway Engineering will not be held responsible or liable for any discrepancies or changes
caused by the structural design. Contractor may submit shop drawings to Greenway Engineering for review and approval at
contractor's expense. Shop drawings will be reviewed for compliance with design plans. The Owner or Developer will be
responsible for any redesign as a result of structural shop drawing design.
11. All parking lot/street light and dry utility design shall be performed and provided separately by others. All dry utility, structural
base design, electrical design, photometrics and or other lighting information shown hereon is as specified by others and is
included for informational purposes only, as directed by the Owner, Developer and/or public agency requirements. Greenway
Engineering has not performed any lighting and/or dry utility design and does not warrant and is not responsible for the degree
and/or adequacy of illumination on this project or the adequacy of the dry utility to service the site. Any changes to the lighting
design, once the plan is approved, shall be approved by the County prior to installation.
SITEWORK
1. Refer to the Geotechnical Engineer Report for methods, materials and details for construction of all earthwork activities.
2. All vegetation, root material, topsoil, and any other unsuitable material shall be removed from the construction limits of the site
before removal or placing of fill material. Earthwork clearing shall extend a minimum of 10' beyond all building and pavement
limits with an additional 1 foot of clearance for each foot of fill required.
3. Controlled (Structural) fills shall be compacted to 95% of maximum dry density as determined by method "A" per standard
proctor AASHTO-T99, ASTM-D698, or VTM-1 as applicable (Non-structural fills 85% to 90%). Structural fills shall extend a
minimum of 5' beyond the limits of all foundation elements at bearing elevation. Density shall be certified by a registered
professional engineer and results submitted to Frederick County prior to pavement construction. If a geotechnical report has
been prepared, it should supersede the requirements in this note. No visual pumping, no rocks larger than 6-inches. Materials
classified as OL, OH, MH or PT are not suitable for use as structural fill. All fill should be placed on stable subgrades. Fill should
not be placed on surfaces that are muddy or frozen, or have not been approved by testing and/or proof-rolling. All fill material
compacted by heavy compaction equipment should be placed in maximum 10-inch loose lifts. All fill material compacted by
hand-operated tampers or light compaction equipment should be placed in maximum 4-inch loose lifts. Fill placed on sloping
ground should be properly benched into residual soils such that a smooth interface will not be present. Fill material placed
below and extending 10 feet beyond the foundations for the structure should be compacted to at least 98% of maximum dry
density as determined by the Standard Proctor Test Method (ASTM-D698).
4. All fills greater than 2 feet shall require compaction testing.
5. All fills with slopes steeper than 3:1 or more than 10 feet in height shall require a Slope Stability Analysis.
6. All fill embankments being constructed against slopes of existing embankments or hillsides; or across existing embankments,
hillsides, and depressions at a skew angle of 30 degrees or more or slopes are steeper than 4:1 shall be benched in a series of
horizontal cuts beginning at the intersection with original ground and continuing at each vertical intersection with the previous
cut. Material removed during benching shall be placed and compacted as embankment material. For existing slopes steeper
than 4:1 but less than 1 12:1, the bench shall be a minimum of 6 feet wide. For existing slopes steeper than 1 12:1 but less than
12:1, the bench shall be a minimum of 4 feet wide.
7. All pavement sections shown on these approved plans are based on a minimum CBR value of 6 and are for preliminary design
only. Final pavement design shall be based upon actual CBR values. The Contractor or Developer shall be responsible for field
tests per VDOT standards to obtain actual CBR values for final design. Final pavement designs will be approved by VDOT
and/or the Owner/Developer, which ever applicable, prior to installation. GE shall be held harmless from all costs, time delays
and/or material changes incurred on any work that is preformed prior to final pavement design approval.
8. Concrete for pads and/or sidewalks shall be a minimum Class A3 or 3000 psi (with air) and shall be placed in accordance to
ACI practices or as otherwise specified per structural design. All concrete areas requiring a separate permit shall be designed
by a registered professional structural engineer.
9. The contractor shall provide adequate means of cleaning mud from trucks and/or other equipment prior to entering public
streets, and it is the contractors responsibility to clean streets, allay dust, and to take whatever measures are necessary to
insure that public streets are maintained in a clean, mud and dust free condition at all times.
10. Warning signs, markers, barricades or flagmen should be in accordance with the State and Federal Manual on Uniform Traffic
Control Devices (MUTCD).
11. The exact location of all guard rails and paved ditches will be determined by VDOT personnel. "A joint inspection will be held
with the Developer, County Representatives, and Representatives of the Virginia Department of Transportation (VDOT) to
determine if and where guard rail and/or paved ditches will be needed. The developer will be responsible for providing guardrail
and paved ditches as determined by this joint inspection." Refer to Virginia Department of Transportation (VDOT) Guard Rail
and Paved Ditch Specifications.
12. Any changes to the approved Landscape Plan shall be approved approved by the County prior to installation.
13. All springs shall be capped and piped to the nearest storm sewer manholes or curb inlet. The pipe shall be minimum 6"
diameter and conform to VDOT standard SB-1.
14. Construction debris shall be containerized in accordance with the Virginia Litter Control Act; no less than one litter receptacle
shall be provided at the construction site.
15. All excavations shall be benched according to OSHA regulations to permit safe entry.
PERMANENT STORMWATER MANAGEMENT EMBANKMENTS
1. Satisfactory fill materials for use in constructing permanent stormwater management facility embankments shall include
materials classified in ASTM D-2487 as GC, GM, SC, SM, CL, or MI groups. Soils must contain a minimum of 20% plus No. 200
sieve and be "Well Graded" material, with no stones greater than 6 inches, mixed with the clay. A minimum of three samples
shall be classified.
2. All fill areas shall be "Keyed In" and compacted in horizontal layers not to exceed a maximum loose lift of 8 inches thick. All fill
shall be compacted with a sheepsfoot, rubber-tired or vibratory roller to a density of 100% of maximum dry density with a
moisture content within +/- 2% of optimum per Standard Procter Test (ASTM D698) or the Modified Proctor Test (ASTM D1557)
as director by the geotechnical engineer. Compaction test shall be performed at one test per 5,000 square feet on each layer.
3. Principal spillway must be installed concurrently with fill placement and not excavated into the embankment. All fills beside
pipes or structures shall be placed in horizontal layers not to exceed 4 inches in depth and shall be compacted by hand
tampers. Fill material shall completely fill all spaces under and beside pipes. Equipment should not be driven within 4 feet of any
structure part during backfilling operation and shall never be driven over until compacted fill has been placed to a depth
specified by the structural live load capacity of the structure or pipe.
4. Embankments shall be constructed with a relatively impervious core and cutoff trench. Core material shall be classified as GC,
SC, or CL. The cutoff trench shall be excavated in impervious material a minimum of depth and width of 4 feet with side slopes
no steeper than 1:1 and located at or upstream of the embankment centerline. The impervious core shall extend up to the
10-year water surface elevation (see engineering design). The surface of the embankment shall be covered with a minimum 6
inches of clean topsoil and stabilized with grass.
5. Stormwater management facility earthen embankments shall not be greater than 25' in height measured from the downstream
toe of slope to the top of the embankment with embankment slopes no steeper than 2:1and a combined minimum upstream and
downstream slope of 5:1. The minimum top width of the embankment shall be 8' for embankments 14' or less in height and shall
be level.
6. Any groundwater seepage encountered during cutoff trench construction shall be drained by means of a foundation drain to the
outside/ downstream toe of the embankment slope. Foundation drains shall be downstream and outside of the limits of the
cutoff trench. The constructed foundation drain section shall be an excavated 2' x 2' trench backfilled with hand compacted #57
stone wrapped in geotextile fabric.
7. A geotechnical or construction inspector should be on site during embankment construction.
8. All embankment construction, compaction testing, and construction inspections shall be the responsibility of the site contractor.
CONSTRUCTION STAKE-OUT/ ASBUILTS
1. All stake-out to be performed by GE. If the contractor does not utilize GE for stake-out then the contractor assumes all liability
for accuracy of construction.
2. All cutsheet and grades are to be reviewed by Engineer of Record prior to issuance for construction.
3. Asbuilts of the SWM system is required to verify conformance with the approved plans. Please contact GE when installation is
complete.
4. All stormwater collection, stormwater management and water quality features must be inspected by Engineer of Record during
construction. As-built certification, required to terminate VSMP permit and bond release with the County upon the completion of
the project, must be completed by GE.
TOPOGRAPHY
1. Topography shown on this plan has been conducted per the VA Administrative code 18VAC10-20-382 and the minimum
standards and procedures set forth in chapter 4 (§ 54.1-400 et seq.) of Title 54.1 of the Code of Virginia. This plan shows the
design assumptions utilizing these accuracy standards. Inverts and other elevations shown hereon must be field verified by the
contractor prior to construction. If a discrepancy is found, the contractor shall cease work in that area and immediately notify
Greenway Engineering. Greenway Engineering shall be held harmless for any discrepancies or conflicts if not notified
immediately.
2. Contractor shall confirm all existing tie-in points of this project prior to the start of construction. GE shall be notified of any
discrepancies between actual field conditions and the approved plan prior to the start of construction.
1. Frederick Water’s Water and Sewer Standards and Specifications are available at www.frederickwater.com
2. The contractor shall adhere to Frederick Water standards and specifications in effect at the time of construction.
3. The contractor shall coordinate with and arrange for inspection by Frederick Water.
4. The contractor shall connect a new sewer line to an existing manhole by core drilling the manhole.
5. A new water (or forced sewer) main shall be connected to an existing main by a wet tap. Frederick Water shall furnish all needed material and make the tap. a. An Application for Wet Tap shall be submitted and the initial fee paid before the tap is made.
6. Exact locations of water and sewer services on new lines are to be coordinated with Frederick Water’s inspector.
7. Frederick Water’s maintenance division shall furnish and install all water meters through 2 inch in size. It is the contractor’s responsibility to have the meter box assembly installed correctly.
Before a permanent meter is installed:a. The meter box, with its frame and cover, must be properly aligned with the yoke bar.
b. The frame and cover shall be set to final grade.
c. The distance between the top of the cover and the yoke bar shall be between 20 and 23 inches.
d. All components of the meter box assembly shall be in proper working order.
8. For services that connect to existing lines:
a. Frederick Water shall furnish and install:
i. all ⅝”x¾”, ¾”, 1”, 1½” and 2” water servicesii. all sewer services.
b. The owner/developer shall:
i. coordinate (or have the contractor coordinate) the location of the service lateral with Frederick Water’s engineering assistant.
ii. submit an Application for Service and pay the required fees.
9. All water service lines must have a backflow prevention assembly (double check valve or RPZ, as required). The
assembly must meet ASSE standard number 1015 or 1013.
10. All fire lines must have a backflow prevention assembly (detector double check valve or RPZ, as required). The assembly shall meet ASSE standard number 1048 or 1047. Any privately owned fire line, interior or exterior, shall
also have a fire service HP Protectus III meter. This assembly shall be installed immediately before the backflow prevention unit. Radio read remotes are required.
11. Frederick Water shall review the mechanical plan(s) for design and material approval of a building’s: a. domestic water meter and its backflow prevention device, and/or its
b. Fire service line’s water meter and backflow prevention device.
12. DEQ must also approve sewer pump stations. Frederick Water requires a copy of DEQ’s Certificate to
Operate and a copy of the station’s DEQ approved O&M manual. These documents must be received
before substantial completion is issued and water meters released.
January 2019
USECLASS * TRIP RATE
TRIP GENERATION DATA
UNITS VPD
* TAKEN FROM ITE TRIP GENERATION 9TH EDITION
152
High-Cube Warehouse/
Distribution Center 238,760sf 1.68/ 1000 sf 402
PHASE
1
FREDERICK WATER SANITARY SEWER TIE IN NOTE
No meters shall be released, or connections allowed to the downstream sewer collection system as shown on the
“Sanitary Sewer Plan For Graystone & Stephenson Village dated Nov 24, 2017 revised 7/02/18”, until said sanitary sewer is
made operational and has been fully accepted by Frederick Water, which includes providing Frederick Water with a copy
of the recorded off-site sanitary sewer easements. The property owner assumes all risk and accepts all delays associated
with construction of the subject parcel prior to completion of the downstream sewer collection system.
This site is located in the M1 zoning district and the owner has requested a reduction in a portion of the zoning district buffer
as the site meets the criteria outlined in §165-203.02(D)(6). The placement of Onyx Drive requires a reduction of the active
distance buffer to zero (0) for a length of +/- 680-feet, depicted on Sheets 3, & 18 - 20. All portions of the 75-FT inactive
buffer and non-modified portions 25-FT active buffer remain as required. All other buffers and setbacks described in the
project section located on this plan sheet.
BUFFERS
Parcel Identification No: 44-A-25 & 44-A-26 & 44-A-31A
Street Address: #TBD - Onyx Drive
Project Site Area: 80.44 Acres
Disturbed Area: 37.87 Acres
Current Zoning: M1
Current Use: Vacant/Agricultural
Proposed Use: Warehouse Building
Previously Approved Plans: REZ #09-09; REZ #03-12; MDP #01-15
Maximum Building Height: 60'
Proposed Building Height: 50' (bldg 1), 50' (bldg 2)
Building 1 Building 2
Required Yard Setbacks: Provided Yard Setbacks
Front: 75' Front: 163.0'Front: 663.0'
Side: 25'/*100' Side: 172.6'Side: 173.8'
Rear: 25'/*100' Rear: 1069.5'Rear: 603.6'
*Buildings are not allowed in any proffered/required natural state buffer(100'), active(25') or inactive buffers(75')
Required Parking Setbacks: Provided Parking Setbacks
Front: 25' Front: 92.4'Front: 486.3'
Side: 5'/**75' Side: 144.8'Side: 158.3
Rear: 5'/**75' Rear: 1184.8'Rear: 541.6'
**Parking is not allowed in any proffered inactive buffers (75') required for buffer/screening
Required Sign Setbacks: Provided Sign Setbacks
Front: 10' Front: N/A Front: N/A
Side: 10' Side: N/A Side: N/A
Rear: 10' Rear: N/A Rear: N/A
Building 1 Building 2
Parking Spaces Required: 1 Per 250 SF Office Floor Area
1.5 Per Warehouse Employee
1,000 SF / 250 = 4 Spaces 2,000 SF / 250 = 8 Spaces
12 Emp. x 1.5 = 18 Spaces/Shift (Peak) 70 Emp. x 1.5 = 105 Spaces/Shift (Peak)
Parking Spaces Required: 22 Spaces 113 Spaces
Total Spaces Provided: 23 Spaces 113 Spaces
ADA Spaces Required: (Per Table 1106.1(1) of the 2015 Virginia Construction Code)
1 Spaces 5 Spaces
ADA Spaces Provided: 4 Spaces 8 Spaces
Loading Spaces Required: 1 Per 40,000 SF of Floor Area
63000 SF / 40,000 = 2 Spaces 175,760 SF / 40,000 = 5 Spaces
Loading Spaces Provided: 20 Spaces/Dock 84 Spaces/Dock
Far Calculation: Total Lot Area = 80.44 Acres (3,503,966 SF)
Total Floor Area = 5.48 Acres (238,760 SF)
Building Area/Lot Area = 0.07 < 1.0
Open Space Calculations:
Required - 25% = 20.11 Acres
Provided - 85% = 68.24 Acres
Outdoor Lighting: All lighting shall conform to section 165-201.07 of the Frederick County zoning ordinance
Signs: All signs shall conform to 165-201.06
Security: No guard shack or security fencing is proposed with this project. If a guard shack or fencing
is proposed at a later date then a plan will be submitted for county staff review
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
X X
X
X
X
X
X
X
X
X X X
X X
X X X X X X X X X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
S
S
S
S
S
S
X
X
X
X
X
X
X
GRID M
E
R
I
D
I
A
N
VA NOR
T
H
Z
O
N
E
N
A
D
8
3
SURVEY AND TOPOGRAPHIC INFORMATION
2. Aerial, horizontal and vertical control surveys were
Dated:
3. Aerial topographic mapping performed by:
1. Boundary survey was performed by:
performed by:
Date
Dated:GREENWAY ENGINEERING 10/09/2003
VIRGINIA MAPPING DECEMBER 2004
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
BO
U
N
D
A
R
Y
A
N
D
E
X
I
S
T
I
N
G
T
O
P
O
Rev. No. Date
05 10/07/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
1" = 100'
3
06/28/2019
TTC
19-09
59
2760GC
NOTES:
1. OWNER ACKNOWLEDGES THE POTENTIAL IMPACT OF THE ROUTE 37
DEVELOPMENT ON THE PROPOSED PHASE I BUILDING FOOTPRINTS.
6
2
5
.
6
W
E
W
E
6
2
5
.
6
GRID M
E
R
I
D
I
A
N
VA NOR
T
H
Z
O
N
E
N
A
D
8
3
FUTURE BUILDING #5
PROP. WAREHOUSE
FACILITY
175,760 SF
APPROX. FFE = 629.20
FUTURE BUILDING #4
PROP. WAREHOUSE
FACILITY
178,500 SF
APPROX. FFE = 627.60
FUTURE BUILDING #3
PROP. WAREHOUSE
FACILITY
209,560 SF
APPROX. FFE = 634.70
BUILDING #2
PROP. WAREHOUSE FACILITY
175,760 SF
APPROX. FFE = 630.70
BUILDING #1
PROP. WAREHOUSE
FACILITY
63,000 SF
APPROX. FFE = 631.00
SWM RETENTION
POND
E
X
.
T
R
A
I
L
E
X
.
T
R
A
I
L
ONYX
D
R
I
V
E
(PRIVA
T
E
A
C
C
E
S
S
)
O
N
Y
X
D
R
I
V
E
(P
R
I
V
A
T
E
A
C
C
E
S
S
)
ONYX DRIVE
(PRIVATE ACCESS)
FUTURE
PHASE 2
FUTURE
PHASE 3
P
H
A
S
E
2
P
H
A
S
E
1
P
H
A
S
E
3
P
H
A
S
E
1
PHA
S
E
2
PHA
S
E
3
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
OV
E
R
A
L
L
S
I
T
E
P
H
A
S
I
N
G
P
L
A
N
Rev. No. Date
05 10/07/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
1" = 100'
4
06/28/2019
TTC
19-09
59
2760GC
NOTES:
1. OWNER ACKNOWLEDGES THE POTENTIAL IMPACT OF THE ROUTE 37
DEVELOPMENT ON THE PROPOSED PHASE I BUILDING FOOTPRINTS.
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
X X
X
X
X
X
X
X X X X X X X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
6
2
5
.
6
W
E
W
E
6
2
5
.
6
S
S
S
S
S
S
S
S
S
GRID M
E
R
I
D
I
A
N
VA NO
R
T
H
Z
O
N
E
N
A
D
8
3
PROP.
BOULDER
STOCKPILE
LCG
ROUGH GRADING AND BERM MAY BE
COMPLETED DURING PHASE I/II E&S.
FINAL GRADING AND PLANTS SHALL
NOT BE INSTALLED UNTIL ALL
UPSTREAM DRAINAGE AREAS ARE
STABILIZED.
AREA 1
AREA 2
AREA 3
AREA 4
CE
CE
LCG
LCG
LCG
LCG
LCG
LCG
COORDINATE RELOCATION OF
ONSITE UTILITIES AS PHASE I
MEASURE (SEE SHEET 21 FOR
PROPOSED RELOCATION)
CE
SSF
SCC
DD
CD
TSB/M
SSF
SCC
TSB/M
DD
SILT FENCE MAY BE REMOVED AFTER
STABILIZATION OF STORM CHANNEL
AREA TO SB #1
DA=16.45 A.C.
SB#1
DD
DD
DD
SCC
SCC
SCC
B/M
DD
DD
DD
DD
SCC
B/M
SSF
SSF
SILT FENCE MAY BE REMOVED AFTER
STABILIZATION OF STORM CHANNEL
PS
PS
OP
CIPCV2
CV1
B
C
1
B
C
2
SSF
SILT FENCE MAY BE
REMOVED AFTER
STABILIZATION OF
STORM CHANNEL
OP
CV6
CV5
EX.15" RCP TO
BE REMOVED
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
OV
E
R
A
L
L
E
&
S
P
L
A
N
Rev. No. Date
04 09/17/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
1"=100'
5
06/28/2019
TTC
19-09
59
2760GC
SHE
E
T
S
7 & 11
SHE
E
T
S
8 &12
SHEETS 9 & 13
AREA OF CONCERN - CONTRACTOR TO INVESTIGATE
CONDITIONS FOR STABILITY AND CONSULT WITH A
GEOTECHNICAL ENGINEER FOR STRUCTURAL FILL
REQUIREMENTS SHOULD IT BE DETERMINED AREA IS UNSTABLE
TEMPORARY GRAVEL
CONSTRUCTION ENTRANCE
SUPER SILT FENCE
TEMPORARY DIVERSION DIKE
CULVERT INLET PROTECTION
ROCK CHECK DAMS
SILT FENCE
LIMITS OF CLEARING & GRADING
DRAINAGE DIVIDES
OUTLET PROTECTION
NO. KEY SYMBOL DESCRIPTION
3.09
3.08
3.20
3.05
3.18
3.02
LCG
OP
DD
CIP
SSF
SF
CE
CD
SAFETY FENCE3.01 SAF
3.32 PS PERMANENT SEEDING
IP STORM DRAIN
INLET PROTECTION3.07
3.36 B/M SOIL STABILIZATION
BLANKETS & MATTING
EROSION/SEDIMENT CONTROL LEGEND
STORMWATER
CONVEYANCE CHANNEL3.17 SCC
TEMPORARY SEDIMENT BASIN3.14 SB
3.31 TS TEMPORARY SEEDING
SHEET 6
NOTE:
SEE: SHEET 6
FOR OFFSITE
BORROW AND
STOCKPILE
AREAS.
FOR PHASE I EROSION AND SEDIMENT CONTROL ONLY !!
NOTES:
1. SLOPES 3:1 AND GREATER SHALL BE PROTECTED WITH SOIL
STABILIZATION BLANKETS (EC-2).
2. REFER TO SHEETS 43-44 FOR DITCH SECTIONS AND COMPUTATIONS
640660
6
1
0
64
0
650
65
0
64
0
650
65
0
640
64
0
65
0
66
0
660
660
660
660
650
650
640
610
620
630 640
650
650
630
630
650
620
640
650
630
64
0
64
0
620
63
0
6
5
0
65
0
T.M. 44-A-31A
ZONE: R4
OWNER: STEPHENSON
ASSOCIATES, L.C.
USE: UNIMPROVED
BORROW STAGING AREA
BORROW AREA 1
WETLANDS
DO NOT
DISTURB!
CONSTRUCTION
ENTRANCE ONTO
MILBURN ROAD
DRIVE FOR
ACCESS TO
BORROW
AREAS
EX. FARM
ROAD
30' TEMP ACCESS
ESMT
30' TEMP ACCESS
ESMT
CONSTRUCTION
ENTRANCE ONTO PROP.
GRAYSTONE DRIVE
WETLANDS
DO NOT
DISTURB!
WETLANDS
DO NOT
DISTURB!
WETLANDS
DO NOT
DISTURB!
WETLANDS
DO NOT
DISTURB!
SEE INSERT
THIS SHEET
DEMOLISH
FENCE
DEMOLISH
FENCE
DRAINAGE
DIVIDES (TYP)
CULVERT #2 CULVERT #3
CULVERT #1
10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50
635
640
645
650
655
625
630
644.557
3.77%
-1.38%
PV
C
S
T
A
.
1
0
+
5
9
.
2
8
PV
C
E
L
E
V
.
6
4
6
.
7
9
PV
I
S
T
A
.
1
1
+
0
9
.
2
8
PV
I
E
L
E
V
.
6
4
8
.
6
8
PV
T
S
T
A
.
1
1
+
5
9
.
2
8
PV
T
E
L
E
V
.
6
4
7
.
9
9
100.00VC
179.03SD
3.77%-1.38%
19.42K-Val
CREST STA.11+32.53
CREST ELEV.648.18
-2.25%
PV
C
S
T
A
.
1
4
+
1
6
.
3
9
PV
C
E
L
E
V
.
6
4
4
.
4
5
PV
I
S
T
A
.
1
4
+
6
6
.
3
9
PV
I
E
L
E
V
.
6
4
3
.
7
6
PV
T
S
T
A
.
1
5
+
1
6
.
3
9
PV
T
E
L
E
V
.
6
4
2
.
6
4
100.00VC
813.33SD
-1.38%-2.25%
114.86K-Val
3.54%
PV
C
S
T
A
.
1
5
+
7
1
.
1
7
PV
C
E
L
E
V
.
6
4
1
.
4
0
PV
I
S
T
A
.
1
6
+
2
1
.
1
7
PV
I
E
L
E
V
.
6
4
0
.
2
8
PV
T
S
T
A
.
1
6
+
7
1
.
1
7
PV
T
E
L
E
V
.
6
4
2
.
0
5
100.00VC
121.16SD
-2.25%3.54%
17.27K-Val
SAG STA.16+10.00
SAG ELEV.640.97
PV
C
S
T
A
.
1
8
+
1
7
.
3
7
PV
C
E
L
E
V
.
6
4
7
.
2
3
PV
I
S
T
A
.
1
8
+
6
7
.
3
7
PV
I
E
L
E
V
.
6
4
9
.
0
0
PV
T
S
T
A
.
1
9
+
1
7
.
3
7
PV
T
E
L
E
V
.
6
4
9
.
2
5
100.00VC
268.15SD
3.54%0.50%
32.83K-Val
CL
-2.0%
ESMT ESMT
12" VDOT 21A STONE
3:1 S
L
O
P
E
30' ACCESS ESMT
2:
1
S
L
O
P
E
NOTES:
1. THE BORROW AREA ACCESS ROAD CROSSES A CORPS OF ENGINEERS DOCUMENTED WETLAND. DISTURBANCE OF THIS WETLAND SHALL BE KEPT TO A MINIMUM DURING THE
CONSTRUCTION PHASE AND MUST STAY WITHIN THE ALLOWABLE AREA OF DISTURBANCE. THE CROSSING SHALL ONLY BE FOR ONE VEHICLE CROSSING AT A TIME (MAX 12'
WIDTH). THE CROSSING SHALL BE STABILIZED WITH STONE/RIPRAP AND CULVERTS AS SHOWN ON THE PLANS. THE WETLAND CROSSINGS ARE CURRENTLY A PART OF AN
EXISTING WETLAND MITIGATION PERMIT WITH THE USCOE AND THE VADEQ. THE CONTRACTOR MUST FOLLOW THE WETLAND MITIGATION PERMIT FOR THE CONSTRUCTION OF
THIS BORROW ACCESS ROAD.
2. CONTRACTOR IS REPONSIBLE FOR PROVIDING SERVICES FOR RELOCATION OF BORROW MATERIAL TO THE ROAD PROJECT WHILE STILL MAINTAINING THE BORROW AREA AS A
USABLE AND DEVELOPABLE SITE. FINAL GRADES IN THE AREA SHALL NOT BE GREATER THAN 15% SLOPES UNLESS APPROVED BY THE OWNER AND PROJECT MANAGER PRIOR
TO THE START OF EARTH REMOVAL FOR BORROW. IF AT THE END OF CONSTRUCTION THERE ARE AREAS FOUND THAT ARE GREATER THAN 15%, THE CONTRACTOR WILL BE
RESPONSIBLE, AT THEIR OWN COST, TO RESTORE THE BORROW AREA TO GRADES OF LESS THAN 15%. ALL AREAS WITHIN THE BORROW AREA, STAGING AREA, ACCESS ROAD
OR OTHER DISTURBED AREAS MUST BE STABILIZED PER VESCH REQUIREMENTS BEFORE BONDS WILL BE RELEASED.
WETLAND PROTECTION NOTE:
1. ORANGE SAFETY FENCE TO BE INSTALLED AROUND THE PERIMETER OF THE
WETLANDS TO MAINTAIN A 15' BUFFER. AS SHOWN.
BORROW ROAD - PROPOSED ALIGNMENT PROFILE
SCALE 1"=50' (H), 1"=5' (V)
BORROW ROAD NOTE:
1. REMAINING BORROW ROAD NOT SHOWN IN PROFILE TO BE
INSTALLED AT EXISTING GRADE FROM STA 19+50 TO 27+85.82.
2. CULVERT PROFILES SHOWN ON STM PROFILE SHEET THIS PLAN SET.
640 640
638
6
4
2
642
644
6'
BORROW ROAD SECTION - N.T.S.
FULL LENGTH
6'
COMPACTED SUBGRADE
9'9'
WETLAND DETAIL AREA
SCALE 1"=30'
#2
#3
MI
L
B
U
R
N
R
O
A
D
(R
T
6
6
2
)
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
OF
F
S
I
T
E
B
O
R
R
O
W
S
I
T
E
E
&
S
P
L
A
N
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
AS SHOWN
6
06/28/2019
TTC
19-09
57
2760GC
Rev. No. Date
WETLANDS
DO NOT
DISTURB!
CULVERT #1
(24" CMP)
CULVERT #2
(15" CMP)
CULVERT #3
(30" CMP)
ORANGE
SAFETY
FENCE
(SEE NOTE)
EX GAS
TRANS.
MAIN
12' GRAVEL
BORROW ROAD
30' ACCESS
EASEMEN
WETLANDS
DO NOT
DISTURB!
ORANGE
SAFETY FENCE
(SEE NOTE)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X
X
X
X
X
X
X
X
X
X
X
S
S
S
S
S
S
S
S
S
S
S
S
S
S
X
X
X
X
X
X
X
X
X
LCG
LCG
LCG
LCG
LCG
DD
OP
DD
DD
DD
LCG
B/M
CIP
PS
PS
PS
SF
SF
SCC
SCC
SCC
SCC
SCC
SSF
SSF
SSF
SSF
SCC
SCC
DD
DD
GR
I
D
M
E
R
I
D
I
A
N
VA
N
O
R
T
H
Z
O
N
E
N
A
D
8
3
GR
I
D
M
E
R
I
D
I
A
N
VA
N
O
R
T
H
Z
O
N
E
N
A
D
8
3
ROU
G
H
G
R
A
D
I
N
G
A
N
D
B
E
R
M
M
A
Y
B
E
COM
P
L
E
T
E
D
D
U
R
I
N
G
P
H
A
S
E
I
/
I
I
E
&
S
.
F
I
N
A
L
GRA
D
I
N
G
A
N
D
P
L
A
N
T
S
S
H
A
L
L
N
O
T
B
E
INS
T
A
L
L
E
D
U
N
T
I
L
A
L
L
U
P
S
T
R
E
A
M
D
R
A
I
N
A
G
E
ARE
A
S
A
R
E
S
T
A
B
I
L
I
Z
E
D
.
AREA 1 (SEE NARRATIVE)
AREA 2 (SEE NARRATIVE)
AREA TO SB #1
DA=16.45 A.C.
SILT FENCE MAY BE REMOVED
AFTER STABILIZATION OF STORM
CHANNEL
ES-S
E
C
"
1
"
EXISTING CULVERTS
PROPOSED
CULVERT
PROPOSED
CULVERTS
EX. 15" RCP TO
BE REMOVED
X-SEC "1"
X-SEC "2"
X-S
E
C
"
3
"
X-S
E
C
"
3
"
X-SEC "1"
X-SEC "2"
X-SEC "4"
X-SEC "4"
X-SEC "6"
X-SEC "6"
X-SEC "5"
X-SEC "5"
DD
TS
TS
B/M
B/M
B/M
CV2
CV1
BC1
BC2
OPCV6
CV5
CIP
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
E&
S
P
H
A
S
E
I
Rev. No. Date
06 10/21/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
1" = 40'
7
06/28/2019
TTC
19-09
59
2760GC
MATCH LINE SHEET 8
MAT
C
H
L
I
N
E
S
H
E
E
T
9
FOR PHASE I EROSION AND SEDIMENT CONTROL ONLY !!
AREA OF CONCERN - CONTRACTOR TO INVESTIGATE
CONDITIONS FOR STABILITY AND CONSULT WITH A
GEOTECHNICAL ENGINEER FOR STRUCTURAL FILL
REQUIREMENTS SHOULD IT BE DETERMINED AREA IS UNSTABLE
TEMPORARY GRAVEL
CONSTRUCTION ENTRANCE
SUPER SILT FENCE
TEMPORARY DIVERSION DIKE
CULVERT INLET PROTECTION
ROCK CHECK DAMS
SILT FENCE
LIMITS OF CLEARING & GRADING
DRAINAGE DIVIDES
OUTLET PROTECTION
NO. KEY SYMBOL DESCRIPTION
3.09
3.08
3.20
3.05
3.18
3.02
LCG
OP
DD
CIP
SSF
SF
CE
CD
SAFETY FENCE3.01 SAF
3.32 PS PERMANENT SEEDING
IP STORM DRAIN
INLET PROTECTION3.07
3.36 B/M SOIL STABILIZATION
BLANKETS & MATTING
EROSION/SEDIMENT CONTROL LEGEND
STORMWATER
CONVEYANCE CHANNEL3.17 SCC
TEMPORARY SEDIMENT BASIN3.14 SB
3.31 TS TEMPORARY SEEDING
NOTES:
1. SLOPES 3:1 AND GREATER SHALL BE PROTECTED WITH SOIL
STABILIZATION BLANKETS (EC-2).
2. REFER TO SHEETS 43-44 FOR DITCH SECTIONS AND COMPUTATIONS
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
63
0
630
630
620
6
2
0
6
2
0
LCG
LCG
LCG
DD
DD
DD
DD
B/M
B/M
PS
PS
B/MPS
LCG
SCC
SCC
SCC
SCC
SSF
DD
DD
DD
SSF
GR
I
D
M
E
R
I
D
I
A
N
VA
N
O
R
T
H
Z
O
N
E
N
A
D
8
3
DESIGN HIGH WATER
(100YR STORM) = 614.6
WET STORAGE
610
DRY STORAGE
611.5
6
0
6
6
0
8
6
1
0
61
2
614
616
608
610
612
614
616
611
.
5
61
4
.
6
614 616
616
614 61
2
6
1
0
6
0
8
612
614
616
6
1
8
6
1
6
607
SEDIMENT CLEAN OUT LEVEL
608.7
6
1
4
ROU
G
H
G
R
A
D
I
N
G
A
N
D
B
E
R
M
M
A
Y
B
E
COM
P
L
E
T
E
D
D
U
R
I
N
G
P
H
A
S
E
I
/
I
I
E
&
S
.
F
I
N
A
L
GRA
D
I
N
G
A
N
D
P
L
A
N
T
S
S
H
A
L
L
N
O
T
B
E
INS
T
A
L
L
E
D
U
N
T
I
L
A
L
L
U
P
S
T
R
E
A
M
D
R
A
I
N
A
G
E
ARE
A
S
A
R
E
S
T
A
B
I
L
I
Z
E
D
.
AREA 2 (SEE NARRATIVE)
AREA 3 (SEE NARRATIVE)
AREA 4 (SEE
NARRATIVE)
AREA TO SB #1
DA=16.45 A.C.
SILT FENCE MAY BE
REMOVED AFTER
STABILIZATION OF
STORM CHANNEL
EMERGENCY
SPILLWAY
ELEVATION 613.5
WIDTH 16'
VDOT CLASS 1
RIPRAP
1' DEEP
W/ FILTER FABRIC
X-SEC "10"X-SEC "10"
X-SEC "11"X-SEC "11"
X-SEC "12"
X-SEC "12"
X-SEC "15"
X-SEC "15"
X
-
S
E
C
"
1
6
"
X
-
S
E
C
"
1
6
"
SC 150 LINING OR
APPROVED
EQUIVALENT
SSF
TS
TS
SSF
HAU
L
R
O
A
D
C
R
O
S
S
I
N
G
OPE
R
A
T
I
O
N
(
F
I
G
U
R
E
T
T
C
-
5
1
.
0
)
PER
C
U
R
R
E
N
T
E
D
I
T
I
O
N
O
F
T
H
E
VIRG
I
N
I
A
W
O
R
K
A
R
E
A
PRO
T
E
C
T
I
O
N
M
A
N
U
A
L
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
E&
S
P
H
A
S
E
I
Rev. No. Date
04 09/17/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
1" = 40'
8
06/28/2019
TTC
19-09
59
2760GC
MATCH LINE SHEET 7
MAT
C
H
L
I
N
E
S
H
E
E
T
9
FOR PHASE I EROSION AND SEDIMENT CONTROL ONLY !!
NOTES:
1. SLOPES 3:1 AND GREATER SHALL
BE PROTECTED WITH SOIL
STABILIZATION BLANKETS (EC-2).
2. REFER TO SHEETS 43-44 FOR DITCH
SECTIONS AND COMPUTATIONS
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
630
6
2
0
610
6
2
0
6
1
0
6
0
0
610
60
0
5
9
0
620
6
2
0
620
LCG
LCG
LCG
CI
P
S
F
LCG
S
C
C
SSF
S
S
F
S
S
F
SSF
SSF
SCC
SCC
SCC
DD
DD
GRID
M
E
R
I
D
I
A
N
VA NO
R
T
H
Z
O
N
E
N
A
D
8
3
D
E
S
I
G
N
H
I
G
H
W
A
T
E
R
(1
0
0
Y
R
S
T
O
R
M
)
=
6
1
4
.
6
W
E
T
S
T
O
R
A
G
E
6
1
0
D
R
Y
S
T
O
R
A
G
E
6
1
1
.
5
6
0
6
6
0
8
6
1
0
6
1
2
6
1
4
6
1
6
608
610 612 614 61
6
6
1
1
.
5
614.
6
61
4
61
6
616
614
612 610
608
607
S
E
D
I
M
E
N
T
C
L
E
A
N
O
U
T
L
E
V
E
L
6
0
8
.
7
ROUGH GRADING AND BERM MAY BE
COMPLETED DURING PHASE I/II E&S. FINAL
GRADING AND PLANTS SHALL NOT BE
INSTALLED UNTIL ALL UPSTREAM DRAINAGE
AREAS ARE STABILIZED.
A
R
E
A
1
(
S
E
E
N
A
R
R
A
T
I
V
E
)
A
R
E
A
4
(
S
E
E
N
A
R
R
A
T
I
V
E
)
PROP.
BOULDER
STOCKPILE
A
R
E
A
T
O
S
B
#
1
D
A
=
1
6
.
4
5
A
.
C
.
SILT FENCE MAY BE REMOVED
AFTER STABILIZATION OF STORM
CHANNEL
ES-SEC "1"
ES-SEC "1"
E
X
.
1
5
"
R
C
P
T
O
B
E
R
E
M
O
V
E
D
E
X
I
S
T
I
N
G
C
U
L
V
E
R
T
S
E
M
E
R
G
E
N
C
Y
S
P
I
L
L
W
A
Y
E
L
E
V
A
T
I
O
N
6
1
3
.
5
W
I
D
T
H
1
6
'
X
-
S
E
C
"
1
6
"
X
-
S
E
C
"
1
6
"
S
S
F
DD
T
S
TS
TS
TS
B/M
B/M
B/M
B/M
HAUL ROAD CROSSING
OPERATION (FIGURE TTC-51.0)
PER CURRENT EDITION OF THE
VIRGINIA WORK AREA
PROTECTION MANUAL
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
E&
S
P
H
A
S
E
I
Rev. No. Date
04 09/17/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
1" = 40'
9
06/28/2019
TTC
19-09
59
2760GC
MATCH LINE SHEE
T
7
M
A
T
C
H
L
I
N
E
S
H
E
E
T
8
AREA OF CONCERN - CONTRACTOR TO INVESTIGATE
CONDITIONS FOR STABILITY AND CONSULT WITH A
GEOTECHNICAL ENGINEER FOR STRUCTURAL FILL
REQUIREMENTS SHOULD IT BE DETERMINED AREA IS UNSTABLE
TEMPORARY GRAVEL
CONSTRUCTION ENTRANCE
SUPER SILT FENCE
TEMPORARY DIVERSION DIKE
CULVERT INLET PROTECTION
ROCK CHECK DAMS
SILT FENCE
LIMITS OF CLEARING & GRADING
DRAINAGE DIVIDES
OUTLET PROTECTION
NO. KEY SYMBOL DESCRIPTION
3.09
3.08
3.20
3.05
3.18
3.02
LCG
OP
DD
CIP
SSF
SF
CE
CD
SAFETY FENCE3.01 SAF
3.32 PS PERMANENT SEEDING
IP STORM DRAIN
INLET PROTECTION3.07
3.36 B/M SOIL STABILIZATION
BLANKETS & MATTING
EROSION/SEDIMENT CONTROL LEGEND
STORMWATER
CONVEYANCE CHANNEL3.17 SCC
TEMPORARY SEDIMENT BASIN3.14 SB
3.31 TS TEMPORARY SEEDING
FOR PHASE I EROSION AND SEDIMENT CONTROL ONLY !!
NOTES:
1. SLOPES 3:1 AND GREATER SHALL BE PROTECTED WITH SOIL
STABILIZATION BLANKETS (EC-2).
2. REFER TO SHEETS 43-44 FOR DITCH SECTIONS AND COMPUTATIONS
X
X
X
X
X
X
X
X
X
X
X
6
2
0
SCC
DD
SSF
6
0
6
6
0
8
6
1
0
61
2
614
616
608
610
612
614
616
611
.
5
61
4
.
6
614 616
616
614 61
2
6
1
0
6
0
8
612
614
616
6
1
8
6
1
6
6076
1
4
X-SEC "15"
X-SEC "15"
X
-
S
E
C
"
1
6
"
X
-
S
E
C
"
1
6
"
DESIGN HIGH WATER
(100YR STORM) = 614.6
WET STORAGE
610
DRY STORAGE
611.5
SEDIMENT CLEAN OUT LEVEL
608.7
AREA TO SED TRAP
16.45 ACRES
EMERGENCY
SPILLWAY
ELEVATION 613.5
WIDTH 16'
VDOT CLASS 1
RIPRAP
1' DEEP
W/ FILTER FABRIC
SC 150 LINING OR
APPROVED
EQUIVALENT TS
TS
HAU
L
R
O
A
D
C
R
O
S
S
I
N
G
OPE
R
A
T
I
O
N
(
F
I
G
U
R
E
T
T
C
-
5
1
.
0
)
PER
C
U
R
R
E
N
T
E
D
I
T
I
O
N
O
F
T
H
E
VIRG
I
N
I
A
W
O
R
K
A
R
E
A
PRO
T
E
C
T
I
O
N
M
A
N
U
A
L
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
BA
S
I
N
D
E
T
A
I
L
S
Rev. No. Date
04 09/17/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
1" = 30'
10
06/28/2019
TTC
19-09
59
2760GCFOR PHASE I EROSION AND SEDIMENT CONTROL ONLY !!
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
W W
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
ON
Y
X
D
R
I
V
E
(PR
I
V
A
T
E
A
C
C
E
S
S
)
W
ARV
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
S
S
S
S
S
S
S
S
S
S
S
S
S
S
63
0
640
620
6
2
0
620
6
3
2
62
8
6
3
0
23 68EP
24 58EP 24 60EP 24 60EP 24 60EP 24 60EP 24 60EP 24 60EP
23 30EP 23 68EP 23 68EP 23 68EP 23 68EP
24 60EP
23 30EP 23 30EP 23 30EP
%
2.
0
%
2.
0
%
2.
0 %
2.
8
%
2.
8
%
2.
8
%
2.
8
23 15TOP2315TOP2315TOP2315TOP
%1.0
%1.0
%1.0 %2.0
%2.0
31 00BLDG
31 00BLDG
31 00BLDG
31 00BLDG
31 00BLDG
24 75EP
24 EP
26 40EP
27 00EP
27 00EP
26 45EP
26 40EP
26 40EP
24 93EP
24 75EP
23 30EP
24 66EP
24 90EP
24 90EP 24 25EP
%3.0
%1.0
26 07EP
%
1.
5
%
2.
0
30 13EP 30 13EP
29 10EP
29 46EP
28 74EP2874EP
29 18EP 28 96EP
29 87EP
29 97EP
29 45EP
30 43GND
30 23SW
29 03EP
29 97EP
29 86EP
31 00GND
30 80SW
31 00GND
30 80SW
27 44EP
25 81EP
29 58EP
28 12EP 27 23EP
25 95EP
26 88EP2800GND
27 16EP
29 95GND3033GND
25 65
25 20EP
27 71GND 26 87GND2720GND
30 33GND
29 54GND
29 95GND
30 09SW
27 18GND
28 20HP
30 15SW 28 31GND
27 64GND
27 42GND
30 15GND
01
50
01
50
01
50
01
50
10
00
10
00
10
00
10
00
04
00
10
48
10
48
10
48
10
48
10
48
04
00
04
00
26 35
27 54EP
25 52EP
27 10EP
22 50TOP
26 28HP2471GND2471GND2433GND2433GND2460GND2465GND2465GND
28 00GND
30 33GND3033GND2983GND
24 63GND
25 54GND
24 63GND
30 33GND
31 00GND
29 83GND
30 80GND
30 80GND
30 62GND
30 62GND
29 89GND
29 87GND
29 24GND
30 15
26 83EP
27 16EP
29 81EP
29 99EP2819GND
27 87GND
25 69GND
26 13GND
27 30GND
28 80HP
25 28GND
25 28GND
25 28GND
24 33GND
24 63GND
24 83EP
17 TOP
28 33BP
05
00
05
00
05
00
26 12TOP
30 00
30 00
42 00
40 00
OLR
30 09SW
30 09SW
30 60GND
30 09SW
29 53GND
29 53GND
30 33GND
30 09SW
29 95GND
X-SEC "1"
X-SEC "1"
X-SEC "2"
X-SEC "2"
X-SEC "3"
X-SEC "3"
X-SEC "4"
X-SEC "4"
X-SEC "6"
X-SEC "6"
X-SEC "7"
X-SEC "7"
X-SEC "20"
X-SEC "20"
X-SEC "21"
X-SEC "21"
X-SEC "22"
X-SEC "22"
X-SEC "23"X-SEC "23"
X-SEC "24"
X-SEC "24"
X-SEC "25"X-SEC "25"
X-SEC "28"
X-SEC "28"
X-SEC "26"
X-SEC "26"
X-SEC "5"
X-SEC "5"
X-SEC "27"
X-SEC "27"
610
608
606
604
604
612
608
610
606
6
0
8
6
1
2
6
1
0
612
6
1
2
609
608
.
8
640
642
638
6
3
6
6
3
6
63
8
64
0
6
3
2
6
3
4
6
3
4
6
3
4
6
3
0
6
2
8
6
2
6
63
0
62
2
62
462
2
6
2
6
6
2
8
6
3
0
6
2
0
6
3
6
620
624
630
628
626
628
630
626
624
61
8
616
620
622
624
624622
620
628
628
62
8
63
0
626
628
626
624
630
628 626
624 624
628
626
624
622
622
622
624
624
626
628
628
630
630628
626
62
6
62
6
6
2
4 624
628
626
62
6
62
8
620624
622
626
624
626
60
4
60
6
60
8
61
0
61
4
61
6
60
2
60
2
602
600
603
601
60
3
603602
601.
0
603
601
600
01
50
01
50
01
50
01
50
01
50
01
50
01
50
01
50
B/M
PS
PS
109
111
108
D1
D2
D3
D4
D8
D7
D6
D5
107 106
123
122
103
104
112
RD1
RD2
RD3
RD7
RD8
RD4
RD6
RD5
CC1 CC2 CV4
CV3
CV2
CV1
BC1
BC2
TO STR. 109
DA=0.84 AC.
C=0.35
TO STR. 111
DA=0.48 AC.
C=0.30
TO STR. 108
DA=1.20 AC.
C=0.57
TO STR. RD1
DA=0.11 AC.
C=0.85
TO STR. RD5
DA=0.11 AC.
C=0.85
TO STR. RD2
DA=0.25 AC.
C=0.85
TO RD3
DA=0.25 AC.
C=0.85
TO STR. RD4
DA=0.11 AC.
C=0.85
TO STR. RD6
DA=0.25 AC.
C=0.85
TO STR. RD7
DA=0.25 AC.
C=0.85
TO STR. RD8
DA=0.11 AC.
C=0.85
TO STR. 112
DA=1.11 AC.
C=0.68
TO STR. 123
DA=0.31 AC.
C=0.41
TO STR. CV4
DA=0.31 AC.
C=0.52
TO STR. 103
DA=0.24 AC.
C=0.58
TO STR. 107
DA=0.64 AC.
C=0.79
TO STR. 106
DA=0.67 AC.
C=0.79
GR
I
D
M
E
R
I
D
I
A
N
VA
N
O
R
T
H
Z
O
N
E
N
A
D
8
3
ROU
G
H
G
R
A
D
I
N
G
A
N
D
B
E
R
M
M
A
Y
B
E
COM
P
L
E
T
E
D
D
U
R
I
N
G
P
H
A
S
E
I
/
I
I
E
&
S
.
F
I
N
A
L
GRA
D
I
N
G
A
N
D
P
L
A
N
T
S
S
H
A
L
L
N
O
T
B
E
INS
T
A
L
L
E
D
U
N
T
I
L
A
L
L
U
P
S
T
R
E
A
M
D
R
A
I
N
A
G
E
ARE
A
S
A
R
E
S
T
A
B
I
L
I
Z
E
D
.
TO STR. CC1
DA=0.11 AC.
C=0.77
TO STR. CC2
DA=0.11 AC.
C=0.77
TO STR. 104
DA=0.78 AC.
C=0.76
TO STR. CV5
DA=0.20 AC.
C=0.39
CV5
CV6
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
E&
S
P
H
A
S
E
I
I
Rev. No. Date
06 10/21/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
1" = 40'
11
06/28/2019
TTC
19-09
59
2760GC
MATCH LINE SHEET 12
MAT
C
H
L
I
N
E
S
H
E
E
T
13
AREA OF CONCERN - CONTRACTOR TO INVESTIGATE
CONDITIONS FOR STABILITY AND CONSULT WITH A
GEOTECHNICAL ENGINEER FOR STRUCTURAL FILL
REQUIREMENTS SHOULD IT BE DETERMINED AREA IS UNSTABLE
TEMPORARY GRAVEL
CONSTRUCTION ENTRANCE
SUPER SILT FENCE
TEMPORARY DIVERSION DIKE
CULVERT INLET PROTECTION
ROCK CHECK DAMS
SILT FENCE
LIMITS OF CLEARING & GRADING
DRAINAGE DIVIDES
OUTLET PROTECTION
NO. KEY SYMBOL DESCRIPTION
3.09
3.08
3.20
3.05
3.18
3.02
LCG
OP
DD
CIP
SSF
SF
CE
CD
SAFETY FENCE3.01 SAF
3.32 PS PERMANENT SEEDING
IP STORM DRAIN
INLET PROTECTION3.07
3.36 B/M SOIL STABILIZATION
BLANKETS & MATTING
EROSION/SEDIMENT CONTROL LEGEND
STORMWATER
CONVEYANCE CHANNEL3.17 SCC
TEMPORARY SEDIMENT BASIN3.14 SB
3.31 TS TEMPORARY SEEDING
FOR PHASE II EROSION AND SEDIMENT CONTROL ONLY !!
NOTES:
1. SLOPES 3:1 AND GREATER SHALL BE PROTECTED WITH SOIL
STABILIZATION BLANKETS (EC-2).
2. REFER TO SHEETS 43-44 FOR DITCH SECTIONS AND COMPUTATIONS
3. REFER TO SHEET 50 - VDOT DETAILS FOR OUTLET PROTECTION
COMPS
W W W W W W W W
W
FM
FM
FM
FM
FM
FM
FM
FM
F
M
F
M
W W W W W W W W W W W W
W
FM FM
W
W
W
W
W
E E
E
E
E
E
W
W
W
W
W
W
W
W
W
W
W
ON
Y
X
D
R
I
V
E
(PR
I
V
A
T
E
A
C
C
E
S
S
)
W
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
63
0
630
630
620
6
2
0
6
2
0
26 70EP
29 83EP
30 70BLDG
30 70BLDG
30 70BLDG
30 70BLDG 30 70BLDG 30 70BLDG 30 70BLDG 30 70BLDG 30 70BLDG
%
1.
0
30 70BLDG
30 70BLDG
30 70BLDG
30 70BLDG
30 70BLDG3070BLDG
30 70BLDG
30 70BLDG3070BLDG3070BLDG3070BLDG
26 70EP 26 70EP 26 70EP 26 70EP
26 10EP
26 10EP2610EP
27 00EP 27 00EP
%
1.
0
%
1.
0
%
1.
0
%
1.
0
%
1.
0
%
6.
0
%
9.
8
%
5.
0
29 95EP
29 95EP2670EP
23 68EP
24 58EP
%
2.
0
%
2.
0
%
2.
0
%
2.
0
%
2.
0
%
2.
0
24 60EP 24 60EP 24 60EP 24 60EP 24 60EP 24 60EP
23 30EP 23 68EP 23 68EP 23 68EP 23 68EP
24 60EP
23 30EP 23 30EP 23 30EP
%
2.
0
%
2.
0
%
2.
0 %
2.
8
%
2.
8
%
2.
8
%
2.
8
23 15TOP2315TOP
29 16EP
23 15TOP2315TOP
29 83EP 29 83EP 29 83EP2983EP2983EP2983EP
29 56EP 29 56EP 29 56EP 29 56EP
29 67EP 29 67EP 29 67EP 29 67EP2967EP2967EP2967EP
29 16EP 29 16EP 29 16EP
28 80EP
29 16EP
%
1.
5
28 23LP
28 44EP
28 44EP
%
2.
0
%1.0
%1.0 %2.0
%2.0
31 00BLDG
31 00BLDG
29 83EP 29 83EP
%
1.
5
%
1.
5
%
1.
5
%
1.
5
%
1.
5
%
2.
0
%
2.
0
%
2.
0
%
2.
0
%
2.
0
29 56EP
29 67EP
29 56EP
29 67EP2967EP
29 16EP
30 70GND
30 50SW
30 70GND
28 44EP
30 50SW
30 70GND3013GND
29 93SW 30 50SW
30 70GND
30 50SW
30 13GND
29 93SW
29 16EP
29 56EP
28 80EP2880EP2880EP2880EP2880EP
29 16EP2916EP2916EP2916EP2916EP
28 23LP
28 44EP
28 44EP
28 23LP
28 44EP
28 44EP
28 23LP
28 44EP
28 23LP
28 44EP
28 44EP
28 44EP
28 28LP
28 88EP2888EP
28 88EP2888EP
28 88EP2888EP
28 88EP2888EP2888EP
28 88EP2888EP
29 56EP
29 02EP
29 83EP
24 75EP
24 99EP
26 70EP
30 70BLDG
27 00EP 26 45EP
26 40EP
26 40EP
24 93EP
24 75EP
23 30EP
24 66EP
24 90EP
24 90EP 24 25EP
%3.0
%1.0
25 20EP
01
50
01
50
01
50
01
50
04
00
10
48
10
48
10
48
10
48
10
48
10
48
10
48
04
00
04
00
25 79
26 35
25 57EP
27 54EP
25 97EP
26 05EP
25 52EP
25 80EP
27 10EP
22 50TOP
26 28HP2471GND2471GND2433GND2433GND2460GND2465GND2465GND
28 00GND
30 33GND3033GND2983GND
24 63GND
25 54GND
24 63GND
30 70GND
30 03GND
30 03GND
29 53GND
30 31TOP
30 45GND
30 53GND
30 70GND
30 50TRL
30 46GND
23 29EP
22 88EP
22 83EP
23 40EP
23 08
25 69GND
26 13GND
27 30GND
28 80HP
25 28GND
25 28GND
25 28GND
24 33GND
28 08EP
28 48EP 24 02EP
24 17EP2520EP
24 08EP
25 16EP 23 96EP
30 26TRL 25 76TRL
25 96GND
20 33TOP
23 60GND
26 95TOP 28 10BP
29 02GND
28 39GND
28 51GND
28 10BP
29 02GND
28 39GND
28 51GND
28 10BP
29 02GND
28 39GND
28 51GND
28 10BP
29 02GND
28 39GND
28 51GND
28 10BP
29 02GND
28 39GND
28 51GND
28 10BP
28 95GND
28 39GND
28 51GND
28 51GND
28 51GND2851GND2851GND2851GND
28 39GND
28 51GND
28 14GND
26 95TOP2839GND
28 14GND
26 95TOP2839GND
28 14GND
26 95TOP2839GND
28 14GND
26 95TOP2839GND
28 14GND
26 95TOP2839GND
28 14GND
26 52GND 24 91GND
29 44EP
29 65EP
29 05EP
29 43EP
24 63GND
29 91EP
29 93EP
30 03GND
29 53GND
27 70GND
30 70GND
30 50GND
30 20GND
29 53GND
26 01EP2603EP
25 52EP
25 36EP
24 83EP
26 18EP
26 68EP
27 10EP
27 60EP
28 35EP
28 85EP
29 43EP
28 55EP
29 63CL
28 87CL
29 38EP
29 30CL
28 62EP
29 12EP
26 31GND
17 84TOP
05
00
05
00
05
00
05
00
18 85TOP
21 43BP
%2.3 %2.0 %2.0 %2.0 %2.0 %2.0 %2.0%2.0 %2.0 %2.0 %2.0
29 56EP
29 83EP
42 00
40 00
40 00
34 00
26 00
OLR
OLR
OLR
29 79GND
29 37GND
29 37GND2983GND3003GND
29 53GND
X-SEC "7"
X-SEC "7"
X-SEC "8"
X-SEC "8"
X-SEC "9"X-SEC "9"
X-SEC "10"X-SEC "10"
X-SEC "11"X-SEC "11"
X-SEC "12"
X-SEC "12"
X-SEC "13"
X-SEC "13"
X-SEC "14"X-SEC "14"
X-SEC "15"
X-SEC "15"
X-SEC "16"
X-SEC "16"
X-SEC "17"X-SEC "17"
X-SEC "18"
X-SEC "18"
X-SEC "19"
X-SEC "19"
X-SEC "20"
X-SEC "20"
600
602
600
606
603
608610
612
614
612
612
604
602
640
642
638
6
3
6
6
3
6
63
8
64
0
6
2
6
63
0
62
2
62
4
62
2
6
2
6
6
2
8
6
3
0
6
2
0
6
3
6
63
8
638
63
6
6
3
6
6
3
4
6
3
4
6
3
0
6
2
4
6
2
4
6
2
0
62
4
6
2
8
63
2
63
0
630634 630
63
4
630 628
628
630
630
632
628
620
612
620
626
624
610
620
620
6
1
2
6
2
0
6
1
0
62
0
61
6
62
4
62
6
62
062
2
62
4
62
6
62
8
630
628
620
618
616
614
612
610
622
624
626
620
622
620
624
626
628
626
624
630
628 626
624 624
626626
610
60
8
60
6
6
0
6
60
8
610
610614
624
616
62
6
62
6
6
2
4 624
626
62
6
62
8
620624
622
626
626
626
624
624
624
626
6
2
8
622
602
600
603
601
603602
601.
0
601
600
01
50
01
50
01
50
01
50
01
50
01
50
01
50
01
50
B/M
B/M
PS
PS
B/MPS
100
101
102
D10D11D12D13D14D15
121 120
D22
119
D21 D20
117118
D18
116
115
D16
114
113
110
109
111
108
D1
D2
D7
D6
D5
107 106
103
104
112
D19
D17
RD1
RD2
RD15 RD14 RD13 RD12 RD11 RD10
RD18RD19 RD17RD20RD21RD22 RD16
RD9
RD6
RD5
CC6 CC7 CC8CC5CC4
CC3
TO STR. 109
DA=0.84 AC.
C=0.35
TO STR. 111
DA=0.48 AC.
C=0.30
TO STR. 110
DA=0.74 AC.
C=0.48
TO STR. 121
*DA=0.41 AC.
C=0.55
TO STR. 120
*DA=0.72 AC.
C=0.77
TO STR. 119
*DA=0.76 AC.
C=0.78
TO STR. 113
DA=0.92 AC.
C=0.39
TO STR. 101
DA=0.60 AC.
C=0.43
TO STR. 118
*DA=0.76 AC.
C=0.78
TO STR. 117
*DA=0.76 AC.
C=0.78
TO STR. 116
*DA=0.78 AC.
C=0.78
TO STR. 108
DA=1.20 AC.
C=0.57
TO STR. RD1
DA=0.11 AC.
C=0.85
TO STR. RD5
DA=0.11 AC.
C=0.85
TO STR. RD2
DA=0.25 AC.
C=0.85
TO STR. RD6
DA=0.25 AC.
C=0.85
TO STR. 112
DA=1.11 AC.
C=0.68
TO STR. RD15
DA=0.31 AC.
C=0.85
TO STR. RD14
DA=0.31 AC.
C=0.85
TO STR. RD13
DA=0.31 AC.
C=0.85
TO STR. RD12
DA=0.31 AC.
C=0.85
TO STR. RD11
DA=0.31 AC.
C=0.85
TO STR. RD10
DA=0.31 AC.
C=0.85
TO STR. RD9
DA=0.16 AC.
C=0.85
TO STR. RD22
DA=0.31 AC.
C=0.85
TO STR. RD21
DA=0.31 AC.
C=0.85
TO STR. RD20
DA=0.31 AC.
C=0.85
TO STR. RD19
DA=0.31 AC.
C=0.85
TO STR. RD18
DA=0.31 AC.
C=0.85
TO STR. RD17
DA=0.31 AC.
C=0.85
TO STR. RD16
DA=0.16 AC.
C=0.85
TO STR. 103
DA=0.24 AC.
C=0.58
TO STR. 107
DA=0.64 AC.
C=0.79
TO STR. 106
DA=0.67 AC.
C=0.79
GR
I
D
M
E
R
I
D
I
A
N
VA
N
O
R
T
H
Z
O
N
E
N
A
D
8
3
ROU
G
H
G
R
A
D
I
N
G
A
N
D
B
E
R
M
M
A
Y
B
E
COM
P
L
E
T
E
D
D
U
R
I
N
G
P
H
A
S
E
I
/
I
I
E
&
S
.
F
I
N
A
L
GRA
D
I
N
G
A
N
D
P
L
A
N
T
S
S
H
A
L
L
N
O
T
B
E
INS
T
A
L
L
E
D
U
N
T
I
L
A
L
L
U
P
S
T
R
E
A
M
D
R
A
I
N
A
G
E
ARE
A
S
A
R
E
S
T
A
B
I
L
I
Z
E
D
.
TO STR. 114
*DA=0.64 AC.
C=0.51
TO CC. 3
DA=0.20 AC.
C=0.75
TO CC. 4
DA=0.20 AC.
C=0.75
TO CC. 5
DA=0.20 AC.
C=0.75
TO CC. 6
DA=0.20 AC.
C=0.75
TO CC. 7
DA=0.20 AC.
C=0.75
TO CC. 8
DA=0.22 AC.
C=0.76
TO STR. 114
DA=0.09 AC.
C=0.72
TO STR. 104
DA=0.78 AC.
C=0.76
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
E&
S
P
H
A
S
E
I
I
Rev. No. Date
06 10/21/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
1" = 40'
12
06/28/2019
TTC
19-09
59
2760GC
MATCH LINE SHEET 11
MAT
C
H
L
I
N
E
S
H
E
E
T
13
FOR PHASE II EROSION AND SEDIMENT CONTROL ONLY !!
NOTES:
1. SLOPES 3:1 AND GREATER SHALL BE PROTECTED WITH SOIL
STABILIZATION BLANKETS (EC-2).
2. REFER TO SHEETS 43-44 FOR DITCH SECTIONS AND COMPUTATIONS
3. REFER TO SHEET 50 - VDOT DETAILS FOR OUTLET PROTECTION COMPS
4. DRAINAGE AREAS LABELED (*DA) ARE SIZED PER FUTURE ACREAGE AND
C FACTOR WHICH IS GREATER THAN WHAT IS SHOWN ON THIS PLAN, IN
ORDER TO SIZE THE INLETS FOR FUTURE FLOWS.
W
W
W
W
W
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
W
W
W
F
M
F
M
E
E
E
E
E
E
E
EW
W
W
W
W
W
W
W
W
W
W
W
W
ONYX DRIVE
(PRIVATE ACCESS )
W
A
R
V
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
630
6
2
0
610
6
2
0
6
1
0
6
0
0
610
60
0
5
9
0
620
6
2
0
620
3
0
7
0
B
L
D
G
3
0
7
0
B
L
D
G
3
0
7
0
B
L
D
G
3
0
7
0
B
L
D
G
3
0
7
0
B
L
D
G
3
0
7
0
B
L
D
G
2
6
7
0
E
P
2
6
7
0
E
P
2
6
1
0
E
P
2
6
1
0
E
P
2
7
0
0
E
P
2
7
0
0
E
P
%1.0
%1.0
%6.0
%9.8
%5.0
2
9
9
5
E
P
2
9
9
5
E
P
%2.0
%2.0
%2.0
2
4
6
0
E
P
2
4
6
0
E
P
2
4
6
0
E
P
2
4
6
0
E
P
2
3
6
8
E
P
2
3
6
8
E
P
2
3
6
8
E
P
2
3
3
0
E
P
2
3
3
0
E
P
2
3
3
0
E
P
%2.0
%2.0
%2.8
%2.8
2
3
1
5
T
O
P
2
3
1
5
T
O
P
2
3
1
5
T
O
P
%1.
0
%1.
0
%1.
0
%2.
0
%2.
0
3
1
0
0
B
L
D
G
2
4
7
5
E
P
2
4
9
9
E
P
2
6
7
0
E
P
3
0
7
0
B
L
D
G
2
6
4
0
E
P
2
7
0
0
E
P
2
7
0
0
E
P
2
6
4
5
E
P
2
6
4
0
E
P
2
6
4
0
E
P
2
4
9
3
E
P
2
4
7
5
E
P
2
3
3
0
E
P
2
4
6
6
E
P
2
4
9
0
E
P
2
4
9
0
E
P
2
4
2
5
E
P
%3.
0
%1.
0
2
6
0
7
E
P
2
6
8
8
E
P
2
8
0
0
G
N
D
2
7
1
6
E
P
2
5
6
5
2
5
2
0
E
P
2
7
7
1
G
N
D
2
6
8
7
G
N
D
2
7
2
0
G
N
D
2
8
2
0
H
P
01 50
01 500150
01 50
10 00
10 00
10 00
10 00
04 00
10 48
10 48
10 481048
10 48
10 48 10 48
10 48
10 48
04 000400
2
5
7
9
2
6
3
5
2
5
5
7
E
P
2
7
5
4
E
P
2
5
9
7
E
P
2
6
0
5
E
P
2
5
5
2
E
P
2
5
8
0
E
P
2
7
1
0
E
P
2
2
5
0
T
O
P
2
6
2
8
H
P
2
4
7
1
G
N
D
2
4
7
1
G
N
D
2
4
3
3
G
N
D
2
4
3
3
G
N
D
2
4
6
0
G
N
D
2
4
6
5
G
N
D
2
8
0
0
G
N
D
3
0
3
3
G
N
D
3
0
7
0
G
N
D
3
0
0
3
G
N
D
3
0
0
3
G
N
D
2
9
5
3
G
N
D
3
0
3
1
T
O
P
3
0
4
5
G
N
D
3
0
5
3
G
N
D
3
0
7
0
G
N
D
5
0
T
R
L
3
0
4
6
G
N
D
2
3
2
9
E
P
2
2
8
8
E
P
2
2
8
3
E
P
2
3
4
0
E
P
2
3
0
8
3
0
1
5
2
6
8
3
E
P
2
7
1
6
E
P
2
9
8
1
E
P
2
9
9
9
E
P
2
8
1
9
G
N
D
2
7
8
7
G
N
D
2
5
6
9
G
N
D
2
6
1
3
G
N
D
2
7
3
0
G
N
D
2
8
8
0
H
P
2
5
2
8
G
N
D
2
5
2
8
G
N
D
2
5
2
8
G
N
D
2
4
3
3
G
N
D
2
8
0
8
E
P
2
8
4
8
E
P
2
4
0
2
E
P
2
4
1
7
E
P
2
5
2
0
E
P
2
4
0
8
E
P
2
5
1
6
E
P
2
3
9
6
E
P
3
0
2
6
T
R
L
2
5
7
6
T
R
L
2
5
9
6
G
N
D
2
0
3
3
T
O
P
2
3
6
0
G
N
D
G
N
D
05 00
0500 0500
05 00
05 00
1
8
8
5
T
O
P
2
1
4
3
B
P
07 70
07 70 07 70
07 70
05 90
05 90
07 00
07 00
3
0
0
0
3
0
0
0
2
6
0
0
O
L
R
OLR
2
9
5
3
G
N
D
G
N
D
3
0
0
9
S
W
2
9
7
9
G
N
D
2
9
3
7
G
N
D
2
9
3
7
G
N
D
2
9
8
3
G
N
D
3
0
0
3
G
N
D
2
9
5
3
G
N
D
92 50LP
X-
S
E
C
"
1
6
"
X-
S
E
C
"
1
6
"
X-
S
E
C
"
1
7
"
X-
S
E
C
"
1
7
"
X-
S
E
C
"
1
8
"
X-
S
E
C
"
1
8
"
X-
S
E
C
"
1
9
"
X-
S
E
C
"
1
9
"
X-
S
E
C
"
2
0
"
X-
S
E
C
"
2
0
"
X-
S
E
C
"
2
8
"
X-
S
E
C
"
2
8
"
604
606
600
602
600
606
603
608
610
612
614
612
610
60
2
60
4
60
6
60
8
59
4
592
610 608 606 604
604
612
612
606
604
602
604
603
608
610
606
60
8
61
2
61
0
612
6
1
2
609 608.8
604
606
608
610
610
6
0
4
6
0
6
6
0
8
6
1
0
6
0
2
6
0
0
5
9
8
5
9
6
5
9
4
6
0
6
6
0
8
6
1
0
600
594
610
618
62
0624
610
6
2
0
6
1
2
6
2
0
6
1
0
620
616
624
626
620
622624
626
628
630
628
620
618 616 614 612 610
622
624
626620
622
620624
630 628 626
628
630
6
2
8
626
628
626
6
2
4
62
6
6
2
4
62
6
6
1
0
6
0
8
6
0
6
6
0
6
6
0
8
616
630
630
628
626
626
626
6
2
4
6
2
4
628
62
6
626628
620
624 622
62
6
626
62
6
6
2
4
62
4
624
626
628
622
614
612
610
608
606
604
604
616
606 608610614616
618620
596
598
600
602
600 598
596
602
602
602
600
603
594
594
601
603
603602
601.0
603 601
600
602
601
596
598
600601
602
602.5
5
9
6
5
9
8
6
0
0
6
0
1
6
0
2
6
0
3
6
0
4
593
595
595
5
9
5
595596
601
602.5
01 50
01 50
01 50
01 50
01 50
01 50
01 50
603
01 50
100
10
110
2
D1
0
D1
1
D1
6
11
4
11
3
D8
D7
D6
D5
10
6
10
3
10
411
2
RD
1
1
RD
1
0
RD
1
6
RD
9
RD
6
RD
5
3
2
1
T
O
S
T
R
.
1
1
3
D
A
=
0
.
9
2
A
C
.
C
=
0
.
3
9
T
O
S
T
R
.
1
0
1
D
A
=
0
.
6
0
A
C
.
C
=
0
.
4
3
T
O
S
T
R
.
R
D
1
D
A
=
0
.
1
1
A
C
.
C
=
0
.
8
5
T
O
S
T
R
.
R
D
5
D
A
=
0
.
1
1
A
C
.
C
=
0
.
8
5
T
O
S
T
R
.
R
D
6
D
A
=
0
.
2
5
A
C
.
C
=
0
.
8
5
T
O
S
T
R
.
1
1
2
D
A
=
1
.
1
1
A
C
.
C
=
0
.
6
8
T
O
S
T
R
.
R
D
1
0
D
A
=
0
.
3
1
A
C
.
C
=
0
.
8
5
T
O
S
T
R
.
R
D
9
D
A
=
0
.
1
6
A
C
.
C
=
0
.
8
5
T
O
S
T
R
.
R
D
1
6
D
A
=
0
.
1
6
A
C
.
C
=
0
.
8
5
T
O
S
T
R
.
1
0
3
D
A
=
0
.
2
4
A
C
.
C
=
0
.
5
8
T
O
S
T
R
.
1
0
6
D
A
=
0
.
6
7
A
C
.
C
=
0
.
7
9
ROUGH GRADING AND BERM MAY BE
COMPLETED DURING PHASE I/II E&S. FINAL
GRADING AND PLANTS SHALL NOT BE
INSTALLED UNTIL ALL UPSTREAM DRAINAGE
AREAS ARE STABILIZED.
GRID
M
E
R
I
D
I
A
N
VA NO
R
T
H
Z
O
N
E
N
A
D
8
3
PROP.
BOULDER
STOCKPILE
D
A
=
0
.
0
9
A
C
.
C
=
0
.
7
2
T
O
S
T
R
.
1
0
4
D
A
=
0
.
7
8
A
C
.
C
=
0
.
7
6
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
E&
S
P
H
A
S
E
I
I
Rev. No. Date
04 09/17/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
1" = 40'
13
06/28/2019
TTC
19-09
59
2760GC
MATCH LINE SHEE
T
12
M
A
T
C
H
L
I
N
E
S
H
E
E
T
1
1
AREA OF CONCERN - CONTRACTOR TO INVESTIGATE
CONDITIONS FOR STABILITY AND CONSULT WITH A
GEOTECHNICAL ENGINEER FOR STRUCTURAL FILL
REQUIREMENTS SHOULD IT BE DETERMINED AREA IS UNSTABLE
TEMPORARY GRAVEL
CONSTRUCTION ENTRANCE
SUPER SILT FENCE
TEMPORARY DIVERSION DIKE
CULVERT INLET PROTECTION
ROCK CHECK DAMS
SILT FENCE
LIMITS OF CLEARING & GRADING
DRAINAGE DIVIDES
OUTLET PROTECTION
NO. KEY SYMBOL DESCRIPTION
3.09
3.08
3.20
3.05
3.18
3.02
LCG
OP
DD
CIP
SSF
SF
CE
CD
SAFETY FENCE3.01 SAF
3.32 PS PERMANENT SEEDING
IP STORM DRAIN
INLET PROTECTION3.07
3.36 B/M SOIL STABILIZATION
BLANKETS & MATTING
EROSION/SEDIMENT CONTROL LEGEND
STORMWATER
CONVEYANCE CHANNEL3.17 SCC
TEMPORARY SEDIMENT BASIN3.14 SB
3.31 TS TEMPORARY SEEDING
FOR PHASE II EROSION AND SEDIMENT CONTROL ONLY !!
NOTES:
1. SLOPES 3:1 AND GREATER SHALL BE PROTECTED WITH SOIL
STABILIZATION BLANKETS (EC-2).
2. REFER TO SHEETS 43-44 FOR DITCH SECTIONS AND COMPUTATIONS
3. REFER TO SHEET 50 - VDOT DETAILS FOR OUTLET PROTECTION COMPS
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
E&
S
N
A
R
R
A
T
I
V
E
Rev. No. Date
04 09/17/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
AS SHOWN
14
06/28/2019
TTC
19-09
59
2760GC
EROSION AND SEDIMENT
CONTROL NARRATIVE
Description: The project development proposes construction of five industrial warehouses, with related
utilities, parking, and private roadways which shall be completed over three separate project phases. This
plan consists of phase I which proposes the construction of two industrial warehouses, (Buildings 1 & 2)
with related utilities, parking and the construction of approximately 1,477 feet of private drive which ties
into the existing stub road connection to Snowden Bridge Boulevard. Water and sanitary sewer
connections are located off Snowden Bridge Boulevard. Building 1 is the only building which utilizes a
gravity sanitary sewer connection. All other proposed buildings will utilize a private sanitary force main and
grinder pumps to meet sanitary demands. Offsite drainage areas will be bypassed around the disturbed
areas by diversions, channels and culverts to isolate the construction areas.
The property, zoned M1, is located at the current end of Snowden Bridge Boulevard on the north side near
the intersection of Milburn Road and is located in Frederick County, Virginia. The project is currently
shown impacting two parcels, however the property line seperating the two will be vacated/relocated and a
portion of one parcel is to be consolidated into the other for a total site area of 80.44 acres, of which
approximately 37.87 acres will be disturbed for construction.
Date of construction: Construction of Phase I will begin following plan approval and will take
approximately twelve (12) months to complete. Phase II and Phase III will be constructed at a later date.
Existing site conditions: The site is currently pasture with a rolling terrain and minimal wooded areas.
Majority of the site drains to the center of the property and then east. A small portion of the property
drains to the north. All areas drain to Hiatt Run which are tributaries to the Potomac River. Typical slopes
range between 2% and 50%.
Adjacent areas: The site is bounded on the north by McCann's Road (RT 838) and by vacant parcels
zoned RA. Bounded on the east by Milburn Road (RT 662) and to the northeast by residential property
zoned RA and to the southeast by vacant property zoned R4. To the south is Snowden Bridge Boulevard
and vacant parcels zoned M1. The site is bounded on the west by the CSX Railroad and vacant properties
zoned OMRA & M1.
Offsite areas: Topsoil will be stripped from graded areas and stockpiled for use in final grading and
permanent stabilization. Stockpiles will be kept either onsite or offsite on adjacent land owned by the
developer to stay clear of all construction activities. The stockpiles will be stabilized with temporary
seeding and protected with silt fence. Additional adjacent offsite area will be used as a borrow area to
obtain additional fill material.
Soils: The existing soil conditions were obtained from the USDA Soils Survey. The soils on this site
consist mostly different types of silt loam as shown on the map on this sheet.
Areas of Concern: There are areas of concern associated with this plan. There are several depressions
on site that may be part of Karst areas or sink holes that will require a geotechnical analysis on how to
remediate. Additionally there are wetland areas that have an existing permit at the offsite barrow area.
Impacts at those crossings should be kept to a minimum.
Erosion And Sediment Control Measures: Unless otherwise indicated, all vegetative and structural erosion
and sediment control measures shall be constructed and maintained according to the minimum standards
and specifications of the Virginia Erosion and Sediment Control Handbook.
Structural Measures:
E&S Phase I:
During phase I there are 4 areas that need to be constructed first before installing the sediment basin prior
to clearing and grubbing operations. This is necessary to divert as much offsite water around the
construction areas as possible. The twin elliptical culverts and associated ditch that cross Milburn road
need to be installed first (Area 1). Second the beginning of Graystone Drive needs to be constructed up to
the proposed box culvert crossing and the box culvert needs to be installed (Area 2). The road, ditches
and diversions need to be stabilized immediately after construction. After installing the road and box
culvert complete the diversions and ditches shown as area 2. Next complete the ditch and diversion shown
as Area 3 and then the channel bypass shown as Area 4.
Install Safety Fence (3.01) as shown on the plans to prevent access to critical areas.
Install Temporary Construction Entrance with Wash Rack (3.02) at the entrance to the site on Snowden
Bridge Blvd.
Install Silt Fence (3.05) and Super Silt Fence as shown on the plans to intercept and detain small amounts
of sediment from disturbed areas during construction in order to prevent sediment from leaving the site.
Smart Fence may be used in lieu of Super Silt Fence and compost filter sock in lieu of silt fence.
Culvert inlet protection (3.08) shall be located at culvert entrances as shown to prevent sediment from
entering, accumulating in and being transferred by the culvert prior to permanent stabilization of the
disturbed area.
Install temporary diversion dikes (3.09) as shown on the plans to divert sediment-laden runoff to the
sediment trapping structures.
Install Temporary Sediment Basin (3.14) as shown on plans to detain sediment-laden runoff from
disturbed areas in "wet" and "dry" storage long enough for the majority of the sediment to settle out.
Install Stormwater Conveyance Channel (3.17) as shown to provide for the conveyance of concentrated
surface runoff water to a receiving channel or system without damage from erosion.
Outlet protection (3.18) shall be installed on all outlets as shown on the plan sheets.
Install rock check dams (3.20) as shown on the plans to reduce the velocity of concentrated stormwater
flows and to trap sediment generated from adjacent areas or the ditch itself.
Temporary seeding (3.31) and/or permanent seeding (3.32) shall be placed on all critical slopes (3:1 or
greater) and as needed to stabilize disturbed areas.
Soil stabilization blankets & matting (3.36) shall be installed over steep 3:1 or greater cut and fills slope
which have been brought to final grade and seeded to protect from rill and gully erosion.
E&S Phase II:
Phase I controls shall remain into Phase II for the duration of the project or until drainage area is
stabilized.
Install storm drain inlet protection (3.07) as shown on plans to prevent sediment from entering storm
drainage systems prior to permanent stabilization of the disturbed area.
Install inlet and outlet protection measures as stormwater structures are installed.
Fill slope surface shall be left in a roughened condition to reduce erosion, see Plate 3.29-4. Contractor
shall redirect the concentrated flow away from the fill slope by installing diversion dike and divert the runoff
to sediment traps or sediment basins.
Temporary seeding (3.31) and/or permanent seeding (3.32) shall be placed on all critical slopes (3:1 or
greater) and as needed to stabilize disturbed areas.
* BMPs shall not be installed until their respective drainage area is completed and full stabilized.
Vegetative Measures:
Permanent or temporary soil stabilization shall be applied to denuded areas within seven (7) days after
final grade is reached on any portion of the site. Temporary soil stabilization shall be applied within seven
(7) days to denuded areas that may not be at final grade but will remain dormant for longer than fourteen
(14) days. Permanent soil stabilization shall be applied to all areas that are to be left dormant for more
than six (6) months.
Topsoil that has been stockpiled shall be surrounded with silt fence and protected by mulch and/or
temporary vegetation immediately after grading.
All earth berms, diversions and sediment trap embankments are to be machine-compacted, seeded and
mulched (hay mulch or straw) for temporary and/or permanent vegetative cover immediately after
construction
Erosion control mats shall be installed over steep (3:1) cut and fills slope which have been brought to final
grade and seeded to protect from rill and gully erosion.
Management Strategies:
Construction shall be sequenced such that grading operations will begin and end as quickly as
possible.
The site superintendent shall be responsible for the installation and maintenance of all erosion and
sediment control measures. Maintenance of these measures throughout the project is critical to the
effectiveness of the program.
After areas above controls have been stabilized, the controls shall be cleaned up and removed.
Electric power, telephone, storm, sanitary, water & gas supply trenches are to be compacted,
seeded and mulched within five (5) days after backfilling. No more than 500 feet are to be open at
any one time.
All cut and fill slopes are to be seeded and mulched within five (5) days of completion of grading.
Drainage swales shall be stabilized with check dams until vegetation has been well established, at
which time the check dams shall be removed.
Devices listed above are considered minimum erosion and sediment controls. Additional control
measures may be necessary due to contractor phasing or other unforeseen conditions. It is the
contractor's responsibility to provide additional measures to those shown, as needed, in order to
control erosion and contain sediment on site. All measures shall be installed according to the
standards and specifications in the Virginia Erosion and Sediment Control Handbook.
Stormwater Management:
Increased runoff from this development will be controlled by the Project's stormwater management
facilities (See sheets 31 - 35).
Maintenance Program:
All control measures shall be inspected daily by the site superintendent or his representative and
within 24 hours after any storm event greater than 0.5 inches of rain per 24-hour period. Any
damaged structural measures are to be repaired by the end of the day. Seeded areas shall be
checked regularly to ensure that a good stand of grass is maintained. All areas shall be fertilized
and re-seeded as needed until grass is established.
Trapped sediment is to be removed as required to keep below the clean out level specified
disposed of by spreading on site.
Inlet protection shall be checked regularly for sediment build-up. If the gravel outlet is clogged by
sediment, it shall be removed and cleaned or replaced immediately.
The contractor is responsible for keeping existing public roads in a clean, dust and mud free,
condition at all times.
Erosion and sediment control program:
Phase I
1. Hold pre-construction meeting on site with inspector.
2. Install construction entrance.
3. Install areas 1 - 4 in consecutive order
4. Clearing and grubbing for placement of sediment control devices only.
5. Obtain inspector's approval prior to beginning grading operations.
6. Clear and grub main area of site protected by installed E&S controls.
Phase II
7. Rough grade remainder of site.
8. Install drainage devices with sediment control.
9. Final grading.
10. Restoration and stabilization of disturbed areas.
11. Remove erosion and sediment control measures with the approval of the inspector.
Note: The Frederick County Public Works and Engineering Department retain the right to add
and/or modify these erosion and sediment control measures during the construction process,
within reason, to ensure adequate protection to the public and the environment.
Seeding schedule (soil stabilization):
1. All permanent seeding shall be in accordance with section 3.31 & 3.32 of the VESCH.
2. Spread topsoil at a minimum depth of four (4) inches.
3. Incorporate pulverized agricultural limestone into the topsoil at a rate of 92 lbs. per 1,000
square feet (2 tons per acre).
4. Fertilize with 10-10-10 fertilizer at a rate of 23 lbs per 1,000 square feet (1,000 lbs per acre).
5. Seed all areas with a seed mix consisting of 67% Kentucky 31 Tall Fescue and 33% Red Top
Clover.
6. Mulch all seeded areas with straw mulch applied at a rate of 3,500 lbs per acre anchored with
cutback or emulsified asphalt applied at a rate of 200 gallons per acre.
Dust control:
1. Temporary seeding shall be applied to all disturbed areas subject to little or no construction
traffic.
2. All haul roads and other heavy traffic routes shall be sprinkled with water until the surface is
wet and repeated as needed to control dust.
VARIANCE REQUEST - SMARTFENCE & COMPOST FILTER SOCK:
We are requesting the use of an alternative erosion and sediment control measures that is not
listed in the Virginia Erosion and Sediment Control Handbook.
1. ACF Environmental - Smartfence: Smartfence is an perimeter erosion control device
equivalent to super silt fence, see detail on sheet 15.
2. Filtrexx - Compost Filter Sock: Compost filter sock is equivalent to silt fence, see detail on
sheet 15. This will allow for less disturbance since it can be installed on the surface and
requires no excavation.
MINIMUM CONSTRUCTION STANDARDS
An erosion and sediment control program adopted with this plan must be consistent with
the VSECH for 9VAC25-840-40 minimum standards:
1. Permanent or temporary soil stabilization shall be applied to denuded areas within
seven days after final grade is reached on any portion of the site. Temporary soil
stabilization shall be applied within seven days to denuded areas that may not be at
final grade but will remain dormant for longer than 14 days. Permanent stabilization
shall be applied to areas that are to be left dormant for more than one year.
2. During construction of the project, soil stock piles and borrow areas shall be stabilized
or protected with sediment trapping measures. The applicant is responsible for the
temporary protection and permanent stabilization of all soil stockpiles on site as well
as borrow areas and soil intentionally transported from the project site.
3. A permanent vegetative cover shall be established on denuded areas not otherwise
permanently stabilized. Permanent vegetation shall not be considered established
until a ground cover is achieved that is uniform, mature enough to survive and will
inhibit erosion.
4. Sediment basins and traps, perimeter dikes, sediment barriers and other measures
intended to trap sediment shall be constructed as a first step in any land-disturbing
activity and shall be made functional before upslope land disturbance takes place.
5. Stabilization measures shall be applied to earthen structures such as dams, dikes
and diversions immediately after installation.
6. Sediment traps and sediment basins shall be designed and constructed based upon
the total drainage area to be served by the trap or basin.
a. The minimum storage capacity of a sediment trap shall be 134 cubic yards per acre
of drainage area and the trap shall only control drainage areas less than three acres.
b. Surface runoff from disturbed areas that is comprised of flow from drainage areas
greater than or equal to three acres shall be controlled by a sediment basin. The
minimum storage capacity of a sediment basin shall be 134 cubic yards per acre of
drainage area. The outfall system shall, at a minimum, maintain the structural integrity
of the basin during a 100-year storm of 24-hour duration. Runoff coefficients used in
runoff calculations shall correspond to a bare earth condition or those conditions
expected to exist while the sediment basin is utilized.
7. Cut and fill slopes shall be designed and constructed in a manner that will minimize
erosion. Slopes that are found to be eroding excessively within one year of
permanent stabilization shall be provided with additional slope stabilizing measures
until the problem is corrected.
8. Concentrated runoff shall not flow down cut or fill slopes unless contained within an
adequate temporary or permanent channel, flume or slope drain structure.
9. Whenever water seeps from a slope face, adequate drainage or other protection shall
be provided.
10. All storm sewer inlets that are made operable during construction shall be protected
so that sediment-laden water cannot enter the conveyance system without first being
filtered or otherwise treated to remove sediment.
11. Before newly constructed stormwater conveyance channels or pipes are made
operational, adequate outlet protection and any required temporary or permanent
channel lining shall be installed in both the conveyance channel and receiving
channel.
12. When work in a live watercourse is performed, precautions shall be taken to minimize
encroachment, control sediment transport and stabilize the work area to the greatest
extent possible during construction. Nonerodible material shall be used for the
construction of causeways and cofferdams. Earthen fill may be used for these
structures if armored by nonerodible cover materials.
13. When a live watercourse must be crossed by construction vehicles more than twice in
any six-month period, a temporary vehicular stream crossing constructed of
nonerodible material shall be provided.
14. All applicable federal, state and local requirements pertaining to working in or
crossing live watercourses shall be met.
15. The bed and banks of a watercourse shall be stabilized immediately after work in the
watercourse is completed.
16. Underground utility lines shall be installed in accordance with the following standards
in addition to other applicable criteria:
a. No more than 500 linear feet of trench may be opened at one time.
b. Excavated material shall be placed on the uphill side of trenches.
c. Effluent from dewatering operations shall be filtered or passed through an approved
sediment trapping device, or both, and discharged in a manner that does not
adversely affect flowing streams or off-site property.
d. Material used for backfilling trenches shall be properly compacted in order to
minimize erosion and promote stabilization.
e. Restabilization shall be accomplished in accordance with this chapter.
f. Applicable safety requirements shall be complied with.
17. Where construction vehicle access routes intersect paved or public roads, provisions
shall be made to minimize the transport of sediment by vehicular tracking onto the
paved surface. Where sediment is transported onto a paved or public road surface,
the road surface shall be cleaned thoroughly at the end of each day. Sediment shall
be removed from the roads by shoveling or sweeping and transported to a sediment
control disposal area. Street washing shall be allowed only after sediment is removed
in this manner. This provision shall apply to individual development lots as well as to
larger land-disturbing activities.
18. All temporary erosion and sediment control measures shall be removed within 30
days after final site stabilization or after the temporary measures are no longer
needed, unless otherwise authorized by the VESCP authority. Trapped sediment and
the disturbed soil areas resulting from the disposition of temporary measures shall be
permanently stabilized to prevent further erosion and sedimentation.
19. Properties and waterways downstream from development sites shall be protected
from sediment deposition, erosion and damage due to increases in volume, velocity
and peak flow rate of stormwater runoff for the stated frequency storm of 24-hour
duration in accordance with the following standards and criteria. Stream restoration
and relocation projects that incorporate natural channel design concepts are not
man-made channels and shall be exempt from any flow rate capacity and velocity
requirements for natural or man-made channels:
a. Concentrated stormwater runoff leaving a development site shall be discharged
directly into an adequate natural or man-made receiving channel, pipe or storm sewer
system. For those sites where runoff is discharged into a pipe or pipe system,
downstream stability analyses at the outfall of the pipe or pipe system shall be
performed.
b. Adequacy of all channels and pipes shall be verified in the following manner:
(1) The applicant shall demonstrate that the total drainage area to the point of analysis
within the channel is one hundred times greater than the contributing drainage
area of the project in question; or
(2) (a) Natural channels shall be analyzed by the use of a two-year storm to verify that
stormwater will not overtop channel banks nor cause erosion of channel bed or
banks.
(b) All previously constructed man-made channels shall be analyzed by the use of
a 10-year storm to verify that stormwater will not overtop its banks and by the
use of a two-year storm to demonstrate that stormwater will not cause erosion
of channel bed or banks; and
(c) Pipes and storm sewer systems shall be analyzed by the use of a 10-year
storm to verify that stormwater will be contained within the pipe or system.
c. If existing natural receiving channels or previously constructed man-made channels
or pipes are not adequate, the applicant shall:
(1) Improve the channels to a condition where a 10-year storm will not overtop the
banks and a two-year storm will not cause erosion to the channel, the bed, or the
banks; or
(2) Improve the pipe or pipe system to a condition where the 10-year storm is
contained within the appurtenances;
(3) Develop a site design that will not cause the pre-development peak runoff rate
from a two-year storm to increase when runoff outfalls into a natural channel or will
not cause the pre-development peak runoff rate from a 10-year storm to increase
when runoff outfalls into a man-made channel; or
(4) Provide a combination of channel improvement, stormwater detention or other
measures which is satisfactory to the VESCP authority to prevent downstream
erosion.
d. The applicant shall provide evidence of permission to make the improvements.
e. All hydrologic analyses shall be based on the existing watershed characteristics and
the ultimate development condition of the subject project.
f. If the applicant chooses an option that includes stormwater detention, he shall obtain
approval from the VESCP of a plan for maintenance of the detention facilities. The
plan shall set forth the maintenance requirements of the facility and the person
responsible for performing the maintenance.
g. Outfall from a detention facility shall be discharged to a receiving channel, and
energy dissipators shall be placed at the outfall of all detention facilities as necessary to
provide a stabilized transition from the facility to the receiving channel.
h. All on-site channels must be verified to be adequate.
i. Increased volumes of sheet flows that may cause erosion or sedimentation on
adjacent property shall be diverted to a stable outlet, adequate channel, pipe or pipe
system, or to a detention facility.
j. In applying these stormwater management criteria, individual lots or parcels in a
residential, commercial or industrial development shall not be considered to be separate
development projects. Instead, the development, as a whole, shall be considered to be a
single development project. Hydrologic parameters that reflect the ultimate development
condition shall be used in all engineering calculations.
k. All measures used to protect properties and waterways shall be employed in a
manner which minimizes impacts on the physical, chemical and biological integrity of
rivers, streams and other waters of the state.
l. Any plan approved prior to July 1, 2014, that provides for stormwater management
that addresses any flow rate capacity and velocity requirements for natural or man-made
channels shall satisfy the flow rate capacity and velocity requirements for natural or
man-made channels if the practices are designed to (i) detain the water quality volume
and to release it over 48 hours; (ii) detain and release over a 24-hour period the expected
rainfall resulting from the one year, 24-hour storm; and (iii) reduce the allowable peak flow
rate resulting from the 1.5, 2, and 10-year, 24-hour storms to a level that is less than or
equal to the peak flow rate from the site assuming it was in a good forested condition,
achieved through multiplication of the forested peak flow rate by a reduction factor that is
equal to the runoff volume from the site when it was in a good forested condition divided
by the runoff volume from the site in its proposed condition, and shall be exempt from any
flow rate capacity and velocity requirements for natural or man-made channels as defined
in any regulations promulgated pursuant to § 62.1-44.15:54 or 62.1-44.15:65 of the Act.
m. For plans approved on and after July 1, 2014, the flow rate capacity and velocity
requirements of § 62.1-44.15:52 A of the Act and this subsection shall be satisfied by
compliance with water quantity requirements in the Stormwater Management Act (§
62.1-44.15:24 et seq. of the Code of Virginia) and attendant regulations, unless such
land-disturbing activities are in accordance with 9VAC25-870-48 of the Virginia
Stormwater Management Program (VSMP) Regulation or are exempt pursuant to
subdivision C 7 of § 62.1-44.15:34 of the Act.
n. Compliance with the water quantity minimum standards set out in 9VAC25-870-66
of the Virginia Stormwater Management Program (VSMP) Regulation shall be deemed to
satisfy the requirements of this subdivision 19.
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
E&
S
D
E
T
A
I
L
S
Rev. No. Date
04 09/17/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
N/A
15
06/28/2019
TTC
19-09
59
2760GC
2" X 2" X 36" WOODEN STAKES PLACED 10' O.C.
SECTION NTS
PLAN NTS
NOTES:
1. ALL MATERIAL TO MEET FILTREXX® SPECIFICATIONS.
2. FILTER MEDIA™ FILL TO MEET APPLICATION
REQUIREMENTS.
3. COMPOST MATERIAL TO BE DISPERSED ON SITE, AS
DETERMINED BY ENGINEER.
12" MIN
FILTREXX® SEDIMENT CONTROL
NTS
FILTREXX® SOXX™ (12" TYPICAL)
BLOWN/PLACED FILTER MEDIA™
AREA TO BE PROTECTEDWORK AREA
WORK AREA
AREA TO BE
PROTECTED
2" X 2" X 36" WOODEN STAKES PLACED 10' O.C.
FILTREXX® SOXX™ (12" TYPICAL)
WATER FLOW
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
E&
S
D
E
T
A
I
L
S
Rev. No. Date
04 09/17/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
PH
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
N/A
16
06/28/2019
TTC
19-09
59
2760GC
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
X X
X
X
X
X
X
X X X X X X X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
1
6
6
3
6
.
3
1
3
9
6
5
9
.
3
4
S
S
S
S
S
S
S
S
S
W
W
W
FM
FM FM
FM FM
FM
W
W
W
W
W
W
W
W
E
E
E
E
E E
E
E
S
W W W
W W
W
A
R
V
GRID M
E
R
I
D
I
A
N
VA NO
R
T
H
Z
O
N
E
N
A
D
8
3
BUILDING #2
PROP. WAREHOUSE FACILITY
175,760 SF
APPROX. FFE = 630.70
BUILDING #1
PROP. WAREHOUSE
FACILITY
63,000 SF
APPROX. FFE = 631.00
SWM RETENTION
POND
E
X
.
V
D
O
T
R
.
O
.
W
.
E
X
.
V
D
O
T
R
.
O
.
W
.
E
X
.
V
D
O
T
R
.
O
.
W
.
E
X
.
T
R
A
I
L
E
X
.
T
R
A
I
L
ONYX
D
R
I
V
E
(PRIVA
T
E
A
C
C
E
S
S
)
ONYX DRIVE
(PRIVATE ACCESS)
603
.
6
'
4
7
1
.
7
7
'
663.01'
106
9
.
5
'
7
2
6
.
9
5
'
162.98
'
1
7
2
.
5
7
'
1
7
3
.
7
8
'
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
OV
E
R
A
L
L
G
E
O
M
E
T
R
Y
&
G
R
A
D
I
N
G
P
L
A
N
Rev. No. Date
02 08/16/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
1" = 100'
17
06/28/2019
TTC
19-09
59
2760GC
SHE
E
T
S
18 , 21 & 24
SHE
E
T
S
19 , 22 & 25
SHEETS 20, 23 & 26
11
13
911
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
W W
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
ON
Y
X
D
R
I
V
E
(PR
I
V
A
T
E
A
C
C
E
S
S
)
30
0
'
210'
BUILDING #1
PROP. WAREHOUSE FACILITY
63,000 SF
APPROX. FFE = 631.00
12' CONC DOLLY PAD (SEE NOTE)
11'
TYP
MAIN OFFICE
SPACE (1,000 S.F.)
18
'
18
'
24
'10'
TYP
CG-6R
CG-6
R=5
'
R=
5
'
5' S/W
75
'
75
'
75
'
75
'
5.5'X5.5' CONCRETE
PAD (TYP)
R
=
5
0
'
R=1
0
'
60
'
C
O
N
C
L
O
A
D
I
N
G
D
O
C
K
13
.
5
'
TY
P
75' TYP
R=50'
R=
2
5
'
12
'
C
O
N
C
D
O
L
L
Y
P
A
D
(
S
E
E
N
O
T
E
)
55' TYP
11
'
TY
P
R
=
5
0
'
R=50'
R=
2
5
'
R=62
'
R=5
'
R=
5
'
4'
20
'
25
'
23
.
9
'
23
.
9
'
40'
8' A
S
P
H
A
L
T
T
R
A
I
L
8' A
S
P
H
A
L
T
T
R
A
I
L
8' A
S
P
H
A
L
T
T
R
A
I
L
48
'
T
Y
P
CG-6TF
55
'
T
R
A
I
L
E
R
P
A
R
K
I
N
G
CG
-
6
T
CURB TRANSITION
CG-6R TO CG-6
GC-12B
CURB
TRANSITION
CG-6R TO CG-6
LOADING DOCK
DOOR (TYP)
LIGHT FIXTURE
(TYP)
ACCESS STAIRS
(TYP)
CG-6T CG-6T
CG-6
C
G
-
6
T
REVISED
TREELINE
(TYP)
LIMITS OF
DISTURBANCE
(TYP)
LIGHT FIXTURE
(TYP)
8' ASPHALT
T
R
A
I
L
TIE INTO
EX. TRAIL
TIE INTO EX. STUB
(SEE PAVEMENT
PLAN NOTE)
CG-6T
5.5'X5.5' CONCRETE
PAD (TYP)
CG-6
R=25'
CONC SCUPPER SEE
DETAIL SHEET 47
10'
TYP
8' SHOULDER
4' GRAVEL/
4' GRASS
(TYP)
60' TYP
14
.
3
1
'
69.78'20'120.22'
W
ARV
PROP
BOLLARD
(TYP)
DUMPSTER
5' CROSSWALK
PROPOSED PICNIC AREA
21.0' x 22.4' -
4" CL A3 CONCRETE PAD
W/WELDED WIRE FABRIC
(SEE NOTE 6)
21'
2
2
.
4
'
5'
S
/
W
TIE INTO EX. STUB
(SEE PAVEMENT
PLAN NOTE)
20'
19'TIE INTO
EX. TRAIL
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
S
S
S
S
S
S
S
S
S
S
S
S
S
S
GR
I
D
M
E
R
I
D
I
A
N
VA
N
O
R
T
H
Z
O
N
E
N
A
D
8
3
11' CROSSWALK
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
GE
O
M
E
T
R
Y
P
L
A
N
Rev. No. Date
04 09/17/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
1" = 40'
18
06/28/2019
TTC
19-09
59
2760GC
MATCH LINE SHEET 19
MAT
C
H
L
I
N
E
S
H
E
E
T
20
NOTES:
1. TRACTOR TRAILER DOLLY PADS ARE SHOWN AT 7' BACK FROM THE FRONT OF THE SPACE AND WITH A
12' CONCRETE WIDTH. CONTRACTOR SHALL CONFIRM LOCATION WITH THE OWNER/DEVELOPER PRIOR
TO CONSTRUCTION TO ENSURE LOCATION IS ACCEPTABLE.
2. PROPOSED BUILDING MOUNTED SIGNS SHALL BE REVIEWED AND APPROVED WITH THE FREDERICK
COUNTY BUILDING PERMIT. ANY BUSINESS SIGNS (FREESTANDING OR MONUMENT) SHALL BE
REVIEWED AND APPROVED BY FREDERICK COUNTY PLANNING DEPARTMENT PRIOR TO INSTALLATION.
3. POWER, COMMUNICATIONS AND GAS UTILITIES ARE SHOWN HERE FOR REFERENCE PURPOSES IN
COORDINATION OF CONSTRUCTION. DESIGN OF THESE SYSTEMS ARE BY THE RESPECTIVE UTILITY
COMPANY PROVIDING THE SERVICE. IF ANY CONFLICTS BETWEEN THE CIVIL PLANS AND THE UTILITY
COMPANY PLANS, THE ENGINEER MUST BE NOTIFIED IMMEDIATELY TO DETERMINE THE BEST COURSE
OF ACTION.
4. CROSS WALKS SHALL BE TYPE A CLASS I WHITE PAVEMENT MARKING. LONGITUDINAL LINES SHOULD BE
12 TO 24 INCHES WIDE AND SEPARATED BY GAPS OF 12 TO 60 INCHES. THE DESIGN OF THE LINES
SHOULD AVOID THE WHEEL PATHS IF POSSIBLE, AND THE GAP BETWEEN THE LINES SHOULD NOT
EXCEED 2.5 TIMES THE WIDTH OF THE LONGITUDINAL LINES.
5. CROSSWALK SYMBOLS SHOWN ON THE PLAN ARE TO SHOW THE LOCATION OF THE PROPOSED
CROSSWALKS. CROSSWALK MARKINGS ARE TO BE LONGITUDINAL WITH THE FLOW OF TRAFFIC AND
SHOULD MATCH THE EXISTING CROSSWALK MARKINGS IN THE INDUSTRIAL CENTER IF APPLICABLE.
6. OWNER TO INSTALL 4 PICNIC TABLES PER A BUILDING WITHIN 30 DAYS OF OCCUPANCY FOR EMPLOYEE
USE.
INSPECTION NOTES
1. Buildings shall comply with The Virginia Uniform Statewide Building Code (VUSBC) Sections 311, S Storage of the International Building Code/2105 VUSBC/
International Fire Code. Other Code that applies is ICC A 117.1-3-09. Accessible and Usable Buildings and Facilities and 2015 Virginia Energy Code
2. Proposed buildings shall comply with height and area per T504 for type of construction or unlimited area facilities (Section 507, Unlimited Area Buildings) and
maintain an open perimeter of 60'. Fire pump shall meet NFPA 20.
3. All required exits shall meet ANSI A117.1-09 for accessibility and slopes. Maximum travel distance per IBC/USB to an exit is 400'. All required exits shall be
accessible. Exterior area of assisted rescue shall comply with Section 1016 of the USBC/IBC. One hour rated walls with 45 min. doors shall be provided at
exterior areas of assisted rescue as noted. Maximum travel distance to restrooms shall be in accordance with Section 2902.3.2. (Maximum 500' unless otherwise
approved by AHJ)
4. Storage in racks exceeding 12' in height require a permit and shall comply with the International Fire Code. High pile storage areas require fire department
access around perimeter of the building. Access/doors shall not be spaced further apart than 100'.
5. ANSI parking spaces shall be provided as required per T1106.1. Accessible parking and unloading shall not exceed 2% slope (1:48). Accessible Route shall
extend from parking and unloading area to accessible route to main entrance. Curb ramps shall have a minimum 3' landing at the top and bottom of the landing.
Van spaces require minimum unloading area 8' with 8' of parking or a minimum of 11' wide parking with 5' of unloading space is required. No enlargement
provided. Accessible route with max 5% slopes shall be provided from parking/unloading to main entrance. Accessible parking and unloading access to main
entrance appears to meet ANSI A 117 for slopes.
6. Public entrances into spaces larger than 3000 sq ft shall be provided with a vestibule as detailed per ANSI A 117.1-09.
7. All structural plans submitted for permit application shall be sealed by a VA Design Professional.
8. Special inspection requirements of Chapter 17 of IBC shall apply to this type of structure. (Soils, compaction, concrete, steel etc.)
9. Light poles require permits and inspections. Retaining walls with more than 3' unbalanced fill require permits.
10. No gutters of other water shall discharge over walkways.
11. A geotechnical evaluation shall be performed and submitted with application as required USBC/IBC Section 1803.
7
13
11
11
11
11
11
11
11
4
11
6 6 6 56
911
W W W W W W W W
W
6
FM
FM
FM
FM
FM
FM
FM
FM
F
M
F
M
W W W W W W W W W W W W
W
FM FM
W
W
W
W
W
E E
E
E
E
E
W
W
W
W
W
W
W
W
W
W
W
26
0
'
BUILDING #2
PROP. WAREHOUSE FACILITY
175,760 SF
APPROX. FFE = 630.70
676'
BUILDING #1
PROP. WAREHOUSE FACILITY
63,000 SF
APPROX. FFE = 631.00
18
3
'
MAIN OFFICE
SPACE (2,000 S.F.)
18
'
18
'
24
'
10'
TYP
CG-6
18
'
18
'
24
'
10'
TYP
CG-6R
CG-6
18
'
18
'
24
'
10'
TYP
CG-6CG-6 CG-6 CG-6
R=5'R=5'
R=5'
R=5'
R=5'
R=5'
R=5'
R=5'
R=5'
R=5'
R
=
5
'
R=2
5
'
R=
2
5
'
R=5'
R
=
5
'
12' CONC DOLLY PAD (SEE NOTE)
60' CONC LOADING DOCK
RETAINING WALL
VEHICLE
RAMP
LOADING DOCK DOOR
(TYP)
DUMPSTER
MID POINT ACCESS LANDING
& STAIRS
(SEE ARCHITECTURAL PLAN
FOR DETAILS)
ACCESS STAIRS
(TYP)
13.5'
TYP
60
'
T
Y
P
LIGHT FIXTURE (TYP)
EXTERIOR AREA OF REFUGE SEE
FREDERICK COUNTY INSPECTIONS
NOTE #3 SHEET 2.
11'
TYP
5' S/W
75
'
75
'
5' S/W 5' S/W
75
'
75
'
55
'
55
'
2
4
'
4'
R=2
5
'
R=25'
R=88'
R=112'
R=11
8
'
R=50'
R
=
5
0
'
R=1
0
'
60
'
C
O
N
C
L
O
A
D
I
N
G
D
O
C
K
13
.
5
'
TY
P
75' TYP
R=
2
5
'
12
'
C
O
N
C
D
O
L
L
Y
P
A
D
(
S
E
E
N
O
T
E
)
55' TYP
11
'
TY
P
R=
1
1
2
'
R=
8
8
'
R
=
5
0
'
R=5
0
'
R=5
0
'
20
'
25
'
23
.
9
'
23
.
9
'
8' A
S
P
H
A
L
T
T
R
A
I
L
8'
A
S
P
H
A
L
T
T
R
A
I
L
5 ASPHALT TRAIL
CG
-
2
T
28'
MAIN OFFICE
SPACE (2,000 S.F.)
PROP BOLLARD (TYP)PROP BOLLARD (TYP)
PROP BOLLARD
(TYP)
48
'
T
Y
P
GRASS AC
C
E
S
S
W
A
Y
TO SWM
/
B
M
P
FACILITI
E
S
CG
-
6
F
CG
-
6
F
CG
-
6
F
CG
-
6
F
CG
-
6
F
CG
-
2
T
END PHASE I /
FUTURE STREET
EXTENSION TYPE-III
TRAFFIC BARRIER W/
TYPE 4 OBJECT MARKS
55
'
T
R
A
I
L
E
R
P
A
R
K
I
N
G
CG
-
6
T
CURB
TRANSITION
CG-6R TO CG-6
LOADING DOCK
DOOR (TYP)
LIGHT FIXTURE
(TYP)
ACCESS STAIRS
(TYP)
END PHASE I /
FUTURE STREET
EXTENSION TYPE-III
TRAFFIC BARRIER W/
TYPE 4 OBJECT MARKS
5.5' x 5.5' CONC
PAD (TYP)
CG-6T CG-6T
42.
5
2
'
CG-6R
CG-6
CG-6
C
G
-
6
T
CG-6
R=
5
1
2
'
R=
4
8
8
'
8' SHOULDER
4' GRAVEL/
4' GRASS
(TYP)
4' GRASS
SHOULDER
(TYP)
LIMITS OF
DISTURBANCE
(TYP)
PROP.
TREELINE
(TYP)
LIGHT FIXTURE
(TYP)
4' GRAVEL
SHOULDER
(TYP)
CG-6TF
CG-6T
CG-12BCG-12B
CONC SCUPPER SEE
DETAIL SHEET 47
CONC SCUPPER SEE
DETAIL SHEET 47
CG-6TFR=10'R=10'
ON
Y
X
D
R
I
V
E
(PR
I
V
A
T
E
A
C
C
E
S
S
)
5.5'X5.5' CONCRETE
PAD (TYP)
10'
TYP
18
'
10'
TYP
18
'
CONC SCUPPER SEE
DETAIL SHEET 47
60' TYP
14
.
3
1
'
25'125'75'75'95.49'75'54.51'126'25'
25'155.48'94.5'90.33'98.67'94.5'117.52'
CG-6R
CG-6R CG-6R CG-6R
W
PROP
BOLLARD
(TYP)
DUMPSTER
5' CROSSWALK
21'
2
2
.
4
'
PROPOSED PICNIC AREA
21.0' x 22.4' -
4" CL A3 CONCRETE PAD
W/WELDED WIRE FABRIC
(SEE NOTE 6)
WETLAND S
H
E
L
F
ZONE 1
(ELEV
=
6
0
1
.
0
)
WETLAND S
H
E
L
F
ZONE 2
(ELEV
=
6
0
1
.
5
)
WETLAND S
H
E
L
F
ZONE 2
(ELEV
=
6
0
1
.
5
)
WETLAND S
H
E
L
F
ZONE 1
(ELEV
=
6
0
1
.
0
)
WETLAND S
H
E
L
F
ZONE 2
(ELEV
=
6
0
1
.
5
)
WETLAND S
H
E
L
F
ZONE 2
(ELEV
=
6
0
1
.
5
)
GR
I
D
M
E
R
I
D
I
A
N
VA
N
O
R
T
H
Z
O
N
E
N
A
D
8
3
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
GE
O
M
E
T
R
Y
P
L
A
N
Rev. No. Date
03 09/04/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
1" = 40'
19
06/28/2019
TTC
19-09
59
2760GC
MATCH LINE SHEET 18
MAT
C
H
L
I
N
E
S
H
E
E
T
20
NOTES:
1. TRACTOR TRAILER DOLLY PADS ARE SHOWN AT 7' BACK FROM THE FRONT OF THE SPACE AND WITH A 12' CONCRETE
WIDTH. CONTRACTOR SHALL CONFIRM LOCATION WITH THE OWNER/DEVELOPER PRIOR TO CONSTRUCTION TO
ENSURE LOCATION IS ACCEPTABLE.
2. PROPOSED BUILDING MOUNTED SIGNS SHALL BE REVIEWED AND APPROVED WITH THE FREDERICK COUNTY BUILDING
PERMIT. ANY BUSINESS SIGNS (FREESTANDING OR MONUMENT) SHALL BE REVIEWED AND APPROVED BY FREDERICK
COUNTY PLANNING DEPARTMENT PRIOR TO INSTALLATION.
3. POWER, COMMUNICATIONS AND GAS UTILITIES ARE SHOWN HERE FOR REFERENCE PURPOSES IN COORDINATION OF
CONSTRUCTION. DESIGN OF THESE SYSTEMS ARE BY THE RESPECTIVE UTILITY COMPANY PROVIDING THE SERVICE.
IF ANY CONFLICTS BETWEEN THE CIVIL PLANS AND THE UTILITY COMPANY PLANS, THE ENGINEER MUST BE NOTIFIED
IMMEDIATELY TO DETERMINE THE BEST COURSE OF ACTION.
4. CROSS WALKS SHALL BE TYPE A CLASS I WHITE PAVEMENT MARKING. LONGITUDINAL LINES SHOULD BE 12 TO 24
INCHES WIDE AND SEPARATED BY GAPS OF 12 TO 60 INCHES. THE DESIGN OF THE LINES SHOULD AVOID THE WHEEL
PATHS IF POSSIBLE, AND THE GAP BETWEEN THE LINES SHOULD NOT EXCEED 2.5 TIMES THE WIDTH OF THE
LONGITUDINAL LINES.
5. CROSSWALK SYMBOLS SHOWN ON THE PLAN ARE TO SHOW THE LOCATION OF THE PROPOSED CROSSWALKS.
CROSSWALK MARKINGS ARE TO BE LONGITUDINAL WITH THE FLOW OF TRAFFIC AND SHOULD MATCH THE EXISTING
CROSSWALK MARKINGS IN THE INDUSTRIAL CENTER IF APPLICABLE.
6. OWNER TO INSTALL 4 PICNIC TABLES PER A BUILDING WITHIN 30 DAYS OF OCCUPANCY FOR EMPLOYEE USE.
6
5
9
11
W
W
W
W
W
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
W
W
W
F
M
F
M
E
E
E
E
E
E
E
EW
W
W
W
W
W
W
W
W
W
W
W
W
SWM RETENTION POND
(SEE SHEET ##)
BU
I
L
D
I
N
G
#
1
PR
O
P
.
W
A
R
E
H
O
U
S
E
F
A
C
I
L
I
T
Y
183'
M
A
I
N
O
F
F
I
C
E
SP
A
C
E
(
2
,
0
0
0
S
.
F
.
)
12
'
C
O
N
C
D
O
L
L
Y
P
A
D
(
S
E
E
N
O
T
E
)
60
'
C
O
N
C
L
O
A
D
I
N
G
D
O
C
K
RE
T
A
I
N
I
N
G
W
A
L
L
VE
H
I
C
L
E
RA
M
P
LO
A
D
I
N
G
D
O
C
K
D
O
O
R
(T
Y
P
)
D
U
M
P
S
T
E
R
AC
C
E
S
S
S
T
A
I
R
S
(T
Y
P
)
LI
G
H
T
F
I
X
T
U
R
E
(
T
Y
P
)
11'
TY
P
24'
4'
R=25'
R
=
2
5
'
R=
8
8
'
R=
1
1
2
'
R
=
1
1
8
'
R=
5
0
'
R=5
0
'
R=10'
60' CO
N
C
L
O
A
D
I
N
G
D
O
C
K
13.5'
TYP
75'
T
Y
P
R
=
5
0
'
R=25'12' CO
N
C
D
O
L
L
Y
P
A
D
(
S
E
E
N
O
T
E
)
55'
T
Y
P
11'
TYP
R=50
'
R=
5
0
'
R=50'
R
=
5
0
'
20'
25'
23.9'
40'
8' ASPHALT TRAIL
8' ASPHALT TRAIL
8' A
S
P
H
A
L
T
T
R
A
I
L
5
A
S
P
H
A
L
T
T
R
A
I
L
PR
O
P
B
O
L
L
A
R
D
(
T
Y
P
)
PR
O
P
B
O
L
L
A
R
D
(T
Y
P
)
48' T
Y
P
CG
-
6
T
F
FOREBAY
DEEP POOL
GRASS ACCESS WAY
TO SWM/BMP
FACILITIES
GRASS ACCESS WAY
TO SWM/BMP
FACILITIES
CG-2T
EN
D
P
H
A
S
E
I
/
FU
T
U
R
E
S
T
R
E
E
T
EX
T
E
N
S
I
O
N
T
Y
P
E
-
I
I
I
TR
A
F
F
I
C
B
A
R
R
I
E
R
W
/
TY
P
E
4
O
B
J
E
C
T
M
A
R
K
S
55' TR
A
I
L
E
R
P
A
R
K
I
N
G
CG-6T
CU
R
B
TR
A
N
S
I
T
I
O
N
C
G
-
6
R
T
O
C
G
-
6
LO
A
D
I
N
G
D
O
C
K
D
O
O
R
(
T
Y
P
)
LI
G
H
T
F
I
X
T
U
R
E
(T
Y
P
)
AC
C
E
S
S
S
T
A
I
R
S
(T
Y
P
)
5.
5
'
x
5
.
5
'
C
O
N
C
PA
D
(
T
Y
P
)
C
G
-
6
T
42.52'
CG
-
6
CG
-
6
8'
S
H
O
U
L
D
E
R
4'
G
R
A
V
E
L
/
4'
G
R
A
S
S
(T
Y
P
)
LI
G
H
T
F
I
X
T
U
R
E
(T
Y
P
)
C
G
-
6
T
F
C
G
-
6
T
R=
1
0
'
ONYX DRIVE
(PRIVATE ACCESS )
POND 10YR. WSE
8'
S
H
O
U
L
D
E
R
4'
G
R
A
V
E
L
/
4'
G
R
A
S
S
(T
Y
P
)
60'
T
Y
P
14.31
'
25'
25'
15
5
.
4
8
'
94
.
5
'
W
A
R
V
PR
O
P
BO
L
L
A
R
D
(T
Y
P
)
D
U
M
P
S
T
E
R
5'
C
R
O
S
S
W
A
L
K
21'
2
2
.
4
'
21'
2
2
.
4
'
PR
O
P
O
S
E
D
P
I
C
N
I
C
A
R
E
A
21
.
0
'
x
2
2
.
4
'
-
4"
C
L
A
3
C
O
N
C
R
E
T
E
P
A
D
W
/
W
E
L
D
E
D
W
I
R
E
F
A
B
R
I
C
(S
E
E
N
O
T
E
6
)
WETLAND SHELF
ZONE 1
(ELEV=601.0)
WETLAND SHELF
ZONE 2
(ELEV=601.5)
WETLAND SHELF
ZONE 2
(ELEV=601.5)
WETLAND SHELF
ZONE 1
(ELEV=601.0)
WETLAND SHELF
ZONE 2
(ELEV=601.5)
WETLAND SHELF
ZONE 2
(ELEV=601.5)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
GRID
M
E
R
I
D
I
A
N
VA NO
R
T
H
Z
O
N
E
N
A
D
8
3
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
03 09/04/2019
1" = 40'
MATCH LINE SHEE
T
19
M
A
T
C
H
L
I
N
E
S
H
E
E
T
1
8
NOTES:
1. TRACTOR TRAILER DOLLY PADS ARE SHOWN AT 7' BACK FROM THE FRONT OF THE SPACE AND WITH A 12' CONCRETE WIDTH.
CONTRACTOR SHALL CONFIRM LOCATION WITH THE OWNER/DEVELOPER PRIOR TO CONSTRUCTION TO ENSURE LOCATION IS
ACCEPTABLE.
2. PROPOSED BUILDING MOUNTED SIGNS SHALL BE REVIEWED AND APPROVED WITH THE FREDERICK COUNTY BUILDING PERMIT. ANY
BUSINESS SIGNS (FREESTANDING OR MONUMENT) SHALL BE REVIEWED AND APPROVED BY FREDERICK COUNTY PLANNING
DEPARTMENT PRIOR TO INSTALLATION.
3. POWER, COMMUNICATIONS AND GAS UTILITIES ARE SHOWN HERE FOR REFERENCE PURPOSES IN COORDINATION OF
CONSTRUCTION. DESIGN OF THESE SYSTEMS ARE BY THE RESPECTIVE UTILITY COMPANY PROVIDING THE SERVICE. IF ANY
CONFLICTS BETWEEN THE CIVIL PLANS AND THE UTILITY COMPANY PLANS, THE ENGINEER MUST BE NOTIFIED IMMEDIATELY TO
DETERMINE THE BEST COURSE OF ACTION.
4. CROSS WALKS SHALL BE TYPE A CLASS I WHITE PAVEMENT MARKING. LONGITUDINAL LINES SHOULD BE 12 TO 24 INCHES WIDE AND
SEPARATED BY GAPS OF 12 TO 60 INCHES. THE DESIGN OF THE LINES SHOULD AVOID THE WHEEL PATHS IF POSSIBLE, AND THE GAP
BETWEEN THE LINES SHOULD NOT EXCEED 2.5 TIMES THE WIDTH OF THE LONGITUDINAL LINES.
5. CROSSWALK SYMBOLS SHOWN ON THE PLAN ARE TO SHOW THE LOCATION OF THE PROPOSED CROSSWALKS. CROSSWALK
MARKINGS ARE TO BE LONGITUDINAL WITH THE FLOW OF TRAFFIC AND SHOULD MATCH THE EXISTING CROSSWALK MARKINGS IN THE
INDUSTRIAL CENTER IF APPLICABLE.
6. OWNER TO INSTALL 4 PICNIC TABLES PER A BUILDING WITHIN 30 DAYS OF OCCUPANCY FOR EMPLOYEE USE.
GE
O
M
E
T
R
Y
P
L
A
N
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
20
06/28/2019
TTC
19-09
59
2760GC
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
S
S
S
S
S
S
S
S
S
S
S
S
S
S
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
W W
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
ARV
109
111
108
D1
D2
D3
D4
D8
D7
D6
D5
107 106
123
122
103
104
112RD1
RD2
RD3
RD7
RD8
RD4
RD6
RD5
CC1 CC2 CV4
CV3
CV2
CV1
BC1
BC2
FDC
45° BEND
11 14° BEND
PROP 12" TEE, 3-12" G.V.
12
"
W
A
T
E
R
L
I
N
E
"
A
"
45° BEND
11 14° BEND
CONNECT TO WATER LINE "K"
FROM EXTENSION SNOWDEN
BRIDGE BOULEVARD PLAN
DATED 6-22-15. CONTRACTOR TO
FIELD VERIFY ASBUILT
CONDITIONS OF WATER LINE
PRIOR TO START OF
CONSTRUCTION.
PROP 12"x8" TEE
W/6" REDUCER,
1-8" G.V., 1-6" G.V.
PROP
FH ASBY
PROP 12" TEE,
3-12" G.V.
PROP 12" x 6"
TEE, 1-6" G.V.
PROP
FH ASBY
PROP 1-6" G.V.
PROP FH ASBY
669' RADIUS
656' RADIUS
269' RADIUS
12"
W
A
T
E
R
L
I
N
E
"
A
"
12"
W
A
T
E
R
L
I
N
E
"
A
"
WATER LINE "B"
W
A
T
E
R
L
I
N
E
"
C
"
PROP 20'
FREDERICK
WATER
ESM'T.
PROP 20' WIDE
FREDERICK
WATER ESM'T.
PROP 20' WIDE
FREDERICK
WATER ESM'T.
POWER POLE
TO BE
RELOATED
POWER POLE TO
BE RELOCATED
GR
I
D
M
E
R
I
D
I
A
N
VA
N
O
R
T
H
Z
O
N
E
N
A
D
8
3
ON
Y
X
D
R
I
V
E
(PRI
V
A
T
E
A
C
C
E
S
S
)
O
N
Y
X
D
R
I
V
E
(P
R
I
V
A
T
E
A
C
C
E
S
S
)
APPROX. LOC. PROP.
REROUTING OF OHE
(DESIGN AND
CONSTRUCTION BY REC)
APP
R
O
X
.
L
O
C
.
P
R
O
P
.
RER
O
U
T
I
N
G
O
F
O
H
E
(DE
S
I
G
N
A
N
D
CON
S
T
R
U
C
T
I
O
N
B
Y
R
E
C
)
PRIVATE
FORCE SEWER
LATERAL (FSL)
METER AND BACK FLOW
PREVENTION INTERNAL TO
BUILDING (SEE NOTE 2)
APPROX. LOC. PROP.
UTLITIY POLE
APPROX. LOC. PROP.
UTLITIY POLE
APP
R
O
X
.
L
O
C
.
P
R
O
P
.
UTL
I
T
I
Y
P
O
L
E
PRO
P
.
V
A
R
I
A
B
L
E
WIDT
H
S
W
M
E
S
M
'
T
.
PRO
P
.
V
A
R
I
A
B
L
E
WIDT
H
S
W
M
E
S
M
'
T
.
75' CONSERVATION
ESM'T.
PROP. 40' VDOT
STORM ESM'T.
PROP. STORM
DRAINAGE ESM'T.
RELOCATION
45° BENDS
PROP. 40'
STORM ESM'T.
EX. DRAINAGE
ESM'T. TO BE
VACATED PRIVATE
FORCE MAIN
OPEN CUT
ROAD TO
INSTALL
SANITARY
TEST PIT
REQUIRED AT
CROSSING
0+
0
0
1+
0
0
3+00
4+0
0
5+0
0
6+0
0
7+
0
0
8+0
0
0
+
0
0
1+002+00
0+
0
0
0
+
0
0
1
+
0
0
2
+
0
0
3
+
0
0
4+0
0
4+
8
8
.
4
0
0+00 1+00
2+00
3+00
4+0
0
5+0
0
6+0
0
8+0
0
BUILDING #1
PROP. WAREHOUSE
FACILITY
PROP 20' WIDE
WATER ESM'T.
PROP 8"x6" REDUCER
PROP BOLLARD
(TYP)
6" SCH 80 SLEEVE
WITHIN W/L
EASEMENT
1
+
0
0
1
+
1
6
.
6
7
SEE NOTE 4 SHEET 21
AIR
RELEASE/VACUUM
VALVE
DEMO EX CULVERT,
REPAIR ROAD SURFACE
TO EX CONDITIONS
CV5
CV6
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
06 10/21/2019
21
06/28/2019
TTC
19-09
59
2760GC
MATCH LINE SHEET 22
MAT
C
H
L
I
N
E
S
H
E
E
T
23
1"=40'
NOTES:
1. POWER, COMMUNICATIONS AND GAS UTILITIES ARE SHOWN HERE FOR REFERENCE PURPOSES IN
COORDINATION OF CONSTRUCTION. DESIGN OF THESE SYSTEMS ARE BY THE RESPECTIVE UTILITY
COMPANY PROVIDING THE SERVICE. IF ANY CONFLICTS BETWEEN THE CIVIL PLANS AND THE UTILITY
COMPANY PLANS, THE ENGINEER MUST BE NOTIFIED IMMEDIATELY TO DETERMINE THE BEST COURSE
OF ACTION.
2. 2" DOMESTIC WATER METER AND 8" FIRE PROTECTION WATER METER AND THEIR ASSOCIATED BACK
FLOW PREVENTION DEVICES ARE LOCATED WITHIN THE FIRE PUMP ROOM. THE FIRE PROTECTION
WATER METER SHALL BE HP PROTECTUS III FIRE SERVICE METER. SEE MEP PLANS FOR DETAILS. BOTH
METERS, BACK FLOW PREVENTION DEVICES, AND AMR(AUTOMATED METER READERS) DEVICES SHALL
MEET FREDERICK WATER SPECIFICATIONS. INSTALLATION SHALL BE PER FREDERICK WATER'S
INSPECTORS REQUIREMENTS.
3. EXISTING SANITARY SEWER AND EASEMENT SHOWN PER PLAN "SANITARY SEWER FOR GRAYSTONE
COMMERCE CENTER AND STEPHENSON VILLAGE" BY STOWE ENGINEERING, PLAN DATE 11/24/2017 AND
REVISED DATE 10/3/2018.
4. EX. UTY SLEEVES SHOWN PER STOWE/RACEY "SNOWDEN BRIDGE BLVD EXT" PLANS 6/22/15
CONTRACTOR TO FIELD VERIFY PRIOR TO START OF CONSTRUCTION
ELECTRIC (WEST)
9-4" SCH 80 IN 3X3 BANKS INV:V676.27
GAS (MIDDLE)
1-12" SCH-80
INV 620.67
FORCE MAIN (EAST)
1-12" STEEL
INV 616.85
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
W W W W W W W W
W
FM
FM
FM
FM
FM
FM
FM
FM
F
M
F
M
W W W W W W W W W W W W
W
FM FM
W
W
W
W
W
E E
E
E
E
E
W
W
W
W
W
W
W
W
W
W
W
GRASS AC
C
E
S
S
W
A
Y
TO SWM
/
B
M
P
FACILITI
E
S
W
WETLAND S
H
E
L
F
ZONE 1
(ELEV
=
6
0
1
.
0
)
WETLAND S
H
E
L
F
ZONE 2
(ELEV
=
6
0
1
.
5
)
WETLAND S
H
E
L
F
ZONE 2
(ELEV
=
6
0
1
.
5
)
WETLAND S
H
E
L
F
ZONE 1
(ELEV
=
6
0
1
.
0
)
WETLAND S
H
E
L
F
ZONE 2
(ELEV
=
6
0
1
.
5
)
WETLAND S
H
E
L
F
ZONE 2
(ELEV
=
6
0
1
.
5
)
100
101
102
D10D11D12D13D14D15
121 120
D22
119
D21 D20
117118
D18
116
115
D16
114
113
110
109
111
108
D1
D2
D7
D6
D5
107 106
103
104
112
D19
D17
RD1
RD2
RD15 RD14 RD13 RD12 RD11 RD10
RD18RD19 RD17RD20RD21RD22 RD16
RD9
RD6
RD5
CC6 CC7 CC8CC5CC4
CC3
45° BEND
PROP FH ASBY
W/ 1-6" GV
PROP 12" x 6" TEE,
1-6" G.V.
PROP FH ASBY
W/ 6" GV
PROP 12" x 6" TEE,
1-6" G.V.
200' RADIUS
PROP 12" TEE,
3-12" G.V.
PROP 1-6" G.V.
PROP FH ASBY
494' RADIUS
200' RADIUS
PROP 12" CROSS,
4-12" G.V.,
PROP 80' STUB
CAPPED FOR FUTURE
CONNECTION (VALVE
TO REMAIN CLOSED)
669' RADIUS
656' RADIUS
269' RADIUS
201' RADIUS
PROP 12"
TEE, 3-12"
G.V.
PROP 60' STUB
CAPPED FOR FUTURE
CONNECTION (VALVE
TO REMAIN CLOSED)
PROP 12" x 6" TEE,
1-6" G.V.
PROP FH ASBY
W/ 1-6" GV
PROP 12" x 6" TEE,
1-6" G.V.
PROP 12" x 6" TEE,
1-6" G.V.
2-PROP FH ASBY
W/ 1-6" GV
FDC
PROP 12" x 6"
TEE, 1-6" G.V.
PROP FH ASBY
PROP 12" x 6" TEE,
1-6" G.V.
PROP FH ASBY
W/ 1-6" GV
12"
W
A
T
E
R
L
I
N
E
"
A
"
12
"
W
A
T
E
R
L
I
N
E
"
A
"
12"
W
A
T
E
R
L
I
N
E
"
A
"
W
A
T
E
R
L
I
N
E
"
C
"
WATER LINE "E"
WATER LINE "D"
W
A
T
E
R
L
I
N
E
"
D
"
W
A
T
E
R
L
I
N
E
"
D
"
PROP 20'
FREDERICK
WATER
ESM'T.
PROP 20' FREDERICK
WATER ESM'T.
PROP 20' WIDE
WATER ESM'T.
PROP 20' WIDE
FREDERICK WATER
ESM'T.
POWER POLE
TO BE
RELOATED
POWER POLE TO
BE RELOCATED
GR
I
D
M
E
R
I
D
I
A
N
VA
N
O
R
T
H
Z
O
N
E
N
A
D
8
3
PROP 20' WIDE
FREDERICK
WATER ESM'T.
O
N
Y
X
D
R
I
V
E
(P
R
I
V
A
T
E
A
C
C
E
S
S
)
PROP 20'
FREDERICK
WATER ESM'T.
APP
R
O
X
.
L
O
C
.
P
R
O
P
.
RER
O
U
T
I
N
G
O
F
O
H
E
(DE
S
I
G
N
A
N
D
CON
S
T
R
U
C
T
I
O
N
B
Y
R
E
C
)
PRIVATE
METER AND BACK FLOW
PREVENTION INTERNAL TO
BUILDING (SEE NOTE 2)
E-ONE PUMP
STATION (SEE
DETAIL SHEET 37)
PROP 12"x8" TEE
W/6" REDUCER,
1-8" G.V., 1-6" G.V.
TYPICAL TERMINAL
FLUSHING CONNECTION
(SEE DETAIL SHEET 48)
TYPICAL FLUSHING
CONNECTION
(SEE DETAIL SHEET 48)
PRE-BLAST 25' FOR
FUTURE WATERLINE
CONNECTION
6+0
0
7+
0
0
8+0
0
9+0
0
10+
0
0
11
+
0
0
12
+
0
0
1
3
+
0
0
1
3
+
8
3
.
3
9
0+
0
0
1+002+003+004+005+006+00
7
+
0
0
8
+
0
0
9
+
0
0
10
+
0
0
11
+
0
8
.
2
8
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00
9+84.80
0+00
1+00
2+00.56
6+0
0
8+0
0
9+0
0
10+
0
0
11
+
0
0
1
2
+
0
0
1
3
+
0
0
1
3
+
6
1
.
9
5
BUILDING #1
PROP. WAREHOUSE
FACILITY
BUILDING #2
PROP. WAREHOUSE
FACILITY
PROP 12" x 8" TEE, ,
1-8" G.V.
PROP 20' WIDE
WATER ESM'T.
PROP 8"x6" REDUCER
PROP BOLLARD
(TYP)PROP BOLLARD
(TYP)
PROP BOLLARD
(TYP)
PRIVATE
FORCE SEWER
LATERAL (FSL)
PRIVATE
FORCE SEWER
LATERAL (FSL)
6" SCH 80 SLEEVE
WITHIN W/L
EASEMENT
0
+
0
0
1
+
0
0
1
+
1
6
.
6
7
6" SCH 80 SLEEVE
WITHIN W/L
EASEMENT
SEE NOTE V27
ON SHEET 2
FOR ADDITIONAL
REQUIREMENTS.
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
06 10/21/2019
22
06/28/2019
TTC
19-09
59
2760GC
MATCH LINE SHEET 21
MAT
C
H
L
I
N
E
S
H
E
E
T
23
1"=40'
NOTES:
1. POWER, COMMUNICATIONS AND GAS UTILITIES ARE SHOWN HERE FOR REFERENCE PURPOSES IN
COORDINATION OF CONSTRUCTION. DESIGN OF THESE SYSTEMS ARE BY THE RESPECTIVE UTILITY
COMPANY PROVIDING THE SERVICE. IF ANY CONFLICTS BETWEEN THE CIVIL PLANS AND THE UTILITY
COMPANY PLANS, THE ENGINEER MUST BE NOTIFIED IMMEDIATELY TO DETERMINE THE BEST COURSE
OF ACTION.
2. 2" DOMESTIC WATER METER AND 8" FIRE PROTECTION WATER METER AND THEIR ASSOCIATED BACK
FLOW PREVENTION DEVICES ARE LOCATED WITHIN THE FIRE PUMP ROOM. THE FIRE PROTECTION
WATER METER SHALL BE HP PROTECTUS III FIRE SERVICE METER. SEE MEP PLANS FOR DETAILS. BOTH
METERS, BACK FLOW PREVENTION DEVICES, AND AMR(AUTOMATED METER READERS) DEVICES SHALL
MEET FREDERICK WATER SPECIFICATIONS. INSTALLATION SHALL BE PER FREDERICK WATER'S
INSPECTORS REQUIREMENTS.
3. EXISTING SANITARY SEWER AND EASEMENT SHOWN PER PLAN "SANITARY SEWER FOR GRAYSTONE
COMMERCE CENTER AND STEPHENSON VILLAGE" BY STOWE ENGINEERING, PLAN DATE 11/24/2017 AND
REVISED DATE 10/3/2018.
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
W
W
W
W
W
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
W
W
W
F
M
F
M
E
E
E
E
E
E
E
EW
W
W
W
W
W
W
W
W
W
W
W
W
SWM RETENTION POND
(SEE SHEET ##)
FOREBAY
DEEP POOL
GRASS ACCESS WAY
TO SWM/BMP
FACILITIES
GRASS ACCESS WAY
TO SWM/BMP
FACILITIES
VARIABLE
WIDTH STORM
EASEMENT
POND 10YR. WSE
W
A
R
V
WETLAND SHELF
ZONE 1
(ELEV=601.0)
WETLAND SHELF
ZONE 2
(ELEV=601.5)
WETLAND SHELF
ZONE 2
(ELEV=601.5)
WETLAND SHELF
ZONE 1
(ELEV=601.0)
WETLAND SHELF
ZONE 2
(ELEV=601.5)
WETLAND SHELF
ZONE 2
(ELEV=601.5)
100
10
110
2
D1
0
D1
1
D1
6
11
4
11
3
D8
D7
D6
D5 10
6
10
3
10
4
11
2
RD
1
1
RD
1
0
RD
1
6
RD
9
RD
6
RD
5
3
2
1
P
R
O
P
F
H
A
S
B
Y
W
/
6
"
G
V
P
R
O
P
1
2
"
x
6
"
T
E
E
,
1-
6
"
G
.
V
.
2
0
0
'
R
A
D
I
U
S
P
R
O
P
1
2
"
T
E
E
,
3-
1
2
"
G
.
V
.
P
R
O
P
1
-
6
"
G
.
V
.
P
R
O
P
F
H
A
S
B
Y
P
R
O
P
1
2
"
C
R
O
S
S
,
4-
1
2
"
G
.
V
.
,
P
R
O
P
8
0
'
S
T
U
B
C
A
P
P
E
D
F
O
R
F
U
T
U
R
E
C
O
N
N
E
C
T
I
O
N
(
V
A
L
V
E
T
O
R
E
M
A
I
N
C
L
O
S
E
D
)
6
6
9
'
R
A
D
I
U
S
6
5
6
'
R
A
D
I
U
S
2
6
9
'
R
A
D
I
U
S
2
0
1
'
R
A
D
I
U
S
P
R
O
P
1
2
"
x
6
"
T
E
E
,
1-
6
"
G
.
V
.
P
R
O
P
1
2
"
x
6
"
T
E
E
,
1
-
6
"
G
.
V
.
P
R
O
P
F
H
A
S
B
Y
12" WATER LINE "A"
12" WATER LINE "A"
12" W
A
T
E
R
L
I
N
E
"
A
"
12" WATER
L
I
N
E
"
A
"
W
A
T
E
R
L
I
N
E
"
C
"
W
A
T
E
R
L
I
N
E
"
D
"
P
R
O
P
2
0
'
F
R
E
D
E
R
I
C
K
W
A
T
E
R
E
S
M
'
T
.
P
R
O
P
2
0
'
F
R
E
D
E
R
I
C
K
W
A
T
E
R
E
S
M
'
T
.
P
O
W
E
R
P
O
L
E
T
O
B
E
R
E
L
O
A
T
E
D
P
O
W
E
R
P
O
L
E
T
O
B
E
R
E
L
O
C
A
T
E
D
ONYX DR
I
V
E
(PRIVATE
A
C
C
E
S
S
)
GRID
M
E
R
I
D
I
A
N
VA NO
R
T
H
Z
O
N
E
N
A
D
8
3
P
R
O
P
2
0
'
F
R
E
D
E
R
I
C
K
W
A
T
E
R
E
S
M
'
T
.
APPROX. LOC. PROP.
REROUTING OF OHE
(DESIGN AND
CONSTRUCTION BY REC)
P
R
I
V
A
T
E
F
O
R
C
E
S
E
W
E
R
L
A
T
E
R
A
L
(
F
S
L
)
APPROX. LOC. PROP.
UTLITIY POLE
PROP. VARIABLE
WIDTH SWM ESM'T.
PROP. VARIABLE
WIDTH SWM ESM'T.
75' CONSERVATION
ESM'T.
M
E
T
E
R
A
N
D
B
A
C
K
F
L
O
W
P
R
E
V
E
N
T
I
O
N
I
N
T
E
R
N
A
L
T
O
B
U
I
L
D
I
N
G
(
S
E
E
N
O
T
E
2
)
E-
O
N
E
P
U
M
P
S
T
A
T
I
O
N
(
S
E
E
D
E
T
A
I
L
S
H
E
E
T
3
7
)
TY
P
I
C
A
L
T
E
R
M
I
N
A
L
FLUS
H
I
N
G
C
O
N
N
E
C
T
I
O
N
(S
E
E
D
E
T
A
I
L
S
H
E
E
T
4
8
)
T
Y
P
I
C
A
L
F
L
U
S
H
I
N
G
C
O
N
N
E
C
T
I
O
N
(S
E
E
D
E
T
A
I
L
S
H
E
E
T
4
8
)
4+00
5+00
6+00
7+00
8+00
9+00
10+00
11+00
12+0
0
1
3
+
0
0
1
3
+
8
3
.
3
9
0
+
0
0
1
+
0
0
2
+
0
0
3
+
0
0
8
+
0
0
9+8
4
.
8
0
0+
0
0
1
+
0
0
2
+
0
0
.
5
6
4+00
5+00
6+00
8+00
9+00
10+00
11+00
1
2
+
0
0
1
3
+
0
0
1
3
+
6
1
.
9
5
B
U
I
L
D
I
N
G
#
1
P
R
O
P
.
W
A
R
E
H
O
U
S
E
P
R
O
P
1
2
"
x
8
"
T
E
E
,
,
1-
8
"
G
.
V
.
P
R
O
P
2
0
'
W
I
D
E
W
A
T
E
R
E
S
M
'
T
.
P
R
O
P
8
"
x
6
"
R
E
D
U
C
E
R
P
R
O
P
B
O
L
L
A
R
D
(T
Y
P
)
P
R
O
P
B
O
L
L
A
R
D
(T
Y
P
)
P
R
I
V
A
T
E
F
O
R
C
E
S
E
W
E
R
L
A
T
E
R
A
L
(
F
S
L
)
P
R
I
V
A
T
E
F
O
R
C
E
S
E
W
E
R
L
A
T
E
R
A
L
(
F
S
L
)
6"
S
C
H
8
0
S
L
E
E
V
E
W
I
T
H
I
N
W
/
L
E
A
S
E
M
E
N
T
0
+
0
0
1
+
0
0
1
+
1
6
.
6
7
AI
R
R
E
L
E
A
S
E
/
V
A
C
U
U
M
V
A
L
V
E
6"
S
C
H
8
0
S
L
E
E
V
E
W
I
T
H
I
N
W
/
L
E
A
S
E
M
E
N
T
D
E
M
O
E
X
C
U
L
V
E
R
T
,
R
E
P
A
I
R
R
O
A
D
S
U
R
F
A
C
E
T
O
E
X
C
O
N
D
I
T
I
O
N
S
S
E
E
N
O
T
E
V
2
7
O
N
S
H
E
E
T
2
F
O
R
A
D
D
I
T
I
O
N
A
L
R
E
Q
U
I
R
E
M
E
N
T
S
.
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
06 10/21/2019
1"=40'
23
06/28/2019
TTC
19-09
59
2760GC
MATCH LINE SHEE
T
22
M
A
T
C
H
L
I
N
E
S
H
E
E
T
2
1
NOTES:
1. POWER, COMMUNICATIONS AND GAS UTILITIES ARE SHOWN HERE FOR REFERENCE PURPOSES IN
COORDINATION OF CONSTRUCTION. DESIGN OF THESE SYSTEMS ARE BY THE RESPECTIVE UTILITY
COMPANY PROVIDING THE SERVICE. IF ANY CONFLICTS BETWEEN THE CIVIL PLANS AND THE UTILITY
COMPANY PLANS, THE ENGINEER MUST BE NOTIFIED IMMEDIATELY TO DETERMINE THE BEST COURSE
OF ACTION.
2. 2" DOMESTIC WATER METER AND 8" FIRE PROTECTION WATER METER AND THEIR ASSOCIATED BACK
FLOW PREVENTION DEVICES ARE LOCATED WITHIN THE FIRE PUMP ROOM. THE FIRE PROTECTION
WATER METER SHALL BE HP PROTECTUS III FIRE SERVICE METER. SEE MEP PLANS FOR DETAILS. BOTH
METERS, BACK FLOW PREVENTION DEVICES, AND AMR(AUTOMATED METER READERS) DEVICES SHALL
MEET FREDERICK WATER SPECIFICATIONS. INSTALLATION SHALL BE PER FREDERICK WATER'S
INSPECTORS REQUIREMENTS.
3. EXISTING SANITARY SEWER AND EASEMENT SHOWN PER PLAN "SANITARY SEWER FOR GRAYSTONE
COMMERCE CENTER AND STEPHENSON VILLAGE" BY STOWE ENGINEERING, PLAN DATE 11/24/2017 AND
REVISED DATE 10/3/2018.
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
S
S
S
S
S
S
S
S
S
S
S
S
S
S
63
0
640
620
6
2
0
620
6
3
2
62
8
6
3
0
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
W W
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
GRASS AC
C
E
S
S
W
A
Y
TO SWM
/
B
M
P
FACILITIE
S
W
ARV
WETLAND S
H
E
L
F
ZONE 1
(ELEV
=
6
0
1
.
0
)
WETLAND S
H
E
L
F
ZONE 2
(ELEV
=
6
0
1
.
5
)
WETLAND S
H
E
L
F
ZONE 2
(ELEV
=
6
0
1
.
5
)
WETLAND S
H
E
L
F
ZONE 1
(ELEV
=
6
0
1
.
0
)
WETLAND S
H
E
L
F
ZONE 2
(ELEV
=
6
0
1
.
5
)
WETLAND S
H
E
L
F
ZONE 2
(ELEV
=
6
0
1
.
5
)
23 68EP
24 58EP 24 60EP 24 60EP 24 60EP 24 60EP 24 60EP 24 60EP
23 30EP 23 68EP 23 68EP 23 68EP 23 68EP
24 60EP
23 30EP 23 30EP 23 30EP
%
2.
0
%
2.
0
%
2.
0 %
2.
8
%
2.
8
%
2.
8
%
2.
8
23 15TOP2315TOP2315TOP2315TOP
%1.0
%1.0
%1.0 %2.0
%2.0
31 00BLDG
31 00BLDG
31 00BLDG
31 00BLDG
31 00BLDG
24 75EP
24 EP
26 40EP
27 00EP
27 00EP
26 45EP
26 40EP
26 40EP
24 93EP
24 75EP
23 30EP
24 66EP
24 90EP
24 90EP 24 25EP
%3.0
%1.0
26 07EP
%
1.
5
%
2.
0
30 13EP 30 13EP
29 10EP
29 46EP
28 74EP2874EP
29 18EP 28 96EP
29 87EP
29 97EP
29 45EP
30 43GND
30 23SW
29 03EP
29 97EP
29 86EP
31 00GND
30 80SW
31 00GND
30 80SW
27 44EP
25 81EP
29 58EP
28 12EP 27 23EP
25 95EP
26 88EP2800GND
27 16EP
29 95GND3033GND
25 65
25 20EP
27 71GND 26 87GND2720GND
30 33GND
29 54GND
29 95GND
30 09SW
27 18GND
28 20HP
30 15SW 28 31GND
27 64GND
27 42GND
30 15GND
01
50
01
50
01
50
01
50
10
00
10
00
10
00
10
00
04
00
10
48
10
48
10
48
10
48
10
48
04
00
04
00
26 35
27 54EP
25 52EP
27 10EP
22 50TOP
26 28HP2471GND2471GND2433GND2433GND2460GND2465GND2465GND
28 00GND
30 33GND3033GND2983GND
24 63GND
25 54GND
24 63GND
30 33GND
31 00GND
29 83GND
30 80GND
30 80GND
30 62GND
30 62GND
29 89GND
29 87GND
29 24GND
30 15
26 83EP
27 16EP
29 81EP
29 99EP2819GND
27 87GND
25 69GND
26 13GND
27 30GND
28 80HP
25 28GND
25 28GND
25 28GND
24 33GND
24 63GND
24 83EP
17 84TOP
28 33BP
05
00
05
00
05
00
26 12TOP
109
111
108
D1
D2
D3
D4
D8
D7
D6
D5
107 106
123
122
103
104
112
RD1
RD2
RD3
RD7
D8
RD4
RD6
RD5
CC1
CC2
CV4
CV3
CV2
CV1
BC1
BC2
30 00
30 00
42 00
40 00
OLR
30 09SW
30 09SW
30 60GND
30 09SW
29 53GND
29 53GND
30 33GND
30 09SW
29 95GND
CV5
CV6
X-SEC "1"
X-SEC "1"
X-SEC "2"
X-SEC "2"
X-SEC "3"
X-SEC "3"
X-SEC "4"
X-SEC "4"
X-SEC "6"
X-SEC "6"
X-SEC "7"
X-SEC "7"
X-SEC "20"
X-SEC "20"
X-SEC "21"
X-SEC "21"
X-SEC "22"
X-SEC "22"
X-SEC "23"X-SEC "23"
X-SEC "24"
X-SEC "24"
X-SEC "25"X-SEC "25"
X-SEC "28"
X-SEC "28"
X-SEC "26"
X-SEC "26"
X-SEC "5"
X-SEC "5"
X-SEC "27"
X-SEC "27"
610
60
8
60
6
604
604
612
608
610
606
6
0
8
6
1
2
6
1
0
612
6
1
2
609
608
.
8
640
642
638
6
3
6
6
3
6
63
8
64
0
6
3
2
6
3
4
6
3
4
6
3
4
6
3
0
6
2
8
6
2
6
63
0
62
2
62
4
62
2
6
2
6
6
2
8
6
3
0
6
2
0
6
3
6
620
624
630
628
626
628
630
626
624
61
8
616
620
622
624
624622
620
628
628
62
8
63
0
626
628
626
624
630
628 626
624 624
628
626
624
622
622
622
624
624
626
628
628
630
630628
626
62
6
62
6
6
2
4 62
4
628
626
62
6
62
8
620624
622
626
624
626
60
4
60
6
60
8
61
0
61
4
61
6
60
2
60
2
602
600
603
601
60
3
603602
601.
0
603
601
600
01
50
01
50
01
50
01
50
01
50
01
50
01
50
01
50
GR
I
D
M
E
R
I
D
I
A
N
VA
N
O
R
T
H
Z
O
N
E
N
A
D
8
3
ON
Y
X
D
R
I
V
E
(PR
I
V
A
T
E
A
C
C
E
S
S
)
BUILDING #1
PROP. WAREHOUSE
FACILITY
63,000 SF
APPROX. FFE = 631.00
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
GR
A
D
I
N
G
P
L
A
N
Rev. No. Date
04 09/17/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
1" = 40'
24
06/28/2019
TTC
19-09
59
2760GC
MATCH LINE SHEET 25
MAT
C
H
L
I
N
E
S
H
E
E
T
26
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
63
0
630
630
620
6
2
0
6
2
0
W W W W W W W W
W
FM
FM
FM
FM
FM
FM
FM
FM
F
M
F
M
W W W W W W W W W W W W
W
FM FM
W
W
W
W
W
E E
E
E
E
E
W
W
W
W
W
W
W
W
W
W
W
W
26 70EP
29 83EP
30 70BLDG
30 70BLDG
30 70BLDG
30 70BLDG 30 70BLDG 30 70BLDG 30 70BLDG 30 70BLDG 30 70BLDG
%
1.
0
30 70BLDG
30 70BLDG
30 70BLDG
30 70BLDG
30 70BLDG3070BLDG
30 70BLDG
30 70BLDG3070BLDG3070BLDG3070BLDG
26 70EP 26 70EP 26 70EP 26 70EP
26 10EP
26 10EP2610EP
27 00EP 27 00EP
%
1.
0
%
1.
0
%
1.
0
%
1.
0
%
1.
0
%
6.
0
%
9.
8
%
5.
0
29 95EP
29 95EP2670EP
23 68EP
24 58EP
%
2.
0
%
2.
0
%
2.
0
%
2.
0
%
2.
0
%
2.
0
24 60EP 24 60EP 24 60EP 24 60EP 24 60EP 24 60EP
23 30EP 23 68EP 23 68EP 23 68EP 23 68EP
24 60EP
23 30EP 23 30EP 23 30EP
%
2.
0
%
2.
0
%
2.
0 %
2.
8
%
2.
8
%
2.
8
%
2.
8
23 15TOP2315TOP
29 16EP
23 15TOP2315TOP
29 83EP 29 83EP 29 83EP2983EP2983EP2983EP
29 56EP 29 56EP 29 56EP 29 56EP
29 67EP 29 67EP 29 67EP 29 67EP2967EP2967EP2967EP
29 16EP 29 16EP 29 16EP
28 80EP
29 16EP
%
1.
5
28 23LP
28 44EP
28 44EP
%
2.
0
%1.0
%1.0 %2.0
%2.0
31 00BLDG
31 00BLDG
29 83EP 29 83EP
%
1.
5
%
1.
5
%
1.
5
%
1.
5
%
1.
5
%
2.
0
%
2.
0
%
2.
0
%
2.
0
%
2.
0
29 56EP
29 67EP
29 56EP
29 67EP2967EP
29 16EP
30 70GND
30 50SW
30 70GND
28 44EP
30 50SW
30 70GND3013GND
29 93SW 30 50SW
30 70GND
30 50SW
30 13GND
29 93SW
29 16EP
29 56EP
28 80EP2880EP2880EP2880EP2880EP
29 16EP2916EP2916EP2916EP2916EP
28 23LP
28 44EP
28 44EP
28 23LP
28 44EP
28 44EP
28 23LP
28 44EP
28 23LP
28 44EP
28 44EP
28 44EP
28 28LP
28 88EP2888EP
28 88EP2888EP
28 88EP2888EP
28 88EP2888EP2888EP
28 88EP2888EP
29 56EP
29 02EP
29 83EP
24 75EP
24 99EP
26 70EP
30 70BLDG
27 00EP 26 45EP
26 40EP
26 40EP
24 93EP
24 75EP
23 30EP
24 66EP
24 90EP
24 90EP 24 25EP
%3.0
%1.0
25 20EP
01
50
01
50
01
50
01
50
04
00
10
48
10
48
10
48
10
48
10
48
10
48
10
48
04
00
04
00
25 79
26 35
25 57EP
27 54EP
25 97EP
26 05EP
25 52EP
25 80EP
27 10EP
22 50TOP
26 28HP2471GND2471GND2433GND2433GND2460GND2465GND2465GND
28 00GND
30 33GND3033GND2983GND
24 63GND
25 54GND
24 63GND
30 70GND
30 03GND
30 03GND
29 53GND
30 31TOP
30 45GND
30 53GND
30 70GND
30 50TRL
30 46GND
23 29EP
22 88EP
22 83EP
23 40EP
23 08
25 69GND
26 13GND
27 30GND
28 80HP
25 28GND
25 28GND
25 28GND
24 33GND
28 08EP
28 48EP 24 02EP
24 17EP2520EP
24 08EP
25 16EP 23 96EP
30 26TRL 25 76TRL
25 96GND
20 33TOP
23 60GND
26 95TOP 28 10BP
29 02GND
28 39GND
28 51GND
28 10BP
29 02GND
28 39GND
28 51GND
28 10BP
29 02GND
28 39GND
28 51GND
28 10BP
29 02GND
28 39GND
28 51GND
28 10BP
29 02GND
28 39GND
28 51GND
28 10BP
28 95GND
28 39GND
28 51GND
28 51GND
28 51GND2851GND2851GND2851GND
28 39GND
28 51GND
28 14GND
26 95TOP2839GND
28 14GND
26 95TOP2839GND
28 14GND
26 95TOP2839GND
28 14GND
26 95TOP2839GND
28 14GND
26 95TOP2839GND
28 14GND
26 52GND 24 91GND
29 44EP
29 65EP
29 05EP
29 43EP
24 63GND
29 91EP
29 93EP
30 03GND
29 53GND
27 70GND
30 70GND
30 50GND
30 20GND
29 53GND
26 01EP2603EP
25 52EP
25 36EP
24 83EP
26 18EP
26 68EP
27 10EP
27 60EP
28 35EP
28 85EP
29 43EP
28 55EP
29 63CL
28 87CL
29 38EP
29 30CL
28 62EP
29 12EP
26 31GND
17 84TOP
05
00
05
00
05
00
05
00
18 85TOP
21 43BP
%2.3 %2.0 %2.0 %2.0 %2.0 %2.0 %2.0%2.0 %2.0 %2.0 %2.0
100
101
102
D10D11D12D13D14D15
121 120
D22
119
D21 D20
117118
D18
116
115
D16
114
113
110
109
111
108
D1
D2
D7
D6
D5
107 106
103
104
112
D19
D17
RD1
RD2
RD15 RD14 RD13 RD12 RD11 RD10
RD18RD19 RD17RD20RD21RD22 RD16
RD9
RD6
RD5
CC6 CC7 CC8CC5CC4CC3
29 56EP
29 83EP
42 00
40 00
40 00
34 00
26 00
OLR
OLR
OLR
29 79GND
29 37GND
29 37GND2983GND3003GND
29 53GND
X-SEC "7"
X-SEC "7"
X-SEC "8"
X-SEC "8"
X-SEC "9"X-SEC "9"
X-SEC "10"X-SEC "10"
X-SEC "11"X-SEC "11"
X-SEC "12"
X-SEC "12"
X-SEC "13"
X-SEC "13"
X-SEC "14"X-SEC "14"
X-SEC "15"
X-SEC "15"
X-SEC "16"
X-SEC "16"
X-SEC "17"X-SEC "17"
X-SEC "18"
X-SEC "18"
X-SEC "19"
X-SEC "19"
X-SEC "20"
X-SEC "20"
600
602
600
606
603
608610
612
614
612
612
604
602
640
642
638
6
3
6
6
3
6
63
8
64
0
6
2
6
63
0
62
2
62
462
2
6
2
6
6
2
8
6
3
0
6
2
0
6
3
6
63
8
638
63
6
6
3
6
6
3
4
6
3
4
6
3
0
6
2
4
6
2
4
6
2
0
62
4
6
2
8
63
2
63
0
630634 630
63
4
630 628
628
630
630
632
628
620
612
620
626
624
610
620
620
6
1
2
6
2
0
6
1
0
62
0
61
6
62
4
62
6
62
062
2
62
4
62
6
62
8
630
628
620
618
616
614
612
610
622
624
626
620
622
620
624
626
628
626
624
630
628 626
624 624
626626
610
60
8
60
6
6
0
6
60
8
610
610614
624
616
62
6
62
6
6
2
4 624
626
62
6
62
8
620624
622
626
626
626
624
624
624
626
6
2
8
622
602
600
603
601
603602
601.
0
601
600
01
50
01
50
01
50
01
50
01
50
01
50
01
50
01
50
GR
I
D
M
E
R
I
D
I
A
N
VA
N
O
R
T
H
Z
O
N
E
N
A
D
8
3
O
N
Y
X
D
R
I
V
E
(PR
I
V
A
T
E
A
C
C
E
S
S
)
BUILDING #2
PROP. WAREHOUSE
FACILITY
175,760 SF
APPROX. FFE = 630.70
BUILDING #1
PROP. WAREHOUSE
FACILITY
63,000 SF
APPROX. FFE = 631.00
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
GR
A
D
I
N
G
P
L
A
N
Rev. No. Date
02 08/16/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
1" = 40'
25
06/28/2019
TTC
19-09
59
2760GC
MATCH LINE SHEET 24
MAT
C
H
L
I
N
E
S
H
E
E
T
26
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
630
6
2
0
610
6
2
0
6
1
0
6
0
0
610
60
0
5
9
0
620
6
2
0
620
W
W
W
W
W
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
W
W
W
F
M
F
M
E
E
E
E
E
E
E
EW
W
W
W
W
W
W
W
W
W
W
W
W14.31
'
25'
25'
15
5
.
4
8
'
94
.
5
'
W
A
R
V
21'
2
2
.
4
'
21'
2
2
.
4
'
3
0
7
0
B
L
D
G
3
0
7
0
B
L
D
G
3
0
7
0
B
L
D
G
3
0
7
0
B
L
D
G
3
0
7
0
B
L
D
G
3
0
7
0
B
L
D
G
2
6
7
0
E
P
2
6
7
0
E
P
2
6
1
0
E
P
2
6
1
0
E
P
2
7
0
0
E
P
2
7
0
0
E
P
%1.0
%1.0
%6.0
%9.8
%5.0
2
9
9
5
E
P
2
9
9
5
E
P
%2.0
%2.0
%2.0
2
4
6
0
E
P
2
4
6
0
E
P
2
4
6
0
E
P
2
4
6
0
E
P
2
3
6
8
E
P
2
3
6
8
E
P
2
3
6
8
E
P
2
3
3
0
E
P
2
3
3
0
E
P
2
3
3
0
E
P
%2.0
%2.0
%2.8
%2.8
2
3
1
5
T
O
P
2
3
1
5
T
O
P
2
3
1
5
T
O
P
%1.
0
%1.
0
%1.
0
%2.
0
%2.
0
3
1
0
0
B
L
D
G
2
4
7
5
E
P
2
4
9
9
E
P
2
6
7
0
E
P
3
0
7
0
B
L
D
G
2
6
4
0
E
P
2
7
0
0
E
P
2
7
0
0
E
P
2
6
4
5
E
P
2
6
4
0
E
P
2
6
4
0
E
P
2
4
9
3
E
P
2
4
7
5
E
P
2
3
3
0
E
P
2
4
6
6
E
P
2
4
9
0
E
P
2
4
9
0
E
P
2
4
2
5
E
P
%3.
0
%1.
0
2
6
0
7
E
P
2
6
8
8
E
P
2
8
0
0
G
N
D
2
7
1
6
E
P
2
5
6
5
2
5
2
0
E
P
2
7
7
1
G
N
D
2
6
8
7
G
N
D
2
7
2
0
G
N
D
2
8
2
0
H
P
01 50
01 500150
01 50
10 00
10 00
10 00
10 00
04 00
10 48
10 48
10 481048
10 48
10 48 10 48
10 48
10 48
04 000400
2
5
7
9
2
6
3
5
2
5
5
7
E
P
2
7
5
4
E
P
2
5
9
7
E
P
2
6
0
5
E
P
2
5
5
2
E
P
2
5
8
0
E
P
2
7
1
0
E
P
2
2
5
0
T
O
P
2
6
2
8
H
P
2
4
7
1
G
N
D
2
4
7
1
G
N
D
2
4
3
3
G
N
D
2
4
3
3
G
N
D
2
4
6
0
G
N
D
2
4
6
5
G
N
D
2
8
0
0
G
N
D
3
0
3
3
G
N
D
3
0
7
0
G
N
D
3
0
0
3
G
N
D
3
0
0
3
G
N
D
2
9
5
3
G
N
D
3
0
3
1
T
O
P
3
0
4
5
G
N
D
3
0
5
3
G
N
D
3
0
7
0
G
N
D
3
0
5
0
T
R
L
3
0
4
6
G
N
D
2
3
2
9
E
P
2
2
8
8
E
P
2
2
8
3
E
P
2
3
4
0
E
P
2
3
0
8
3
0
1
5
2
6
8
3
E
P
2
7
1
6
E
P
2
9
8
1
E
P
2
9
9
9
E
P
2
8
1
9
G
N
D
2
7
8
7
G
N
D
2
5
6
9
G
N
D
2
6
1
3
G
N
D
2
7
3
0
G
N
D
2
8
8
0
H
P
2
5
2
8
G
N
D
2
5
2
8
G
N
D
2
5
2
8
G
N
D
2
4
3
3
G
N
D
2
8
0
8
E
P
2
8
4
8
E
P
2
4
0
2
E
P
2
4
1
7
E
P
2
5
2
0
E
P
2
4
0
8
E
P
2
5
1
6
E
P
2
3
9
6
E
P
3
0
2
6
T
R
L
2
5
7
6
T
R
L
2
5
9
6
G
N
D
2
0
3
3
T
O
P
2
3
6
0
G
N
D
G
N
D
0500
05 00 05 00
0500
0500
1
8
8
5
T
O
P
2
1
4
3
B
P
07 70
07 70 07 70
07 70
05 90
100
10
110
2
D1
0
D1
1
D1
6
11
4
11
3
D8
D7
D6
D5 10
6
10
3
10
4
11
2
RD
1
1
RD
1
0
RD
1
6
RD
9
RD
6
RD
5
05 90
07 00
07 00
3
2
1
3
0
0
0
3
0
0
0
2
6
0
0
O
L
R
OLR
2
9
5
3
G
N
D
0
9
S
W
2
9
7
9
G
N
D
2
9
3
7
G
N
D
2
9
3
7
G
N
D
2
9
8
3
G
N
D
3
0
0
3
G
N
D
2
9
5
3
G
N
D
92 50LP
X-
S
E
C
"
1
6
"
X-
S
E
C
"
1
6
"
X-
S
E
C
"
1
7
"
X-
S
E
C
"
1
7
"
X-
S
E
C
"
1
8
"
X-
S
E
C
"
1
8
"
X-
S
E
C
"
1
9
"
X-
S
E
C
"
1
9
"
X-
S
E
C
"
2
0
"
X-
S
E
C
"
2
0
"
X-
S
E
C
"
2
8
"
X-
S
E
C
"
2
8
"
604
606
600
602
600
606
603
608
610
612
614
612
610
60
2
60
4
60
6
60
8
59
4
592
610 608 606 604
604
612
612
606
604
602
604
603
608
610
606
60
8
61
2
61
0
612
6
1
2
609 608.8
604
606
608
610
610
6
0
4
6
0
6
6
0
8
6
1
0
6
0
2
6
0
0
5
9
8
5
9
6
5
9
4
6
0
6
6
0
8
6
1
0
600
594
610
618
620624
610
6
2
0
6
1
2
6
2
0
6
1
0
620
616
624
626
620
622624
626
628
630
628
620
618 616 614 612 610
622
624
626620
622
620624
630 628 626
628
630
6
2
8
626
628
626
6
2
4
62
8
62
6
6
2
4
62
6
6
1
0
6
0
8
6
0
6
6
0
6
6
0
8
61
6
630
630
628
626
626
626
6
2
4
6
2
4
628
62
6
626628
620
624 622
62
6
626
62
6
6
2
4
62
4
624
626
628
622
614
612
610
608
606
604
604
616
606608610614616
618620
596
598
600
602
600 598
596
602
602
602
600
603
594
594
601
603
603602
601.0
603 601
600
602
601
596
598
600601
602
602.5
5
9
6
5
9
8
6
0
0
6
0
1
6
0
2
6
0
3
6
0
4
593
595
595
5
9
5
595596
601
602.5
01 50
01 50
01 50
01 50
01 50
01 50
01 50
603
01 50
GRID
M
E
R
I
D
I
A
N
VA NO
R
T
H
Z
O
N
E
N
A
D
8
3
ONYX DRIVE
)
ONYX DRIVE
(PRIVATE ACCE
S
S
)
B
U
I
L
D
I
N
G
#
1
P
R
O
P
.
W
A
R
E
H
O
U
S
E
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
GR
A
D
I
N
G
P
L
A
N
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
1" = 40'
26
06/28/2019
TTC
19-09
59
2760GC
MATCH LINE SHEE
T
25
M
A
T
C
H
L
I
N
E
S
H
E
E
T
2
4
CONTRACTOR TO FIELD VERIFY ASBUILT
CONDITIONS OF INTERSECTION PRIOR TO
START OF CONSTRUCTION, ENGINEER
SHALL BE NOTIFIED IMMEDIATELY IF ANY
CONFLICTS ARISE
E
E
E
E
E
E
E
H
H
BUILDING #2
BUILDING #1
ONYX
D
R
I
V
E
(PRI
V
A
T
E
ACC
E
S
S
)
ON
Y
X
D
R
I
V
E
(PR
I
V
A
T
E
AC
C
E
S
S
)
Snowden Bridge
Boulevard
C
C
C
C
C
K
K
K
F
F
F
C
Rev. No. Date
04 09/17/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
1" = 60'
27
06/28/2019
TTC
19-09
59
2760GC
MAIN SITE DRIVEWAYS - ASPHALT AREA
NOT TO SCALE
TYPICAL PAVEMENT SECTION #2
6.0" SUBBASE VDOT STD. 21B
2.0" SM-19.0A INTERMEDIATE COURSE
VDOT VTM-1 METHOD)
AT OPTIMUM MOISTURE CONTENT
(COMPACTED TO 95% DENSITYCOMPACTED SUBGRADE
OF THE SUBGRADE MUST SUBMITTED FOR ACTUAL DETERMINATION OF REQUIRED
PAVEMENT DESIGN BASED ON A SUBGRADE CBR DESIGN VALVE OF 4. SOIL TEST
PAVEMENT SECTION THICKNESS PRIOR TO CONSTRUCTION.
5.0" BM-25 BASE COURSE
1.5" SM-12.5A SURFACE COURSE
WAREHOUSE LOADING DOCK / DOLLY PAD
NOT TO SCALE
TYPICAL CONCRETE PAVEMENT SECTION #3
8" SUBBASE VDOT STD. 21B
8" 4,000 PSI REINFORCED CONCRETE
VDOT VTM-1 METHOD)
AT OPTIMUM MOISTURE CONTENT
(COMPACTED TO 95% DENSITY
COMPACTED SUBGRADE
OF THE SUBGRADE MUST SUBMITTED FOR ACTUAL DETERMINATION OF REQUIRED
PAVEMENT DESIGN BASED ON A SUBGRADE CBR DESIGN VALVE OF 4. SOIL TEST
PAVEMENT SECTION THICKNESS PRIOR TO CONSTRUCTION.
EMPLOYEE PARKING LOT - MAIN DRIVE ISLE
NOT TO SCALE
TYPICAL PAVEMENT SECTION #1
6.0" SUBBASE VDOT STD. 21B
1.5" SM-12.5A SURFACE COURSE
VDOT VTM-1 METHOD)
AT OPTIMUM MOISTURE CONTENT
(COMPACTED TO 95% DENSITY
COMPACTED SUBGRADE
OF THE SUBGRADE MUST SUBMITTED FOR ACTUAL DETERMINATION OF REQUIRED
PAVEMENT DESIGN BASED ON A SUBGRADE CBR DESIGN VALVE OF 4. SOIL TEST
PAVEMENT SECTION THICKNESS PRIOR TO CONSTRUCTION.
4.5" BM-25 BASE COURSE
WITH 6x6W2.9/2.9 WWM
PAVEMENT MARKING LEGEND
LANE LINES (BROKEN) - WHITE, TYPE B, CLASS I
MARKINGS, 4" WIDE x 10' LONG, SPACED 30'
EDGE LANE LINES (SOLID) - YELLOW, TYPE B, CLASS I
MARKINGS, 4" WIDE LENGTH AS SHOWN ON PLAN.
(OPTIONAL)
CHANNELIZING LANE LINES (SOLID) - WHITE, TYPE B,
CLASS I MARKINGS, 4" WIDE, LENGTH AS SHOWN ON
PLAN
EXTENDED LANE LINES (DOTTED) - COLOR AS
SHOWN, TYPE B, CLASS I MARKINGS, 4" WIDE x 2'
LONG, SPACED 6'. (OPTIONAL)
8" WIDTH TO BE USED FOR EMPHASIS AT
ROUNDABOUT. (OPTIONAL)
STOP BAR (SOLID) - WHITE, TYPE B, CLASS I
MARKINGS, 24" WIDE
CROSSWALK LINES - WHITE, TYPE B, CLASS I
MARKINGS, 12" WIDE x 6+' LONG, SPACED 18". SOLID
WHITE TRANSVERSE LINES PLACED PARALLEL TO
ONCOMING TRAFFIC.
TYPE B, CLASS I WHITE PAVEMENT MARKING, 6"
WIDE PARALLEL LINES SPACED 6 FEET APART.
TYPE B, CLASS I PAINTED YELLOW DOUBLE LINE
PAVEMENT MARKING, 4" WIDTH, SEPARATED BY A 4"
SPACE, LENGTH AS SHOWN ON PLAN
TYPE B WHITE PAVEMENT MARKING, 24" WIDTH,
LENGTH AS SHOWN, SPACED 6' . PLACED TO POINT
TOWARDS ONCOMING TRAFFIC.
TRIANGLE YIELD STRIPE (OPTIONAL)
TYPE 3 BARRICADES - RETROREFLECTIVE RAIL
FACES WITH R11-2 "ROAD CLOSED" SIGN.
TYPE B, CLASS I WHITE PAVEMENT MARKING,
ELONGATED TURN LANE ARROW.
TYPE B, CLASS I WHITE PAVEMENT MARKING,
ELONGATED TURN LANE ARROW.
A
B
C
D
E
G
H
I
J
K
SIGNAGE AND PAVEMENT MARKING NOTES
1. ALL PROPOSED SIGNING AND PAVEMENT MARKING SHALL BE IN ACCORDANCE WITH THE MOST RECENT EDITION OF EACH OF
THE FOLLOWING AND ANY REVISION THERETO:
A. MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES.
B. THE VIRGINIA SUPPLEMENT TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES.
C. THE VIRGINIA DEPARTMENT OF TRANSPORTATION ROAD AND BRIDGE SPECIFICATIONS.
D. THE VIRGINIA DEPARTMENT OF TRANSPORTATION ROAD AND BRIDGE STANDARDS.
2. ALL SIGNS SHALL BE CONSTRUCTED FROM ENCAPSULATED LENS SHEETING.
3. PROPOSED SIGN LOCATIONS ARE APPROXIMATE AND SHALL BE MODIFIED IN THE FIELD TO AVOID CONFLICT WITH
UNDERGROUND UTILITIES OR OTHER OBSTRUCTIONS, AND TO COMPLY WITH STANDARDS REFERENCED IN NOTE #1.
4. FOR COLOR COMBINATIONS AND/OR LETTERING SIZE, REFER TO THE VIRGINIA SUPPLEMENT TO THE MUTCD.
5. ANY EXISTING PAVEMENT MARKINGS WHICH WILL CONFLICT WITH PROPOSED PAVEMENT MARKINGS SHALL BE COMPLETELY
ERADICATED.
6. LIMITS SHOWN OF PROPOSED MARKINGS ARE APPROXIMATE AND SHALL BE MODIFIED IN THE FIELD TO INSURE THAT PROPOSED
PAVEMENT MARKINGS CONTINUE UNTIL EXISTING PAVEMENT MARKINGS CAN BE MATCHED.
7. GENERAL SIGNAGE LOCATION: MEDIAN/SHOULDER SIGNS SHALL BE PLACED 12' FROM EP TO LEADING EDGE OF SIGN. CURB
SIGNS SHALL BE PLACED 2' FROM FACE OF CURB TO LEADING EDGE OF SIGN. IF SIDEWALK IS PRESENT, LOCATE EDGE OF SIGNS 2
FEET BEHIND EDGE OF SIDEWALK.
8. UNLESS OTHERWISE NOTED, EXISTING SIGNS SHALL REMAIN IN EXISTING LOCATION.
9. TYPE "F" MARKING TO BE INSTALLED AFTER TRAFFIC LIGHT INSTALLATION.
10. ALL SIGNS AND MARKINGS SHALL BE REVIEWED IN THE FIELD WITH THE VDOT INSPECTOR PRIOR TO INSTALLATION.
PA
V
E
M
E
N
T
P
L
A
N
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19PAVEMENT SCHEMATIC (NTS)
- 2 MAIN SITE DRIVEWAYS - ASPHALT AREA
- 1 EMPLOYEE PARKING - MAIN DRIVE ISLE
- 3 TYPICAL CONCRETE PAVEMENT
- 4 ASPHALT TRAIL
TYPICAL TRAIL SECTION #4
4" COMPACTED #21A AGGREGATE
2" SM-9.5A SURFACE COARSE
COMPACTED SUBGRADE
TRAIL
NOT TO SCALE
BASE COURSE
VDOT VTM-1 METHOD)
AT OPTIMUM MOISTURE CONTENT
(COMPACTED TO 95% DENSITY
TYPE III TRAFFIC BARRICADE NOTE:
Standard:
Stripes on barricade rails shall be alternating orange and white retroreflective stripes sloping
downward at an angle of 45 degrees in the direction road users are to pass. Barricade stripes shall be 6
inch wide and shall be made of sheeting meeting the requirements in the Department of Transportation's
Road and Bridge Specifications.
The minimum length for a Type III Barricade shall be 48 inch. Each barricade rail shall be 8 to 12
inch wide. Barricades used on freeways, expressways, and other high-speed roadways shall have a
minimum of 270 sq. inch of retroreflective area facing road users.
(Ref. WAPM 6F.63)
OF THE SUBGRADE MUST SUBMITTED FOR ACTUAL DETERMINATION OF REQUIRED
PAVEMENT DESIGN BASED ON A SUBGRADE CBR DESIGN VALVE OF 4. SOIL TEST
PAVEMENT SECTION THICKNESS PRIOR TO CONSTRUCTION.
F
W W W W W
W
W
W W W W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
ARV
ONY
X
D
R
I
V
E
(PR
I
V
A
T
E
AC
C
E
S
S
)
Snowden Bridge
Boulevard
PROP. FDC
PROP. PAINTED
CURB (TYP)
SIGN TYPE "D"
SIGN TYPE "D"
SIGN TYPE
"MOD D"
SIGN TYPE
"D"
SIGN TYPE "A"
SIGN TYPE "A"
SIGN TYPE "A"
SIGN TYPE
"MOD D"
SIGN TYPE "A"
SIGN TYPE "D"SIGN TYPE "C"
SIGN TYPE "C"
SIGN TYPE "C"
SIGN TYPE "C"
SIGN TYPE "C"
SIGN TYPE "C"
SIGN TYPE "A"
SIGN TYPE
"MOD D"
PROP.
HYDRANT
PROP.
HYDRANT
PROP.
HYDRANT
PROP.
HYDRANT
PROP.
HYDRANT
PROP.
HYDRANT
PROP.
HYDRANT PROP.
HYDRANT PROP.
HYDRANT
ONY
X
D
R
I
V
E
(PR
I
V
A
T
E
AC
C
E
S
S
)
PROP. FDC
PROP.
HYDRANT
EX HYDRANT
EX HYDRANT
PROP. PAINTED
CURB (TYP)
SIGN TYPE
"D"
SIGN
TYPE
"D"
SIGN TYPE
"D"
SIGN TYPE
"D"
SIGN TYPE
"D"
SIGN TYPE
"D"
SIGN TYPE
"D"
SIGN TYPE
"D"
SIGN TYPE
"D"
SIGN TYPE
"D"SIGN TYPE
"D"SIGN TYPE
"D"
SIGN TYPE
"D"
SIGN TYPE
"D"
SIGN TYPE
"D"
SIGN TYPE
"D"
SIGN TYPE
"D"
LI
F
E
S
A
F
E
T
Y
P
L
A
N
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
01 07/22/2019
1" = 60'
28
06/28/2019
TTC
19-09
59
2760GC
*THIS VIEW FOR FIRE LANE MARKINGS & SIGNAGE ONLY
W
W
F
M
FM
FM
FM FM FM
FM
FM FM FM
FM
FM
FM
W
W
W
F
M
S
S
S
W
W
W
W
W W
W
W W W W
W
W
W
A
R
V
608
610
612
614
612
610612
6
2
0
6
1
2
6
2
0
6
1
0
620
616
624
626
620
622
624
626
628
63
0
62
8
620 618 616 614 612 610622624
626
620
622
620
624
630 628 626
628 630626624
6
1
8
620
622
624
624
622
620
628
628
6
2
8
630
626
628 626
6
2
4
6
2
4
6
2
8
6
2
662
4
622
622
6
2
2
6
2
4
624
6
2
6
628
6
2
8
630
630
628
626
626
626
6
2
4
6
2
4
628
6
2
6
626628
620
624 622
6
2
6
626
6
2
6
6
2
4
62
4
624
626
628
622
614616
ONYX DRIVE
(PRIVATE ACCESS)
11+00
12+00
13+00
14+00
15+00 16+00 17+00
18+00
19+00 20+00 21+00 22+00
23+0
0
24+
0
0
25+
0
0
GRID M
E
R
I
D
I
A
N
VA NOR
T
H
Z
O
N
E
N
A
D
8
3
4' GRASS
SHOULDER
(TYP)4' GRAVEL
SHOULDER
(TYP)
TIE INTO
EX.
TRAIL
R=275'
R=275'R=675'
R=650'R=275
'
L1
L2
L3
L4
L5
L6
C1
C2 C3
C4
C5
8' ASPHALT TRAIL 8' ASPHALT TRAIL
8' ASPHALT TRAIL
8' AS
P
H
A
L
T
T
R
A
I
L
8'
A
S
P
H
A
L
T
T
R
A
I
L
END PHASE I ROAD
CONSTRUCTION
24+76.67
PROP. 60' INGRESS/
EGRESS ESM'T
9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50 22+00 22+50 23+00 23+50
-0.30%-1.92%
10
+
1
2
.
5
0
=
P
V
I
(E
L
E
V
.
6
2
9
.
5
2
'
)
-3.70
%
10
+
3
0
.
0
0
=
P
V
I
(E
L
E
V
.
6
2
9
.
1
8
'
)
-5.6
7
%
10
+
5
2
.
7
5
=
P
V
I
(E
L
E
V
.
6
2
8
.
3
4
'
)
-4.7
0
%
10
+
8
5
.
5
0
=
P
V
I
(E
L
E
V
.
6
2
6
.
4
8
'
)
-3.93
%
1.72%
11
+
6
7
.
9
4
=
P
V
I
(E
L
E
V
.
6
2
4
.
6
6
'
)
12
+
1
7
.
9
4
=
P
V
I
(E
L
E
V
.
6
2
5
.
5
2
'
)
SAG = 11+49.63
ELEV. = 624.94
-1.46%
14
+
2
0
.
0
0
=
P
V
C
15
+
7
0
.
0
0
=
P
V
I
(E
L
E
V
.
6
3
1
.
5
9
'
)
17
+
2
0
.
0
0
=
P
V
T
CREST = 15+82.20
ELEV. = 630.41
22
+
2
5
.
0
0
=
P
V
I
(E
L
E
V
.
6
2
2
.
0
0
'
)
SAG = 22+73.72
ELEV. = 622.74
62
9
.
5
6
62
9
.
2
8
62
8
.
4
4
62
7
.
0
8
62
5
.
8
0
62
5
.
0
1
62
4
.
9
4
62
5
.
0
2
62
5
.
2
6
62
5
.
6
5
62
6
.
0
8
62
6
.
5
1
62
6
.
9
4
62
7
.
3
7
62
7
.
8
0
62
8
.
2
3
62
8
.
6
6
62
9
.
0
9
62
9
.
4
8
62
9
.
8
0
63
0
.
0
5
63
0
.
2
3
63
0
.
3
5
63
0
.
4
0
63
0
.
3
9
63
0
.
3
1
63
0
.
1
6
62
9
.
9
5
62
9
.
6
7
62
9
.
3
2
62
8
.
9
6
62
8
.
5
9
62
8
.
2
3
62
7
.
8
6
62
7
.
4
9
62
7
.
1
3
62
6
.
7
6
62
6
.
3
9
62
6
.
0
3
62
5
.
6
6
62
5
.
3
0
62
4
.
9
3
62
4
.
5
6
62
4
.
2
0
62
3
.
8
5
62
3
.
5
6
62
3
.
3
1
62
3
.
1
0
62
2
.
9
4
62
2
.
8
3
62
2
.
7
6
62
2
.
7
4
62
2
.
7
7
62
2
.
8
4
62
2
.
9
6
ELEV. @
PROP
RD C/L
SNOWDEN BRIDGE
BLVD. TO CL
(PER EX FIELD CONDITIONS)
EX. GRADE @
SNOWDEN BRIDGE
BLVD CL
11
+
0
4
.
5
0
=
P
V
I
(E
L
E
V
.
6
2
5
.
5
9
'
)
(E
L
E
V
.
6
2
5
.
0
6
'
)
11
+
1
7
.
9
4
=
B
E
G
I
N
N
I
N
G
O
F
C
O
N
S
T
R
U
C
T
I
O
N
/
P
V
I
20
+
7
5
.
0
0
=
P
V
C
COMPACT FILL
TO A MINIMUM
95% DRY
DENSITY, PER
AASHTO T-99
VDOT
STD.
CD-1
PROP. GRADE
@ C/L
Horizontal Scale: 1"=50
Vertical Scale: 1"=5
595
600
605
610
615
620
625
630
635
640
645
EXISTING
GRADE @ C/L
15
"
S
T
M
.
X
I
N
G
36
"
S
T
M
.
X
I
N
G
VC = 300.00
SD = 358'
K-Val = 94.1
VC = 100.00
SD = 421'
K-Val = 39.6
VC = 300.00
SD = 1153'
K-Val = 135.7
12" WATERLINE
1.5" PRIVATE
FORCE SEWER
LATERAL 12" WATERLINE
1.5" PRIVATE
FORCE SEWER
LATERAL
CURVE RADIUS ARC LENGTH CHORD LENGTH CHORD BEARING DELTA ANGLE TANGENT
C1 275.00' 163.42' 161.03'N 22°01'58" E 34°02'54" 84.20'
C2 275.00' 76.42' 76.18'N 31°05'44" E 15°55'22" 38.46'
C3 675.00' 123.08' 122.91'N 17°54'37" E 10°26'50" 61.71'
C4 650.00' 127.68' 127.48'N 18°18'51" E 11°15'18" 64.05'
C5 275.00' 263.39' 253.44'N 03°29'48" W 54°52'36" 142.78'
C6 275.00' 76.23' 75.98'N 22°59'38" W 15°52'56" 38.36'
C7 275.00' 219.96' 214.15'N 37°58'02" W 45°49'44" 116.25'
L1 N 05°00'31" E 92.51'
L2 N 39°03'25" E 170.09'
L3 N 23°08'03" E 143.59'
L4 N 12°41'12" E 65.64'
L5 N 23°56'30" E 165.79'
L6 N 30°56'06" W 212.94'
L7 N 15°03'10" W 170.03'
L8 N 60°52'54" W 225.86'
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
RO
A
D
P
R
O
F
I
L
E
S
Rev. No. Date
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
29
06/28/2019
TTC
19-09
59
2760GC
V: 1" = 5'
H: 1" = 50'
PLAN VIEW
1" = 50'
595
600
605
610
615
620
625
630
635
640
645
MA
T
C
H
L
I
N
E
S
H
E
E
T
3
0
W
W
F
M
FM
FM
FM FM FM
FM
FM FM FM
FM
FM
FM
W
W
W
F
M
S
S
S
W
W
W
W
W W
W
W W W W
W
W
W
A
R
V
608
610
612
614
612
610612
6
2
0
6
1
2
6
2
0
6
1
0
620
616
624
626
620
622
624
626
628
63
0
62
8
620 618 616 614 612 610622624
626
620
622
620
624
630 628 626
628 630626624
6
1
8
620
622
624
624
622
620
628
628
6
2
8
630
626
628 626
6
2
4
6
2
4
6
2
8
6
2
662
4
622
622
6
2
2
6
2
4
624
6
2
6
628
6
2
8
630
630
628
626
626
626
6
2
4
6
2
4
628
6
2
6
626628
620
624 622
6
2
6
626
6
2
6
6
2
4
62
4
624
626
628
622
614616
ONYX DRIVE
(PRIVATE ACCESS)
11+00
12+00
13+00
14+00
15+00 16+00 17+00
18+00
19+00 20+00 21+00 22+00
23+0
0
24+
0
0
25+
0
0
GRID M
E
R
I
D
I
A
N
VA NOR
T
H
Z
O
N
E
N
A
D
8
3
4' GRASS
SHOULDER
(TYP)4' GRAVEL
SHOULDER
(TYP)
TIE INTO
EX.
TRAIL
VARIABLE WIDTH
STORM EASEMENT
R=275'
R=275'R=675'
R=650'R=275
'
L1
L2
L3
L4
L5
L6
C1
C2 C3
C4
C5
8' ASPHALT TRAIL 8' ASPHALT TRAIL
8' ASPHALT TRAIL
8' AS
P
H
A
L
T
T
R
A
I
L
8'
A
S
P
H
A
L
T
T
R
A
I
L
END PHASE I ROAD
CONSTRUCTION
24+76.67
PROP. 60' INGRESS/
EGRESS ESM'T
19+50 20+00 20+50 21+00 21+50 22+00 22+50 23+00 23+50 24+00 24+50 25+00 25+50 26+00 26+50 27+00 27+50 28+00
-1.46%
22
+
2
5
.
0
0
=
P
V
I
(E
L
E
V
.
6
2
2
.
0
0
'
)
23
+
7
5
.
0
0
=
P
V
C
SAG = 22+73.72
ELEV. = 622.74
62
6
.
0
3
62
5
.
6
6
62
5
.
3
0
62
4
.
9
3
62
4
.
5
6
62
4
.
2
0
62
3
.
8
5
62
3
.
5
6
62
3
.
3
1
62
3
.
1
0
62
2
.
9
4
62
2
.
8
3
62
2
.
7
6
62
2
.
7
4
62
2
.
7
7
62
2
.
8
4
62
2
.
9
6
62
3
.
1
2
62
3
.
3
1
62
3
.
4
9
62
3
.
6
8
62
3
.
8
7
62
4
.
0
5
62
4
.
2
4
62
4
.
4
3
62
4
.
6
1
62
4
.
8
0
62
4
.
9
9
62
5
.
1
7
62
5
.
3
6
62
5
.
5
5
62
5
.
7
3
62
5
.
9
2
62
6
.
1
1
62
6
.
2
9
20
+
7
5
.
0
0
=
P
V
C
EXISTING
GRADE @ C/L
24
+
7
6
.
6
7
=
E
N
D
O
F
P
H
A
S
E
I
C
O
N
S
T
R
U
C
T
I
O
N
COMPACT FILL
TO A MINIMUM
95% DRY
DENSITY, PER
AASHTO T-99 PROP. FUTURE
GRADE @ C/L
36
"
S
T
M
.
X
I
N
G
PROP. PH1
GRADE @ C/L
18"
MIN.
VC = 300.00
SD = 1153'
K-Val = 135.7
12" WATERLINE
1.5" PRIVATE
FORCE SEWER
LATERAL
CURVE RADIUS ARC LENGTH CHORD LENGTH CHORD BEARING DELTA ANGLE TANGENT
C1 275.00' 163.42' 161.03'N 22°01'58" E 34°02'54" 84.20'
C2 275.00' 76.42' 76.18'N 31°05'44" E 15°55'22" 38.46'
C3 675.00' 123.08' 122.91'N 17°54'37" E 10°26'50" 61.71'
C4 650.00' 127.68' 127.48'N 18°18'51" E 11°15'18" 64.05'
C5 275.00' 263.39' 253.44'N 03°29'48" W 54°52'36" 142.78'
C6 275.00' 76.23' 75.98'N 22°59'38" W 15°52'56" 38.36'
C7 275.00' 219.96' 214.15'N 37°58'02" W 45°49'44" 116.25'
L1 N 05°00'31" E 92.51'
L2 N 39°03'25" E 170.09'
L3 N 23°08'03" E 143.59'
L4 N 12°41'12" E 65.64'
L5 N 23°56'30" E 165.79'
L6 N 30°56'06" W 212.94'
L7 N 15°03'10" W 170.03'
L8 N 60°52'54" W 225.86'
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
RO
A
D
P
R
O
F
I
L
E
S
Rev. No. Date
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
30
06/28/2019
TTC
19-09
59
2760GC
V: 1" = 5'
H: 1" = 50'
PLAN VIEW
1" = 50'
595
600
605
610
615
620
625
630
635
640
645
595
600
605
610
615
620
625
630
635
640
645
MA
T
C
H
L
I
N
E
S
H
E
E
T
2
9
NOTES:
1. TYPICAL SECTION BASED UPON VDOT ROAD DESIGN MANUAL - GEOMETRIC DESIGN STANDARDS URBAN
LOCAL STREET SYSTEM (GS-8).
2. STOPPING SIGHT DISTANCE AND INTERSECTION SIGHT DISTANCE BASED ON VDOT ROAD DESIGN MANUAL
APPENDIX F - ACCESS MANAGEMENT DESIGN STANDARDS FOR ENTRANCES AND INTERSECTIONS.
3. FOR TYPICAL PAVEMENT SECTION SEE SHEET 27. PAVEMENT DESIGN SHOWN IS PRELIMINARY, FINAL
PAVEMENT DESIGN WILL BE BASED ON ACTUAL FIELD CBR TESTS AND EXISTING PAVEMENT CORE DATA
SUBMITTED FOR REVIEW AND APPROVED BY ENGINEER OF RECORD PRIOR TO CONSTRUCTION.
TYPICAL ROAD SECTION
ONYX DRIVE - PRIVATE ACCESS
(GS-8 URBAN ULS LOCAL STREET)
30 MPH DESIGN SPEED
(TO BE POSTED 25 MPH OR LESS)
ONYX DRIVE - DESIGN VALUES
PROJECTED
TRAFFIC
VOLUME
(VPD)
DESIGN
SPEED
(MPH)
MIN. C/L
RADIUS
(ULS)
STOPPING
SIGHT
DISTANCE
INTERSECTION
SIGHT
DISTANCE
VERT.
CURVE MIN.
SAG K
VALUE
VERT.
CURVE MIN.
CREST K
VALUE
1,351 30 273'200'335 37 19
12'4'12'
CL
-2.08%-2.08%
LIMITS OF SUBBASE
IN
G
R
E
S
S
/
E
G
R
E
S
S
E
S
M
'
T
3:1 SLOPE
4'4'4'VARIES
-5.0%-5.0%4:1 SLOPE
GRASS
SHLDR.
-5.0%-5.0%
4' 4'
GRAVEL
SHLDR.
GRASS
SHLDR.
GRAVEL
SHLDR.
1'
MIN.UD-4 (TYP.)1'
MIN.
UD-4 (TYP.)
2'
MA
X
2
:
1
SL
O
P
E
IN
G
R
E
S
S
/
E
G
R
E
S
S
E
S
M
'
T
60'
6
2
5
.
6
W
E
W
E
6
2
5
.
6
6
4
4
6
4
6
6
4
8
6
4
0
6
4
2
S
S
S
S
S
S
S
650
6
5
0
640
650
650
630
6
4
0
630
6
3
0
620
630
640
6
4
0
650
650
6
2
0
63
0
630
6
4
0
630
620
6
1
0
620
630
6
0
0
5
9
0
5
9
0
61
0
580
620
610
610
620
5
9
0
6
4
0
640
640
640
640
630
620
630
62
0
6
2
0
610
6
2
0
6
1
0
6
0
0
64
0
62
0
61
0
6
0
0
5
9
0
620
6
2
0
620
6
3
2
628
6
3
0
6
4
2
6
4
4
W
W
W
FM
FM FM
FM FM
FM
W
W
W
W
W
W
W
W
E
E
E
E
E E
E
E
S
W W W
W W
W
A
R
V
GRID M
E
R
I
D
I
A
N
VA NO
R
T
H
Z
O
N
E
N
A
D
8
3
A
WET POND
LEVEL 2 DESIGN
FUTURE PHASE
DEVELOPMENT
FUTURE PHASE
DEVELOPMENT
FUTURE PHASE
DEVELOPMENT
GRAYSTONE INDUSTRIAL CENTER
PHASE 1
GRAYSTONE INDUSTRIAL CENTER
PHASE 1
PROJECT SITE AREA FOR
VRRM COMPUTATIONS
ONYX DRIVE
S
N
O
W
D
E
N
B
R
I
D
G
E
B
L
V
D
PROJECT SITE AREA FOR
VRRM COMPUTATIONS
RUNOFF REDUCTION
COMPLIANCE FOREST/
OPEN SPACE
L1
L2
L3
L
4
L5
L
6
L7
C1
C2
C
3
C4C5
C
6
C7
SW
M
B
M
P
P
L
A
N
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
04 09/17/2019
1"= 100'
31
06/28/2019
TTC
19-09
59
2760GC
VRRM PROJECT SITE AREA LIMITS
DRAINAGE AREA LABELS
VRRM SITE AREA TREATED
BY BMP DEVICES (WET
POND)
BMP LEGEND
A, B, C, D, E
RUNOFF REDUCTION
COMPLIANCE FOREST/OPEN
SPACE FOR BMP WATER
QUALITY
IMPERVIOUS AREA
(BUILDINGS, ROADS, ETC.)
SITE BOUNDARY (PARCEL)
NOTES:
1. VRRM COMPUTATIONS WERE BASED UPON PROVIDING WATER QUALITY FOR BOTH PROPOSED
DEVELPOMENT AND FUTURE DEVELOPMENT AS SHOWN ON THIS SHEET.
2. SUMMARY OF PROPOSED DEVELOPMENT AND FUTURE DEVELOPMENT LAND COVER AREAS:
FOREST 1.83AC, TURF 28.97 AC, IMPERVIOUS 41.03 AC. SEE VRRM COMPUTATIONS THIS SHEET.
3. THE LEVEL 2 WET POND IS LOCATED OFFSITE ON ADJACENT PARCEL. THIS DISTURBED AREA WAS
ENTERED IN THE PROJECT SITE VRRM COMPUTATIONS.
4. THE RUNOFF REDUCTION COMPLIANCE FOREST/OPEN SPACE AREA SHOWN HEREON SHALL BE
MAINTAINED IN A FOREST/OPEN SPACE MANNER UNTIL SUCH TIME THAT AN AMENDED SWM PLAN
IS APPROVED BY THE VSMP AUTHORITY.
LINE BEARING DISTANCE
L1 N 36°21'35" E 86.35'
L2 S 61°58'05" E 42.07'
L3 S 62°49'28" E 171.96'
L4 S 75°35'08" E 188.07'
L5 S 27°20'00" W 19.70'
L6 N 75°35'08" W 168.76'
L7 N 62°49'28" W 171.96'
CURVE RADIUS ARC LENGTH CHORD LENGTH CHORD BEARING DELTA ANGLE TANGENT DEGREE OF CURVE
C1 1602.35' 47.34' 47.34'S 61°07'17" E 1°41'34" 23.67' 3°34'33"
C2 20079.29' 300.22' 300.22'S 62°23'46" E 0°51'24" 150.11' 0°17'07"
C3 819.83' 182.60' 182.22'S 69°12'18" E 12°45'40" 91.68' 6°59'19"
C4 2898.17' 21.15' 21.15'S 27°07'28" W 0°25'05" 10.58' 1°58'37"
C5 10086.34' 46.32' 46.32'S 27°12'07" W 0°15'47" 23.16' 0°34'05"
C6 904.83' 201.53' 201.11'N 69°12'18" W 12°45'40" 101.18' 6°19'56"
C7 20164.29' 403.40' 403.40'N 62°15'05" W 1°08'46" 201.71' 0°17'03"
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
X X X X
X
X
X
X X X
X
X X X
X
X
X
XXXXX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
W
E
6
5
5
.
5
6
2
5
.
6
W
E
W
E
6
2
5
.
6
W
E
6
4
3
.
0
6
7
2
.
3
0
1
6
9
7
.
2
0
46
7
2
.
3
0
8
6
9
4
.
3
0
1
5
6
8
3
.
9
4
3
6
6
7
1
.
8
8
1
6
6
3
6
.
3
1
3
9
6
5
9
.
3
4
3
8
6
3
9
.
5
1
56
7
2
.
6
0
670
672
658
6
6
0
6
6
2
6
6
4
666
668
6
4
4
6
4
6
6
4
8
6
5
0
6
5
2
65
4
6
5
6
6
4
0
6
4
2
6
4
2
64
4
6
4
6
6
4
8
6
5
0
6
5
2
65
4
6
5
6
658
660
6
4
2
6
4
4
6
4
6
6
4
8
6
5
0
6
5
2
6
5
4
6
5
6
6
5
8
6
6
0
6
6
2
6
6
4
6
6
6
6
6
8
6
7
0
6
7
2
6
7
6
678
6
8
0 676
67
8
6
8
0
674
S
S
620
68
0
680
680
680
690
680
6
8
0
680
700
690
690
660
650
6
5
0
640
650
650
650
630
6
4
0
630
6
3
0
620
630
640
6
4
0
6
6
0
670
6
7
0
640
650
660
680
6
7
0
660660
6
6
0
67
0
6
7
0
650
650
6
4
0
6
5
0
6
7
0
6
7
0
670
680
6
8
0
680
680
670
690
640
640
640
630
640
6
2
0
630
620
610
600
600
6
4
0
630
6
3
0
6
2
0
630
630
6
1
0
600
6
0
0
610
620
6
3
0
620
6
4
0
630
620
6
1
0
620
630
6
0
0
5
9
0
5
9
0
610
580
620
610
610
620
610
600
590
580
5
9
0
6
0
0
6
1
0
62
0
630
6
4
0
570
580
5
9
0
6
0
0
6
1
0
6
2
0
5
7
0
6
0
0
5
9
0
5
8
0
5
7
0
6
4
0
640
640
640
640
630
620
630
620
6
2
0
610
6
2
0
6
1
0
6
0
0
64
0
620
610
60
0
5
9
0
620
600
6
1
0
63
0
640
650
6
2
0
660
6
6
0
650
630
650
650
6
6
0
630
630
640
6
5
0
640
65
0
66
0
680
680
6
8
0
6
8
0
680
700
7
3
0
7
2
0
710
700
7
2
0
7
3
0
690
690
6
8
0
6
8
0
6
8
0
680
6
9
0
6
8
0
690
6
8
0
680680
69
0
700
700
7
0
0
6
9
0
700
690
7
0
0
6
7
0
620
6
3
2
628
6
3
0
64
2
6
4
4
STUDY
POINT #1
STUDY
POINT #2
EX SWM
BASIN 2
EX SWM
BASIN 1
EX SWM
BASIN 3
10
1D
7
1
1B
3
2
6
1A
9
8
14
12
13
11
5
1C 4
TC FLOW PATH
REACH 1R
BEGIN
REACH 1R
END
REACH 2R
BEGIN
REACH 2R
END
REACH 4R
BEGIN
REACH 5R
BEGIN
REACH 5R
END
REACH 1R
END
REACH 2R
BEGIN
REACH 4R
BEGIN
REACH 4R
END
REACH 5R
BEGIN
REACH 5R
END
TC FLOW PATH
TC FLOW PATH
TC FLOW PATH
TC FLOW PATH
TC FLOW
PATH
TC FLOW
PATH
TC FLOW
PATH
GRID M
E
R
I
D
I
A
N
VA NOR
T
H
Z
O
N
E
N
A
D
8
3
11.89 AC
CN = 75
8.56 AC
CN = 79
1.81 AC
CN = 76
31.46 AC
CN = 67
15.76 AC
CN = 61
87.05 AC
CN = 61
5.75 AC
CN = 70
4.57 AC
CN = 60
5.79 AC
CN = 81
35.50 AC
CN = 79
14.0 AC
CN = 80
33.74 AC
CN = 79
127.71 AC
CN = 75
44.2 AC
CN = 81
7.97 AC
CN = 82
7.64 AC
CN = 93
9.88 AC
CN = 86
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X X X
X X X X
X
X
X
X X X
X
X X X
X
X
X
XXXXX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
S
S
FM
W
W
AR
V
STUDY
POINT #1
STUDY
POINT #2
10
1D
7
1B
3
2
6
1A
9
8
14
12
13
11
5
1C 4
TC FLOW PATH
EX SWM
BASIN 2
EX SWM
BASIN 1
EX SWM
BASIN 3
TC FLOW PATHTC FLOW PATH
TC FLOW
PATH
TC FLOW
PATH
TC FLOW
PATH
TC FLOW PATH
TC FLOW
PATH
1
REACH 1R
BEGIN
REACH 1R
END
REACH 2R
BEGIN
REACH 5R
BEGIN
REACH 1R
END
REACH 2R
BEGIN
REACH 3R
END
REACH 4R
BEGIN
REACH 4R
END
REACH 5R
BEGIN
REACH 2R
END
REACH 3R
BEGIN
REACH 5R
END
FUTURE
PHASE 2
FUTURE
PHASE 3
PHASE 1
1E
1F
GRID M
E
R
I
D
I
A
N
VA NOR
T
H
Z
O
N
E
N
A
D
8
3
87.05 AC
CN = 61
4.57 AC
CN = 60
5.79 AC
CN = 81
35.50 AC
CN = 79
14.0 AC
CN = 80
33.74 AC
CN = 79
127.71 AC
CN = 75
44.2 AC
CN = 81
7.97 AC
CN = 82
7.64 AC
CN = 93
9.88 AC
CN = 86
1.81 AC
CN = 76
5.75 AC
CN = 70
1.77 AC
CN = 86 2.53 AC
CN = 85
48.18 AC
CN = 91
8.56 AC
CN = 83
2.32 AC
CN = 78
4.24 AC
CN = 63
2.47 AC
CN = 78
SW
M
P
L
A
N
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
04 09/17/2019
1" = 400'
32
06/28/2019
TTC
19-09
59
2760GC
SITE BOUNDARY
DRAINAGE AREA LABELS
DRAINAGE DIVIDES
ONSITE DRAINAGE AREAS
TREATED BY SWM DEVICE
SWM LEGEND
1-9
STORMWATER MANAGEMENT & BEST MANAGEMENT PRACTICES SUMMARY
THE WATER QUALITY REQUIREMENTS WILL BE MET BY THE PROPOSED WET POND AND
UTILIZING FOREST/OPEN SPACE AND PURCHASING OFFSITE NUTRIENT CREDITS. THE
STORM WATER REQUIREMENTS (CHANNEL AND FLOOD PROTECTION) WERE MET BY THE
PROPOSED WET POND FOR STUDY POINT 1. STUDY POINT 2 HAS REDUCED DRAINAGE
AREAS TO MEET STORM WATER REQUIREMENTS.
NOTES:
1. EXISTING SWM BASIN 1 DATA TAKEN FROM "GRAYSTONE IND. PARK - 900K
WAREHOUSE" SITE PLAN DATED 12-18-2018.
2. EXISTING SWM BASINS 2 & 3 DATA TAKEN FROM "CONSTRUCTION PLAN FOR
SNOWDEN BRIDGE BOULEVARD" DATED 06-22-2019.
OFFSITE DRAINAGE AREAS
TO SWM DEVICE
(UNCONTROLLED)
6
1
0
6
0
0
610
60
0
620
E
E
E
E
E
E
E
E
E
E
ONYX DRIVE
(PRIVATE ACCESS )
2
3
6
8
E
P
E
P%9
9
E
P
4
0
2
3
3
0
E
P
2
4
6
6
E
P
2
4
9
0
E
P
2
4
2
5
E
P
%1.
0
2
6
0
7
E
P
2
6
8
8
E
P
2
7
1
6
E
P
2
5
6
5
2
5
2
0
E
P
01 50
01 500150
01 50
10 00
10 00
10 00
10 00
04 00
10 48
10 48
10 481048
10 48
10 48 10 48
10 48
10 48
04 000400
2
5
7
9
2
6
3
5
2
5
5
7
E
P
2
7
5
4
E
P
E
P
2
5
5
2
E
P
2
5
8
0
E
P
2
7
1
0
E
P
2
2
5
0
T
O
P
2
6
2
8
H
P
2
4
7
1
G
N
D
2
4
3
3
G
N
D
2
9
5
3
G
N
D
3
0
1
5
2
6
8
3
E
P
2
7
1
6
E
P
2
9
9
9
E
P
2
8
1
9
G
N
D
2
7
8
7
G
N
D
2
5
6
9
G
N
D
2
6
1
3
G
N
D
2
7
3
0
G
N
D
2
8
8
0
H
P
2
5
2
8
G
N
D
2
5
2
8
G
N
D
2
5
2
8
G
N
D
2
4
3
3
G
N
D
2
3
6
0
G
N
D
0500
05 00 05 00
05 00
05 00
T
O
P
B
P
07 70
07 70 07 70
07 70
05 90
100
10
110
210
3
11
2
05 90
07 00
07 00
3
2
1
3
0
0
0
2
6
0
0
O
L
R
92 50LP
604
606
600
602
600
606
603
608
610
612
614
612
610
60
2
60
4
60
6
60
8
59
4
592
610 608 606 604
604
612
612
606
604
602
604
603
608
610
606
60
8
61
2
61
0
612
6
1
2
609 608.8
604
606
608
610
610
6
0
4
6
0
6
6
0
8
6
1
0
6
0
2
6
0
0
5
9
8
5
9
6
5
9
4
6
0
6
6
0
8
6
1
0
600
594
610
618
620
616
620
620
618 616 614 612 610
622
624
626620
622
620624
630 628 626
626
628
626
6
2
4
630
628
626
626
6
2
4
6
2
4
628
62
6
626628
620
624 622
62
6
626
62
4
624
626
614
612
610
608
606
604
604
616
606608610614616
618620
596
598
600
602
600 598
596
602
602
602
600
603
594
594
601
603
603602
601.0
603 601
600
602
601
596
598
600
601
602
602.5
5
9
6
5
9
8
6
0
0
6
0
1
6
0
2
6
0
3
6
0
4
593
595
595
5
9
5
595596
601
602.5
01 50
01 50
01 50
01 50
01 50
01 50
01 50
603
01 50
SWM #1 RISER
STRUCTURE
10' AQUATIC
BENCH
"A"
12' ACCESS
12' ACCESS
WETLAND SHELF
ZONE 1
(ELEV=601.5)
WETLAND
SHELF
ZONE 2
(ELEV=602.0)
FOREBAY #1
WSE=604.00 GRASS ACCESS
WAY TO SWM/BMP
FACILITIES
NORMAL POOL
WSE=602.00
(DEEP POOL)
WETLAND
SHELF
ZONE 2
(ELEV=602.0)
GRASS ACCESS
WAY TO SWM/BMP
FACILITIES
FOREBAY #2
WSE=610.00
12
'
T
O
P
O
F
B
E
R
M
=
6
1
0
.
0
0
12'
8'10' AQUATIC
BENCH8'
8'
12'
50' WIDE SPILLWAY
ARMOUR WITH
CL II RIP-RAP
25' WIDE SPILLWAY
ARMOUR WITH
CL 1 RIP-RAP
5' WIDE SPILLWAY
ARMOUR WITH
CL 1 RIP-RAP
20' WIDE SPILLWAY
ARMOUR WITH
CL A1 RIP-RAP
12' TOP OF BERM = 606.00
10' AQUATIC
BENCH
10' AQUATIC
BENCH
5
:
1
5
:
1
5
:
1
3
:
1
5
:
1
5:1
5
:
1
5
:
1
5
:
1
5
:
1
5:1
5:1
4:1
4:1
4:1
5
:
1
5:
1
5
:
1
30'
25'
3
:
1
3:1
5' AQUATIC
BENCH
20
'
"A"
"B"
"B"
"C"
"C"
50'
26'
3:1
30' WIDE SPILLWAY
ARMOUR WITH
CL 1 RIP-RAP
WETLAND
SHELF
ZONE 3
10YR WSE = 606.66
10YR WSE = 606.92
10YR WSE = 606.92
WEIR WALL #2
WEIR WALL #1
RIP-RAP CL A1
RIP-RAP CL II
EX DRIVEWAY
ENTRANCE RETOP
WITH 4" #57 STONE
TO STABILIZE
GRID
M
E
R
I
D
I
A
N
VA NO
R
T
H
Z
O
N
E
N
A
D
8
3
RIP-RAP CL IISWM RETENTION
POND
SW
M
P
O
N
D
1
D
E
T
A
I
L
S
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
1"=30'
33
06/28/2019
TTC
19-09
59
2760GC
SW
M
P
O
N
D
1
D
E
T
A
I
L
S
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
N/A
34
06/28/2019
TTC
19-09
59
2760GC
60" RCP ASTM C-361
(RUBBER GASKETS
W.T. JOINTS)
8'
9.5'
**THE 100 YEAR WATER SURFACE ELEVATION
(WSE) ASSUMES ALL OPENINGS BELOW THE
TOP OF THE RISER ARE CLOGGED AND THE
STARTING WSE IS AT THE TOP OF THE RISER.
5:
1
12' WIDE
PROP. GRADE
1 YR WS ELEV 604.38'
10 YR WS ELEV 606.66'
100 YR WS ELEV 608.91'**
STORMWATER MANAGEMENT BASIN 1
PRINCIPAL RISER SECTION
NTS
TOP OF RISER
ELEV =607.00
TOP OF BERM
ELEV.=610.00
TYP. TRASH RACK BY
PLASTIC SOLUTION OR
APPROVED EQUAL
INV.=592.17
INV.=592.50
SPILLWAY
ELEV.=607.70
2' CLAY LINER WITH 6"
TOPSOIL CAP
8" DIP DRAIN WITH
VALVE (NORMALLY
CLOSED)
TERMINATE LINER
@ 10 YR WSE
PRECAST RCP BASE AND
RISER STRUCTURE (VDOT A4
CONCRETE) - INSIDE 10' x 8'
CONCRETE FILL
FOR BUOYANCY
NORMAL POOL WS ELEV 602.00'
8" GATE VALVE
WITH STEM
HAND WHEEL (TYP)
STEM GUIDE (TYP)
CONCRETE BLOCKS
FOR VALVE SUPPORT
WEIR ELEV = 604.80
5.5' W x 2.2' H
ELEV = 591.50
WEIR ELEV = 602.00
2.3' W x 2.8' H
UPTURNED ELBOW
(90° BEND)
BOTTOM OF TRASH RACK = 601.00
10'
9.5'
STORMWATER MANAGEMENT BASIN 1
PRINCIPAL RISER FRONT VIEW
NTS
TOP OF RISER
ELEV =607.00
TYP. TRASH RACK BY
PLASTIC SOLUTION OR
APPROVED EQUAL
INV.=591.50
PRECAST RCP BASE
AND RISER STRUCTURE
(VDOT A4 CONCRETE) -
INSIDE 10' x 8'
CONCRETE FILL
FOR BUOYANCY
INV.=592.17
WEIR ELEV = 602.00
2.3' W x 2.8' H
ELEV = 582.00
ELEV = 591.50
2.3'
2.
2
'
SIDE TRASH
RACK NOT
SHOWN FOR
CLARITY
5.5'
2.
8
'
WEIR ELEV = 604.8
5.5' W x 2.2' H
STORMWATER MANAGEMENT BASIN 1
PRINCIPAL RISER PLAN VIEW
NTS
2.3' W - WEIR
TOP TRASH RACK NOT
SHOWN FOR CLARITY
60" PIPE
PRECAST RCP BASE AND
RISER STRUCTURE (VDOT A4
CONCRETE) - INSIDE 10' x 8'8" PIPE
PLASTIC SOLUTIONS TRASH
RACK OR APPROVED EQUAL
10'
8'
5.5' W - WEIR
NOTES:
1. CONSTRUCTION TO COMPLY WITH
RECOMMENDATIONS FROM GEOTECHNICAL
REPORT.
WEIR WALL #1
NOT TO SCALE
30' WEIR WIDTH
PROPOSED
GRADE
FRONT VIEW
40' LENGTH
3:1
NOTE: RIP-RAP TO BE FLUSH WITH
TOP OF CONCRETE WEIR WALL.
WEIR WALL TO BE LEVEL.
3:
1
CONCRETE WEIR
(VDOT CLASS A3)
5'
1.0'
5'
4.0'
2.0'
2.0'
RIP-RAP (VDOT CLASS 1)
NOT SHOWN FOR
CLARITY OF WEIR WALL
ELEV =606.00 ELEV =606.00
ELEV =605.00ELEV =605.00
WEIR WALL #1
NOT TO SCALE
NON-WOVEN
GEOTEXTILE
FABRIC
RIP-RAP CL. I
CONCRETE WEIR WALL
(8" VDOT CLASS A3)
SIDE VIEW
22'
2.0'
2.0'
PROPOSED
GRADE
RIP-RAP FLUSH WITH
TOP OF WEIR WALL
12"x24" FOOTING
(VDOT 21A)
2'
#4's, 24" O.C. (V.)
#4's, 12" O.C. (H.)
NOTES:
1. REINFORCING STEEL ASTM A615,
GRADE 60. MINIMUM BAR LAP 20".
2. MINIMUM SOIL BEARING 2,000 PSF TO
BE FIELD VERIFIED.
3. COMPACTED SOILS, AS NEEDED, TO
BE MIN. 95% OF ASTM D-698/VTM-1.
WEIR WALL #2
NOT TO SCALE
4' WEIR
WIDTH
PROPOSED
GRADE 3:1
FRONT VIEW
27' LENGTH
NOTE: RIP-RAP TO BE FLUSH WITH
TOP OF CONCRETE WEIR WALL.
WEIR WALL TO BE LEVEL.
2:
1
CONCRETE WEIR
(VDOT CLASS A3)
5'
6.0'
2.0'
2.0'
RIP-RAP (VDOT CLASS 1)
NOT SHOWN FOR
CLARITY OF WEIR WALL
2.0'
12'5'
2:1
PROPOSED
GRADE 3:1
ELEV =606.00
ELEV =606.00
ELEV =604.00
WEIR WALL #2
NOT TO SCALE
NON-WOVEN
GEOTEXTILE
FABRIC
RIP-RAP CL. I
CONCRETE WEIR WALL
(8" VDOT CLASS A3)
SIDE VIEW
32'
2.0'
2.0'
PROPOSED
GRADE
RIP-RAP FLUSH WITH
TOP OF WEIR WALL
2.0'
12"x24" FOOTING
(VDOT 21A)
2'
#4's, 24" O.C. (V.)
#4's, 12" O.C. (H.)
NOTES:
1. REINFORCING STEEL ASTM A615,
GRADE 60. MINIMUM BAR LAP 20".
2. MINIMUM SOIL BEARING 2,000 PSF TO
BE FIELD VERIFIED.
3. COMPACTED SOILS, AS NEEDED, TO
BE MIN. 95% OF ASTM D-698/VTM-1.
9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50
565
570
575
580
585
590
595
600
605
610
615
620
565
570
575
580
585
590
595
600
605
610
615
620
POND DRAIN
DEEP POOL
1YR WSE=604.38
BMP (1") WSE=602.49
10YR WSE=606.66
EMERGENCY
SPILLWAY =607.70
TOP OF BERM
ELEV.=610.00 12.0'
4:1
5
:
1
100YR WSE=608.91**
NORMAL POOL
WSE=602.00
(Tv=261,880 ft3)
5
:
1
106' - 60" RCP
ASTM C-361
(RUBBER
GASKETS W.T.
JOINTS) @ 0.75%
0.5%
CONTROLLED FILL -
EMBANKMENT TO BE
CONSTRUCTED WITH CLAY
CORE
PROP.
GRADEEX. GRADE
11
+
0
6
=
R
I
S
E
R
S
T
R
U
C
T
U
R
E
(
1
0
'
x
8
'
)
IN
V
O
U
T
=
5
9
1
.
5
0
(
6
0
"
)
IN
V
I
N
=
5
9
2
.
1
7
(
8
"
D
R
A
I
N
)
10
+
0
0
=
E
W
-
2
P
C
IN
V
O
U
T
=
5
9
0
.
7
0
1
TO
P
=
5
9
7
.
7
0
2
TO
P
=
6
0
7
.
0
0
3
TOP OF BERM
ELEV.=612.00
FOREBAY
OVERFLOW =610.00
5
:
1
5
:
1
5:1
5:1
11
+
7
3
=
8
"
D
R
A
I
N
W
I
T
H
U
P
T
U
R
N
E
D
E
L
B
O
W
IN
V
O
U
T
=
5
9
2
.
5
0
CUT-OFF TRENCH
4.0' MIN. DEPTH
WITH 1:1 SIDE
SLOPES OR
FLATTER
12.0'
FOREBAY #2
CONCRETE CRADLE
4.0'
PHREATIC
LINE
4:1
CONTROLLED FILL -
EMBANKMENT
6" TOPSOIL
COVER
NOTES:
1. CLAY LINER NOT SHOWN FOR CLARITY. SEE PLAN VIEW & SCHEMATIC FOR LIMITS.
2. THE 100 YEAR WATER SURFACE ELEVATION (WSE) ASSUMES ALL OPENINGS
BELOW THE TOP OF THE RISER ARE CLOGGED AND THE STARTING WSE IS THE TOP
OF THE RISER.
3. ALL STORMWATER MANAGEMENT FACILITIES TO BE CERTIFIED BY A
GEOTECHNICAL ENGINEER OR CONSTRUCTION INSPECTOR.
4. EMBANKMENT CONTROLLED FILL (SOIL MATERIALS) TO BE CERTIFIED BY A
GEOTECHNICAL ENGINEER.
5. REFER TO GENERAL NOTES - PERMANENT SWM EMBANKMENT NOTES ON SHEET 2.
6. PHREATICLINE DOES NOT CROSS THE TOE OF THE EMBANKMENT THEREFORE NO
DRAINAGE SYSTEM IS REQUIRED.
7. POND OUTFALL PIPE SHALL BE BEDDED WITH FINE GRAINED SOILS. FINE GRAINED
SOILS SHALL HAVE STONE 1" OR LESS IN DIAMETER FOR A MINIMUM OF 2' AROUND
PIPE IN AREAS OF BACKFILL.
8. CLAY CORE 4' MINIMUM WIDTH STARTING AT THE 10YR WSE AND 1:1 SIDE SLOPES.
HOMOGENEOUS FILL
COMPACTED TO 95%
DENSITY
40' - CLASS II
RIP-RAP
1%
-0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00
585
590
595
600
605
610
615
585
590
595
600
605
610
615
-0+50 0+00 0+50 1+00
585
590
595
600
605
610
615
585
590
595
600
605
610
615
CLAY LINER
TYP.
5
:
1
5
:
1
5:1
5:1
12.0'
FOREBAY #1
5:1
5:1
WETLAND
SHELF
WETLAND
SHELF
EX. GRADE
NORMAL POOL
WSE=602.00
(Tv=261,880 ft3)
FOREBAY
OVERFLOW =604.00
TOP OF BERM
ELEV.=606.00
TOP OF BERM
ELEV.=603.00
8.0'
100
DEEP POOL
5
:
1
12.0'
5:1
FOREBAY
OVERFLOW =605.00
TOP OF BERM
ELEV.=606.00
1+50
DEEP POOL
NORMAL POOL
WSE=602.00
(Tv=261,880 ft3)
EX. GRADE
5:1
5
:
1
CLAY LINER
TYP.
FOREBAY #1
PROP.
GRADE
PROP.
GRADE
CLAY LINER
TYP.
1YR WSE=604.38
BMP (1") WSE=602.49
10YR WSE=606.66
100YR WSE=608.91**
NORMAL POOL
WSE=602.00
(Tv=261,880 ft3)
1YR WSE=604.38
BMP (1") WSE=602.49
10YR WSE=606.66
100YR WSE=608.91**
SW
M
P
O
N
D
1
D
E
T
A
I
L
S
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
35
06/28/2019
TTC
19-09
59
2760GC
CLAY LINER NOTES:
1. A CLAY LINER SHOULD HAVE A MINIMUM THICKNESS OF 24 INCHES AND
SHOULD COMPLY WITH THE SPECIFICATIONS PROVIDED IN TABLE 3.07-3.
2. A LAYER OF COMPACTED TOPSOIL (MINIMUM 6-12 INCHES THICK) SHOULD BE
PLACED OVER THE LINER BEFORE SEEDING WITH AN APPROPRIATE SEED
MIXTURE (REFER TO VESCH, 1992 EDITION).
3. A SYNTHETIC LINER WITH A MINIMUM THICKNESS OF 60 MIL. OR OTHER LINER
TYPES MAY BE USED IF SUPPORTING DOCUMENTATION IS PROVIDED
VERIFYING THE LINER MATERIAL'S PERFORMANCE.
50'
EMERGENCY SPILLWAY
NOT TO SCALE
2.3'3:
1 3:1
TOP OF BERM = 610.00
63.8'
ELEV = 607.70
10' WIDE
AQUATIC
BENCH
5:1
S
I
D
E
S
L
O
P
E
5:1
S
I
D
E
S
L
O
P
E
AQUATIC BENCH DETAIL
NOT TO SCALE
10% M
A
X
FOREBAYS
& DEEP
POOLS
POND SLOPES 5:1 OR
FLATTER DO NOT
REQUIRE A SAFETY
BENCH
5' WIDE AQUATIC
BENCH ( FOR SAFETY
PURPOSES)
5:1
S
I
D
E
S
L
O
P
E
5:1
S
I
D
E
S
L
O
P
E
AQUATIC BENCH DETAIL-FOREBAY #2
NOT TO SCALE
FOREBAY #2
ONLY
12"4%
1"= 50' H
1"= 5' V
48 82 41 74 0.483
PUBLIC GRAVITY SANITARY
PROFILE
EXISTING MANHOLE TO BUILD 1
PRIVATE FORCED SEWER LATERAL PROFILE
FROM MH C TO STUB
-0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50
600
605
610
615
620
625
630
635
595
600
605
610
615
620
625
630
635
12
"
W
/
L
X
I
N
G
15
"
S
T
M
.
XI
N
G
-0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00
605
610
615
620
625
630
635
600
605
610
615
620
625
630
635
PRIVATE FORCED SEWER LATERAL PROFILE
POINT D TO PS-E TO BUILDING 2
2+
0
0
.
5
6
=
C
O
N
N
E
C
T
I
O
N
T
O
B
U
I
L
D
2
IN
V
O
U
T
=
6
2
6
.
2
1
-0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50
615
620
625
630
635
610
615
620
625
630
635
BL
D
G
F
A
C
E
FFE = 631.00'
4+
8
8
.
4
0
=
T
I
E
T
O
B
L
D
G
S
A
N
IN
V
=
6
2
3
.
8
3
4+
4
1
.
9
0
=
M
H
C
IN
V
O
U
T
=
6
2
1
.
9
0
IN
V
I
N
=
6
2
2
.
1
0
3+
6
3
.
1
5
=
M
H
B
IN
V
O
U
T
=
6
2
1
.
3
1
IN
V
I
N
=
6
2
1
.
5
1
0+
0
0
=
E
X
M
H
EX
I
N
V
O
U
T
=
6
1
9
.
3
3
EX
I
N
V
I
N
=
6
1
9
.
5
0
PR
O
P
I
N
V
I
N
=
6
1
9
.
5
3
363.15'
8" DIP @
0.50%
71.35'
8" DIP @
0.50%
12
"
W
/
L
XI
N
G
FFE=630.70'
1+
8
0
.
5
6
=
P
U
M
P
S
T
A
T
I
O
N
E
IN
V
I
N
=
6
2
5
.
6
5
PU
M
P
S
T
A
T
I
O
N
RI
M
=
6
3
0
.
3
1
1
640 640
0+
0
0
.
0
0
=
S
A
N
P
R
E
S
S
U
R
E
T
E
E
"
D
"
CO
N
N
E
C
T
I
O
N
T
O
F
M
BL
D
G
F
A
C
E
36
"
S
T
M
.
XI
N
G
12
"
W
/
L
XI
N
G
EX
1
2
"
W
/
L
X
I
N
G
1+
0
1
.
6
0
=
4
5
°
B
E
N
D
1+
5
4
.
2
1
=
4
5
°
B
E
N
D
1+
7
5
.
5
7
=
4
5
°
B
E
N
D
12
+
3
1
.
7
1
=
P
O
I
N
T
D
,
S
A
N
P
R
E
S
S
U
R
E
T
E
E
CO
N
N
E
C
T
I
O
N
T
O
B
U
I
L
D
2
,
W
I
T
H
F
L
U
S
H
I
N
G
VA
L
V
E
18"
MIN.
18"
MIN.
18"
MIN.
18"
MIN.
18"
MIN.
EX. GRADE
@ PIPE C/L
PROP.
GRADE @
PIPE C/L
46.54'
6" SDR 35/26
@ 3.69%
EX. GRADE
@ PIPE C/L
PROP.
GRADE @
PIPE C/L
PRIVATE 1.5"
PVC FORCED
SEWER
LATERAL (FSL)
20'
6" SDR 35/26
@ 2.8%
COMPACT FILL TO 95%
MAXIMUM DRY DENSITY
PER ASTM D 698
COMPACT FILL TO 95%
MAXIMUM DRY DENSITY
PER ASTM D 698
EXISTING WATERLINE
ELEVATION ESTIMATED, TEST
PIT REQUIRED PRIOR TO
CONSTRUCTION TO VERIFY
STUB TO BE CAPPED AS
REQUIRED BY FREDERICK
WATER
EX. GRADE
@ PIPE C/L PROP.
GRADE @
PIPE C/L
EX. GRADE
@ PIPE C/L
PROP.
GRADE @
PIPE C/L
PRIVATE 1.5"
PVC SANITARY
FM
PRIVATE 1.5"
PVC PRIVATE
FORCED SEWER
LATERAL (FSL)
PRIVATE 1.5" PVC
FORCED DEWER
LATERAL (FSL)
BLDG #1BLDG #2
6" SCH 80 SLEEVE
WITHIN W/L EASEMENT
600
6" SCH 80 SLEEVE
WITHIN W/L EASEMENT
12
"
W
/
L
X
I
N
G
18"
MIN.
6" SCH 80 SLEEVE
WITHIN W/L EASEMENT
0+
0
0
.
0
0
=
M
H
C
IN
V
O
U
T
=
6
2
1
.
9
4
(
8
"
)
IN
V
I
N
=
6
2
2
.
1
4
(
6
"
)
IN
V
I
N
=
6
2
2
.
1
4
(
1
.
5
"
)
24
"
S
T
M
.
XI
N
G
1.72'
CLEARANCE
PIPE TO BE ENCASED IN
6" THICK CONCRETE
WHERE COVERAGE IS
LESS THAN 18"
4' - PRIVATE
1.25" PVC
FORCED SEWER
LATERAL (FSL)
1.
2
5
"
-
1
.
5
"
RE
D
U
C
E
R
TO
P
=
6
2
7
.
2
5
TO
P
=
62
9
.
5
4
SA
N
I
T
A
R
Y
S
E
W
E
R
P
R
O
F
I
L
E
S
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
01 07/22/2019
36
06/28/2019
TTC
19-09
59
2760GC
V: 1" = 5'
H: 1" = 50'
PR
I
V
A
T
E
S
A
N
I
T
A
R
Y
P
U
M
P
S
T
A
T
I
O
N
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
01 07/22/2019
37
06/28/2019
TTC
19-09
59
2760GC
V: 1" = 5'
H: 1" = 50'
PRIVATE SEWER DETAILS AND CALCULATIONS
100
101
104 112 106
D8
D7
D6D5
102
RD9RD7
101
102
103 104 106 107 108
109
110
9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00
590
595
600
605
610
615
620
625
630
635
590
595
600
605
610
615
620
625
630
635
9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50
595
600
605
610
615
620
625
630
635
640
595
600
605
610
615
620
625
630
635
640
9+50 10+00 10+50 11+00
600
605
610
615
620
625
630
635
640
600
605
610
615
620
625
630
635
640
9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00
600
605
610
615
620
625
630
635
640
600
605
610
615
620
625
630
635
640
-0+50 0+00 0+50 1+00
600
605
610
615
620
625
630
635
640
600
605
610
615
620
625
630
635
640
STR 100 - STR 101
STR 101 - STR 110
STR 104 - STR 112 ROOF DRAIN STR 106 - D8
169' - 30" ADS N-12 @ 0
.
9
9
%
140' - 30" ADS N-12 @ 0.60%
94' - 30" ADS N-12
@ 0.60%
145' - 30" ADS N-12 @ 0.50%
135' - 24" ADS N-12 @ 0.60%
129' - 24" ADS N-12 @ 0.50%
144' - 15" ADS N-12 @ 0.55%
120' - 15
"
A
D
S
N
-
1
2
@
3
.
3
9
%
26'
-
1
5
"
ADS
N
-
1
2
@
9
.
0
5
%
30' - 12"
PVC
@ 3.19
%
23' - 1
2
"
PVC
@ 5.
1
9
%
73' - 12" PVC
@ 2.00%
36
'
-
12
"
P
V
C
@
2
4
.
8
9
%
EXISTING
GRADE
PROPOSED
GRADE
HGL
10' CL I RIP
RAP
EXISTING
GRADE
EXISTING
GRADE
PROPOSED
GRADE
PROPOSED
GRADE
HGL
HGL
HGL
EXISTING
GRADE
PROPOSED
GRADE
PROPOSED
GRADE
EXISTING
GRADE HGL
ROOF DRAIN STR 102 - D9
PROPOSED
GRADE
EXISTING
GRADE
HGL
12
"
W
A
T
E
R
L
I
N
E
12
"
W
/
L
X-
I
N
G
18"
MIN.
12
+
2
3
.
9
3
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(7
2
"
B
A
S
E
)
IN
V
O
U
T
=
6
0
7
.
5
6
(
3
6
"
)
IN
V
I
N
=
6
0
7
.
6
6
(
3
0
"
)
IN
V
I
N
=
6
0
7
.
6
6
(
3
0
"
)
10
+
0
0
=
E
S
-
1
IN
V
O
U
T
=
6
0
5
.
0
0
(
3
6
"
)
10
+
0
0
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(6
0
"
B
A
S
E
)
IN
V
O
U
T
=
6
1
0
.
9
3
(
3
0
"
)
IN
V
I
N
=
6
1
7
.
2
5
(
1
5
"
)
IN
V
I
N
=
6
1
1
.
0
3
(
3
0
"
)
10
+
2
5
.
7
0
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(4
8
"
B
A
S
E
)
IN
V
O
U
T
=
6
1
9
.
5
8
(
1
5
"
)
10
+
0
0
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(6
0
"
B
A
S
E
)
IN
V
O
U
T
=
6
1
1
.
7
5
(
3
0
"
)
IN
V
I
N
=
6
1
8
.
3
2
(
1
2
"
)
IN
V
I
N
=
6
1
2
.
2
5
(
2
4
"
)
10
+
3
0
.
2
6
=
1
2
"
W
y
e
IN
V
=
6
1
9
.
2
8
10
+
5
3
.
1
1
=
1
2
"
4
5
°
B
e
n
d
IN
V
=
6
2
0
.
4
7
11
+
2
5
.
9
5
=
1
2
"
W
y
e
IN
V
=
6
2
1
.
9
3
12
+
2
9
.
9
5
=
1
2
"
4
5
°
B
e
n
d
IN
V
=
6
2
4
.
8
3
12
+
4
2
.
6
8
=
R
O
O
F
D
R
A
I
N
IN
V
O
U
T
=
6
2
6
.
5
0
0+
0
0
.
0
0
=
M
H
-
1
(
6
0
"
B
A
S
E
)
IN
V
O
U
T
=
6
0
9
.
3
3
(
3
0
"
)
IN
V
I
N
=
6
1
7
.
9
3
(
1
2
"
)
IN
V
I
N
=
6
0
9
.
4
3
(
3
0
"
)
IN
V
I
N
=
6
1
4
.
9
3
(
1
8
"
)
0+
3
6
.
3
0
=
R
O
O
F
D
R
A
I
N
IN
V
O
U
T
=
6
2
6
.
9
7
10
+
0
0
.
0
0
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(7
2
"
B
A
S
E
)
IN
V
O
U
T
=
6
0
7
.
5
6
(
3
6
"
)
IN
V
I
N
=
6
0
7
.
6
6
(
3
0
"
)
IN
V
I
N
=
6
0
7
.
6
6
(
3
0
"
)
11
+
6
8
.
7
8
=
M
H
-
1
(
6
0
"
B
A
S
E
)
IN
V
O
U
T
=
6
0
9
.
3
3
(
3
0
"
)
IN
V
I
N
=
6
0
9
.
4
3
(
3
0
"
)
IN
V
I
N
=
6
1
7
.
9
3
(
1
2
"
)
IN
V
I
N
=
6
1
4
.
9
3
(
1
8
"
)
13
+
0
9
.
0
7
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(6
0
"
B
A
S
E
)
IN
V
O
U
T
=
6
1
0
.
2
7
(
3
0
"
)
IN
V
I
N
=
6
1
0
.
3
7
(
3
0
"
)
14
+
0
2
.
6
2
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(6
0
"
B
A
S
E
)
IN
V
O
U
T
=
6
1
0
.
9
3
(
3
0
"
)
30
"
I
N
V
I
N
=
6
1
1
.
0
3
(
3
0
"
)
IN
V
I
N
=
6
1
7
.
2
5
(
1
5
"
)
15
+
4
7
.
2
3
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(6
0
"
B
A
S
E
)
IN
V
O
U
T
=
6
1
1
.
7
5
(
3
0
"
)
IN
V
I
N
=
6
1
2
.
2
5
(
2
4
"
)
IN
V
I
N
=
6
1
8
.
3
2
(
1
2
"
)
16
+
8
1
.
9
8
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(6
0
"
B
A
S
E
)
IN
V
O
U
T
=
6
1
3
.
0
6
(
2
4
"
)
IN
V
I
N
=
6
1
3
.
1
6
(
2
4
"
)
18
+
1
0
.
6
2
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(6
0
"
B
A
S
E
)
IN
V
O
U
T
=
6
1
3
.
8
0
(
2
4
"
)
IN
V
I
N
=
6
1
4
.
0
5
(
1
5
"
)
IN
V
I
N
=
6
1
4
.
0
5
(
1
5
"
)
IN
V
I
N
=
6
2
0
.
2
4
(
1
2
"
)
19
+
5
4
.
4
8
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(4
8
"
B
A
S
E
)
IN
V
O
U
T
=
6
1
4
.
8
4
(
1
5
"
)
IN
V
I
N
=
6
1
4
.
9
4
(
1
5
"
)
20
+
7
4
.
6
6
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(4
8
"
B
A
S
E
)
IN
V
O
U
T
=
6
1
9
.
0
2
(
1
5
"
)
TO
P
=
6
1
8
.
8
5
TO
P
=
6
0
6
.
0
0
TO
P
=
6
2
3
.
1
5
TO
P
=
6
2
3
.
1
0
TO
P
=
6
2
3
.
1
5
TO
P
=
6
2
6
.
2
8
TO
P
=
6
2
2
.
0
2
TO
P
=
6
1
7
.
8
4
TO
P
=
6
2
3
.
1
4
TO
P
=
6
2
3
.
1
5
TO
P
=
6
2
3
.
1
5
TO
P
=
6
2
3
.
1
5
TO
P
=
6
2
3
.
3
0
TO
P
=
6
2
6
.
2
8
TO
P
=
6
1
8
.
8
5
3"
F
O
R
C
E
M
A
I
N
X
-
I
N
G
8"
W
/
L
X-
I
N
G
104' - 12"
P
V
C
@
2
.
7
9
%
13' - 12"
PVC @
13.11%
MI
L
B
U
R
N
R
O
A
D
CL
PRESCRIPTIVE
EASEMENT
224' - 36" RCP III @ 1
.
1
4
%
SEE NOTE V27 ON SHEET 2
FOR ADDITIONAL REQUIREMENTS.
ST
O
R
M
S
E
W
E
R
P
R
O
F
I
L
E
S
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
06 10/21/2019
38
06/28/2019
TTC
19-09
59
2760GC
V: 1" = 5'
H: 1" = 50'
101
113 114
115 116 117 118 119 120 121
9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50
590
595
600
605
610
615
620
625
630
635
640
645
590
595
600
605
610
615
620
625
630
635
640
645
STR 101 - STR 121
99' - 30" ADS N-12
@ 0.52%
163' - 24" ADS N-12
@
1
.
2
5
%
114' - 24" AD
S
N
-
1
2
@ 2.00%
106' - 24" ADS N-12
@ 0.50%
120' - 24" ADS N-12 @ 0.50%
120' - 18" ADS
N
-
1
2
@
1
.
7
5
%
120' - 18" ADS N-12 @ 0.75%
120' - 15" ADS N-12 @ 0.75%
112' - 15" ADS N-12
@ 0.50%
EXISTING
GRADE
EXISTING
GRADE
PROPOSED
GRADE
PROPOSED
GRADE
HGL
HGL
12
"
W
A
T
E
R
L
I
N
E
10
+
0
0
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(6
0
"
B
A
S
E
)
IN
V
O
U
T
=
6
0
7
.
5
6
(
3
6
"
)
IN
V
I
N
=
6
0
7
.
6
6
(
3
0
"
)
IN
V
I
N
=
6
0
7
.
6
6
(
3
0
"
)
10
+
9
8
.
6
7
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(6
0
"
B
A
S
E
)
IN
V
O
U
T
=
6
0
8
.
1
7
(
3
0
"
)
IN
V
I
N
=
6
0
9
.
7
7
(
2
4
"
)
12
+
6
1
.
5
2
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(6
0
"
B
A
S
E
)
IN
V
O
U
T
=
6
1
1
.
8
1
(
2
4
"
)
IN
V
I
N
=
6
1
2
.
9
1
(
2
4
"
)
13
+
7
5
.
4
6
=
M
H
-
1
(6
0
"
B
A
S
E
)
IN
V
O
U
T
=
6
1
5
.
1
9
(
2
4
"
)
IN
V
I
N
=
6
1
6
.
3
4
(
2
4
"
)
IN
V
I
N
=
6
1
6
.
6
9
(
1
8
"
)
14
+
8
1
.
6
0
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(4
8
"
B
A
S
E
)
IN
V
O
U
T
=
6
1
6
.
8
7
(
2
4
"
)
IN
V
I
N
=
6
1
6
.
9
7
(
2
4
"
)
16
+
0
1
.
6
2
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
IN
V
O
U
T
=
6
1
7
.
5
7
(
2
4
"
)
IN
V
I
N
=
6
1
8
.
6
7
(
1
8
"
)
17
+
2
1
.
6
2
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(4
8
"
B
A
S
E
)
IN
V
O
U
T
=
6
2
0
.
7
7
(
1
8
"
)
IN
V
I
N
=
6
2
1
.
3
7
(
1
8
"
)
18
+
4
1
.
6
2
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(4
8
"
B
A
S
E
)
IN
V
O
U
T
=
6
2
2
.
2
7
(
1
8
"
)
IN
V
I
N
=
6
2
2
.
6
2
(
1
5
"
)
19
+
6
1
.
6
2
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(4
8
"
B
A
S
E
)
IN
V
O
U
T
=
6
2
3
.
5
2
(
1
5
"
)
IN
V
I
N
=
6
2
3
.
6
2
(
1
5
"
)
20
+
7
3
.
9
6
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(4
8
"
B
A
S
E
)
IN
V
O
U
T
=
6
2
4
.
1
8
(
1
5
"
)
TO
P
=
6
1
8
.
8
5
TO
P
=
6
2
0
.
3
3
TO
P
=
6
2
3
.
4
2
TO
P
=
6
2
7
.
1
1
TO
P
=
6
2
6
.
9
5
TO
P
=
6
2
6
.
9
5
TO
P
=
6
2
6
.
9
4
TO
P
=
6
2
6
.
9
5
TO
P
=
6
2
6
.
9
5
TO
P
=
6
2
6
.
9
5
1.
2
5
"
S
A
N
I
T
A
R
Y
X-
I
N
G
ST
O
R
M
S
E
W
E
R
P
R
O
F
I
L
E
S
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
39
06/28/2019
TTC
19-09
59
2760GC
V: 1" = 5'
H: 1" = 50'
102 D10 D11 D12 D13
D14
D15
RD15
108 D1
D2 D3 D4
RD4
108
111 115
D16 D17 D18 D20D19
D21 D22
RD22
122
123
RD8
9+50 10+00 10+50 11+00 11+50
605
610
615
620
625
630
635
640
645
605
610
615
620
625
630
635
640
645
9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00
600
605
610
615
620
625
630
635
640
600
605
610
615
620
625
630
635
640
-0+50 0+00 0+50 1+00 1+50
600
605
610
615
620
625
630
635
640
600
605
610
615
620
625
630
635
640
-0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00
600
605
610
615
620
625
630
635
640
600
605
610
615
620
625
630
635
640
-0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00
605
610
615
620
625
630
635
640
645
600
605
610
615
620
625
630
635
640
645
STR 122 - STR 123
ROOF DRAIN STR 108 - D4
61' - 15"
RCP III
@ 1.02%
26'
-
12"
AD
S
N
-
1
2
@
1
4
.
0
4
%
17'
-
1
2
"
PVC
@
1
3
.
7
3
%
98' - 12" P
V
C
@
3
.
0
0
%
104' - 12" PVC @ 1.00%
98' - 12" PVC @ 1.00%
7' - 12"
PVC
@ 0.42%
77' - 15" A
D
S
N
-
1
2
@ 2.96%
109' - 18" ADS
N
-
1
2
@ 1.67%
104' - 18" ADS N-12
@ 0.75%
104' - 15" ADS N-12
@ 1.25%
104' - 15" ADS N-12
@ 0.75%
104' - 12" PVC @ 1.
2
5
%
104' - 12" PVC @ 0.50%
14' -
12"
PVC
@
8
.
3
1
%
66' - 18"
ADS N-12
@ 2.00%
104' - 18" ADS N-12
@ 0.75%
104' - 18" ADS N-12
@ 0.75%
104' - 15" ADS N-12
@ 1.25%
104' - 15" ADS N-12
@ 0.75%
104' - 12" PVC @ 1.00%
104' - 12" PVC @ 0.50%
21'
-
12"
PVC
@
1
3
.
6
7
%
EXISTING
GRADE
PROPOSED
GRADE
HGL
PROPOSED
GRADE
EXISTING
GRADE
HGL
ROOF DRAIN STR 102 - RD4
STR 108 - STR 111 ROOF DRAIN STR 115 - RD22
PROPOSED
GRADE
EXISTING
GRADE
HGL
PROPOSED
GRADE
EXISTING
GRADE
HGL
PROPOSED
GRADE
EXISTING
GRADE
HGL
PROPOSED
GRADE
HGL
HGL
PROPOSED
GRADE
EXISTING
GRADE
EXISTING
GRADE
12
"
W
/
L
X-
I
N
G
18"
MIN.
0+
0
0
.
0
0
=
M
H
-
1
(
6
0
"
B
A
S
E
)
IN
V
O
U
T
=
6
0
9
.
3
3
(
3
0
"
)
IN
V
I
N
=
6
1
4
.
9
3
(
1
8
"
)
IN
V
I
N
=
6
0
9
.
4
3
(
3
0
"
)
IN
V
I
N
=
6
1
7
.
9
3
(
1
2
"
)
1+
0
9
.
2
1
=
N
Y
P
-
1
8
"
W
/
S
O
L
I
D
C
O
V
E
R
IN
V
O
U
T
=
6
1
6
.
7
5
(
1
8
"
)
IN
V
I
N
=
6
1
6
.
7
5
(
1
8
"
)
IN
V
I
N
=
6
2
0
.
7
5
(
1
2
"
)
2+
1
3
.
2
1
=
N
Y
P
-
1
8
"
W
/
S
O
L
I
D
C
O
V
E
R
IN
V
O
U
T
=
6
1
7
.
5
3
(
1
8
"
)
IN
V
I
N
=
6
1
7
.
5
3
(
1
5
"
)
IN
V
I
N
=
6
2
1
.
5
3
(
1
2
"
)
3+
1
7
.
2
1
=
N
Y
P
-
1
5
"
W
/
S
O
L
I
D
C
O
V
E
R
IN
V
O
U
T
=
6
1
8
.
8
3
(
1
5
"
)
IN
V
I
N
=
6
1
8
.
8
3
(
1
5
"
)
IN
V
I
N
=
6
2
1
.
8
3
(
1
2
"
)
4+
2
1
.
2
1
=
N
Y
P
-
1
5
"
W
/
S
O
L
I
D
C
O
V
E
R
IN
V
O
U
T
=
6
1
9
.
6
1
(
1
5
"
)
IN
V
I
N
=
6
1
9
.
8
6
(
1
2
"
)
IN
V
I
N
=
6
2
1
.
6
1
(
1
2
"
)
5+
2
5
.
2
1
=
1
2
"
W
y
e
IN
V
=
6
2
1
.
1
6
6+
2
9
.
2
1
=
1
2
"
4
5
°
B
e
n
d
IN
V
O
U
T
=
6
2
1
.
6
8
IN
V
I
N
=
6
2
1
.
6
8
6+
4
3
.
3
5
=
R
O
O
F
D
R
A
I
N
IN
V
O
U
T
=
6
2
2
.
8
5
TO
P
=
6
2
6
.
2
8
TO
P
=
6
2
6
.
5
9
TO
P
=
6
2
6
.
5
9
TO
P
=
6
2
6
.
5
9
TO
P
=
6
2
6
.
5
9
TO
P
=
6
2
3
.
1
4
TO
P
=
6
2
3
.
1
4
TO
P
=
6
2
1
.
3
3
TO
P
=
6
2
7
.
1
1
TO
P
=
6
3
0
.
0
0
TO
P
=
6
2
9
.
7
8
TO
P
=
6
3
0
.
4
5
TO
P
=
6
2
9
.
7
8
TO
P
=
6
2
9
.
7
8
TO
P
=
6
2
2
.
0
0
TO
P
=
6
2
6
.
1
2
10
+
0
0
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
IN
V
O
U
T
=
6
1
3
.
8
0
(
2
4
"
)
IN
V
I
N
=
6
2
0
.
2
4
(
1
2
"
)
IN
V
I
N
=
6
1
4
.
0
5
(
1
5
"
)
IN
V
I
N
=
6
1
4
.
0
5
(
1
5
"
)
10
+
1
6
.
5
7
=
1
2
"
W
y
e
IN
V
=
6
2
2
.
5
1
11
+
1
4
.
5
7
=
1
2
"
W
y
e
IN
V
=
6
2
5
.
4
5
12
+
1
8
.
5
7
=
1
2
"
W
y
e
IN
V
=
6
2
6
.
4
9
13
+
1
6
.
5
7
=
1
2
"
4
5
°
B
e
n
d
IN
V
=
6
2
7
.
4
7
13
+
2
3
.
6
4
=
R
O
O
F
D
R
A
I
N
IN
V
O
U
T
=
6
2
7
.
4
7
7+
1
1
.
5
7
=
R
O
O
F
D
R
A
I
N
IN
V
=
6
2
8
.
1
8
6+
9
0
.
3
6
=
1
2
"
4
5
°
B
e
n
d
IN
V
=
6
2
5
.
2
8
5+
8
6
.
3
6
=
1
2
"
W
y
e
IN
V
=
6
2
4
.
7
6
(
1
2
"
)
4+
8
2
.
3
6
=
N
Y
P
-
1
5
"
W
/
S
O
L
I
D
C
O
V
E
R
IN
V
O
U
T
=
6
2
3
.
2
2
(
1
5
"
)
IN
V
I
N
=
6
2
3
.
7
2
(
1
2
"
)
IN
V
I
N
=
6
2
5
.
4
7
(
1
2
"
)
3+
7
8
.
3
6
=
N
Y
P
-
1
5
"
W
/
S
O
L
I
D
C
O
V
E
R
IN
V
O
U
T
=
6
2
2
.
3
4
(
1
5
"
)
IN
V
I
N
=
6
2
2
.
4
4
(
1
5
"
)
IN
V
I
N
=
6
2
5
.
3
4
(
1
2
"
)
2+
7
4
.
3
6
=
N
Y
P
-
1
8
"
W
/
S
O
L
I
D
C
O
V
E
R
IN
V
O
U
T
=
6
2
0
.
7
7
(
1
8
"
)
IN
V
I
N
=
6
2
1
.
0
4
(
1
5
"
)
IN
V
I
N
=
6
2
5
.
4
4
(
1
2
"
)
1+
7
0
.
3
6
=
N
Y
P
-
1
8
"
W
/
S
O
L
I
D
C
O
V
E
R
IN
V
O
U
T
=
6
1
9
.
3
9
(
1
8
"
)
IN
V
I
N
=
6
1
9
.
9
9
(
1
8
"
)
IN
V
I
N
=
6
2
4
.
8
9
(
1
2
"
)
0+
6
6
.
3
5
=
N
Y
P
-
2
4
"
W
/
S
O
L
I
D
C
O
V
E
R
IN
V
O
U
T
=
6
1
8
.
0
1
(
1
8
"
)
IN
V
I
N
=
6
1
8
.
6
1
(
1
8
"
)
IN
V
I
N
=
6
2
4
.
5
1
(
1
2
"
)
0+
0
0
.
0
0
=
M
H
1
(
6
0
"
B
A
S
E
)
IN
V
O
U
T
=
6
1
5
.
1
9
(
2
4
"
)
IN
V
I
N
=
6
1
6
.
6
9
(
1
8
"
)
IN
V
I
N
=
6
1
6
.
3
4
(
2
4
"
)
0+
0
0
.
0
0
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(6
0
"
B
A
S
E
)
IN
V
O
U
T
=
6
1
3
.
8
0
IN
V
I
N
=
6
1
4
.
0
5
(
1
5
"
)
IN
V
I
N
=
6
1
4
.
0
5
(
1
5
"
)
IN
V
I
N
=
6
2
0
.
2
4
(
1
2
"
)
0+
7
6
.
9
5
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(4
8
"
B
A
S
E
)
IN
V
O
U
T
=
6
1
6
.
3
3
10
+
8
6
.
8
7
=
R
O
O
F
D
R
A
I
N
IN
V
=
6
2
6
.
5
0
10
+
6
1
.
0
2
=
D
I
-
7
-
T
Y
P
E
I
I
G
R
A
T
E
(4
8
"
B
A
S
E
)
IN
V
O
U
T
=
6
2
2
.
6
2
(
1
5
"
)
IN
V
I
N
=
6
2
2
.
8
7
(
1
2
"
)
10
+
0
0
=
A
D
S
F
l
a
r
e
d
E
n
d
S
e
c
t
i
o
n
W
/
E
S
-
1
IN
V
O
U
T
=
6
2
2
.
0
0
5' CL A1
RIP RAP
1.
5
"
S
A
N
I
T
A
R
Y
X
-
I
N
G
12
"
W
/
L
X-
I
N
G
6"
W
/
L
X-
I
N
G
ST
O
R
M
S
E
W
E
R
P
R
O
F
I
L
E
S
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
40
06/28/2019
TTC
19-09
59
2760GC
V: 1" = 5'
H: 1" = 50'
BC1 BC2
CV1 CV2
CV3
CV4
CV5
CV6
-0+50 0+00 0+50 1+00 1+50
605
610
615
620
625
630
635
605
610
615
620
625
630
635
-0+50 0+00 0+50 1+00
605
610
615
620
625
630
635
605
610
615
620
625
630
635
-0+50 0+00 0+50 1+00
605
610
615
620
625
630
635
605
610
615
620
625
630
635
56' - 36" X 60"
DBL BOX
CULVERT @ 0.89%
41' - 34" x 53"
TWIN ELIP RC
P
I
I
I
@ 1.72%
13' -
15"
ADS
N
-
1
2
@ 7
.
9
6
%
Culvert Design Tue Jun 25 13:57:57 2019
Design Parameters
Section
Shape: Circular
Material: ADS N-12
Diameter: 15.00 in
Manning's n: 0.0120
Number of Barrels: 2
Inlet
Inlet Type: End Section
Ke: 0.40
Inverts
Inlet Invert Elevation: 620.360 ft
Outlet Invert Elevation: 619.320 ft
Length: 13.070 ft
Slope: 7.96 %
Culvert Calculation
Discharge: 2.2700 cfs
Headwater Elevation: 620.994 ft
Tailwater Elevation: 0.000 ft
Downstream Velocity: 8.74 ft/s
Downstream Flow Depth: 0.203 ft
Flow Control Type: HY8 Inlet Control
Culvert Design Mon Sep 9 12:43:14 2019
Design Parameters
Section
Shape: Circular
Material: Concrete
Diameter: 42.00 in
Manning's n: 0.0130
Number of Barrels: 2
Inlet
Inlet Type: Square Edge, 30 to 75 Degree Wingwall Flares
Ke: 0.40
Inverts
Inlet Invert Elevation: 616.200 ft
Outlet Invert Elevation: 615.500 ft
Length: 51.000 ft
Slope: 1.37 %
Culvert Calculation
Discharge: 126.0496 cfs
Headwater Elevation: 620.500 ft
Tailwater Elevation: 0.000 ft
Downstream Velocity: 12.46 ft/s
Downstream Flow Depth: 1.821 ft
Flow Control Type: Inlet Control, Unsub/submerged
Culvert Design Tue Jun 25 13:43:38 2019
Design Parameters
Section
Shape: Box
Material: Concrete
Rise: 36.00 in
Width: 60.00 in
Manning's n: 0.0130
Number of Barrels: 2
Inlet
Inlet Type: Square Edge, 30 to 75 Degree Wingwall Flares
Ke: 0.40
Inverts
Inlet Invert Elevation: 620.000 ft
Outlet Invert Elevation: 619.500 ft
Length: 56.000 ft
Slope: 0.89 %
Culvert Calculation
Discharge: 126.4700 cfs
Headwater Elevation: 622.631 ft
Tailwater Elevation: 0.000 ft
Downstream Velocity: 9.73 ft/s
Downstream Flow Depth: 1.300 ft
Flow Control Type: HY8 Inlet Control
BC 1 - BC 2 CV 1 - CV 2 CV 3 - CV 4
PROPOSED
GRADE EXISTING
GRADE
HGL PROPOSED
GRADE
EXISTING
GRADE HGL
PROPOSED
GRADE
EXISTING
GRADE
HGL
TO
P
=
6
2
5
.
9
2
TO
P
=
6
2
6
.
4
2
TO
P
=
6
2
1
.
5
0
TO
P
=
6
2
2
.
2
0
TO
P
=
6
2
3
.
0
0
TO
P
=
6
1
9
.
3
2
0+
0
0
.
0
0
=
B
C
W
-
2
1
(
W
I
N
G
W
A
L
L
S
)
IN
V
O
U
T
=
6
1
9
.
5
0
0+
5
6
.
0
6
=
B
C
W
-
2
1
(
W
I
N
G
W
A
L
L
S
)
IN
V
I
N
=
6
2
0
.
0
0
0+
0
0
.
0
0
=
E
W
-
6
IN
V
O
U
T
=
6
1
5
.
5
0
0+
0
0
.
0
0
=
E
W
-
1
IN
V
O
U
T
=
6
1
9
.
3
2
0+
1
3
.
0
7
=
E
W
-
1
IN
V
I
N
=
6
2
0
.
3
6
20' CL I
RIP RAP
20' CL I RIP
RAP
5' CL I RIP
RAP
C/
L
M
I
L
B
U
R
N
R
D
-0+50 0+00 0+50 1+00
605
610
615
620
625
630
635
605
610
615
620
625
630
635
22' -
15"
ADS N-12
@ 1.18%
0+
0
0
.
0
0
=
E
S
-
1
IN
V
O
U
T
=
6
1
9
.
6
1
0+
2
6
.
2
5
IN
V
I
N
=
6
1
9
.
8
7
TO
P
=
6
1
9
.
6
1
TO
P
=
6
2
1
.
2
1
HGLPROPOSED
GRADE
EXISTING
GRADE
Culvert Design Fri Oct 18 10:35:21 2019
Design Parameters
Section
Shape: Circular
Material: ADS N-12
Diameter: 15.00 in
Manning's n: 0.0120
Number of Barrels: 1
Inlet
Inlet Type:
Ke: 0.70
Inverts
Inlet Invert Elevation: 619.870 ft
Outlet Invert Elevation: 619.610 ft
Length: 22.300 ft
Slope: 1.17 %
Culvert Calculation
Discharge: 2.5182 cfs
Headwater Elevation: 620.693 ft
Tailwater Elevation: 0.000 ft
Downstream Velocity: 7.91 ft/s
Downstream Flow Depth: 1.170 ft
Flow Control Type: HY8 Outlet Control
CV 5 - CV 6
51' - 34" x 53"
TWIN ELIP RCP II
I
@ 1.38%
0+
5
0
.
6
1
=
E
W
-
6
IN
V
I
N
=
6
1
6
.
2
0
PRESCRIPTIVE
EASEMENT
PIPE MAY NOT
EXTEND INTO
EASEMENT, TIE
EX. ROADSIDE
DITCH INTO
PROP. INVERT
ST
O
R
M
S
E
W
E
R
P
R
O
F
I
L
E
S
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
06 10/21/2019
41
06/28/2019
TTC
19-09
59
2760GC
V: 1" = 5'
H: 1" = 50'
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
ST
O
R
M
S
E
W
E
R
C
A
L
C
U
L
A
T
I
O
N
S
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
Rev. No. Date
04 09/17/2019
N/A
42
06/28/2019
TTC
19-09
59
2760GC
STORM SEWER PIPE CALCULATIONS
From To
DA
(Acres)
Runoff
Coef.
C
CA
(Increm.)
CA
(Accum.)
Tc
(min)
Rainfall
(in/hr)
Runoff Q,
(cfs)
Invert
Up
(ft)
Invert
Down
(ft)
Length
(ft)
Slope
(%)
Diameter
(in)
Capacity
(cfs)
Velocity
(fps)
Increm
Flow Time
(min)
Flow Time
(min)
Pipe
Material
STR 110 STR 109 0.74 0.48 0.36 0.36 5 6.50 2.32 619.02 614.94 120.18 3.39 15 13.87 1.89 0.25 1.06 ADS N-12
STR 109 STR 108 0.84 0.35 0.30 0.65 5 6.50 3.98 614.84 614.05 143.86 0.55 15 5.57 3.24 0.51 0.70 ADS N-12
STR 111 STR 108 0.48 0.30 0.14 0.14 5 6.50 0.93 616.33 614.05 76.95 2.96 15 12.96 0.76 0.22 1.69 ADS N-12
RD 4 D4 0.11 0.85 0.09 0.09 5 6.50 0.61 627.50 627.47 7.07 0.42 12 2.70 2.64 0.04 0.04 PVC
D4 D3 0.00 0.00 0.00 0.09 0 0.00 0.61 627.47 626.49 98.00 1.00 12 4.15 3.59 0.45 0.45 PVC
RD 3 D3 0.25 0.85 0.21 0.21 5 6.50 1.39 627.00 626.49 7.07 7.21 12 11.15 9.18 0.01 0.01 PVC
D3 D2 0.00 0.00 0.00 0.31 0 0.00 1.94 626.49 625.45 104.00 1.00 12 4.15 4.92 0.35 0.35 PVC
RD 2 D2 0.25 0.85 0.21 0.21 5 6.50 1.39 626.50 625.45 7.07 14.85 12 16.00 11.86 0.01 0.01 PVC
D2 D1 0.00 0.00 0.00 0.52 0 0.00 3.21 625.45 622.51 98.00 3.00 12 7.19 4.09 0.19 0.40 PVC
RD 1 D1 0.11 0.85 0.09 0.09 5 6.50 0.61 624.00 622.51 7.07 21.07 12 19.06 10.53 0.01 0.01 PVC
D1 STR 108 0.00 0.00 0.00 0.61 0 0.00 3.70 622.51 620.24 16.57 13.70 12 15.37 4.77 0.02 0.06 PVC
STR 108 STR 107 1.20 0.57 0.68 2.09 5 6.50 12.25 613.80 613.16 128.64 0.50 24 18.59 3.90 0.36 0.53 ADS N-12
STR 107 STR 106 0.64 0.79 0.51 2.60 5 6.50 14.79 613.06 612.25 134.75 0.60 24 20.42 4.71 0.33 0.45 ADS N-12
RD 7 D8 0.25 0.85 0.21 0.21 5 6.50 1.38 626.50 624.83 12.74 13.11 12 15.03 11.35 0.02 0.02 PVC
D8 D7 0.00 0.00 0.00 0.21 0 0.00 1.39 624.83 621.93 104.00 2.79 12 6.94 6.54 0.26 0.26 PVC
RD 6 D7 0.25 0.85 0.21 0.21 5 6.50 1.38 622.00 621.93 12.73 0.56 12 3.10 3.64 0.06 0.06 PVC
D7 D6 0.00 0.00 0.00 0.43 0 0.00 2.72 621.93 620.47 72.84 2.00 12 5.87 6.95 0.17 0.17 PVC
D6 D5 0.00 0.00 0.00 0.43 0 0.00 2.69 620.47 619.28 22.85 5.19 12 9.46 9.84 0.04 0.04 PVC
RD 5 D5 0.11 0.85 0.09 0.09 5 6.50 0.61 624.73 619.28 25.16 21.66 12 19.32 10.63 0.04 0.04 PVC
D5 STR 106 0.00 0.00 0.00 0.52 0 0.00 3.28 619.28 618.32 30.26 3.18 12 7.40 8.66 0.06 0.06 PVC
STR 106 STR 104 0.67 0.79 0.53 3.65 5 6.50 20.25 611.75 611.03 144.61 0.50 30 33.80 4.13 0.35 0.55 ADS N-12
STR 112 STR 104 1.11 0.68 0.75 0.75 5 6.50 4.91 619.58 617.25 25.70 9.05 15 22.65 13.98 0.03 0.03 ADS N-12
STR 104 STR 103 0.78 0.76 0.60 5.00 5 6.50 26.99 610.93 610.37 93.55 0.60 30 37.03 5.50 0.20 0.27 ADS N-12
STR 103 STR 102 0.24 0.58 0.14 5.14 5 6.50 27.40 610.27 609.43 140.29 0.60 30 37.02 5.58 0.30 0.39 ADS N-12
RD 15 D15 0.31 0.85 0.26 0.26 5 6.50 1.71 622.85 621.68 14.14 8.31 12 11.97 2.18 0.02 0.11 PVC
D15 D14 0.00 0.00 0.00 0.26 0 0.00 1.71 621.68 621.16 104.00 0.50 12 2.94 2.18 0.47 0.79 PVC
RD 14 D14 0.31 0.85 0.26 0.26 5 6.50 1.71 622.35 621.16 14.14 8.45 12 12.07 2.18 0.02 0.11 PVC
D14 D13 0.00 0.00 0.00 0.53 0 0.00 3.25 621.16 619.86 104.00 1.25 12 4.63 4.13 0.29 0.41 PVC
RD 13 D13 0.31 0.85 0.26 0.26 5 6.50 1.71 622.35 621.61 14.14 5.24 12 9.51 8.71 0.03 0.03 PVC
D13 D12 0.00 0.85 0.00 0.79 5 6.50 4.75 619.61 618.83 104.00 0.75 15 6.52 3.87 0.32 0.43 ADS N-12
RD 12 D12 0.31 0.85 0.26 0.26 5 6.50 1.71 622.35 621.83 14.14 3.69 12 7.97 7.68 0.03 0.03 PVC
D12 D11 0.00 0.85 0.00 1.06 5 6.50 6.18 618.83 617.53 104.00 1.25 15 8.42 5.04 0.24 0.33 ADS N-12
RD 11 D11 0.31 0.85 0.26 0.26 5 6.50 1.71 622.35 621.53 14.14 5.81 12 10.01 9.04 0.03 0.03 PVC
D11 D10 0.00 0.85 0.00 1.32 5 6.50 7.59 617.53 616.75 104.00 0.75 18 10.60 4.48 0.28 0.39 ADS N-12
RD 10 D10 0.31 0.85 0.26 0.26 5 6.50 1.71 622.35 620.75 14.14 11.32 12 13.97 11.46 0.02 0.02 PVC
D10 STR 102 0.00 0.85 0.00 1.58 5 6.50 8.92 616.75 614.93 109.21 1.67 18 15.82 8.81 0.21 0.21 ADS N-12
RD 9 STR 102 0.16 0.85 0.13 0.13 5 6.50 0.86 626.97 617.93 36.30 24.90 12 20.72 12.35 0.05 0.05 PVC
STR 102 STR 101 0.00 0.50 0.00 6.85 5 6.50 35.87 609.33 607.66 168.78 0.99 30 47.48 7.31 0.28 0.36 ADS N-12
STR 121 STR 120 0.41 0.55 0.22 0.22 5 6.50 1.45 624.18 623.62 112.33 0.50 15 5.32 3.50 0.53 0.53 ADS N-12
STR 120 STR 119 0.72 0.77 0.55 0.78 5 6.50 4.89 623.52 622.62 120.00 0.75 15 6.52 5.50 0.36 0.36 ADS N-12
STR 119 STR 118 0.76 0.78 0.59 1.37 5 6.50 8.42 622.27 621.37 120.01 0.75 18 10.60 6.26 0.32 0.32 ADS N-12
STR 118 STR 117 0.76 0.78 0.59 1.96 5 6.50 11.82 620.77 618.67 119.99 1.75 18 16.19 6.69 0.21 0.30 ADS N-12
STR 117 STR 116 0.76 0.78 0.59 2.55 5 6.50 15.12 617.57 616.97 120.02 0.50 24 18.64 4.84 0.32 0.41 ADS N-12
STR 116 STR 115 0.78 0.78 0.61 3.16 5 6.50 18.32 616.87 616.34 106.14 0.50 24 18.63 5.89 0.30 0.30 ADS N-12
RD 22 D22 0.31 0.85 0.26 0.26 5 6.50 1.71 628.18 625.28 21.21 13.67 12 15.35 2.18 0.03 0.16 PVC
D22 D21 0.00 0.00 0.00 0.26 0 0.00 1.70 625.28 624.76 104.00 0.50 12 2.94 2.16 0.47 0.79 PVC
RD 21 D21 0.31 0.85 0.26 0.26 5 6.50 1.71 627.68 624.76 21.21 13.76 12 15.40 2.18 0.03 0.16 PVC
D21 D20 0.00 0.00 0.00 0.53 0 0.00 3.24 624.76 623.72 104.00 1.00 12 4.15 4.12 0.31 0.41 PVC
RD 20 D20 0.31 0.85 0.26 0.26 5 6.50 1.71 627.68 625.47 21.21 10.42 12 13.40 11.13 0.03 0.03 PVC
D20 D19 0.00 0.50 0.00 0.79 0 0.00 4.74 623.22 622.44 104.00 0.75 15 6.52 3.86 0.32 0.43 ADS N-12
RD 19 D19 0.31 0.85 0.26 0.26 5 6.50 1.71 627.68 625.34 21.21 11.03 12 13.79 11.36 0.03 0.03 PVC
D19 D18 0.00 0.50 0.00 1.06 0 0.00 6.16 622.34 621.04 104.00 1.25 15 8.42 5.02 0.24 0.33 ADS N-12
RD 18 D18 0.31 0.85 0.26 0.26 5 6.50 1.71 627.68 625.44 21.21 10.54 12 13.48 11.18 0.03 0.03 PVC
D18 D17 0.00 0.50 0.00 1.32 0 0.00 7.57 620.77 619.99 104.00 0.75 18 10.62 4.28 0.28 0.39 ADS N-12
RD 17 D17 0.31 0.85 0.26 0.26 5 6.50 1.71 627.68 624.89 21.21 13.15 12 15.06 12.09 0.03 0.03 PVC
D17 D16 0.00 0.50 0.00 1.58 0 0.00 8.90 619.39 618.61 104.00 0.75 18 10.60 5.03 0.27 0.33 ADS N-12
RD 16 D16 0.16 0.85 0.13 0.13 5 6.50 0.86 627.14 624.51 21.21 12.42 12 14.63 9.67 0.04 0.04 PVC
D16 STR 115 0.00 0.50 0.00 1.71 0 0.00 9.48 618.01 616.69 66.35 1.99 18 17.27 5.63 0.12 0.20 ADS N-12
STR 115 STR 114 0.00 0.50 0.00 4.87 0 0.00 26.67 615.19 612.91 113.94 2.00 24 37.26 8.49 0.15 0.21 ADS N-12
STR 114 STR 113 0.64 0.51 0.33 5.20 5 6.50 28.15 611.81 609.77 162.85 1.25 24 29.51 8.96 0.29 0.29 ADS N-12
STR 113 STR 101 0.92 0.39 0.36 5.56 5 6.50 29.68 608.17 607.66 98.67 0.52 30 34.36 6.05 0.22 0.26 ADS N-12
STR 101 STR 100B 0.60 0.43 0.26 12.67 5 6.50 65.24 607.56 606.32 124.39 1.00 36 71.75 9.23 0.21 0.21 RCP III
STR 100B STR 100A 0.22 0.30 0.07 12.73 5 6.50 64.97 606.22 606.02 19.71 1.00 36 71.74 9.84 0.03 0.03 RCP III
STR 100A STR 100 0.02 0.30 0.01 12.74 5 6.50 64.91 605.92 605.00 79.83 1.15 36 77.03 11.54 0.12 0.12 RCP III
HYDRAULIC GRADE LINE CALCULATIONS
Inlet
No.
Outlet
W.S.E.
(ft)
Do
(in)
Qo
(cfs)
Lo
(ft)
Sfo
(%)
Hf
(ft)
JUNCTION LOSS Final
H
(ft)
Inlet
W.S.E.
(ft)
Rim
Elev
(ft)Vo
(fps)
Ho
(ft)
Qi
(cfs)
Vi
(fps)QiVi Vi^2/2g Hi
(ft)
Angle
(deg)K Hb
(ft)
Ht
(ft)
1.3Ht
(ft)
0.5Ht
(ft)
STR 100B 609.20 36 64.97 19.71 0.94 0.19 9.84 0.30 0.49 609.69 616.50
STR 100A 607.40 36 64.91 79.83 0.99 0.79 11.54 0.41 1.20 608.60 616.50
STR 101 610.30 36 65.24 124.39 0.95 1.18 9.23 0.33 35.87 7.31 262.16 0.83 0.29 86 0.7 0.58 1.21 0.60 1.79 612.08
29.68 6.05 179.43 0.57 78 0.7 0.38 618.85
STR 113 612.08 30 29.68 98.67 0.44 0.44 6.05 0.14 28.15 8.96 252.30 1.25 0.44 32 0.4 0.46 1.04 0.52 0.96 613.04 620.33
STR 114 613.04 24 28.15 162.85 1.31 2.14 8.96 0.31 26.67 8.49 226.36 1.12 0.39 84 0.7 0.78 1.48 0.74 2.88 615.92 621.50
STR 115 615.92 24 26.67 113.94 1.18 1.34 8.49 0.28 18.32 5.89 107.90 0.54 0.19 1 0.0 0.01 0.79 0.40 1.74 617.66
18.41 5.89 108.42 0.54 1 0.0 0.01 627.11
STR 116 617.94 24 18.32 106.14 0.58 0.62 5.89 0.13 15.12 4.84 73.13 0.36 0.13 0 0.0 0.00 0.26 0.34 0.17 0.79 618.73 626.95
STR 117 618.73 24 15.12 120.02 0.34 0.41 4.84 0.09 11.82 6.69 79.06 0.70 0.24 0 0.0 0.00 0.33 0.43 0.22 0.63 619.36 626.95
STR 118 619.87 18 11.82 119.99 1.12 1.35 6.69 0.17 8.42 6.26 52.72 0.61 0.21 0 0.0 0.00 0.39 0.50 0.25 1.60 621.47 626.94
STR 119 622.57 18 8.42 120.01 0.57 0.68 6.26 0.15 4.89 5.50 26.89 0.47 0.16 0 0.0 0.00 0.32 0.41 0.21 0.89 623.46 626.95
STR 120 623.62 15 4.89 120.00 0.51 0.61 5.50 0.12 1.45 3.50 5.09 0.19 0.07 0 0.0 0.00 0.18 0.24 0.12 0.73 624.35 626.95
STR 121 624.62 15 1.45 112.33 0.04 0.05 3.50 0.06 0.06 0.07 0.04 0.09 624.71 626.95
D16 617.89 18 9.48 66.35 0.72 0.48 5.63 0.12 0.86 9.67 8.29 1.45 0.15 31 0.4 0.52 0.80 0.40 0.88 618.77
8.90 5.28 46.93 0.43 76 0.7 0.29 630.00
RD 16 625.31 12 0.86 21.21 0.05 0.01 9.67 0.44 0.44 0.57 0.28 0.29 625.60 630.68
D17 619.81 18 8.90 104.00 0.64 0.66 5.03 0.10 1.71 12.09 20.73 2.27 0.11 45 0.5 1.07 1.27 0.64 1.30 621.11
7.57 4.47 33.80 0.31 0 0.0 0.00 629.78
RD 17 625.69 12 1.71 21.21 0.21 0.04 12.09 0.68 0.68 0.89 0.44 0.49 626.18 630.68
D18 621.19 18 7.57 104.00 0.46 0.48 4.28 0.07 1.71 11.18 19.17 1.94 0.14 45 0.5 0.91 1.12 1.46 0.73 1.21 622.40
6.16 5.02 30.97 0.39 0 0.0 0.00 630.45
RD 18 626.24 12 1.71 21.21 0.21 0.04 11.18 0.58 0.58 0.76 0.38 0.42 626.67 630.68
D19 622.40 15 6.16 104.00 0.77 0.80 5.02 0.10 1.71 11.36 19.48 2.01 0.70 45 0.5 0.94 1.74 2.26 1.13 1.94 624.33
4.74 3.86 18.30 0.23 0 0.0 0.00 629.78
RD 19 626.14 12 1.71 21.21 0.21 0.04 11.36 0.60 0.60 0.78 0.39 0.43 626.57 630.68
D20 624.33 15 4.74 104.00 0.46 0.47 3.86 0.06 1.71 11.13 19.08 1.93 0.67 45 0.5 0.90 1.64 2.13 1.06 1.54 625.87
3.24 4.12 13.33 0.26 0 0.0 0.00 629.78
RD 20 626.27 12 1.71 21.21 0.21 0.04 11.13 0.58 0.58 0.75 0.38 0.42 626.69 630.68
D21 625.87 12 3.24 104.00 0.70 0.73 4.12 0.07 1.71 2.18 3.74 0.07 0.03 45 0.5 0.03 0.13 0.06 0.79 626.66
1.70 2.16 3.68 0.07 0 0.0 0.00 629.78
RD 21 626.66 12 1.71 21.21 0.20 0.04 2.18 0.02 0.02 0.03 0.01 0.06 626.72 630.68
D22 626.66 12 1.70 104.00 0.19 0.20 2.16 0.02 1.71 2.18 3.74 0.07 0.03 45 0.5 0.03 0.08 0.04 0.24 626.90 629.78
RD 22 626.90 12 1.71 21.21 0.20 0.04 2.18 0.02 0.02 0.03 0.01 0.06 626.96 630.68
STR 102 612.08 30 35.87 168.78 0.65 1.09 7.31 0.21 0.86 12.35 10.59 2.37 0.17 62 0.6 1.35 1.72 2.24 1.12 2.21 614.30
8.92 8.81 78.65 1.21 61 0.6 0.69
0.86 12.35 10.59 2.37 62 0.6 1.35 626.28
STR 103 614.30 30 27.40 140.29 0.38 0.53 5.58 0.12 26.99 5.50 148.45 0.47 0.16 14 0.2 0.08 0.37 0.18 0.72 615.01 623.30
STR 104 615.01 30 26.99 93.55 0.37 0.34 5.50 0.12 4.91 13.98 68.59 3.04 0.09 61 0.6 1.71 1.92 0.96 1.31 616.32
20.25 4.13 83.57 0.26 32 0.4 0.10 623.15
STR 112 618.25 15 4.91 25.70 0.51 0.13 13.98 0.91 0.91 1.19 0.59 0.72 618.97 623.10
STR 106 616.32 30 20.25 144.61 0.21 0.30 4.13 0.07 3.28 8.66 28.43 1.17 0.12 46 0.5 0.55 0.74 0.37 0.67 616.99
14.79 4.71 69.61 0.34 0 0.0 0.00 623.15
STR 107 616.99 24 14.79 134.75 0.36 0.49 4.71 0.09 12.25 3.90 47.75 0.24 0.08 0 0.0 0.00 0.17 0.22 0.11 0.60 617.59 623.15
STR 108 617.59 24 12.25 128.64 0.25 0.32 3.90 0.06 3.70 4.77 17.69 0.35 0.12 90 0.7 0.25 0.44 0.57 0.28 0.60 618.19
3.98 3.24 12.89 0.16 28 0.3 0.05
3.70 4.77 17.69 0.35 90 0.7 0.25 623.14
STR 111 618.19 15 0.93 76.95 0.02 0.01 0.76 0.00 0.00 0.00 0.00 0.02 618.20 621.33
STR 109 618.19 15 3.98 143.86 0.32 0.46 3.24 0.04 2.32 1.89 4.39 0.06 0.02 41 0.4 0.02 0.08 0.11 0.06 0.52 618.71 617.84
STR 110 618.71 15 2.32 120.18 0.11 0.13 1.89 0.02 0.02 0.02 0.01 0.14 618.85 622.02
D1 621.04 12 3.70 16.57 0.96 0.16 4.77 0.09 0.61 10.53 6.45 1.72 0.09 45 0.5 0.81 0.99 0.49 0.65 621.69
3.21 4.09 13.13 0.26 0 0.0 0.00 628.42
RD 1 623.31 12 0.61 7.07 0.03 0.00 10.53 0.52 0.52 0.67 0.34 0.34 623.65 630.28
D2 623.31 12 3.21 98.00 0.72 0.71 4.09 0.06 1.39 11.86 16.43 2.19 0.76 45 0.5 1.03 1.86 0.93 1.64 624.95
1.94 4.92 9.54 0.38 0 0.0 0.00 630.03
RD 2 626.38 12 1.39 7.07 0.11 0.01 11.86 0.66 0.66 0.85 0.43 0.43 626.81 630.28
D3 626.38 12 1.94 104.00 0.22 0.23 4.92 0.09 1.39 9.18 12.72 1.31 0.46 45 0.5 0.62 1.17 0.58 0.81 627.19
0.61 3.59 2.20 0.20 0 0.0 0.00 630.03
RD 3 627.29 12 1.39 7.07 0.13 0.01 9.18 0.39 0.39 0.51 0.26 0.26 627.56 630.28
D4 627.29 12 0.61 98.00 0.03 0.03 3.59 0.05 0.61 2.64 1.62 0.11 0.04 45 0.5 0.05 0.14 0.07 0.10 627.39 630.44
RD 4 628.27 12 0.61 7.07 0.03 0.00 2.64 0.03 0.03 0.04 0.02 0.02 628.29 630.98
D5 619.12 12 3.28 30.26 0.75 0.23 8.66 0.29 0.61 10.63 6.51 1.76 0.53 45 0.5 0.83 1.65 0.82 1.05 620.17
2.69 9.84 26.52 1.51 0 0.0 0.01 627.01
RD 5 620.17 12 0.61 25.16 0.02 0.01 10.63 0.53 0.53 0.69 0.34 0.35 620.52 627.23
D6 620.17 12 2.69 22.85 0.43 0.10 9.84 0.38 2.72 6.95 18.93 0.75 0.26 45 0.5 0.35 0.99 0.50 0.59 620.77 626.90
D7 621.27 12 2.72 72.84 0.52 0.38 6.95 0.19 1.39 6.54 9.07 0.67 0.23 0 0.0 0.00 0.52 0.26 0.64 621.91
1.38 3.64 5.04 0.21 45 0.5 0.10 626.90
RD 6 622.73 12 1.38 12.73 0.13 0.02 3.64 0.06 0.06 0.08 0.04 0.06 622.78 626.99
D8 622.73 12 1.39 104.00 0.13 0.14 6.54 0.17 1.38 11.35 15.72 2.00 0.70 45 0.5 0.94 1.81 0.90 1.04 623.77 629.83
RD 7 625.73 12 1.38 12.74 0.11 0.01 11.35 0.60 0.60 0.78 0.39 0.40 626.14 630.28
RD 9 618.73 12 0.86 36.30 0.05 0.02 12.35 0.71 0.71 0.92 0.46 0.48 619.21 630.00
D10 616.13 18 8.92 109.21 0.64 0.70 8.81 0.30 1.71 11.46 19.66 2.04 0.11 32 0.4 0.75 1.16 0.58 1.28 617.41
7.59 4.48 33.97 0.31 13 0.2 0.05 626.59
RD 10 621.55 12 1.71 14.14 0.21 0.03 11.46 0.61 0.61 0.80 0.40 0.43 621.98 626.69
D11 617.95 18 7.59 104.00 0.46 0.48 4.48 0.08 1.71 9.04 15.49 1.27 0.14 45 0.5 0.60 0.81 1.06 0.53 1.01 618.96
6.18 5.04 31.16 0.39 0 0.0 0.00 626.59
RD 11 622.33 12 1.71 14.14 0.21 0.03 9.04 0.38 0.38 0.49 0.25 0.28 622.61 626.69
D12 618.96 15 6.18 104.00 0.78 0.81 5.04 0.10 1.71 7.68 13.16 0.92 0.08 45 0.5 0.43 0.61 0.79 0.40 1.20 620.16
4.75 3.87 18.41 0.23 0 0.0 0.00 626.59
RD 12 622.63 12 1.71 14.14 0.21 0.03 7.68 0.27 0.27 0.36 0.18 0.21 622.84 626.69
D13 620.16 15 4.75 104.00 0.46 0.48 3.87 0.06 1.71 8.71 14.94 1.18 0.41 45 0.5 0.55 1.03 1.33 0.67 1.14 621.31
3.25 4.13 13.42 0.27 0 0.0 0.00 626.59
RD 13 622.41 12 1.71 14.14 0.21 0.03 8.71 0.35 0.35 0.46 0.23 0.26 622.67 626.69
D14 621.31 12 3.25 104.00 0.70 0.73 4.13 0.07 1.71 2.18 3.73 0.07 0.03 0 0.0 0.00 0.13 0.06 0.80 622.10
1.71 2.18 3.74 0.07 45 0.5 0.03 626.59
RD 14 622.10 12 1.71 14.14 0.17 0.02 2.18 0.02 0.02 0.03 0.01 0.04 622.14 626.69
D15 622.10 12 1.71 104.00 0.17 0.17 2.18 0.02 1.71 2.18 3.74 0.07 0.03 45 0.5 0.03 0.08 0.04 0.21 622.32 626.59
RD 15 622.48 12 1.71 14.14 0.21 0.03 2.18 0.02 0.02 0.03 0.01 0.04 622.52 626.69
Curb Cut
No.
Width
(ft)
DA
(Ac.)CN Flow
(cfs)
Slope
(%)
Xslope
(%)
Spread
(ft)
Depth
(in)
CC 1 3 0.11 0.77 0.53 0.70 4.00 3.85 1.9
CC 2 3 0.11 0.77 0.53 0.70 4.00 3.85 1.9
CC 3 3 0.12 0.73 0.57 0.70 4.00 3.97 1.9
CC 4 3 0.20 0.75 0.95 0.70 4.00 5.58 2.7
CC 5 3 0.20 0.75 0.95 0.70 4.00 5.58 2.7
CC 6 3 0.20 0.75 0.95 0.70 4.00 5.58 2.7
CC 7 3 0.22 0.76 1.09 0.70 4.00 6.12 2.9
CC 8 3 0.22 0.76 1.09 0.70 4.00 6.12 2.9
10%8%10'
10'13'
1'
NOT TO SCALE
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 67.21 CFS --3.74 FPS
10 YR STORM EVENT: 92.53 CFS 1.17' --
CHANNEL SLOPE 1.50%
RIPRAP CHANNEL SECTION #2
VDOT CLASS AI RIPRAP
10'
7.2'
1.
2
'
1.
7
'
7.2'
8:1 8:1
NOT TO SCALE
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 67.21 CFS --3.31 FPS
10 YR STORM EVENT: 92.53 CFS 1.64' --
CHANNEL SLOPE 1.20%
GRASS CHANNEL SECTION #3
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
3:13:1
10'
1.
6
4
'
4.9'
NOT TO SCALE
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 3.02 CFS -- 1.61 FPS
10 YR STORM EVENT: 4.16 CFS 0.60' --
CHANNEL SLOPE 2.00%
GRASS CHANNEL SECTION #4
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
3:13:12'
3'3'
NOT TO SCALE
GRASS CHANNEL SECTION #5
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 1.00 CFS --2.14 FPS
10 YR STORM EVENT: 1.37 CFS 0.21' --
CHANNEL SLOPE 7.70%
NOT TO SCALE
GRASS CHANNEL SECTION #6
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 1.08 CFS -- 1.15 FPS
10 YR STORM EVENT: 1.50 CFS 0.34' --
CHANNEL SLOPE 2.50%
NOT TO SCALE
GRASS CHANNEL SECTION #7
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 1.08 CFS -- 1.32 FPS
10 YR STORM EVENT: 1.50 CFS 0.33' --
CHANNEL SLOPE 2.90%
NOT TO SCALE
GRASS CHANNEL SECTION #8
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 2.55 CFS --2.39 FPS
10 YR STORM EVENT: 3.53 CFS 0.40' --
CHANNEL SLOPE 4.60%
NOT TO SCALE
GRASS CHANNEL SECTION #9
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 2.55 CFS -- 1.61 FPS
10 YR STORM EVENT: 3.53 CFS 0.58' --
CHANNEL SLOPE 2.00%
NOT TO SCALE
GRASS CHANNEL SECTION #10
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 2.03 CFS -- 1.39 FPS
10 YR STORM EVENT: 2.90 CFS 0.52' --
CHANNEL SLOPE 2.00%
NOT TO SCALE
GRASS CHANNEL SECTION #11
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 5.40 CFS --2.00 FPS
10 YR STORM EVENT: 7.73 CFS 0.78' --
CHANNEL SLOPE 2.00%
NOT TO SCALE
GRASS CHANNEL SECTION #12
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 5.40 CFS --0.90 FPS
10 YR STORM EVENT: 7.73 CFS 1.29' --
CHANNEL SLOPE 0.50%
NOT TO SCALE
GRASS CHANNEL SECTION #13
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 0.13CFS --0.30 FPS
10 YR STORM EVENT: 0.17 CFS 0.09' --
CHANNEL SLOPE 2.00%
NOT TO SCALE
CONCRETE CHANNEL SECTION #14
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 0.80 CFS --5.46'
10 YR STORM EVENT: 1.10 CFS 0.03' --
CHANNEL SLOPE 28.00%
NOT TO SCALE
GRASS CHANNEL SECTION #15
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 248.43 CFS --7.18 FPS
10 YR STORM EVENT: 342.00 CFS 2.49' --
CHANNEL SLOPE 2.00%
NOT TO SCALE
RIPRAP CHANNEL SECTION #16
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 248.43 CFS --4.11 FPS
10 YR STORM EVENT: 342.00 CFS 3.65' --
CHANNEL SLOPE 0.43%
NOT TO SCALE
RIPRAP CHANNEL SECTION #1
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 67.21 CFS --4.71 FPS
10 YR STORM EVENT: 92.53 CFS 0.89' --
CHANNEL SLOPE 3.5%
3:1
1.
8
'
3.6'3.6'
1'
5:1
5'3'
3:1
3:1
1
.
5
'
3:1 2'
4'6.6'
1.
3
'
5:1
8%
HERE
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
3:1 2'
3.6'3.6'
1'3:1
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
2.5:1 2'
2.5'2'
2:1
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
3:1
2'
2'
10'3.6'
1
'3:1
2'
1
'
2'
1
'
2'
1
'
2'
2'2'
VDOT CLASS AI RIPRAP
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
3:13:12'
3'3'
1'
2'
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
3:13:12'
3'3'
1'
2'
4.9:1
1.
4
'
5.3'9'
9:1
5.3'
1
'
VDOT GC-6
VDOT CLASS A1 RIP RAP
3:13:1
10'
2.
5
'
7.5'7.5'
3:13:1
10'
3.
6
5
'
11'11''
VDOT CLASS AI RIPRAP
5.3'
2%2%
CLASS A3 CONCRETE
SEE CONCRETE SCUPPER
DETAIL ON SHEET 47.
1.
2
'
4.9'
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
DI
T
C
H
C
R
O
S
S
S
E
C
T
I
O
N
S
A
N
D
C
O
M
P
U
T
A
T
I
O
N
S
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
Rev. No. Date
04 09/17/2019
N/A
43
06/28/2019
TTC
19-09
59
2760GC
Area: 65.133 Acre
C: 0.344
Area: 65.133 Acre
C: 0.344
Area: 65.133 Acre
C: 0.344
Area: 3.834 Acre
C: 0.263
Area: 0.855 Acre
C: 0.269
Area: 0.855 Acre
C: 0.269
Area: 0.855 Acre
C: 0.269
Area: 1.176 Acre
C: 0.461
Area: 1.176 Acre
C: 0.461
Area: 3.201 Acre
C: 0.315
Area: 9.423 Acre
C: 0.285
Area: 9.423 Acre
C: 0.285
Area: 0.046 Acre
C: 0.535
Area: 0.195 Acre
C: 0.848
Area: 215.645 Acre
C: 0.384
Area: 215.645 Acre
C: 0.384
NOT TO SCALE
GRASS CHANNEL SECTION #17
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 0.13 CFS --0.34 FPS
10 YR STORM EVENT: 0.18 CFS 0.11' --
CHANNEL SLOPE 2.50%
NOT TO SCALE
GRASS CHANNEL SECTION #21
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 0.41 CFS --0.57 FPS
10 YR STORM EVENT: 0.56 CFS 0.22' --
CHANNEL SLOPE 2.00%
NOT TO SCALE
GRASS CHANNEL SECTION #25
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 0.46 CFS -- 1.91 FPS
10 YR STORM EVENT: 0.64 CFS 0.10' --
CHANNEL SLOPE 12.12%
NOT TO SCALE
GRASS CHANNEL SECTION #18
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 0.67 CFS --0.99 FPS
10 YR STORM EVENT: 0.92 CFS 0.18' --
CHANNEL SLOPE 5.00%
NOT TO SCALE
GRASS CHANNEL SECTION #22
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 0.18 CFS --0.38 FPS
10 YR STORM EVENT: 0.26 CFS 0.12' --
CHANNEL SLOPE 3.00%
NOT TO SCALE
GRASS CHANNEL SECTION #26
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 0.77 CFS -- 1.17 FPS
10 YR STORM EVENT: 1.07 CFS 0.28' --
CHANNEL SLOPE 3.00%
NOT TO SCALE
GRASS CHANNEL SECTION #19
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 1.18 CFS -- 1.15 FPS
10 YR STORM EVENT: 1.63 CFS 0.35' --
CHANNEL SLOPE 2.50%
NOT TO SCALE
GRASS CHANNEL SECTION #23
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 0.45 CFS --2.33 FPS
10 YR STORM EVENT: 0.63 CFS 0.10' --
CHANNEL SLOPE 18.60%
NOT TO SCALE
GRASS CHANNEL SECTION #27
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 0.77 CFS -- 1.95 FPS
10 YR STORM EVENT: 1.07 CFS 0.19' --
CHANNEL SLOPE 8.00%
NOT TO SCALE
GRASS CHANNEL SECTION #20
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 0.52 CFS --0.86 FPS
10 YR STORM EVENT: 0.72 CFS 0.25' --
CHANNEL SLOPE 2.50%
NOT TO SCALE
GRASS CHANNEL SECTION #24
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 1.04 CFS --0.78 FPS
10 YR STORM EVENT: 1.43 CFS 0.39' --
CHANNEL SLOPE 1.50%
NOT TO SCALE
GRASS CHANNEL SECTION #28
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 103.90 CFS --7.14 FPS
10 YR STORM EVENT: 143.04CFS 0.73' --
CHANNEL SLOPE 8.00%
30:1 1.
1
'
12'4'
1'5:1
2'
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
2'
4:1
4'12'
25:11.
8
'
1'
5:1 4:1
2'5'4'
1.
6
'
1'
4:1 5:1
2'4'5'
1.
5
'
1'
12'12'2'
1'
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
4:1
2'4'8.7'
7:11'
1.
5
'
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
3:1
2'3'3'
3:1
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
1.
8
'
1'
4:1
2'4'7'
7:11'
1.
5
'
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
3:1
2'4.3'3'
3:1
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
0.
7
'
1'
4:1
2'4'2.6'
3:1
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
2'
1'
2:1
GRAVEL SHOULDER
4'
GRASS
SHOULDER
3:1
2'3'5'
5:1
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
1.
5
'
1'
8:15:1
10'
5'8'
1.
5
'
1'
VDOT CLASS AI RIPRAP
NOT TO SCALE
CHANNEL SECTION ES-1
PEAK FLOW DEPTH VELOCITY
2 YR STORM EVENT: 103.9 CFS --4.30 FPS
10 YR STORM EVENT: 143.04 CFS 2.35' --
CHANNEL SLOPE 0.43%
3:13:1
10'
2.
3
5
'
9'9'
TRAPEZOID GRASS SWALE
WITH NA GREEN SC150
LINING OR APPROVED
EQUAL
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
DI
T
C
H
C
R
O
S
S
S
E
C
T
I
O
N
S
A
N
D
C
O
M
P
U
T
A
T
I
O
N
S
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
Rev. No. Date
04 09/17/2019
N/A
44
06/28/2019
TTC
19-09
59
2760GC
x-section 28
CF (weighted): 0.331
Total Area: 104.951 Acre
Area: 104.951 Acre
C: 0.331
Area: 0.062 Acre
C: 0.474
Area: 0.433 Acre
C: 0.330
Area: 0.584 Acre
C: 0.434
Area: 0.186 Acre
C: 0.584
Area: 0.213 Acre
C: 0.413
Area: 0.097 Acre
C: 0.393
Area: 0.117 Acre
C: 0.803
Area: 0.299 Acre
C: 0.737
Area: 104.951 Acre
C: 0.331
Area: 0.339 Acre
C: 0.484
Area: 0.127 Acre
C: 0.754
Area: 0.339 Acre
C: 0.484
FULL PROFILE WATERLINE "A"
-0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00
615
620
625
630
610
615
620
625
630
0+
2
0
.
4
1
=
1
1
.
2
5
°
B
E
N
D
0+
4
4
.
7
3
=
4
5
°
B
E
N
D
0+
7
4
.
4
1
=
1
2
"
x
6
"
T
E
E
1-
6
"
G
.
V
.
1+
9
9
.
4
1
=
1
2
"
X
8
"
T
E
E
L
A
T
1-
1
2
"
x
6
"
R
E
D
U
C
E
R
,
1
-
8
"
G
.
V
.
,
1
-
6
"
G
.
V
.
2+
1
7
.
9
1
=
F
H
A
S
S
E
M
B
L
Y
12" W/L DIP CL 52
EX. GRADE
@ PIPE C/L
PROP.
GRADE @
PIPE C/L
4'
MIN.
RESTRAINT JOINTS (TYP.)
COMPACT FILL TO
95% MAXIMUM
DRY DENSITY PER
ASTM D698
FULL PROFILE WATERLINE "B"
0+
0
0
=
1
2
"
T
E
E
W
/
L
A
3-
1
2
"
G
.
V
.
18"
MIN.
-0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00
605
610
615
620
625
630
600
605
610
615
620
625
630
600
-1+00
2+
2
2
.
5
8
=
1
2
"
T
E
E
W
/
L
"
B
"
3-
1
2
"
G
.
V
.
8+
1
3
.
2
5
=
1
2
"
T
E
E
W
/
L
"
D
"
3-
1
2
"
G
.
V
.
13
+
0
3
.
3
9
=
1
2
"
C
R
O
S
S
W/
L
"
E
"
4-
1
2
"
G
.
V
.
9+
7
8
.
8
9
=
1
2
"
x
6
"
T
E
E
1-
6
"
G
.
V
.
2+
1
2
.
5
8
=
4
5
°
B
E
N
D
RESTRAINT JOINTS (TYP.)
12" W/L DIP CL
5
2
12" W/L DIP CL 52
12
"
W
/
L
D
I
P
C
L
5
2
EX. GRADE
@ PIPE C/L
EX. GRADE
@ PIPE C/L
PROP.
GRADE @
PIPE C/L
PROP.
GRADE @
PIPE C/L
PROP.
GRADE @
PIPE C/L
CONNECT
TO EX
WATER
LINE.
CONTRACTOR
TO FIELD
VERIFY
ASBUILT
CONDITIONS
OF WATER
LINE
PRIOR TO
START OF
CONSTRUCTION.
0-
3
7
.
7
6
=
E
X
1
2
"
C
R
O
S
S
EX
2
-
1
2
"
G
.
V
.
0-
2
2
.
2
2
=
E
X
1
2
"
x
6
"
T
E
E
EX
1
-
6
"
G
.
V
.
0-
1
9
.
2
2
=
E
X
1
2
"
G
.
V
.
4'
MIN.
4'
MIN.
COMPACT FILL TO 95%
MAXIMUM DRY DENSITY
PER ASTM D698
STUB TO BE TERMINATED
WITH MJ CAP AND FLUSHING
ASSEMBLY AS REQUIRED BY
FREDERICK WATER
15
"
S
T
M
.
XI
N
G
18"
MIN.
36
"
S
T
M
.
XI
N
G
COMPACT FILL TO 95%
MAXIMUM DRY DENSITY
PER ASTM D698
1.
5
"
S
A
N
I
T
A
R
Y
X
-
I
N
G
W/
6
"
S
C
H
8
0
S
L
E
E
V
E
18"
MIN.
1.
5
"
S
A
N
I
T
A
R
Y
X
I
N
G
W/
6
"
S
C
H
8
0
S
L
E
E
V
E
18"
MIN.
0+
0
0
=
A
P
P
R
O
X
L
O
C
A
T
I
O
N
E
X
W
/
L
4'
MIN.
RESTRAINT JOINTS (TYP.)
5+
3
.
7
4
=
A
I
R
R
E
L
E
A
S
E
/
V
A
C
U
U
M
V
A
L
V
E
-0+50 0+00 0+50 1+00 1+50 2+00
620
625
615
610
620
625
615
610
EX. GRADE
@ PIPE C/L
PROP.
GRADE @
PIPE C/L
1+
1
6
.
6
7
=
F
H
A
S
S
E
M
B
L
Y
605 6051+
0
3
.
6
8
=
1
-
8
"
x
6
"
R
E
D
U
C
E
R
1+
1
1
.
6
0
=
1
-
6
"
G
.
V
.
4'
MIN.
FULL PROFILE WATERLINE "C"
0+
0
0
=
1
-
8
"
X
1
2
"
T
E
E
W
/
L
"
D
"
1-
8
"
G
.
V
.
610
6"
S
A
N
X
I
N
G
30" STM.
XING
8" W/L DIP
CL 52
WA
T
E
R
L
I
N
E
P
R
O
F
I
L
E
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
Rev. No. Date
01 07/22/2019
45
06/28/2019
TTC
19-09
59
2760GC
V: 1" = 5'
H: 1" = 50'
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
NOTE:
1. ALL RESTRAINT JOINTS 20' MINIMUM INTO ORIGINAL GROUND
-0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00
615
620
625
630
635
640
610
615
620
625
630
635
640
FULL PROFILE WATERLINE "D"
1+
8
1
.
5
9
=
1
2
"
x
6
"
T
E
E
2-
6
"
G
.
V
.
5+
5
9
.
5
9
=
1
2
"
x
6
"
T
E
E
2-
6
"
G
.
V
.
6+
5
1
=
4
5
°
B
E
N
D
10
+
4
8
.
2
8
=
1
2
"
T
E
E
W
/
L
"
E
"
3-
1
2
"
G
.
V
.
12" W/L DIP CL 52
12" W/L DIP CL 52
12" W/L DIP CL 52
COMPACT FILL TO
95% MAXIMUM
DRY DENSITY PER
ASTM D698
EX. GRADE
@ PIPE C/L
PROP.
GRADE @
PIPE C/L
4'
MIN.
EX. GRADE
@ PIPE C/L
PROP.
GRADE @
PIPE C/L
4'
MIN.
EX. GRADE
@ PIPE C/L
PROP.
GRADE @
PIPE C/L
4'
MIN.
0+
0
0
=
1
2
"
T
E
E
W
/
L
A
3-
1
2
"
G
.
V
.
-0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50
605
610
615
620
625
630
635
600
605
610
615
620
625
630
635
FULL PROFILE WATERLINE "E"
COMPACT FILL TO 95%
MAXIMUM DRY DENSITY
PER ASTM D698
0+
0
0
=
1
2
"
T
E
E
W
/
L
"
D
"
3-
1
2
"
G
.
V
.
6+
7
1
.
3
0
=
1
2
"
T
E
E
L
A
T
1-
1
2
"
G
.
V
.
9+
0
4
.
8
=
1
2
"
C
R
O
S
S
W
/
L
"
A
"
4-
1
2
"
G
.
V
.
7+
3
7
.
9
8
=
1
2
"
x
6
"
T
E
E
2-
6
"
G
.
V
.
6+
5
1
.
8
5
=
1
2
"
x
6
"
T
E
E
2-
6
"
G
.
V
.
4+
1
1
.
3
0
=
1
2
"
x
6
"
T
E
E
2-
6
"
G
.
V
.
0+
5
0
=
1
2
"
x
6
"
T
E
E
2-
6
"
G
.
V
.
EX. GRADE
@ PIPE C/L
PROP.
GRADE @
PIPE C/L
4'
MIN.
EX. GRADE
@ PIPE C/L
PROP.
GRADE @
PIPE C/L
4'
MIN.
RESTRAINT JOINTS (TYP.)
18"
MIN.
30
"
S
T
M
.
XI
N
G
24
"
S
T
M
.
XI
N
G
18"
MIN.
STUB TO BE TERMINATED
WITH MJ CAP AND FLUSHING
ASSEMBLY AS REQUIRED BY
FREDERICK WATER
STUB TO BE TERMINATED
WITH MJ CAP AND FLUSHING
ASSEMBLY AS REQUIRED BY
FREDERICK WATER
RESTRAINT JOINTS (TYP.)
610
600
1.
5
"
S
A
N
I
T
A
R
Y
X
-
I
N
G
W/
6
"
S
C
H
8
0
S
L
E
E
V
E
2+
8
0
.
1
1
=
1
2
X
8
"
T
E
E
W
/
L
"
C
"
1-
8
"
G
.
V
.
24
"
S
T
M
.
XI
N
G
18"
MIN.
12" W/L DIP CL 52
12" W/L DIP CL 52
12" W/L DIP CL 52
WA
T
E
R
L
I
N
E
P
R
O
F
I
L
E
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
Rev. No. Date
01 07/22/2019
46
06/28/2019
TTC
19-09
59
2760GC
V: 1" = 5'
H: 1" = 50'
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
NOTE:
1. ALL RESTRAINT JOINTS 20' MINIMUM INTO ORIGINAL GROUND
VD
O
T
-
S
I
T
E
D
E
T
A
I
L
S
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
04 09/17/2019
N/A
47
06/28/2019
TTC
19-09
59
2760GC
8' MIN.
18
'
O
R
2
0
'
STRIPED AREA
HANDICAPPED
SYMBOLS
FC
EP
4.0' MIN.
7.0' MAX.
4" STEEL PIPE FILLED WITH CONCRETE
DISPLAY CONDITIONS
24"
6"6"
9"
RESERVED
PARKING
12"
2'
SIGN (SEE DETAIL)
HANDICAPPED PARKING
N.T.S.
04/15
VER 1
NOTE:
RAMP FOR HANDICAPPED MUST
BE LOCATED AT SAME POINT
ADJACENT TO THE STRIPED
AISLE.
LIGHT COLORED
REFLECTIVE
BACKGROUND
MAT'L.
DARK COLORED
2" LETTERS & 3/8"
BORDER
INTERNATIONAL SYMBOL
OF ACCESSIBILITY
UNLAWFUL
PARKING IN THIS
SPACE IS SUBJECT
TO A FINE OF
$50.00 TO $100.00
LIGHT COLORED 1" LETTERS
DARK COLORED REFLECTIVE
BACKGROUND MATERIAL
SIGN SHALL BE LOCATED
SUCH THAT IT WILL NOT
BE OBSCURED BY
VEHICLE PARKED IN
SPACE.
8' VAN ACCESSIBLE SPACE
5' FOR REGULAR SPACE
2" LOCALIZED
DEPRESSION
MIN. SLOPE 4%
2. EXPANSION JOINT FILLER SHALL BE
1/2" BITUMINOUS TYPE PREFORMED
EXPANSION JOINT FILLER, ASTM D-1751
1. UNLESS OTHERWISE NOTED,
CONCRETE SHALL BE CLASS A3
NOTES:
PROVIDE EROSION
PROTECTION PER PLAN
CONCRETE SCUPPER
N.T.S.
3'
MOUND TOP OF CONCRETE FILL
6" DIA. SCHEDULE 40
STEEL PIPE FILLED WITH
CONCRETE AND
PAINTED YELLOW
18' DIA. CONCRETE
ENCASEMENT
BOLLARD DETAIL
N.T.S.
10/28/14
VER 1
3'
7'
6"
4'
PLAN VIEW
9"
12
"
2'
6"
6'
10
'
-
0
"
SL
O
P
E
1
%
M
I
N
.
DUMPSTER
CONCRETE PAD
10'-0"
BOARD ON BOARD ENCLOSURE
2. FINISHED SIDE OF FENCE SHALL FACE
ADJOINING PROPERTY, IF APPLICABLE.
1. PRESERVATIVE STAIN ON ALL WOOD.
COLOR TO MATCH THAT OF BLDG.
NOTES:
3.5"
1.25"
3.5"
1
3
/
4
"
4"X4"X8' POSTS
2"X4"X4' BEAMS, TOE NAIL TO POST
COMPACTED GRAVEL
4'-0"
1"X4"X4'-8" SLATS, 2-FINISH NAIL AT
TOP AND BOTTOM
6"
3"
3'
-
0
"
6'
-
0
"
4"
8"
5'
-
8
"
8"
HOLE FOR GATE LATCH
(TYP)
DUMPSTER ENCLOSURE DETAIL
NOT TO SCALE
1/2"x 6" PRESSURE
CCA TREATED LUMBER
FENCING (NAIL TO STUDS)
4"x4"x6'-9" PRESSURE
CCA TREATED LUMBER
STUD (TYPICAL)
COMPACT SUBGRADE TO 95%
MAX. DENSITY AT THE
OPTIMUM MOISTURE CONTENT
±20% PER AASHTO T-99
6" VDOT CL. A-3 REINF. CONC.
W/6x6-W 1.4x1.4 WWF ON
6" BANK RUN GRAVEL (21 OR
21A TYPE 1 MAT.)
4'-0" LONG
#4 BAR
W/90° BEND
@ CENTER
6x6-W 1.4x1.4
WWF-CENTERED
DUMPSTER FENCE DETAIL
NOT TO SCALEEL.=626.70
EL.=VARIES
1'
DUMPSTER PAD/AT GRADE ACCESS RAMP
RETAINING WALL SECTION VIEW
NTS
AT GRADE ACCESS
RAMP AREA
LOADING DOCK
AREA
WALL & FOOTING
DESIGN BY OTHERS
BOLLARDS TO BE LOCATED
ON EITHER SIDE OF
DUMPSTER PAD RETAINING
WALL. SEE ARCH. PLANS
FOR DETAILS
HAND RAIL (TYP.)
EL.=VARIES
2% SLOPE
5.5'x5.5' CONCRETE PAD
(SIDEWALK DETAIL)
DOOR PAD GRADING DETAIL
N.T.S.
FFE=
FACE OF BUILDING,
ACCESS DOOR
SW=
GND=
CONCRETE SIDEWALK
N.T.S.
11/11/15
VER 1
-2%
4" 4000 PSI VDOT A3 CONCRETE
4" SUBBASE (21-A STONE)
WIDTH VARIES
SEE SITE PLAN
COMPACTED
SUBGRADE
(COMPACTED TO 95%
DENSITY AT OPTIMUM
MOISTURE CONTENT
VDOT VTM-1 METHOD)
6x6 WWMW2.9/2.9
CG-2T - 12" TRUCK CURB
N.T.S.
10/29/14
VER 1
6"2"R
12"
8"
MATCH
ADJ. CONC.
DEPTH
CONCRETE
PAVEMENT
NOTES:
1. CURB SHALL MEET CURRENT SPECIFICATIONS OF VDOT STANDARD CG-6
2. LONGITUDINAL SLOPE OF GUTTER SHALL MATCH SLOPE OF PAVEMENT
3. CONCRETE TO BE CLASS A3 IF CAST IN PLACE, 4000 PSI IF PRECAST
#5 x 12" BARS @ 12 C-C
CG-6T - 12" TRUCK CURB & GUTTER
N.T.S.
6"2"R
12"
8"
MATCH
ADJ. CONC.
DEPTH
CONCRETE
GUTTER
NOTES:
1. CURB SHALL MEET CURRENT SPECIFICATIONS OF VDOT STANDARD CG-6
2. LONGITUDINAL SLOPE OF GUTTER SHALL MATCH SLOPE OF PAVEMENT
3. CONCRETE TO BE CLASS A3 IF CAST IN PLACE, 4000 PSI IF PRECAST
2'-0"
1":1'
CG-6TR - 12" REV. TRUCK CURB & GUTTER
N.T.S.
6"2"R
12"
8"
MATCH
ADJ. CONC.
DEPTH
CONCRETE
GUTTER
NOTES:
1. CURB SHALL MEET CURRENT SPECIFICATIONS OF VDOT STANDARD CG-6
2. LONGITUDINAL SLOPE OF GUTTER SHALL MATCH SLOPE OF PAVEMENT
3. CONCRETE TO BE CLASS A3 IF CAST IN PLACE, 4000 PSI IF PRECAST
2'-0"
1":1'
WHEEL STOP
CG-6TF - 12" FLAT TRUCK CURB & GUTTER
N.T.S.
6"2"R
12"
8"
MATCH
ADJ. CONC.
DEPTH
CONCRETE
GUTTER
NOTES:
1. CURB SHALL MEET CURRENT SPECIFICATIONS OF VDOT STANDARD CG-6
2. LONGITUDINAL SLOPE OF GUTTER SHALL MATCH SLOPE OF PAVEMENT
3. CONCRETE TO BE CLASS A3 IF CAST IN PLACE, 4000 PSI IF PRECAST
2'-0"
0% SLOPE
ASPHALT TRAIL
N.T.S.
11/11/15
VER 1
-2%
4" SUBBASE
(21-A STONE)
WIDTH VARIES
SEE SITE PLAN
COMPACTED SUBGRADE (COMPACTED TO 95%
DENSITY AT OPTIMUM MOISTURE CONTENT
VDOT VTM-1 METHOD)
2'
2" SM9.5A
SURFACE COARSE
2'
SI
T
E
D
E
T
A
I
L
S
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
N/A
48
06/28/2019
TTC
19-09
59
2760GC
NOTES:
1. TRACTOR TRAILER DOLLY PADS ARE SHOWN AT 7' BACK FROM THE FRONT OF THE SPACE AND WITH A
12' CONCRETE WIDTH. CONTRACTOR SHALL CONFIRM LOCATION WITH THE OWNER/DEVELOPER PRIOR
TO CONSTRUCTION TO ENSURE LOCATION IS ACCEPTABLE.
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
FR
E
D
E
R
I
C
K
W
A
T
E
R
D
E
T
A
I
L
S
Rev. No. Date
01 07/22/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
N/A
49
06/28/2019
TTC
19-09
59
2760GC
L = restrained length of pipe (PVC or DIP)
HORIZONTAL BEND
45°, 22 1/2°, 11 1/4°
D 6" 8" 12" 16" 18" 20" 24"
L (ft) 20 20 20 20 20 20 20
L
TEE, CROSS, WYE
any joint that falls within the specified length of
each branch of the fitting shall be restrained.
In addition to restraining each joint of the fitting,
D = pipe diameter
L
LL
L
-2-
TEE, CROSS, WYE AND HORIZONTAL BEND
RESTRAINED JOINTS FOR
D 6" 8" 12" 16" 18" 20" 24"
L (ft) 60 60 100 120 120 140 160
DD
D
L = restrained length of pipe (PVC or DIP)
D = pipe diameter
FEB 09
Both joints of the fitting shall be restrained. In addition, all joints within
the specified length on the large side of the reducer shall be restrained.
REDUCER
L
L (ft) 60 60 100 120 120 140 160
D 6" 8" 12" 16" 18" 20" 24"
L
falls within the specified length shall be restrained.
In addition to restraining the connection, any joint that
VALVE, DEAD END
L
8" 12" 16" 18" 20" 24"
8" -- 60 80 100 120 140
D1
12" -- -- 60 80 100 120
16" -- -- -- 40 60 100
18" -- -- -- -- 40 80
20" -- -- -- -- -- 60
-3-
GATE VALVE AND DEAD END
RESTRAINED JOINTS FOR REDUCER,
6" 40 60 100 120 120 140
D2D1
L
D
L = restrained length of
D = pipe diameter
pipe (PVC or DIP)
L (ft)
D2
L = restrained length of
D = pipe diameter
pipe (PVC or DIP)
FEB 09
L
u
L
d
Lu = up bend restrained lengthof pipe (PVC or DIP)
up bend
depth
depth 4 ft. min.
down bend Ld = down bend restrained length of pipe (PVC or DIP)
finished grade
Lu
Ld
-4-
VERTICAL OFFSET
RESTRAINED JOINTS FOR
45° Ld (ft) 20 40 60 80
Lu (ft) 20 20 20 20
Each side of any vertical offset
bend shall be restrained. In
addition, any joint that falls within
the specified length on each side
of the fitting shall be restrained.
D 6" 8" & 12" 16", 18" & 20" 24"
22 1/2° Ld (ft) 20 20 40 40
Lu (ft) 20 20 20 20
D 6" 8" & 12" 16", 18" & 20" 24"
11 1/4° Ld (ft) 20 20 20 20
Lu (ft) 20 20 20 20
D 6" 8" & 12" 16", 18" & 20" 24"
D
D = pipe diameter
FEB 09
48" min.
6" stone
valve restrained to main
6", 8" and 12"
16", 18", 20" and 24"
screw type adjustable
valve box
8"x 8"x 16"
solid block
60" min.
over-excavation
18" to 24"
concrete pad 18" dia. x 6" deep finished grade
concrete pad 18" dia. x 6" deep finished grade
Water Forced Sewer
24" min.
screw type adjustable valve box
Note: valve shall
be spur gear
type
6" stone
8"x 8"x 16"
solid block
valve
restrained
to main
screw type
adjustable
valve box
concrete pad 18"
dia. x 6" deep
8"x 8"x 16" solid block
for 12" valve
Note: valve shall
be bevel gear
type
GATE VALVE
stone
joint
restraintsstone
valve restrained
to main
48" min.
6" stone
location marker
-5- APR 09
valve box
adaptor
valve box
adaptor
valve box
adaptor
6"
exterior of all sections to
have waterproof coating
3/4" x 2" butyl
joint sealant
24" min. in undeveloped areas
square skid pad 6"
thick around
manhole frame in
developed areas
finished
grade
finished
grade
3/4" concrete anchor
bolts (4 each)
STANDARD MANHOLE
adjustment rings
(11" max.)
steel reinforced
polypropylene steps
24" min.
clear opening
6. There shall be a 0.20 foot drop in elevation through the manhole.
3/4 dia.
6" stone
1'-6"
35" max.
12" or 16" (typ.)
6" stone
4'-0"
variable
3'-0" min.
4'-0" max.
8"
1. Manhole sections shall have an external coating of approved polymer film water proofing prior to installation.
2. If adjustment elevation exceeds two inches use concrete adjustment rings with a exterior coating of
water proofing.
3. Final slope adjustment of manhole frame shall be by shims and non-shrink grout.
4. Skid pad to be placed around manholes located in shoulders of roads.
5. Flat top shall be used if height from invert out to rim is four feet or less. Frame to be 4" in height.
NOTES :
5"pipe to manhole
connection to be
by flexible sleeve
top of bench to be
same elevation as top
of pipe
1" nominal size butyl
joint sealant to be
applied on lower
ledge of joint
top of manhole at grade in pavement areas
unless otherwise directed (top shall be set 24"
min. above grade in undeveloped areas)
invert channel to provide a
smooth transition in to out,
for all connections
precast invert or
grout bottom to
form channel
joint gasket shall be
either o-ring or profile
concrete ASTMC-150
4000 psi
2'-0" max.
-15- FEB 09
18"
3' minimum
PL
2'
treated 2"x 4" with
top 6" painted green
4" pipe at 2.00%
minimum grade
36" min.
cover
property
line
solvent weld cap8" x 4" gasketed bell wye
spigot by gasketed bell 45° bend
location marker
5'
stone
grade
finished
45°
GRAVITY SEWER LATERAL
FOR MAIN WITH COVER 15 FT OR LESS
gasketed pipe and fittings
All pipe and fittings shall be SDR 35/26 .
-22- FEB 09
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
VD
O
T
D
E
T
A
I
L
S
Rev. No. Date
04 09/17/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
N/A
50
06/28/2019
TTC
19-09
59
2760GC
*MODIFY FOR ELLIPTICAL PIPES
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
VD
O
T
D
E
T
A
I
L
S
Rev. No. Date
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
N/A
51
06/28/2019
TTC
19-09
59
2760GC
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
63
0
630
630
620
6
2
0
6
1
0
6
2
0
620
6
3
2
62
8
6
3
0
W W W W W W
W
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
F
M
W W
W W W W W W W W W W
FM
W
W
W
W
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
W
W
W
W
W
W
W
W
W
W
W
W
W
ON
Y
X
D
R
I
V
E
(PR
I
V
A
T
E
A
C
C
E
S
S
)
ON
Y
X
D
R
I
V
E
(PR
I
V
A
T
E
A
C
C
E
S
S
)
W
ARV
3 Pa
3 Pa
1 Pa
2 Pa
1 Pa
1 As
1 As
1 As
3 Cg
1 Zs
1 As
2 Zs
1 As
2 Zs
1 As
2 Zs
1 As
2 Zs
1 As
2 Zs
1 As
3 Cg
3 Cg
3 As
1 Zs 1 Zs
1 Qc
2 Qc
3 Qc
9 As
1 As 2 Zs
1 As
5 Te
29 Te
6 Te
4 Te
1 Qc
3 Pa
3 Pa
1 Zs
1 As
1 Zs
1 Qc 3 Cg
2 Qc
3 Cg
3 Qc
1 Cg
3 Pa
2 Qc
6 Pa
3 Cg
2 Qc
BUILDING 2
BUILDING 1
GR
I
D
M
E
R
I
D
I
A
N
VA
N
O
R
T
H
Z
O
N
E
N
A
D
8
3
3 Te
W
X
X
X
X
X X X X X
X
X
X
X
X
X
X
X
FM FM
F
M
W W W W
E
E
S
S
S
NOTES:
1. TREE SIZE SHOWN ON PLAN VIEW IS ILLUSTRATIVE. SIZES ARE AS SHOWN IN PLANT SCHEDULE
2. ALL PLANTING SHALL CONFORM WITH 165-203.01 OF THE FREDERICK COUNTY ZONING ORDINANCE (PLANT
SELECTION, PLANTING PROCEDURE, AND MAINTENANCE).
3. ANY PLANT SUBSTITUTIONS MUST BE APPROVED IN WRITING BY THE FREDERICK COUNTY PLANNING DEPARTMENT.
4. TREES AND SHRUBS SHALL NOT BE PLANTED WITHIN FCSA EASEMENTS
6. ALL SEEDED AND SODDED AREAS OF PROJECT WILL BE OF A DROUGHT TOLERANT MIX PER PENNINGTON SEED COMPANY.
7. NO SLOPE IN EXCESS OF 25% WILL BE SEEDED OR SODDED.
8. BEFORE SODDING, SEEDING AND LANDSCAPING THE CONTRACTOR WILL TILL ALL COMPACTED AREAS AT LEAST 6" IN DEPTH TO
LOOSEN THE COMPACTED SOILS AND ADD AMENDMENTS
9.SEE PLANTING CALCULATIONS, DETAILS AND NOTES PAGE 53 OF 58
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
LA
N
D
S
C
A
P
E
P
L
A
N
Rev. No. Date
03 09/04/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
AS SHOWN
52
06/28/2019
TTC
19-09
59
2760GC
PARKING LOT PLANT SCHEDULE
Scarlet Oak
European Linden
Quercus coccinea
Tilia x europaeaTe
Qc
17
36" ContainerPlPrunus laurocera English Laurel 66
149 Tree Plantings
66 Total Shrubs
PROPOSED TREE PLANTINGS
PROPOSED SHRUB PLANTINGS
23 2" cal, B&B
2" cal, B&B
PHASE 1 BUFFER PLANT SCHEDULE
ABB BOTANIC NAME COMMON NAME QUANTITY SIZE
318 Plantings
CATEGORY "C" BUFFER - PROPOSED PLANTINGS
Cc Cercis canadensis Eastern Redbud 106
6' HeightGreen Columnar JuniperJuniperus chinensis 'Hetzii Columnaris'Jc 106
2" cal, B&B
36" ContainerSvSyringia vulgaris 'Big Blue'Big Blue Lilac 106
Zs
47 2" cal, B&B
Japanese ZelkovaZelkova serrata
As
17 2" cal, B&B
Sugar MapleAcer saccharum
American PlumbPrunus americanaPa 27 2" cal, B&B
SHRUB PLANTING - DETAIL VIEW SCALE: 1" = 20'
SHRUB PLANTING - DETAIL VIEW SCALE: 1" = 20'
SEE PAGE 53
FOR
SWM
FACILITY
PLANTING
PLAN
38Pl
28Pl
SEE PAGE 53 FOR
LANDSCAPE BUFFER 'C'
DETAIL
Cg Crataegus crus-galli var. inermis Thornless Cockspur Hawthorn 18 2" cal, B&B
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
6
1
0
61
0
6
0
0
620
FM
E
E
E
E
GRID M
E
R
I
D
I
A
N
VA NO
R
T
H
Z
O
N
E
N
A
D
8
3
Ep
Pv/Sc
Pp/Va
Pp/Va
Cc
Sv
Sl
Pp/Va
Pp/Va
Pp/Va
Pp/Va Pp/Va
Pv/ScPv/Sc
Pv/Sc
Pv/Sc
25' ACTIVE
75' INACTIVE100'
24' BERM
1. 6' HIGH EARTHEN BERM WITH 3 PLANTS PER 10L.F.
PLANT SHALL BE 1/3 DECIDUOUS, 1/3 EVERGREENS, AND
1/3 SHRUBS.
2. A 6' OPAQUE FENCE MAY BE SUBSTITUTED BY THE
APPLICANT FOR THE EARTHEN BERM.
CATEGORY "C" 100' FULL SCREEN ZONING
DISTRICT BUFFER
not to scale
CATEGORY "C" BUFFER:
PROVIDE A 100' WIDE FULL SCREEN WITH A 75' WIDE INACTIVE PORTION AND 25' WIDE ACTIVE
PORTION.
PHASE 1 OF SITE (1,055' BUFFER)
1,055/10 = 105.5 USE 106 106x3 PLANTS PER 10 LF = 318 TOTAL PLANTS REQUIRED
318 TOTAL PLANTS PROVIDED
INTERIOR PARKING LOT LANDSCAPING (165-27(E)(11)(b): 1 TREE PER 10 SPACES
136 SPACES PROPOSED/10 = 14 TREES REQUIRED, 14 TREES PROVIDED
PERIMETER LANDSCAPING (165-27-(E)(11)(a): 491,161 S.F. IMPERVIOUS AREA (11.28 ac)
1 TREE PER 100,000 SF IMPERVIOUS AREA / 2000 = 50 TREES REQUIRED
1 TREE PER 391,161 SF IMPERVIOUS AREA / 5,000 = 78 TREES REQUIRED
TOTAL PERIMETER TREES REQUIRED = 128, PERIMETER TREES PROVIDED = 135
TOTAL TREES PROVIDED PHASE I: 149 TREES
PARKING LOT HEADLIGHT SCREENING
66 SHRUBS PROVIDED
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
LA
N
D
S
C
A
P
E
P
L
A
N
Rev. No. Date
03 09/04/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
AS SHOWN
53
06/28/2019
TTC
19-09
59
2760GC
SEPARATION BUFFER LANDSCAPE CALCULATIONS
Jc Cc
Sv
NOTES:
1. AT PLANTING PRUNE ONLY BROKEN OR DEAD
BRANCHES PER ANSI 300 STANDARD
2. PLANTING PIT/TRENCH SHALL BE DUG DEEP
ENOUGH TO ALLOW AT LEAST 1/8TH OF ROOT
BALL TO SET ABOVE EXISTING GRADE
3. PLACE PLANT IN ERECT, STABLE &
UNIFORM POSITION IN THE CENTER OF THE
PLANTING PIT/TRENCH. ORIENT BEST FACE OF
PLANT TO BE THE MOST VISIBLE.
4. BACKFILL SOIL MIXTURE: 34 EXISTING SOIL
CLEANED OF DEBRIS (GRAVEL, STICKS, ROCKS,
TRASH) AND MIXED WITH 14 ORGANIC MATERIAL
(COMPOSTED BARK, LEAF MOLD OR OTHER
PLANT DEBRIS PROCESSED TO A POINT OF
DECAY. PEAT MOSS MAY NOT BE USED.)
5. CONTRACTOR SHALL LEGALLY REMOVE
EXCESS SOIL & DEBRIS FROM SITE
6. DO NOT PLACE MULCH IN CONTACT WITH
STEM OF SHRUBS
**ALL PLANTS MUST BE WATERED TWICE: ONCE
AT INSTALLATION & AGAIN WITHIN 48-HOURS
OF INSTALLATION.
BACKFILL SOIL MIXTURE (TYP.)
FINISHED GRADE
PLACE TOP 18 OF ROOT BALL
ABOVE FINISHED GRADE (TYP)
3" LAYER OF MULCH , NO MORE
THAN 1" OVER ROOT BALL
2-3 X'S WIDTH OF
ROOT BALL (TYP)
SHRUB PLANTING DETAIL
NOT TO SCALE
FOR B&B :
REMOVE TWINE, ROPE, WIRE, &
BURLAP FROM TOP 23 OF ROOT
BALL FOR CONTAINER LOOSEN
THE ROOT BALL OF ANY ROOT
BOUND PLANTS
UNDISTURBED
SUBGRADE OR
COMPACTED BACKFILL
SOIL MIXTURE
NOTES:
1. STAKING AND GUYING MAY BE ONLY
IMPLEMENTED WHERE SITE CONDITIONS
REQUIRE THEIR USE. CONDITIONS WHERE
STAKING AND GUYING MAY BE NECESSARY TO
ENSURE STABILITY INCLUDE WINDY
LOCATIONS, STEEP SLOPES, OR WHERE
VANDALISM MAY BE OF CONCERN.
2. STAKES OR GUYS WILL BE INSTALLED USING
CURRENTLY ACCEPTED ARBORICULTURE
PRACTICES. TREES SHALL STAND LEVEL /
UPRIGHT AFTER STAKING.
3. INSTALLATION WILL INCLUDE THE REMOVAL
OF ALL STAKING AND GUYING MATERIAL ONE
YEAR AFTER INSTALLATION. ANY HOLES
REMAINING AFTER REMOVAL OF STAKES
SHALL BE FILLED WITH TOPSOIL.
4. REFER TO DETAILS FOR TREE PLANTING
INFORMATION
DECIDUOUS TREE STAKING
NOT TO SCALE
PLAN VIEW
(2) 2" X 2" X 8' LODGE POLE PINE OR HARDWOOD
STAKES SET OUTSIDE ROOT BALL. STAKE
LOCATION SHALL NOT INTERFERE WITH
PERMANENT BRANCHES.
32" LONG NON-ABRASIVE RUBBER TIES, LOOPED
AROUND THE TREE, THROUGH EACH OTHER,
TWISTED AND SECURED TO THE STAKES IN A
MANNER WHICH PERMITS TREE MOVEMENT AND
SUPPORTS THE TREE IN ADVERSE CONDITIONS
5'
M
I
N
.
LODGE POLE PINE OR
HARDWOOD STAKES
NON-ABRASIVE TREE TIES
PREVAILING WIND
DIRECTION
NOTES:
1. AT PLANTING PRUNE ONLY CROSSING LIMBS,
BROKEN OR DEAD BRANCHES THAT POSE A HAZARD
TO SITE USERS PER ANSI STANDARD A 300. DO NOT
PRUNE INTO OLD WOOD ON EVERGREENS.
2. CONTRACTOR SHALL MAXIMIZE EXCAVATED AREA
FOR TREE PIT WITHOUT ADVERSELY IMPACTING
ADJACENT SITE FEATURES.
3. BACKFILL SOIL MIXTURE: 34 EXISTING SOIL
CLEANED OF DEBRIS (GRAVEL, STICKS, ROCKS,
AND MIXED WITH 14 ORGANIC MATERIAL
(COMPOSTED BARK, LEAF MOLD OR OTHER
PLANT DEBRIS PROCESSED TO A POINT OF
PEAT MOSS MAY NOT BE USED.)
4. CONTRACTOR SHALL LEGALLY REMOVE
EXCESS SOIL & DEBRIS FROM SITE
5. DO NOT PLACE MULCH IN CONTACT WITH
STEM OF TREE. MULCH MUST BE 6" AWAY FROM
TREE TRUNK
6. TRUNK FLARE MUST BE VISIBLE WHEN PLANTED
7. IF TREE STAKING REQUIRED REFER TO TREE
STAKING DETAILS.
**ALL PLANTS MUST BE WATERED TWICE: ONCE
AT INSTALLATION & AGAIN WITHIN 48-HOURS
OF INSTALLATION.
ROUGHEN / LOOSEN SOIL ON
SIDES OF PLANTING HOLE.
BACKFILL SOIL MIXTURE FOR
ENTIRE TREE PIT AREA & ROOT
BALL DEPTH FIRM SOIL IN 8" LIFTS
PRUNE DOMINANT
LEADERS
3" MULCH NO MORE
THAN 1" ON ROOT
BALL & 6" BACK FROM
TREE TRUNK
CENTER TREE IN PIT & SET TOP OF
ROOT BALL 2" ABOVE ADJACENT
GRADE. TRUNK FLARE SHALL BE
VISIBLE AT THE TOP OF THE ROOT
BALL. DO NOT COVER TOP OF
ROOT BALL WITH SOIL.
4" HIGH X 8" WIDE SOIL
BERM BEGINNING AT
PERIPHERY OF
ROOT BALL.
BOTTOM OF ROOT BALL
RESTS ON EXISTING OR
RECOMPACTED SOIL.
MIN. WIDTH OF TREE PIT
2 X'S ROOT BALL DIAMETER
REMOVE TWINE, ROPE,
WIRE, & BURLAP FROM
TOP 23 OF ROOT BALL
PRIOR TO MULCHING TAMP SOIL
FIRMLY AROUND ROOT BALL
WITH FOOT PRESSURE IN 6"
LIFTS SO THAT ROOT BALL DOES
NOT SHIFT.
UNDISTURBED SUBGRADE
ORIGINAL GRADE
FINISHED GRADE
TREE PLANTING DETAIL
NOT TO SCALE
PRIOR TO MULCHING, LIGHTLY
TAMP SOIL AROUND THE ROOT
BALL IN 6" LIFTS TO BRACE SHRUB.
DO NOT OVER COMPACT.
SECTION VIEW
ROOT BALL RESTS ON EXISTING
OR RECOMPACTED SOIL
4" HIGH X 8" WIDE SOIL BERM
BEGINNING AT PERIPHERY OF
ROOT BALL.
GENERAL CONDITIONS - COUNTY CODE COMPLIANT LANDSCAPE PLAN
SCOPE OF WORK
THE LANDSCAPE CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR AND EQUIPMENT TO COMPLETE ALL LANDSCAPE WORK AS SHOWN
ON THE PLANS AND SPECIFICATIONS.
NOTE: IF CONTRACTOR BIDS ACCORDING TO THE PLANT LIST, HE/SHE SHOULD THOROUGHLY CHECK THE PLANT LIST QUANTITIES WITH
THE SYMBOLS DRAWN ON THE PLAN, TO BE SURE THERE ARE NO DISCREPANCIES. IF THERE IS A DISCREPANCY BETWEEN THE DRAWING
AND THE LIST ON THE PLANS, THE DRAWING TAKES PRECEDENCE.
STANDARDS
ALL PLANT MATERIAL WILL CONFORM TO THE CURRENT ISSUE OF THE AMERICAN STANDARD FOR NURSERY STOCK PUBLISHED BY THE
AMERICAN NURSERY & LANDSCAPE ASSOCIATION (ANLA).PLANT MATERIAL MUST BE SELECTED FROM NURSERIES THAT HAVE BEEN
INSPECTED AND CERTIFIED BY STATE PLANT INSPECTORS.COLLECTED MATERIAL MAY BE USED ONLY WHEN APPROVED BY OWNER'S
REPRESENTATIVE. NOMENCLATURE WILL BE IN ACCORDANCE WITH HORTUS III BY L.H. BAILEY.
SUBSTITUTIONS: PRE-BID
IT IS THE LANDSCAPE CONTRACTOR'S RESPONSIBILITY TO MAKE EVERY REASONABLE EFFORT TO FIND THE PLANTS SPECIFIED BY THE
LANDSCAPE ARCHITECT. THE LANDSCAPE CONTRACTOR MAY OFFER SUBSTITUTIONS TO THE LANDSCAPE ARCHITECT FOR HIS/HER
CONSIDERATION. THE LANDSCAPE CONTRACTOR WILL NOTIFY THE LANDSCAPE ARCHITECT IF THERE ARE KNOWN
DISEASES OR INSECT RESISTANT SPECIES THAT CAN BE SUBSTITUTED FOR A SELECTED PEST-PRONE PLANT. THE CONTRACTOR SHALL
SUBMIT A BASE BID AS PER PLAN PLUS PRICE CLARIFICATIONS FOR ALL RECOMMENDED SUBSTITUTIONS.
SUBSTITUTIONS: POST-BID
IT IS THE INTENT TO ELIMINATE POST-BID SUBSTITUTIONS. HOWEVER, IN THE EVENT THAT THE CONTRACT MATERIAL HAS BECOME
UNAVAILABLE, AN APPROPRIATE SUBSTITUTION MUST BE APPROVED BY THE OWNER'S REPRESENTATIVE.
INSPECTION
A. PLANTS MAY BE SUBJECT TO INSPECTION AND APPROVAL BY THE OWNER OR OWNER'S REPRESENTATIVE AT THE PLACE OF
GROWTH OR HOLDING YARD FOR CONFORMITY TO SPECIFICATION REQUIREMENTS AS TO QUALITY, SIZE AND VARIETY.
B. PLANTS DAMAGED IN HANDLING OR TRANSPORTATION CAN BE REJECTED BY THE OWNER OR OWNER'S REPRESENTATIVE.
C. STATE NURSERY INSPECTION CERTIFICATES SHALL BE FURNISHED TO THE LANDSCAPE ARCHITECT UPON REQUEST.
UTILITIES AND UNDERGROUND FEATURES
THE LANDSCAPE CONTRACTOR SHALL NOTIFY UTILITY COMPANIES AND/OR THE GENERAL CONTRACTOR IN ADVANCE OF CONSTRUCTION TO
LOCATE UTILITIES.
TREES AND/OR SHRUBS SHALL NOT BE PLACED WITHIN FCSA EASEMENTS
IF THERE IS A CONFLICT WITH UTILITIES AND THE PLANTING, THE LANDSCAPE ARCHITECT / DESIGNER SHALL BE RESPONSIBLE FOR
RELOCATING PLANTS PRIOR TO THE PLANTING PROCESS. ANY COST DUE TO RELOCATING AFTER PLANTING SHALL BE BORNE BY THE
OWNER. IF PLANTS ARE TO BE INSTALLED IN AREAS THAT SHOW OBVIOUS POOR DRAINAGE, AND THE PLANTS ARE INAPPROPRIATE FOR
THAT CONDITION, THE LANDSCAPE CONTRACTOR SHALL NOTIFY THE LANDSCAPE ARCHITECT AND OWNER. IF THEY DEEM NECESSARY, THE
PLANTS SHALL BE RELOCATED, THE CONTRACT SHALL BE ADJUSTED TO ALLOW FOR DRAINAGE CORRECTION AT A NEGOTIATED COST, OR
THE PLANT SELECTION MODIFIED BY THE LANDSCAPE ARCHITECT / DESIGNER TO ACCOMMODATE THE POOR DRAINAGE.
WARRANTY
THE STANDARD WARRANTY IS FOR ONE (1) YEAR PERIOD, EXCLUDING BULBS, SOD AND ANNUALS, COMMENCING ON THE DATE OF INITIAL
ACCEPTANCE. ALL PLANTS SHALL BE ALIVE AND IN SATISFACTORY GROWTH AT THE END OF THE GUARANTEE PERIOD. ANY MATERIAL THAT
IS 25% DEAD OR MORE SHALL BE CONSIDERED DEAD AND MUST BE REPLACED AT NO CHARGE. A TREE SHALL BE CONSIDERED DEAD WHEN
THE MAIN LEADER HAS DIED BACK, OR 25% OF THE CROWN IS DEAD. REPLACEMENTS SHALL BE MADE DURING THE NEXT PLANTING PERIOD.
REPLACEMENTS SHALL BE OF THE SAME TYPE, SIZE AND QUALITY AS ORIGINAL SPECIES UNLESS OTHERWISE NEGOTIATED.
STANDARDS
A. PLANTS WILL BE IN ACCORDANCE WITH THE CURRENT ANLA'S STANDARDS AND CONFORM IN GENERAL TO
REPRESENTATIVE SPECIES.
B. BALLED AND BURLAPPED (B&B)
1. BALLED AND BURLAPPED PLANTS SHALL BE DUG WITH FIRM ROOT BALLS FREE OF NOXIOUS WEEDS. THERE
SHOULD BE NO EXCESS SOIL ON TOP OF THE ROOTBALL OR AROUND THE TRUNK
2. BALL SIZES SHALL BE IN ACCORDANCE WITH ANLA STANDARDS.
3. CALIPER AND HEIGHT MEASUREMENT: IN SIZE GRADING B&B SINGLE TRUNK TREES, CALIPER SHALL TAKE
PRECEDENCE OVER HEIGHT. CALIPER OF THE TRUNK SHALL BE TAKEN 6" ABOVE GROUND LEVEL (UP TO AND
INCLUDING 4" CALIPER SIZE) AND 12" ABOVE THE GROUND LEVEL FOR LARGER TREES. FOR MULTIPLE-TRUNK TREES,
HEIGHT MEASUREMENT SHALL TAKE PRECEDENCE OVER CALIPER.
C. CONTAINER - GROWN STOCK
1. THE SIZE OF CONTAINER-GROWN SHRUBS IS MEASURED BY HEIGHT AND WIDTH OF THE PLANT. CONTAINER-GROWN
TREES ARE MEASURED BY THE SAME STANDARDS LISTED IN B.3. ABOVE. THE ROOT SYSTEM OF CONTAINER-GROWN
PLANTS SHALL BE WELL DEVELOPED AND WELL DISTRIBUTED THROUGH OUT THE CONTAINER.
2. ALL CONTAINER-GROWN TREES AND SHRUBS THAT HAVE CIRCLING (GIRDLING) AND MATTED ROOTS SHALL BE
TREATED IN THE FOLLOWING MANNER PRIOR TO PLANTING: SEPARATE THE ROOTS BY HAND, UNTANGLING SO
CIRCLING ROOTS WILL NOT DAMAGE FUTURE OF THE PLANT. SEE PLANTING PROCEDURES FOR ALL
CONTAINER-GROWN TREES & SHRUBS IN THIS SECTION.
3. ALL CONTAINER-GROWN PLANTS SHOULD BE GROUPED AND WATERED DAILY UNTIL THEY ARE PLANTED IN THE
LANDSCAPE, THE SOIL SHALL BE KEPT MOIST WITH THE EQUIVALENT OF ONE-INCH OF RAINFALL PER WEEK.
D. PRUNING SHALL BE DONE BEFORE PLANTING OR DURING THE PLANTING OPERATION.
E. ALL PLANT MATERIAL IN TRANSIT SHALL BE COVERED TO KEEP MATERIAL FROM DRYING OUT. THE COVERING SHALL
COMPLY WITH THE STATE AND LOCAL LAWS PERTAINING TO THE TRANSPORT OF MATERIALS.
F. TREES SHALL BE PLACED IN AN UPRIGHT POSITION WITH THE ROOT BALL COVERED BY MULCH AND KEPT MOIST. TREES
AND SHRUBS SHOULD NOT BE LEFT ON SITE UNPLANTED FOR MORE THAN 24-HOURS WITHOUT ADEQUATE WATER TO
INSURE ROOT SURVIVAL.
WETPOND PLANT SCHEDULE
NOTES:
1. ALL PLANTS ARE AVAILABLE AT AMERICAN NATIVE PLANTS (MD) , COLESVILLE NURSERY (VA) &
WAYNESBORO NURSERY (VA)
2. ALL PLANTING SHALL CONFORM WITH 165-203.01 OF THE FREDERICK COUNTY ZONING ORDINANCE (PLANT
SELECTION, PLANTING PROCEDURE, AND MAINTENANCE).3. ANY PLANT SUBSTITUTIONS MUST BE
APPROVED IN WRITING BY THE FREDERICK COUNTY, VA PLANNING DEPARTMENT.
3 DISTURBED AREAS OF WET POND NOT IDENTIFIED AS BEING PLANTED SHALL BE SEEDED.
ALL SEEDED AND SODDED AREAS OF PROJECT WILL BE OF A DROUGHT TOLERANT MIX PER
PENNINGTON SEED COMPANY NO SLOPE IN EXCESS OF 25% WILL BE SEEDED.
PROPOSED EMERGENT, SUBMERGENT & PERIMETER PLANTINGS
192
1,196
Pond WeedPpPotamogeton pectinatus 581
Joe Pye WeedEpEupatorium purpureum 575 1 Gal., 24" O.C.
SwitchgrassPvPanicum virgatum
Broad Leaf Arrow HeadSaggitaria latifoliaSl
4,426 Plantings
1 Gal., 24" O.C.
1 Gal., 24" O.C.
1 Gal., 24" O.C.Softstem BulrushSvScipus validus 105
Wild CeleryVaValisneria americana 581
PLANT WITH Va
1 Gal., 24" O.C.
PLANT WITH Pp
1,196Wool GrassScirpus cyperinusSc
1 Gal., 24" O.C.
PLANT WITH Sc
1 Gal., 24" O.C.
PLANT WITH Pv
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
ONY
X
D
R
I
V
E
(PR
I
V
A
T
E
AC
C
E
S
S
)
A47-2(22.5')
A47-2
(22.5')
A47-2
(22.5')
A47-2
(22.5')
A47-2
(22.5')
A47-2
(22.5')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')
W8W
(20')W8W
(20')W8W
(20')W8W
(20')W8W
(20')
W8W
(20')W8W
(20')W8W
(20')W8W
(20')W8W
(20')W8W
(20')
A4
(23')
A4-2
(23')
A3
(23')
W8W
(20')
W8W
(20')
W8W
(20')
ONYX
D
R
I
V
E
(PRI
V
A
T
E
ACC
E
S
S
)
A4-2
(23')
2.0
2.5
2.1
3.2
4.3
5.8
5.4
2.2
3.0
3.5
4.4
4.8
5.2
5.4
4.7
5.2
2.5
3.1
3.4
3.7
4.0
4.3
4.4
4.5
5.1
5.1
3.8
2.8
2.5
3.7
3.9
3.4
3.4
3.8
4.0
4.1
4.0
3.8
3.5
3.1
0.4
3.6
6.5
6.3
4.4
3.8
4.3
4.5
4.0
3.7
3.5
3.4
2.8
2.0
1.3
0.8
0.5
0.3
4.4
4.1
6.3
6.7
5.1
4.0
4.0
3.7
2.9
2.0
1.2
0.7
0.4
0.2
5.3
4.5
5.9
5.9
3.9
2.1
0.6
0.4
4.2
1.8
1.2
3.1
1.5
3.3
6.1
6.8
3.9
2.3
0.6
1.2
2.2
3.3
3.7
3.0
2.5
3.6
6.6
8
.
6
5.0
0.5
0.8
1.2
1.7
2.0
2.1
2.3
3.2
4.6
5.3
3.9
2.1
1.4
2.1
4.9
0.3
0.5
0.7
0.9
1.2
1.5
1.9
2.5
3.2
3.5
2.9
2.0
1.7
2.8
5.1
7.7
6
.
0
3.0
0.2
0.3
0.5
0.6
0.8
1.2
1.6
2.2
3.0
3.5
2.9
1.9
2.0
2.8
3.7
4.4
4.1
2.9
2.7
4.3
7.9
8.3
0.3
0.5
0.7
1.1
1.5
2.3
3.1
4.9
4.1
2.3
2.8
3.3
3.1
2.9
2.7
2.5
2.7
3.9
5.5
5.5
3.3
1.7
1.6
2.9
1.0
1.5
2.4
4.1
7.1
6.5
4.5
4.9
3.9
3.0
2.3
2.1
2.1
2.3
2.9
3.6
3.5
2.7
1.8
2.1
3.7
6.7
8.0
4.7
2.4
5.3
5.5
7.0
7.2
4.5
2.7
2.0
1.8
1.9
2.1
2.7
3.3
3.3
2.3
1.8
2.4
3.3
4.4
4.8
3.7
2.7
3.3
6.3
9.2
3.3
2.6
1.8
1.7
1.7
2.0
2.8
3.8
4.2
2.9
2.4
3.1
3.2
3.1
3.0
2.7
2.6
3.3
5.0
6.0
4.4
2.2
1.3
1.6
1.6
2.1
3.1
5.6
6.6
4.8
4.8
4.5
3.4
2.8
2.2
2.2
2.3
2.6
3.3
3.6
3.1
2.0
1.6
2.4
4.5
7.9
7.4
3.7
6.4
5.2
7.9
6.5
3.3
2.4
1.9
1.8
1.9
2.3
2.9
3.3
2.8
1.8
1.8
2.6
3.7
4.9
4.9
3.3
2.6
3.9
7.7
8.9
4.7
2.9
2.2
1.7
1.7
1.7
2.3
3.1
4.0
3.4
2.0
2.4
3.0
3.1
3.1
3.0
2.7
2.7
3.9
5.8
6.2
3.6
1.7
1.3
1.5
1.7
2.6
3.6
6.3
5.6
3.5
4.3
3.8
3.0
2.4
2.2
2.2
2.4
2.9
3.6
3.7
2.8
1.7
1.7
3.0
6.1
8.8
5.8
6.4
7.1
6.4
6.7
4.7
2.9
2.1
1.8
1.8
2.0
2.4
3.0
3.0
2.2
1.7
2.1
3.0
4.5
5.4
4.4
2.8
2.8
5.2
9.1
4.2
2.8
1.9
1.7
1.7
1.9
2.5
3.2
3.6
2.5
1.8
2.5
2.9
3.1
3.2
3.0
2.6
3.1
4.9
6.8
5.4
2.5
1.2
1.0
1.6
1.9
2.8
4.3
5.3
4.0
3.2
3.7
3.3
2.8
2.3
2.2
2.3
2.6
3.3
3.9
3.5
2.2
1.3
1.5
2.7
5.9
9.1
5.3
7.7
6.0
6.5
5.8
3.5
2.6
1.9
1.8
1.9
2.1
2.6
3.0
2.7
1.9
1.4
1.9
3.0
4.8
6.0
4.4
1
.
9
0.8
6.4
3.4
2.4
1.7
1.7
1.7
2.0
2.8
3.3
3.1
1.9
1.7
2.3
2.6
3.0
3.2
2.6
1.5
0.7
1.6
1.6
2.2
2.9
4.8
4.8
2.8
3.0
3.4
2.8
2.3
2.0
1.6
1.1
0.6
6.9
7.7
4.9
5.8
4.8
2.9
2.1
1.5
1.1
0.7
6.9
5.4
2.8
1.8
1.2
0.8
0.5
1.0
0.7
0.4
8.1
0.4
15.3
13.9
8.5
4.5
0.9
0.6
18.3
15.5
9.4
5.1
2.8
1.8
1.5
1.5
1.7
1.6
1.3
0.9
0.6
11.0
19.0
15.2
9.2
5.1
2.9
2.1
1.9
2.0
2.3
2.7
2.7
2.6
2.1
1.3
0.8
16.0
18.9
14.1
8.4
4.8
3.0
2.3
2.3
2.8
3.6
4.1
4.3
4.0
3.2
1.9
1.0
0.5
18.8
18.2
12.6
7.5
4.4
2.9
2.5
2.7
3.5
5.1
6.4
8.2
7.0
4.3
19.7
17.0
11.2
6.6
4.0
2.8
2.6
3.0
4.3
7.0
9.5
12.5
12.5
19.5
1
5
.
5
9.8
5.7
3.5
2.6
2.6
3.2
4.6
6.9
11.0
14.9
17.0
18.8
1
3
.
9
8.4
4.9
3.1
2.4
2.4
2.9
4.1
5.9
9.9
10.8
19.3
17.9
12.3
7.3
4.2
2.7
2.1
2.1
2.5
3.3
4.2
6.0
6.3
3.8
19.4
16.6
10.6
6.2
3.6
2.3
1.8
1.8
2.0
2.5
3.3
3.9
4.1
2.9
1.7
13.8
19.1
14.7
9.0
5.1
3.0
2.0
1.5
1.4
1.6
1.9
2.3
2.7
2.7
2.5
2.4
2.7
3.1
2.8
1.4
17.3
1
7
.
7
12.7
7.4
4.2
2.5
1.7
1.3
1.2
1.3
1.4
1.6
1.9
2.2
2.6
3.1
3.9
5.1
5.1
2.6
17.2
15.4
10.2
5.8
3.3
2.0
1.4
1.1
1.0
1.0
1.1
1.3
1.6
2.1
2.7
3.9
5.3
8.6
9.4
6.1
12.6
11.2
7.2
4.2
2.5
1.6
1.1
0.9
0.8
0.8
0.9
1.1
1.5
2.1
2.9
4.2
5.7
9.0
10.3
3.8
6.5
6.7
4.6
2.9
1.8
1.2
0.9
0.7
0.7
0.7
0.8
1.0
1.5
2.2
3.2
4.6
6.2
7.0
5.7
4.2
3.0
2.0
1.3
1.0
0.8
0.7
0.7
0.7
0.8
1.0
1.6
2.3
3.4
4.9
6.5
6.5
1.0
1.1
1.2
1.0
0.8
0.8
1.1
1.6
2.4
3.8
5.3
8.5
8.8
2.2
1.8
1.2
0.9
1.1
1.6
2.3
3.6
5.5
9.4
11.2
1.2
2.4
3.6
4.9
6.2
6.0
4.0
1.7
2.9
1.8
2.9
4.7
9.6
14.0
15.6
1.6
2.8
4.4
7.1
10.3
11.4
9.9
6.6
6.1
1.4
2.2
3.6
5.2
7.2
7.0
6.0
5.4
5.4
6.3
10.2
13.9
15.6
0.6
1.0
1.6
2.4
3.3
4.1
4.4
4.3
4.1
4.4
5.5
7.6
10.2
11.0
9.4
6.2
5.7
5.8
0.5
0.8
1.1
1.6
2.0
2.4
2.7
2.8
2.9
3.3
4.2
5.5
7.0
6.7
5.7
5.1
4.9
5.5
8.9
13.2
15.6
12.8
0.4
0.6
0.8
1.0
1.3
1.5
1.7
1.8
2.0
2.3
2.8
3.3
4.0
4.2
4.0
3.8
4.0
5.0
6.5
9.4
10.7
9.8
6.8
5.8
5.9
0.3
0.4
0.6
0.7
0.9
1.0
1.1
1.2
1.3
1.5
1.8
2.1
2.4
2.6
2.6
2.7
3.0
3.7
4.9
6.5
6.8
6.0
5.4
4.9
5.5
7.8
12.1
1
5
.
4
13.9
0.3
0.4
0.4
0.5
0.6
0.6
0.7
0.7
0.8
0.9
1.0
1.2
1.3
1.5
1.6
1.7
1.8
2.1
2.6
3.1
3.7
4.1
4.1
3.9
3.9
4.7
6.0
8.6
10.4
10.0
7.2
5.7
5.7
6.8
0.4
0.4
0.5
0.5
0.5
0.6
0.6
0.6
0.6
0.7
0.7
0.8
0.9
1.0
1.0
1.1
1.2
1.4
1.7
2.0
2.2
2.5
2.6
2.7
2.9
3.5
4.6
6.0
6.7
6.0
5.4
4.8
5.1
6.6
11.0
1
4
.
5
14.6
10.4
0.5
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.8
0.8
0.9
1.1
1.3
1.4
1.6
1.7
1.8
2.0
2.4
2.9
3.5
4.0
4.0
3.8
3.7
4.3
5.4
7.7
10.0
10.3
8.2
5.8
5.8
6.4
0.7
0.8
0.8
0.8
0.8
0.8
0.7
0.7
0.7
0.7
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.8
0.9
1.0
1.0
1.1
1.2
1.3
1.6
1.9
2.1
2.4
2.5
2.5
2.7
3.2
4.2
5.4
6.8
6.4
5.5
5.1
5.0
5.9
9.9
13.6
1
5
.
0
11.8
1.2
1.3
1.3
1.3
1.2
1.1
1.0
0.9
0.9
0.8
0.8
0.7
0.7
0.7
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.8
0.8
0.9
1.1
1.2
1.4
1.5
1.6
1.7
1.8
2.2
2.8
3.3
3.8
4.1
3.9
3.7
4.1
5.2
7.0
9.5
10.2
8.8
6.2
5.8
6.1
8.7
2.2
2.3
2.2
2.1
1.9
1.7
1.5
1.3
1.2
1.1
1.0
1.0
0.9
0.8
0.8
0.7
0.7
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.8
0.9
0.9
1.0
1.0
1.1
1.2
1.5
1.8
2.1
2.3
2.5
2.6
2.7
3.0
3.9
5.0
6.5
6.4
5.6
5.2
4.9
5.6
8.6
12.6
1
4
.
7
12.1
6.8
4.3
4.5
4.2
3.8
3.3
2.8
2.4
2.0
1.8
1.6
1.5
1.4
1.2
1.1
1.0
0.9
0.9
0.8
0.7
0.7
0.7
0.7
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.8
0.8
1.0
1.2
1.3
1.5
1.6
1.7
1.8
2.1
2.6
3.1
3.6
3.9
3.9
3.7
3.9
4.8
6.2
8.6
9.5
8.1
5.0
3.3
6.8
8
.
5
8.7
8.1
7.1
6.1
5.0
4.1
3.4
2.9
2.5
2.3
2.1
1.9
1.7
1.5
1.3
1.2
1.1
1.0
0.9
0.8
0.8
0.7
0.7
0.7
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.8
0.9
1.0
1.0
1.1
1.2
1.4
1.7
2.0
2.2
2.4
2.5
2.6
2.8
3.5
4.5
5.8
5.8
4.8
3.8
2.5
11.1
14.5
15.1
14.3
12.7
10.9
9.0
7.0
5.6
4.8
4.3
3.9
3.5
3.1
2.7
2.3
2.0
1.7
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.8
0.7
0.7
0.7
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.8
0.8
1.0
1.1
1.3
1.4
1.5
1.6
1.7
1.9
2.3
2.8
3.2
3.4
3.1
2.4
1.7
12.3
17.8
19.2
19.1
18.5
16.8
14.6
1
1
.
5
8.9
7.8
7.6
7.1
6.5
5.7
4
.
8
4.0
3.3
2.7
2.3
2.1
1.9
1.7
1.6
1.4
1.3
1.1
1.0
0.9
0.9
0.8
0.8
0.7
0.7
0.7
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.8
0.9
0.9
1.0
1.0
1.1
1.3
1.5
1.7
1.9
2.0
1.8
1.5
1.2
14.8
18.3
19.4
18.1
15.0
11.1
11.5
12.8
1
2
.
7
11.6
10.1
8.6
7.1
5.7
4.6
3.9
3.4
3.1
2.8
2.5
2.2
1.9
1.7
1.5
1.3
1.2
1.1
1.0
0.9
0.9
0.8
0.7
0.7
0.7
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.8
0.9
1.0
1.1
1.2
1.2
1.1
0.9
11.3
10.1
14.0
17.3
18.3
17.7
16.4
14.5
12.3
9.7
7.6
6.4
5.9
5.5
5.0
4.4
3.7
3.2
2.6
2.2
1.9
1.7
1.6
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.8
0.7
0.7
0.7
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.8
0.7
0.7
0.6
11.9
16.8
19.3
19.8
19.0
17.5
1
4
.
3
10.7
9.8
10.2
10.0
9.1
8
.
0
6.8
5.6
4.6
3.7
3.1
2.7
2.5
2.2
2.0
1.8
1.6
1.4
1.3
1.1
1.0
0.9
0.9
0.8
0.8
0.7
0.7
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.5
0.5
0.4
14.0
16.8
1
5
.
1
11.2
12.6
15.6
16.2
15.2
13.7
1
2
.
0
9.9
7.9
6.2
5.2
4.7
4.3
3.9
3.4
2.9
2.5
2.2
1.9
1.6
1.5
1.3
1.2
1.1
1.0
0.9
0.9
0.8
0.7
0.7
0.6
0.6
0.6
0.5
0.5
0.4
0.4
0.3
0.2
0.2
0.1
0.1
10.8
16.9
19.2
19.4
19.0
17.8
15.8
12.8
9.7
8.3
8.0
7.6
7.0
6.2
5.3
4.4
3.6
3.0
2.5
2.2
2.0
1.8
1.7
1.5
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.7
0.6
0.5
0.4
0.4
0.3
0.2
0.2
0.1
0.1
11.7
16.5
19.0
18.6
16.1
11.8
11.3
13.2
13.4
12.5
1
1
.
1
9.5
7.9
6.4
5.1
4.2
3.7
3.3
3.0
2.7
2.4
2.1
1.8
1.6
1.4
1.2
1.1
1.0
0.9
0.8
0.7
0.5
0.4
0.3
0.3
0.2
0.1
0.1
0.1
10.2
9.4
12.5
16.9
18.6
18.3
17.3
15.6
1
3
.
5
10.8
8.3
6.9
6.3
5.9
5.4
4.8
4.1
3.5
2.9
2.4
2.1
1.8
1.6
1.4
1.3
1.1
0.9
0.7
0.6
0.4
0.3
0.2
0.2
0.1
0.1
14.3
18.3
20.0
19.4
18.4
15.6
11.7
10.1
10.5
10.6
9.8
8.7
7.5
6
.
2
5.1
4.1
3.4
2.9
2.6
2.3
2.0
1.7
1.4
1.1
0.8
0.6
0.4
0.3
0.2
11.0
15.2
1
5
.
5
11.8
11.9
15.5
16.7
16.0
1
4
.
7
12.9
11.0
8.8
6.9
5.6
5.0
4.6
4.1
3.5
2.9
2.3
1.7
1.2
0.8
0.5
0.3
8.0
14.9
18.6
19.5
19.5
18.6
16.9
14.1
10.7
8.8
8.4
8.2
7.6
6.6
5.4
4.1
2.8
1.8
1.1
0.7
0.4
14.0
17.8
1
8
.
8
16.8
12.6
11.0
13.2
14.0
13.4
11.8
9.9
7.4
4.9
2.9
1.6
0.8
0.5
8.3
8.6
10.8
16.2
18.3
18.6
17.8
16.0
12.3
7.7
3.9
1.8
0.9
0.4
10.6
15.8
18.6
18.4
15.3
8.9
3.8
1.6
0.7
8.4
6.0
2.4
1.0
0.4
0.1
W8W
(20')
A4-2
(23')
A4-2
(23')
A4-2
(23')
A4-2
(23')
A4-2
(23')
A4-2
(23')
A4
(23')
A3
(23')
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
02 08/16/2019
1" = 50'
54
06/28/2019
TTC
19-09
59
2760GC
Calculation Summary
Label CalcType Units Avg Max Min
CAR LOT #1 Illuminance Fc 3.54 6.7 0.2
CAR LOT #2 Illuminance Fc 3.23 9.2 0.2
TRUCK LOT #1 Illuminance Fc 5.19 19.7 0.5
TRUCK LOT #2 Illuminance Fc 4.52 20.0 0.1
Luminaire Schedule
Symbol Qty Label Arrangement Total Watts
2 ALED4T150 SINGLE 23 MTG SINGLE 311.6
8 ALED4T150 2 @ 90 23 MTG 2 @ 90 DEGREES 2492.8
2 ALED3T78 SINGLE 22-6 MTG SINGLE 153.6
11 WPLED80 - Cool - RAB02597 SINGLE 922.9
49 WPLED80 WALL 20 MTG SINGLE 4111.1
5 ALED4T78 2@180 SIDESHIELD 22-6 GROUP 770
NOTES:
1. ALL LIGHTS SHALL BE MOUNTED NO HIGHER THAN THE MAXIMUM HEIGHT OF 25' AS MEASURED TO GROUND
PER FREDERICK COUNTY ZONING ORDINANCE 165-201.06.
2. FULL CUTOFF WALLPACKS AND FULL CUTOFF AREA FIXTURES ARE PROPOSED.
TYPICAL 23.0' LIGHT POLE DETAIL
NOT TO SCALE
CONCRETE LIGHT
POLE BASE (DESIGN
BY STRUCTURAL
ENGINEER)
FINISHED GRADE IS
3' BELOW THE TOP
OF THE BASE
23
'
25
'
M
A
X
.
P
O
L
E
H
E
I
G
H
T
(
P
E
R
F
R
E
D
E
R
I
C
K
C
O
U
N
T
Y
C
O
D
E
)
CONCRETE LIGHT
POLE W/ BASE
LIGHT FIXTURE
20
'
3'
TYPICAL 22.5' LIGHT POLE DETAIL
NOT TO SCALE
CONCRETE LIGHT
POLE BASE (DESIGN
BY STRUCTURAL
ENGINEER)
FINISHED GRADE IS
2.5' BELOW THE TOP
OF THE BASE
22
.
5
'
25
'
M
A
X
.
P
O
L
E
H
E
I
G
H
T
(
P
E
R
F
R
E
D
E
R
I
C
K
C
O
U
N
T
Y
C
O
D
E
)
CONCRETE LIGHT
POLE W/ BASE
LIGHT FIXTURE
20
'
2.
5
'
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
Rev. No. Date
N/A
55
06/28/2019
TTC
19-09
59
2760GC
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
TR
A
I
L
M
A
P
Rev. No. Date
03 09/04/2019
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
AS SHOWN
56
06/28/2019
TTC
19-09
59
2760GC
NOT TO SCALE
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
PR
O
F
F
E
R
S
Rev. No. Date
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
N/A
57
06/28/2019
TTC
19-09
59
2760GC
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
PR
O
F
F
E
R
S
Rev. No. Date
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
N/A
58
06/28/2019
TTC
19-09
59
2760GC
S
S
S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W W
W
W
A
R
V
620
624
630 628 626
628 630626624
6
1
8
6
1
6
620
622
624
624
622
620
628
628
6
2
8
630
626
628 626
6
2
4
6
2
8
6
2
662
4
622
622
6
2
2
6
2
4
624
6
2
6
628
6
2
8
630
630
628
626
626
626
6
2
4
6
2
4
628
6
2
6
626628
620
624 622
626
6
2
6
6
2
4
626
604
606
608
610
614616
602603
ONYX DRIVE
(PRIVATE ACCESS)
14.5'
EXISTING BRUSH
OBSTRUCTING SIGHT
LINE TO BE REMOVED
AS NECESSARY (TYP)ESTIMATED CENTER OF
LANE ESTIMATED CENTER OF
LANE
0+60 2+00 3+00 4+00 4+50 5+00 6+00 7+00 8+00 8+46.97
390' INTERSECTION
SIGHT DISTANCE 390' INTERSECTION
SIGHT DISTANCE
390'
EXISTING BRUSH
OBSTRUCTING SIGHT
LINE TO BE REMOVED
AS NECESSARY (TYP)
GRID M
E
R
I
D
I
A
N
VA NOR
T
H
Z
O
N
E
N
A
D
8
3
615
620
625
630
635
615
620
625
630
635
0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00
MILBURN ROAD & PRIVATE DRIVE
℄ P
R
I
V
A
T
E
D
R
I
V
E
EXISTING
GRADE
390' SIGHT LINE
390' SIGHT LINE
3.
5
'
E
Y
E
HE
I
G
H
T
3.
5
'
E
Y
E
HE
I
G
H
T
3.
5
'
E
Y
E
HE
I
G
H
T
15
1
W
i
n
d
y
H
i
l
l
L
a
n
e
Wi
n
c
h
e
s
t
e
r
,
V
i
r
g
i
n
i
a
2
2
6
0
2
Te
l
e
p
h
o
n
e
:
(
5
4
0
)
6
6
2
-
4
1
8
5
Fa
x
:
(
5
4
0
)
7
2
2
-
9
5
2
8
ww
w
.
g
r
e
e
n
w
a
y
e
n
g
.
c
o
m
F
N
D
1
9
7
1
E
N
G
I
N
E
E
R
I
N
G
SHEET OF
DESIGNED BY:
FILE NO.
SCALE:
DATE:
PR
O
U
D
L
Y
S
E
R
V
I
N
G
V
I
R
G
I
N
I
A
&
W
E
S
T
V
I
R
G
I
N
I
A
OF
F
I
C
E
S
I
N
:
W
I
N
C
H
E
S
T
E
R
,
V
A
&
M
A
R
T
I
N
S
B
U
R
G
,
W
V
SP NUMBER: #26-19
SI
G
H
T
D
I
S
T
A
N
C
E
M
I
L
B
U
R
N
R
O
A
D
GR
A
Y
S
T
O
N
E
I
N
D
U
S
T
R
I
A
L
C
E
N
T
E
R
P
H
A
S
E
I
ST
O
N
E
W
A
L
L
M
A
G
I
S
T
E
R
I
A
L
D
I
S
T
R
I
C
T
FR
E
D
E
R
I
C
K
C
O
U
N
T
Y
,
V
I
R
G
I
N
I
A
06/28/2019
TTC
19-09
2760GC
V: 1" = 5'
H: 1" = 50'
PLAN VIEW
1" = 50'
NOTES:
1. INTERSECTION SIGHT DISTANCE DETERMINED FROM TABLE 2-5 FROM
APPENDIX F OF THE VDOT ROAD DESIGN MANUAL ISSUED JANUARY,
2005, REVISED JULY, 2017 UTILIZING THE LEGAL SPEED OF 35 MPH
FOR AN UNPAVED ROAD. THE REQUIRED INTERSECTION SIGHT
DISTANCE IS 390 FT.
Rev. No. Date
06 10/21/2019
59 59