Loading...
HomeMy WebLinkAbout38-19 CommentsREQUEST FOR SIE LAN COMMENTS Frederick County Inspections Department Comment Mail to: rederick County inspections Department Attn: Building Official 107 North Kent Street Winchester, Virginia 22601 loII � L w5gn,", gas ,,Ou, C,,"" ViA Hand deliver to: ff \I( ED Frederick County Inspections Dept.S EP 10 2019 107 North Kent Street, 2nd Floor VrIl Winchester, Virginia 22601 Frederick County Phone: (540) 665-5650 Public Works & Inspections Applicant: It is your responsibility to complete this form as accurately as possible in order to assist the agency with their review, ,; PleasCA49ch,two (2)::conies,of.the Site Pia„ ..1.....a Applicant's Name: Greenway Engineering INc. Telephone: 540-662-4165 Email Address: jtweediecagreenwayeng.corn Mailing Address: 151 Windy Hill Lane Winchester, VA 22602 Name of development and description of the request: NTB - CB Ventures Location of Property: 165 Amoco Lane Winchester, VA 22603 ns ections Department Comments: _( LnY 121 AJ --S -FREDERICK COUNTY INSPECTIONS DEPARTMENT USE ONLY - Date Received/ �j /o122i I q Date Reviewed / Rl / / Review Numb 4 5 (circle one) Revision Required_ N() Date Appro ed � 2 2 11 Cf �aiaatuM _''a 18 Buildings shall comply with The Virginia Uniform Statewide Building Code and Sections 311; S Storage) of the International Building Code/2015. Other Code that applies are the International Mechanical Code for air change, the ICC ANSI A117.1-3-09 Accessible and Usable Buildings and Facilities, 2015 Virginia Energy Code and 2015 International Fire Code. Addition shall comply with height and area as allowed per T506 with the applicable increases. Type of construction shall be maintained unless a separate building is constructed. Building shall comply with IBC/USBC 903.2.9 for sprinkler requirements. Group S-1 fire areas used for the storage of commercial trucks where the fire area exceed 5000 sq ft, as well as, S -I fire areas in excess of 5, 000K sq ft and used for commercial truck repair garage shall be provided with an NFPA 13 sprinkler system Quantity of hazardous material quantities and limitations shall be as required/limited under T307.1(1) to prevent the structure from falling into an H -Hazardous use group Tire storage, per Section 903.2.9.2 limits tire storage to 20,000 cubic square feet in buildings without sprinkler system water oil separator provided outside of the building ANSI parking spaces provided as required per T1106.1. Accessible parking and unloading shall not exceed 2% slope (1:48). Accessible Route shall extend from parking and unloading area to accessible route to main entrance. Van spaces require minimum unloading area 8' with 8' of parking or a minimum of 11' wide parking with 5' of unloading space is required. Accessible route with max 5% slopes shall be provided from parking/unloading to main entrance. Please provide elevation marks on all four side of parking and unloading area. Approach to entrance door requires minimum 60" clear. Building shall comply with 2015 Virginia Energy Code. All systems shall be included in the evaluation of the building performance. All structural plans submitted for permit application shall be sealed by a VA Design Professional. Please note the requirements in Chapter 17 of the VBC for special inspections for this te of structure. (soil, concrete, bolts, etc.) yp 10/22 revised front main entrance as required. Accessible parking provided with max 2% slope. Access aisle across travel lanes shall be marked. S:\Site Plan comments\2015\S-1 Repair Garage; CB Ventures, revised.doc Frederick C arin4, Deparanent ®f Fire and Rescue Office of the Fire Marshal 10-30 Consrsione Drh-e lI hichecrer, I A 22602 (540) 663-6350 Far. (541) 67.9-4-739 Einail: fntog cva.us Pfau Review & Comments Date Received Date Reviewed 9/1012018 10119/2019 Plan/Permit Type Site Plan 09.10-19 Name CB Ventures, LLC Address Amoco LN Winchester VA 22603 Project Name Commercial Development Applicant Narne & Number Greenway Engineering 540-662.4185 RE# Permit Number Emergency Vehicle Access- Ad uate Inadequate NIA Hydrant Location: A*4uate Inadequate NIA Siamese Location- Adequate Inadequate NIA Fire Lanes Required. Y s NG NIA Plan Approval Status Approve Comments Areas hi -lighted In yellow shall be striped in yellow Areas hi -lighted In orange shall have No Parking Fire Lane signs installed Signaturo: Reviewed By.. Kenneth Scott, Jr. Title: �t--- REQUEST FOR SITE PLAN COMMENTS Request for Street Mame Comment Mail to: Frederick County Information Technologies, GIS Division Attn: GIS Manager 107 North Kent Street Winchester, Virginia 22601 Hand deliver to: Frederick County Information Technologies, GIS Division 107 North Kent Street, I" Floor Winchester, Virginia 22601 Phone: (540) 665-5614 Applicant: It is your responsibility to complete this form as accurately as possible in order to assist the agency with their review. Please attach two (2) conies of the Site Plan with this sheet. Applicant's Name: Email Address: Mailing Address: itweedle@greenwayeng.com 151 Windy Hill Lane Winchester, VA 22602 Name of development and description of the request: NTB - CB Ventures Location of Property: 416 Winchester, VA 22603 Telephone: 540-662-4165 -GIS MANAGER USE ONLY' - Date Received `,'Iijolj Review 3 4 5 Date Reviewed I t (circle one) Revision Required__ _ �— Date Approved t 2-11 Signature & Date; ** Please Return Form to Applicant** 17 COUNTY of FREDERICK Department of Public Works $40/665-5643 FAX: 540/678-0682 October 21, 2019 Mr. Jeremy Tweedie Greenway Engineering 151 Windy Hill Lane Winchester, Virginia 22602 RE: Revised Site Plan Comments — CB Ventures -Land Bay 4 Dear Mr. Tweedie: Upon review of the revised site plan dated October 11, 2019, we recommend approval of the subject plan. Joseph W. Johnson, P.E. Civil Engineer JCW/kco cc: Planning and Development file Sincerely, Joe C. Wilder Director of Public Works 107 North Kent Street, Second Floor, Suite 200 w Winchester, Virginia 22601-5000 41, FREDERICK WATER WATER SITE PLA` REVJEV CO.NINIFNT PO Box 1877, Winchester, VA 22604-8377 540.868.1061 voice 315 Tasker Road, Stephens City, VA 226555 q /j 540.868.1 329 fax S/ rf Project C? f V ! V i� V Applicant C—) T� REVIEW STATJS reti iew numbery correct & resubmit approved as noted roved DRAWINGS atlention—m—c . Acei "y / W'G• "iv t number of items to be corrected send me by lo 1. print of sheets L 2. two CDs: each disc shall contain the follo •ing plan sheets a) One CD (containing; all of the above noted sheets) shall be in PDF format. ach sheet shall be in its own file and be in landscape orientation. Each file shall be titled with the project name and appropriate sheet number. b) One CD shall be in D%VG format, (1) in Model Space. (2) in state plane coordinate system NAD 83.(3) compatible with AutoCAD 2006. c) Each of the two CDs shall be labeled with its format and project name, and placed in its own paper CD envelope. EASEMENT Y J A copy of the recorded onsite FW easement(s) is/are required_ Y /0A copy of the recorded offsite FW easement(s) is/are required. The easement document shall contain a plat and both shall be signed by the Frederick Water. o The Frederick Water requires specific lan fguage in its deed of easement. o Visit our website www.frederickwater.com to obtain a copy of the form. o A copy of the recorded deed(s) of easement shall be received before service will be authorized. OTHER Y ; N This project also requires DEQ - Valley Region Office approval. Y /� This project also requires VDH — Lesin_ton Field Off ice approval. Y This project also requires VDH — Lexington Field Office — Project Summary Report. BY DATE FOR DRAWINGS ABOVE, see VDH website for form Y /V This project has a sewer pump station that FW will own. Title to the pump station site shall be granted to the Frederick Water in fee simple absolute. Also, (1) a copy of DEQ's Certificate to Construct, (2) a copy of DEQ's Certificate to Operate, and (3) two copies of the FW approved O & M manual are required. These documents must be received before service will be authorized. (4) Work cannot commence that would connect it) FW facilities or require FW inspections until the contract is returned to qiis office. / Date: " q Earl `a'l'. Wiley — Engecring Assistant