Loading...
HomeMy WebLinkAbout02-19 Site PlanSITE LAKE FREDERICK FAIR F A X P I K E RTE 2 7 7 K: \ P r o j e c t s \ F C S A \ F C S A 1 6 0 5 - L a k e - F r e d e r i c k - E l e v - W a t e r - S t o r a g e \ D E S I G N \ _ P U B L I S H \ S h e e t s \ C S 0 0 0 0 . d w g PL O T T E D : 3/ 2 1 / 2 0 1 9 4 : 3 4 P M , B Y : Da v i d F r a n k PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S :   CS0000 BY NO . DA T E RE V I S I O N S LA K E F R E D E R I C K E L E V A T E D W A T E R T A N K 18 2 0 F A I R F A X P I K E ST E P H E N S C I T Y V A . P. O . B O X 1 8 7 7 WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 FR E D E R I C K W A T E R CO V E R S H E E T FCSA1605 AS NOTED TEAM 2019-01-04 DAF/ERS SHEET APPROVED BY OF1 18 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PREPARED FOR: OWNER/DEVELOPER FREDERICK WATER P.O. BOX 1877 WINCHESTER, VIRGINIA 22601 (540) 868-1061 LAKE FREDERICK ELEVATED WATER TANK     FREDERICK COUNTY, VIRGINIA OPEQUON DISTRICT ORIGINAL SUBMISSION: JANUARY 9, 2019 REVISED SUBMISSION: REVISED FEBRUARY 22, 2019 NO R T H 2/ 2 2 / 2 0 1 9 1 R E V I S E D P E R A G E N C Y C O M M E N T S KL M                                                  PREPARED BY: PENNONI ASSOCIATES INC. 117 East Piccadilly Street Winchester, VA 22601 T 540.667.2139 F 540.665.0493   PERMIT DRAWINGS CS0000 PE N N O N I A S S O C I A T E S I N C . 11 7 E a s t P i c c a d i l l y S t r e e t Wi n c h e s t e r , V A 2 2 6 0 1 T 54 0 . 6 6 7 . 2 1 3 9 F 54 0 . 6 6 5 . 0 4 9 3 LOCATION MAP SCALE: 1" = 3000' SHEET INDEX Sheet No.Title Desc. 1 Cover Sheet   2 Notes and Legends   3 Maintenance Of Traffic   4 Existing Conditions Plan   5 Site Plan   6 Grading Plan   7 Water and Storm Profiles and Miscellaneous Details   8 Storm Water Management Drainage Map   9 Storm Water Management Details   10 Erosion and Sediment Control Plans   11 Erosion and Sediment Control Details and Narrative   12 Erosion and Sediment Control Details   13 Frederick Water Details   14 Site Details and Sight Distance   15 Water Tank Miscellaneous Details   16 Water Tank Miscellaneous Details   17 Water Tank Miscellaneous Details   18 Landscape Plan, Notes, and Details DAVID L. FRANK Lic. No.1061   CALL 1-800-552-7001 CALL BEFORE YOU DIG ALWAYS CALL 811 BEFORE YOU DIG IN VIRGINIA SECTION 56-265.17 REQUIRES THREE WORKING DAYS NOTICE TO UTILITIES BEFORE YOU EXCAVATE, DRILL OR BLAST VIRGINIA UTILITY PROTECTION SERVICE, INC. TICKET NUMBER(S): APPROVED BY FREDERICK COUNTY ZONING ADMINISTRATOR SP#02-19 K: \ P r o j e c t s \ F C S A \ F C S A 1 6 0 5 - L a k e - F r e d e r i c k - E l e v - W a t e r - S t o r a g e \ D E S I G N \ _ P U B L I S H \ S h e e t s \ C S 0 0 0 1 . d w g PL O T T E D : 3/ 2 1 / 2 0 1 9 4 : 3 4 P M , B Y : Da v i d F r a n k PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S :   PERMIT DRAWINGS CS0001 BY NO . DA T E RE V I S I O N S FCSA1605 AS NOTED TEAM 2019-01-04 DAF/ERS SHEET APPROVED BY OF2 18 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PE N N O N I A S S O C I A T E S I N C . 11 7 E a s t P i c c a d i l l y S t r e e t Wi n c h e s t e r , V A 2 2 6 0 1 T 54 0 . 6 6 7 . 2 1 3 9 F 54 0 . 6 6 5 . 0 4 9 3 2/ 2 2 / 2 0 1 9 1 R E V I S E D P E R A G E N C Y C O M M E N T S KL M                                                  LA K E F R E D E R I C K E L E V A T E D W A T E R T A N K 18 2 0 F A I R F A X P I K E ST E P H E N S C I T Y V A . P. O . B O X 1 8 7 7 WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 FR E D E R I C K W A T E R NO T E S A N D L E G E N D S   VIRGINIA DEPARTMENT OF TRANSPORTATION STAUNTON DISTRICT REV. JUNE 19, 2013 VDOT GENERAL NOTES V1. ALL WORK ON THIS PROJECT SHALL CONFORM TO THE CURRENT EDITIONS OF AND LATEST REVISIONS TO THE VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT) ROAD AND BRIDGE SPECIFICATIONS AND STANDARDS, THE VIRGINIA EROSION AND SEDIMENT CONTROL REGULATIONS, AND ANY OTHER APPLICABLE STATE, FEDERAL OR LOCAL REGULATIONS. IN CASE OF A DISCREPANCY OR CONFLICT BETWEEN THE STANDARDS OR SPECIFICATIONS AND REGULATIONS, THE MOST STRINGENT SHALL GOVERN. V2. ALL CONSTRUCTION SHALL COMPLY WITH THE LATEST U.S. DEPARTMENT OF LABOR, OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA), AND VIRGINIA OCCUPATIONAL SAFETY & HEALTH (VOSH) RULES AND REGULATIONS. V3. WHEN WORKING WITHIN VDOT RIGHT-OF-WAY, ALL TRAFFIC CONTROL, WHETHER PERMANENT OR TEMPORARY, SHALL BE IN ACCORDANCE WITH THE CURRENT EDITION OF VDOT'S WORK AREA PROTECTION MANUAL. A TRANSPORTATION MANAGEMENT PLAN NEEDS TO BE SUBMITTED FOR APPROVAL AND LAND USE PERMIT ISSUED PRIOR TO ANY EXECUTION OF WORK WITHIN THE VDOT RIGHT OF WAY. V4 THE DEVELOPER SHALL BE RESPONSIBLE FOR RELOCATING, AT HIS EXPENSE, ANY AND ALL UTILITIES, INCLUDING TRAFFIC SIGNAL POLES, JUNCTION BOXES, CONTROLLERS, ETC., OWNED BY VDOT OR PRIVATE / PUBLIC UTILITY COMPANIES. IT IS THE SOLE RESPONSIBILITY OF THE DEVELOPER TO LOCATE AND IDENTIFY UTILITY FACILITIES OR ITEMS THAT MAY BE IN CONFLICT WITH THE PROPOSED CONSTRUCTION ACTIVITY. VDOT APPROVAL OF THESE PLANS DOES NOT INDEMNIFY THE DEVELOPER FROM THIS RESPONSIBILITY. V5. DESIGN FEATURES RELATING TO FIELD CONSTRUCTION, REGULATIONS, AND CONTROL OR SAFETY OF TRAFFIC MAY BE SUBJECT TO CHANGE AS DEEMED NECESSARY BY VDOT. ANY ADDITIONAL EXPENSE INCURRED AS A RESULT OF ANY FIELD REVISION SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. V6. IF REQUIRED BY THE LOCAL VDOT LAND DEVELOPMENT OFFICE, A PRE-CONSTRUCTION CONFERENCE SHALL BE ARRANGED AND HELD BY THE ENGINEER AND/OR DEVELOPER WITH THE ATTENDANCE OF THE CONTRACTOR (S), VARIOUS COUNTY AGENCIES, UTILITY COMPANIES AND VDOT PRIOR TO INITIATION OF WORK. V7. THE CONTRACTOR SHALL NOTIFY THE LOCAL VDOT LAND DEVELOPMENT OFFICE WHEN WORK IS TO BEGIN OR CEASE FOR ANY UNDETERMINED LENGTH OF TIME. VDOT REQUIRES AND SHALL RECEIVE 48 HOURS ADVANCE NOTICE PRIOR TO ANY REQUIRED OR REQUESTED INSPECTION. V8. THE CONTRACTOR SHALL NOTIFY THE TRAFFIC OPERATIONS CENTER AT (540) 332-9500 FOR ANY TRAFFIC CONTROL PLAN THAT IMPACTS A VDOT MAINTAINED INTERSTATE OR PRIMARY ROADWAY TO PROVIDE NOTIFICATION OF THE INSTALLATION AND REMOVAL OF THE WORK ZONE. V9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING A VDOT PERMITTED TEMPORARY CONSTRUCTION ENTRANCE(S) IN ACCORDANCE WITH SECTION 3.02 OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK. FURTHERMORE, ACCESS TO OTHER PROPERTIES AFFECTED BY THIS PROJECT SHALL BE MAINTAINED THROUGH CONSTRUCTION. V10.CONTRACTOR SHALL ENSURE ADEQUATE DRAINAGE IS ACHIEVED AND MAINTAINED ON THE SITE DURING AND AT THE END OF CONSTRUCTION. V11. ALL WATER AND SEWER LINES WITHIN EXISTING OR PROPOSED VDOT RIGHT-OF-WAY SHALL HAVE A MINIMUM THIRTY-SIX (36) INCHES COVER AND WHEN POSSIBLE SHALL BE INSTALLED UNDER ROADWAY DRAINAGE FACILITIES AT CONFLICT POINTS. V12.ANY UNUSUAL SUBSURFACE CONDITIONS (E.G., UNSUITABLE SOILS, SPRINGS, SINKHOLES, VOIDS, CAVES, ETC.) ENCOUNTERED DURING THE COURSE OF CONSTRUCTION SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER AND VDOT. WORK SHALL CEASE IN THAT VICINITY UNTIL AN ADEQUATE DESIGN CAN BE DETERMINED BY THE ENGINEER AND APPROVED BY VDOT. V13.ALL FILL AREAS, BORROW MATERIAL AND UNDERCUT AREAS SHALL BE INSPECTED AND APPROVED BY A VDOT REPRESENTATIVE PRIOR TO PLACEMENT OF FILL. A VDOT REPRESENTATIVE SHALL BE PRESENT TO INSURE THE SOIL SAMPLE(S) OBTAINED FOR CBR'S IS REPRESENTATIVE OF THE LOCATION. WHEN SOIL SAMPLES ARE SUBMITTED TO PRIVATE LABORATORIES FOR TESTING, THE SAMPLES SHALL BE CLEARLY IDENTIFIED AND LABELED AS BELONGING TO A PROJECT TO BE ACCEPTED BY VDOT AND THAT TESTING SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE VDOT STANDARDS AND PROCEDURES. V14.ALL ROADWAY FILL, BASE, SUBGRADE MATERIAL, AND BACKFILL IN UTILITY/STORM SEWER TRENCHES SHALL BE COMPACTED IN ACCORDANCE WITH THE LIFT THICKNESSES, DENSITY AND MOISTURE REQUIREMENTS AS SPECIFIED IN THE CURRENT VDOT ROAD AND BRIDGE SPECIFICATIONS. CERTIFIED COPIES OF TEST REPORTS SHALL BE SUBMITTED TO VDOT DAILY, UNLESS SPECIFIED OTHERWISE. V15.VDOT STANDARD CD AND UD UNDERDRAINS SHALL BE INSTALLED WHERE INDICATED ON THESE PLANS AND/OR AS SPECIFIED BY VDOT. V16. A POST INSTALLATION VISUAL/VIDEO CAMERA INSPECTION SHALL BE CONDUCTED BY THE CONTRACTOR ON ALL PIPES IDENTIFIED ON THE PLANS AS STORM SEWER PIPE AND A SELECT NUMBER OF PIPE CULVERTS. FOR PIPE CULVERTS, A MINIMUM OF ONE PIPE INSTALLATION FOR EACH SIZE OF EACH MATERIAL TYPE WILL BE INSPECTED OR TEN PERCENT OF THE TOTAL AMOUNT FOR EACH SIZE AND MATERIAL TYPE SUMMARIZED. ALL PIPE INSTALLATIONS ON THE PLANS NOT IDENTIFIED AS STORM SEWER PIPE SHALL BE CONSIDERED AS CULVERT PIPE FOR INSPECTION PURPOSES. ADDITIONAL TESTING MAY BE REQUIRED AS DIRECTED BY THE AREA LAND USE ENGINEER OR THEIR REPRESENTATIVE. V17.THE INSTALLATION OF ANY ENTRANCES AND MAILBOXES WITHIN ANY DEDICATED STREET RIGHT-OF-WAY SHALL MEET VDOT MINIMUM DESIGN STANDARDS AND IS THE RESPONSIBILITY OF THE DEVELOPER. V18.PRIOR TO VDOT ACCEPTANCE OF ANY STREETS, ALL REQUIRED STREET SIGNAGE AND/OR PAVEMENT MARKINGS SHALL BE INSTALLED BY THE DEVELOPER IN ACCORDANCE WITH THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. V19.THE DEVELOPER SHALL PROVIDE THE VDOT LAND DEVELOPMENT OFFICE WITH A LIST OF ALL MATERIAL SOURCES PRIOR TO THE START OF CONSTRUCTION. COPIES OF ALL INVOICES FOR MATERIALS UTILIZED WITHIN ANY DEDICATED STREET RIGHT-OF-WAY MUST BE PROVIDED TO THE LOCAL VDOT LAND DEVELOPMENT OFFICE PRIOR TO ACCEPTANCE OF THE WORK. UNIT AND TOTAL PRICES MAY BE OBSCURED. V20.AGGREGATE BASE AND SUBBASE MATERIALS SHALL BE PLACED ON SUBGRADE BY MEANS OF A MECHANICAL SPREADER. DENSITY WILL BE DETERMINED USING THE DENSITY CONTROL STRIP IN ACCORDANCE WITH SECTION 304 OF THE VDOT ROAD AND BRIDGE SPECIFICATIONS AND VTM-10. A CERTIFIED COMPACTION TECHNICIAN SHALL PERFORM THESE TESTS. CERTIFIED COPIES OF TEST REPORTS SHALL BE SUBMITTED TO VDOT DAILY, UNLESS SPECIFIED OTHERWISE. IN ADDITION TO CHECKING STONE DEPTHS, A VDOT REPRESENTATIVE SHALL BE NOTIFIED AND GIVEN THE OPPORTUNITY TO BE PRESENT DURING THE CONSTRUCTION AND TESTING OF THE DENSITY CONTROL STRIP. V21.ASPHALT CONCRETE PAVEMENTS SHALL BE PLACED IN ACCORDANCE WITH SECTION 315 OF THE VDOT ROAD AND BRIDGE SPECIFICATIONS. DENSITY SHALL BE DETERMINED USING THE DENSITY CONTROL STRIP AS SPECIFIED IN SECTION 315 AND VTM-76. A CERTIFIED COMPACTION TECHNICIAN SHALL PERFORM THESE TESTS. CERTIFIED COPIES OF TEST REPORTS SHALL BE SUBMITTED TO VDOT DAILY, UNLESS SPECIFIED OTHERWISE. A VDOT REPRESENTATIVE SHALL BE NOTIFIED AND GIVEN THE OPPORTUNITY TO BE PRESENT DURING THE CONSTRUCTION AND TESTING OF THE CONTROL STRIP. V22.IN ACCORDANCE WITH SECTION 302.03, THE FOUNDATIONS FOR PIPE CULVERTS THIRTY-SIX (36) INCHES AND LARGER SHALL BE EXPLORED BELOW THE BOTTOM OF THE EXCAVATION TO DETERMINE THE TYPE AND CONDITION OF THE FOUNDATION. THE CONTRACTOR SHALL REPORT FINDINGS OF FOUNDATION EXPLORATION TO THE ENGINEER AND VDOT FOR APPROVAL PRIOR TO PLACING PIPE. FOUNDATION DESIGNS SHALL COMPLY WITH VDOT ROAD AND BRIDGE STANDARD PB-1. WHERE SOFT, YIELDING, OR OTHERWISE UNSUITABLE FOUNDATION IS ENCOUNTERED, THE FOUNDATION DESIGN AND/OR NEED FOR FOUNDATION STABILIZATION SHALL BE DETERMINED BY THE ENGINEER AND APPROVED BY VDOT. V23.VDOT STANDARD GUARDRAIL SHALL BE INSTALLED WHERE WARRANTED AND/OR AS PROPOSED ON THESE PLANS IN ACCORDANCE WITH VDOT'S INSTALLATION CRITERIA. FINAL APPROVAL OF THE GUARDRAIL LAYOUT TO BE GIVEN BY VDOT AFTER GRADING IS MOSTLY COMPLETE. V24.APPROVAL OF THESE PLANS SHALL EXPIRE FIVE (5) YEARS FROM THE DATE OF THE APPROVAL LETTER. V25.VDOT STANDARD CG-12 CURB RAMPS SHALL BE INSTALLED WHERE INDICATED ON THESE PLANS AND/OR AS SPECIFIED BY VDOT. V26.THE FOUNDATIONS FOR ALL BOX CULVERTS SHALL BE INVESTIGATED BY MEANS OF EXPLORATORY BORINGS ADVANCED BELOW PROPOSED FOUNDATION ELEVATION TO DETERMINE THE TYPE AND CONDITION OF THE FOUNDATION. THE CONTRACTOR SHALL SUBMIT COPIES OF BOREHOLE LOGS AND REPORT FINDINGS OF FOUNDATION EXPLORATION TO THE ENGINEER AND VDOT FOR APPROVAL PRIOR TO CONSTRUCTING BOX. FOUNDATION DESIGNS SHALL COMPLY WITH VDOT ROAD AND BRIDGE STANDARD PB-1. CONTRARY TO THE STANDARD, WHERE ROCK IS ENCOUNTERED AND CAST-IN-PLACE BOX IS PROPOSED, THE THICKNESS OF BEDDING SHALL BE SIX (6) INCHES. WHERE SOFT, YIELDING, OR OTHERWISE UNSUITABLE FOUNDATION IS ENCOUNTERED, THE FOUNDATION DESIGN AND/OR NEED FOR FOUNDATION STABILIZATION SHALL BE DETERMINED BY THE ENGINEER AND APPROVED BY VDOT. CONSTRUCTION NOTES GENERAL 1. THE CONTRACTOR SHALL FURNISH ALL MATERIALS, LABOR AND EQUIPMENT AND PERFORM ALL WORK INCLUDING RESTORATION FOR ALL IMPROVEMENTS SHOWN OR IMPLIED AS NECESSARY FOR THE COMPLETED FACILITY READY FOR USE. UNLESS OTHERWISE NOTED, SPECIFICATIONS FOR ALL WORK TO BE IN ACCORDANCE WITH APPLICABLE STANDARDS AND CONSTRUCTION SPECIFICATIONS OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION, VIRGINIA DEPARTMENT OF HEALTH, ECONOMIC DEVELOPMENT AUTHORITY, AND THE CONTRACT DOCUMENTS. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION STAKEOUT. ALL DIMENSIONS, ELEVATIONS AND LOCATIONS SHALL BE VERIFIED IN THE FIELD BY EACH CONTRACTOR PRIOR TO BEGINNING THE WORK. THE ENGINEER WILL APPROVE ALL CUT SHEETS. 3. CONSTRUCTION ACTIVITIES SHALL BE LIMITED TO THE HOURS OF 8:00 AM TO 5:00 PM. 4. ANY UNUSUAL SUBSURFACE CONDITIONS ENCOUNTERED DURING THE COURSE OF THE WORK SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER AND/OR THE OWNER. 5. CONTRACTOR TO OBTAIN, AT HIS EXPENSE, ALL PERMITS REQUIRED OF THIS WORK PRIOR TO COMMENCING CONSTRUCTION AND SHALL FAITHFULLY ADHERE TO THE PERMIT CONDITIONS IMPOSED. 6. ALL GRADING FOR IMPROVEMENTS TO BE CONFINED TO THE PROJECT AREA. ANY WORK PERFORMED OFFSITE IS THE CONTRACTOR'S RESPONSIBILITY. DUE TO THE PROXIMITY OF THE PROJECT TO EXISTING STRUCTURES AND UTILITIES, BLASTING WILL NOT BE ALLOWED. 7. CUTSHEETS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO CONSTRUCTION. ALL CUTSHEETS SHOULD SHOW EXISTING GROUND ELEVATIONS AT CENTERLINE OF UTILITY, STRUCTURE OR ROAD, AND OFFSET HUB ELEVATION. 8. LOCATIONS OF UTILITIES SHOWN ARE APPROXIMATE. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING THE EXACT LOCATION, VERTICALLY AND HORIZONTALLY, OF THE UTILITIES PRIOR TO ANY EXCAVATION OR CONSTRUCTION. THE CONTRACTOR SHALL CONTACT "MISS UTILITY" AND ALL APPLICABLE UTILITY COMPANIES FOR CLEARANCE PRIOR TO EXCAVATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADHERING TO THE COMMONWEALTH OF VIRGINIA UNDERGROUND UTILITY DAMAGE PREVENTION ACT, CHAPTER 10, TITLE 56 OF THE CODE OF VIRGINIA. 9. CONTRACTOR SHALL BE RESPONSIBLE FOR IMPLEMENTING AND MAINTAINING ALL EROSION AND SEDIMENT CONTROL MEASURES NECESSARY DURING CONSTRUCTION IN ACCORDANCE WITH CURRENT STATE AND LOCAL REGULATIONS. DISTURBED AREAS SHALL NOT REMAIN DENUDED FOR MORE THAN SEVEN (7) CALENDAR DAYS WHEN CONSTRUCTION IS NOT IN PROGRESS. DURING CONSTRUCTION, ALL STORM SEWER INLETS SHALL BE PROTECTED BY INLET PROTECTION, AND SHALL BE MAINTAINED AND MODIFIED AS REQUIRED BY CONSTRUCTION PROGRESS. CONTRACTOR SHALL CONTACT THE COUNTY BUILDING INSPECTIONS OFFICE AT (540) 636-9973 TO SCHEDULE INSPECTIONS. 10. CONTRACTOR SHALL PROVIDE ADEQUATE MEANS OF CLEANING MUD FROM TRUCKS AND/OR OTHER EQUIPMENT PRIOR TO ENTERING PUBLIC STREETS AND/OR EXISTING PARKING LOTS AND OTHER PAVED AREAS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CLEAN STREETS, ALLAY DUST, AND TO TAKE WHATEVER MEASURES NECESSARY TO ENSURE THAT THE STREETS ARE MAINTAINED IN A CLEAN, MUD AND DUST FREE CONDITION AT ALL TIMES. 11. ANY STREET OR UTILITIES DAMAGED BY CONTRACTOR OR SUB-CONTRACTOR SHALL BE SOLE RESPONSIBILITY OF THE PRIMARY CONTRACTOR AND PROPERLY AND IMMEDIATELY REPAIRED BY THE CONTRACTOR. SUCH REPAIRS SHALL BE TO THE ORIGINAL CONDITION, IN COMPLIANCE WITH THE TOWN'S CONSTRUCTION STANDARDS & SPECIFICATIONS, AND TO THE SATISFACTION OF THE TOWN INSPECTOR. 12. ALL PRE-CAST CONCRETE STRUCTURES SHALL BE A MINIMUM 4000 PSI AT 28 DAYS. 13. THE CONTRACTOR IS RESPONSIBLE FOR ADJUSTMENT OF ALL UTILITY BOXES, VAULTS, OR OTHER APPURTENANCES TO NEW FINISHED GRADE ELEVATIONS. 14. CONTRACTOR TO RELOCATE ALL SIGNS AND UTILITIES REQUIRED FOR THIS WORK. 15. ANY PLANNED DISRUPTIONS OF OR TIE INS TO EXISTING UTILITIES SHALL BE COORDINATED WITH THE APPROPRIATE UTILITY OWNER. WITH THE EXCEPTION OF EMERGENCIES, THERE SHALL BE A MINIMUM OF 24 HOURS NOTICE GIVEN BY THE CONTRACTOR TO ALL RESIDENTIAL, COMMERCIAL, AND INDUSTRIAL UTILITY USERS AFFECTED BY UTILITY INTERRUPTIONS. 16. THE UNAUTHORIZED USE OF WATER WITHOUT DUE COMPENSATION IS ILLEGAL. NO PERSON SHALL CONNECT TO OR DO ANY WORK ON THAT PORTION OF THE SYSTEM OWNED BY THE TOWN UNLESS WRITTEN AUTHORIZATION IS RECEIVED PRIOR TO COMMENCING WORK. 17. CONSTRUCTION LIMITS SHALL BE PROPERTY LINES OR AS INDICATED BY PLAN REQUIREMENTS AND SHALL BE STAKED OR FLAGGED IN THE FIELD PRIOR TO CONSTRUCTION. 18. CONSTRUCTION SHALL CONFORM TO THE AMERICAN WITH DISABILITIES ACT (ADA) REQUIREMENTS. 19. REGISTERED LAND DISTURBER TO SUBMIT REPORTS TO BUILDING INSPECTOR ON A REGULAR BASIS AS REQUIRED BY FREDERICK COUNTY. FIRE AND RESCUE 1. BURNING OF CONSTRUCTION DEBRIS AND CLEARING AND GRUBBING DEBRIS ON SITE IS PROHIBITED. 2. ACCESS FOR EMERGENCY VEHICLES MUST BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION. EROSION CONTROL 1. A LAND DISTURBANCE PERMIT WILL BE REQUIRED PRIOR TO INITIATING ANY SITE WORK. THIS PERMIT CAN BE OBTAINED FROM THE FREDERICK COUNTY DEPARTMENT OF PUBLIC WORKS. A PRECONSTRUCTION CONFERENCE SHALL BE HELD ON SITE PRIOR TO INITIATING ANY WORK. 2. TEMPORARY AND PERMANENT EROSION CONTROL STRUCTURES AND METHODS TO BE IN ACCORDANCE WITH THE VIRGINIA EROSION CONTROL GUIDELINES AND LOCAL ORDINANCES AND TO BE UTILIZED DURING THE CONSTRUCTION PERIOD. 3. ALL EROSION CONTROL STRUCTURES SHOWN OR AS REQUIRED DURING CONSTRUCTION SHALL BE CONTINUOUSLY MAINTAINED THROUGHOUT THE PERIOD IN WHICH AREAS ARE DENUDED. AREAS SHOWN TO BE SURFACED ARE TO HAVE STONE BASE INSTALLED AT THE EARLIEST POSSIBLE DATE AFTER ESTABLISHING GRADE. NO AREA IS TO REMAIN DENUDED FOR MORE THAN 7 CALENDAR DAYS WHEN CONSTRUCTION IS NOT IN PROGRESS. 4. CONTRACTOR TO CLEAN UP AND RESTORE DISTURBED AREAS IMMEDIATELY UPON COMPLETION OF PIPE-LAYING IN THE AFFECTED AREA. 5. ALL UNPAVED AREAS OF THE SITE WHICH ARE DISTURBED BY THIS CONSTRUCTION SHALL BE PROVIDED WITH 4" TOPSOIL, FERTILIZED, SEEDED, COMPACTED AND MULCHED. SEED BED TO BE WATERED AND CARED FOR AS NECESSARY TO PROVIDE A GOOD LAWN QUALITY GRASS COVER. DENUDED AREAS NOT GRADED SHALL BE DISCED, LEVELED AND SEEDED TO ACHIEVE LAWN CONDITIONS. 6. ALL EROSION CONTROL MEASURES TO BE MAINTAINED IN ACCORDANCE WITH VESCH HANDBOOK. ELEVATED WATER TANK 0.88 ACRES TAX IDENTIFICATION NUMBER SITE DEVELOPMENT SUMMARY SITE ADDRESS CURRENT USE PROPOSED USE DISTURBED AREA VACANT PARKING SCHEDULE SF SQUARE FEET SEC SECTION RTE ROUTE ROW RIGHT-OF-WAY FT FEET POLYVINYL CHLORIDE REINFORCED CONCRETE PIPE VIRGINIA DEPARTMENT OF TRANSPORTATION WELDED WIRE MESH POINT OF VERTICAL INTERSECTION W/ FIRE HYDRANTF.H. WV WATER VALVE BEST MANAGEMENT PRACTICE BEGIN VERTICAL CURVE STATION BEGIN VERTICAL CURVE ELEVATION END VERTICAL CURVE STATION END VERTICAL CURVE ELEVATION DROP INLET DIAMETER DUCTILE IRON PIPE EROSION CONTROL ELEVATION END SECTION FINISHED FLOOR ELEVATION ELEV F.F.E. EVCS EX EVCE ES EXISTING DIP EA EC DIA DI EACH BENCHMARK CLEANOUT CONCRETECONC CL CO BVCS BVCE CLASS BLDG B.M. BMP BUILDING STR VERT WWM TYP VDOT RCP SHT STM PVC PVI STRUCTURE TYPICAL VERTICAL WITH SHEET STEAM HORIZ MECH MIN MSE INV MAX G.V. HORIZONTAL INVERT MAXIMUM MECHANICAL MINIMUM MECHANICALLY STABILIZED EARTH GATE VALVE AREA DRAINAD TRENCH DRAINTD LIMITS OF DISTURBANCELOD APPX. APPROXIMATELY OVERHEAD ELECTRICOHE UNDERGROUND ELECTRICUGE UGT UNDERGROUND TELEPHONE TELCO TELECOMMUNICATIONS WWF WELDED WIRE FABRIC CAST IRONCI STAINLESS STEELSS TREE PROTECTIONTP NORTH BOUND LANENBL SOUTH BOUND LANESBL BW BOTTOM OF WALL TOP OF WALLTW ON CENTER EACH WAY ON CENTEROC OCEW PROP PROPOSED DIAMETERØ MANHOLEMH FOR FUEL OIL RETURN FOS FUEL OIL SUPPLY CWR CWS CHILLED WATER SUPPLY CHILLED WATER RETURN MECHANICAL, ELECTRICAL, PLUMBINGMEP ABBREVIATIONS MLP METAL LIGHT POLE MSP METAL SIGN POLE F.H. ASSY FIRE HYDRANT ASSEMBLY HANDICAP PARKINGHCP R5EXISTING ZONING BUILDING RESTRICTION LINEBRL PARKING SPACES PROPOSED OPEQUON MAGISTERIAL DISTRICTMAGISTERIAL DISTRICT PRESENT OWNER 4.366 ACRESTOTAL PARCEL ACREAGE 0.31 ACRES ON-SITE IMPERVIOUS AREA 2 20. ANY OUTDOOR SITE LIGHTING SHALL BE IN CONFORMANCE WITH SECTION 165-201.07 OF THE FREDERICK COUNTY CODE. NONEWATER AND SEWER DEMAND WATER AND SEWER DEMAND FREDERICK COUNTY SANITATION AUTHORITY INSTR# 190000230 GENERAL NOTES: 1. ALL CONSTRUCTION SHALL CONFORM TO CURRENT FREDERICK COUNTY AND VIRGINIA DEPARTMENT OF TRANSPORTATION STANDARDS AND SPECIFICATIONS, AND ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS. 2. THE PARCEL SHOWN ON THIS SITE PLAN IS IDENTIFIED ON FREDERICK COUNTY PARCEL MAP BY THE TAX MAP NUMBER 87-A-102A AND ZONED R5. THE PROPERTY IS OWNED BY FREDERICK COUNTY SANITATION AUTHORITY AS RECORDED AMONG THE LAND RECORDS OF FREDERICK COUNTY VA, AT INST#190000230. 3. BOUNDARY AND TOPOGRAPHIC INFORMATION DEPICTED HEREON IS BASED ON A FIELD SURVEY PREPARED BY MARSH & LEGGE ON DECEMBER 22, 2016, AND FURTHER SUPPLEMENTED ON SEPTEMBER 8, 2017. GRID BASED ON VIRGINIA STATE PLANE COORDINATE SYSTEM NORTH ZONE NAD 1983. VERTICAL DATUM BASED ON NAVD1988. 4. THE APPROVAL OF THESE PLANS SHALL IN NO WAY RELIEVE THE DEVELOPER OR HIS AGENT OF ANY LEGAL RESPONSIBILITY WHICH MAY BE REQUIRED BY THE CODE OF VIRGINIA OR ANY OTHER ORDINANCE ENACTED BY THE COUNTY OF FREDERICK. 5. STANDARD GUARD AND HAND RAILS SHALL BE INSTALLED AT HAZARDOUS LOCATIONS AS DESIGNATED DURING FINAL FIELD INSPECTION BY FREDERICK COUNTY AND/OR VIRGINIA DEPARTMENT OF TRANSPORTATION. 6. CONTROLLED FILLS MUST BE COMPACTED TO 95% AS DETERMINED PER STANDARD PROCTOR T-99 OR ASTM B698. DENSITY MUST BE CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER AND RESULTS SUBMITTED TO THE COUNTY OF WARREN PRIOR TO FOOTING CONSTRUCTION. THE COUNTY WILL ONLY INSPECT CONTROLLED FILLS AS THEY RELATE TO INSTALLATION OF COUNTY MAINTAINED WATERLINES AND SANITARY SEWER LINES. RESPONSIBILITY FOR INSPECTION ON CONTROLLED FILLS UNDER FOOTING WILL FALL TO THE OWNER'S DESIGNEE. 7. AT LEAST 10 DAYS PRIOR TO CONSTRUCTION ACTIVITY, THE CONTRACTOR MUST OBTAIN ITS TEST PIT DATA AS INDICATED ON THE PLAN SET AND COORDINATE WITH THE INSPECTOR. IF THE TEST RESULTS SHOW A POTENTIAL CONFLICT OR NON-COMPLIANCE WITH THE APPROVED PLAN, REVISIONS TO THE PLAN MUST BE SUBMITTED FOR APPROVAL. IN SUCH INSTANCES, NO WORK SHALL COMMENCE UNTIL CONFLICTS ARE RESOLVED AND REVISIONS APPROVED. 8. ALL CONTROLLED FILL, BASE, SUBBASE AND SUBGRADE MATERIALS SHALL BE COMPACTED TO 95% OF THEORETICAL MAXIMUM DRY DENSITY AS DETERMINED BY AASHTO T-99 A, WITHIN ±2% OF OPTIMUM MOISTURE FOR THE FILL OF ANY DEDICATED RIGHT-OF-WAY AND ALL TOWNHOUSE, COMMERCIAL AND INDUSTRIAL PARKING LOTS; PRIVATE STREETS; PARKING BAYS; CURB AND GUTTER; AND SIDEWALKS ADJACENT TO STREETS AND PARKING LOTS(NOT INTENDED TO INCLUDE LEADWALKS). DENSITY MUST BE VERIFIED BY A QUALIFIED SOILS ENGINEER. CONTROLLED FILLS SHALL BE COMPACTED IN NO GREATER THAN EIGHT-INCH LIFTS (LOOSE THICKNESS) TO THE SPECIFIED BEGINNING FROM THE EXISTING GROUND SURFACE, UNLESS OTHERWISE APPROVED IN WRITING BY A QUALIFIED SOILS ENGINEER AND THE DIRECTOR OF PUBLIC WORKS. CONTROLLED FILL MATERIAL TO BE SPECIFIED BY GEOTECHNICAL ENGINEER. 9. ALL EXISTING UNDERGROUND UTILITIES , UNLESS OTHERWISE NOTED ON PLAN SET, SHALL BE PHYSICALLY LOCATED BY THE CONTRACTOR PRIOR TO THE BEGINNING OF ANY CONSTRUCTION IN THE VICINITY OF SAID UTILITIES. WHEN DURING THE COURSE OF CONSTRUCTION ANY OBSTACLE OF A DUBIOUS NATURE IS ENCOUNTERED, THE CONTRACTOR SHALL CEASE IN THAT AREA IMMEDIATELY NOTIFY THE PROPER AUTHORITY, FREDERICK COUNTY, AND/OR THE ENGINEER. 10. NO BLASTING IS PERMITTED WITHIN 25' OF EXISTING WATER AND SEWER UTILITIES. 11. A SMOOTH GRADE SHALL BE MAINTAINED FROM THE CENTERLINE OF THE EXISTING ROAD TO THE PROPOSED EDGE OF PAVEMENT TO PRECLUDE THE FORMING OF FALSE GUTTERS AND/OR PONDING OF WATER IN THE ROADWAY. 12. EMERGENCY VEHICLE ACCESS SHALL BE PROVIDED DURING CONSTRUCTION. 13. ALL EXISTING STRUCTURES, TANKS, FARM DUMPS, ETC., SHALL BE CAREFULLY REMOVED AND DISPOSED OF AT AN APPROVED WASTE DISPOSAL SITE. 14. THE APPLICANT AND/OR CONTRACTOR SHALL HAVE A CLEARLY READABLE COPY OF THE APPROVED PLANS AND SPECIFICATIONS AVAILABLE ON THE PROPERTY AT ALL TIMES. 15. ALL DAMAGE RESULTING FROM CONSTRUCTION OPERATIONS TO STREETS, ROADS, HIGHWAYS, SHOULDERS, DITCHES, EMBANKMENTS, CULVERTS, BRIDGES, SANITARY SEWER, WATER MAINS OR OTHER PUBLIC OR PRIVATE PROPERTY OR FACILITY, REGARDLESS OF LOCATION OR CHARACTER, WHICH MAY BE CAUSED BY CONSTRUCTION AND/OR MOVING, HAULING, OR OTHERWISE TRANSPORTING EQUIPMENT, MATERIALS OR MEN TO OR FROM THE WORK OR ANY PART OF THE SITE THEREOF, SHALL BE THE RESPONSIBILITY OF THE APPLICANT, HIS CONTRACTOR OR SUBCONTRACTOR. 16. APPROVAL OF THIS PLAN SHALL IN NO WAY GRANT PERMISSION BY THE COUNTY FOR THE DEVELOPER TO TRESPASS ON OFFSITE PROPERTIES. 17. NO BUILDING OR OTHER STRUCTURE SHALL BE LOCATED IN A MANNER OR BUILT TO A HEIGHT WHICH CONSTITUTES A HAZARD TO AIR TRAFFIC WITHOUT CERTIFICATION FROM THE FEDERAL AVIATION ADMINISTRATION. 18. THE APPROVAL OF THIS PLAN SHALL IN NO WAY RELIEVE THE OWNER OF COMPLYING WITH OTHER APPLICABLE LOCAL, STATE AND FEDERAL REQUIREMENTS. 19. ACCORDING TO THE NATIONAL WETLANDS INVENTORY THERE IS A 0.20 ACRE FRESHWATER POND AND A RIVERINE PRESENT WITHIN THE LIMITS OF THE OVERALL PROPERTY. HOWEVER, THEY ARE NOT LOCATED WITHIN THE LIMITS OF THIS PROJECT. THIS INFORMATION WAS INTERPRETED USING 1:58,000 SCALE, COLOR INFRARED IMAGERY FROM 1982. 20. NO FLOODPLAIN EXISTS ON THE PROPERTY THAT IS THE SUBJECT OF THIS APPLICATION. THE CURRENT FLOOD INSURANCE RATE MAP (FIRM) OF FREDERICK COUNTY PANEL NUMBER FOR THE PROPERTY THAT IS THE SUBJECT OF THIS APPLICATION IS 51069C0350D, EFFECTIVE SEPTEMBER 2, 2009. 21. PLANTING AND MAINTENANCE OF MATERIALS SHALL BE DONE ACCORDING TO GUIDELINES SET FORTH IN THE VIRGINIA EROSION AND SEDIMENTATION CONTROL HANDBOOK AND ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS. CG-6 ASPHALT LIMITS OF DISTURBANCE DESCRIPTION WATERLINE SPOT ELEVATION CONTOURS SANITARY SEWER WITH MANHOLE PROPERTY LINE SIGN POST EXISTING LEGEND NEW GATE VALVE FIRE HYDRANT ASSEMBLY BUILDING CG-6R HY D UNDERGROUND ELECTRIC SERVICEE LIGHT POLE W S 628.90 TC CONCRETE TREELINE BUILDING SETBACKS (R5 ZONING) FRONT 35' REQUIRED PROVIDED +/-163'SIDE 15'+/-51'DAVID L. FRANK Lic. No.1061   SIDE 15'+/-254' FRONT 70' REQUIRED PROVIDED 79.5'SIDE (MADISON FARMS)100'100.0'SIDE (SOUTH)250'280.3' ELEVATED TANK SETBACKS CODE: 165-204.26A (1/9/2019) REAR 50'N/A “SETBACKS APPLICABLE TO THE PROPOSED ELEVATED WATER STORAGE TANK:  THE BASE OF THE ELEVATED WATER STORAGE TANK WILL BE A MINIMUM OF 70-FT FROM ROUTE 277 (FAIRFAX PIKE), 100-FT FROM THE MADISON FARMS, LLC PROPERTY TO THE WEST, AND 250-FT FROM THE SOUTHERN PROPERTY LINE.   THESE SETBACKS RESULT IN AN ELEVATED WATER STORAGE TANK LOCATION THAT ACCOMMODATES THE DEDICATION OF 20-FT FOR FUTURE FAIRFAX PIKE EXPANSION, AND AVOIDS PLACING THE TANK WITHIN THE PLANNED SOUTH FREDERICK PARKWAY ALIGNMENT.  THE ZONING ADMINISTRATOR, PER FREDERICK COUNTY CODE 165-204.26.A. PUBLIC UTILITIES, AND REFLECTIVE OF THE APPROVAL OF THE SITE PLAN, HAS DETERMINED THAT THESE ARE APPROPRIATE SETBACKS APPLICABLE FOR THE ELEVATED WATER  STORAGE TANK ON THIS SITE.” 87-A-102A FAIRFAX PIKE PARKING SPACES REQUIRED 1 (1 PER EMPLOYEE) H.C. PARKING SPACES REQUIRED 1 (VAN ACCESSIBLE)H.C. PARKING SPACES PROPOSED 1(VAN ACCESSIBLE) SIGNAGE THERE IS NO NEW, PROPOSED, OR MODFICATION TO EXISTING SIGNAGE WITH THIS SITE PLAN. ANY FUTURE SIGNAGE WILL CONFORM WITH SECTION 165-201.06 OF THE FREDERICK COUNTY ZONING ORDINANCE. MONUMENT SIGNAGEREQUIRES A SEPARATE BUILDING PERMIT FOR CONSTRUCTION. NO SITE LIGHTING IS PROPOSED WITH THIS SITE PLAN. ANY FUTURE SITE LIGHTING WILL CONFORM TO SECTION 165-201.07, OUTDOOR LIGHTING STANDARDS, OF THE FREDERICK COUNTY ZONING ORDINANCE. ANY LIGHTING REQUIRED BY THE FAA IS EXEMPT FROM THE REQUIREMENTS OF THE FREDERICK COUNTY ZONING ORDINANCE. LIGHTING 0.02 ACRES OFF-SITE 0.33 ACRES TOTAL K: \ P r o j e c t s \ F C S A \ F C S A 1 6 0 5 - L a k e - F r e d e r i c k - E l e v - W a t e r - S t o r a g e \ D E S I G N \ _ P U B L I S H \ S h e e t s \ C S 1 0 0 0 . d w g PL O T T E D : 3/ 2 1 / 2 0 1 9 4 : 3 4 P M , B Y : Da v i d F r a n k PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S :   PERMIT DRAWINGS CS1000 BY NO . DA T E RE V I S I O N S FCSA1605 AS NOTED TEAM 2019-01-04 DAF/ERS SHEET APPROVED BY OF3 18 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PE N N O N I A S S O C I A T E S I N C . 11 7 E a s t P i c c a d i l l y S t r e e t Wi n c h e s t e r , V A 2 2 6 0 1 T 54 0 . 6 6 7 . 2 1 3 9 F 54 0 . 6 6 5 . 0 4 9 3 2/ 2 2 / 2 0 1 9 1 R E V I S E D P E R A G E N C Y C O M M E N T S KL M                                                  LA K E F R E D E R I C K E L E V A T E D W A T E R T A N K 18 2 0 F A I R F A X P I K E ST E P H E N S C I T Y V A . P. O . B O X 1 8 7 7 WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 FR E D E R I C K W A T E R MA I N T E N A N C E O F T R A F F I C   DAVID L. FRANK Lic. No.1061   PIN 87-A-102A FREDERICK COUNTY SANITATION AUTHORITY INST. 190000230 VA . R O U T E 2 7 7 - F A I R F A X P I K E (6 0 ' R / W ) 15' BUILDING SETBACK 3 5 ' B U I L D I N G S E T B A C K R I G H T O F W A Y P R O P E R T Y L I N E 1 5 ' B U I L D I N G S E T B A C K LIMITS OF DISTURBANCE PERMIT DRAWINGS CS2000 BY NO . DA T E RE V I S I O N S FCSA1605 1" = 30' TEAM 2019-01-04 DAF/ERS SHEET APPROVED BY OF4 18 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 30'60' PE N N O N I A S S O C I A T E S I N C . 11 7 E a s t P i c c a d i l l y S t r e e t Wi n c h e s t e r , V A 2 2 6 0 1 T 54 0 . 6 6 7 . 2 1 3 9 F 54 0 . 6 6 5 . 0 4 9 3 2/ 2 2 / 2 0 1 9 1 R E V I S E D P E R A G E N C Y C O M M E N T S KL M                                                  LA K E F R E D E R I C K E L E V A T E D W A T E R T A N K 18 2 0 F A I R F A X P I K E ST E P H E N S C I T Y V A . P. O . B O X 1 8 7 7 WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 FR E D E R I C K W A T E R EX I S T I N G C O N D I T I O N S P L A N   NORT H NOTES: 1. TOPOGRAPHIC INFORMATION SHOWN HEREON IS BASED ON AN ACTUAL FIELD SURVEY COMPLETED DECEMBER 16, 2016. 2. ANY UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. THE SURVEYOR MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM INFORMATION AVAILABLE. 3. HORIZONTAL ORIENTATION IS BASED ON VA. NAD 83 NORTH ZONE STATE GRID; VERTICAL DATUM IS BASED ON NAVD 88 ELEVATIONS ESTABLISHED USING GPS METHODS. ABBREVIATION DEFINITION BLOW OFF (FLUSHING HYDRANT) FIRE HYDRANT GUY ANCHOR INVERT POLYVINYLCHLORIDE PIPE REINFORCED CONCRETE PIPE WATER LINE MARKER WOOD POST WOOD POWER POLE WATER VALVE LEGEND IRON PIPE FOUND Marsh & Legge Land Surveyors, P.L.C. 560 NORTH LOUDOUN STREET ~ WINCHESTER, VIRGINIA 22601 PHONE (540) 667-0468 ~ FAX (540) 667-0469 ~ EMAIL office@marshandlegge.com www.marshandlegge.com TOPOGRAPHIC SURVEY OF A PORTION OF THE LAND OF MREC SHENANDOAH VA, LLC INSTRUMENT NUMBER 130010885 OPEQUON MAGISTERIAL DISTRICT FREDERICK COUNTY, VIRGINIA OUT L E T INL E T 12" W A T E R L I N E D I P C L - 5 2 EX . 1 2 ' W A T E R L I N E EX. 12' WATERLINE 10+0 0 10+5 0 11+ 0 0 11+ 5 0 11+ 6 8 12" WET TAP AND GATE VALVE TO BE PROVIDED BY FREDERICK WATER 12" X 12" X 8" MJ TEE 8" MJ GATE VALVE 12" MJ GATE VALVE 12" MJ GATE VALVE 12" X 8" TEE 8" MJ GATE VALVE (2) 45° BENDS 5+00 5+50 6+0 0 6+5 0 6+8 2 1- FH ASSY. REMOVE EXISTING 12" PVC WATERLINE FROM GATE VALVE TO PLUG AND REPLACE WITH 12" DIP PR V22.5° BEND 254 . 9 9 ' 153.6 3 ' 1 0 0 . 0 ' ( F O U N D A T I O N ) 79.5'(FOU N D A T I O N ) 2 0 ' 20 ' ASP H A L T ACC E S S R O A D 40' DIA. PEDISTAL WITH 10" WALL 50.35' DIA. RESERVOIR 51' DIA. FOUNDATION 57' DIA. ELEVATED WALKWAY ELEVATED STORAGE TANK FFE = 708.00 PR O P O S E D P E - 1 ST A N D A R D P R I V A T E EN T R A N C E 25'R 2 5 ' R FUT U R E S T O R A G E S H E D / OPT I O N A L O U T D O O R S T O R A G E A R E A PROPOSED 6' CHAIN LINK FENCE 6' BOARD ON BOARD FENCE IS REQUIRED IF THIS AREA IS UTILIZED FOR OUTDOOR STORAGE PROPOSED H.C. SIGN 10' ROLL-UP DOOR3' DOOR OHE (BY POWER COMPANY) UGE PROPOSED CONC. WHEELSTOP (TYP. OF 2) SWM POND PROPOSED 22' DOUBLE-SWING GATE 3 0 ' 60' 2 8 0 . 3 ' ( F O U N D A T I O N ) 2 1 0 . 0 0 ' 8. 0 0 ' 8. 0 0 ' 18.0 0 ' 5' 20' E M E R . VEH I C L E ACC E S S 2 0 ' E M E R . V E H I C L E A C C E S S 28'R 28 ' R 51 . 2 3 ' OVERFLOW OUTLET 88' 7 0 ' FOR FLOOR PLAN DETAIL SEE SHEET 153' 21A STONE (TYP.) 3' 21A STONE (TYP.) OVERFLOW / DRAIN STRUCTURE 12" OVERFLOW / DRAIN PIPE ROCK OUTLET PROTECTION STANDARD EC-1 TYPE A MIN. APRON LENGTH = 10' MIN. UPSTREAM WIDTH = 6' MIN. DOWNSTREAM WIDTH = 12' MIN. ROCK SIZE D50 = 6" MIN. THICKNESS = 9" UNDERLAY WITH GEOTEXTILE ROCK OUTLET PROTECTION STANDARD EC-1 TYPE A MIN. APRON LENGTH = 10' MIN. UPSTREAM WIDTH = 3.75' MIN. DOWNSTREAM WIDTH = 11.25' MIN. ROCK SIZE D50 = 6" MIN. THICKNESS = 9" UNDERLAY WITH GEOTEXTILE ROCK OUTLET PROTECTION STANDARD EC-1 TYPE A MIN. APRON LENGTH = 16' MIN. UPSTREAM WIDTH = 9' MIN. DOWNSTREAM WIDTH = 12' MIN. ROCK SIZE D50 = 6" MIN. THICKNESS = 9" UNDERLAY WITH GEOTEXTILE PIN 87-A-102A FREDERICK COUNTY SANITATION AUTHORITY INST. 190000230 VA . R O U T E 2 7 7 - F A I R F A X P I K E (6 0 ' R / W ) 15' BUILDING SETBACK 3 5 ' B U I L D I N G S E T B A C K R I G H T O F W A Y P R O P E R T Y L I N E 1 5 ' B U I L D I N G S E T B A C K 51 ' O F 1 5 " 1 5 " C M P @ 0 . 5 0 % C2A C2 6 0 ' O F 2 4 " A D S H P P I P E @ 0 . 6 7 % LIMITS OF DISTURBANCE K: \ P r o j e c t s \ F C S A \ F C S A 1 6 0 5 - L a k e - F r e d e r i c k - E l e v - W a t e r - S t o r a g e \ D E S I G N \ _ P U B L I S H \ S h e e t s \ C S 3 0 0 0 . d w g PL O T T E D : 3/ 2 1 / 2 0 1 9 4 : 3 4 P M , B Y : Da v i d F r a n k PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : PERMIT DRAWINGS CS3000 BY NO . DA T E RE V I S I O N S FCSA1605 1" = 20' TEAM 2019-01-04 DAF/ERS SHEET APPROVED BY OF5 18 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 20'40' PE N N O N I A S S O C I A T E S I N C . 11 7 E a s t P i c c a d i l l y S t r e e t Wi n c h e s t e r , V A 2 2 6 0 1 T 54 0 . 6 6 7 . 2 1 3 9 F 54 0 . 6 6 5 . 0 4 9 3 2/ 2 2 / 2 0 1 9 1 R E V I S E D P E R A G E N C Y C O M M E N T S KL M LA K E F R E D E R I C K E L E V A T E D W A T E R T A N K 18 2 0 F A I R F A X P I K E ST E P H E N S C I T Y V A . P. O . B O X 1 8 7 7 WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 FR E D E R I C K W A T E R SI T E P L A N NORT H DAVID L. FRANK Lic. No.1061 EX . 1 2 ' W A T E R L I N E EX. 12' WATERLINE 10+0 0 10+5 0 11+ 0 0 11+ 5 0 11+ 6 8 5+00 5+50 6+0 0 6+5 0 6+8 2 PR V 254 . 9 9 ' 153.6 3 ' ASP H A L T ACC E S S R O A D ELEVATED STORAGE TANK FFE = 708.00 PR O P O S E D P E - 1 ST A N D A R D P R I V A T E EN T R A N C E 25'R 2 5 ' R FUT U R E S T O R A G E S H E D / OPT I O N A L O U T D O O R S T O R A G E A R E A 3 0 ' 60' 2 20' E M E R . VEH I C L E ACC E S S 2 0 ' E M E R . V E H I C L E A C C E S S 28'R 28 ' R 51 . 2 3 ' ROCK OUTLET PROTECTION STANDARD EC-1 TYPE A MIN. APRON LENGTH = 10' MIN. UPSTREAM WIDTH = 6' MIN. DOWNSTREAM WIDTH = 12' MIN. ROCK SIZE D50 = 6" MIN. THICKNESS = 9" UNDERLAY WITH GEOTEXTILE ROCK OUTLET PROTECTION STANDARD EC-1 TYPE A MIN. APRON LENGTH = 10' MIN. UPSTREAM WIDTH = 3.75' MIN. DOWNSTREAM WIDTH = 11.25' MIN. ROCK SIZE D50 = 6" MIN. THICKNESS = 9" UNDERLAY WITH GEOTEXTILE ROCK OUTLET PROTECTION STANDARD EC-1 TYPE A MIN. APRON LENGTH = 16' MIN. UPSTREAM WIDTH = 9' MIN. DOWNSTREAM WIDTH = 12' MIN. ROCK SIZE D50 = 6" MIN. THICKNESS = 9" UNDERLAY WITH GEOTEXTILE PIN 87-A-102A FREDERICK COUNTY SANITATION AUTHORITY INST. 190000230 VA . R O U T E 2 7 7 - F A I R F A X P I K E (6 0 ' R / W ) 15' BUILDING SETBACK 3 5 ' B U I L D I N G S E T B A C K R I G H T O F W A Y P R O P E R T Y L I N E 1 5 ' B U I L D I N G S E T B A C K 51 ' O F 1 5 " 1 5 " C M P @ 0 . 5 0 % C2A C2 6 0 ' O F 2 4 " A D S H P P I P E @ 0 . 6 7 % 0 + 0 0 0 + 6 5 705.30 705.70 705.20 702.20 INV. 708.00 707.20 707.40 708.00 706.25 707.90 706.40 705.85 706.05 701.80 7 0 2 703 708 705 704 707.00 706.10 705.50 7 0 6 705 704 703 701.5 0 706 705 705 704 704.50 TOP OF BERM 704.50 TOP OF BERM 702 703.85 7 0 2 703 704 704 703 702 704.50 704.50 TOP OF BERM 7 0 4 FLOW LINE 705.79 705.40 705.64 705.16 702.60 702.34 705.50 705.99 705.59705.10 LP 706.14 HP 705.94 706.34 704.90 705.30 703 704.90 701.30701.10 LIMITS OF DISTURBANCE K: \ P r o j e c t s \ F C S A \ F C S A 1 6 0 5 - L a k e - F r e d e r i c k - E l e v - W a t e r - S t o r a g e \ D E S I G N \ _ P U B L I S H \ S h e e t s \ C S 4 0 0 0 . d w g PL O T T E D : 3/ 2 1 / 2 0 1 9 4 : 3 5 P M , B Y : Da v i d F r a n k PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S :   PERMIT DRAWINGS CS4000 BY NO . DA T E RE V I S I O N S FCSA1605 AS NOTED TEAM 2019-01-04 DAF/ERS SHEET APPROVED BY OF6 18 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 20'40' PE N N O N I A S S O C I A T E S I N C . 11 7 E a s t P i c c a d i l l y S t r e e t Wi n c h e s t e r , V A 2 2 6 0 1 T 54 0 . 6 6 7 . 2 1 3 9 F 54 0 . 6 6 5 . 0 4 9 3 2/ 2 2 / 2 0 1 9 1 R E V I S E D P E R A G E N C Y C O M M E N T S KL M                                                  LA K E F R E D E R I C K E L E V A T E D W A T E R T A N K 18 2 0 F A I R F A X P I K E ST E P H E N S C I T Y V A . P. O . B O X 1 8 7 7 WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 FR E D E R I C K W A T E R GR A D I N G P L A N   NORT H DAVID L. FRANK Lic. No.1061   WATERLINE (INLET) HORIZONTAL SCALE: 1" = 20' VERTICAL SCALE: 1" = 4' 690 700 710 690 700 710 WATERLINE (OUTLET) HORIZONTAL SCALE: 1" = 20' VERTICAL SCALE: 1" = 4' 690 700 710 690 700 710 4+75 5+00 70 5 . 6 70 5 . 4 9 70 5 . 8 70 5 . 9 0 5+50 70 5 . 1 70 5 . 3 9 70 4 . 0 70 4 . 8 2 6+00 70 2 . 9 70 5 . 1 4 70 2 . 7 70 5 . 4 0 6+50 70 3 . 1 70 6 . 2 1 70 4 . 4 70 7 . 1 1 7+00 9+75 10+00 70 5 . 5 70 4 . 9 10+50 70 4 . 3 70 4 . 5 7 70 3 . 1 70 5 . 0 4 11+00 70 2 . 6 70 5 . 1 3 70 2 . 7 70 5 . 4 2 11+50 70 3 . 6 70 6 . 7 1 12+00 ELEVATED WATER TANK FFE=708.00 ELEVATED WATER TANK FFE=708.00 18" MIN CLEAR 18" MIN CLEAR EX. 12" PVC WATERLINE 12" DIP CL-52 WATERLINE PROP. 24" ADS HP PIPE INV=701.95 PROP. 24" ADS HP PIPE INV=701.93 12 " 4 5 ° B E N D S T A . 5 + 6 6 . 3 0 12 " T E E S T A . 5 + 1 8 . 3 8 12 " G A T E V A L V E - S T A . 5 + 2 1 . 0 9 12 " T E E S T A . 1 0 + 1 5 . 4 0 12 " G A T E V A L V E - S T A . 1 0 + 1 8 . 3 0 PROP. 12" D I P C L - 5 2 W A T E R L I N E 12 " 2 2 . 5 ° B E N D S T A . 1 0 + 5 2 . 0 7 12 " 4 5 ° B E N D S T A . 1 0 + 6 3 . 9 0 FINISHED GRADE EXISTING GRADE FINISHED GRADE EXISTING GRADE12" MIN. COVER 12" MIN. COVER 12 " 2 2 . 5 ° B E N D S T A . 1 0 + 5 2 . 0 7 12 " 2 2 . 5 ° B E N D S T A . 1 0 + 5 2 . 0 7 FH A S S Y . - S T A . 1 0 + 3 7 . 4 5 EX . 1 2 " G A T E V A L V E - S T A . 5 + 0 3 . 6 0 REMOVE EXISTING 12" PVC WATERLINE FROM GATE VALVE TO PLUG AND REPLACE WITH 12" DIP E X . 1 2 " 4 5 ° B E N D S T A . 5 + 1 3 . 7 0 48' MIN. COVER 48' MIN. COVER CULVERT NO. 2 HORIZONTAL SCALE: 1" = 20' VERTICAL SCALE: 1" = 2' 695 700 695 700 -0+10 0+00 70 2 . 4 70 2 . 4 0 70 3 . 6 70 3 . 6 2 0+80 24" ADS HP PIPE @ 0.67% C2 A F E S 2 4 " IN V 7 0 2 . 2 0 C2 F E S 2 4 " IN V 7 0 1 . 8 0 2X - 12" DIP CL-52 WATERLINE 18 " C L E A R . MI N . EXISTING GRADE FINISHED GRADE K: \ P r o j e c t s \ F C S A \ F C S A 1 6 0 5 - L a k e - F r e d e r i c k - E l e v - W a t e r - S t o r a g e \ D E S I G N \ _ P U B L I S H \ S h e e t s \ C S 4 5 0 0 . d w g PL O T T E D : 3/ 2 1 / 2 0 1 9 4 : 3 5 P M , B Y : Da v i d F r a n k PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : PERMIT DRAWINGS CS4500 BY NO . DA T E RE V I S I O N S FCSA1605 AS NOTED TEAM 2019-01-04 DAF/ERS SHEET APPROVED BY OF7 18 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PE N N O N I A S S O C I A T E S I N C . 11 7 E a s t P i c c a d i l l y S t r e e t Wi n c h e s t e r , V A 2 2 6 0 1 T 54 0 . 6 6 7 . 2 1 3 9 F 54 0 . 6 6 5 . 0 4 9 3 2/ 2 2 / 2 0 1 9 1 R E V I S E D P E R A G E N C Y C O M M E N T S KL M LA K E F R E D E R I C K E L E V A T E D W A T E R T A N K 18 2 0 F A I R F A X P I K E ST E P H E N S C I T Y V A . P. O . B O X 1 8 7 7 WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 FR E D E R I C K W A T E R WA T E R A N D S T O R M P R O F I L E S A N D MI S C E L L A N E O U S D E T A I L S DAVID L. FRANK Lic. No.1061 PRE DEV. DA = 3.99 AC. CN = 77 POST-DEVELOPED IMPERVIOUS AREA = 0.33 AC. POST DEV. DA = 3.99 AC. CN = 78 PIN 8 7 - A - 1 0 2 A FR E D E R I C K C O U N T Y S A N I T A T I O N A U T H O R I T Y IN S T . 1 9 0 0 0 0 2 3 0 V A . R O U T E 2 7 7 - F A I R F A X P I K E ( 6 0 ' R / W ) 15 ' B U I L D I N G S E T B A C K 35 ' B U I L D I N G S E T B A C K RI G H T O F W A Y PROPE R T Y L I N E 15' BUI L D I N G S E T B A C K K: \ P r o j e c t s \ F C S A \ F C S A 1 6 0 5 - L a k e - F r e d e r i c k - E l e v - W a t e r - S t o r a g e \ D E S I G N \ _ P U B L I S H \ S h e e t s \ C S 5 0 0 0 . d w g PL O T T E D : 3/ 2 1 / 2 0 1 9 4 : 3 5 P M , B Y : Da v i d F r a n k PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S :   PERMIT DRAWINGS CS5000 BY NO . DA T E RE V I S I O N S FCSA1605 AS NOTED TEAM 2019-01-04 DAF/ERS SHEET APPROVED BY OF8 18 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PE N N O N I A S S O C I A T E S I N C . 11 7 E a s t P i c c a d i l l y S t r e e t Wi n c h e s t e r , V A 2 2 6 0 1 T 54 0 . 6 6 7 . 2 1 3 9 F 54 0 . 6 6 5 . 0 4 9 3 2/ 2 2 / 2 0 1 9 1 R E V I S E D P E R A G E N C Y C O M M E N T S KL M                                                  LA K E F R E D E R I C K E L E V A T E D W A T E R T A N K 18 2 0 F A I R F A X P I K E ST E P H E N S C I T Y V A . P. O . B O X 1 8 7 7 WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 FR E D E R I C K W A T E R ST O R M W A T E R M A N A G E M E N T D R A I N A G E M A P   NO R T H 00 40'80' DAVID L. FRANK Lic. No.1061   ASP H A L T ACC E S S R O A D ELEVATED STORAGE TANK FFE = 708.00 PR O P O S E D P E - 1 ST A N D A R D P R I V A T E EN T R A N C E SWM POND EX . 1 2 ' W A T E R L I N E EX. 12' WATERLINE PR V 51 ' O F 1 5 " 1 5 " C M P @ 0 . 5 0 % C2A C2 6 0 ' O F 2 4 " A D S H P P I P E @ 0 . 6 7 % 0 + 0 0 0 + 6 5 705.30 705.70 705.20 702.20 INV. 708.00 707.20 707.40 708.00 706.25 706.40 705.85 706.05 701.80 7 0 2 703 705 704 705.50 7 0 6 705 704 703 701.5 0 706 705 705 704 704.50 TOP OF BERM 704.50 TOP OF BERM 702 703.85 7 0 2 703 704 704 703 702 704.50 704.50 TOP OF BERM 7 0 4 FLOW LINE 705.79 705.40 705.64 705.16 702.60 702.34 705.50 705.99 705.59705.10 LP 706.14 HP 705.94 706.34 704.90 705.30 703 704.90 701.30701.10 699.63 700.30 702.55 701.30 15.00' 13.00'1.00'1.00' 3.00'3.00'7.00' 1.42' 8" 702.30 WSE 1 YR.702.58 WSE 2 YR. 703.00 WSE 10 YR. 703.46 WSE 100 YR. 704.50 TOP BANK 16" STONE BASE (21A) COMPACTED SUB BASE WEIR WALL CONTROL STRUCTURE NO SCALE WALL ELEVATION WALL SECTION 8" 24" 16" STONE BASE (21A) COMPACTED SUB BASE 8" #4 REBAR 6" O.C. 12 " #4 REBAR 12" O.C. 6" 3" #4 REBAR 12" O.C. (3) #4 REBAR 6" O.C. 6" TYP. VDOT A3 CONCRETE (TYP.) K: \ P r o j e c t s \ F C S A \ F C S A 1 6 0 5 - L a k e - F r e d e r i c k - E l e v - W a t e r - S t o r a g e \ D E S I G N \ _ P U B L I S H \ S h e e t s \ C S 5 0 0 1 . d w g PL O T T E D : 3/ 2 1 / 2 0 1 9 4 : 3 5 P M , B Y : Da v i d F r a n k PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S :   PERMIT DRAWINGS CS5001 BY NO . DA T E RE V I S I O N S FCSA1605 AS NOTED TEAM 2019-01-04 DAF/ERS SHEET APPROVED BY OF9 18 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PE N N O N I A S S O C I A T E S I N C . 11 7 E a s t P i c c a d i l l y S t r e e t Wi n c h e s t e r , V A 2 2 6 0 1 T 54 0 . 6 6 7 . 2 1 3 9 F 54 0 . 6 6 5 . 0 4 9 3 2/ 2 2 / 2 0 1 9 1 R E V I S E D P E R A G E N C Y C O M M E N T S KL M                                                  LA K E F R E D E R I C K E L E V A T E D W A T E R T A N K 18 2 0 F A I R F A X P I K E ST E P H E N S C I T Y V A . P. O . B O X 1 8 7 7 WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 FR E D E R I C K W A T E R ST O R M W A T E R M A N A G E M E N T D E T A I L S   NORT H 00 20'40' DAVID L. FRANK Lic. No.1061   Sheet: 2 File: K:\Projects\FCSA\FCSA1605-Lake-Frederick-Elev-Water-Storage\ANALYTICAL\CALCULATIONS\Stormwater\SWM\SWM Report 20190219\FCSA1605 Project Description_20190221.pdf Missing or invalid reference LIMITS OF DISTURBANCE PIN 87-A-102A FREDERICK COUNTY SANITATION AUTHORITY INST. 190000230 15' BUILDING SETBACK SF DDLOD LOD SF LOD LOD DD DD OP CIP CIP CE CIP OP VDOT PE-1 SEE CS8500 CD TS TS ROCK OUTLET PROTECTION STANDARD EC-1 TYPE A MIN. APRON LENGTH = 10' MIN. UPSTREAM WIDTH = 6' MIN. DOWNSTREAM WIDTH = 12' MIN. ROCK SIZE D50 = 6" MIN. THICKNESS = 9" UNDERLAY WITH GEOTEXTILE ROCK OUTLET PROTECTION STANDARD EC-1 TYPE A MIN. APRON LENGTH = 10' MIN. UPSTREAM WIDTH = 3.75' MIN. DOWNSTREAM WIDTH = 11.25' MIN. ROCK SIZE D50 = 6" MIN. THICKNESS = 9" UNDERLAY WITH GEOTEXTILE LIMITS OF DISTURBANCE EX . 1 2 ' W A T E R L I N E EX. 12' WATERLINE PR V ASP H A L T ACC E S S R O A D ELEVATED STORAGE TANK FFE = 708.00 PR O P O S E D P E - 1 ST A N D A R D P R I V A T E EN T R A N C E FUT U R E S T O R A G E S H E D / OPT I O N A L O U T D O O R S T O R A G E A R E A SWM POND 2 ROCK OUTLET PROTECTION STANDARD EC-1 TYPE A MIN. APRON LENGTH = 10' MIN. UPSTREAM WIDTH = 6' MIN. DOWNSTREAM WIDTH = 12' MIN. ROCK SIZE D50 = 6" MIN. THICKNESS = 9" UNDERLAY WITH GEOTEXTILE ROCK OUTLET PROTECTION STANDARD EC-1 TYPE A MIN. APRON LENGTH = 10' MIN. UPSTREAM WIDTH = 3.75' MIN. DOWNSTREAM WIDTH = 11.25' MIN. ROCK SIZE D50 = 6" MIN. THICKNESS = 9" UNDERLAY WITH GEOTEXTILE ROCK OUTLET PROTECTION STANDARD EC-1 TYPE A MIN. APRON LENGTH = 16' MIN. UPSTREAM WIDTH = 9' MIN. DOWNSTREAM WIDTH = 12' MIN. ROCK SIZE D50 = 6" MIN. THICKNESS = 9" UNDERLAY WITH GEOTEXTILE FREDERICK COUNTY SANITATION AUTHORITY INST. 190000230 15' BUILDING SETBACK 51 ' O F 1 5 " 1 5 " C M P @ 0 . 5 0 % C2A C2 6 0 ' O F 2 4 " A D S H P P I P E @ 0 . 6 7 % 7 0 2 703 708 705 704 7 0 6 705 704 703 701.5 0 706 705 705 704 702 7 0 2 703 704 704 703 702 7 0 4 FLOW LINE 703 ROCK OUTLET PROTECTION STANDARD EC-1 TYPE A MIN. APRON LENGTH = 10' MIN. UPSTREAM WIDTH = 6' MIN. DOWNSTREAM WIDTH = 12' MIN. ROCK SIZE D50 = 6" MIN. THICKNESS = 9" UNDERLAY WITH GEOTEXTILE ROCK OUTLET PROTECTION STANDARD EC-1 TYPE A MIN. APRON LENGTH = 10' MIN. UPSTREAM WIDTH = 3.75' MIN. DOWNSTREAM WIDTH = 11.25' MIN. ROCK SIZE D50 = 6" MIN. THICKNESS = 9" UNDERLAY WITH GEOTEXTILE SF DDLOD LOD SF LOD LOD OP CIP CIP CE CIP OP PS PS PS B/M B/M B/M B/M B/M PS K: \ P r o j e c t s \ F C S A \ F C S A 1 6 0 5 - L a k e - F r e d e r i c k - E l e v - W a t e r - S t o r a g e \ D E S I G N \ _ P U B L I S H \ S h e e t s \ C S 6 0 0 0 . d w g PL O T T E D : 3/ 2 1 / 2 0 1 9 4 : 3 6 P M , B Y : Da v i d F r a n k PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S :   PERMIT DRAWINGS CS6000 BY NO . DA T E RE V I S I O N S FCSA1605 AS NOTED TEAM 2019-01-04 DAF/ERS SHEET APPROVED BY OF10 18 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 20'40' PE N N O N I A S S O C I A T E S I N C . 11 7 E a s t P i c c a d i l l y S t r e e t Wi n c h e s t e r , V A 2 2 6 0 1 T 54 0 . 6 6 7 . 2 1 3 9 F 54 0 . 6 6 5 . 0 4 9 3 2/ 2 2 / 2 0 1 9 1 R E V I S E D P E R A G E N C Y C O M M E N T S KL M                                                  LA K E F R E D E R I C K E L E V A T E D W A T E R T A N K 18 2 0 F A I R F A X P I K E ST E P H E N S C I T Y V A . P. O . B O X 1 8 7 7 WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 FR E D E R I C K W A T E R ER O S I O N A N D S E D I M E N T C O N T R O L P L A N S   NORT H EROSION AND SEDIMENT CONTROL PLAN PHASE I EROSION AND SEDIMENT CONTROL PLAN PHASE II NOTES: EROSION AND SEDIMENT CONTROL LEGEND DAVID L. FRANK Lic. No.1061   00 20'40' NORT H TS PS K: \ P r o j e c t s \ F C S A \ F C S A 1 6 0 5 - L a k e - F r e d e r i c k - E l e v - W a t e r - S t o r a g e \ D E S I G N \ _ P U B L I S H \ S h e e t s \ C S 6 0 0 1 . d w g PL O T T E D : 3/ 2 1 / 2 0 1 9 4 : 3 6 P M , B Y : Da v i d F r a n k PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S :   PERMIT DRAWINGS CS6001 BY NO . DA T E RE V I S I O N S FCSA1605 AS NOTED TEAM 2019-01-04 DAF/ERS SHEET APPROVED BY OF11 18 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PE N N O N I A S S O C I A T E S I N C . 11 7 E a s t P i c c a d i l l y S t r e e t Wi n c h e s t e r , V A 2 2 6 0 1 T 54 0 . 6 6 7 . 2 1 3 9 F 54 0 . 6 6 5 . 0 4 9 3 2/ 2 2 / 2 0 1 9 1 R E V I S E D P E R A G E N C Y C O M M E N T S KL M                                                  LA K E F R E D E R I C K E L E V A T E D W A T E R T A N K 18 2 0 F A I R F A X P I K E ST E P H E N S C I T Y V A . P. O . B O X 1 8 7 7 WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 FR E D E R I C K W A T E R ER O S I O N A N D S E D I M E N T C O N T R O L DE T A I L S A N D N A R R A T I V E   DAVID L. FRANK Lic. No.1061   K: \ P r o j e c t s \ F C S A \ F C S A 1 6 0 5 - L a k e - F r e d e r i c k - E l e v - W a t e r - S t o r a g e \ D E S I G N \ _ P U B L I S H \ S h e e t s \ C S 6 0 0 2 . d w g PL O T T E D : 3/ 2 1 / 2 0 1 9 4 : 3 7 P M , B Y : Da v i d F r a n k PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S :   PERMIT DRAWINGS CS6002 BY NO . DA T E RE V I S I O N S FCSA1605 AS NOTED TEAM 2019-01-04 DAF/ERS SHEET APPROVED BY OF12 18 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PE N N O N I A S S O C I A T E S I N C . 11 7 E a s t P i c c a d i l l y S t r e e t Wi n c h e s t e r , V A 2 2 6 0 1 T 54 0 . 6 6 7 . 2 1 3 9 F 54 0 . 6 6 5 . 0 4 9 3 2/ 2 2 / 2 0 1 9 1 R E V I S E D P E R A G E N C Y C O M M E N T S KL M                                                  LA K E F R E D E R I C K E L E V A T E D W A T E R T A N K 18 2 0 F A I R F A X P I K E ST E P H E N S C I T Y V A . P. O . B O X 1 8 7 7 WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 FR E D E R I C K W A T E R ER O S I O N A N D S E D I M E N T C O N T R O L DE T A I L S   DAVID L. FRANK Lic. No.1061   K: \ P r o j e c t s \ F C S A \ F C S A 1 6 0 5 - L a k e - F r e d e r i c k - E l e v - W a t e r - S t o r a g e \ D E S I G N \ _ P U B L I S H \ S h e e t s \ C S 7 0 0 0 . d w g PL O T T E D : 3/ 2 1 / 2 0 1 9 4 : 3 7 P M , B Y : Da v i d F r a n k PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S :   PERMIT DRAWINGS CS7000 BY NO . DA T E RE V I S I O N S FCSA1605 AS NOTED TEAM 2019-01-04 DAF/ERS SHEET APPROVED BY OF13 18 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PE N N O N I A S S O C I A T E S I N C . 11 7 E a s t P i c c a d i l l y S t r e e t Wi n c h e s t e r , V A 2 2 6 0 1 T 54 0 . 6 6 7 . 2 1 3 9 F 54 0 . 6 6 5 . 0 4 9 3 2/ 2 2 / 2 0 1 9 1 R E V I S E D P E R A G E N C Y C O M M E N T S KL M                                                  LA K E F R E D E R I C K E L E V A T E D W A T E R T A N K 18 2 0 F A I R F A X P I K E ST E P H E N S C I T Y V A . P. O . B O X 1 8 7 7 WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 FR E D E R I C K W A T E R FR E D E R I C K W A T E R D E T A I L S   DAVID L. FRANK Lic. No.1061   (8" AND 3" Cla-Val model 990-01) HANDICAP SIGN DETAIL NOT TO SCALE CONCRETE WHEEL STOP SCALE: NTS 2% SLOPE HANDICAP SIGN DETAIL NOT TO SCALE CONCRETE WHEEL STOP SCALE: NTS 2% SLOPE ENTRANCE PROFILE HORIZONTAL SCALE: 1" = 20' VERTICAL SCALE: 1" = 2' 700 710 700 710 0+00 70 4 . 9 70 5 . 7 70 5 . 7 6 1+00 -2.00%2.00% 1. 6 8 ' 0+ 5 1 . 7 6 R I G H T O F W A Y L I N E 0+ 2 7 . 0 0 F L O W L I N E 0+ 1 2 . 0 0 E X . E P EXISTING GRADE FINISHED GRADE PVI STA = 0+27 PVI ELEV = 705.30 A.D. = +4.00 K = 5.00 BV C S : 0 + 1 7 BV C E : 7 0 5 . 5 0 EV C S : 0 + 3 7 EV C E : 7 0 5 . 5 0 LOW POINT ELEV = 705.40 LOW POINT STA = 0+27 20' VC STA:0+51.76 ELEV:705.79 STA:0+27.00 ELEV:705.40 A S P H A L T A C C E S S R O A D E L E V A T E D S T O R A G E T A N K F F E = 7 0 8 . 0 0 P R O P O S E D P E - 1 S T A N D A R D P R I V A T E E N T R A N C E 2 5 ' R 25'R S W M P O N D 2 8 ' R 3 ' 2 1 A S T O N E ( T Y P . ) R O C K O U T L E T P R O T E C T I O N S T A N D A R D E C - 1 T Y P E A M I N . A P R O N L E N G T H = 1 0 ' M I N . U P S T R E A M W I D T H = 6 ' M I N . D O W N S T R E A M W I D T H = 1 2 ' M I N . R O C K S I Z E D 5 0 = 6 " M I N . T H I C K N E S S = 9 " U N D E R L A Y W I T H G E O T E X T I L E R O C K O U T L E T P R O T E C T I O N S T A N D A R D E C - 1 T Y P E A M I N . A P R O N L E N G T H = 1 0 ' M I N . U P S T R E A M W I D T H = 3 . 7 5 ' M I N . D O W N S T R E A M W I D T H = 1 1 . 2 5 ' M I N . R O C K S I Z E D 5 0 = 6 " M I N . T H I C K N E S S = 9 " U N D E R L A Y W I T H G E O T E X T I L E R O C K O U T L E T P R O T E C T I O N S T A N D A R D E C - 1 T Y P E A M I N . A P R O N L E N G T H = 1 6 ' M I N . U P S T R E A M W I D T H = 9 ' M I N . D O W N S T R E A M W I D T H = 1 2 ' M I N . R O C K S I Z E D 5 0 = 6 " M I N . T H I C K N E S S = 9 " U N D E R L A Y W I T H G E O T E X T I L E V A . R O U T E 2 7 7 - F A I R F A X P I K E ( 6 0 ' R / W ) 35' BUILDING SETBACK RIGHT OF WAY 702 7 0 3 7 0 8 7 0 5 7 0 4 706 7 0 5 7 0 4 7 0 3 7 0 1 . 5 0 7 0 6 70 5 7 0 5 704 7 0 2 702 7 0 3 7 0 4 7 0 4 7 0 3 7 0 2 704 F L O W L I N E 7 0 3 LINE OF SIGHT A LINE OF SIGHT B SIGHT DISTANCE RIGHT 610' SIGHT DISTANCE LEFT 610' E X . 1 2 ' W A T E R L I N E E X . 1 2 ' W A T E R L I N E P R V 12 " X 8 " T E E ( N O T E : 1 2 " 9 0 ° M J V E R T . B E N D B E L O W S L A B ) 8" G . V . ( T Y P ) O N I N L E T L I N E 8" M A G . F L O W M E T E R ( N I C ) 8 " A L T I T U D E V A L V E CL A - V A L M O D E L 2 1 0 - 0 3 8 " G A T E V A L V E O N 8 " I N L E T B Y P A S S L I N E (N O T E : T H E B Y - P A S S P I P I N G S H A L L B E I N S T A L L E D DI R E C T L Y A B O V E T H E P R I M A R Y I N L E T P I P I N G ) 1 2 " 9 0 ° B A S E E L B O W A T B O T T O M O F 12 " I N L E T R I S E R P I P E 12 " M A G . F L O W M E T E R ( N I C ) 12 " 9 0 ° B A S E E L B O W A T B O T T O M O F 12 " O U T L E T R I S E R P I P E 1 2 " 9 0 ° B A S E E L B O W A T B O T T O M O F 12 " O V E R F L O W R I S E R P I P E 4 " D R A I N L I N E A N D G V B E T W E E N OU T L E T A N D O V E R F L O W R I S E R S OV E R F L O W O U T L E T 2" G . V . ( T Y P . ) O N 2 " LO W - F L O W B Y P A S S L I N E 2" M A G . F L O W M E T E R ( N I C ) 2 " C H E C K V A L V E 12 " G . V . ( T Y P . ) O N O U T L E T L I N E 12 " G . V . O N 1 2 " O U T L E T B Y P A S S L I N E 12 " 9 0 ° B E N D (N O T E : 1 2 " 9 0 ° M J V E R T . B E N D B E L O W S L A B ) 1 2 " D I P C L - 5 2 W A T E R L I N E ( O U T L E T ) 1 2 " D I P C L - 5 2 W A T E R L I N E ( I N L E T ) E L E V A T E D S T O R A G E T A N K F F E = 7 0 8 . 0 0 O V E R F L O W / D R A I N S T R U C T U R E 12 " O V E R F L O W / DR A I N P I P E 12 " C H E C K V A L V E K: \ P r o j e c t s \ F C S A \ F C S A 1 6 0 5 - L a k e - F r e d e r i c k - E l e v - W a t e r - S t o r a g e \ D E S I G N \ _ P U B L I S H \ S h e e t s \ C S 8 5 0 0 . d w g PL O T T E D : 3/ 2 1 / 2 0 1 9 4 : 3 7 P M , B Y : Da v i d F r a n k PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : PERMIT DRAWINGS CS8500 BY NO . DA T E RE V I S I O N S FCSA1605 AS NOTED TEAM 2019-01-04 DAF/ERS SHEET APPROVED BY OF14 18 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PE N N O N I A S S O C I A T E S I N C . 11 7 E a s t P i c c a d i l l y S t r e e t Wi n c h e s t e r , V A 2 2 6 0 1 T 54 0 . 6 6 7 . 2 1 3 9 F 54 0 . 6 6 5 . 0 4 9 3 2/ 2 2 / 2 0 1 9 1 R E V I S E D P E R A G E N C Y C O M M E N T S KL M LA K E F R E D E R I C K E L E V A T E D W A T E R T A N K 18 2 0 F A I R F A X P I K E ST E P H E N S C I T Y V A . P. O . B O X 1 8 7 7 WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 FR E D E R I C K W A T E R SI T E D E T A I L S A N D S I G H T D I S T A N C E DAVID L. FRANK Lic. No.1061 00 50'100' N O R T H SIGHT DISTANCE SCALE: 1" = 50' 12"X8" TEE ( NOTE: 12" 90° MJ VERT. BEND BELOW SLAB) 8" G.V. (TYP) ON INLET LINE 8" MAG. FLOW METER (NIC) 8" ALTITUDE VALVE CLA-VAL MODEL 210-03 8" GATE VALVE ON 8" INLET BYPASS LINE (NOTE: THE BY-PASS PIPING SHALL BE INSTALLED DIRECTLY ABOVE THE PRIMARY INLET PIPING) 12" 90° BASE ELBOW AT BOTTOM OF 12" INLET RISER PIPE 12" MAG. FLOW METER (NIC) 12" 90° BASE ELBOW AT BOTTOM OF 12" OUTLET RISER PIPE 12" 90° BASE ELBOW AT BOTTOM OF 12" OVERFLOW RISER PIPE 4" DRAIN LINE AND GV BETWEEN OUTLET AND OVERFLOW RISERS OVERFLOW OUTLET 2" G.V. (TYP.) ON 2" LOW-FLOW BYPASS LINE 2" MAG. FLOW METER (NIC) 2" CHECK VALVE 12" G.V. (TYP.) ON OUTLET LINE 12" G.V. ON 12" OUTLET BYPASS LINE 12" 90° BEND (NOTE: 12" 90° MJ VERT. BEND BELOW SLAB) 12" D I P C L - 5 2 W A T E R L I N E ( O U T L E T ) 12" D I P C L - 5 2 W A T E R L I N E ( I N L E T ) ELEVATED STORAGE TANK FFE = 708.00 OVERFLOW / DRAIN STRUCTURE 12" OVERFLOW / DRAIN PIPE 12" CHECK VALVE K: \ P r o j e c t s \ F C S A \ F C S A 1 6 0 5 - L a k e - F r e d e r i c k - E l e v - W a t e r - S t o r a g e \ D E S I G N \ _ P U B L I S H \ S h e e t s \ C U 7 5 0 0 . d w g PL O T T E D : 3/ 2 1 / 2 0 1 9 4 : 3 8 P M , B Y : Da v i d F r a n k PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S : PERMIT DRAWINGS CU7500 BY NO . DA T E RE V I S I O N S FCSA1605 AS NOTED TEAM 2019-01-04 DAF/ERS SHEET APPROVED BY OF15 18 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PE N N O N I A S S O C I A T E S I N C . 11 7 E a s t P i c c a d i l l y S t r e e t Wi n c h e s t e r , V A 2 2 6 0 1 T 54 0 . 6 6 7 . 2 1 3 9 F 54 0 . 6 6 5 . 0 4 9 3 2/ 2 2 / 2 0 1 9 1 R E V I S E D P E R A G E N C Y C O M M E N T S KL M LA K E F R E D E R I C K E L E V A T E D W A T E R T A N K 18 2 0 F A I R F A X P I K E ST E P H E N S C I T Y V A . P. O . B O X 1 8 7 7 WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 FR E D E R I C K W A T E R WA T E R T A N K M I S C E L L A N E O U S D E T A I L S 12VAC5-590-800. Disinfection. All pipes, tanks, and equipment which can convey or store potable water shall be disinfected prior to being placed in service. Plans and specifications shall outline the procedures and include the disinfectant dosage, contact time, and method of testing the results of the procedure. 1. Forms of chlorine for disinfection. a. Liquid chlorine. The use of liquid chlorine shall be acceptable only when suitable equipment is available and only under the direction of a person trained to handle liquid chlorine. Emergency handling equipment shall be provided. It will normally require 4.2 lbs. of liquid chlorine (supplied under pressure in steel containers) to produce a concentration of 50 mg/L of available chlorine in 10,000 gallons of water. b. Calcium hypochlorite. Granular and tablet forms are available (both with 65% available chlorine). It will normally require 6.5 lbs. of calcium hypochlorite to produce a concentration of 50 mg/L of available chlorine in 10,000 gallons of water. c. Sodium hypochlorite. This is supplied in strengths of 5.25% to 16% available chlorine. The required amount of sodium hypochlorite to produce a 50 mg/L concentration of available chlorine in 10,000 gallons of water can be calculated from the following formula: ____50____ % available chlorine 2. Methods of disinfection other than chlorination may be considered by the division on a case-by-case basis. 3. Testing of water following disinfection: a. All chlorine residual determinations shall be made using only those methods approved by the division; and b. Two water samples for bacteriological analysis must be collected at least 24 hours apart and analyzed by a certified laboratory. The results of these samples must indicate no coliform contamination before the pipe, tanks, or equipment can be utilized as part of the waterworks. If contamination is indicated, then the disinfection procedure must be repeated. 12VAC5-590-1080. General. N. All finished water storage facilities shall be cleaned to remove all dirt and loose materials prior to disinfection of the structure. Only potable water shall be used to clean and rinse the water storage facilities. All equipment including brooms, brushes, spray equipment and workmen's boots shall be disinfected before they are used to clean the storage facilities. O. All finished water storage facilities shall be satisfactorily disinfected prior to being placed in operation. The disinfection of the storage facilities shall be repeated until it is determined, by bacteriological testing, that the water is free of coliform bacteria. 1. One of the following disinfection methods shall be used. Other methods of disinfection may be approved on a case-by-case basis by the division. a. The tank shall be filled to the overflow level with potable water to which enough chlorine has been added to produce an initial chlorine concentration of 50 mg/L in the full tank. The full tank should stand for 24 hours; however, in no case shall it stand less than six hours. At the end of the holding period, the chlorinated water shall be drained to waste, the tank refilled with potable water, and tested for satisfactory bacteriological quality before placing the tank in service. b. All interior surfaces of the tank shall have applied a chlorine solution containing at least 200 mg/L of free available chlorine. The chlorine solution shall be applied with either spray equipment or brushes. Any equipment used to apply the chlorine solution shall either be new or previously used only for disinfection purposes. The chlorine solution shall remain in contact with the tank surfaces for at least 30 minutes. The tank shall then be filled with potable water to the overflow level and tested for satisfactory bacteriological quality before placing the tank in service; or c. Potable water containing a free chlorine residual of 50 mg/L shall be placed in the tank to such a depth that when the tank is filled, the resulting chlorine concentration in the water will be at least two mg/L. The water containing 50 mg/L of chlorine shall stand in the tank for 24 hours. The tank shall then be filled with potable water and allowed to stand for 24 additional hours. At the end of the second 24 hour period, the chlorine residual shall be at least two mg/L. After analyses of the water for satisfactory bacteriological quality, the tank may be placed in service without draining the water used to disinfect it. 2. Testing of the water following disinfection shall be in accordance with 12VAC5-590-800 K: \ P r o j e c t s \ F C S A \ F C S A 1 6 0 5 - L a k e - F r e d e r i c k - E l e v - W a t e r - S t o r a g e \ D E S I G N \ _ P U B L I S H \ S h e e t s \ C U 7 5 0 1 . d w g PL O T T E D : 3/ 2 1 / 2 0 1 9 4 : 3 8 P M , B Y : Da v i d F r a n k PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S :   PERMIT DRAWINGS CU7501 BY NO . DA T E RE V I S I O N S FCSA1605 AS NOTED TEAM 2019-01-04 DAF/ERS SHEET APPROVED BY OF16 18 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PE N N O N I A S S O C I A T E S I N C . 11 7 E a s t P i c c a d i l l y S t r e e t Wi n c h e s t e r , V A 2 2 6 0 1 T 54 0 . 6 6 7 . 2 1 3 9 F 54 0 . 6 6 5 . 0 4 9 3 2/ 2 2 / 2 0 1 9 1 R E V I S E D P E R A G E N C Y C O M M E N T S KL M                                                  LA K E F R E D E R I C K E L E V A T E D W A T E R T A N K 18 2 0 F A I R F A X P I K E ST E P H E N S C I T Y V A . P. O . B O X 1 8 7 7 WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 FR E D E R I C K W A T E R WA T E R T A N K M I S C E L L A N E O U S D E T A I L S   NOT TO SCALE 1 2 3" CRUSHED ROCK BACKFILL GRAY & BENTONITE SEAL STRIPS. APPLY AS OUTLINED IN THE BUILDERS GUIDE. FOR FOUNDATION CONCRETE REINFORCEMENT STEEL REFER TO THE PROJECT SUBMITTAL DOCUMENTATION. 12" 18.0" 6'-0" OR LESS PIPE PENETRATION CONCRETE PROFILE AT TOP OF FOOTING FOOTING O.D. TANK FOUNDATION SHEET FOOTING I.D. TOP OF FOOTING FLOOR REBAR THIS IS A TYPICAL PIPE PENETRATION DETAIL THROUGH THE FOUNDATION FLOOR WHEN THE PIPE IS LOCATED 6'-0" OR LESS FROM THE TANK INSIDE WALL. TYPICAL FOR 8" INLET PIPE. FLANGED 90° BEND 6"   K: \ P r o j e c t s \ F C S A \ F C S A 1 6 0 5 - L a k e - F r e d e r i c k - E l e v - W a t e r - S t o r a g e \ D E S I G N \ _ P U B L I S H \ S h e e t s \ C U 7 5 0 2 . d w g PL O T T E D : 3/ 2 1 / 2 0 1 9 4 : 3 8 P M , B Y : Da v i d F r a n k PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S :   PERMIT DRAWINGS CU7502 BY NO . DA T E RE V I S I O N S FCSA1605 AS NOTED TEAM 2019-01-04 DAF/ERS SHEET APPROVED BY OF17 18 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PE N N O N I A S S O C I A T E S I N C . 11 7 E a s t P i c c a d i l l y S t r e e t Wi n c h e s t e r , V A 2 2 6 0 1 T 54 0 . 6 6 7 . 2 1 3 9 F 54 0 . 6 6 5 . 0 4 9 3 2/ 2 2 / 2 0 1 9 1 R E V I S E D P E R A G E N C Y C O M M E N T S KL M                                                  LA K E F R E D E R I C K E L E V A T E D W A T E R T A N K 18 2 0 F A I R F A X P I K E ST E P H E N S C I T Y V A . P. O . B O X 1 8 7 7 WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 FR E D E R I C K W A T E R WA T E R T A N K M I S C E L L A N E O U S D E T A I L S     EX . 1 2 ' W A T E R L I N E EX. 12' WATERLINE 5+00 5+50 6+0 0 6+5 0 6+8 2 PR V ELEVATED STORAGE TANK FFE = 708.00 FUT U R E S T O R A G E S H E D / OPT I O N A L O U T D O O R S T O R A G E A R E A SWM POND 2 20' E M E R . VEH I C L E ACC E S S 2 0 ' E M E R . V E H I C L E A C C E S S 3' 21A STONE (TYP.) 3' 21A STONE (TYP.) ROCK OUTLET PROTECTION STANDARD EC-1 TYPE A MIN. APRON LENGTH = 10' MIN. UPSTREAM WIDTH = 6' MIN. DOWNSTREAM WIDTH = 12' MIN. ROCK SIZE D50 = 6" MIN. THICKNESS = 9" UNDERLAY WITH GEOTEXTILE ROCK OUTLET PROTECTION STANDARD EC-1 TYPE A MIN. APRON LENGTH = 10' MIN. UPSTREAM WIDTH = 3.75' MIN. DOWNSTREAM WIDTH = 11.25' MIN. ROCK SIZE D MIN. THICKNESS = 9" UNDERLAY WITH GEOTEXTILE ROCK OUTLET PROTECTION STANDARD EC-1 TYPE A MIN. APRON LENGTH = 16' MIN. UPSTREAM WIDTH = 9' MIN. DOWNSTREAM WIDTH = 12' MIN. ROCK SIZE D50 = 6" MIN. THICKNESS = 9" UNDERLAY WITH GEOTEXTILE PIN 87-A-102A FREDERICK COUNTY SANITATION AUTHORITY INST. 190000230 15' BUILDING SETBACK LIMITS OF DISTURBANCE 7 0 2 703 708 705 704 7 0 6 705 704 703 701.5 0 706 705 705 704 702 7 0 2 703 704 704 703 702 7 0 4 FLOW LINE 703 K: \ P r o j e c t s \ F C S A \ F C S A 1 6 0 5 - L a k e - F r e d e r i c k - E l e v - W a t e r - S t o r a g e \ D E S I G N \ _ P U B L I S H \ S h e e t s \ C S 9 0 0 0 . d w g PL O T T E D : 3/ 2 1 / 2 0 1 9 4 : 3 9 P M , B Y : Da v i d F r a n k PL O T S T Y L E : Pe n n o n i N C S . s t b PR O J E C T S T A T U S :   PERMIT DRAWINGS CS9000 BY NO . DA T E RE V I S I O N S FCSA1605 AS NOTED CJM/KVS 2018-12-21 ERS SHEET APPROVED BY OF18 18 DRAWN BY DRAWING SCALE DATE PROJECT ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 20'40' PE N N O N I A S S O C I A T E S I N C . 11 7 E a s t P i c c a d i l l y S t r e e t Wi n c h e s t e r , V A 2 2 6 0 1 T 54 0 . 6 6 7 . 2 1 3 9 F 54 0 . 6 6 5 . 0 4 9 3 2/ 2 2 / 2 0 1 9 1 R E V I S E D P E R A G E N C Y C O M M E N T S KL M                                                  LA K E F R E D E R I C K E L E V A T E D W A T E R T A N K 18 2 0 F A I R F A X P I K E ST E P H E N S C I T Y V A . P. O . B O X 1 8 7 7 WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 FR E D E R I C K W A T E R LA N D S C A P E P L A N , N O T E S , A N D D E T A I L S -- - - NORT H DAVID L. FRANK Lic. No.1061   TREE PLANTING TYPICAL MULCH EDGING DETAIL GENERAL CONDITIONS: MAINTENANCE OF LANDSCAPING NOTES: PARKING LOT LANDSCAPE CALCULATIONS:GENERAL PLANT LIST GENERAL LANDSCAPING NOTES: