HomeMy WebLinkAbout44-18 CommentsFrederick C'vurrtl,
Departnm,-w of Fire acrd Rescue
Office of the Fire Marshal
1080 Curers -tone Drite Y hirhrs/er, V/1 22602
(.540) 665-6350 Fa.i: (540) 678-,1'7.39 LYnaih fir:crra_fcva.us
Dale Received
1 9 11 612 01 8
PlanlPerrrit Type Site Plan 11-16-18
Name TSM-Welltown
Address Welltown Rd/McGhee Rd
Pro ect Name
Applicant Name & Number
RE#
Permit Number
Winchester
Site Plan 11-16-18
GreyWolfe, Inc. 540-667-2001
Emergency Vehicle Access: Adeiate Inadeglaate N/A
Hydrant Location' Ad
t(uate Inadequate NIA
Siamese Location:
Adec'uate
Inadequate
NIA
Fire Lanes Required-
Yom`
No
NIA
Plan Approval Status
Approve
Comments
Areas hi -lighted iii orange shall have No Parking Fire Lane signs Installed
Areas hi -lighted In yellow shall be striped in yellow
F
Signature:
Reviewed By: Kenneth Scott, Jr.
Title::
Date Reviewed
1 211 312 01 8
VA 22603
REQUEST FOR SITE PLAN COMMENTS
Frederick Cotanty Inspections
Department Comment
Mail to:
Frederick County Inspections Department
Attn: Building Official
107 North Kent Street
Winchester, Virginia 22601
3', OpPM an I I ,1 ,-!
Hand deliver to:
Frederick County Inspections Dept.
107 North Kent Street, 2"d Floor
Winchester, Virginia 22601
Phone: (540) 665-5650
Applicant: It is your responsibility to complete this form as accurately as possible in order to assist the agency with their
review. Please attach two (2) copies of the Site Plan with this sheet.
Applicant's Name: GreyWolfe, Inc. - Gary R. 0ates,LS-l3,PE Telephone: (540) 667-2001
Email Address: GreyWolfelnc@aol.com
Mailing Address: 1073 Redbud Road, Winchester, VA 22603
Name of development and description of the request:
TSM-Welltown
Location of Property:
Intersection of Welftown Road (Route 661) and McGhee Road (Route 861)
Department Comments:
-FREDERICK COUNTY INSPECTIONS DEPARTMENT USE ONLY-
[
Date Received L? Review Numbera2 `� 4 5 (circle one)
Date Reviewed 1 9 ... ) f 2, 9
Revision Required / tJ O Da Approved Z_ I A
Signature &Date:
** Please Return Form to Applicant"
18
Buildings shall comply with The Virginia Uniform Statewide Building Code and Sections 311, S
Storage) and Section 304, B -Business of the International Building Code/2015. Other Code that
applies are the Virginia Mechanical Code for air change, the ICC ANSI Al 17.1-3-09 Accessible
and Usable Buildings and Facilities, 2015 Virginia Energy Code and 2015 International Fire
Code.
Building shall comply with height and area as allowed per T503 with the applicable increases.
Building shall comply with IBC/USBC 903.2.9 for sprinkler requirements.
Group S-1 fire areas used for the storage of commercial trucks where the fire area exceed 5000
sq ft, as well as, S-1 fire areas in excess of S,OOOK sq ft and used for commercial truck repair
garage shall be provided with an NFPA sprinkler system
Quantity of hazardous material quantities and limitations shall be as required/limited under
T307.1(1) to prevent the structure from falling into an H Hazardous use group
Building is fully sprinklered as required.
Question to the location of the water oil separator.
At least one parking area is required to be a Van Accessible space as required in USBC Sec
1106. Accessible parking and unloading requires a minimum of 8' parking, and a minimum of
8' of striped unloading area. Unloading area shall have a maximum 2% slope. Vanaccessible
signage is provided as required per USBC Sec 1106.8.
Accessible route to main entrance shall not exceed 5% (1:20) slope. At least 60% of all
entrances shall be accessible. Landings at doors shall not exceed 1:48 slope and thresholds shall
not exceed ''/Z". Please provide elevations at all four comers of the parking/unloading and all.
All required exits shall be accessible and meet the requirements of VBC Section 1007.
Question on exit location and the slope of the apron.
Building shall comply with 2015 International Energy Code. All systems shall be included in the
evaluation of the building performance. Vestible area meeting ANSI A] 17.1-09 is required
when entrance door enters into 3000 sq ft of floor space.
All structural plans submitted for permit application shall be sealed by a VA Design Professional.
Please note the requirements in Chapter 17 of the IBC for special inspections for this type of
structure.(soil, concrete, bolts, etc.)
1/29 oil separator noted outside the building, accessible parking/unloading and access to main
entrance appears to meet ANSI Al 17.1-09
s:lsiteplan comments\2015\s-1 storage; commercial vehicles.doc
FREDERICK FREDERICK WATER
L
WATER SITE PLAN REVIEWCO-NINIENTS
PO Box 1877, Winchester, VA 22604-8377 540.868.1061 voice
315 Tasker Road, Stephens City, VA 22655 540.868.1429 fax
Project �, y 1 G��ri
Applicant 6r w d —1 ed '
REVIEW STATUS attention moe. 6 I Y DO/ [ �
review number
correct & resubmit approved as noted number of items to be corrected
approved
DRAWINGS
send me by Ilihi
1. print of sheets 0 6 _
2. two CDs: each disc shall contain the following plan sheets, i
a) One CD (containing all of the above noted sheets) shall be in PDF format. Each sheet shall be in its
own file and be in landscape orientation. Each file shall be titled with the project name and appropriate
sheet number.
b) One CD shall be in DWG format; (1) in Model Space, (2) instate plane coordinate system NAD 83,(3)
compatible with AutoCAD 2006.
C) Each of the two CDs shall be labeled with its format and project name, and placed in its own paper CD
envelope.
EASEMENTS
tr Y// N A copy of the recorded onsite FW easement(s) is/are required.
Y/eA copy of the recorded offsite FW easement(s) is/are required.
The easement document shall contain a plat and both shall be signed by the Frederick Water.
o The Frederick Water requires specific language in its deed of easement.
o Visit our website www.frederickwater.com to obtain a copy of the form.
o A copy of the recorded deed(s) of easement shall be received before service will be authorized.
OTHER
Y / This project also requires DEQ - Valley Region Office approval.
Y This project also requires VDH — Lexington Field Office approval.
N This project also requires VDH — Lexington Field Office — Project Summary Report. BY DATE FOR
DRAWINGS ABOVE, see VDH website for form
Y//N
/O
This project has a sewer pump station that FW will own. Title to the pump station site shall be granted
(,/ to the Frederick Water in fee simple absolute. Also, (1) a copy of DEQ's Certificate to Construct, (2) a
copy of DEQ's Certificate to Operate, and (3) two copies of the FW approved O & M manual are
required. These documents must be received before service will be authorized. (4) Work cannot
commence that would connect to FW facilities or require FW inspections until the contract is returned
to this office.
Date: �/01 1 f®�
Karl W. Wiley—..E'ngroeering assistant DTT ' I IN
Subject:
RE: TSM - Revised Entrance Sheets
Date:
1/24/2019 11:03:31 AM Eastern Standard Time
From:
timothy.rhodes@vdot.virginia.gov
To:
greywolfeinc@aol.com
Cc:
rhonda.funkhouser@vdot.virginia.gov
Gary,
The only thing I see that needs changed is on Sheet 2. Please show the Welltown entrance as 24', not 34, like it
is presented on sheet 9. Other than that, all looks well.
Thanks,
771mothy Rhodes
VDOT—Land Development Engineer
Clarke, Frederick, Shenandoah & Warren Counties
14031 Old Valley Pike
Edinburg, VA. 22824
(540)-984-5630
From: Greywolfe [mailto:grgywolfeinc@aol.com
Sent: Thursday, January 24, 2019 8:19 AM
To: timothyrhodes@vdot.virginia.gov
Subject: TSM - Revised Entrance Sheets
See attached.
Thank you,
Gary R. Oates, LS -B, PE
1073 Red Bud Road
Winchester, Virginia 22603
(540) 667-2001
"Opportunity is missed by most people because it comes dressed in overalls and looks like work." -- Thomas Edison
CO NIT Y of Fi REDJ-C K
Dep;arti ie;nt of Public Work
5401665-5643
FAX: 540/578-0682
February 11, 2019
Mr. Gary Oates, LS -B, PE
GreyWolfe, Inc.
1073 Redbud Road
Winchester, Virginia 22603
RE: Revised Site Plan Comments — TSM-Welltown
Dear Mr. Oates:
Upon review of the revised site plan dated January 11, 2019, we recommend approval of
the subject plan.
Joseph W. Johnson, P.E.
Civil Engineer
JCW/kco
cc: Planning and Development
file
Sincerely,
Joe C. Wilder
Director of Public Works