Loading...
HomeMy WebLinkAbout18-18 CommentsRECEIVED'' REQUEST FOR SITE PLAN COMMENTS SEP 2 4 tot Frederick County Frederick COUnty 1nspe BlVorks & Inspections Department Comment Mail to: Band deliver to: Frederick County Inspections Department Frederick County Inspections Dept. Attn: Building Official 107 North Kent Street, 2nd Floor 107 North Kent Street Winchester, Virginia 22601 Winchester, Virginia 22601 Phone: (540) 665-5650 Applicant: It is your responsibility to complete this form as accurately as possible in order to assist the agency with their review. Please attach two:Q eotlies_of the.Site Plan with this sheet Applicants Name: PAINTER-LEWIS, P.L.C. Email Address: office@painterlewis.com Mailing Address: 817 CEDAR CREEK GRADE SUITE 120 WINCHESTER, VA 22601 Name of development and description of the request: H. N. FUNKHOUSER, CLEAR BROOK SHELL SITE PLAN REVIEW Telephone: 540-662-5792 Location of Property: SE CORNER OF THE INTERSECTION OF ROUTE 11 AND BUSINESS BOULEVARD ions Department Comments: -FREDERICK COUNTY INSPECTIONS DEPARTMENT USE ONLY - Date Received 9 L 1 ®-9/ig- Review Number2 4 5 (circle one) Date Reviewed /,V// , 011,9 '" Revision Required �� Date Approved j1C)jj all Signature & Date: �* Please Return F6rm-to. Applicant��; . . 18 Building shall comply with The Virginia Uniform Statewide Building Code and section 309, use group M (Mercantile) Virginia Building Code/2015. Other codes that apply are ICC/ ANSI A 117.1-2009 Accessible and Usable Buildings and Facilities, National Fire Protection Agency 30 and International Fire Code 2015. New M -Mercantile Building shall meet height and area per T503 with allowable increases. Building plans submitted for permitting for proposed canopy shall be designed by a registered design professional licensed in the state of Virginia. Installation of gas fueling equipment and fuel storage tanks shall be in accordance with the International Fire Code 2015 & NPFA 30. Emergency fuel shut off is required within 100' of fueling station. Question on the location ofgrease interceptor Handicap parking shall comply with ANSI A117.1-09. Van accessible parking shall have a minimum of 11' width with 5' unloading area or a minimum of 8' unloading area with an 8' width. Maximum 2% slope required for parking and unloading. Please note the requirements in Chapter 17 of VBC for special inspection requirements on the type of structure (Soils, concrete etc.) Geotech report is required. Signs require a building permit, as well as awnings attached to the new store. Engineer design required for canopy signage and awnings. 10/18 two emergency fuel shutoffs located at each end of the building with 100' of fueling as required Grease trap is inside the building S:\Site Plan comments\2015\N4erchantile and gas H N Funk.doc Frederick County Department of Fire and Fescue Office of the Fire Marshal WHO Coverstone Drlti ,° 1 Wychester. VA 226112 (540) 665-64356 F'kv (541) 678-473Y Einai1: fig o6Dfcva.u.s Plan Review & Comments Date Received Date Reviewed 912412018 101312018 Plan/Perrmt Type Site Plan 09-24-18 Name Clear Brook Shell Address Rt. 11113usiness Blvd. Clear Brook VA 22624 Project Mame New Construction Applicant Name & Number Painter -Lewis 540-662-5792 RE# Permit Number Emergency Vehicle Access, Ad64uate Inadequate NIA Hydrant Location. Adequate Inadequate NIA Siamese Location. Adequate Inadequate N;k \ Fire Lanes Required: Yes No N/A Pian Approval Status Approve Comments Areas hi -lighted In yellow shall be strip€sd in yellow Areas hl -lighted In orange shall have No Padding Fire Lane signs Installed i 1Y1 Signature Reviewed By: Kenneth Scats. Jr. r { r T tle C013NTY of FREDERICK Dopa. tem ew. of E'ublic'Arcirks 540' !66S ­_z643 November 29, 2018 Mr. John C. Lewis Painter -Lewis, P.L.C. 817 Cedar Creek Grade Winchester, Virginia 22601 RE: Revised Site Plan Comments — HN Funkhouser Clearbrook Shell Frederick County, Virginia Dear Mr. Lewis: Upon review of the revised site plan dated November 28, 2018, we recommend approval of the subject plan. t Z f Joseph W. Johnson, P.E. Civil Engineer JCW/kco cc: Planning and Development file Sincerely, 1.! Joe C. Wilder Director of Public Works 107 North ,Rent Street, Second Moor, Suite 200 *"Winchester, Virginia 22601-5000 FREDERICK WATER FREDER.JCK �a .SW I ER.:.Fti SITE PLAN REVIEW COMMENTS PO Box 1877, Winchester, VA 22604-8377 540.868.1061 voice 315 Tasker Road, Stephens City, VjA� 226555 D d4t- Applicant 540.868.1429 fax Project fla w ti �h "1—� I� d VW��, Li' 6, — je � ae- _rftr REVIEW STATUS L Kiva; ti Lrrwt-'�� review numbery correct & resubmit approved as noted number of items to be corrected approved l ou may submit just cover sheet and the revised sheets. DRAWINGS send me by 1. print of sheets PAZ 2. two CDs: each disc shall c ntain the following plan sheets v �� a) One CD (containing all of the above noted sheets) shall be in PDF format. Each sheet shall be in its own file and be in landscape orientation. Each file shall be titled with the project name and appropriate sheet number. b) One CD shall be in DWG format; (1) in Model Space, (2) in state plane coordinate system NAD 83, (3) compatible with AutoCAD 2006. c) Each of the two CDs shall be labeled with its format and project name, and placed in its own paper CD envelope. EASEMENTS / N A copy of the recorded onsite FW easement(s) is/are required. Y /9? A copy of the recorded offsite FW easement(s) is/are required. o The easement document shall contain a plat and both shall be signed by the Frederick Water. o The Frederick Water requires specific language in its deed of easement. o Visit our website www.frederickwater.com to obtain a copy of the form. o A copy of the recorded deed(s) of easement shall be received before service will be authorized. OTHER Y This project also requires DEQ - Valley Region Office approval. Y This project also requires VDH — Lexington Field Office approval. <9 This project also requires VDH — Lexington Field Office — Project Summary Report. BY DATE FOR DRAWINGS ABOVE, see VDH website for form Y This project has a sewer pump station that FW will own. Title to the pump station site shall be granted to the Frederick Water in fee simple absolute. Also, (1) a copy of DEQ's Certificate to Construct, (2) a copy of DEQ's Certificate to Operate, and (3) two copies of the FW approved O & M manual are required. These documents must be received before service will be authorized. (4) Work cannot commence that would connect to FW facilities or require FW inspections until the contract is returned to is office. Date: �% + t/� r ��j Earl W. Wiley — Engineering ssistant JAN 18 john Lewis From: Timothy Rhodes <timothy.rhodes@vdot.virginia.gov> Sent: Friday, January 25, 2019 2:39 PM To: John Lewis Cc: Matthew Smith; Rhonda Funkhouser; Tyler Klein; Edwin Carter; Gregory.Hoffman@vdot.virginia.gov; John Bishop Subject: Clearbrook Shell Site Plan Approval r'r� "': ? 'i< _ �: ' 1 ' A� � �" i c; f y' 1.fit C R N' � � DEPARTMENT OF TRANSPORTATION Staunton/Edinburg Land Development 14031 Old Valley Pike Edinburg, VA 22824 John, A VDOT review has been conducted for the Clearbrook Shell Site Plan signature dated January 10, 2019. Based off of the review of the Drawings, all of the previous VDOT comments have been addressed and the Site Plan is approved by our office. Please ensure that all applicable agencies have the most recent set of approved Drawings. We offer the following general comments: Our review and comments are general in nature. Should details be overlooked during plan review or conditions in the field exist such that additional measures are warranted, such measures shall be completed to the satisfaction of the department. Materials used and methods of construction shall adhere to the current observed VDOT Road and Bridge Specifications, Road and Bridge Standards, Manual on Uniform Traffic Control Devices, and Land Use Permit Special Provisions. A preconstruction conference shall be held by the engineer and/or the developer with the attendance of the contractor, various County agencies, utility companies, and VDOT prior to initiation of work. All drainage is to be carried within the right-of-way in ditch lines or gutters along the street to a pipe or drainage easement. Any construction related changes to the approved plan must come through the design engineer to VUOT for approval. Please allow a minimum of 5 business days for VDOT review. A Land Use Permit shall be obtained before any work is performed on the State's right-of- way. The permit is issued by this office and may require application fees the salary R expenses of a State assigned inspector, and surety bond coverage. Please submit one electronic copy of the plans to this office for file and permitting. If you have any questions or need further information, please do not hesitate to contact me. Sincerely, Timothy Rhodes `� f) C►'r —Land Development Engineer Clarke, Frederick, Shenandoah & Warren Counties 14031 Old Valley Pike Edinburg, VA. 22824 (540)-984-5630