Name of development and description of the request:
Navy Federal Credit Union Building #3
Location of Property:
190 Security Drive
Winchester, VA 22602
Telephone: 540-662-4185
Inspections Department Commen`tcs_
-FREDERICK COUNTY INSPECTIONS DEPARTMENT USE ONLY -
Date Received g� t S i l Review Numb r l 3 4 5 (circle one)
Date Reviewed -7117-/
Revision Required nl c3 , Date Approved 911zl
Signature & Date:'
18 SEP 12 2016
GREENAY
ENG INEER1NC
Building shall comply with The Virginia Uniform Statewide Building Code and Section 304, Business
Use Group, of the International Building Code/2012. Other codes that apply are The Virginia Fire Code
2012, ICC/ ANSI A 117.1-2009 Accessible and Usable Buildings and Facilities and International Energy
Code.
Building shall maintain height and area as required under T503. Building has full NFPA 13 system and
Fire Depart Connection located.
Four story building shall meet Virginia Building Code, Chap 10, for exiting requirements. Exits shall be
continuous from point of entry into the exit to exit discharge. Question on exterior door location at
interior rated stairway. All required egress shall be accessible. Landings shall maintain a maximum 2%
slope and walkways shall be a maximum 5% slope
Question on above grade Walkway if open or enclosed. Question of building required wall and
opening protections as required in IBC Section 705.3 & Section 506 for walkway and generators.
Fire pump room shall be accessible from exterior or be provided with a rated enclosure as required
per NFPA 20; 4.13.2
60% of all entrances shall be accessible
Building overhangs roadway on first floor. The horizontal rating shall be address as required in IBC
Section 506.5, 510.7, and T503.
Handicap Van Parking is required. Minimum width for parking and unloading is 8' w/8' unloading or 11'
w/5' unloading. Accessible parking signage for van shall include $500 fine. See USBC Section 1106.8
for Van accessible signage.
Max slope for walkways is 5%. Maximum slope for landings at door and top/bottom of ramps is 2%.
All required egress/exits shall be Accessible per ANSI Al 17.1-09. Walking surface shall meet ANSI
A 117.1-09 for surface.
Retaining walls shown require building permits and, due to height of unbalanced fill, will require a design
by a Virginia Registered Design Professional.
Please note the requirements in Chapter 17 of BOCA for special inspection requirements on the type of
structure (Soils, concrete etc.) Compaction/soil bearing/soil testing shall be required for placement of
new store.
9/6/17
Walkway shall be separated from new structure as required by the Virginia Building Code. Generators
shall comply with T602/Chap 7 as required. Rated stair enclosure and exits shall meet Chap 10 Virginia
Building Code
2/13/18 Fire Marshal approval required for FDC changes. Changes to water line and conduits shall
comply with the 2012 Virginia Plumbing Code and 2011 National Electrical code
8/10/18 Adding ANSI Accessible Ramp and Retaining walls. Ramp and retaining walls require permits.
Maximum ramp slope 1:12. Maximum length of ramp run 30' (30" rise) before landing is required.
Handrails are required on both sides of ramp. Plans for retaining walls shall be sealed by a Virginia
Registered Design Professional.
S:1Site Plan comments\2012\Business Navy Bld 3.doc
September 17, 2018
Mr. Kevin Seward
Greenway Engineering
151 Windy Hill Lane
Winchester, Virginia 22601
C-70UNT Y of FPEDE1 ICK
Department of Public Works
540/665-5643
FAX: 540/678-0682
RE: Navy Federal Credit Union Building 3 – Revised Drive Aisle between Buildings 2 and 3
Revision #4
Dear Mr. Seward:
Upon review of the updated plan dated August 9, 2018, we recommend approval of the
subject plan.
Joseph W. Johnson, P.E.
Civil Engineer
JCW/kco
cc: Planning and Development
file
Sincerely,
Joe C. Wilder
Director of Public Works
107 North tient Street, Seconal Floor, Suite 200 a Winchester, Virginia 22601-5000
IL
"W 1971
R E E NIWAY
ENGINEERING 11
151 Windy H-111 Lane
Winchester, Virginia X2602
-&mtviovM.Ftrip iAL
Project Name: Navy Federal Credit Union - I
File No: 3015L
Date: Mon, Aug 27, 2018
To: Frederick Water
Attn:
Copied
Earl Wiley
Delivery: Q Fed Ex
Q Other
[] U.S. Mail
#3 Pf[P=OVIC=
AUG 2 8 201
From: Kevin Seward/rf
GREENWAY ENGINEERING
Phone: 540-662-4185
Fax: 540-722-9528
Courier 0 Pick Up
0 Urgent ;/ For Your Review 0 As You Requested ;j Please Comment
Mr. Wiley,
Attached please find the following:
- Two (2) sets of plans
- Revision #4 MEMO
- Review Checklist
- Comment Sheet
- Plan Review Fee Sheet
Message
p LBwyrvRwRw'(
Please feel free to contact us at 540-662-4185 if you have questions or need information.
Thank you I I
I Hand Delivery and Pick Ups Only:
Received by: Date:
Please Print Name:
REQlilFST >` OR SITE PLAN COMMENTS
Frederick C ount!i Fire '1lrtrshal Comment
_Mall to.
l'fcdctick C.'ounty.ire Marshal
Amit): Fir IM—m-skal
1080 C ovLrstono Drive
Wincheslor, Virginia 22602
Hand deliver to:
1'ttkllic Safety Bttildirt,
1090 COVerstone live
W nchester-, Virginia 22602
Phone: (540) 665-6354
Apnticard. It iS y+.nrr rctil?nnsiih ltfy 113 cctitnrleto This Cisme .r, wi:.malcly dti ptrwslbio it) order to assist the lYfiftCy Wilk their 11
rc� is ��. I'lt r :ali;ec_lti twit (L) copics ortho Site Platt tWtth chip :ttii t,
Applleaw'4 Name: GreenwayEngineerrg, Inc. [l ;fplIGne: 540-662-4185
E-maii .Xd l:,:ss. -keWerggroenwayengccmi
'tii:iiliti ldclro; 151 % rmdy 'i Lane
Nam of devc1eiament and descriphOn Of the re(jUe-,t:
?davy Feoc-r.'r! CFr^rliS Urrion Buoding 43
Locfttlon, of f)i"Qq' aty:
190 So(Awly DrIvo
Win .he::€r, VA '2tpP
.1. Zulu
f iEe Ittrsl�,lf Comments:
ffJ jj
-FREDERICK �.Ut✓N1VIR 1•;,i+,RS11AL LISL t7N Y- i
Unto Iti i.wivcrt Review N'LlIllbed 1 2 3 4 5 (cirde cine)
Oulu lZ v is k o d''"
�ct�itii n I�.��I�iic��:l�,t'�c+__- 1�n� ll,,iit•�?Vccl, - t �'�--�t,�`
Pun t ft;toni Fortil tq Applicant
Date Received
811512018
Frederick Bounty
Department OfFir-e and Rescue
Office of the Fire Marshal
108V Comrstone Drive if i�rrliCsrrr, AFA 22602
(546)665-6350 Fax (540)678-4739 Eu1arl: f1z1Opfcya.1,,
Plan I evict r & Comments
PlanrPerrn t Type Site Plan Rev. #4 08-15-18
Name Navy Federal Credit Union
Address 190 Security DR Winchester
Project Name
Applicant Name # Number
RE#
Permit Number
Emergency Vehicle Access:
Hydrant Location:
Siamese Location:
Fire Lanes Required:
Plan Approval Status
NFGU Building 3 0(101760
Greenway Engineering 540-662-4185
Permit #1760-2017
Auate
Inadequate
NIA
Aute
Inadequate
NLA
Adequate
Inadequate
NLA
J
S
No
NLA
Approve
Comments
Areas hl-llghted In orange shall have No Parking Fine Lane signs Installed
Areas hi -lighted In ,yellow shall be striped in yellow
y -
Signature; --
Reviewed By. Kenneth Scott, Jr.
r r
Title-.
Date Reviewed
812212018