HomeMy WebLinkAbout19-18 CommentsLori Fairfax Health District - L (>D n Frederick / Winchester Environmental Health OI 107 North Kent Street - Suite # 2001 .«moi VAIRWAIX Winchester, Virginia 22601 HEALTH DISTRICT Tel. (540) 722-3480 - Fax (540) 722-3479 www vdh.vir i,� nia.gov May 24, 2018 Agency Comments: // VIRGINIA DEPARTMENT DHOF HEALTH Protecting You and Your Environment This Health Department has reviewed the request for comments for a Site Plan fora proposed Special Event Center, to be located at 283 Barracks Lane Winchester VA 22602; Tax Mqp #: 52-A-261 Based upon information provided by the applicant, the proposed usage meets the design criteria of the approved sewage disposal system: 1) The duration of the event will not begin before 10:00 AM and will end at midnight (12:00 PM); 2) The proposed event will accommodate but not exceed 280 persons; 3) The proposed days of operation are to be Friday Saturday, & Sunday. The water supply for the proposed event center will consist of drilled wells permitted by the Office of Drinking Water. There will be no food service in the event center, as the sewage disposal system can only accommodate restroom usage. This Health Department therefore has no objections to construction of the Special Event Center. Applicant is welcome to contact this Health Department at (540) 771-3020, or (540) 722-3480 concerning questions about any part of this correspondence. Page l Page 2 Agency Sin,iature• r :i�.,� �- � �1a.}.G� .Date: Title: E \,A NOTICE TO AGENCY PLEASE RETURN THIS FORM TO THE APPLICANT) REQUEST FOR SITE PLAN COMMENTS Frederick County Inspections Department Comment Mail to: Frederick County Inspections Department Attn: Building Official 107 North Kent Street, Winchester, Virginia 22601 Hand deliver to: Frederick County Inspections Dept. 107 North Kent Street, 2" d Floor Winchester, Virginia 22601 Phone: (540) 665-5650 Applicant: it is your responsibility to complete this form as accurately as possible in order to assist the agency with their review. Please attach two. (2) copies of the Site Plan with this sheet. Applicant's Name: GreyWolfe, Inc. - Gary R. Oates, LS -B, PE Telephone: 540-667-2001 Mailing Address: 1073 Redbud Road Winchester, Virginia, 22603 Name of development and/or description of the request: Dixie Scheulen Special Event Center - CUP 07-17 Location of Property: 283 Barracks Lane, Winchester, Virginia, 22602 Inspections Department Comments: ** Please: Return Form to App icattt** 19 Buildings shall comply with The Virginia Uniform Statewide Building Code, and Section 303 - A,Assembly Use Group of the Virginia Building Code/2012. Other Code that applies are the International Energy Code, ICC/ANSI Al 17.1-09 Accessible and Usable Buildings and Facilities. Design plans submitted for permit application shall be sealed by a Virginia Licensed Design Professional. Occupant load and fire egress plans shall be indicated on sealed plans at time of submittal. New assembly building shall meet height and area for the type of construction as allowed in T503 with applicable increases. Buildings on the same lot shall comply with T602 for fire separation distances. All required egress shall meet ANSI Al 17.1-09 for slopes. 60% of all public entrances shall be accessible. Vestibule or air lock provided as required for entrances opening into a space exceeding 3000 sq ft. Parking is provided in accordance with T1106.1(1) of the IBC. Vehicle unloading areas shall be striped in accordance with ANSI A117.1-09. A minimum of one van accessible parking and unloading is required. Max slope of accessible parking and unloading areas shall not exceed 2%. Signage for parking shall be provided as required per USBC 1106.8. Sidewalks that exceed a 1:20 slope shall be designed as a ramp. Curb ramps shall maintain a 1:12 maximum slope. Maximum 1/2" door threshold is allowed per ANSI Al 17.1-09 Demolition of any structure requires a building permit and an asbestos inspection. Restroom quantities shall be determined by Assembly Use Group Use based on the occupant load in T2901. Health Department approval for the sanitation system is required with occupant load. Gutters shall not drain over walking surfaces. Drains beneath patio and walkways are detailed on plans. Calculations on storm drain (roof drains) shall be per The Virginia Plumbing Code 2012 and be provided with the plumbing permit application Please note the requirements in Chapter 17 of IBC for special inspection requirements on the type of structure.( Soils, concrete etc..). S:\Site Plan comments\2012\Assem Event Center.doc 14FOITST FOR Sl I'l PLAN COMMUNTS Fredi-rick Count) Public %Vorkc Comment Mad to. lUmd dcliver to: TI—jc, r'jd, Counix i"'iddic WilrkS Dcparv,)icrt hillic Works 1.1cparlincm "7 N-rh Kent Sirccl- !7 virginimk I`fs�jl Applicant., t9L 1� I hik L Ok- V Ap;lli,am',cr Name- ontes 1 MAY 2 1 2018 f. Noow oI doviopment aridor dc,;ctspion o! the requo-C F*,!�r! f7fanter-CUP U -17 I , ii;.Itloll of Prorcm - 2H3 kir-wcb�5 Lare, WoCh�orlp.r Virg 4-4� pirija i Rl fa F: 4 OUN I N PUBLIC N%"oRk% DEPART ATF 7 USF ONXI. A D'wt. . . ........ z Subject: Dixie Scheulen Special Event Center Date: 6/28/2018 1:23:30 PM Eastern Standard Time From: timothy.rhodes@vdot.virginia.gov To: greywolfeinc@aol.com Cc: matthew.smith@vdot.virginia.gov, rhonda.funkhouser@vdot.virginia.gov, edwin.carter@vdot.virginia.gov, tklein@fcva.us Gary, A VDOT review has been conducted on the Dixie Scheulen Special Event Center Site Plan dated May 14, 2018. The existing access on Rte. 803 serving the property will be sufficient for the proposed use. This office has no objection to the proposed Site Plan. Should you have any questions, please feel free to contact me. Thanks You, Timothy Rhodes VDti3 —Land Development Engineer Clarke, Frederick, Shenandoah & Warren Counties 14031 Old Valley Pike Edinburg, VA. 22824 (540)-984-5630 Fredefick Cauj7tj, Departm,pnt of Fire and Resci -fe Office of the Fire Marsiral 108'y COW'T'rol" Drfv 114,0CIII-Ifff, V4 226172 �-'40""'5 63-5t' Ta (54-0) G-8 4,739 _FmaLl: Plan Revie-%&, & Comments Diate Recefved -512112018 PlanlPerraft Type Site Plan 05-21-18 Name Caroline "Dixie- Boyd Scheulen Address 283 Barracks LK Winchester PrOleGt Narne Event Venue APPlicant Name & Number C1reYW01fe, fnc. 540-667-2001 RE# Permit Number Emergency Vehicle Access.- A�qUate Inadequate NIA Hydrant Location, Adeouate Inadequate JA Siamese Location- Adequate Ykadequiate N W Fire Lanes Required- No N/A Plan Approval Swus APProve Comments AMRS 111 -lighted in orange shaft have NO Parking Fire Lana sign installed Signature: Reviewed By, Kenbeth Sco"tt,Jr. Title: tz— - Lti AA $' Date Reviewed 5/2'512018 VA 22602