Loading...
HomeMy WebLinkAbout11-18 Site PlanPARKING SPACE CALCULATIONS REQUIRED PARKING 1 SPACE PER STAFF, PLUS 4 VISITORS 75 STAFF = 79 SPACES REQUIRED (4 HANDICAP) EXISTING PARKING 159 AUTOMOBILE SPACES (6 HC) 23 BUS SPACES 4 ..TERSTATE 81-S PROPOSED PARKING y ••R%W VARIES} NO ADDITIONAL PARKING PROPOSED 'INTERSTATE 81.-N (R/W VARIES) 60' FRONT .AYLOR RD - SETBACK - - e s 16 PIN 75-A-54 SETS�..? ° FREDERICK COUNTY ,pm A, "SCHOOL BOARD0' �et - DB N/A PO N/A AR ZONING: RP I I s ,. USE: EDUCATIONAL SCH' `:, 20 �x¢ -�21 22 ..PROPOSED TEMPORARYr' 231 CLASSROOMS UNIT 24J I APPROVED BY FREDERICK COUNTY ZONING ADMINISTRATOR k THIS SITE PLAN SHALL BE VALID FOR A PERIOD OF FIVE (5) YEARS FROM DATE OF APPROVAL. SITE PLAN APPROVAL DATE I b s.a I I - Ib TABLE OF CONTENTS C101 OVERALL SITE PLAN C102 SITE PLAN AND DETAILS C103 MODULAR UNIT ELECTRICAL PLAN C104 EXISTING BUILDING WIRING PLAN OVERALL SITE PLAN 100' 50' 0 100' 200' 1" = 100'-0" _ 26 l I LEGEND EXISTING DEMO NEW DESCRIPTION -205�J - - --- 050 - CONTOURS CONCRETE CURB CONCRETE CURB & GUTTER CONCRETE PAD/WALK PAVEMENT GRAVEL BUILDING SITE FEATURES x x x x X X FENCING - - - - - - PROPERTY UNE CENTERLINE OR BASELINE -- - OHE--- OHE- OHE ELECTRIC - OVERHEAD --- UGE--- -UGE- -UGE ELECTRIC - UNDERGROUND - - - UGT - - - - UGT- UGT- TELEPHONE - UNDERGROUND --- FO --- - FO - FO FIBER OPTIC - UNDERGROUND G G - G GAS LINE SS -SS -SS- SANITARY SEWER W W - W - WATER LINE FIRE HYDRANT ( (� HANDICAP PARKING TREE LINE -r T SIGNS UTILITY CONTACTS COMCAST COMMUNICATIONS 195 RAINVILLE ROAD WINCHESTER, VA.22602 WASHINGTON GAS P.O. BOX 2400 WINCHESTER VIRGINIA 22604 VERIZON 404 HILLANDALE LANE WINCHESTER, VIRGINIA 22602 SHENANDOAH VALLEY ELECTRIC COOPERATIVE 3463 VALLEY PIKE WINCHESTER, VIRGINIA 22602 RAPPAHANNOCK ELECTRIC COOPERATIVE 137 KELLEY COURT FRONT ROYAL, VIRGINIA 22630 FREDERICK WATER P.O. BOX 1877 WINCHESTER VIRGINIA 22604 ZONING INFORMATION ZONING: RESIDENTIAL PERFORMANCE REQUIRED MINIMUM SETBACKS: FRONT 35' SIDE 15' REAR 50' PROVIDED SETBACKS: FRONT 283.13' SIDE 251.53' REAR 167.27' TEMPORARY CLASSROOMS ARE ACCESSORY TO THE EXISTING SCHOOL AND ARE ALLOWED IN THE OVERALL SETBACK AREA. BUILDING HEIGHT: MAXIMUM HEIGHT 45' PROPOSED HEIGHT 16'-8" ADJACENT PROPERTY INFORMATION 1. FOX, GROVER T; PIN 74B-5 1-2; ZONING: RP; USE: RESIDENTIAL 2. KULP, JOAN C; PIN 748-5 1-3; ZONING: RP; USE: RESIDENTIAL 3. BENNETT, KAREN; PIN 74B-5 1-4; ZONING: RP; USE: RESIDENTIAL 4. HINES, RALPH W & LYNDA K; PIN 74B-5 1-5; ZONING: RP; USE: RESIDENTIAL 5. KEPLINGER, HARLAN C; PIN 74B-5 1-6; ZONING: RP; USE: RESIDENTIAL 6. KEPLINGER, HARLAN C; PIN 74B-5 1-7; ZONING: RP; USE: RESIDENTIAL 7. EMORY, CHARLES E JR & CHRISTINE; PIN 74B-5 1-8; ZONING: RP; USE: RESIDENTIAL 8. MENDOZA, LARRY D & BEVERLY J; PIN 7413-5 1-9; ZONING: RP; USE: RESIDENTIAL 9. MCMANIGLE, SETH D & JAIME L SOLENBERGER; PIN 748-5 1-10; ZONING: RP; USE: RESIDENTIAL 10. STEPHENSON, MICHAEL R & CHERYL A; PIN 74B-5 1-11; ZONING: RP; USE: RESIDENTIAL 11. EARNSHAW, HERBERT I & RUTH M; PIN 74B-5 1-12; ZONING: RP; USE: RESIDENTIAL 12. RYDER, KENNETH D & STEPHANIE B; PIN 74B-5 1-13; ZONING: RP; USE: RESIDENTIAL 13. DRIVER, ERIN B & SLOANE, BRYAN E; PIN 74B-5 1-14; ZONING: RP; USE: RESIDENTIAL 14. ASJODI, MIKE MEHDI & ASJODI, CAROLYN SUE; PIN 86 -A -5A; ZONING: RP; USE: RESIDENTIAL 15. SHIFFLETT, RAY MARVIN; PIN 75-A-52; ZONING: RP; USE: RESIDENTIAL 16. SHIFFLETT, RAY MARVIN; PIN 75-A-53; ZONING: RP; USE: RESIDENTIAL 17. SALE, GARRY D TRUSTEE & ZEBULON B; PIN 74B-11 1-1; ZONING: RP: USE: RESIDENTIAL 18. TALLEY, JANET DIANE; PIN 74B-11 1-2; ZONING: RP; USE RESIDENTIAL 19. PEREIRA, JOSHUA LOUIS & ADELE MARIE; PIN 74B 11 1-3; ZONING: RP; USE: RESIDENTIAL 20. KEVIN PATTON LLC; PIN 74B-11 1-4; ZONING: RP; USE: RESIDENTIAL 21. LAYMAN, CYNTHIA J; PIN 748-11 1-5; ZONING: RP; USE: RESIDENTIAL 22. MIDKIFF, EDWARD W & JASMINE R; PIN 74B-11 1-6; ZONING: RP; USE: RESIDENTIAL 23. WYMER, CHRISTOPHER S; PIN 74B-11 1-7; ZONING: RP; USE: RESIDENTIAL 24. SHERMAN, FORREST A & LINDA W; PIN 74B-11 1-8; ZONING: RP; USE: RESIDENTIAL 25. BS RENTALS LLC; PIN 74B-11 1-9; ZONING: RP; USE: RESIDENTIAL 26. COLE, ORAL JEREMIAH; PIN 7413-11 1-10; ZONING: RP; USE: RESIDENTIAL GENERAL NOTES 1. OWNER: FREDERICK COUNTY SCHOOL BOARD SUPERINTENDENT OF SCHOOLS 1415 AMHERST STREET WINCHESTER, VA 22601 (540) 622-3888 2. ARCHITECT/ENGINEER: OWPR, INC. 200 COUNTRY CLUB DRIVE PLAZA ONE, BUILDING -E- BLACKSBURG, VA 24060 (540) 552-2151 FAX (540) 951-0219 3. SITE AREAS: TOTAL SITE AREA 23.90 ACRES TOTAL DISTURBED SITE AREA 0.03 ACRES 4. ZONING: RESIDENTIAL PERFORMANCE (RP) 5. MAGISTERIAL DISTRICT: OPEQUON 6. BUILDING INFORMATION: MOBILE UNITS HEIGHT: 1 STORY - 16'-8' BUILDING USE: EDUCATIONAL BUILDING AREA: 111,602 S.F. (EXISTING) 7,106 S.F. (TEMPORARY) 118,708 S.F. (TOTAL) 7. PROPERTY INFORMATION: TAX PARCEL:- 75-A-54 CURRENT USE: ELEMENTARY SCHOOL PHYSICAL ADDRESS: 901 AYLOR RD STEPHENS CITY, VA 22655 8. CONTRACTOR SHALL HAVE A LICENSED LAND SURVEYOR RESET ANY BENCHMARKS DISTURBED DURING CONSTRUCTION AND SHALL NOTE THE NEW LOCATION AND ELEVATION ON THE AS -BUILT DRAWINGS. 9. ALL EXISTING SITE FEATURES DAMAGED AS A RESULT OF THE CONTRACTOR'S ACTIONS SHALL BE REPLACED OR REPAIRED AS DIRECTED BY THE ARCHITECT/ENGINEER AT NO ADDITIONAL COST TO THE OWNER. 10. A PRE CONSTRUCTION MEETING WILL BE HELD PRIOR TO BEGINNING CONSTRUCTION. 11. IT IS THE CONTRACTOR'S RESPONSIBLILTY TO MEET COMPLIANCE REQUIREMENTS WITH SECTION 59.1-406.ET.SEQ., OF THE CODE OF VIRGINIA (OVERHEAD HIGH VOLTAGE LINES SAFETY ACT). 12. FREDERICK WATER PROJECT INFORMATION - NO CHANGE IN WATER AND SANITARY SEWER DEMAND OR USAGE. 13. PREVIOUS APPROVED SITE PLANS INCLUDE: - SITE PLAN (SP) #01-91. 14. NO PROPOSED CHANGES TO SITE SIGNAGE OR LANDSCAPING INCLUDED IN THIS PROJECT. 15. NO PROPOSED BUILDING -MOUNTED OR POLE -MOUNTED SITE LIGHTING INCLUDED IN THIS PROJECT. SURVEY NOTES 1. TOPOGRAPHIC INFORMATION SHOWN HEREON IS BASED ON FREDERICK COUNTY GIS DATA AND AERIAL PHOTOGRAPHY. 2. THE BOUNDARY INFORMATION WAS PREPARED WITHOUT THE BENEFIT OF A TITLE REPORT. 3. ANY UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. THE SURVEYOR MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM INFORMATION AVAILABLE. 4. BOUNDARY DISTANCES AND BEARINGS PROVIDED WERE TAKEN FROM EXISTING RECORD DRAWINGS AND HAVE NOT BEEN VERIFIED. THIS PLAT DOES NOT CONSTITUTE A BOUNDARY SURVEY. 6 aCT Hama,i �OmEd c N w Z w 0 z / a V u, O � x V J 0 fn N ro m O o U z Z o J O 0 O Q � I C (n a � Q d OJ U N a Q 0 U O Q N J U I m 0- :2 U Li 0 0 No. Description Date Revisions 0 fn N ro m m o Z o � a � E C 3 L)p N r CL a 0 U O N N U 0 0 No. Description Date Revisions z Q J 0- LLJ J J Q LLJ O fn N m m a C 3 L)p N r CL a 0 U Q z Q J 0- LLJ J J Q LLJ O p P U. 4 :, L 1` SITE PLAN NOTES q�PVTH nF v l [ ' 'fix • : I '1)� ; c.' " e t 1. ALL DIMENSIONS SHOWN ARE TO FACE OF BUILDING, FACE OF CURB, EDGE OF AND PERPENDICULAR WILLIAM A.SHELTON Iµ PAVEMENT, TO PROPERTY LINES. Lia. No. 031657 - f 4 (:_� 7 C'^1 ! r.I i; 2. CONTRACTOR SHALL CONTACT "MISS UTILITY (800-552-7001 FOR MARKING OF II V i {.i , UTILITIES 72 HOURS PRIOR TO ANY EXCAVATION OR CONSTRUCTION. I'_t IMAN _t' 3. UTILITIES SHOWN ON THESE PLANS REPRESENT UTILITY LOCATIONS AS DETERMINED orG CONAL I-I (�' r4rj j'1. ..-_. FROM AERIAL PHOTOGRAPHY. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION Y I (r'+•I rry I'`—.._> BK' 1F- •� I ••',=s•-,.,,;, • '" OF ALL UTILITY LOCATIONS, DEPTHS AND SIZES PRIOR TO CONSTRUCTION. IF EXISTING Rob�., ilt <� A��K ...:, _ e -.. �_� _ 4 "I _ _ ::�_ _:,fir - ;;,. LL , ,, .... -• CONDn10NS ARE DIFFERENT THAN THAT WHICH IS SHOWN ON THE DRAWINGS, NOTIFY ,3„w ..V_• II I b. E� ,=, THE ARCHITECT/ENGINEER IMMEDIATELY. II - F I '._n, 4. THERE MAY EXIST UTILITIES WHICH HAVE NOT BEEN SHOWN ON THE PLANS AND OF 8 'I 4` ��'�--1'_ -. - -- I t I.E1 ;..- 'ceyc` '- - — _ _ e'- ,;y r, a, ('I ''' I .I -� WHICH THERE IS NO RECORD. IF ACTIVE UTILITIES ARE ENCOUNTERED WHICH WERE =m�' � e `-` '-' h. -`•.... j 7 ! s »+r,r t'I NOT INDICATED ON THE DRAWINGS, CONTRACTOR SHALL CONTACT THE APPROPRIATE UTILITY COMPANY AND THE ARCHITECT/ENGINEER IMMEDIATELY. CONTRACTOR SHALL a m a LL 33 �, a ,I I („E=+z aft 1 IRit. ta';, ! . _.. ,r / �5. _' if"di - - _ -, - -� As�lcul.,=„ f.� I `" , .. TAKE NECESSARY STEPS TO RESTORE UTILITY SERVICE TO ANY DAMAGED UTILITIES AS �+ r i ,. � "—t I ,t ,I r I. ` �� ;. � ii' i•- - �,; Irl ru«,ral �': Arlo- III ,. : _.'. v SOON AS POSSIBLE. ` �i �� ac+a w cc Irmo 9 _ :.._li , t -=1 1;106 M + u,-,AoE O � '-' U� t ,� IS:CH^ larJFh�P- '-!1,t :. lI L - {' .- 5. CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL UNDERGROUND UTILITIES BEFORE COMMENCING WITH CONSTRUCTION. z k - - r, Lri i! a PCU'TUcL - 11 z CLA§tiR'TOM � (I II ( w i r+.'+�,`—"`"' I�. o n^r Is on,cs,L.. __ *.,' ,+ ---- - �-----"- -- .. " FH - 6. THERE SHALL BEARE CONSTRUCTION MEETING WITH THE CONTRACTOR,FklST ARCHITECT/ENGINEER, THE OWNER PRIOR TO BEGINNING CONSTRUCTION. p EXIST BUS 7. MODULAR TRAILER UNIT LENGTHS MAY INCREASE ONCE MATED TOGETHER. CONTRACTOR SHALL ENSURE CANOPY AND RAMP SYSTEM UNE UP WITH DOUBLE DOOR PROVIDE 1.'C. W/ PULLSTRNG "�,-_PROPOSED CANOPY, (2) BOLLARDS = LOOP AS SHOWN ON THE SITE PLAN. ELEC NOTE 6ROM (3' F FH) COORD. Wf OWNER LL, 30' MIN c� o COORDINATE EXACT LOCATION • ' 8. CONTRACTOR SHALL DISPOSE OF ALL SPOILS AND EXCESS MATERIAL OFFSITE, TO AN O (FIRE TRUCK PROVIDE 1"C FOR = = w T OF PENETRATION WITH OWNER 4'-- MATCH FLUSH APPROVED DUMP SITE. a ACCESS) SAS/FIRE ALARM, PROVIDE 2"C FOR DATA MATCH FLUSH o z W/ EXIST - Z ASPH PVMT ELEC NOTE 3— I FROM NEAREST CLASSROOM, W/ EXIST --- --------57.50'--- -- _--E -... -.-.._109.33' ELEC NOTE 4, 5 ASPH PVMT------t50'----{-- (TYP) `,...: 7' (TYP) ELECTRICAL NOTES J I_.--1'0. 3' DEEP 0 i� z RAMP SHALL BE PROVIDED BY CONCRETE FOOTING ( PROVIDE PAVED FIRE _ LANE ACCESS TO �` 1. PROVIDE A ELECTRICAL SERVICE, PROVIDE A NEW SERVICE ENTRANCE RATED PANEL MDP: 0 F MOBILE UNIT MANUFACTURER l EXIST ASPH PVMT 1200 AMP, SINGLE PHASE, 240/120 VOLT PANEL WITH A 1200 AMP MCB. PROVIDE 8, 2 POLE, = Z S AND SHALL BE ADA ACCESSIBLE RAMP SHALL BE PROVIDED BY 150 AMP BREAKERS TO FEED MODULARS. PROVIDE 3-1/0 CONDUCTORS AND 1—#6 GROUND IN U MOBILE UNIT MANUFACTURER 2131a CONDUIT FROM NEW PANEL MDP. N :D AND SHALL BE ADA ACCESSIBLE .t EXIST TEMPORARY CLASSROOMS UNIT 2. PROVIDE 1-20 AMP SINGLE POLE BREAKER TO FEED A CONVENIENCE RECEPTACLE LOCATED w ASPH PVMT o .(6,695.11 TOTAL SF} AT MOUNTING RACK. PROVIDE #12 WARE AND /12 GROUND TO CONNECT CIRCUIT. J 0 (728.56 SF PER CLASSROOM) _ _ 3. EXISTING FIRE ALARM SYSTEM IS LOCATED IN THE MAIN ELECTRICAL ROOM. COORDINATE EXACT M O °O ` LOCATION WITH OWNER. PROVIDE A NEW FIRE ALARM CONTROL PANEL IN MODULAR UNITS. 0 I 1' PROVIDE RELAYS TO INTERFACE WITH EXISTING FIRE ALARM PANEL. EXISTING FIRE ALARM N REMOVE ASPH PVMT SYSTEM IS ANALOG SYSTEM. ALL NEW DEVICES ARE TO BE FED FROM NEW FIRE ALARM PANEL NECESSARY FOR CLASS SROOM LOCATED IN MODULAR TEMPORARY CLASSROOMS. ACTIVATION OF A FIRE ALARM DEVICE IN N UNIT INSTALLATION EITHER BUILDING SHALL ACTIVATE NOTIFICATION DEVICES IN BOTH BUILDINGS. or - 4. 4. PROVIDE FIBER FROM NEAREST DATA CLOSET TO NEW DATA SWITCH LOCATED IN TEMPORARY O U CLASSROOMS. COORDINATE WITH OWNER FOR FIBER CONNECTOR AND SIZE REQUIREMENTS. _j rn 750 AMP PANEL EXIST / i�l�, - 5. PROVIDE CONNECTIONS FOR EXISTING PUBLIC ADDRESS SYSTEM. EXISTING PUBLIC ADDRESS Q 120/240 V, SINGLE PHASE ASPH PVMT ,�y .�----X- HEADEND IS LOCATED IN THE MAIN OFFICE AREA. PROVIDE ADDITIONAL CARDS IN EXISTING Q (TYP OF 8) „ {1 ZONEHEADEANDND T� CORRIDOR DOR AS EXPAND INDIVIDUAL TO M�ONE 8 NEW CLASSROOMS EACH AS AN INDIVIDUAL J 6. PROVIDE 7 UTHONIA, OFM LED P1 50K MVOLT DDB HP17 OR EQUAL LIGHTS MOUNTED ON 0 w N UX, BASKETBALL GOALS TO BE REMOVED AS / UNDERSIDE OF CANOPY. EQUALLY SPACE LIGHTS ALONG CANOPY. CONNECT LIGHTS TO SPARE 20 AMP CIRCUIT IN PANEL LOCATED IN TEMPORARY CLASSROOM. PROVIDE A PHOTOCELL MOUNTED ON TEMPORARY CLASSROOMS TO CONTROL FIXTURES. PROVIDE #10 WIRE AND /10 0 U NECESSARY BY FOPS I `" Y GROUND TO COMPLETE CIRCUIT. (TMP) REMOVE AND REPLACE / PVMT ASPH AS NECESSARY FOR ELEC COP7D'UIT EXIST MATCH EXISTING ASPHALT PAVEMENT SECTION "yam 'u •-a w w ��.+,<44 �`" PROVIDE 3 1/0 #6, 2'C ' PVMT INCLUDING ANY INTERMEDIATE OR BASE COURSES. r0 EACH PANEL r'.. STL TROWEL FIN Z o _� - / / III (TYP OF 6} t -.�{r- - SEALED CONIC � 12" PATCH 12" MIN WIDTH MIN E E o RAPPA'iAtT'.vCE.A f!tJTR't TO /J -.. _ --.. �� -�"` PROV01E NEW T,tu1PORAR" POLE /-ELEC NOTE ! 1, 2 ,:.:.-�"-'-""� -� n-. CJ N AND POWER FROM ACROSS ROAD \•, �� 6"0 SCH 40 ,._ --�---' _ -k- "` STL PIPE W/ .: ..:,. CONIC FILL (PAINT) 3 3 PROVIDE MOUNTING RACK r'" r;r r . . SAWCUj _----rE WITH COMPONENTS w AS - a.-- PVMT EDGE ED VDOT SHOWN IN DETAIL , u` 1- ( MIN) 21-A (1 A 18" IN IN) mw � 'o t — N P1 0 r ftD G OHt = PAT PAVEME DETAIL NTNG a RAPP Et.E '`" :.`. ..,>E....I. ;, ......: CONCRETE a p p U Q �-- TkpHE : �"""" x.• - TOP SCALE�N ... t .. "_. • - PANEL MDP PROVIDE RACK " MEMBERS WITH COMPRESSIBLE o o TAPPING HOLES FOR JOINT FILLER PROVIDE RACK POSTS CONSTRUCTED °o o BRACKETS OF 12 GAUGE GALVANIZED STEEL ° ° BEAMS WITH TAPPED HOLES FOR °o ° CT CABINET CII .a. - BRACKETS IN 2 FEET OF CONCRETE ° II II I I I I II II I I o METER MOUNTED J .a. o o TO OPPOSITE SIDE Q Z OF CT CABINET o ALL CONNECTIONS ° LLJ ° 3/4"0 in SHALL BE WIELDED °o Q Y0' WELDED KEY o ° oJCONVENIENC _ PROVIDE HORIZONTAL MEMBERS OF°°7.5'---}�7.5':L12 GAUGE GALVANIZED STEEL WITH ° °NOlEP2ACLE, Z 2" ASPHALT M TAPPED HOLES FOR BRACKETS °o °o Q SURFACE COURSE o °o GRADE VDOT SM -9.5A - ° ° ° ° Z 1/4":1' SLOPE KEYa Q CONCRETE FOOTING .ju, I I". 8" AGGREGATE 1'- " (4,000 PSI) BASE COURSE vDOT 21-B CONCH LLJ -� 24" COMPACTED SUBGRADE BOLLARD DETAIL N FIRE LANE SECTION MOUNTING RACK NO SCALE NO SCALE NO SCALE SITE PLAN D 1" 20' 10' 0 20' 40' = 20'-0" V 1 O2 No. Description Date Revisions 4 � I I I I I I I I I I I II (1I ® y I I I I � I I I I I II II TOTAL MODULAR UNIT - 6,695.11 SF I I I DATA DROP DATA DROP DATA DROP DATA DROP I CLASSROOM CLASSROOM (728.56 SF) (728.56 SF) CLASSROOMIE CLASSROOM (728.56 SF) WIRELESS (728.56 SF) WIRELESS ACCESS ACCESS I I POINT POINT II I DATA DROP DATA DROP DATA DROP DATA DROP CEILING MOUNTED NETWORK CLOSET I CONDUIT FOR NETWORK CABLES IP CAMERA I DATA DROP f DATA DROP DATA DROP DATA DROP CLASSROOM CLASSROOM (728.56 SF) (728.56 SF) WAP (728.56 WAP(728.56CLASSROOM (728.56 SF) PROVIDE CONDUIT WITH PULL WIRELESS WIRELESS CHORDS FROM DATA BOX TO ACCESS ACCESS ABOVE CORRIDOR CEILING, TIP POINT POINT DATA DROP DATA DROP DATA DROP DATA DROP lr= V V V V V V CORNER MOUNTED IP CAMERA CORNER MOUNTED IP CAMERA i MODULAR UNIT ELECTRICAL PLAN 0 - ZL SCALE: 1.5" = 1 FOOT 0 0 No. Description Date Revisions m J 0 N ^o o a E E O U � � 0 N � Z s Cl ) =D d m 0 0 (n s n � (n Q a OJ U N Q < Of Q (� C x U CL N LL - 0 Z 0 N ^o o a E E O U � � 0 N C103 N N m 3 3 d m 0 3 s n aN (� Q C103 m N 1 N