HomeMy WebLinkAbout11-18 Site PlanPARKING SPACE CALCULATIONS
REQUIRED PARKING
1 SPACE PER STAFF, PLUS 4 VISITORS
75 STAFF = 79 SPACES REQUIRED (4 HANDICAP)
EXISTING PARKING
159 AUTOMOBILE SPACES (6 HC)
23 BUS SPACES
4 ..TERSTATE 81-S PROPOSED PARKING
y ••R%W VARIES} NO ADDITIONAL PARKING PROPOSED
'INTERSTATE 81.-N
(R/W VARIES)
60' FRONT
.AYLOR RD - SETBACK
- - e
s
16
PIN 75-A-54 SETS�..? °
FREDERICK COUNTY ,pm
A,
"SCHOOL BOARD0' �et -
DB N/A PO N/A AR
ZONING: RP I I s
,. USE: EDUCATIONAL SCH' `:, 20
�x¢ -�21
22
..PROPOSED TEMPORARYr' 231
CLASSROOMS UNIT 24J
I
APPROVED BY FREDERICK COUNTY
ZONING ADMINISTRATOR
k THIS SITE PLAN SHALL BE VALID FOR A PERIOD
OF FIVE (5) YEARS FROM DATE OF APPROVAL.
SITE PLAN APPROVAL
DATE I b
s.a I I - Ib
TABLE OF CONTENTS
C101 OVERALL SITE PLAN
C102 SITE PLAN AND DETAILS
C103 MODULAR UNIT ELECTRICAL PLAN
C104 EXISTING BUILDING WIRING PLAN
OVERALL SITE PLAN
100' 50' 0 100' 200'
1" = 100'-0"
_ 26
l I
LEGEND
EXISTING DEMO NEW DESCRIPTION
-205�J - - --- 050 - CONTOURS
CONCRETE CURB
CONCRETE CURB
& GUTTER
CONCRETE PAD/WALK
PAVEMENT
GRAVEL
BUILDING
SITE FEATURES
x x x x X X FENCING
- - - - - - PROPERTY UNE
CENTERLINE OR BASELINE
-- - OHE--- OHE- OHE ELECTRIC - OVERHEAD
--- UGE--- -UGE- -UGE ELECTRIC - UNDERGROUND
- - - UGT - - - - UGT- UGT- TELEPHONE - UNDERGROUND
--- FO --- - FO - FO FIBER OPTIC - UNDERGROUND
G G - G GAS LINE
SS -SS -SS- SANITARY SEWER
W W - W - WATER LINE
FIRE HYDRANT
( (� HANDICAP PARKING
TREE LINE
-r T SIGNS
UTILITY CONTACTS
COMCAST COMMUNICATIONS
195 RAINVILLE ROAD
WINCHESTER, VA.22602
WASHINGTON GAS
P.O. BOX 2400
WINCHESTER VIRGINIA 22604
VERIZON
404 HILLANDALE LANE
WINCHESTER, VIRGINIA 22602
SHENANDOAH VALLEY ELECTRIC COOPERATIVE
3463 VALLEY PIKE
WINCHESTER, VIRGINIA 22602
RAPPAHANNOCK ELECTRIC COOPERATIVE
137 KELLEY COURT
FRONT ROYAL, VIRGINIA 22630
FREDERICK WATER
P.O. BOX 1877
WINCHESTER VIRGINIA 22604
ZONING INFORMATION
ZONING: RESIDENTIAL PERFORMANCE
REQUIRED MINIMUM SETBACKS:
FRONT 35'
SIDE 15'
REAR 50'
PROVIDED SETBACKS:
FRONT 283.13'
SIDE 251.53'
REAR 167.27'
TEMPORARY CLASSROOMS ARE ACCESSORY
TO THE EXISTING SCHOOL AND ARE
ALLOWED IN THE OVERALL SETBACK AREA.
BUILDING HEIGHT:
MAXIMUM HEIGHT 45'
PROPOSED HEIGHT 16'-8"
ADJACENT PROPERTY INFORMATION
1. FOX, GROVER T; PIN 74B-5 1-2; ZONING: RP; USE:
RESIDENTIAL
2. KULP, JOAN C; PIN 748-5 1-3; ZONING: RP; USE:
RESIDENTIAL
3. BENNETT, KAREN; PIN 74B-5 1-4; ZONING: RP; USE:
RESIDENTIAL
4. HINES, RALPH W & LYNDA K; PIN 74B-5 1-5; ZONING: RP;
USE: RESIDENTIAL
5. KEPLINGER, HARLAN C; PIN 74B-5 1-6; ZONING: RP; USE:
RESIDENTIAL
6. KEPLINGER, HARLAN C; PIN 74B-5 1-7; ZONING: RP; USE:
RESIDENTIAL
7. EMORY, CHARLES E JR & CHRISTINE; PIN 74B-5 1-8; ZONING:
RP; USE: RESIDENTIAL
8. MENDOZA, LARRY D & BEVERLY J; PIN 7413-5 1-9; ZONING:
RP; USE: RESIDENTIAL
9. MCMANIGLE, SETH D & JAIME L SOLENBERGER; PIN 748-5
1-10; ZONING: RP; USE: RESIDENTIAL
10. STEPHENSON, MICHAEL R & CHERYL A; PIN 74B-5 1-11;
ZONING: RP; USE: RESIDENTIAL
11. EARNSHAW, HERBERT I & RUTH M; PIN 74B-5 1-12; ZONING:
RP; USE: RESIDENTIAL
12. RYDER, KENNETH D & STEPHANIE B; PIN 74B-5 1-13; ZONING:
RP; USE: RESIDENTIAL
13. DRIVER, ERIN B & SLOANE, BRYAN E; PIN 74B-5 1-14;
ZONING: RP; USE: RESIDENTIAL
14. ASJODI, MIKE MEHDI & ASJODI, CAROLYN SUE; PIN 86 -A -5A;
ZONING: RP; USE: RESIDENTIAL
15. SHIFFLETT, RAY MARVIN; PIN 75-A-52; ZONING: RP; USE:
RESIDENTIAL
16. SHIFFLETT, RAY MARVIN; PIN 75-A-53; ZONING: RP; USE:
RESIDENTIAL
17. SALE, GARRY D TRUSTEE & ZEBULON B; PIN 74B-11 1-1;
ZONING: RP: USE: RESIDENTIAL
18. TALLEY, JANET DIANE; PIN 74B-11 1-2; ZONING: RP; USE
RESIDENTIAL
19. PEREIRA, JOSHUA LOUIS & ADELE MARIE; PIN 74B 11 1-3;
ZONING: RP; USE: RESIDENTIAL
20. KEVIN PATTON LLC; PIN 74B-11 1-4; ZONING: RP; USE:
RESIDENTIAL
21. LAYMAN, CYNTHIA J; PIN 748-11 1-5; ZONING: RP; USE:
RESIDENTIAL
22. MIDKIFF, EDWARD W & JASMINE R; PIN 74B-11 1-6; ZONING:
RP; USE: RESIDENTIAL
23. WYMER, CHRISTOPHER S; PIN 74B-11 1-7; ZONING: RP; USE:
RESIDENTIAL
24. SHERMAN, FORREST A & LINDA W; PIN 74B-11 1-8; ZONING:
RP; USE: RESIDENTIAL
25. BS RENTALS LLC; PIN 74B-11 1-9; ZONING: RP; USE:
RESIDENTIAL
26. COLE, ORAL JEREMIAH; PIN 7413-11 1-10; ZONING: RP; USE:
RESIDENTIAL
GENERAL NOTES
1. OWNER:
FREDERICK COUNTY SCHOOL BOARD
SUPERINTENDENT OF SCHOOLS
1415 AMHERST STREET
WINCHESTER, VA 22601
(540) 622-3888
2. ARCHITECT/ENGINEER:
OWPR, INC.
200 COUNTRY CLUB DRIVE
PLAZA ONE, BUILDING -E-
BLACKSBURG, VA 24060
(540) 552-2151 FAX (540) 951-0219
3. SITE AREAS:
TOTAL SITE AREA 23.90 ACRES
TOTAL DISTURBED SITE AREA 0.03 ACRES
4. ZONING: RESIDENTIAL PERFORMANCE (RP)
5. MAGISTERIAL DISTRICT: OPEQUON
6. BUILDING INFORMATION:
MOBILE UNITS HEIGHT: 1 STORY - 16'-8'
BUILDING USE: EDUCATIONAL
BUILDING AREA: 111,602 S.F. (EXISTING)
7,106 S.F. (TEMPORARY)
118,708 S.F. (TOTAL)
7. PROPERTY INFORMATION:
TAX PARCEL:- 75-A-54
CURRENT USE: ELEMENTARY SCHOOL
PHYSICAL ADDRESS: 901 AYLOR RD
STEPHENS CITY, VA 22655
8. CONTRACTOR SHALL HAVE A LICENSED LAND SURVEYOR RESET
ANY BENCHMARKS DISTURBED DURING CONSTRUCTION AND SHALL
NOTE THE NEW LOCATION AND ELEVATION ON THE AS -BUILT
DRAWINGS.
9. ALL EXISTING SITE FEATURES DAMAGED AS A RESULT OF THE
CONTRACTOR'S ACTIONS SHALL BE REPLACED OR REPAIRED AS
DIRECTED BY THE ARCHITECT/ENGINEER AT NO ADDITIONAL COST
TO THE OWNER.
10. A PRE CONSTRUCTION MEETING WILL BE HELD PRIOR TO
BEGINNING CONSTRUCTION.
11. IT IS THE CONTRACTOR'S RESPONSIBLILTY TO MEET COMPLIANCE
REQUIREMENTS WITH SECTION 59.1-406.ET.SEQ., OF THE CODE OF
VIRGINIA (OVERHEAD HIGH VOLTAGE LINES SAFETY ACT).
12. FREDERICK WATER PROJECT INFORMATION - NO CHANGE IN WATER
AND SANITARY SEWER DEMAND OR USAGE.
13. PREVIOUS APPROVED SITE PLANS INCLUDE:
- SITE PLAN (SP) #01-91.
14. NO PROPOSED CHANGES TO SITE SIGNAGE OR LANDSCAPING
INCLUDED IN THIS PROJECT.
15. NO PROPOSED BUILDING -MOUNTED OR POLE -MOUNTED SITE
LIGHTING INCLUDED IN THIS PROJECT.
SURVEY NOTES
1. TOPOGRAPHIC INFORMATION SHOWN HEREON IS BASED ON
FREDERICK COUNTY GIS DATA AND AERIAL PHOTOGRAPHY.
2. THE BOUNDARY INFORMATION WAS PREPARED WITHOUT THE
BENEFIT OF A TITLE REPORT.
3. ANY UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM
FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. THE
SURVEYOR MAKES NO GUARANTEES THAT THE UNDERGROUND
UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA,
EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER
DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN
ARE IN THE EXACT LOCATION INDICATED ALTHOUGH HE DOES
CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE
FROM INFORMATION AVAILABLE.
4. BOUNDARY DISTANCES AND BEARINGS PROVIDED WERE TAKEN
FROM EXISTING RECORD DRAWINGS AND HAVE NOT BEEN VERIFIED.
THIS PLAT DOES NOT CONSTITUTE A BOUNDARY SURVEY.
6 aCT
Hama,i �OmEd
c N
w
Z
w
0
z
/ a
V
u,
O �
x
V
J
0
fn
N
ro
m
O
o
U
z
Z
o
J
O
0
O
Q
�
I
C
(n
a
�
Q
d
OJ
U
N
a
Q
0
U
O
Q
N
J
U
I
m
0-
:2
U
Li
0
0
No. Description Date
Revisions
0
fn
N
ro
m
m
o
Z
o
�
a
�
E
C
3
L)p
N
r
CL
a
0
U
O
N
N
U
0
0
No. Description Date
Revisions
z
Q
J
0-
LLJ
J
J
Q
LLJ
O
fn
N
m
m
a
C
3
L)p
N
r
CL
a
0
U
Q
z
Q
J
0-
LLJ
J
J
Q
LLJ
O
p P U.
4 :,
L
1`
SITE PLAN NOTES
q�PVTH nF v
l
[
' 'fix
• : I
'1)� ; c.' " e
t
1.
ALL DIMENSIONS SHOWN ARE TO FACE OF BUILDING, FACE OF CURB, EDGE OF
AND PERPENDICULAR
WILLIAM A.SHELTON
Iµ
PAVEMENT, TO PROPERTY LINES.
Lia. No. 031657
-
f 4
(:_� 7 C'^1
! r.I
i;
2.
CONTRACTOR SHALL CONTACT "MISS UTILITY (800-552-7001 FOR MARKING OF
II V i
{.i
,
UTILITIES 72 HOURS PRIOR TO ANY EXCAVATION OR CONSTRUCTION.
I'_t
IMAN
_t'
3.
UTILITIES SHOWN ON THESE PLANS REPRESENT UTILITY LOCATIONS AS DETERMINED
orG
CONAL
I-I
(�' r4rj
j'1.
..-_.
FROM AERIAL PHOTOGRAPHY. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION
Y I (r'+•I rry
I'`—.._>
BK' 1F-
•�
I ••',=s•-,.,,;,
• '"
OF ALL UTILITY LOCATIONS, DEPTHS AND SIZES PRIOR TO CONSTRUCTION. IF EXISTING
Rob�.,
ilt <�
A��K
...:, _ e -.. �_� _ 4 "I _
_
::�_ _:,fir - ;;,. LL ,
,, .... -•
CONDn10NS ARE DIFFERENT THAN THAT WHICH IS SHOWN ON THE DRAWINGS, NOTIFY
,3„w
..V_•
II
I b. E� ,=,
THE ARCHITECT/ENGINEER IMMEDIATELY.
II
- F I
'._n,
4.
THERE MAY EXIST UTILITIES WHICH HAVE NOT BEEN SHOWN ON THE PLANS AND OF
8
'I 4`
��'�--1'_
-. -
--
I t I.E1 ;..- 'ceyc`
'- - —
_
_ e'- ,;y r, a, ('I '''
I
.I -�
WHICH THERE IS NO RECORD. IF ACTIVE UTILITIES ARE ENCOUNTERED WHICH WERE
=m�' � e
`-` '-' h. -`•....
j 7
! s »+r,r t'I
NOT INDICATED ON THE DRAWINGS, CONTRACTOR SHALL CONTACT THE APPROPRIATE
UTILITY COMPANY AND THE ARCHITECT/ENGINEER IMMEDIATELY. CONTRACTOR SHALL
a m a LL 33 �, a
,I
I („E=+z
aft 1 IRit.
ta';,
!
. _..
,r / �5.
_' if"di -
- _ -, - -� As�lcul.,=„
f.�
I `" , ..
TAKE NECESSARY STEPS TO RESTORE UTILITY SERVICE TO ANY DAMAGED UTILITIES AS
�+
r
i ,.
� "—t
I ,t
,I r I. ` �� ;. � ii' i•-
- �,; Irl ru«,ral �': Arlo-
III ,. : _.'. v
SOON AS POSSIBLE.
` �i ��
ac+a
w
cc Irmo 9 _ :.._li , t -=1
1;106 M + u,-,AoE
O
�
'-' U� t ,�
IS:CH^ larJFh�P-
'-!1,t :.
lI L
- {'
.-
5.
CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL UNDERGROUND UTILITIES
BEFORE COMMENCING WITH CONSTRUCTION.
z
k
-
- r, Lri i! a
PCU'TUcL
- 11
z
CLA§tiR'TOM
�
(I II
(
w
i
r+.'+�,`—"`"'
I�. o n^r
Is on,cs,L.. __ *.,'
,+ ---- - �-----"- -- ..
"
FH
-
6.
THERE SHALL BEARE CONSTRUCTION MEETING WITH THE CONTRACTOR,FklST
ARCHITECT/ENGINEER, THE OWNER PRIOR TO BEGINNING CONSTRUCTION.
p
EXIST BUS
7.
MODULAR TRAILER UNIT LENGTHS MAY INCREASE ONCE MATED TOGETHER.
CONTRACTOR SHALL ENSURE CANOPY AND RAMP SYSTEM UNE UP WITH DOUBLE DOOR
PROVIDE 1.'C. W/ PULLSTRNG
"�,-_PROPOSED CANOPY,
(2) BOLLARDS =
LOOP
AS SHOWN ON THE SITE PLAN.
ELEC NOTE 6ROM
(3' F FH)
COORD. Wf OWNER LL,
30' MIN
c� o COORDINATE EXACT LOCATION
•
'
8.
CONTRACTOR SHALL DISPOSE OF ALL SPOILS AND EXCESS MATERIAL OFFSITE, TO AN
O
(FIRE TRUCK PROVIDE 1"C FOR
= = w T OF PENETRATION WITH OWNER
4'--
MATCH FLUSH
APPROVED DUMP SITE.
a
ACCESS) SAS/FIRE ALARM,
PROVIDE 2"C FOR DATA MATCH
FLUSH
o z W/ EXIST
- Z ASPH PVMT
ELEC NOTE 3—
I FROM NEAREST CLASSROOM, W/ EXIST
--- --------57.50'---
-- _--E -... -.-.._109.33'
ELEC NOTE 4, 5 ASPH
PVMT------t50'----{--
(TYP)
`,...:
7'
(TYP)
ELECTRICAL NOTES
J
I_.--1'0. 3' DEEP
0 i� z
RAMP SHALL BE PROVIDED BY
CONCRETE FOOTING
(
PROVIDE PAVED FIRE
_
LANE ACCESS TO �`
1.
PROVIDE A ELECTRICAL SERVICE, PROVIDE A NEW SERVICE ENTRANCE RATED PANEL MDP:
0 F
MOBILE UNIT
MANUFACTURER
l
EXIST ASPH PVMT
1200 AMP, SINGLE PHASE, 240/120 VOLT PANEL WITH A 1200 AMP MCB. PROVIDE 8, 2 POLE,
= Z S
AND SHALL BE ADA ACCESSIBLE
RAMP SHALL BE PROVIDED BY
150 AMP BREAKERS TO FEED MODULARS. PROVIDE 3-1/0 CONDUCTORS AND 1—#6 GROUND IN
U
MOBILE UNIT MANUFACTURER
2131a CONDUIT FROM NEW PANEL MDP.
N :D
AND SHALL BE ADA ACCESSIBLE
.t
EXIST
TEMPORARY CLASSROOMS UNIT
2.
PROVIDE 1-20 AMP SINGLE POLE BREAKER TO FEED A CONVENIENCE RECEPTACLE LOCATED
w
ASPH PVMT
o .(6,695.11 TOTAL SF}
AT MOUNTING RACK. PROVIDE #12 WARE AND /12 GROUND TO CONNECT CIRCUIT.
J 0
(728.56 SF PER CLASSROOM)
_ _
3.
EXISTING FIRE ALARM SYSTEM IS LOCATED IN THE MAIN ELECTRICAL ROOM. COORDINATE EXACT
M O °O
`
LOCATION WITH OWNER. PROVIDE A NEW FIRE ALARM CONTROL PANEL IN MODULAR UNITS.
0 I
1'
PROVIDE RELAYS TO INTERFACE WITH EXISTING FIRE ALARM PANEL. EXISTING FIRE ALARM
N
REMOVE ASPH PVMT
SYSTEM IS ANALOG SYSTEM. ALL NEW DEVICES ARE TO BE FED FROM NEW FIRE ALARM PANEL
NECESSARY FOR CLASS
SROOM
LOCATED IN MODULAR TEMPORARY CLASSROOMS. ACTIVATION OF A FIRE ALARM DEVICE IN
N
UNIT INSTALLATION
EITHER BUILDING SHALL ACTIVATE NOTIFICATION DEVICES IN BOTH BUILDINGS.
or
-
4.
4.
PROVIDE FIBER FROM NEAREST DATA CLOSET TO NEW DATA SWITCH LOCATED IN TEMPORARY
O U
CLASSROOMS. COORDINATE WITH OWNER FOR FIBER CONNECTOR AND SIZE REQUIREMENTS.
_j rn
750
AMP PANEL
EXIST
/
i�l�,
-
5.
PROVIDE CONNECTIONS FOR EXISTING PUBLIC ADDRESS SYSTEM. EXISTING PUBLIC ADDRESS
Q
120/240 V, SINGLE PHASE
ASPH PVMT
,�y
.�----X-
HEADEND IS LOCATED IN THE MAIN OFFICE AREA. PROVIDE ADDITIONAL CARDS IN EXISTING
Q
(TYP OF 8)
„ {1
ZONEHEADEANDND T� CORRIDOR DOR AS EXPAND INDIVIDUAL TO M�ONE 8 NEW CLASSROOMS EACH AS AN INDIVIDUAL
J
6.
PROVIDE 7 UTHONIA, OFM LED P1 50K MVOLT DDB HP17 OR EQUAL LIGHTS MOUNTED ON
0 w
N
UX, BASKETBALL GOALS
TO BE REMOVED AS
/
UNDERSIDE OF CANOPY. EQUALLY SPACE LIGHTS ALONG CANOPY. CONNECT LIGHTS TO SPARE
20 AMP CIRCUIT IN PANEL LOCATED IN TEMPORARY CLASSROOM. PROVIDE A PHOTOCELL
MOUNTED ON TEMPORARY CLASSROOMS TO CONTROL FIXTURES. PROVIDE #10 WIRE AND /10
0
U
NECESSARY BY FOPS
I
`" Y
GROUND TO COMPLETE CIRCUIT.
(TMP)
REMOVE AND REPLACE /
PVMT
ASPH AS NECESSARY
FOR ELEC COP7D'UIT
EXIST MATCH EXISTING ASPHALT PAVEMENT SECTION
"yam 'u •-a w w ��.+,<44 �`"
PROVIDE 3 1/0 #6, 2'C
'
PVMT INCLUDING ANY INTERMEDIATE OR BASE COURSES.
r0 EACH PANEL
r'..
STL TROWEL FIN
Z o
_�
-
/ /
III
(TYP OF 6}
t -.�{r- -
SEALED CONIC
�
12" PATCH 12"
MIN WIDTH MIN
E
E o
RAPPA'iAtT'.vCE.A f!tJTR't TO /J
-.. _ --..
�� -�"`
PROV01E NEW T,tu1PORAR" POLE /-ELEC NOTE
!
1, 2 ,:.:.-�"-'-""� -�
n-.
CJ
N
AND POWER FROM ACROSS ROAD
\•,
��
6"0 SCH 40
,._ --�---' _ -k- "` STL PIPE W/
.: ..:,.
CONIC FILL
(PAINT)
3 3
PROVIDE
MOUNTING RACK
r'"
r;r r
. .
SAWCUj
_----rE
WITH COMPONENTS
w
AS -
a.--
PVMT EDGE ED VDOT
SHOWN IN
DETAIL
,
u`
1- ( MIN)
21-A (1
A 18" IN
IN)
mw
� 'o
t
—
N
P1
0
r
ftD
G
OHt
=
PAT
PAVEME DETAIL
NTNG
a
RAPP Et.E
'`" :.`. ..,>E....I. ;,
......:
CONCRETE
a
p p U Q
�-- TkpHE
: �"""" x.•
-
TOP
SCALE�N
... t ..
"_. •
-
PANEL MDP
PROVIDE RACK
"
MEMBERS WITH
COMPRESSIBLE
o
o
TAPPING HOLES FOR
JOINT FILLER
PROVIDE
RACK POSTS CONSTRUCTED
°o
o
BRACKETS
OF 12
GAUGE GALVANIZED STEEL
°
°
BEAMS WITH TAPPED HOLES FOR
°o
°
CT CABINET
CII
.a.
-
BRACKETS IN 2 FEET OF CONCRETE
°
II II
I I I I
II II
I I
o
METER MOUNTED
J
.a.
o
o
TO OPPOSITE SIDE
Q
Z
OF CT CABINET
o
ALL CONNECTIONS
°
LLJ
°
3/4"0 in
SHALL BE WIELDED
°o
Q
Y0'
WELDED KEY
o
°
oJCONVENIENC
_
PROVIDE HORIZONTAL MEMBERS OF°°7.5'---}�7.5':L12 GAUGE GALVANIZED STEEL WITH
°
°NOlEP2ACLE,
Z
2" ASPHALT
M
TAPPED HOLES FOR BRACKETS
°o
°o
Q
SURFACE COURSE
o
°o
GRADE
VDOT SM -9.5A
-
°
°
°
°
Z
1/4":1' SLOPE
KEYa
Q
CONCRETE FOOTING .ju, I I".
8" AGGREGATE
1'- "
(4,000 PSI)
BASE COURSE
vDOT 21-B
CONCH
LLJ
-� 24"
COMPACTED
SUBGRADE
BOLLARD DETAIL
N
FIRE LANE SECTION
MOUNTING RACK
NO
SCALE
NO SCALE
NO SCALE
SITE PLAN
D
1"
20' 10' 0 20' 40'
= 20'-0"
V 1 O2
No.
Description
Date
Revisions
4 �
I I
I I
I
I I
I I
I I
II (1I
® y
I I
I I
� I
I I
I
I
II II
TOTAL MODULAR UNIT - 6,695.11 SF
I I
I
DATA DROP DATA DROP DATA DROP DATA DROP
I
CLASSROOM CLASSROOM
(728.56 SF) (728.56 SF)
CLASSROOMIE CLASSROOM
(728.56 SF) WIRELESS (728.56 SF) WIRELESS
ACCESS ACCESS I I
POINT POINT
II
I
DATA DROP DATA DROP DATA DROP DATA DROP
CEILING MOUNTED
NETWORK CLOSET
I
CONDUIT FOR
NETWORK CABLES
IP CAMERA
I
DATA DROP f DATA DROP DATA DROP DATA DROP
CLASSROOM CLASSROOM
(728.56 SF) (728.56 SF)
WAP (728.56
WAP(728.56CLASSROOM
(728.56 SF)
PROVIDE CONDUIT WITH PULL WIRELESS WIRELESS
CHORDS FROM DATA BOX TO ACCESS ACCESS
ABOVE CORRIDOR CEILING, TIP POINT POINT
DATA DROP DATA DROP DATA DROP DATA DROP
lr= V V V V V V
CORNER MOUNTED
IP CAMERA
CORNER MOUNTED
IP CAMERA
i
MODULAR UNIT ELECTRICAL PLAN 0 -
ZL
SCALE: 1.5" = 1 FOOT 0
0
No. Description Date
Revisions
m
J
0
N
^o
o
a
E
E
O
U
�
�
0
N
�
Z
s
Cl )
=D
d
m
0
0
(n
s
n
�
(n
Q
a
OJ
U
N
Q
<
Of
Q
(�
C
x
U
CL
N
LL -
0
Z
0
N
^o
o
a
E
E
O
U
�
�
0
N
C103
N
N
m
3
3
d
m
0
3
s
n
aN
(�
Q
C103
m
N
1
N