Loading...
HomeMy WebLinkAbout05-17 Site PlanSITE NOT FOR CONSTRUCTION CS0001 BY NO . DA T E RE V I S I O N S IN T E R S T A T E T R U C K S E R V I C E , I N C . 14 7 R Y C O L A N E WI N C H E S T E R V A 14 7 R Y C O L A N E WI N C H E S T E R , V A 2 2 6 0 2 C. W I L S O N & L I N D A W . F L E T C H E R CO V E R S H E E T FLTC1601 AS NOTED MMA MMA SHEET OF1 5 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PREPARED FOR: OWNER/DEVELOPER C. WILSON & LINDA W. FLETCHER 147 RYCO LANE WINCHESTER, VA 22602 (540) 722-1001 INTERSTATE TRUCK SERVICE, INC. ¬ SITE PLAN SP#05-17 ¬ SHAWNEE DISTRICT, FREDERICK COUNTY JANUARY 27, 2017 REVISED MARCH 16, 2017 REVISED MARCH 28, 2017 LOCATION MAP Scale: 1" = 2000' 2 0 1 7 - 0 2 - 0 8 1 3 ( 5  3 / $ 1 1 , 1 *  & 2 0 0 ( 1 7 6 MM A 20 1 7 - 3 - 1 6 2 $ ' ' ( '  : $ 7 ( 5 / , 1 (   3 5 2 ) , / ( J D S 2 0 1 7 - 0 3 - 2 8 3 R E V I S E D P E R F C S A C O M M E N T S J D S CALL 1-800-552-7001 CALL BEFORE YOU DIG ALWAYS CALL 811 BEFORE YOU DIG IN VIRGINIA SECTION 56-265.17 REQUIRES THREE WORKING DAYS NOTICE TO UTILITIES BEFORE YOU EXCAVATE, DRILL OR BLAST VIRGINIA UTILITY PROTECTION SERVICE, INC. TICKET NUMBER(S):  PREPARED BY: PENNONI ASSOCIATES INC. 117 East Piccadilly Street Winchester, VA 22601 T 540.667.2139 F 540.665.0493 APPROVED BY FREDERICK COUNTY ZONING ADMINISTRATOR OWNER C. WILSON FLETCHER & LINDA W. FLETCHER 147 RYCO LANE WINCHESTER, VIRGINIA 22602 Sheet List Table Sheet Number Sheet Title 1 Cover Sheet 2 ORIGINAL SITE PLAN 3 Site Plan 4 WATERLINE PLAN AND PROFILE 5 MISCELLANEOUS DETAILS RE V I S E D P E R F . C . S . A . 4 20 1 7 - 1 4 - 1 7 JD S REVISED APRIL 14, 2017 NOT FOR CONSTRUCTION CS1002 BY NO . DA T E RE V I S I O N S IN T E R S T A T E T R U C K S E R V I C E , I N C . 14 7 R Y C O L A N E WI N C H E S T E R V A 14 7 R Y C O L A N E WI N C H E S T E R , V A 2 2 6 0 2 C. W I L S O N & L I N D A W . F L E T C H E R OR I G I N A L S I T E P L A N FLTC1601 1"=40' MMA MMA SHEET OF2 5 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 40'80' NO R T H PE N N O N I A S S O C I A T E S I N C . 2 0 1 7 - 0 2 - 0 8 1 3 ( 5  3 / $ 1 1 , 1 *  & 2 0 0 ( 1 7 6 MM A 20 1 7 - 0 3 - 2 8 2 5 ( 9 , 6 ( '  3 ( 5  ) & 6 $  & 2 0 0 ( 1 7 6 J D S 2 0 1 7 - 0 4 - 1 4 3 R E V I S E D P E R F C S A J D S                 NOT FOR CONSTRUCTION CS1001 BY NO . DA T E RE V I S I O N S IN T E R S T A T E T R U C K S E R V I C E , I N C . 14 7 R Y C O L A N E WI N C H E S T E R V A 14 7 R Y C O L A N E WI N C H E S T E R , V A 2 2 6 0 2 C. W I L S O N & L I N D A W . F L E T C H E R SI T E P L A N FLTC1601 AS NOTED MMA MMA SHEET OF3 5 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 40'80' NO R T H TM #64-10-1 Fredericktown Group LC DB 955 Pg 152 NOTES: 1.NO NEW EMPLOYEES ARE PROPOSED AS A RESULT OF THIS ADDITION. NO EXISTING PARKING AREAS WILL BE IMPACTED BY THE ADDITION AND NO ADDITIONAL PARKING IS PROPOSED. 2.NEW BUILDING ADDITIONS ARE REPLACING EXISTING GRAVEL AREAS THEREFORE THERE IS NO INCREASE IN IMPERVIOUS AREAS. 3.NO STORMWATER MANAGEMENT FACILITIES ARE PROPOSED. 4.NO NEW SIGNAGE IS PROPOSED. 5.NO NEW SITE LIGHTING OR BUILDING MOUNTED LIGHTING IS PROPOSED. 6.NO DUMPSTER IS PROPOSED. 7.*PROPOSED FENCE SHALL BE 100% OPAQUE VINYL TARP WITH CHAIN LINK. CHAIN LINK FENCE WITH SLATS IS NOT ALLOWED. PROJECT SUMMARY NO NEW EMPLOYEES ARE PROPOSED AS A RESULT OF THIS ADDITION. NO EXISTING PARKING AREAS WILL BE IMPACTED BY THE ADDITION AND NO ADDITIONAL PARKING IS PROPOSED. 2 0 1 7 - 0 2 - 0 8 1 3 ( 5  3 / $ 1 1 , 1 *  & 2 0 0 ( 1 7 6 MM A 20 1 7 - 3 - 1 6 2 $ ' '  : $ 7 ( 5 / , 1 (  $ 1 '  ) , 5 (  + < ' 5 $ 1 7 6 J D S 2 0 1 7 - 0 3 - 2 8 3 R E V I S E D P E R F C S A J D S 2 0 1 7 - 0 4 - 1 4 4 5 ( 9 , 6 ( '  % <  ) & 6 $ J D S             PROPOSED FDC FIRE DEPT. CONNECTION PROPOSED 6" CL52 D.I. WATER LINE PROPOSED 8" CL52 D.I. WATER LINE PROPOSED 20' F.C.S.A. EASEMENT 16"X8" WET TAP BY F.C.S.A. EX. HANDICAP PARKING SIGN 8.0' 8.0' 20.0'STRIPE FOR HANDICAP PARKING FIRE HYDRANT "B" PROTECTED BY 4 6" BOLLARDS FENCE CONTRACTOR SHALL COORDINATE FENCE AND GATE LOCATION WITH F.C.S.A. INSPECTOR. HY D NOTE: ACTUAL LOCATION OF EXISTING WATER AND SEWER SERVICE AND ANY OTHER UNDERGROUND UTILITIES IS UNKNOWN AND MUST BE DETERMINED PRIOR TO CONSTRUCTION. ANY CONFLICTS SHALL BE REPORTED TO F.C.S.A. AND ENGINEER FOR RESOLUTION. MINIMUM OF 18" SEPARATION IS REQUIRED. PROPOSED SCREENED CHAIN LINK FENCE PROPOSED 852 S.F. ADDITION PROPOSED 20' F.C.S.A. EASEMENT 1-8" X 6" TEE 1- 6 " G.V. 1-8" X 6" TEE 1- 6 " G.V. 1 FULL JT. 8" CL52 D.I.P. 1-8" G.V. 1-CAP W/FLUSHING ASS'Y. 1-6" X 6" TEE 1- 6 " G.V. FIRE HYDRANT "C" PROTECTED BY 4 6" BOLLARDS LIMITS OF DISTURBANCE LIMITS OF DISTURBANCE ARE TO BE ENCLOSED WITH SILT FENCE PROPOSED 6" CL52 D.I. WATER LINE PROPOSED FIRE LINE ;ƒ BEND;ƒ BEND 1-8" X 11 1 4ƒ BEND PROP. 15.0' FCSA EASEMENT NOT FOR CONSTRUCTION CS1701 BY NO . DA T E RE V I S I O N S IN T E R S T A T E T R U C K S E R V I C E , I N C . 14 7 R Y C O L A N E WI N C H E S T E R V A 14 7 R Y C O L A N E WI N C H E S T E R , V A 2 2 6 0 2 C. W I L S O N & L I N D A W . F L E T C H E R WA T E R L I N E P L A N A N D P R O F I L E FLTC1601 AS NOTED MMA MMA SHEET OF4 5 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 30'60' NO R T H 2 0 1 7 - 0 2 - 0 8 1 3 ( 5  3 / $ 1 1 , 1 *  & 2 0 0 ( 1 7 6 MM A 20 1 7 - 3 - 1 6 2 $ ' '     : $ 7 ( 5 / , 1 (   ) , 5 (  + < ' 5 $ 1 7 6 J D S 2 0 1 7 - 3 - 2 8 3 R E V I S E D P E R F C S A J D S 20 1 7 - 4 - 1 4 4 RE V I S E D P E R F C S A J D S             ABBREVIATION DEFINITION CONCRETE POST FIRE HYDRANT GUY ANCHOR GAS METER INVERT METAL POST POLYVINYLCHLORIDE PIPE TELEPHONE CONTROL BOX WOOD LIGHT POLE WATER METER WOOD POWER POLE WATER VALVE LEGEND U/G WATER LINE U/G TELEPHONE LINE U/G GAS MAIN EXISTING ADA PARKING & SIGN (NOT STRIPED) PROPOSED FIRE HYD. "B" NOTE: ACTUAL LOCATION OF EXISTING WATER AND SEWER SERVICE AND ANY OTHER UNDERGROUND UTILITIES IS UNKNOWN AND MUST BE DETERMINED PRIOR TO CONSTRUCTION. ANY CONFLICTS SHALL BE REPORTED TO F.C.S.A. AND ENGINEER FOR RESOLUTION. MINIMUM OF 18" SEPARATION IS REQUIRED.PROPOSED FIRE HYD. (C) FOR F.D.C. PROPOSED FIRE LINE F.D.C. CONNECTION ON BUILDING. BACKFLOW PREVENTER, 6" FIRELINE METER, POST VALVE INDICATOR ALL INTERNAL TO BUILDING. PROPOSED 6" ;ƒ%(1' PROPOSED 6" ;ƒ%(1' 1-6"X6" TEE 1 - 6" G.V. 1 FULL JT. 8" D.I. PIPE 1 8" GATE VALVE CAP W/FLUSHING ASS'Y. NOT FOR CONSTRUCTION CS1702 BY NO . DA T E RE V I S I O N S IN T E R S T A T E T R U C K S E R V I C E , I N C . 14 7 R Y C O L A N E WI N C H E S T E R V A 14 7 R Y C O L A N E WI N C H E S T E R , V A 2 2 6 0 2 C. W I L S O N & L I N D A W . F L E T C H E R MI S C E L L A N E O U S D E T A I L S FLTC1601 AS NOTED MMA MMA SHEET OF5 5 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 2 0 1 7 - 0 2 - 0 8 1 3 ( 5  3 / $ 1 1 , 1 *  & 2 0 0 ( 1 7 6 MM A 20 1 7 - 3 - 1 6 2 $ ' '     : $ 7 ( 5 / , 1 (   ) , 5 (  + < ' 5 $ 1 7 6 J D S 2 0 1 7 - 3 - 2 8 3 R E V I S E D P E R F C S A J D S 20 1 7 - 0 4 - 1 4 4 R E V I S E D P E R F C S A J D S