HomeMy WebLinkAbout07-17 Comments (2)Tyler Klein From: Tyler Klein Sent: Tuesday, May 09, 2017 3:07 PM To: 'Jeremy Tweedie' Subject: RE: Cb Ventures Jeremy, thank you for the opportunity to review the resubmission. It appears all of the Planning & Development staff comments have been addressed. In regards to the request for Health Department comments, this is a result of the proposed restaurant us, which we typically request a comment from VDH . The request for GIS comments was tied to the subdivision comment from our first comment letter; given this is to remain a single lot and not going to be subdivided, there is no need for GIS comments/assigning separate addresses. As requested, provide final comments/approval from VDOT and an agency comment from the Health Department with the final submission. For the final submission, please provide at least five (5) hard copies, with a signed seal, for signature by the Zoning Administrator. Please also provide a PDF copy on a disk for the project file. Should you have any additional questions, please do not hesitate to get in touch. M. Tyler Klein, AICP Planner Department of Planning & Development Frederick County, Virginia 107 N. Kent Street Winchester, VA 22601 (540)722-8248 tklein(dfcva.us From: Jeremy Tweedie[mailto:jtweedie@greenwayeng.com] Sent: Tuesday, May 09, 2017 1:36 PM To: Tyler Klein Subject: Cb Ventures Importance: High Tyler At your convenience can you click on the link below and download and/or view the revised plan to ensure we addressed your comments from the March 23`d letter. https://file.ac/ixAxacBtfX4/ 1. Sealed Plans....will be provided at time of final county signature 2. Conformance with Rezoning #05-06 ...... previously provided letter and county approved. 3. Interstate IA Overlay..... no sign detail at this time, proposed location provided on site refer to sheet 10 & 11, additionally note provide on sheet 2 4. Dumpster Area.....details provided on sheet 15 5. Outdoor Lighting..... Note provided sheet 26 & 27 6. Agency Approval.... See attached.... Do we have to submit to GIS and Health Department? Don't typically just wondering why this one? Still awaiting VDOT COUNTY of FREDERICK Department of Planning and Development 540/ 665-5651 Fax: 540/ 665-6395 March 23, 2017 Jeremy Tweedie Greenway Engineering, Inc. 151 Windy Hill Lane Winchester, VA 22601 Re: 2"d Review Comments for Site Plan #07-17, CB Ventures — Commercial Development Property Identification Number (PIN): 43 -A -48A Dear Mr. Tweedie: Planning Staff has reviewed the above -referenced site plan resubmission, dated March 20, 2017, in response to Staff's comments dated February 10, 2017 to determine if administrative approval can be granted. At this time, administrative approval cannot be granted. This site plan will not be approved until the issues in this letter, as well as all issues of the other review agencies, have been adequately addressed. Please review Staff's comments listed below and then prepare a revised site plan which adequately addresses each concern. Review Comments: 1) Signed Seal. A signed seal of the certified Virginia land surveyor, architect, or engineer who prepared the site plan is required on final copies for signature by the Zoning Administrator. 2) Conformance with Rezoning #05-16. Per previous correspondence, Staff will not approve building permits until documentation demonstrating conformance with Proffer D have been provided. Actions required under Proffer D should be undertaken within 30 - days of site plan approval. 3) Interstate Area (IA) Overlay. Please provide the details (size, height, location) of any proposed interstate overlay sign, as applicable, and as consistent with Section 165-704.05 of the Zoning Ordinance. If no IA sign is to be provided, please add a note to this effect. 4) Dumpster Areas. Include details regarding screening/fencing of the outdoor dumpsters. These should be completely screened from view via a six-foot tall board -on -board fence, wall, berm, or evergreen screen. 5) Outdoor Lighting. Add a note that all lighting will conform to Section 165-201.07, Outdoor Lighting Standards, of the Frederick County Zoning Ordinance, and will be full cutoff on Sheet 25. 6) Agency Approvals. Comment sheets (approvals) are required from the following agencies: the Frederick County Inspections Department, the Frederick County Fire 107 North Kent Street, Suite 202 • Winchester, Virginia 22601-5000 Re: SP #07-17, CB Ventures — Commercial Development; 2"d review March 23, 2017 Page 2 Marshal, the Frederick County Sanitation Authority (FCSA), the Virginia Department of Transportation (VDOT), the Virginia Department of Health, the Frederick County Geographic Information Systems (GIS) Department, and the Frederick County Engineer. After you have revised the site plan, please resubmit one (1) copy so that Staff may verify the information contained on the plan addresses the above comments. Staff will also need all approved review agency comment sheets and at least five (5) copies of the final plan for approval and a digital (PDF) copy. Do not hesitate to contact me if you have any questions or concerns regarding this letter. Thank you for your consideration. Sincerely, M. Tyler Klein, AICP Planner MTK/pd cc: CB Ventures, 415 W. Cecil Street, Winchester, VA 22601 51 Windy Hill Lane Winchester, VA 22602 FNGINEERING March 20, 2017 Frederick County Department of Planning and Development 107 North Kent Street, Suite 202 Winchester, VA 22601 Attn: M. Tyler Klein, AICP Re: CB Ventures — Commercial Development — Site Plan #07-17 Comment Response Letter Dear Mr. Klein: We are in receipt of Planning comments dated February 10, 2017 and offer the following responses: Comments from Frederick County Planning Comment 1: Site Plan Reference Number. Add the Site Plan (SP) #07-17, to the cover sheet. Response: Revised as noted. Comment 2: Subdivision. If land bays (Units 1, 2, & 3) are planned to be on a separate lots, the plats for the lot needs to be approved and recorded prior to final site plan approval. The site plan should show the new lot layout, and copies of the recorded plats should be submitted for the project file. A note should be added to this effect. Response: See attached recorded documents. Comment 3: Previous Approvals. Note all previous approvals relating to the subject property including Rezoning #05-16. A separate plan sheet should be provided which includes the approved Proffer Statement from the Rezoning Application. Response: Revised as noted. Comment 4: Conformance with Rezoning #05-16. Ensure conformance throughout the site plan with the approved Proffer Statement including: Label all improvements outlined the approved Proffer Statement, • Amoco Lane pavement upgrades should be shown on the applicable plan pages (Proffer B-1); • On Sheet 11, note the inter -parcel ingress/egress easement with the adjoining property, and that it will be recorded prior to issuance of the Certificate of Occupancy Permit associated with this site plan. If the easement is already in place, provide the legal reference (Proffer B-2); and • Provide for review a draft letter to adjacent property owners regarding the "Off -Site Residential Buffer" (Proffer D). This draft letter should also be included on the plan sheet with the approved Proffer Statement. Owners who request the "Off -Site Residential Buffer" must be confirmed, and the buffer will need to be show on the plan set prior to final site plan approval. Response: Reference notes delineated on the site plan for the above proffers. Engineers Surveyors Planners Eavironraental Scientists L.ateratory ielephere 540-6624185 Pax 540-722-9528 wv, w.greenwayeng core File #2022QJNT/cls Comment 5: Interstate Area Overlay. Per the approved Rezoning this property also has an existing IA (Interstate Area Overlay) District designation which permits one (1) interstate overlay sign. IA Overlay signs are permitted for hotels, restaurants and gasoline stations. Please provide the details (size, height, location) of any proposed interstate overlay sign, as applicable, and as consistent with Section 165-704.05 of the Zoning Ordinance. Response: Noted provided on sheet 2. Comment 6: Proiect Information. Under "Project Information " on Sheet 2 the following items should be revised: • Revise the "Project Site Area" and "Disturbed Area, " as the total project site is 1.87 acres as listed in the County's GIS; • Add under "Current Zoning" that the property is also within the "Interstate Area Overlay (IA)" District, • Revise "Current Use" to "Vacant/Unoccupied; " • Revise "Proposed Use" to "Hotel/Restaurant with Drive-Thru and Retail/Commercial; " • Revised "Required Setbacks — Side" to "N/A; " • Revise the "Maximum Building Height" to 35 feet (FT) as permitted in the B2 (General Business) Dimensional and intensity requirements. Add a note under "Maximum Building Height" specifying the hotels in the B2 District may be up to 60 FT (Section 165-201.03(6), Height limitations: exemptions); • Under "Signs, " add a note that any proposed building mounted signage will be reviewed and approved at time of building permit, and • Provide the required number of loading spaces (1) and those proposed. Label the proposed loading space(s) on the applicable sheets. Response: Revised as noted Comment 7: Outdoor Lighting. Please provide a Photometric (Lighting) Plan and Lighting Plan Details sheets for review by Staff. Please ensure it fulfills requirements outlined in the Zoning Ordinance. Add a note that all lighting will conform to Section 165-201.07, Outdoor Lighting Standards, of the Frederick County Zoning Ordinance, and will be full cutoff. A table showing minimum, maximum, and average illumination should also be provided for review. Specify the height of all light fixtures (pole and building -mounted). Response: Refer to Site Lighting sheets. Comment 8: Open Space. On Sheet 14 distinguish the proposed open space using shading or hatching. Response: 25% Landscape area calculation and delineated is provided, refer to sheet 2 and 15. Comment 9: Agency Approvals. Comment sheets (approvals) are required from the following agencies: the Frederick County Inspections Department, the Frederick County Fire Marshal, the Frederick County Sanitation Authority (FCSA), the Virginia Department of Transportation (VDOT), the Virginia Department of Health, the Frederick County Geographic Information Systems (GIS) Department, and the Frederick County Engineer. Response: Noted and will provide upon receiving. File #2022C/JNT/cls Additional Staff Recommendations Comment 10: Additional Landscaping. Staff recommends additional landscape screening (evergreen trees) around the proposed outdoor trash receptacles. This will further enhance the landscaping on- site. Response: Will have client acknowledge request. Comment 11: Architecture & Design. Staff recommends inclusion of any architectural renderings and/or building elevations for the project file, as applicable. Response: Will have client acknowledge request. General Comment: After you have revised the site plan, please resubmit one (I) copy so that Staff may verify the information contained on the plan addresses the above comments. Staff will also need all approved review agency comment sheets and at least five (S) copies of the final plan for approval and a digital (PDF) copy. Response: Acknowledged. Thank you for your assistance with this project. Contact us with any questions or need for additional information. Sincerely, Greenway Engineering, Inc. Jeremy N. Tweedie Enclosures File #20220/JNT/cls COUNTY of FREDERICK Department of Planning and Development 540/ 665-5651 Fax: 540/ 665-6395 February 10, 2017 Jeremy Tweedie Greenway Engineering, Inc. 151 Windy Hill Lane Winchester, VA 22601 Re: Review Comments for Site Plan #07-17, CB Ventures — Commercial Development Property Identification Number (PIN): 43 -A -48A Dear Mr. Tweedie: Planning Staff has reviewed the above -referenced site plan to determine if administrative approval can be granted. At this time, administrative approval cannot be granted. This site plan will not be approved until the issues in this letter, as well as all issues of the other review agencies, have been adequately addressed. Please review Staff's comments listed below and then prepare a revised site plan which adequately addresses each concern. Review Comments: 1) Site Plan Reference Number. Add the Site Plan (SP) #07-17, to the cover sheet. 2) Subdivision. If land bays (Units 1, 2, & 3) are planned to be on a separate lots, the plats for the lot needs to be approved and recorded prior to final site plan approval. The site plan should show the new lot layout, and copies of the recorded plats should be submitted for the project file. A note should be added to this effect. 3) Previous Approvals. Note all previous approvals relating to the subject property including Rezoning #05-16. A separate plan sheet should be provided which includes the approved Proffer Statement from the Rezoning Application. 4) Conformance with Rezoning #05-16. Ensure conformance throughout the site plan with the approved Proffer Statement including: • Label all improvements outlined the approved Proffer Statement; • Amoco Lane pavement upgrades should be shown on the applicable plan pages (Proffer B-1); • On Sheet 11, note the inter -parcel ingress/egress easement with the adjoining property, and that it will be recorded prior to issuance of the Certificate of Occupancy Permit associated with this site plan. If the easement is already in place, provide the legal reference (Proffer B-2); and • Provide for review a draft letter to adjacent property owners regarding the "Off - Site Residential Buffer" (Proffer D). This draft letter should also be included on 107 North Kent Street, Suite 202 • Winchester, Virginia 22601-5000 Re: SP #07-17, CB Ventures — Commercial Development February 10, 2017 Page 2 the plan sheet with the approved Proffer Statement. Owners who request the "Off -Site Residential Buffer" must be confirmed, and the buffer will need to be show on the plan set prior to final site plan approval. 5) Interstate Area Overlay. Per the approved Rezoning this property also has an existing IA (Interstate Area Overlay) District designation which permits one (1) interstate overlay sign. IA Overlay signs are permitted for hotels, restaurants and gasoline stations. Please provide the details (size, height, location) of any proposed interstate overlay sign, as applicable, and as consistent with Section 165-704.05 of the Zoning Ordinance. 6) Project Information. Under "Project Information" on Sheet 2 the following items should be revised: • Revise the "Project Site Area" and "Disturbed Area," as the total project site is 1.87 acres as listed in the County's GIS; • Add under "Current Zoning" that the property is also within the "Interstate Area Overlay (IA)" District; • Revise "Current Use" to "Vacant/Unoccupied;" • Revise "Proposed Use" to "Hotel/Restaurant with Drive-Thru and Retail/Commercial;" • Revised "Required Setbacks — Side" to "N/A;" • Revise the "Maximum Building Height" to 35 -feet (FT) as permitted in the B2 (General Business) Dimensional and intensity requirements. Add a note under "Maximum Building Height" specifying the hotels in the B2 District may be up to 60 FT (Section 165-201.03(6), Height limitations: exemptions); • Under "Signs," add a note that any proposed building mounted signage will be reviewed and approved at time of building permit; and • Provide the required number of loading spaces (1) and those proposed. Label the proposed loading space(s) on the applicable sheets. 7) Outdoor Lighting. Please provide a Photometric (Lighting) Plan and Lighting Plan Details sheets for review by Staff. Please ensure it fulfills requirements outlined in the Zoning Ordinance. Add a note that all lighting will conform to Section 165-201.07, Outdoor Lighting Standards, of the Frederick County Zoning Ordinance, and will be full cutoff. A table showing minimum, maximum, and average illumination should also be provided for review. Specify the height of all light fixtures (pole and building -mounted). 8) Open Space. On Sheet 14 distinguish the proposed open space using shading or hatching. 9) Agency Approvals. Comment sheets (approvals) are required from the following agencies: the Frederick County Inspections Department, the Frederick County Fire Re: SP #07-17, CB Ventures — Commercial Development February 10, 2017 Page 3 Marshal, the Frederick County Sanitation Authority (FCSA), the Virginia Department of Transportation (VDOT), the Virginia Department of Health, the Frederick County Geographic Information Systems (GIS) Department, and the Frederick County Engineer. Additional Staff Recommendations 10) Additional Landscaping. Staff recommends additional landscape screening (evergreen trees) around the proposed outdoor trash receptacles. This will further enhance the landscaping on-site. 11) Architecture & Design. Staff recommends inclusion of any architectural renderings and/or building elevations for the project file, as applicable. After you have revised the site plan, please resubmit one (1) copy so that Staff may verify the information contained on the plan addresses the above comments. Staff will also need all approved review agency comment sheets and at least five (5) copies of the final plan for approval and a digital (PDF) copy. Do not hesitate to contact me if you have any questions or concerns regarding this letter. Thank you for your consideration. Sincerely, M. Tyler Klein, AICP Planner MTK/pd Attachment cc: CB Ventures, 415 W. Cecil Street, Winchester, VA 22601