Loading...
HomeMy WebLinkAbout03-18 CommentsREQUEST FOR SITE PLAN COMMENTS Frederick County Inspections Department Comment Mail to: Frederick County Inspections Department Attn: Building Official 107 North Kent Street, Winchester, Virginia 22601 Hand deliver to: Frederick County Inspections Dept. 107 North Kent Street, 2nd Floor Winchester, Virginia 22601 Phone: (540) 665-5650 Applicant: It is your responsibility to complete this form as accurately as possible in order to assist the agency with their review. Please attach two (2) copies of the Site Plan with this sheet Applicant's Name: GreyWolfe, Inc. - Gary R. Oates, LS -B, PE Telephone: 540-667-2001 Mailing Address: 1073 Redbud Road Winchester, Virginia, 22603 Name of development and/or description of the request: WCS - Brooke Road Facility - Freezer Warehouse Addition Location of Property: RECEIVED 188 Brooke Road, Brooke Road, Winchester, Virginia, 2603 a -r�tic►cGoyi�hh .. - Inss�pections Department Comments: ` \ ON p�fa,ita Inspections -FREDERICK COUNTY INSPECTIONS DEPARTMENT USE ONLY - Date Received 2 S 1 Review Number 3 4 5 (circle one) Date Reviewed 2 I Revision Required f4b_ _ Date pproved 2 g Signature & Date: z ** Please Return Form to Applicant** 18 Jj �J Buildings shall comply with The Virginia Uniform Statewide Building Code (VUSBC) Sections 311, S Storage of the International Building Code/2012, the 2012 VUSBC/ International Fire Code. Other Code that applies is ICC A117.1-3-09. Accessible and Usable Buildings and Facilities and 2012 Virginia Energy Code Proposed unlimited area facilities shall meet Section 507, Unlimited Area Buildings and maintain an open perimeter of 60. Addition and detached accessory structures shall maintain same type of construction. Addition shall not create any noncomformance with the existing building and the emergency exit requirements. Maximum travel distance per IBC/USBC to an exit is 400'. All required exits shall meet ANSI A117.1-09 for accessibility and slopes. Ramps shall be designed and constructed per ANSI A 117.1-09. Maximum travel distance to restrooms shall be in accordance with Section 2902.3.2. Storage racks exceeding 12' in height require fire department access around perimeter of the building and shall comply with the 2012 Virginia Fire Code/International Fire Code. Access doors provided at 100' ANSI parking spaces provided as required per T1106.1. Accessible parking and unloading shall not exceed 2% slope (1:48). Van spaces require minimum unloading area 8' with 8' of parking or a minimum of I V wide parking with 5' of unloading space is required. No enlargement provided. Accessible route with max 5% slopes shall be provided from parking/unloading to main entrance. Public entrances into spaces larger than 3000 sq ft shall be provided with a vestibule as detailed per ANSI A117.1-09 All structural plans submitted for permit application shall be sealed by a VA Design Professional Special inspection requirements of Chapter 17 of IBC shall apply to this type of structure. (soils, compaction, concrete, steel etc.) Geotech report is required per Uniform Statewide Building Code, Section 1803 s:\site plan comments\20121storage, brooke road greywolfe.doc RFQL-ESI FOW-Alf. PLAN CUNINIEN"Is Fr-cdclick Colluty Public NN orks Commen t 1'iail tri: Hand ddiver to: W 107 .07 \o,lh Wl i i i I i k-0 c r, V 1 r! i! V.i o ne 6 Aimplivatit- It i-, -ow ssihlc in i•l: -k n A i•, r MV-, lre7 - G.vv E M.ailiriw Atdr,,-v,: Rnad liOnnNar,ter, V-nima VICS - Thor**. Raw: FRrvjv - 1'repver Wa ri rs oi,F.P, A " ftxl, Brorke R'Arnt.coctpr Vrc,ma 2r,03 T. c leplione: _3 6E-7 -2,-jQ1l AL!gww-- Appel I, 8102 0 Hbr n3.. %Vo!ks D, -p irIu,k,fj, C qpp 14- -I:Rl,'I)VRI( K COLINTY P11:1111 TCVMRKS DFPART)IF\'l USE, ONLN D�i�c Rc-�%;ivQd R�:% ic%� Number 1 2 4 'crek, onci Dme Rrviewell A Plesaw Reltirl" w In� REQUEST FOR SITE, -, LAT -T COMMENTS Virginia Ellepartnient of Transportation Mail to: Virginia Department of Transportation Attn: Resident Engineer 14031 Old Vallee Pike Edinburg, Virginia 2282/,. Phone: (540) 984-5600 Mand deliver to: Virginia Department of Transportation Attn: Resident Engineer 2275 Northwestern Pike Winchester, Virginia 22603 Applicant: 13;e-sc (ill , Pit the inlonnation as accurateh as possible in order to assist the Virginia Department of Transportation with their r -view. Please attach five (5) copies of the site plan with traffic generation data and drainage calculations with this sheet. Applicant's Nall le: Gre.yWolfe, Inc. -Gary R Oates, LS -B, PE Telephone: 40-667-2001 —----- -- – ----- _ Mailing Address: 1073 Reabud Road Winchester, Virginia, 22603 Name of development andr or description of the request: WCS - Brooke Road Facd ty - Freezer Warehouse Additen 1 :•+cat;on u'�-Properly: ISS brc�-,i;e f oc-sd. Brooke Read Winchester, Virginia 2603 �rginia Department of Trans ort tion Cots: t� , r� Comments. AJOT fb l I t' IJ? , _ ie �. /V: -- -V DOT USE ONLY- Date RecJved _ ReNiev lumber 1 2 3 4 5 fcirc:eone; Date Rex ieN%ed Rex ision Required Date Approved VDO`i' Sig,iak;:re a Dale. ** Please Return Form to Applicant*h Subject: WCS—Brooke Road Facility -Freezer Warehouse Addition - VDOT Comments to Site Plan Date: 2/1/2018 9:58:27 AM Eastern Standard Time From: Rhonda.Funkhouser@VDOT.Virginia.gov To: greywolfeinc@aol.com Cc: jbishop@fcva.us, Lloyd.Tngram@VDOT.virginia.gov, Matthew. Smith@vdot.virginia.gov t.� M � '� '- x :.�_"'T'I i o f V I KI I BVI A DEPARTMENT OF TRANSPORTATION Staunton/Edinburg Land Development 14031 Old Valley Pike Edinburg, VA 22824 Mr. Oates, VDOT conducted a review of the Brooke Road Facility Freezer Warehouse Addition site plan with a seal date of January 2, 2018. Based on the review of the drawings, the existing entrances from Route 1322 are adequate for the proposed building expansion. Should the business ever expand in the future, existing entrances may need to be upgraded. Please ensure that all applicable agencies have the most recent set of approved drawings. We offer the following general comments: • Our review and comments are general in nature. Should details have been overlooked during plan review or conditions in the field exist such that additional measures are warranted, such measures will be completed to the satisfaction of the department. • Materials used and methods of construction shall adhere to the current observed VDOT Road and Bridge Specifications, Road and Bridge Standards, Manual on Uniform Traffic Control Devices, and Land Use Permit Special Provisions. • All drainage will be carried within the right-of-way in ditch lines or gutters along the street to a pipe or drainage easement. • Any construction related changes to the approved plan must come through the design engineer to VDOT for approval. Please allow a minimum of S business days for VDOT review. • A Land Use Permit shall be obtained before any work is performed on the State's right-of-way. The permit issued by this office and may require application fees, the salary & expenses of a State assigned inspector, and surety bond coverage. If you have any questions or need further information, please do not hesitate to contact me. Sincerely, Lloyd A. Ingram I Land Development Engineer Virginia Department of Transportation Clarke, Frederick, Shenandoah & Warren Counties 14031 Old Valley Pike Edinburg, VA 22824 voice: 540/984-5611 fax: 540/984-5607 e-mail: Lloyd.IngramCalvdot.virginia.gov