HomeMy WebLinkAbout14-04 Design PlanI SITE INFORMATION I OWNER SITE I.D.: SITE NAME: APPLICANT. SI -�E ADDRESS: COUNTY. LATITUDE: LONGITUDE: ZONING CLASSIFICATION: ZONING JURISDICTION: TAXMAP: AREA OF CONSTRUCTION: SHENANDOAH UNIVERSITY 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 1253 SHENANDOAH UNIVERSITY CINGULAR WIRELESS 7150 STANDARD DRIVE HANOVER, MD 21076 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK 39' 9' 55.9"N 78' 9' 13.8"W HE FREDERICK COUNTY 64-A-110 tF300 s.t. ENGINEER: CLOUGH HARBOUR & ASSOCIATES LLP 10800 MIDLOTHIAN TURNPIKE, SUITE 303 RICHMOND, VA 23235 CONTACT: WILLIAM L. RUCH III, P.E PHONE: (804) 897-3564 DRIVING DIRECTIONS FROM STANDARD DRIVE TAKE MD -100 W. MERGE ONTO US -29 N/COLUMBIA PIKE MERGE ONTO 1-70 W. MERGE ONTO US -340 W, EXIT 52, TOWARD CHARLESTOWN/LEESBURG MERGE ONTO US -340 & MERGE ONTO VA -7 W TOWARD WINCHESTER. MERGE ONTO 1-81 S TOWARD ROANOKE. MERGE ONTO US -17 N/MILLWOOD AVE/US-50 W. EXIT 313B TURN RIGHT ONTO UNIVERSITY DRIVE. PROJECT DESCRIPTION THIS PROJECT WILL INSTALL NEW TELECOMMUNICATIONS EQUIPMENT AT A PROPOSED TELECOMMUNICATIONS SITE. TWELVE ANTENNAS WILL BE INSTALLED ON THE TOWER. ONE 10'x20' EQUIPMENT SHELTER WILL BE ADDED TO THE SITE. ASSOCIATED POWER AND TELEPHONE CIRCUITS WILL BE ADDED WITHIN THE SITE. T cingular PROJECT NAME: SHENAN'CAH UNIVERSITY SITE ID# 12..53 PROJECT TYPE: NEW COMMUNICA.190N TOWER PROJECT LOCATION: '1460 111UNNIYERSITY DRIVE WINS ESTER, VA 22601 CiNGULAR WIRELESS CONSTRUCTION APPROVAL PPINT NA�AE SIGNATURE DATE LINGULAR WIRELESS RIFAPPROVAL PRINT Nl+Mc SIGNA ruRE DATE UNIVERSITY APPROVAL PRINT SIGNATURE DILE LOCATION MAP C9IGLtM RFPRESOiTATIVE Jo PS W B SHEET TITLE TONER ONPER CONTACT C01 ,d ?� don.corbin@cingulor.com k Z 4i Hor t St St o r wrach�kho-llp.aom ALLEGHENY TELEPHONE COMPANY � O 3 i9jm 3 0 bud.gill@cingular.com VERIZON CO1 ENLARGED SITE PLAN 2 05 / 26 / 04 P Q�bae A c h q 9 2 05 / 26 / 04 o RPh a i u s 2 05 / 26 / 04 C04 O 2 05 / 26 / 04 Bellview A e "Prc r SP✓'i 9 t 1O 2 05 / 26 / 04 S t Ginize GENERAL NOTES 2 05 / 26 / 04 RSP o = 2 05 / 26 / 04 C08 SEDIMENT & EROSION CONTROL NOTES 2 05 / 26 / 04 C09 SEDIMENT & EROSION CONTROL PLAN 2 05 / 26 / 04 C10 SHELTER LAYOUT 2 05 / 26 / 04 Feo therbe d Cane s °n o 2 05 / 26 / 04 E02 GROUNDING PLAN 2 05 / 26 / 04 E03 SITE vns5 r 1r 05 / 26 / 04 E04 LOCATION 4� 05 / 26 / 04 E05 ELECTRICAL DETAILS q nrvar Dr 05 / 26 / 04 E06 ELECTRICAL DETAILS l Ph "c F3 PtOh 'a _ /I\/l J � � � i 6 q ~a' L 05 / 26 / 04 E08 M1 4w 2 Custer Ave a � m` f 3 NO SCALE CiNGULAR WIRELESS CONSTRUCTION APPROVAL PPINT NA�AE SIGNATURE DATE LINGULAR WIRELESS RIFAPPROVAL PRINT Nl+Mc SIGNA ruRE DATE UNIVERSITY APPROVAL PRINT SIGNATURE DILE RAA 26, 201041 DRAWING PROJECT CONTACTS C9IGLtM RFPRESOiTATIVE SHEET NO: SHEET TITLE TONER ONPER CONTACT DON CORBIN CONSTRUCTION MANAGER CNA PROJECT MANAGER (410)-262-5119 don.corbin@cingulor.com ELECTRICAL COMPANY WILLIAM L. RUCH III ASSOCIATE CMGULAR CONSTRUCTION MANAGER (804) 897-3564 wrach�kho-llp.aom ALLEGHENY TELEPHONE COMPANY BUD GILL CONSTRUCTION MANAGER (410)-245-9977 bud.gill@cingular.com VERIZON RAA 26, 201041 DO NOT SCALE DRAWINGS CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & X cingularTM WIRELESS VeIOciTel L :A CLOUGH. HARBOUR &ASSOCIATES LLP ENGNEEFS. R.ANEFS 6 t ANCISGAPE PRp-viEGTS CFI .> oROJECT NO: 12760 - 1030 - 1601 N0. SUBMITTAL 1 04/23/04 85% CAD BY:MJO CHK:JDH APP'D:WER 2 05/26/04 ISSUED FOR REVIEW BY: DSS I CHK: JDH APP'D: WLR : T ' ag 162 .f IT IS A VIOLATION F LAW FOR ANY PERSON, UNLESS THEY ARE AfTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT SITE ID: CINGULAR # 1253 SITE NAME: SHENANDOAH UNIVERSITY SITE ADDRESS: 1460 UNIVERSITY DRIVE CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDIN; SHEET TITLE WITH THE WORK OR BE RESPONSIBLE FOR SAME TITLE SHEET VA MISS UTILITY OF VIRGINIA SAVE BIG, CALL BEFORE YOU DIG. SHEET NUMBER C 1-800-552-7001 T01 DRAWING INDEX SHEET NO: SHEET TITLE REVISION HISTORY NO: F DATE T01 TITLE SHEET 2 05 / 26 / 04 S01 EXISTING CONDITIONS 2 05 / 26 / 04 S02 SITE PLAN 2 05 / 26 / 04 CO1 ENLARGED SITE PLAN 2 05 / 26 / 04 CO2 TOWER ELEVATION & DETAILS 2 05 / 26 / 04 CO3 STRUCTURAL DETAILS 2 05 / 26 / 04 C04 STRUCTURAL DETAILS & NOTES 2 05 / 26 / 04 C05 STRUCTURAL NOTES 2 05 / 26 / 04 C06 GENERAL NOTES 2 05 / 26 / 04 C07 RF SCHEDULE & DETAILS 2 05 / 26 / 04 C08 SEDIMENT & EROSION CONTROL NOTES 2 05 / 26 / 04 C09 SEDIMENT & EROSION CONTROL PLAN 2 05 / 26 / 04 C10 SHELTER LAYOUT 2 05 / 26 / 04 E01 POWER & TELEPHONE PLAN 2 05 / 26 / 04 E02 GROUNDING PLAN 2 05 / 26 / 04 E03 ELECTRICAL DETAILS 2 05 / 26 / 04 E04 ELECTRICAL DETAILS 2 05 / 26 / 04 E05 ELECTRICAL DETAILS 2 05 / 26 / 04 E06 ELECTRICAL DETAILS 2 05 / 26 / 04 E07 ELECTRICAL DETAILS 2 05 / 26 / 04 E08 ELECTRICAL SPECIFICATIONS 2 05 / 26 / 04 DO NOT SCALE DRAWINGS CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & X cingularTM WIRELESS VeIOciTel L :A CLOUGH. HARBOUR &ASSOCIATES LLP ENGNEEFS. R.ANEFS 6 t ANCISGAPE PRp-viEGTS CFI .> oROJECT NO: 12760 - 1030 - 1601 N0. SUBMITTAL 1 04/23/04 85% CAD BY:MJO CHK:JDH APP'D:WER 2 05/26/04 ISSUED FOR REVIEW BY: DSS I CHK: JDH APP'D: WLR : T ' ag 162 .f IT IS A VIOLATION F LAW FOR ANY PERSON, UNLESS THEY ARE AfTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT SITE ID: CINGULAR # 1253 SITE NAME: SHENANDOAH UNIVERSITY SITE ADDRESS: 1460 UNIVERSITY DRIVE CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDIN; SHEET TITLE WITH THE WORK OR BE RESPONSIBLE FOR SAME TITLE SHEET VA MISS UTILITY OF VIRGINIA SAVE BIG, CALL BEFORE YOU DIG. SHEET NUMBER C 1-800-552-7001 T01 APPROX. TRUE PPPR�X 1 V MP . N MAPPING NOTE 1. BASEMAP INFORMATION OBTAINED FROM THE FREDERICK COUNTY DEPARTMENT OF PLANNING ON MAY 25, 2004. 2. NORTH ORIENTATION BASED ON NOTE NO. 1 3. SUBJECT TO ANY STATE OF FACTS THAT AN ACCURATE BOUNDARY SURVEY WOULD DISCLOSE. PROPERTY LINES ARE ONLY SHOWN AS APPROXIMATE. 4. SUBJECT TO ANY STATE OF FACTS THAT AN UP—TO—DATE ABSTRACT OF TITLE WOULD DISCLOSE. 5. SUBJECT TO ALL RIGHTS, EASEMENTS, COVENANTS OR RESTRICTIONS OF RECORD. 6. A BOUNDARY SURVEY WAS NOT PERFORMED BY CLOUGH, HARBOUR & ASSOCIATES LLP IN CONJUNCTION WITH THE PREPARATION OF THIS SITE. 7. NOT TO BE USED FOR LAND TRANSACTION PURPOSES. 1 EXISTING CONDITIONS NU t�UALL PARENT PARCEL OWNERS: 10 OWNER: SHENANDOAH UNIVERSITY 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 TAX MAP/PARCEL: 64 A 110 DEED BOOK—PG: 553-314 ZONING: HE AREA: 22.40 ACRES ADJACENT PARCEL OWNER: O2 OWNER: SHENANDOAH UNIVERSITY 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 TAX MAP/PARCEL: 54 A 141A DEED BOOK—PG: 656-256 ZONING -HE AREA: 7.50 ACRES OOWNER: WINCHESTER GOLF CLUB 1300 SENSENY RD WINCHESTER, VA 22602 TAX MAP/PARCEL: 54 A 141 DEED BOOK—PG: NO DATA ZONING: RA AREA: 54.55 ACRES 04 OWNER: PEMBRIDGE HEIGHTS HOMEOWNERS ASSOC. P.O. BOX 3838 WINCHESTER, VA 22604 TAX MAP/PARCEL: 64A 12 3 209A DEED BOOK—PG: 747-876 ZONING: RP AREA: 1.15 ACRES 50 OWNER: HAINES, JOHN & PAMELA 114 PRICE DRIVE WINCHESTER, VA 22602 TAX MAP/PARCEL: 64A 12 3 209 DEED BOOK—PG: 756-1448 ZONING: RP AREA: NO DATA O6 OWNER: GOCHENOUR, ROBERT & JACQUELINE 111 PRICE DRIVE WINCHESTER, VA 22602 TAX MAP/PARCEL: 64A 12 3 210 DEED BOOK—PG: 728-1466 ZONING: RP AREA: NO DATA O7 OWNER: HOVATTER, ONA CARLTON & MARGARET 105 PRICE DRIVE WINCHESTER, VA 22602 TAX MAP/PARCEL: 64A 12 3 211 DEED BOOK—PG: 755-1435 ZONING: RP AREA: NO DATA DOWNER: SHENANDOAH UNIVERSITY 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 TAX MAP/PARCEL: 64 A 109 DEED BOOK—PG: NO DATA ZONING: RP AREA: 0.62 ACRES O9 OWNER: APPLE BLOSSOM PROPERTIES, LP 370 NEFF AVE STE U HARRISONBURG, VA 22801 TAX MAP/PARCEL: 64 A 107 DEED BOOK—PG: 624-504 ZONING: B2 AREA: 1.13 ACRES 10 OWNER: MILLWOOD, LLC 1323 JAMESTOWN RD STE 101 WILLIAMSBURG, VA 23185 TAX MAP/PARCEL: 64 A 107A DEED BOOK—PG: 954-1468 ZONING: B2 AREA: 3.22 ACRES Xcingularry ��so sTANoaHo okivE. rq W�RE�LESS VelOciTel FA CLOUGH, HARBOUFI &ASSOCIATES LLP En�cnEErs. PLAnnEcs s �ANo � oxrxrE�rs 11110 MroLOTI­ TIR.111E, AIIIE 303 CHA PROJECT NO. 12760 — 1030 — 1601 NO. SUBMITTAL 104/23/04 1 859 CAD BY:MJO CHK:JDH APP'D:WLR 2 05/26/04 ISSUED FOR REVIEW BY: DSS I CH K:JDH APP'D:WLR s 16If L1 � P IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SITE ID: CINGULAR # 1253 SITE NAME: �HENANDOAH UNIVERSITY SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE EXISTING CONDITIONS SHEET NUMBER S01 APPROX. TRUE p,PPRoX 1 V MAS• N 9" T\ T EXISTING TRANSFORMER PROPOSED CINGULAR 1 1 BACKBOARD WITH 400A E07 Eot METER AND DISCONNECT (FUSED FOR 3OOA) FE01 PROPOSED CINGULAR UNDERGROUND POWER AND TELCO CONDUITS - NOTE: EXISTING STADIUM PROPOSED TELCO ROUANG EXISTING FROM UNIVERSITY DEMARC SIDEWALK �. EX/SANG LIGHT POLE TO BE REPLACED WITH A 125' TALL MONOPOLE. LIGHTS TO BE REL OCAARED ON NEW MONO— POLE AT EXISANG HEIGHT OF 60' [GO2 PROPOSED 125' MONOPOLE/L/GHT 1 2 PROPOSED 10�r2OWO'_6" HIGH CINGULAR SHELTER II�� C04 C04 ON A CONCRETE SLAB E&T---- I I Illi EXISTING 3 HIGH FENCE fGPAA;S / i i J� s -o' EXISTING ELECTRICAL EXISTING 6' EQUIPMENT SHED HIGH FENCE ,/-GRASS-/ CINGULAR TO UAL/ZE EX/SANG ACCESS AND PARK/NG AREA 1- SHELTER MUST MATCH EXISTING PRESS BOX IN ARCHITECTURAL STYLE AND FINISH. NO STONE WILL BE USED AROUND SHELTER. GRASS WILL BE REPLACED AROUND SHELTER WHERE DISTURBED. GENERAL NOTES: 1. THE PLANS SHOW SOME SUBSURFACE STRUCTURES, ABOVE—GROUND STRUCTURES AND/OR OTHER FEATURES FROM FIELD MEASUREMENTS AND RECORD MAPPING, EXACT LOCATION OF WHICH MAY VARY FROM THE LOCATIONS INDICATED. IN PARTICULAR THE CONTRACTOR IS WARNED THAT THE EXACT LOCATION OF SUCH EXISTING FEATURES IN THE AREA MAY BE DIFFERENT FROM THAT SHOWN OR MAY NOT BE SHOWN, AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROCEED WITH GREAT CARE IN EXECUTING ANY WORK. 48 HOURS BEFORE YOU DIG, DRILL, OR BLAST, CALL MISS UTILITY FOR THE MARKING OF EXISTING UTILITY LOCATIONS. 2. THE ENGINEER SHALL BE NOTIFIED IN WRITING OF ANY CONDITIONS THAT VARY FROM THOSE SHOWN ON THE PLANS. THE CONTRACTOR'S WORK SHALL NOT VARY FROM THE PLANS WITHOUT THE EXPRESSED APPROVAL OF THE ENGINEER. 3. WORK SHALL COMPLY WITH CURRENT ISSUES OF ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. ALL NECESSARY LICENSES, CERTIFICATES, ETC., REQUIRED BY AUTHORITIES HAVING JURISDICTION SHALL BE PROCURED AND PAID FOR BY THE CONTRACTOR. ....... - .......... % ---.... �-..._._ 4. CLOUGH HARBOUR & ASSOCIATES LLP (CHA) HAS NOT CONDUCTED, NOR DOES IT INTEND TO CONDUCT ANY INVESTIGATION TO DETERMINE THE PRESENCE OF ANY HAZARDOUS MATERIAL INCLUDING BUT NOT LIMITED TO ASBESTOS AND PCB'S WITHIN THE CONFINES OF THIS PROJECT. CHA WILL NOT ACCEPT ANY RESPONSIBILITY FOR THE ABATEMENT OR RESULTING CLAIMS FOR DAMAGES OR LOSSES AS A RESULT OF THE PRESENCE OF HAZARDOUS MATERIALS. IF EVIDENCE OF HAZARDOUS MATERIALS IS DISCOVERED, SUSPEND WORK AS REQUIRED BY GOVERNING STATUTES, AND NOTIFY THE CINGULAR REPRESENTATIVE. DO NOT PROCEED WITH WORK UNTIL INSTRUCTED BY THE CINGULAR REPRESENTATIVE. 5. ALL MATERIAL FURNISHED UNDER THIS CONTRACT SHALL BE NEW UNLESS NOTED OTHERWISE. ALL WORK SHALL BE GUARANTEED AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF PROPOSED UNDERGROUND 2 3 TWELVE MONTHS FOLLOWING SUBSTANTIAL COMPLETION OF PROJECT OR AS SPECIFIED. THE COAX ROUANG TO TOWER CO3 CO3 CONTRACTOR SHALL REPAIR OR REPLACE AT HIS EXPENSE ALL WORK THAT MAY DEVELOP DEFECTS IN MATERIALS OR WORKMANSHIP WITHIN THE WARRANTY PERIOD. EXISTING PRESS BOX 6. THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR ARE TO BE RESPONSIBLE FOR VERIFYING EXISTING SITE CONDITIONS AND DIMENSIONS AND THE LOCATION OF BURIED UTILITIES AT THE JOB —RESTORE ANYDIS TURBED SITE PRIOR TO THE COMMENCEMENT OF WORK. NOTIFICATION MARKING TO BE DONE BY MISS UTILITY. AREAS /N KIND TYP NO CLAIMS FOR EXTRA COMPENSATION FOR WORK RESULTING FROM CONFLICTS AND OMISSIONS WHICH COULD HAVE BEEN DISCOVERED BY FIELD VERIFICATION AND INSPECTION, WHETHER INDICATED ON THE —PROPOSED CINGULAR CPS CONTRACT DOCUMENTS OR NOT, WILL BE ENTERTAINED OR PAID. ANTENNA ATTACHED TO O SHELTER (TYP. FOR 2) CO3 7. FOLLOW MANUFACTURERS' PRINTED SPECIFICATIONS AND INSTRUCTIONS EXCEPT WHERE SPECIFIED OR INDICATED ON CONTRACT DOCUMENTS. COMPLY WITH THE MOST STRINGENT INSTRUCTIONS. f 8. THE CONTRACTOR SHALL VERIFY AND COORDINATE SIZE AND LOCATION OF ALL OPENINGS FOR �GRASSJ STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, CIVIL, OR ARCHITECTURAL WORK. -_ 9. THE CONTRACTOR SHALL VERIFY THAT THERE ARE NO CONFLICTS AMONG THE LOCATIONS OF ANY MECHANICAL, ELECTRICAL, PLUMBING, OR STRUCTURAL ELEMENTS, AND THAT ALL REQUIRED EXISTING 8' DOUBLE CLEARANCES AND CONSTRUCTION TOLERANCES FOR INSTALLATION AND MAINTENANCE ARE PROVIDED. SWING GATE NOTIFY CINGULAR REPRESENTATIVE OF ANY CONFLICTS. CINGULAR WIRELESS RESERVES THE RIGHT TO MAKE MINOR MODIFICATIONS TO THE DESIGN WITHOUT ALTERING THE CONTRACT PRICE. 10. DO NOT SCALE DRAWINGS. DIMENSIONS ARE EITHER TO THE FACE OF FINISHED ELEMENTS OR TO THE CENTER LINE OF ELEMENTS, UNLESS NOTED OTHERWISE. CRITICAL DIMENSIONS SHALL BE CONFIRMED WITH SITE MEASUREMENTS. VERIFY WITH CINGULAR REPRESENTATIVE AS APPLICABLE. EXISTING 20' ACCESS 11. THE CONTRACTOR IS RESPONSIBLE FOR DAILY CLEAN UP OF SITE AND REMOVAL AND DISPOSAL ROAD AND TURN AROUND OF ALL CONSTRUCTION DEBRIS. AT THE COMPLETION OF THE PROJECT THE CONTRACTOR SHALL THOROUGHLY CLEAN THE BUILDING SITE AND ANY ?OTHER SURROUNDING AREAS TO THE SATISFACTION OF CINGULAR WIRELESS. 12. THE CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY BRACING ANR SHALL VE PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSE, ETC., ACCORDING TO APPLICABLE CODES, STANDARDS, AND GOOD CONSTRUCTION PRACTICES. 13. ALL WORK SHALL BE DONE IN STRICT COMPLIANCE WITH ALL APPLICABLE NATIONAL, STATE, LOCAL AND OSHA CODES, STANDARDS, ORDINANCES, RULES AND REGULATIONS. 14. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR DAMAGES TO THE EXISTING FACILITY AND INSTALLATIONS RESULTING FROM CONSTRUCTION AND GENERAL NEGLIGENCE. REPAIR ALL DAMAGES AND RESTORE FACILITY AND INSTALLATIONS TO THE SATISFACTION OF CINGULAR WIRELESS AND LANDLORD AT NO EXTRA CHARGE. NOTIFY CINGULAR REPRESENTATIVE AND TOWER OWNER OF ANY SUCH DAMAGES PROMPTLY. REPAIR TO 100% SATISFACTION IMMEDIATELY. BASEMAP NOTES: 1. BASEMAP INFORMATION OBTAINED FROM A MARCH 10, 2004 SITE VISIT PERFORMED BY CLOUGH, HARBOUR & ASSOCIATES LLP, AND DOES NOT REPRESENT AN ACTUAL FIELD SURVEY. 1 SITE PLAN GRAPHIC SCALE 20 0 10 20 IN FEIM Xcinguiar2M WIRELESS 1- STANDARD ORS. HA.a "D. 21.16 VelOciTel C� CLOUGH. HARBOUR S ASSOCIATES LLP EL�NEE3S, RPN£F6 S CCTAPE /YJC)T1ECT5 oDOD PIKE. TE sD 3d3 RICHMOND. v 23235 CHA PROJECT NO: 12760 -1030 -1601 N0. SUBMITTAL 1 04/23/04 85% CAD BY: MJO I CHK: JDH APP'D: WLR 2 05/26/04 1 ISSUED FOR REVIEW BY: DSS It—.HK—,IDH APP'D: WLR �3v �� T , 029152 <P - IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SITE ID: CINGULAR # 1253 SITE NAME: HENANDOAH UNIVERSIT' SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE ENLARGED SITE PLAN SHEET NUMBER C01 PROPOSED CINGULAR RAD CENTER AT 123=0" B AGL (CONTRACTOR TO ICER/FY LOCATION OF CABLE PORTS. INSTALL NEW CABLE PORTS PER MANUFACTURERS RECOMMENDATION) PROPOSED FUTURE CARRIER RAD CENTER AT 110 -O" AGL PROPOSED FUTURE CARR/ER RAD CEN7FR AT 95=0" AGL +1 in Lr PROPOSED FUTURE DISH ANTENNA AT 80=0" AGL W SUBMITTAL 104/23/04 o PROPOSED FUTURE DISH o AN7FNNA AT 70'- 0 A 6 Z O 05/26/04 ISSUED FOR REVIEW BY: DSS CHK: JDH APP'D: WLR G9 --- — RELOCATED LIGHTS Z F- AT 60'-D" AGE V) X Ltj LL O o PROPOSED 125' ~ MONOPOLE/UGHT POLE EXISTING PRESS BOX PROPOSED CINGULAR EQUIPMENT SHEL 7ER PROPOSED UNDERGROUND COAXIAL CABLES FTI TOWER ELEVATION NO SCALE - THIS INFORMATION IS SHOWN FOR GENERAL INFORMATION PURPOSES ONLY. - BOTH THE TOWER STRUCTURE AND FOUNDATION WILL BE/HAVE BEEN DESIGNED BY OTHERS. - PRIOR TO CONSTRUCTION, THE FINAL TOWER FOUNDATION DESIGN SHOULD BE COMPARED TO THE SITE PLAN TO AVOID POTENTIAL CONFLICTS. ANTENNA FRAME BY MICROFLECT P/N 852301 (OR APPROVED EQUAL)— PROPOSED CINGULAR PANEL ANTENNAS SECTOR C 240' SECTOR A 15' EXISTING MONOPOLE SECTOR 8 120' 2-1 ANTENNA CON ICURATION PLAN - I NO SCALE NOTE: 1. CONTRACTOR TO REFER TO FINAL RF CONFIGURATION SHEET FOR ANTENNA AZIMUTHS PRIOR TO CONSTRUCTION. 2. FINAL RF CONFIGURATION SHEET TO BE SUPPLIED BY VELOCITEL. 4'x4'x5' 3000 PSI CONCRETE STOOP 1/4"/FT SLOPE (BROOM FINISH) 6x6-W2.9xW2.9 WIRE MESH - 3/4" CHAMFER ON EDGES FINISH GRADE -\ CRUSHED STONE `V TILT ASSEMBLY ANEL ANTENNA MOUNT ANTENNA IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDED PROCEDURE 3 ANTENNA W DOWN TILT NO SCALE SHELTER 1/2" NEOPRENE FILLER 4 CONCRETE STOOP NO SCALE TER FLOOR }C cingular WIRELESS 7150 STA"DARD DRIW. HAHO M 11- VelociTel L• •I CLOUGH. HARBOUR 5 ASSOCIATES LLP ENGI�EQS. RPNEFG 6 LANCY3"J+PE PIS-llEcrS iDa00 MIDLOTHIAN TURNPIKE, SUITE 303 RICHM-. v 23- CHA PROJECT NO: 12760 - 1030 - 1601 NO. SUBMITTAL 104/23/04 1 85% CAD BY: MJO I CHK: JDH APP'D: WLR 2 05/26/04 ISSUED FOR REVIEW BY: DSS CHK: JDH APP'D: WLR Y-0 1 .: � ICU H III 0.029162 a f J 5 3 Y IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SITE ID: CINGULAR # 1253 SITE NAME: SHENANDOAH UNIVERSITY SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE TOWER ELEVATION & DETAILS SHEET NUMBER CO2 J (1) -GPS ANTENNA (TYP. OF 2) FURNISHED BY CINGULAR INSTALLED BY CONTRACTOR EXISTING GRADE GRAVEL 0 i f' z w ANTENNA CABLE (SUPPLIED BY CINGULAR) ' BACKFILL i GROUNDING KIT, BUTTERFLY CLIP Q o z W/MECHANICAL CLAMP (BY CONTRACTOR) CC00° ENCASE 4" PVC CONDUIT IN CONCRETE �~/7o< 2-#5 CONTINUOUS LAP SPLICE 2'-6" ° ° J /CLR AS REQ'D. 1 N O (TOP & BOTTOM) 2'-2" w ujI J A TRENCH DETAIL 3a vv, NO SCALE 6" LAYER OF 3/4" MOUNTING BRACKET (SUPPLIED BY CRUSHED STONE CONTRACTOR) ATTACH TO SHELTER IN ACCORDANCE WITH CINGULAR CONSTRUCTION-; REPRESENTATIVE (BY CONTRACTOR). TO WAVEGUIDE ACCESS PORT PMENT SHELTER NOTE: 1. THE GPS ANTENNAS TO BE INSTALLED ON THE EQUIPMENT SHELTER WITH 4' MIN. SEPARATION FROM EACH OTHER. 2. MOUNTING BRACKETS TO BE SUPPLIED BY CONTRACTOR AND TO BE ATTACHED TO EQUIPMENT SHELTER BY CONTRACTOR. 3, MOUNTING LOCATION OF GPS ANTENNAS TO BE DETERMINED BY CINGULAR CONSTRUCTION REPRESENTATIVE. GPS ANTENNA MOUNTING DETAIL NO SCALE UNDERGROUND CONDUITS AT SHELTER NO SCALE IONOPOLE OUNDATION LONG 90' PVC ELBOW (TYP.) CONCRETE EXPANSION JOINT F-3-1 UNDERGROUND CONDUITS AT MONOPOLE - NO SCALE XcingularTM 7150 ITANDIRI III— 1A WARE D. VelOciTel �Al CLOUGH. HARBOUR & ASSOCIATES LLP E� nlEEcs. r�FnnEcs s ,oeooM�RLC,Mor"T NNIII . —TE III ID CHA PROJECT NO. 12760 — 1030 — 1601 N0, SUBMITTAL 1 04/23/04 85% CAD BY:MJO CHK:JDH APP'D:WLR 2 05/26/04 I ISSUED FOR REVIEW BY: DSS I CHK: JDH APP'D: WLR d 6 i 41. � 6 ®e 0 162 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SITE ID: CINGULAR # 1253 SITE NAME: SHENANDOAH UNIVERSITY SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE STRUCTURAL DETAILS SHEET NUMBER CO3 # 3 TIES ® 48" O.C. 0 4" (TYP) 2" CLR (TYP) I I 4" PVC CONDUIT (TYP. OF 12) UNDISTURBED SOIL ° A ° O C 1X) aC ^ OO i CC00° ENCASE 4" PVC CONDUIT IN CONCRETE + 2-#5 CONTINUOUS LAP SPLICE 2'-6" ° ° - /CLR AS REQ'D. 3 (TOP & BOTTOM) 2'-2" A TRENCH DETAIL – NO SCALE IONOPOLE OUNDATION LONG 90' PVC ELBOW (TYP.) CONCRETE EXPANSION JOINT F-3-1 UNDERGROUND CONDUITS AT MONOPOLE - NO SCALE XcingularTM 7150 ITANDIRI III— 1A WARE D. VelOciTel �Al CLOUGH. HARBOUR & ASSOCIATES LLP E� nlEEcs. r�FnnEcs s ,oeooM�RLC,Mor"T NNIII . —TE III ID CHA PROJECT NO. 12760 — 1030 — 1601 N0, SUBMITTAL 1 04/23/04 85% CAD BY:MJO CHK:JDH APP'D:WLR 2 05/26/04 I ISSUED FOR REVIEW BY: DSS I CHK: JDH APP'D: WLR d 6 i 41. � 6 ®e 0 162 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SITE ID: CINGULAR # 1253 SITE NAME: SHENANDOAH UNIVERSITY SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE STRUCTURAL DETAILS SHEET NUMBER CO3 N PREFABRICATED SHELTER EXTEND CONCRETE SLAB 8" BEYOND OUTSIDE FACE OF SHELTER ON ALL SIDES L4x4x3/8" x 1'-0" SUBMITTAL COORDINATE ANCHORING LOCATIONS WITH SHELTER MANUFACTURER I 8 1" DIAMETER x 1'-0" ANCHOR BOLT MJO CHK: JDH APP'D: WLR DRILL AND GROUT ANCHOR BOLTS TO 05/26/04 1 ISSUED FOR REVIEW CONFORM WITH A.S.T.M. A-36. NUTS AND DSS CHK: JDH APP'D: WLR WASHERS TO CONFORM TO A.S.T.M. A-563 21'-4" 1 FOUNDATION PLAN NO SCALE NOTE: INSTALL FLEXIBLE CONDUIT TO ALLOW FOR FOUNDATION MOVEMENT. #4 BAR (TYP.) ® 12" OC BOTH WAYS p � a o' p o v o o. e 5" MINIMUM GRASS—A5/�\/ //\\//� 2 SHELTER ATTACHMENT DETAIL NO SCALE 12" THICK CONC. SLAB OVER 5 MIL POLY VAPOR BARRIER 4" CRUSHED ROCK INCRETE SLAB REINFORCED x6-W2.9xW2.9 WWF TOP OF SLAB EL = +0'-6" A.F.G. (BROOM FINISH w/1" CHAMFER EDGE) #4 BAR (TYP.) ® 12" OC BOTH WAYS 3/4" CHAMFER 6x6-W2.9xW2.9 WWF io TOP/CONC. SLAB FINISH GRADE v $ o � GRASS--/K�///-, 4" CRUSHED ROCK NOTE: FOOTING SHALL BEAR ON SOILS APPROVED FOR 3000 PSF ALLOWABLE BEARING PRESSURE 3 FOUNDATION SECTION - NO SCALE XcinguiarTM WIRELE53 1150 —DARD DRi.£. 1-1— 1D. 21075 VelOcoTel �] CLOUGH, HARBOUR 6 ASSOCIATES LLP ENCNEEns. �AnnE�s s �� anociEcrs 10800PIKE. 5— 303 RICHMOND. T= 23235 CMA PROJECT NO: 12760 - 1030 - 1601 NO. 104/23/04 SUBMITTAL 1 857 CAD BY: MJO CHK: JDH APP'D: WLR 2 05/26/04 1 ISSUED FOR REVIEW BY: DSS CHK: JDH APP'D: WLR IT IS A VIOLATION OF LAW FOR ANY PERSON. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. SITE ID: CINGULAR # 1253 SITE NAME: SHENANDOAH UNIVERSITY SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE STRUCTURAL DETAILS & NOTES SHEET NUMBER u04 GENERAL NOTES 1. ALL DIMENSIONS TO, OF, AND ON EXISTING BUILDINGS, DRAINAGE STRUCTURES, AND SITE IMPROVEMENTS SHALL BE VERIFIED IN FIELD BY CONTRACTOR WITH ALL DISCREPANCIES REPORTED TO THE ENGINEER. 2. DO NOT CHANGE SIZE NOR SPACING OF STRUCTURAL ELEMENTS. 3. DETAILS SHOWN ARE TYPICAL; SIMILAR DETAILS APPLY TO SIMILAR CONDITIONS UNLESS OTHERWISE NOTED. 4. THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY_ 5. BRACE STRUCTURES UNTIL ALL STRUCTURAL ELEMENTS NEEDED FOR STABILITY ARE INSTALLED. THESE ELEMENTS ARE AS FOLLOWS: LATERAL BRACING, ANCHOR BOLTS, ETC. 6. DETERMINE EXACT LOCATION OF EXISTING UTILITIES, GROUNDS DRAINS, DRAIN PIPES, VENTS, ETC. BEFORE COMMENCING WORK. 7. INCORRECTLY FABRICATED, DAMAGED, OR OTHERWISE MISFITTING OR NONCONFORMING MATERIALS OR CONDITIONS SHALL BE REPORTED TO THE OWNER PRIOR TO REMEDIAL OR CORRECTIVE ACTION. ANY SUCH ACTION SHALL REQUIRE APPROVAL. 8. EACH CONTRACTOR SHALL COOPERATE WITH THE OWNER'S REPRESENTATIVE, AND COORDINATE HIS WORK WITH THE WORK OF OTHERS. 9. CONTRACTOR TO FOLLOW ALL STATE, LOCAL AND NATIONAL CODES AS APPLICABLE. DESIGN DATA LIVE LOADS: PER INTERNATIONAL BUILDING CODE WIND LOADS: PER INTERNATIONAL BUILDING CODE & TIA/EIA-222-F ICE LOADS: 1/2" RADIAL ON ALL COMPONENTS & CABLE SNOW LOAD: PER INTERNATIONAL BUILDING CODE SEISMIC LOADS: PER INTERNATIONAL BUILDING CODE ANTENNA SUPPORT BRACKET NOTES 1. DESIGN RESPONSIBILITY OF ANTENNA MOUNTING BRACKETS AND POLES AND ALL COMPONENTS THERE OF AND ATTACHMENT THERE TO SHALL BE THE RESPONSIBILITY OF THE MANUFACTURER. MFR. SHALL PROVIDE TO THE ENGINEER FOR APPROVAL, DRAWINGS DETAILING ALL COMPONENTS OF THE ASSEMBLY, INCLUDING CONNECTIONS, DESIGN LOADS, AND ALL OTHER PERTINENT DATA. ALL SUBMISSIONS SHALL BEAR THE STAMP AND SIGNATURE OF A PROFESSIONAL ENGINEER REGISTERED IN THE STATE THE WORK IS BEING PERFORMED_ 2- BRACKETS SHALL BE DESIGNED TO SUPPORT CURRENT AND FUTURE PANEL ANTENNAS AND COAXIAL CABLES AS SHOWN. STRUCTURAL STEEL NOTES 1. STRUCTURAL STEEL SHALL CONFORM TO THE LATEST EDITION OF THE AISC "SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS". ALL STEEL SHALL BE ASTM A-36. 2_ ALL INTERIOR STRUCTURAL STEEL USED SHALL BE, WHEN DELIVERED, FINISHED WITH ONE COAT FABRICATOR'S NON -LEAD, RED OXIDE PRIMER. PRIMING SHALL BE PERFORMED AFTER SHOP FABRICATION TO THE GREATEST EXTENT POSSIBLE. ALL DINGS, SCRAPES, MARS, AND WELDS IN THE PRIMED AREAS SHALL BE REPAIRED BY FIELD TOUCHUP PRIOR TO COMPLETION OF THE WORK. 3. ALL EXTERIOR STEEL WORK SHALL BE GALVANIZED IN ACCORDANCE WITH SPECIFICATION ASTM A123 UNLESS OTHERWISE NOTED. GALVANIZING SHALL BE PERFORMED AFTER SHOP FABRICATION TO THE GREATEST EXTENT POSSIBLE. ALL DINGS, SCRAPES, MARS, AND WELDS IN THE GALVANIZED AREAS SHALL BE REPAIRED BY FIELD TOUCHUP PRIOR TO COMPLETION OF THE WORK USING ZRC COLD GALVANIZING COMPOUND OR APPROVED EQUAL. 4. DO NOT PLACE HOLES THROUGH STRUCTURAL STEEL MEMBERS EXCEPT AS SHOWN AND DETAILED ON STRUCTURAL DRAWINGS. 5. CONNECTIONS: A. ALL WELDING SHALL BE DONE BY A CERTIFIED WELDER USING E70XX ELECTRODES AND WELDING SHALL CONFORM TO AISC AND AWS D1.1. WHERE FILLET WELD SIZES ARE NOT SHOWN, PROVIDE THE MINIMUM SIZE PER TABLE J2.4 IN THE AISC "MANUAL OF STEEL CONSTRUCTION ", 9TH EDITION. AT THE COMPLETION OF WELDING, ALL DAMAGE TO GALVANIZED COATING SHALL BE REPAIRED. B. BOLTED CONNECTIONS SHALL USE BEARING TYPE GALVANIZED ASTM A325 BOLTS (3/4" DIA) AND SHALL HAVE MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE. C. NON-STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8" DIA. GALVANIZED ASTM A 307 BOLTS UNLESS NOTED OTHERWISE. D. CONNECTION DESIGN BY FABRICATOR WILL BE SUBJECT TO REVIEW AND APPROVAL BY ENGINEER. E. ALL BOLTED CONNECTIONS SHALL HAVE A FLAT WASHER & NUT TIGHTENED TO AISC "SNUGTIGHT" CRITERIA, UNLESS NOTED OTHERWISE. STRUCTURAL STEEL NOTES (CONT.) 6. STRUCTURAL STEEL GRATING SHALL BE 1 1/2" X 3/16" GALVANIZED STEEL BAR GRATING (IKG BORDEN TYPE -WB OR EQUAL) ATTACHED ® 1'-6" o.c. WITH GRATING CLAMPS, UNLESS OTHERWISE NOTED. 7. NEW STRUCTURAL STEEL LOCATED WITHIN A BUILDING OR ENCLOSURE SHALL BE FIRERATED PER LOCAL CODE. 8. REINFORCING BARS: ASTM A625, GRADE 60 DEFORMED BARS. 9. WELDED WIRE MESH: TO ASTM A185. PROVIDE IN FLAT SHEETS ONLY. VERTICAL PLACEMENT TOLERANCE TO BE 3/8 INCH. 10_ THE CONTRACTOR SHALL FABRICATE ALL REINFORCEMENT AND FURNISH ALL ACCESSORIES, BOLSTERS, CHAIRS, SPACER BARS AND SUPPORTS NECESSARY TO SECURE THE REINFORCEMENT UNLESS INDICATED OTHERWISE. 11. IN SLABS WHERE REINFORCING IS SHOWN IN ONE DIRECTION ONLY, PROVIDE INDICATED TEMPERATURE REINFORCEMENT AT 90 DEGREES TO PRINCIPAL REINFORCEMENT. 12. LAP SPLICES: a) CONCRETE: PROVIDE CLASS B TENSION LAP SPLICES U.N.O. b) WELDED WIRE MESH: MINIMUM LAP 8 INCHES, MEASURiED BETWEEN OUTERMOST CROSS -WIRES OF EACH SHEET. CONCRETE NOTES 1. DESIGN AND CONSTRUCTION OF ALL CONCRETE ELEMENTS SHALL CONFORM TO THE LATEST EDITIONS OF THE FOLLOWING APPLICABLE CODES: ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS", ACI 318, "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE". 2. MIX DESIGN SHALL BE APPROVED BY OWNER'S REPRESENTATIVE PRIOR TO PLACING CONCRETE. PREPARE AND SUBMIT MIX DESIGNS FOR EACH TYPE AND STRENGTH OF CONCRETE IN ACCORDANCE WITH ACI 211, "PROPORTIONING CONCRETE MIXTURES, AND ACI 301, "SPECIFICATIONS FOR STRUCTURAL CONCRETE". 3. CONCRETE SHALL BE NORMAL WEIGHT, 6% AIR ENTRAINED (f1.5%) WITH A MAXIMUM 4" SLUMP, AND HAVE A MINIMUM 28 -DAY COMPRESSIVE STRENGTH OF 4000 PSI UNLESS OTHERWISE NOTED. 4. MAXIMUM AGGREGATE SIZE SHALL BE 3/4". 5. THE FOLLOWING MATERIALS SHALL BE USED: PORTLAND CEMENT: REINFORCEMENT: NORMAL WEIGHT AGGREGATE: WATER: ADMIXTURES: ASTM C 150, TYPE I ASTM A 615, GRADE 60 ASTM C 33 POTABLE NON -CHLORIDE CONTAINING 6. REINFORCING DETAILS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF ACI 315. 7. REINFORCING STEEL SHALL CONFORM TO ASTM A 615, GRADE 60, DEFORMED UNLESS NOTED OTHERWISE. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185 WELDED STEEL WIRE FABRIC UNLESS NOTED OTHERWISE. SPLICES SHALL BE CLASS "B" AND ALL HOOKS SHALL BE STANDARD, UNO. 8. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: CONCRETE CAST AGAINST EARTH ........ 3 IN. CONCRETE EXPOSED TO EARTH OR WEATHER: #6 AND LARGER....._...........................2 IN. #5 AND SMALLER & WWF ...................1 1/2 IN. CONCRETE NOT EXPOSED TO EARTH OR WEATHER OR NOT CAST AGAINST THE GROUND: SLAB AND WALL.................................3/4 IN. BEAMS AND COLUMNS ........................1 1/2 IN. 9. A CHAMFER 1" SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, UNO, IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. 10_ INSTALLATION OF CONCRETE EXPANSION/WEDGE ANCHOR SHALL BE PER MANUFACTURES WRITTEN RECOMMENDED PROCEDURE. THE ANCHOR BOLT, DOWEL OR ROD SHALL CONFORM TO MANUFACTURER'S RECOMMENDATION FOR EMBEDMENT DEPTH OR AS SHOWN ON THE DRAWINGS. NO REBAR SHALL BE CUT WITHOUT PRIOR ENGINEERING APPROVAL WHEN DRILLING HOLES IN CONCRETE. 11. CURING COMPOUNDS SHALL CONFORM TO ASTM C-309. 12. ADMIXTURES SHALL CONFORM TO THE APPROPRIATE ASTM STANDARD AS REFERENCED IN ACI -301. 13. DO NOT WELD OR TACKWELD REINFORCING STEEL. 14. ALL DOWELS, ANCHOR BOLTS, EMBEDDED STEEL, ELECTRICAL CONDUITS, PIPE SLEEVES, GROUNDS AND ALL OTHER EMBEDDED ITEMS AND FORMED DETAILS SHALL BE IN PLACE BEFORE START OF CONCRETE PLACEMENT. 15. LOCATE ADDITIONAL CONSTRUCTION JOINTS REQUIRED TO FACILITATE CONSTRUCTION AS ACCEPTABLE TO ENGINEER. PLACE REINFORCEMENT CONTINUOUSLY THROUGH JOINT. 16. REINFORCEMENT SHALL BE COLD BENT WHENEVER BENDING IS REQUIRED. 17. PLACE CONCRETE IN A UNIFORM MANNER TO PREVENT THE FORMATION OF COLD JOINTS AND OTHER PLANES OF WEAKNESS. VIBRATE THE CONCRETE TO FULLY EMBED REINFORCING. DO NOT USE VIBRATORS TO TRANSPORT CONCRETE THROUGH CHUTES OR FORMWORK. 18. DO NOT PLACE CONCRETE IN WATER, ICE, OR ON FROZEN GROUND. 19. DO NOT ALLOW CONCRETE SUBBASE TO FREEZE DURING CONCRETE CURING AND SETTING PERIOD, OR FOR A MINIMUM OF 14 DAYS AFTER PLACEMENT. 20.FOR COLD -WEATHER AND HOT -WEATHER CONCRETE PLACEMENT, CONFORM TO APPLICABLE ACI CODES AND RECOMMENDATIONS. IN EITHER CASE, MATERIALS CONTAINING CHLORIDE, CALCIUM, SALTS, ETC. SHALL NOT BE USED. PROTECT FRESH CONCRETE FROM WEATHER FOR 7 DAYS MINIMUM. 21. READY -MIX CONCRETE SUPPLIERS TO BE NRMCA-CERTIFIED. 22. NO ADDITIONAL WATER SHALL BE ADDED TO THE CONCRETE AT THE JOB SITE. 23. HOT WEATHER CONCRETE: COMPLY WITH ACI 305R. EXCAVATIONS /FOUNDATION 1. FOUNDATION EXCAVATION SHALL BE HAND -TRIMMED TO REMOVE LOOSE MATERIALS. 2. DO NOT PLACE FOOTINGS IN WATER OR ON FROZEN GROUND. 3. SOIL BEARING SURFACES, PREVIOUSLY ACCEPTED BY GEOTECHNICAL ENGINEER, WHICH ARE ALLOWED TO BECOME SATURATED, FROZEN OR DISTURBED SHALL BE REWORKED TO SATISFACTION OF GEOTECHNICAL ENGINEER. 4. DO NOT ALLOW GROUND BENEATH FOOTINGS TO FREEZE. 5. ALL STRUCTURAL BACKFILL AND SUBBASE UNDER SLABS SHALL BE SELECT STRUCTURAL FILL MEETING THE GRADATION AND SOUNDNESS REQUIREMENTS IN ACCORDANCE WITH THE FOLLOWING GRADATION: A. GRADATION. THE MATERIAL SHALL HAVE THE FOLLOWING GRADATION: SEIVE SIZE PERCENT PASSING BY WEIGHT 4 INCH 100 NO. 40 0 TO 70 NO. 200 0 TO 15 B. MATERIALS SHALL BE SUBSTANTIALLY FREE OF SHALE OR OTHER SOFT, POOR DURABILITY PARTICLES. IF TESTING IS ELECTED BY OWNER, MATERIAL WITH A MAGNESIUM SULFATE SOUNDNESS LOSS EXCEEDING 30% WILL BE REJECTED. 6_ COMPACT TO 95% STANDARD PROCTOR DENSITY PER ASTM D-698. 7. SUBGRADE BELOW SLAB -ON -GRADE SHALL BE REVIEWED AND ACCEPTED BY GEOTECHNICAL ENGINEER BEFORE CONCRETE SLAB PLACEMENT. 8. ALL LOOSE AND/OR ORGANIC MATERIAL SHALL BE REMOVED PRIOR TO PREPARATION OF THE AREA FOR PLACEMENT OF STRUCTURAL BACKFILL. OVERALL PLAN AREA OF WORK SHALL EXTEND 3'-0" MINIMUM BEYOND THE FINAL DIMENSIONS. 9_ SCARIFY THE EXISTING SOILS TO A DEPTH OF 6" AND RE -COMPACT USING A PLATE TAMPER. ANY SOFT AREAS SHALL BE OVEREXCAVATED 12" AND BACKFILLED WITH MATERIALS AND COMPACTION REQUIREMENTS SHOWN ON THE DRAWINGS. 10. PLACEMENT AND COMPACTION OF STRUCTURAL BACKFILL AND SUBBASE SHALL BE DONE IN 8" LIFTS. EXCAVATE FOR THE FOOTING EDGE AS SHOWN ON THE DRAWINGS. 11_ CONTRACTOR TO GRADE SITE LEVEL WITH EXISTING, TWO FEET BEYOND PROPOSED EQUIPMENT PAD FOOTPRINT, THEN TAPER TO EXISTING GRADE IF REQUIRED AT A MAXIMUM OF 3:1 SLOPE. DESIGN NOTES MATERIALS: STRUCTURAL STEEL A572 GRADE 50 ANGLES AND PLATES A36 RECTANGULAR STRUCTURAL TUBING A500 GRADE B (46 KSI) STANDARD PIPE A501 OR A53 GRADE B HIGH STRENGTH BOLTS A325 N OR SC CLASS A ANCHOR BOLTS A307 WELDING ELECTRODES E70XX CONCRETE (28 DAYS): SUBMITTAL 104/23/04 1 FOOTINGS 3000 PSI SLAB -ON -GRADE 4000 PSI ALL OTHER CONCRETE 3000 PSI REINFORCING STEEL A615 GRADE GO WELDED WIRE FABRIC A185 HEADED STUDS A108 xcingularTM WIRELESS 7150 STANDARD DRVE. tiA 0- MD. 21076 VelOciTel LHI 7A CLOUGH. HARBOUR & ASSOCIATES LLP EnGNEEF6. RMnE[S 6 10800 -PIKE. S01TE 303 R:CH,wOND. vA 23235 CHA PROJECT NO: 12760 - 1030 - 1601 N0. SUBMITTAL 104/23/04 1 85% CAD BY: MJO I CHK: JDH APP'D: WLR 2 0_5/26/04 1 ISSUED FOR REVIEW BY: DSS I CHK:JDH APP'D:WLR €7. ­,.,; IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGMEER, TO ALTER THIS DOCUMENT. SITE ID: CINGULAR # 1253 SITE NAME: SHENANDOAH UNIVERSITY SITE ADDRESS 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE STRUCTURAL NOTES SHEET NUMBER C05 GENERAL NOTES: 1. THE PLANS SHOW SOME SUBSURFACE STRUCTURES, ABOVE -GROUND STRUCTURES AND/OR OTHER FEATURES FROM FIELD MEASUREMENTS AND RECORD MAPPING, EXACT LOCATION OF WHICH MAY VARY FROM THE LOCATIONS INDICATED. IN PARTICULAR THE CONTRACTOR IS WARNED THAT THE EXACT LOCATION OF SUCH EXISTING FEATURES IN THE AREA MAY BE DIFFERENT FROM THAT SHOWN OR MAY NOT BE SHOWN, AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROCEED WITH GREAT CARE IN EXECUTING ANY WORK. 48 HOURS BEFORE YOU DIG, DRILL, OR BLAST, CALL MISS UTILITY FOR THE MARKING OF EXISTING UTILITY LOCATIONS. 2. THE ENGINEER SHALL BE NOTIFIED IN WRITING OF ANY CONDITIONS THAT VARY FROM THOSE SHOWN ON THE PLANS. THE CONTRACTOR'S WORK SHALL NOT VARY FROM THE PLANS WITHOUT THE EXPRESSED APPROVAL OF THE ENGINEER. 3. WORK SHALL COMPLY WITH CURRENT ISSUES OF ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. ALL NECESSARY LICENSES, CERTIFICATES, ETC., REQUIRED BY AUTHORITIES HAVING JURISDICTION SHALL BE PROCURED AND PAID FOR BY THE CONTRACTOR. 4. CLOUGH HARBOUR & ASSOCIATES LLP (CHA) HAS NOT CONDUCTED, NOR DOES IT INTEND TO CONDUCT ANY INVESTIGATION TO DETERMINE THE PRESENCE OF ANY HAZARDOUS MATERIAL INCLUDING BUT NOT LIMITED TO ASBESTOS AND PCB'S WITHIN THE CONFINES OF THIS PROJECT. CHA WILL NOT ACCEPT ANY RESPONSIBILITY FOR THE ABATEMENT OR RESULTING CLAIMS FOR DAMAGES OR LOSSES AS A RESULT OF THE PRESENCE OF HAZARDOUS MATERIALS. IF EVIDENCE OF HAZARDOUS MATERIALS IS DISCOVERED, SUSPEND WORK AS REQUIRED BY GOVERNING STATUTES, AND NOTIFY THE CINGULAR REPRESENTATIVE. DO NOT PROCEED WITH WORK UNTIL INSTRUCTED BY THE CINGULAR REPRESENTATIVE. 5. ALL MATERIAL FURNISHED UNDER THIS CONTRACT SHALL BE NEW UNLESS NOTED OTHERWISE. ALL WORK SHALL BE GUARANTEED AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF TWELVE MONTHS FOLLOWING SUBSTANTIAL COMPLETION OF PROJECT OR AS SPECIFIED. THE CONTRACTOR SHALL REPAIR OR REPLACE AT HIS EXPENSE ALL WORK THAT MAY DEVELOP DEFECTS IN MATERIALS OR WORKMANSHIP WITHIN THE WARRANTY PERIOD. 6. THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR ARE TO BE RESPONSIBLE FOR VERIFYING EXISTING SITE CONDITIONS AND DIMENSIONS AND THE LOCATION OF BURIED UTILITIES AT THE JOB SITE PRIOR TO THE COMMENCEMENT OF WORK. NOTIFICATION MARKING TO BE DONE BY MISS UTILITY. NO CLAIMS FOR EXTRA COMPENSATION FOR WORK RESULTING FROM CONFLICTS AND OMISSIONS WHICH COULD HAVE BEEN DISCOVERED BY FIELD VERIFICATION AND INSPECTION, WHETHER INDICATED ON THE CONTRACT DOCUMENTS OR NOT, WILL BE ENTERTAINED OR PAID. 7. FOLLOW MANUFACTURERS' PRINTED SPECIFICATIONS AND INSTRUCTIONS EXCEPT WHERE SPECIFIED OR INDICATED ON CONTRACT DOCUMENTS. COMPLY WITH THE MOST STRINGENT INSTRUCTIONS. & THE CONTRACTOR SHALL VERIFY AND COORDINATE SIZE AND LOCATION OF ALL OPENINGS FOR STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, CIVIL, OR ARCHITECTURAL WORK. 9. THE CONTRACTOR SHALL VERIFY THAT THERE ARE NO CONFLICTS AMONG THE LOCATIONS OF ANY MECHANICAL, ELECTRICAL, PLUMBING, OR STRUCTURAL ELEMENTS, AND THAT ALL REQUIRED CLEARANCES AND CONSTRUCTION TOLERANCES FOR INSTALLATION AND MAINTENANCE ARE PROVIDED. NOTIFY CINGULAR REPRESENTATIVE OF ANY CONFLICTS. CINGULAR REPRESENTATIVE RESERVES THE RIGHT TO MAKE MINOR MODIFICATIONS TO THE DESIGN WITHOUT ALTERING THE CONTRACT PRICE. 10. DO NOT SCALE DRAWINGS. DIMENSIONS ARE EITHER TO THE FACE OF FINISHED ELEMENTS OR TO THE CENTER LINE OF ELEMENTS, UNLESS NOTED OTHERWISE. CRITICAL DIMENSIONS SHALL BE CONFIRMED WITH SITE MEASUREMENTS. VERIFY WITH CINGULAR REPRESENTATIVE AS APPLICABLE. 11. THE CONTRACTOR IS RESPONSIBLE FOR DAILY CLEAN UP OF SITE AND REMOVAL AND DISPOSAL OF ALL CONSTRUCTION DEBRIS. AT THE COMPLETION OF THE PROJECT THE CONTRACTOR SHALL THOROUGHLY CLEAN THE BUILDING SITE AND ANY OTHER SURROUNDING AREAS TO THE SATISFACTION OF CINGULAR REPRESENTATIVE. 12. THE CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSE, ETC., ACCORDING TO APPLICABLE CODES, STANDARDS, AND GOOD CONSTRUCTION PRACTICES. 13. ALL WORK SHALL BE DONE IN STRICT COMPLIANCE WITH ALL APPLICABLE NATIONAL, STATE, LOCAL AND OSHA CODES, STANDARDS, ORDINANCES, RULES AND REGULATIONS. 14. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR DAMAGES TO THE EXISTING FACILITY AND INSTALLATIONS RESULTING FROM CONSTRUCTION AND GENERAL NEGLIGENCE. REPAIR ALL DAMAGES AND RESTORE FACILITY AND INSTALLATIONS TO THE SATISFACTION OF CINGULAR WIRELESS AND LANDLORD AT NO EXTRA CHARGE. NOTIFY CINGULAR REPRESENTATIVE AND TOWER OWNER OF ANY SUCH DAMAGES PROMPTLY. REPAIR TO 100% SATISFACTION IMMEDIATELY. 15. WHERE ONE DETAIL IS SHOWN FOR ONE CONDITION, UNLESS NOTED OTHERWISE, IT SHALL APPLY FOR ALL LIKE OR SIMILAR CONDITIONS, EVEN THOUGH NOT SPECIFICALLY MARKED ON THE DRAWINGS. 16. WHERE NEW PAVING, CONCRETE SIDEWALKS, OR PATHS MEET EXISTING CONSTRUCTION, THE CONTRACTOR SHALL MATCH THE EXISTING PITCH, GRADE, AND ELEVATION TO MAINTAIN CONTINUITY AND A SMOOTH TRANSITION. 17. CINGULAR REPRESENTATIVE IS RESPONSIBLE FOR APPLYING FOR COMMERCIAL POWER CONNECTION. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF UTILITY INSPECTIONS AND POWER COMPANY INSTALLATION. THE GENERAL CONTRACTOR IS REQUIRED TO KEEP ALL DOCUMENTATION RECEIVED FROM THE POWER COMPANY, WRITTEN AND VERBAL DISCUSSIONS WITH THE POWER COMPANY, ETC. 18. CINGULAR REPRESENTATIVE SHALL OBTAIN WRITTEN CONFIRMATION OF THE EXPECTED DATE OF COMPLETION OF THE POWER CONNECTION FROM THE POWER COMPANY. CONTRACTOR WILL PROVIDE TEMPORARY POWER FOR CONSTRUCTION. GENERAL CONTRACTOR AND HIS SUBCONTRACTORS ARE NOT ALLOWED TO CONNECT TO ANY EXISTING UTILITIES ON THE SITE. 19. DRAWINGS FORMING THIS SET ARE COMPLIMENTARY AND MUST BE READ AS ONE TOTAL DOCUMENT. DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF CINGULAR WIRELESS. THESE DRAWINGS WERE PREPARED TO BE SUBMITTED TO GOVERNMENTAL BUILDING AU IHORITIES FOR REVIEW FOR COMPLIANCE WITH APPLICABLE CODES. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO EXECUTE CONSTRUCTION INDICATED HEREIN ACCORDING TO APPLICABLE BUILDING CODES. 20. IF THE CONTRACTOR OR SUBCONTRACTOR FINDS IT NECESSARY TO DEVIATE FROM ORIGINAL APPROVED PLANS, IT IS THE CONTRACTOR'S AND THE SUBCONTRACTOR'S RESPONSIBILITY TO PROVIDE CINGULAR REPRESENTATIVE THE PROPOSED CHANGES FOR CINGULAR WIRELESS TO REVIEW AND APPROVE PRIOR TO PROCEEDING WITH SUCH CHANGES. IN ADDITION, THE CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR PROCURING ALL NECESSARY APPROVALS FROM THE BUILDING AUTHORITIES FOR THE PROPOSED CHANGES PRIOR TO PROCEEDING WITH THE REVISED WORK. THE CONTRACTOR AND SUBCONTRACTORS ARE RESPONSIBLE FOR PROCURING ALL NECESSARY INSPECTIONS AND APPROVALS FROM BUILDING AUTHORITIES DURING THE EXECUTION OF THE WORK. 21. THESE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS SHALL BE INTERPRETED TO BE A MINIMUM ACCEPTABLE STANDARD FOR CONSTRUCTION. THESE DOCUMENTS SHALL NOT (RELIEVE THE CONTRACTOR, SUBCONTRACTOR, AND/OR SUPPLIER/MANUFACTURER FROM PROVIDING A COMPLETE AND CORRECT INSTALLATION SHOULD ADDITIONAL ITEMS AND DETAILS BE REQUIRED FOR PROPER AND SAFE INSTALLATION. 22. THESE CONTRACT DOCUMENTS AND SPECIFICATIONS DO NOT CREATE A CONTRACTUAL RELATIONSHIP OF ANY KIND BETWEEN CINGULAR WIRELESS AND THE CONTRACTOR. 23. THE SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, AND LABOR DEEMED NECESSARY TO COMPLETE THE WORK/PROJECT DESCRIBED HEREIN. 24. THE CONTRACTOR SHALL OBTAIN AUTHORIZATION FROM THE CINGULAR REPRESENTATIVE TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS, 25. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER CONTRACT. 26, THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT AND MAINTAIN EXISTING CONDITIONS, EASEMENTS, PAVEMENTS, CURBING, ETC. DURING CONSTRUCTION. UPON COMPLETION OF WORK, THE CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. 27. THE CONTRACTOR SHALL MAINTAIN ALL TRAFFIC IN ALL AREAS IN ACCORDANCE WITH THE VIRGINIA DOT STANDARDS FOR TRAFFIC CONTROL. 28. THE CONTRACTOR SHALL NOTIFY THE CINGULAR REPRESENTATIVE WHERE A CONFLICT OCCURS ON ANY OF THE CONTRACT DOCUMENTS. THE CONTRACTOR IS NOT TO ORDER MATERIAL OR CONSTRUCT ANY PORTION OF THE WORK THAT IS IN CONFLICT UNTIL IS RESOLVED BY THE CINGULAR REPRESENTATIVE. 29, CONTRACTOR TO SCHEDULE AND COORDINATE WITH CINGULAR VENDOR, A 3RD PARTY INSPECTION FOR FOUNDATION, SWEEP TEST, AND ANTENNA ORIENTATION. 30. THE CONTRACTOR IS TO OBTAIN AND COMPLY WITH CONSTRUCTION REQUIREMENTS FROM THE TOWER LEASE EXHIBIT. �C cingular WIRELESS -1 STAIDARD OR— 1-0— ID. 21071 VelOciTel CH CLOUGH. HAR6OUR &ASSOCIATES LLP ENGNEEFG.FLAIV.EF6 s LAJV02'APE PRp-If.ECis �a000 N—PIKE. 5 ITE 303 RICHMOND. — 232 CHA PROJECT NO: 12760 - 1030 -1601 NO. SUBMITTAL 1 04/23/04 859 CAD BY: MJO I CHK: JDH APP'D: WLR 2 05/26/04 1 ISSUED FOR RLVIFW BY: DSS I CHK: JDH APP'D WLR t�, — �� ��— a �l.at ' 2� 2 fir? �Ayo c ITIS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SITE ID: CINGULAR # 1253 SITE NAME: HENANDOAH UNIVERSITY SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE GENERAL NOTES SHEET NUMBER C06 CABLE SCHEDULE AND RF SYSTEM DESIGN PLAN SECTOR ANTENNA POSITION MAKE MODEL RAD CTR, FT. AGL AZIMUTH COAX SIZE, IN. EST. LENGTH TAPE COLOR 1 #1 CSS DUO -1417-8686 123'± 15' 1 5/8" 150'± BROWN 1 #2 FUTURE BROWN/RED 1 #3 FUTURE BROWN/RED/BROWN 1 #4 CSS DUO -1417-8686 123'± 15' 1 5/8" 150'± RED 2 #1 CSS DUO -1417-8686 123'± 120' 1 5/8" 150'± ORANGE 2 #2 FUTURE ORANGE/YELLOW 2 #3 FUTURE ORANGE/YELLOW/ORANGE 2 #4 CSS DUO -1417-8686 123'± 120' 1 5/8" 150'± YELLOW 3 #1 CSS DUO -1417-8686 123'± 240' 1 5/8" 150'± GREEN 3 #2 FUTURE GREEN/BLUE 3 #3 FUTURE GREEN/BLUE/GREEN 3 #4 CSS DUO -1417-8686 123'± 240' 1 5/8" 150'± BLUE GPS (MOUNTED ON ICE BRIDGE POST) 1/2" 25'± GPS (MOUNTED ON ICE BRIDGE POST) 1/2" 25±. # OF ANTENNAS PER SECTOR: 4 (INSTALL 2, RESERVE 2) (2) TOWER MOUNTED AMPLIFERS PER SECTOR FUTURE LMU ANTENNA NEW EQUIPMENT YES EQUIPMENT SHELTER SIZE 10'x20' u 1 �I TRUE NORTH MAGNETIC NORTH COAX PORT ASSIGNMENTS (VIEWED FROM INSIDE EQUIPMENT ROOM/SHELTER) ANTENNA POSITION CURRENT FUTURE 1 4 3 2 1 O_ 0 U2 3 Tx Rx Rx Tx BR E BRR/��R BR/R 0 0 0\ D,Y OG O G 12' TYP 4' 4' 4' SECTOR 1 15• 1 BR FUTURE FUTURE 4 R N FUTURE SECTOR FUTURE 2 120• G� � 4 Y COLOR KEY R — RED BR — BROWN B — BLUE G GREEN Y — YELLOW 0 — ORANGE TYPICAL ANTENNA ORIENTATION AND COLOR CODING NO SCALE Xcingularry WIREiES3 VelOciTel FH: CLOUGH. HARBOUR &ASSOCIATES LLP ErG1�EI-�. PLMhE{S 6 lY�/IEL'TS —00 ry TUaHP11E. 5 iTE 303 (RICHMOND. vw 23235 D CHA PROJECT NO: 12760 — 1030 — 1601 NO. SUBMITTAL 104/23/04 FUTUROF \ SECTOR MJO CHK: JDH APP'D: WLR 3 05/26/04 1 ISSUED FOR REVIEW 240" FUTURE DSS CHK: JDH APP'D: WLR N FUTURE SECTOR FUTURE 2 120• G� � 4 Y COLOR KEY R — RED BR — BROWN B — BLUE G GREEN Y — YELLOW 0 — ORANGE TYPICAL ANTENNA ORIENTATION AND COLOR CODING NO SCALE Xcingularry WIREiES3 VelOciTel FH: CLOUGH. HARBOUR &ASSOCIATES LLP ErG1�EI-�. PLMhE{S 6 lY�/IEL'TS —00 ry TUaHP11E. 5 iTE 303 (RICHMOND. vw 23235 D CHA PROJECT NO: 12760 — 1030 — 1601 NO. SUBMITTAL 104/23/04 1 85% CAD BY: MJO CHK: JDH APP'D: WLR 2 05/26/04 1 ISSUED FOR REVIEW BY: DSS CHK: JDH APP'D: WLR `z j eI i ld 19� (,-HH II 1 2 r IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SITE ID: CINGULAR # 1253 SITE NAME: SHENANDOAH UNIVERSITY SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE RF SCHEDULE & DETAILS SHEET NUMBER C07 PROJECT NARRATIVE: 1. PROJECT DESCRIPTION: THIS PROJECT CONSISTS OF THE CONSTRUCTION OF A CONCRETE PAD, UNDERGROUND UTILITY TRENCHES, AND MISCELLANEOUS UTILITY CONNECTIONS TO THE METER BOARD AND TOWER. TOTAL DISTURBED AREA = 300 S.F. 2. EXISTING SITE CONDITIONS: THE SITE CONSISTS OF AN ACADEMIC CAMPUS AT THE UNIVERSITY. 3 ADJACENT AREAS: ADJACENT AREAS CONSIST OF DEVELOPED LAND WITHIN FREDERICK COUNTY, �C cingularTM WIRELESS -0 STANDARD D-, 1AN-R D. 21076 Vel®ciTel CLOUGH, HARBOUR & ASSOCIATES LLP Q�iGFEEIS.FINV�F_F6 6 LSYV0�3'f AE PF04�ECT5 , Da.D ..DI.—AN Tu QTc aoa RICH—D. VA 23— CHA PROJECT NO: 12760 —1030 —1601 NO. SUBMITTAL 1 04/23/04 85% CAD BY: MJO I CHK: JDH APP'D: WLR 2 105/26/04 1 ISSUED FOR REVIEW BY: DSS I CHK: JDH APP'D: WLR n ks 169 C ' r, . � ��, T An ✓Q . IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SITE ID: CINGULAR # 1253 SITE NAME: SHENANDOAH UNIVERSITY SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE SEDIMENT & EROSION CONTROL NOTES SHEET NUMBER C08 4 OFF—SITE AREAS: NO OFF—SITE AREAS ARE ANTICIPATED TO BE USED. 5. SOILS: DUE TO THE SMALL AREA OF DISTURBANCE, SOILS INFORMATION IS NOT CRITICAL IN THIS PROJECT. 6. CRITICAL AREAS: THERE ARE NO AREAS WITHIN THE PROJECT SITE THAT HAVE POTENTIAL FOR SERIOUS EROSION. 7_ EROSION AND SEDIMENT CONTROL MEASURE: A SILT FENCE WILL BE THE PRINCIPAL E&SC MEASURE ON THE SITE. OTHER MEASURES MAY BE TAKEN BY THE CONTRACTOR OR DIRECTED BY FREDERICK COUNTY IF UNFORESEEN CONDITIONS DEVELOP. A. CONSTRUCTION PRACTICES: SILT FENCE BARRIER — 3.05 SILT FENCE BARRIERS SHALL BE INSTALLED DOWN SLOPE OF AREAS WITH MINIMAL GRADES TO FILTER SEDIMENT—LADEN RUNOFF FROM SHEET FLOW AND ALSO USED AS TREE PROTECTION. INSTALLATION WILL OCCUR PRIOR TO ANY LAND DISTURBANCE. B. VEGETATIVE PRACTICES: TEMPORARY SEEDING — 3.31 � ALL DENUDED AREAS WHICH WILL BE LEFT DORMANT FOR MORE THEN 7 DAYS SHALL BE SEEDED WITH t FAST GERMINATING TEMPORARY VEGETATION IMMEDIATELY FOLLOWING GRADING. SELECTION OF SEED 0 MIXTURE SHALL DEPEND ON THE TIME OF YEAR THAT IT IS APPLIED, AND SHALL BE IN ACCORDANCE 0 WITH THE VIRGINIA EROSION AND CONTROL HANDBOOK. C. MANAGEMENT STRATEGIES: a 1. CONSTRUCTION TRAFFIC WILL BE LIMITED TO ACCESS ROADS AND AREAS TO BE GRADED. ALL TRAFFIC WILL BE PROHIBITED FROM CROSSING DRAINAGE SWALES EXCEPT WHERE ABSOLUTELY NECESSARY. 3 2. CONSTRUCTION WILL BE SEQUENCED SO THAT GRADING SEPARATIONS CAN BEGIN AND END AS Do O QUICKLY AS POSSIBLE. U 3. THE AMOUNT OF AREA DISTURBED SHALL BE MINIMIZED AT ANY ONE TIME. NEW CONSTRUCTION SHALL BE COMPLETED PRIOR TO ADDITIONAL LAND DISTURBING ACTIVITY. 0 i 4. TEMPORARY SEEDING OR OTHER STABILIZATION WILL FOLLOW IMMEDIATELY AFTER GRADING. ALL STABILIZATION SHALL BE IN ACCORDANCE WITH E&S HANDBOOK AND SHALL BE APPROVED BY THE COUNTY. v 5. AREAS NOT TO BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL EROSION AND SEDIMENT CONTROL PRACTICES. 6. THE JOB SUPERINTENDENT SHALL BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL EROSION 'I EROSION AND SEDIMENT CONTROL PRACTICES. 7. AFTER ACHIEVING ADEQUATE STABILIZATION, THE TEMPORARY E&S CONTROLS WILL BE CLEANED UP AND REMOVED. NO E&S MEASURES CAN BE REMOVED WITHOUT APPROVAL OF THE COUNTY INSPECTOR. �C cingularTM WIRELESS -0 STANDARD D-, 1AN-R D. 21076 Vel®ciTel CLOUGH, HARBOUR & ASSOCIATES LLP Q�iGFEEIS.FINV�F_F6 6 LSYV0�3'f AE PF04�ECT5 , Da.D ..DI.—AN Tu QTc aoa RICH—D. VA 23— CHA PROJECT NO: 12760 —1030 —1601 NO. SUBMITTAL 1 04/23/04 85% CAD BY: MJO I CHK: JDH APP'D: WLR 2 105/26/04 1 ISSUED FOR REVIEW BY: DSS I CHK: JDH APP'D: WLR n ks 169 C ' r, . � ��, T An ✓Q . IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SITE ID: CINGULAR # 1253 SITE NAME: SHENANDOAH UNIVERSITY SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE SEDIMENT & EROSION CONTROL NOTES SHEET NUMBER C08 APPROX. TRUE AppROX MAG N 9" EXISTING 3' HIGH FENCE PROPOSED 125' MONOPOLE/LGHT PROPOSED 10'r2OWO =6" HIGH CINGULAR SHELTER ON A CONCRETE SLAB EXISTING SIDEWALK s�I C I I I I IIII GRASS-/ I I J)) L_J I EXISTING ELECTRICAL EXISTING 6' EQUIPMENT SHED HIGH FENCE PROPOSED UNDERGROUND COAX ROU77NG TO TOWER EXISTING PRESSBOX -RESTORE ANY 9157ZIRBED AREAS IN KIND�(TYP.) -51LT FENCEF NDE 1 /-GRASS- EXISTING 8 DOUBLE SWING GATE 1 SEDIMENT & EROSION CONTROL PLAN GRAPHIC SCALE 20 0 10 2C I I I I IN FEET J BASEMAP NOTES: 1, BASEMAP INFORMATION OBTAINED FROM A 03/10/04 SITE VISIT PERFORMED BY CLOUGH, HARBOUR & ASSOCIATES LLP, AND DOES NOT REPRESENT AN ACTUAL SURVEY. SEQUENCE OF CONSTRUCTION: CONSTRUCTION OF A SILT FENCE (WITHOUT WIRE SUPPORT) 1. SET THE STAKES. I � IJ MAX.'l l 1 I� /_ ISI -Ii FLOW -1 x,111 - 3. STAPLE FILTER MATERIAL TO STAKES AND EXTEND IT INTO THE TRENCH. 2. EXCAVATE A 4" X 4" TRENCH UPSLOPE ALONG THE LINE OF STAKES. 4. BACKFILL AND COMPACT THE EXCAVATED SOIL. SHEET FLOW IN! / 1 POINTS A SHOULD BE HIGHER THAN POINT B. DRAINAGEWAY INSTALLATION ( FRONT ELEVATION ) F-2-1 EROSION CONTROL DETAIL NO SCALE THE FOLLOWING IS THE GENERAL SEQUENCE OF THE CONSTRUCTION TO BE FOLLOWED IN ORDER TO PUT THE PROPOSED SEDIMENT EROSION CONTROL MEASURES IN PLACE_ 1. THE OWNER SHALL GIVE THE COUNTY INSPECTOR 24 HOURS NOTIFICATION TO SCHEDULE AN ON-SITE PRE -CONSTRUCTION MEETING FOR THE ISSUANCE OF A LAND DISTURBANCE PERMIT. 2. STAKE LIMITS OF DISTURBANCE. 3. CONSTRUCT SILT FENCE WHERE INDICATED ON THE PLANS. 4. LIMIT DISTURBANCE TO MINIMUM NECESSARY TO PERFORM CONSTRUCTION AND PROVIDE STABILIZATION FOR DENUDED AREAS AS REQUIRED OR DIRECTED BY THE COUNTY. 5. CONSTRUCT ALL OTHER UNDERGROUND UTILITIES IN ACCORDANCE WITH CONSTRUCTION PLANS. 6. STABILIZE ALL DISTURBED AREAS WITH PERMANENT OR TEMPORARY SEEDING. 7. UPON COMPLETION OF ROUGH GRADING, PROCEED WITH CONSTRUCTION. 8. AFTER CONSTRUCTION AREAS ARE STABILIZED, FINISH GRADE AND SPREAD GRAVEL IN THE SITE AREA. SILT FENCE IS NOT TO BE REMOVED WITHOUT PERMISSION FROM THE COUNTY INSPECTOR. 9. MAINTAIN ALL SEDIMENT EROSION CONTROL MEASURES AS IDENTIFIED. X cingular WIRELESS 7150 -DARD DRIVE. HAN-R MD, 21076 Vel®ciTel CLOUGH. HARBOUR & ASSOCIATES LLP ENG(.EEFG,FLNV\EFS 6 D6DD M DLO H AN' R PIKE. I 303 CHA PROJECT NO: 12760 - 1030 - 1601 N0. SUBMITTAL 104/23/04185% 1 CAD BY: MJO I CHK: JDH APP'D: WLR 2 05/26/04 1 ISSUED FOR REVIEW BY: DSS I CHK: JDH APP'D- WLR . ► ' a 2 ' A,; 4 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SITE ID: CINGULAR # 1253 SITE NAME: HENANDOAH UNIVERSIT' SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE SEDIMENT & EROSION CONTROL PLAN SHEET NUMBER C09 I 1 10 11 I 12 O DESIGN IS BASED UPON SITE OBSERVATIONS ONLY. GENERAL NOTES: 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS AND ALL APPLICABLE LOCAL CODES. 2. CONDUIT ROUTINGS ARE SCHEMATIC. SUBCONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED. 3. SERVICE SHALL BE 120/240 VAC, 300 AMP, 1 -PHASE - 4. CONTRACTOR TO BE AWARE OF AND AVOID OTHER UNDERGROUND UTILITY RUNS WITHIN THE SITE COMPOUND. 5. CONDUIT RUNS SHALL HAVE ONE PULLBOX AFTER EACH 360' OF BEND. 3 ------------------ E07 6 E04 1 TYP. E03 1 POWER & TELEPHONE PLAN 0 2' 6' 16' I I I I I ( IN FEET ) LEGEND fa UTILITY POLE � SERVICE PANEL/DISCONNECT ® GENERATOR RECEPTACLE O 8 METER SOCKET BY OTHERS METER BY UTILITY COMPANY EXPOSED CONDUIT - - - - - UNDERGROUND ELECTRICAL/TELEPHONE ® CODED DRAWING NOTE DETAIL NUMBER XX -- DRAWING(S) NUMBER ABBREVIATIONS AWG AMERICAN WIRE GAUGE DWG DRAWING RGS RIGID GALVANIZED STEEL TYP. TYPICAL W/ WITH CODED DRAWING NOTES: EXISTING PAD MOUNTED UTILITY TRANSFORMER. PROVIDE NEMA 2 HOLE OLUG WITH CRIMP CONNECTORS ON L.V. TERMINALS. ALL HARDWARE TO BE STAINLESS STEEL. COORDINATE ALL THE WORK WITH UTILITY CO. REPRESENTATIVE. OPROVIDE 400A, 120/24OV, 10, NEMA 3R METER BASE ACCEPTABLE TO LOCAL POWER COMPANY. METER BY POWER COMPANY_ O 4"C. w/(3) 350 KCM + #4G. OSERVICE PANEL/DISCONNECT BY SHELTER MANUFACTURER. LINE SIDE TERMINATIONS BY THIS CONTRACT. OTO EXISTING TELCO DEMARC. EXACT LOCATION TO BE DETERMINED IN FIELD. 0 6 2"C. w/(2) 4/24 CAT 5 CABLES AND PULL ROPE. TO BE PROVIDED AND PULLED IN BY CONTRACTOR. O INTERIOR TELEPHONE BOARD BY SHELTER MANUFACTURER. OPROPOSED MONOPOLE. 0 9 PROVIDE 40OA/2P NEMA 3R FUSIBLE DISCONNECT w/LOCKABLE HANDLE AND w/(2) 300A FUSES. 10 4"C. w/(3) 350 KCM. 11 PROVIDE NEW BACKBOARD. 12 PROVIDE NEMA 3R ENCLOSURE PER UTILITY SPECIFICATIONS. X cingular WIRELESS VelOcITel CLOUGH, HARBOUR &ASSOCIATES LLP -00 11-11TAl TIRIFIIE. SUITE III CHA PROJECT NO: 12760 -1030 -1601 N0, SUBMITTAL 1 04/23/04 859 CAD BY: CMM I CHK: MJO APP'D: WLR 2 05/26/04 JiSSUED FOR REVIEW BY: CMM CHK: MJO APP'D WLR ,� v3 El IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SITE ID: CINGULAR # 1253 SITE NAME: SHENANDOAH UNIVERSIT' SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE POWER & TELEPHONE PLAN SHEET NUMBER E01 r— — — —— — — — — — --� ! I I � I 3 2 I 1 E04 ; E05 ; TYP_ ' I 1 I ' I ' 1 8 -- 2 3 I I E03 ! CINGULAR ! PRE—FAB SHELTER ; 0 I 2 I 1 I I I I 4 E04 ! TYP. ' 5 E06 TYP. ENLARGED EQUIPMENT - 0 2' e' 16' i I ( IN FEET ) 117 MA 2 3 E03 1E0"I -- 0 --- TYP. I _ _ 1 I ■�El F-2-1 METER GROUNDING p 2' 4' 8' ( IN FEET ) ABBREVIATIONS AWG AMERICAN WIRE GAUGE BCW BARE COPPER WIRE CGBE COAX GROUND BAR EXTERNAL CIGBE COAX ISOLATED GROUND BAR EXTERNAL DWG DRAWING MIGB MASTER ISOLATION GROUND BAR TYP. TYPICAL W/ WITH CODED DRAWING NOTES: O#2 SOLID TINNED BCW. TERMINATE AT METER PER UTILITY COMPANY SPECIFICATIONS, PER NEC REQUIREMENTS AND AS INDICATED. OIGR BY SHELTER MANUFACTURER. GROUNDING CONNECTIONS INSIDE SHELTER BY OTHERS UNLESS NOTED OTHERWISE. O#2 SOLID TINNED BCW BURIED EXTERIOR GROUND RING. PLACE 2' OFF FOUNDATION AND AT 30" MINIMUM DEPTH. OPROPOSED MONOPOLE. 50 MIGB. O CGBE. 70 UNDERGROUND COAX ROUTING. OINTERIOR MAIN GROUND BAR BY SHELTER MANUFACTURER. CABLES AND TERMINATIONS BY THIS CONTRACT. OCONNECTION FROM EXTERIOR GROUND RING TO INTERIOR HALO. X cingular WIRELESS Vei®ciTel L_ 'I CLOUGH. HARBOUR 6 ASSOCIATES LLP EnGrvF6G.Fi_Mf�EF6 6 LNVO2�,F'E AP04iEGT5 aaoo P 2- SUITE 303 R u —.. YA CHA PROJECT NO - 12760 — 1030 — 1601 N0. SUBMITTAL 1 04/23/04 85% CAD BY: CMM CHK: MJO APP'D: WLR 2 05/26/04 JISSUED FOR REVIEW BY: CMM I CHK: MJO APP'D: WLR -14 ji gg pp 1�� 916 Y'rY S 0 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT SITE ID: CINGULAR # 1253 SITE NAME: SHENANDOAH UNIVERSITY SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE GROUNDING PLAN SHEET NUMBER E02 LEGEND GROUNDING SYSTEM NOTES: 1. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND 7. ALL EXTERIOR GROUND CONDUCTORS SHALL BE #2 AWG SOLID TINNED COPPER UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN UNLESS OTHERWISE INDICATED. ---- GROUNDING WIRE, #2 BCW U.N.O. THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT. 8. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED. BACK 0 COMPRESSION TYPE CONNECTION 2. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC (CADWELD) TO BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS ARE PERMITTED. CONNECTIONS. 9, USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED ® GROUND ROD 3. ALL GROUND CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC (CADWELD). WHEN 45' BENDS CAN BE ADEQUATELY SUPPORTED. ® 5/8" x 10'-0" COPPER CLAD 4. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR & EXTERIOR) SHALL BE FORMED 10. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED 5 GROUND ROD W/ ACCESS USING HIGH PRESS CRIMPS. OHMS. TESTING SHALL BE PERFORMED IN ACCORDANCE WITH PROJECT SPECIFICATIONS FOR FACILITY GROUNDING, USING FALL POTENTIAL METHOD. 5. ALL EXOTHERMIC CONNECTIONS TO THE GROUND RODS SHALL START AT THE TOP & CINGULAR REPRESENTATIVE TO BE PRESENT BEFORE AND AFTER TYING INTO GROUND ■ CADWELD CONNECTION HAVE A VERTICAL SEPARATION OF 6" FOR EVERY ADDITIONAL CONNECTION. RING. MG 6. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION 11. ALL EXOTHERMIC CONNECTIONS, BELOW GRADE SHALL MADE AT A GROUND ROD. ADD Ti MIGB MIGB — GROUND BAR RESISTANT MATERIAL. ADDITIONAL GROUND RODS AS REQUIRED. NO FLOATING CONNECTIONS ARE PERMITTED. MULTIPLE CONNECTIONS TO A GROUND ROD ARE PERMITTED IF THE CG��, PROPER MOLDS ARE USED. c1c� CIGBE — GROUND BAR O METER SOCKET BY OTHERS METER BY UTILITY COMPANY ® CODED DRAWING NOTE DETAIL NUMBER DRAWING(S) NUMBER r— — — —— — — — — — --� ! I I � I 3 2 I 1 E04 ; E05 ; TYP_ ' I 1 I ' I ' 1 8 -- 2 3 I I E03 ! CINGULAR ! PRE—FAB SHELTER ; 0 I 2 I 1 I I I I 4 E04 ! TYP. ' 5 E06 TYP. ENLARGED EQUIPMENT - 0 2' e' 16' i I ( IN FEET ) 117 MA 2 3 E03 1E0"I -- 0 --- TYP. I _ _ 1 I ■�El F-2-1 METER GROUNDING p 2' 4' 8' ( IN FEET ) ABBREVIATIONS AWG AMERICAN WIRE GAUGE BCW BARE COPPER WIRE CGBE COAX GROUND BAR EXTERNAL CIGBE COAX ISOLATED GROUND BAR EXTERNAL DWG DRAWING MIGB MASTER ISOLATION GROUND BAR TYP. TYPICAL W/ WITH CODED DRAWING NOTES: O#2 SOLID TINNED BCW. TERMINATE AT METER PER UTILITY COMPANY SPECIFICATIONS, PER NEC REQUIREMENTS AND AS INDICATED. OIGR BY SHELTER MANUFACTURER. GROUNDING CONNECTIONS INSIDE SHELTER BY OTHERS UNLESS NOTED OTHERWISE. O#2 SOLID TINNED BCW BURIED EXTERIOR GROUND RING. PLACE 2' OFF FOUNDATION AND AT 30" MINIMUM DEPTH. OPROPOSED MONOPOLE. 50 MIGB. O CGBE. 70 UNDERGROUND COAX ROUTING. OINTERIOR MAIN GROUND BAR BY SHELTER MANUFACTURER. CABLES AND TERMINATIONS BY THIS CONTRACT. OCONNECTION FROM EXTERIOR GROUND RING TO INTERIOR HALO. X cingular WIRELESS Vei®ciTel L_ 'I CLOUGH. HARBOUR 6 ASSOCIATES LLP EnGrvF6G.Fi_Mf�EF6 6 LNVO2�,F'E AP04iEGT5 aaoo P 2- SUITE 303 R u —.. YA CHA PROJECT NO - 12760 — 1030 — 1601 N0. SUBMITTAL 1 04/23/04 85% CAD BY: CMM CHK: MJO APP'D: WLR 2 05/26/04 JISSUED FOR REVIEW BY: CMM I CHK: MJO APP'D: WLR -14 ji gg pp 1�� 916 Y'rY S 0 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT SITE ID: CINGULAR # 1253 SITE NAME: SHENANDOAH UNIVERSITY SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE GROUNDING PLAN SHEET NUMBER E02 INSIDE SHELTER O 300A J 4 2P NOTES 1. ELECTRICAL SERVICE SHALL BE RATED 300A, 240/12OV, 10 3W 2. FOR CODED NOTES SEE DWG. E01 F -,-I POWER & TELEPHONE DIAGRAM - I NO SCALE SECTOR 1 SECTOR 2 ANTENNA (TYP. OF 4) ANTENNA (TYP. OF 4) NOTE 1 NOTE 1 ANTENNA ANTENNA c OAX ANTENNA ANTENNA CO, PIPE GND KIT PIPE G'ARI FIT SECTOR 3 ANTENNA (TYP. OF 4) NOTE 1 ANTENNA ANTENNA COAX PIPE �N P FIT ECD DA TMA LL TI a Q a Q Q Q a ED ED a Q Q Q GND BAR GND BAR GND BAR CDED alm Qlm alDo TOP OF 2 0 2) #2 BCWMONOPOLE EDm MONOPOLE CGBE INSULATED CGBE RING GREEN BOTTOM OF 3 U MONOPOLE - 00 N v MONOPOLE ANTENNA COAX GND KIT CABLE AC UNITS LMETER PER NEC EXISTING GPS FENCE CONNECTIONS (TYP.) INSIDE SHELTER m v BY CINGULAR m N � DID CONDUITS NOTES 1. BOND ANTENNA GROUNDING KIT CABLE TO GROUND BAR. 2. #2 (SOLID TINNED) BCW BURIED GROUND RING. 3. FOR GROUNDING CONNECTION & DETAILS, SEE LAYOUT DRAWINGS. 4. INSTALL GROUND RODS AT LOCATIONS AS SHOWN ON GROUNDING PLAN. 5. INTERIOR GROUND RING FOR EQUIPMENT BY SHELTER MANUFACTURER. SCHEMATIC DIAGRAM - GROUNDING SYSTI NO SCALE SERVICE DISCONNE T�_:_�'i (2) #2 BCW I BACKBOARD FRAME NOTES 2 & 3 DID GROUND ROD(S) �l — TELCO ENCLOSURE Xcingular WIRELESS Vel®ciTel LF HAl CLOUGH. HARBOUR &ASSOCIATES LLP EN nIEEFS. RAME0.5 6 1OBOa oscAVE �+co+rrEci E Sas CHA PROJECT NO: 12760 — 1030 — 1601 NO. SUBMITTAL 1 04/23/04 85% CAD _ BY: CMM CHK: MJO APP'D: WLR 2 05/26/04 JISSUED FOR REVIEW BY: CMM I CHK: MJO APP'D: WLR Al -�y NOTES 2 & 3 �j ,, GROUND ROD(S) r _ o 162 s Ell fAt IT ISA VIOLATION SOF LAWFOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SITE 10: CINGULAR # 1253 SITE NAME: SHENANDOAH UNIVERSITY SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE ELECTRICAL DETAILS SHEET NUMBER E03 CONNECTIONS INSIDE SHELTER BY CINGULAR UNLESS MGB OTHERWISE TELCO INDICATED. BOARD NOTE 5 SHELTER FRAME 3 m � m 3 m DID CONDUITS NOTES 1. BOND ANTENNA GROUNDING KIT CABLE TO GROUND BAR. 2. #2 (SOLID TINNED) BCW BURIED GROUND RING. 3. FOR GROUNDING CONNECTION & DETAILS, SEE LAYOUT DRAWINGS. 4. INSTALL GROUND RODS AT LOCATIONS AS SHOWN ON GROUNDING PLAN. 5. INTERIOR GROUND RING FOR EQUIPMENT BY SHELTER MANUFACTURER. SCHEMATIC DIAGRAM - GROUNDING SYSTI NO SCALE SERVICE DISCONNE T�_:_�'i (2) #2 BCW I BACKBOARD FRAME NOTES 2 & 3 DID GROUND ROD(S) �l — TELCO ENCLOSURE Xcingular WIRELESS Vel®ciTel LF HAl CLOUGH. HARBOUR &ASSOCIATES LLP EN nIEEFS. RAME0.5 6 1OBOa oscAVE �+co+rrEci E Sas CHA PROJECT NO: 12760 — 1030 — 1601 NO. SUBMITTAL 1 04/23/04 85% CAD _ BY: CMM CHK: MJO APP'D: WLR 2 05/26/04 JISSUED FOR REVIEW BY: CMM I CHK: MJO APP'D: WLR Al -�y NOTES 2 & 3 �j ,, GROUND ROD(S) r _ o 162 s Ell fAt IT ISA VIOLATION SOF LAWFOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SITE 10: CINGULAR # 1253 SITE NAME: SHENANDOAH UNIVERSITY SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE ELECTRICAL DETAILS SHEET NUMBER E03 TACK COAT6 IN ASPHALT MIN PAVEMENT SAWCUT --4\ SLOPE TO SUIT SOIL CONDITION BACKFILL PER EARTH- WORK SPECIFICATIONS 6,. — FINISHED GRADE OR MIN / EXISTING ASPHALT / OR CONCRETE PAVEMENT TYPICAL PIPES / OR CONDUITS 6 MIN BEDDING PER EARTH- WORK SPECIFICATIONS TRENCH AS SHOWN ON PLANS 2" (MIN) ASPHALT PAVEMENT REQUIREMENT 5'-0" (MAX) VERTICAL DEPTH W/O SHORING * FINISHED GRADE OR NEW HOT MIX ASPHALT SURFACE COAT OR CONCRETE PAVEMENT TO MATCH EXISTING CONDITIONS WHERE APPLICABLE 1 TRENCH DETAIL NO SCALE REMOVEABLE COVER. COVER SHALL BE REMOVABLE BY HAND. NO TOOLS SHALL BE REQUIRED FOR REMOVAL. — GRADE GRADE 2'-0" LONG X 6" DIA. Z CADWELD SCHEDULE 40 WHITE PVC RING GROUND CABLE TO ROD CADWELDED - #2 AWG BCW GROUND RING #2 AWG BCW GROUND ROD COPPERWELD 1" WIDE SLOT FOR - 5/8"0x10'-0" LONG GROUND WIRE. EXTEND 2" ABOVE GROUND WIRE. CRUSHED ROCK INSIDE, BELOW AND AROUND SLEEVE. EXOTHERMIC WELD SHALL 3 GROUND ROD REMAIN VISIBLE. NO SCALE FINISHED GRADE, AC OR CONC PAVING MATCH SLOPE AND THICKNESS OF EXISTING a I • • 4 I GROUND ROD WITH ACCESS NO SCALE (2" PVC SCH. 40) TELEPHONE CONDUIT WHERE APPLICABLE ' SIZE PER LOCAL TEL. CO. (1) ACTIVE CONDUIT W/ PULL ROPE & CABLE UNDERGROUND UTILITY WARNING TAPE AZUNDISTURBED _ COMPACTED BACKFILL --III PER EARTHWORK SPECIFICATION FOR TRENCHING SEE DETAIL I lid SAND OR NATIVE SOIL FILL PER UTILITY COMPANY SPECIFICATIONS L— ELECTRICAL CONDUIT WHERE APPLICABLE 4" PVC SCH. 40 6" (MIN) _ W/ PULL ROPE & CABLE * SEPARATION DIMENSION TO BE VERIFIED WITH LOCAL UTILITY COMPANY REQUIREMENTS 2 DUCT BANK ELECTRIC TELEPHONE NO SCALE EXISTING ANTENNA TO ANTENNA MONOPOLE GROUND BAR (CIGBE) TOP OF MONOPOLE SEE NOTE 1. SEE DETAIL (SIMILAR) E06 - -LUG STANDARD / GROUND KIT (TYP.) #2/0 GREEN ISULATED #6 AWG (PROVIDED Ll � WITH GROUND KIT TYP.) 1, 1+ fl T ANTENNA GROUND BAR (CIGBE) BOTTOM OF MONOPOLE SEE NOTE I. SEE DETAIL B COAX CABLE - E06 NOTE: TYP. FOR ALL ( ) LUG 1. NUMBER OF GROUND BARS MAY VARY I DEPENDING ON THE TYPE OF TOWER, LUG ANTENNA LOCATION AND CONNECTION TO ACCA !� (2) #2 AWG BCW 2, AARSEPARATE GROUND BAR N. PROVIDE AS REQUIRED. O BEUSED VIA TRAY OR ICEBRIDGE FOR GPS ANTENNA_ MONOPOLE PIER #2 AWG BCW RING GROUND #2 AWG BCW I 5 ANTENNA CABLE GROUNDING TO GROUND BAR AND MONOPOLE X cingular- WIRELESS 1151 STAIIARI Dl- 1-1— ­ 21111 VelOciTel FH �I CLOUGH. HARBOUR &ASSOCIATES LLP ��. RANI•EFS E oaoo R M.IN. VA z3 3 s TE 3a3 CHA PROJECT NO' 12760 - 1030 - 1601 N0. SUBMITTAL 1104/23/04 85% CAD BY CMM CHK:MJO APP'D:WLR 2 05/26/04 JISSUED FOR REVIEW BY: CMM I CHK: MJO APP'D: WLR 4 1 � , yl`} � � fy f �r ��i • IT IS AVIOCATION Cf��L�VWTOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SITE ID: LINGULAR # 1253 SITE NAME: SHENANDOAH UNIVERSITY SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE ELECTRICAL DETAILS SHEET NUMBER E04 0 0 0 0 PREFAB SHELTER WALL JUMPERS TO EQUIPMENT BY OTHERS 3 POLYPHASER SURGE PROTECTION (TYP.) SUPPLIED BY CONTRACTOR SURGE SUPPRESOR RACK SUPPLIED BY CONTRACTOR 1 GROUND BAR BY SHELTER E06 MANUFACTURER #2 AWG BCW TO EXTERIOR GROUND RING INDOOR I OUTDOOR A ICE BRIDGE ANTENNA CABLES ( TYP. ) _ (TYP-) � — ANDREWS GROUNDING WAVEGUIDE KIT (TYP) WALL/ROOF FEED THRU ASSEMBLY BY SHELTER. MANUFACTURER. GROUND BAR BY SHELTERRED MANUFACTURER #2 AWG BCW TO R EXTERIOR GROUND RING 1 CABLES INSTALLATION WITH WALL ROOF FEED THRU ASSEMBLY NO SCALE MICROFLECT 12—PORT ENTRY PORT SURGE SUPPRESSOR RACK INSIDE VIEW EXTERIOR ENTRY PORT GROUND BAR (BY SHELTER MFR) 1 E06 NM FLEXIBLE CONDUIT EXTENDS INTO EXISTING OPENING; CAULK AROUND FLEX FINAL GRADE 2-----T--- ---i CADWELD TO GROUND RING OF SHELTER ROOM DY CRIMP, TYP INTERIOR GROUND HALO #2 AWG GREEN STRANDED #2 AWG GREEN STRANDED #2 AWG GREEN STRANDED TO SURGE SUPPRESSOR GROUND BAR GROUND COAX PORT o — o MASTER GROUND BAR (MGB)v0000vooa #2 AWG TINNED SOLID EXOTHERMIC WELD CONDUCTOR TO EXTERIOR (CAD—WELD) GROUND RING 3 SURGE SUPPRESSOR GROUNDING DETAIL NO SCALE Vii: ►AN INTERIOR MASTER GROUND BAR (BY SHELTER MFR) EXISTING OPENING; MATCH CAULK TO SHELTER INTERIOR WALL TER INTERIOR WALL 2 I SHELTER WALL PENETRATION DETAIL NO SCALE X cingular WIRELESS Vel®ciTel CLOUGH. HARBOUR &ASSOCIATES LLP EhY�NEEfS. RIYJ�EF6 6 lFwpSCaPE P!L]fiECTS 10800 PIKE. S ITE 303 CTIA PROJECT NO: 12760 — 1030 — 1601 NO. SUBMIF1Al 1 04/23/04 1 85% CAD BY: CMM CHK:MJO APP'D:WLR 2 105/26/04 ISSUED FOR REVIEW BY: CMM I CHK: MJO APP'D: WLR Ja. 4. ¢� 5 rINLEIS A VIOLAT ION`bo i_.�w POR."AdV PERSON. SS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. SITE ID: CINGULAR # 1253 SITE NAME: SHENANDOAH UNIVERSITY SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE ELECTRICAL DETAILS SHEET NUMBER E05 GROUND BAR ON WALL OR ON ANTENNA TOWER B Fo TWO HOLE LUG, W/#2 AWG BCW OR RING GROUND 1 GROUND WIRE INSTALLATION TO GROUND BAR NO SCALE ACCA ENCLOSURE 1 1/4" 0 MAX. ANTENNA CABLE — I I CABLEWAVE WEATHERPROOFING KIT ' 12" APPROX. 33/4 6" #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR) (STANDARD GROUNDING KIT) LEGEND 5 3" 7/16.. /4 0 0 2" 0 0 ° 0 ° 0 0 ° 0 ° o ® 00 0%0 0 of ° o ° 0 0 1 1" 1 1 — COPPER GROUND BAR. HOLE CENTERS TO MATCH NEMA DOUBLE LUG CONFIGURATION. 2 — INSULATORS, NEWTON INSTRUMENT CAT. N0. 3061-4. (NOT TO BE USED ON BARS PHYSICALLY ATTACHED TO TOWER.) 3 — 5/8" LOCKWASHERS, NEWTON INSTRUMENT CO. CAT. N0. 3015-8 4 — WALL MOUNTING BRACKET, NEWTON INSTRUMENT CO. CAT NO. A-6056 5 — 5/8-11 X 1" H.H.C.S.BOLTS, NEWTON INSTRUMENT CO. CAT NO. 3012-1 GROUND BAR TYPE REQUIRED LENGTH MIGB & TOWER 20" SECTOR 12" 2 GROUND BAR NO SCALE ACCA ENCLOSURE 2 1/2" 0 MAX. ANTENNA CABLE � I CABLEWAVE WEATHERPROOFING KIT GROUND KIT TO ANTENNA GPS CABLE #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR) (STANDARD GROUNDING KIT) 12" APPROX. CABLE GROUND KIT TO ANTENNA CABLE NOTE: DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 4 CABLE GROUND KIT CONNECTION NO SCALE CONNECTOR WEATHERPRI KIT (TYP.) FROM PNSENNP RX NOTE: DO NOT INSTALL CABLE GROUND TX KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO CIGBE tWEATHERPROOFING KIT, (TYP.) r r I I I I I STANDARD GROUNDING[4 L L (SEE(TNOTE) \� r — ANTENNA CABLE TO CABLE TRAY (TYP.) 1 I #6 AWG '— CIGBE GROUND BAR NEWTON SIMILAR TO MOUNTED NEAR/BELOW FROM ANTENNA ANTENNA FRAME SUPPORT �_. �"'----..— #2/0 GREEN #2 AWG BCW INSULATED TO ATTACH TO EACH ANTENNA--- —'—'— LOWER CIGBE SUPPORT BRACKET F-31 CONNECTION OF GROUND WIRES TO GROUNDING BAR @ ANTENNAS NO SCALE CADWELD 6" ABW CA[ 1 VERTICAL POST CONNECTED TO RING GROUND RING 5-1 EXISTING FENCE GROUNDING NO SCALE X cingular WIRELESS VelociTel r. LA CLOUGH. HARBOUR &ASSOCIATES LLP Ate,.,,=mss toeoo Ri..... o, VA 232- ui1E 103 CNA PROJECT NO: 12760 —1030 — 1601 N0. SUBMITTAL 1 04/23/04 85% CAD _ BY: CMM I CHK MJO APP'D:WLR 2 05/26/04 JISSUED FOR REVIEW BY: CMM I CHK:MJO APP'D:WLR 1 '1 Acerb IT IS AIT IS A VIDLATIONyeOF LAVs FOR ANY PERSONLA`M1 FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SITE ID: CINGULAR # 1253 SITE NAME: SHENANDOAH UNIVERSITY SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE ELECTRICAL DETAILS SHEET NUMBER E06 ELECTRICAL GENERAL NOTES 1. GENERAL A. EXAMINE THE SITE CONDITIONS VERY CAREFULLY AND THE SCOPE OF PROPOSED WORK TOGETHER WITH THE WORK OF ALL OTHER TRADES AND INCLUDE IN THE BID PRICE ALL COSTS FOR WORK SUCH AS EQUIPMENT AND WIRING MADE NECESSARY TO ACCOMMODATE THE ELECTRICAL SYSTEMS SHOWN AND SYSTEMS OF OTHER TRADES. B. SUBMITTAL OF BID INDICATES CONTRACTOR IS COGNIZANT OF ALL JOB SITE CONDITIONS AND WORK TO BE PERFORMED UNDER THIS CONTRACT. C PERFORM DETAILED VERIFICATION OF WORK PRIOR TO ORDERING THE ELECTRICAL EQUIPMENT AND COMMENCING CONSTRUCTION. ISSUE A WRITTEN NOTICE TO CINGULAR REPRESENTATIVE OF ANY DISCREPANCIES. D. SCHEDULE INSPECTION. OBTAIN PERMITS. E. PROVIDE ALL LABOR, MATERIAL, EQUIPMENT, INSURANCE AND SERVICES TO COMPLETE THIS PROJECT IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND PRESENT IT AS FULLY OPERATIONAL TO THE SATISFACTION OF THE OWNER. F. CARRY OUT WORK IN ACCORDANCE WITH ALL GOVERNING STATE, COUNTY AND LOCAL CODES AND O.S.H.A. G. CINGULAR REPRESENTATIVE WILL COORDINATE POWER AND TELCO WORK WITH THE LOCAL UTILITY COMPANY AS IT MAY APPLY TO THIS SITE. THIS INCLUDES CABLE LOCATION AND ROUTING OF SERVICE CABLES, REQUESTS FOR SERVICE, AND SPECIFIC SITE REQUIREMENTS OF THE UTILITY COMPANY. ALL WORK TO COMPLY WITH THE RULE AND REGULATIONS OF THE UTILITIES INVOLVED. H. FABRICATION AND INSTALLATION OF THE COMPLETE ELECTRICAL SYSTEM SHALL BE DONE IN A FIRST CLASS WORKMANSHIP PER NECA STANDARD 1-2000 BY QUALIFIED PERSONNEL EXPERIENCED IN SUCH WORK AND SHALL SCHEDULE THE WORK IN AN ORDERLY MANNER SO AS NOT TO IMPEDE PROGRESS OF THE PROJECT. I. DURING PROGRESS OF THE WORK, MAINTAIN AN ACCURATE RECORD OF THE INSTALLATION OF THE ELECTRICAL SYSTEMS. LOCATING EACH CIRCUIT PRECISELY AND DIMENSIONING EQUIPMENT, CONDUIT AND CABLE LOCATIONS. UPON COMPLETION OF THE INSTALLATION, TRANSFER ALL RECORD DATA TO RED LINE PRINTS OF THE ORIGINAL DRAWINGS AND SUBMIT THESE DRAWINGS AS RECORD DRAWINGS TO CINGULAR REPRESENTATIVE. J. COMPLETE JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER THE DATE OF JOB ACCEPTANCE BY OWNER. ANY WORK, MATERIAL OR EQUIPMENT FOUND TO BE FAULTY DURING THAT PERIOD SHALL BE CORRECTED AT ONCE, UPON WRITTEN NOTIFICATION, AT THE EXPENSE OF THE CONTRACTOR. K. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED PERMITS, BUILDING AUTHORITY INSPECTIONS, CORRECTIONS OF DEFECTS AND SCHEDULING FINAL POWER CONNECTION TO THE SITE FROM THE LOCAL UTILITY COMPANY. L. THE CONTRACTOR SHALL NOTIFY MISS UTILITY A MINIMUM OF 3 WORKING DAYS PRIOR TO ANY CONSTRUCTION OR EXCAVATION. THE CONTRACTOR SHALL ALSO NOTIFY A PRIVATE UTILITY CONTRACTOR FOR ALL ON-SITE UTILITY LOCATIONS. 2. BASIC MATERIALS AND METHODS A. ALL ELECTRICAL WORK SHALL CONFORM TO THE EDITION OF THE NEC ACCEPTED BY THE LOCAL JURISDICTION AND TO THE APPLICABLE LOCAL CODES AND REGULATIONS. B. ALL MATERIALS AND EQUIPMENT SHALL BE NEW. MATERIALS AND EQUIPMENT SHALL BE THE STANDARD PRODUCTS OF MANUFACTURER'S CURRENT DESIGN. ANY FIRST-CLASS PRODUCT MADE BY A REPUTABLE MANUFACTURER MAY BE USED PROVIDING IT CONFORMS TO THE CONTRACT REQUIREMENTS AND MEETS THE APPROVAL OF THE CONSULTANT AND THE OWNER. C. ARRANGE CONDUIT, WIRING, EQUIPMENT, AND OTHER WORK GENERALLY AS SHOWN. PROVIDING PROPER CLEARANCES AND ACCESS. CAREFULLY EXAMINE ALL CONTRACT DRAWINGS AND FIT THE WORK IN EACH LOCATION WITHOUT SUBSTANTIAL ALTERATION. WHERE DEPARTURES ARE PROPOSED BECAUSE OF FIELD CONDITIONS OR OTHER CAUSES PREPARE AND SUBMIT DETAILED DRAWINGS FOR ACCEPTANCE. D. THE CONTRACT DRAWINGS ARE GENERALLY DIAGRAMMATIC AND ALL OFFSETS, BENDS, FITTINGS AND ACCESSORIES ARE NOT NECESSARILY SHOWN. PROVIDE ALL SUCH ITEMS AS MAY BE REQUIRED TO FIT THE WORK TO THE CONDITIONS. E. MAINTAIN ALL CLEARANCES AS REQUIRED BY NATIONAL ELECTRICAL CODE (NEC). 3. CONDUCTORS AND CONNECTORS A. UNLESS NOTED OTHERWISE, ALL CONDUCTORS SHALL BE COPPER. MINIMUM SIZE #12 AWG. WITH THERMOPLASTIC INSULATION CONFORMING TO NEMA WC5 OR CROSS-LINKED POLYETHYLENE INSULATION CONFORMING TO NEMA WC7. (TYPES THHN OR THWN). INSULATION SHALL BE RATED FOR 90'C CONDUCTORS SHALL BE COLOR CODED IN ACCORDANCE WITH NEC. B. ALL CONDUCTORS USED FOR CIRCUIT GROUNDING SHALL BE COPPER AND SHALL HAVE GREEN INSULATION. C. FOR COPPER CONDUCTORS #6 AWG AND SMALLER USE 3M SCOTCH LOK OR T&B STA-KON COMPRESSION TYPE CONNECTORS WITH INTEGRAL OR SEPARATE INSULATION CAPS. FOR COPPER CONDUCTORS LARGER THAN #6 AWG USE SOLDERLESS.IDENT HEX SCREW OR BOLT TYPE PRESSURE CONNECTORS OR DOUBLE COMPRESSION C -CLAMP CONNECTORS_ UNLESS SPECIFIED OTHERWISE ON DRAWINGS. D. UNLESS NOTED OTHERWISE ALL LUGS SHALL BE TIN PLATED COPPER, TWO -HOLE. LONG BARREL COMPRESSION TYPE. E. CONDUCTOR LENGTHS SHALL BE CONTINUOUS FROM TERMINATION TO TERMINATION WITHOUT SPLICES. SPLICES ARE NOT ACCEPTABLE. IF SPLICES ARE UNAVOIDABLE PRIOR APPROVAL FROM THE ENGINEER MUST BE OBTAINED. 4. RACEWAYS AND BOXES A. ALL CONDUIT SHALL BE UL LABELED. B. ALL EMPTY CONDUITS INSTALLED FOR FUTURE USE SHALL HAVE A PULL CORD. C. SHEET METAL BOXES SHALL BE NEMA 3R AND CONFORM TO NEMA OS1; CAST -METAL BOXES SHALL BE NEMA 3R AND CONFORM TO NEMA 81 AND SHALL BE SIZED IN ACCORDANCE WITH NEC UNLESS NOTED OTHERWISE. 5. GROUNDING A. ALL SAFETY GROUNDING OF THE ELECTRICAL EQUIPMENT SHALL BE CARRIED OUT IN ACCORDANCE WITH THE CURRENT REVISION NATIONAL ELECTRICAL CODE. B. ALL CELLULAR SITE GROUNDING SHALL BE CARRIED OUT IN ACCORDANCE WITH CINGULAR REPRESENTATIVE REPRESENTATIVE WIRELESS GROUNDING STANDARD DATED OCTOBER 2001. C. GROUND LUGS ARE SPECIFIED UNDER SECTION 3 "CONDUCTORS AND CONNECTORS". D. ALL GROUND LUG AND COMPRESSION CONNECTIONS SHALL BE COATED WITH ANTI -OXIDANT AGENT SUCH AS NO -OX NOALOX, PENETROX OR KOPRSHIELD. E. PROVIDE LOCK WASHERS FOR ALL MECHANICAL CONNECTIONS FOR GROUND CONDUCTORS. USE STAINLESS STEEL HARDWARE THROUGHOUT. F. DO NOT INSTALL GROUND RING (IF REQUIRED) OUTSIDE OF PROPERTY LINE. G. REMOVE ALL PAINT AND CLEAN ALL DIRT FROM SURFACES REQUIRING GROUND CONNECTIONS REPAINT TO MATCH AFTER CONNECTIONS IS MADE 70 MAINTAIN CORROSION RESISTANCE. H. ALL EXTERIOR GROUNDING CONDUCTORS INCLUDING EXTERIOR GROUND RING (IF REQUIRED) SHALL BE #2 AWG SOLID BARE TINNED COPPER. MAKE ALL GROUND CONNECTIONS AS SHORT AND DIRECT AS POSSIBLE. AVOID SHARP BENDS. THE RADIUS OF ANY BEND SHALL NOT BE LESS THAN B" AND THE ANGLE OF ANY BEND SHALL NOT EXCEED 90 GROUNDING CONDUCTORS SHALL BE ROUTED DOWNWARD TOWARD THE BURIED GROUND RING. I. REPAIR ALL GALVANIZED SURFACES THAT HAVE BEEN DAMAGED BY EXOTHERMIC WELDING USE GOLD GALVANIZING SPRAY CONTAINING 95% ZINC (Z.R.C. "GALVILITE" OR EQUIVALENT). J. ALL GROUND CONNECTIONS SHALL BE APPROVED FOR THE METALS BEING CONNECTED. K. ALL EXTERNAL GROUND CONNECTIONS SHALL BE EXOTHERMICALLY WELDED. ALL EXOTHERMIC WELDS TO THE EXTERIOR GROUND RING SHALL BE TEE TYPE LOCATED ON TOP OF GROUND RODS. REPAIR ALL GALVANIZED SURFACES THAT HAVE BEEN DAMAGED BY EXOTHERMIC WELDING USE SPRAY ON GALVANIZER SUCH AS ZRC GALVILITE. L. IF NEW GROUND RING IS REQUIRED, CONTACTOR SHALL NOTIFY CINGULAR REPRESENTATIVE WHEN THE BURIED GROUND RING IS INSTALLED SO THE REPRESENTATIVE CAN INSPECT THE GROUND RING BEFORE IT IS BACKFILLED WITH SOIL. CONTACT CINGULAR REPRESENTATIVE REPRESENTATIVE. M. FOR METAL FENCE POST GROUNDING, USE AN EXOTHERMIC WELD CONNECTION TO POST. N. WHERE MECHANICAL CONNECTORS (TWO HOLE OF CLAMP) ARE USED, APPLY A LIBERAL PROTECTIVE COATING OF AN ANTI -OXIDE COMPOUND SUCH AS "NO OXIDE A" BY DEARBORN CHEMICAL COMPANY ON ALL CONNECTORS. 0. BOND ALL EXTERIOR CONDUITS, PIPES AND CYLINDRICAL METALLIC OBJECTS WITH A PENN -UNION GT SERIES CLAMP, BLACKBURN GUV SERIES CLAMP OR A BURNDY GAR 3900BU SERIES CLAMP ONLY, NO SUBSTITUTES ACCEPTED. P. TOWER GROUND RING, AND ASSOCIATED GROUND RODS AND INSPECTION SLEEVES ARE EXISTING. CONTRACTOR SHALL FIELD VERIFY THAT NEW GROUND RING AROUND NEW EQUIPMENT PAD, NEW GROUND RODS, NEW INSPECTION SLEEVES AND CONNECTIONS TO TOWER GROUND RING CONFORM WITH THE DETAILS SHOWN ON THE DRAWINGS. ON SITES REQUIRING EQUIPMENT PAD MODIFICATIONS, CONTACTOR SHALL ENSURE THAT EXISTING GROUND RING MEETS DESIGN CRITERIA SHOWN ON DRAWINGS. CONTRACTOR SHALL PROVIDE, AS REQUIRED, MODIFICATIONS TO EXISTING GROUNDING AND ANY ADDITIONAL GROUNDING REQUIRED TO MEET THE DESIGN CRITERIA INDICATED ON THE DRAWINGS. Q. PERFORM A GROUND RESISTANCE MEASUREMENT OF THE GROUNDING SYSTEM USING THE "FALL OF POTENTIAL METHOD". THE RESISTANCE BETWEEN ANY POINT ON THE GROUND SYSTEM AND THE REFERENCE GROUND SHALL BE 5 OHMS OR LESS. ENSURE THAT THE ELECTRIC UTILITY AND TELCO GROUNDS ARE REMOVED FROM THE CELLULAR SYSTEM GROUNDING. R. INSTALL GROUND RODS EVERY 10'. Xcingularry WIRELESS »So sTnt Ro —.. NANOVER neo. —1. VelociTel L_ •AI CLOUGH. HARBOUR S ASSOCIATES LLP ElVGn'EFFS. FiAnfEtS s I_wvExriwE �r-,o-.re�*s ,oeoo AR T E. so�rE X03 RICI—ND. A 23-5 CHA PROJECT NO: 12760 - 1030 - 1601 N0. SUBMITTAL 1 04/23/04 85% CAD BY: CMM I CHK: MJO APP'D: WLR 2 05/26/04 JISSUED FOR REVIEW BY: CMM I CHK: MJO APP'D: WLR r=' S 0, ➢ ' 1 �r A a ..... IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SITE ID: CINGULAR # 1253 SITE NAME: - SHENANDOAH UNIVERSITY SITE ADDRESS: 1460 UNIVERSITY DRIVE WINCHESTER, VA 22601 FREDERICK COUNTY SHEET TITLE ELECTRICAL SPECIFICATIONS SHEET NUMBER E08