Loading...
HomeMy WebLinkAbout37-17 Site PlanSITE NOT FOR CONSTRUCTION CS0001 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y PA R K I N G S T R U C T U R E S P # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y CO V E R S H E E T HOSH1701 AS SHOWN JDS MMA SHEET OF1 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K PREPARED FOR: OWNER/DEVELOPER SHENANDOAH UNIVERSITY 1460 UNIVERSITY DRIVE WINCHESTER, VIRGINIA 22601 (540) 665-4527 SHENANDOAH UNIVERSITY PARKING STRUCTURE SP #37-17 ¬ SITE PLAN ¬ SHAWNEE DISTRICT, FREDERICK COUNTY, VIRGINIA SEPTEMBER 28, 2017 ¬ LOCATION MAP Scale: 1" = 2000' USGS MAP Scale: 1" = 2000'                             CALL 1-800-552-7001 CALL BEFORE YOU DIG ALWAYS CALL 811 BEFORE YOU DIG IN VIRGINIA SECTION 56-265.17 REQUIRES THREE WORKING DAYS NOTICE TO UTILITIES BEFORE YOU EXCAVATE, DRILL OR BLAST VIRGINIA UTILITY PROTECTION SERVICE, INC. TICKET NUMBER(S):  PREPARED BY: PENNONI ASSOCIATES INC. 117 East Piccadilly Street Winchester, VA 22601 T 540.667.2139 F 540.665.0493 TMP 54-A-141A Property Zoned: HE Proposed Use: Parking Garage 1025 RALPH SHOCKEY DRIVE APPROVED BY FREDERICK COUNTY ZONING ADMINISTRATOR REVISED: OCTOBER 25, 2017 Sheet List Table Sheet Number Sheet Title 1 COVER SHEET 2 NOTES AND LEGENDS 3 EXISTING CONDITIONS & DEMOLITION PLAN 4 OVERALL SITE PLAN 5 SITE PLAN 6 GRADING PLAN 7 UTILITY PLAN 8 UTILITY PROFILES 9 UTILITY PROFILES 10 UTILITY DETAILS 11 STORM SEWER CALCULATIONS 12 ENTRANCE ROAD PLAN & PROFILE 13 EROSION & SEDIMENT CONTROL PH.1 14 EROSION & SEDIMENT CONTROL PH.2 15 EROSION AND SEDIMENT CONTROL NARRATIVE AND DETAILS 16 ON-SITE PRE AND POST DEVELOPMENT DRAINAGE AREA MAP 17 ON-SITE OFF-SITE POST DEVELOPMENT DRAINAGE ANALYSIS 18 STUDY POINT WATERSHED 19 BIORETENTION PLAN 20 BIORETENTION DETAILS 21 BIORETENTION CALCULATIONS 22 LIGHTING PLAN 23 FIRE LANE AND SIGNAGE PLAN 24 FIRE LANE DETAILS 25 LANDSCAPE PLAN 26 LANDSCAPE DETAILS 27 SITE DETAILS 28 SITE DETAILS NOT FOR CONSTRUCTION CS0002 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y NO T E S A N D L E G E N D S HOSH1701 1"= JDS MMA SHEET OF2 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K                             HY D *A Waiver is required from the Board of Supervisiors for any building proposed to be higher than forty five (45) feet. In no case shall any structure exceed seventy-five (75) feet in height. 1. PRIOR TO INITIATING ANY LAND DISTURBING ACTIVITY, IT WILL BE NECESSARY TO SCHEDULE AN ON-SITE PRE-CONSTRUCTION MEETING WITH PUBLIC WORKS STAFF TO DISCUSS THE APPROVED EROSION AND SEDIMENT CONTROL PLAN. NO PRE-CONSTRUCTION MEETINGS WILL BE SCHEDULED PRIOR TO ISSUANCE OF THE LAND DISTURBANCE PERMIT FOR THE SUBJECT PROJECT. THE LAND DISTURBANCE PERMIT WILL BE ISSUED BY THE FREDERICK COUNTY DEPARTMENT OF PUBLIC WORKS. 2. CONTRACTOR TO CONTACT THE PUBLIC WORKS DEPARTMENT TO SCHEDULE THE REQUIRED EROSION AND SEDIMENT CONTROL MEASURES INSPECTIONS AS INDICATED BY THE PROGRAM ADMINISTRATOR. IF THE EROSION AND SEDIMENT CONTROL MEASURERS HAVE BEEN INSTALLED IN ACCORDANCE WITH THE APPROVED PLAN, THE DEPARTMENT OF PUBLIC WORKS WILL GRANT APPROVAL TO INITIATE LAND DISTURBING ACTIVITIES. 3. PRIOR TO RELEASE OF BUILDING PERMITS, THE FOLLOWING ITEMS SHALL BE COMPLETED: A) SUBDIVISION SHALL BE STABILIZED IN ACCORDANCE WITH THE APPROVED PLAN (I.E., ROAD SURFACE, STORMWATER CONVEYANCE SYSTEM, CURB AND GUTTER, SIDEWALKS, CHANNEL LININGS, VEGETATIVE COVER, STC.) B) SUBMITTAL OF CERTIFIED AS-BUILT OF THR SUBDIVISION WHICH CONTAINS THE FOLLOWING ITEMS: STORMWATER CONVEYANCE SYSTEM, CURB AND GUTTER, DRAINAGE CHANNELS AND DITCHES, STORMWATER POND. A LETTER FROM THE ENGINEER-OF-RECORD SHALL BE INCLUDED WITH THE AS-BUILT WHICH STATES THAT THE SUBDIVISION HAS BEEN CONSTRUCTED IN ACCORDANCE WITH THE APPROVED PLAN. C) INDIVIDUAL SUBDIVISION LOT GRADING PLANS SHALL BE SUBMITTED BY THE BUILDER AT THE TIME OF THE BUILDING PERMIT APPLICATION FOR EACH LOT PROPOSED FOR CONSTRUCTION. 4. TEMPORARY AND PERMANENT EROSION CONTROL STRUCTURES AND METHODS TO BE IN ACCORDANCE WITH THE VIRGINIA EROSION CONTROL GUIDELINES AND LOCAL ORDINANCES AND TO BE UTILIZED DURING THE CONSTRUCTION PERIOD. 5. ALL EROSION CONTROL STRUCTURES SHOWN OR AS REQUIRED DURING CONSTRUCTION SHALL BE CONTINUOUSLY MAINTAINED THROUGHOUT THE PERIOD IN WHICH AREAS ARE DENUDED. AREAS SHOWN TO BE SURFACED ARE TO HAVE STONE BASE INSTALLED AT THE EARLIEST POSSIBLE DATE AFTER ESTABLISHING GRADE. NO AREA IS TO REMAIN DENUDED FOR MORE THAN 7 CALENDAR DAYS WHEN CONSTRUCTION IS NOT IN PROGRESS. 6. CONTRACTOR TO CLEAN UP AND RESTORE DISTURBED AREAS IMMEDIATELY UPON COMPLETION OF PIPE-LAYING IN THE AFFECTED AREA. 7. ALL UNPAVED AREAS OF THE SITE WHICH ARE DISTURBED BY THIS CONSTRUCTION SHALL BE PROVIDED WITH 6" TOPSOIL, FERTILIZED, SEEDED, COMPACTED AND MULCHED. SEED BED TO BE WATERED AND CARED FOR AS NECESSARY TO PROVIDE A GOOD LAWN QUALITY GRASS COVER. AREAS NOT GRADED SHALL BE DISCED, LEVELED AND SEEDED TO ACHIEVE LAWN CONDITIONS. EXIS T I N G BUIL D I N G INT E R S T A T E 8 1 RA L P H S H O C K E Y D R I V E EX I S T I N G F L O O D W A Y 10 0 Y E A R F L O O D P L A I N EX I S T I N G F L O O D W A Y EXISTING WATERLINE AB R A M S C R E E K 50' B R L 35 ' B R L 25' BRL EXISTING SCOREBOARD TO BE REMOVED EXISTING SPRINKLER CONTROL BOXES TO BE REMOVED EXISTING WELL CAP TO BE REMOVED & ABANDONED NOT FOR CONSTRUCTION CS0201 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y EX I S T I N G C O N D I T I O N S & D E M O L I T I O N P L A N HOSH1701 1"=40' JDS MMA SHEET OF3 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 40'80' NORTH                             ABBREVIATION DEFINITION CORRUGATED METAL PIPE DRAINAGE MANHOLE ELECTRIC MANHOLE INVERT METAL LIGHT POLE METAL POST METAL SIGN POST SANITARY MANHOLE SPRINKLER CONTROL BOX WATER METER WATER VALVE LEGEND FENCE 18 SPACES 18 SPACES 21 SPACES 24 SPACES 20.00' 2 2 . 0 0 ' 2 0 . 0 0 ' 2 0 . 0 0 ' 2 2 . 0 0 ' 2 0 . 0 0 ' 20.00' 20.00' 2 0 . 0 0 ' 9' 9' 22.00' 2 0 . 0 0 ' 22.00' 5 0 ' C L R A D I U S 24" SWSC 50'R. 50'R. 5 0 ' R . 12" STORM PIPE (WITH PARKING GARAGE)12" STORM PIPE E PROPOSED ELECTRIC SERVICE ELECTRIC SERVICE TO BE EXTENDED FROM EXISTING SERVICE AT FOOTBALL STADIUM. 20 FT. WATER EASEMENT PROPOSED STOP SIGN AND STOP BAR PROPOSED BIORETENTION BASIN B PROPOSED BIORETENTION BASIN A 8.0' 2' X4' CONCRETE FLUME 2' CURB CUT M METAL PLATE COVER OVER FLUME. SEE DETAIL-SHEET 27. 20 FT. WATER EASEMENT 4.00'4.00' 4 FT. CONC. SIDEWALK INTE R S T A T E 8 1 RA L P H S H O C K E Y D R I V E EX I S T I N G F L O O D W A Y 10 0 Y E A R F L O O D P L A I N EX I S T I N G F L O O D W A Y EXISTING WATERLINE AB R A M S C R E E K 50' B R L 35 ' B R L 25' BRL 0+0 0 1 + 0 0 2+ 0 0 3+00 4+00 5+00 5 + 8 1 0 + 0 0 1+ 0 0 1+ 2 4 2 0 . 5 9 ' 1 4 8 . 9 9 ' 6 6 . 0 6 ' 8 3 . 7 0 ' 3 7 . 9 5 ' 187 . 5 9 ' NOT FOR CONSTRUCTION CS1001 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y OV E R A L L S I T E P L A N HOSH1701 1"= 40' JDS MMA SHEET OF4 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 40'80'                             PE N N O N I A S S O C I A T E S I N C . ABBREVIATION DEFINITION CORRUGATED METAL PIPE DRAINAGE MANHOLE ELECTRIC MANHOLE INVERT METAL LIGHT POLE METAL POST METAL SIGN POST SANITARY MANHOLE SPRINKLER CONTROL BOX WATER METER WATER VALVE LEGEND FENCE NORTH 18 SPACES 18 SPACES 21 SPACES 24 SPACES 20.00' 2 2 . 0 0 ' 2 0 . 0 0 ' 2 0 . 0 0 ' 2 2 . 0 0 ' 2 0 . 0 0 ' 20.00' 20.00' 2 0 . 0 0 ' 9' 9' 22.00' 2 0 . 0 0 ' 22.00' 5 0 ' C L R A D I U S 24" SWSC 50'R. 50'R. 5 0 ' R . 12" STORM PIPE (WITH PARKING GARAGE)12" STORM PIPE E PROPOSED ELECTRIC SERVICE ELECTRIC SERVICE TO BE EXTENDED FROM EXISTING SERVICE AT FOOTBALL STADIUM. 20 FT. WATER EASEMENT PROPOSED STOP SIGN AND STOP BAR PROPOSED BIORETENTION BASIN B PROPOSED BIORETENTION BASIN A 8.0' 2' X4' CONCRETE FLUME 2' CURB CUT M METAL PLATE COVER OVER FLUME. SEE DETAIL-SHEET 27. 20 FT. WATER EASEMENT 4.00'4.00' 4 FT. CONC. SIDEWALK INT E R S T A T E 8 1 RA L P H S H O C K E Y D R I V E EX I S T I N G F L O O D W A Y 10 0 Y E A R F L O O D P L A I N EX I S T I N G F L O O D W A Y EXISTING WATERLINE AB R A M S C R E E K 50' B R L 35 ' B R L 25' BRL 0+0 0 1 + 0 0 2+0 0 3+00 4+00 5+00 5 + 8 1 2 0 . 5 9 ' 1 4 8 . 9 9 ' 6 6 . 0 6 ' 8 3 . 7 0 ' 3 7 . 9 5 ' 287.33' 1 2 2 . 8 3 ' 187 . 5 9 ' NOT FOR CONSTRUCTION CS1002 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y SI T E P L A N HOSH1701 1"=30' JDS MMA SHEET OF5 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 30'60' NORTH                             PE N N O N I A S S O C I A T E S I N C . Maximum cross slope of a walking surface is 1:48, per ANSI A117.1 Section 403.3. ASPHALT PAVEMENT SECTION FOR STD. DUTY CONCRETE SIDEWALK SECTION ASPHALT PAVEMENT SECTION FOR HEAVY DUTY INT E R S T A T E 8 1 RA L P H S H O C K E Y D R I V E EX I S T I N G F L O O D W A Y 10 0 Y E A R F L O O D P L A I N EX I S T I N G F L O O D W A Y EXISTING WATERLINE AB R A M S C R E E K 50' B R L 35 ' B R L 25' BRL 18 SPACES 18 SPACES 21 SPACES 24 SPACES 20.00' 2 2 . 0 0 ' 2 0 . 0 0 ' 2 0 . 0 0 ' 2 2 . 0 0 ' 2 0 . 0 0 ' 20.00' 20.00' 2 0 . 0 0 ' 9' 9' 22.00' 2 0 . 0 0 ' 22.00' 5 0 ' C L R A D I U S 24" SWSC 50'R. 50'R. 5 0 ' R . 12" STORM PIPE (WITH PARKING GARAGE)12" STORM PIPE E 20 FT. WATER EASEMENT PROPOSED STOP SIGN AND STOP BAR PROPOSED BIORETENTION BASIN B PROPOSED BIORETENTION BASIN A 8.0' 2' X4' CONCRETE FLUME 2' CURB CUT M METAL PLATE COVER OVER FLUME. SEE DETAIL-SHEET 27. 20 FT. WATER EASEMENT 4.00'4.00' 4 FT. CONC. SIDEWALK 670 674 672 674 64 8 646 6 5 0 652 676 6 4 4 64 6 668 x672.5 x 672.5 0.9 5 % 672 672 671 Point of Analysis Q2 Peak = 11.98 CFS Q10 Peak = 30.09 CFS V2 = 3.77 ft/s Q10 confined in channel 0+00 1+00 1+38 0+0 0 1 + 0 0 2+ 0 0 3+00 4+00 5+00 5 + 8 1 0 + 0 0 1 + 0 0 1 + 1 0 0+ 0 0 1+ 0 0 2+ 0 0 3+ 0 0 3+ 2 2 0 + 0 0 1+ 0 0 1+ 2 4 2 0 . 5 9 ' NOT FOR CONSTRUCTION CS1501 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y GR A D I N G P L A N HOSH1701 1"=30' JDS MMA SHEET OF6 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 30'60' NORTH                             NOTE: Retaining Walls that support 3 ft. or more of unbalanced fill require a building permit and inspections. 2012 VCC 108.2(7). FEMA FLOODWAY & 100 YEAR FLOOD PLAIN SHOWN HEREON IS TAKEN FROM FREDERICK COUNTY G.I.S. NO LAND DISTURBANCE OR IMPROVEMENTS ARE PROPOSED WITHIN THE FLOODWAY. [ƒ%(1' 1-8"X22 1 2ƒ%(1' 24" SWSC 50'R. 50'R. 5 0 ' R . RELOCATED WATER VALVE EXTEND NON-POTABLE WATER SERVICE FOR IRRIGATION ONLY 12" STORM PIPE (WITH PARKING GARAGE)12" STORM PIPE [ƒ%(1' 1-8"TAPPING SLEEVE SEE DETAIL ON SHEET 9 E RELOCATED STREET LIGHT AND ELECTRICAL MANHOLE 8" DI CL52 WATER LINE PROPOSED ELECTRIC SERVICE ELECTRIC SERVICE TO BE EXTENDED FROM EXISTING SERVICE AT FOOTBALL STADIUM. 20 FT. WATER EASEMENT PROPOSED BIORETENTION BASIN B PROPOSED BIORETENTION BASIN A 1-FIRE HYD. ASSEMBLY M 20 FT. WATER EASEMENT INT E R S T A T E 8 1 RA L P H S H O C K E Y D R I V E EX I S T I N G F L O O D W A Y 10 0 Y E A R F L O O D P L A I N EX I S T I N G F L O O D W A Y EXISTING WATERLINE AB R A M S C R E E K 50' B R L 35 ' B R L 25' BRL 0+00 1+00 1+38 0+0 0 1 + 0 0 2+0 0 3+00 4+00 5+00 5 + 8 1 0 + 0 0 1 + 0 0 1 + 1 0 0+ 0 0 1+ 0 0 2+ 0 0 3+ 0 0 3+ 2 2 0 + 0 0 1+ 0 0 1+ 2 4 2 0 . 5 9 ' NOT FOR CONSTRUCTION CS1701 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y UT I L I T Y P L A N HOSH1701 1"=30' JDS MMA SHEET OF7 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 30'60' NORTH                             PE N N O N I A S S O C I A T E S I N C . PROPOSED WATER LINE 5+00 HORIZONTAL SCALE: 1" = 30' VERTICAL SCALE: 1" = 3' 635 640 645 650 655 660 665 670 675 635 640 650 660 670 -0+25 0+00 64 5 . 2 64 5 . 2 2 64 6 . 7 64 6 . 6 9 1+00 64 6 . 1 64 6 . 1 4 65 3 . 5 65 3 . 4 7 2+00 66 4 . 4 66 4 . 4 1 66 7 . 0 66 6 . 9 7 3+00 67 1 . 9 67 1 . 8 8 67 2 . 6 67 2 . 5 8 4+00 67 2 . 9 67 2 . 8 8 67 3 . 5 67 3 . 5 5 5+00 67 3 . 4 67 3 . 4 2 67 3 . 3 67 3 . 3 0 5+85 STA:0+14.93 EX. 8" WATER LINE TAPPING SLEEVE 2-8" GATE VALVES 8" DI CL52 WATER LINE MI N . 3 ' C O V E R FINISHED GRADE EXISTING GROUND RALPH SHOCKEY DRIVE STA:0+48.15 ;ƒ%(1' TWO-24" HDPE PIPES 18 " MI N . STA:1+32.51 ;ƒ%(1' STA:1+36.73 ;ƒ%(1' STA:1+91.67 ;ƒ%(1' STA:5+80.83 1-FIRE HYD. ASSEMBLY 6" DI CL52 WATER LINE MI N . 3 ' C O V E R FINISHED GRADE EMERGENCY ACC. RD. STA:2+42.26 ;ƒ%(1' STA:2+16.40 1-8"x8" TEE 3-8" G.V.'s 1-8"X6" REDUCER STA:1+98.21 1-FIRE HYD. ASSEMBLY STA:5+46.97 6" ROOF DRAIN STA:5+53.11 ;ƒ%(1' C-WATER-LATERAL TO GARAGE HORIZONTAL SCALE: 1" = 30' VERTICAL SCALE: 1" = 3' 645 650 655 660 665 670 675 680 645 650 660 670 680 0+00 66 4 . 9 66 4 . 8 9 0+50 5 8" WATER LINE GARAGE STRUCTURE WALL GARAGE FLOOR 5 8" WATER METER 1-8"X8" TEE 3-8" GATE VALVES STA:0+17.60 1-8"X5/8"TEE 1-5/8" G.V. 1-5/8" G.V. 6" ROOF DRAIN 5 8" WATER LINE PROPOSED GRADE EXISTING GROUND NOT FOR CONSTRUCTION CS4001 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y UT I L I T Y P R O F I L E S HOSH1701 1"=30' JDS MMA SHEET OF8 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 30'60'                             STORM PROFILE 1 5+00 HORIZONTAL SCALE: 1" = 30' VERTICAL SCALE: 1" = 3' 648 650 660 670 680 0+00 65 0 . 3 65 0 . 3 3 65 6 . 8 65 6 . 7 9 1+00 66 3 . 4 66 3 . 3 9 66 9 . 2 66 9 . 2 3 2+00 67 4 . 5 67 4 . 5 1 67 5 . 2 67 5 . 1 8 3+00 67 5 . 7 67 5 . 7 4 3+75 EXISTING GROUND 157' OF 15" ADS N-12 @ 0 . 6 7 % 67' OF 1 5 " A D S N - 1 2 @ 3 . 0 0 % FINISHED GRADE ST R 2 1 8 " N Y L O P L A S T D R A I N B A S I N GR A T E 6 6 4 . 3 0 IN V O U T 6 6 0 . 3 5 ( S T R 1 T O S T R 2 ) ST R 1 1 8 " N Y L O P L A S T J U N C T I O N GR A T E 6 6 4 . 0 0 IN V I N 6 5 8 . 3 5 ( S T R 1 T O S T R 2 ) IN V O U T 6 5 1 . 7 5 ( 1 5 E N D S E C T I O N T O S T R 1 ) STA:0+99.82 INV.OUT:654.60 CULVERT 6 15 E N D S E C T I O N 1 5 I N C M F E S IN V I N 6 5 0 . 7 0 ( 1 5 E N D S E C T I O N T O S T R 1 ) 24 " STA:1+90.76 ELEV:658.50 STA:1+90.76 ELEV:656.00FO O T E R 93' OF 8 " H D P E @ 3 . 9 7 % ST R 3 ( 1 ) 1 0 " N Y L O P L A S T D R A I N B A S I N RI S E R S T R U C T U R E # 3 W I T H L O C K I N G DO M E T R A S H R A C K GR A T E 6 6 8 . 5 0 IN V O U T 6 6 4 . 2 5 ( S T R 2 ( 2 ) T O S T R 3 ( 1 ) ) IN V . I N 6 6 4 . 2 5 STORM 2 4+00 HORIZONTAL SCALE: 1" = 30' VERTICAL SCALE: 1" = 3' 635 640 645 650 655 635 640 650 0+00 64 4 . 9 64 4 . 8 8 64 6 . 3 64 6 . 3 2 1+00 64 6 . 0 64 5 . 9 7 1+25 EXISTING GROUND FINISHED GRADE STORM 3 4+00 HORIZONTAL SCALE: 1" = 30' VERTICAL SCALE: 1" = 3' 650 655 660 665 670 650 660 670 -0+100+00 66 3 . 1 66 3 . 1 2 66 6 . 0 66 6 . 0 4 1+00 67 2 . 8 67 2 . 7 9 1+25 EXISTING GROUND FINISHED GRADE 80' OF 15" HDPE @ 1 . 0 2 % END SECTION INV. OUT=654.60 43' OF 6" PVC @ 1 . 0 0 % RO O F D R A I N F R O M P A R K I N G G A R A G E 18 " M I N . CL E A R TWO - 9 5 ' O F 2 4 " H D P E @ 2 . 6 2 % ST R 5 2 4 I N C M F E S IN V I N 6 4 3 . 5 0 ( S T R 5 T O S T R 4 ) ST R 4 2 4 I N C M F E S IN V O U T 6 4 6 . 0 0 ( S T R 5 T O S T R 4 ) ST R 6 4 8 " M H GR A T E 6 5 9 . 4 4 IN V I N 6 5 6 . 1 6 ( S T R 6 T O I - 2 8 ) IN V I N 6 5 5 . 5 0 ( 1 2 " F R O M G A R A G E ) IN V O U T 6 5 5 . 4 1 ( 2 4 E N D S E C T . T O S T R 6 ) 6" WATER EX STORM EXT 4+00 HORIZONTAL SCALE: 1" = 30' VERTICAL SCALE: 1" = 3' 660 665 670 675 680 660 670 680 0+00 66 6 . 9 66 6 . 9 5 67 4 . 1 67 4 . 0 6 1+00 67 5 . 2 67 5 . 2 2 1+50 101 L.F. 24 " C M P S T O R M P I P E FINISHED GRADE 16' OF 24" CMP @ 1.93% EN D S E C T I O N 2 4 I N C M F E S IN V I N 6 7 1 . 3 0 ( T O E N D S E C T I O N ) EXISTING GROUND NOT FOR CONSTRUCTION CS4001A BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y UT I L I T Y P R O F I L E S HOSH1701 1"=30' JDS MMA SHEET OF9 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 30'60'                             NOT FOR CONSTRUCTION CS4002 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y HOSH1701 NO SCALE JDS MMA SHEET OF10 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K                             UT I L I T Y D E T A I L S NOT FOR CONSTRUCTION CS6022 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y HOSH1701 NO SCALE JDS MMA SHEET OF11 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K                             ST O R M S E W E R C A L C U L A T I O N S R A L P H S H O C K E Y D R I V E E X I S T I N G F L O O D W A Y 1 0 0 Y E A R F L O O D P L A I N A B R A M S C R E E K 3 5 ' B R L 5 0 ' C L R A D I U S 24" S W S C 50 ' R . 50'R . 50'R . 12" S T O R M P I P E ( W I T H P A R K I N G G A R A G E ) 12" S T O R M P I P E E ELE C T R I C S E R V I C E T O B E EXT E N D E D F R O M E X I S T I N G SER V I C E A T F O O T B A L L STA D I U M . 20 F T . W A T E R EAS E M E N T PR O P O S E D S T O P S I G N AN D S T O P B A R PR O P O S E D BIO R E T E N T I O N BAS I N B 2' C U R B C U T M FLU M E . S E E D E T A I L - S H E E T 2 7 . 4.0 0 ' 648 64 6 650 652 644 6 4 6 66 8 0 . 9 5 % 0+00 1 + 0 0 2+00 3+ 0 0 3+6 2 STA 0+14.93 ELEV. 645.44 0+ 0 0 1+0 0 0+0 0 1+0 0 0+00 1+0 0 2 + 0 0 0 + 0 0 1 + 0 0 2 + 0 0 0+00 1+00 1+10 0+00 1+00 1+24 0 + 0 0 0 + 4 8 CL ENTR ROAD 6+00 HORIZONTAL SCALE: 1" = 30' VERTICAL SCALE: 1" = 3' 640 645 650 655 660 665 670 675 640 650 660 670 -0+20 0+00 64 5 . 8 64 5 . 7 9 64 7 . 3 64 7 . 3 4 1+00 64 7 . 8 64 7 . 7 8 64 6 . 9 64 6 . 9 2 2+00 65 3 . 1 65 3 . 1 2 65 9 . 5 65 9 . 4 8 3+00 66 4 . 4 66 4 . 3 8 67 3 . 7 67 3 . 7 0 3+75 LE V E L O N E - - P A R K I N G G A R A G E -1.98% 4.79% 1.00% ST A 0 + 1 4 . 9 3 EL E V 6 4 5 . 4 4 ST A 3 + 5 4 . 9 6 EL E V 6 6 0 . 0 0 PVI STA = 3+36.32 PVI ELEV = 659.81 A.D. = -3.79 K = 6.59 BV C S : 3 + 2 3 . 8 2 BV C E : 6 5 9 . 2 1 EV C S : 3 + 4 8 . 8 2 EV C E : 6 5 9 . 9 4 25' VC PVI STA = 0+30.07 PVI ELEV = 645.14 A.D. = +6.77 K = 3.69 BV C S : 0 + 1 7 . 5 7 BV C E : 6 4 5 . 3 9 EV C S : 0 + 4 2 . 5 7 EV C E : 6 4 5 . 7 4 LOW POINT ELEV = 645.31 LOW POINT STA = 0+24.88 25' VC RALPH SHOCKEY DRIVE PROPOSED ROAD GRADE EXISTING GROUND 660 ELEV. NOT FOR CONSTRUCTION CS3501 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y EN T R A N C E R O A D P L A N & P R O F I L E HOSH1701 1"=30' JDS MMA SHEET OF12 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 30'60' NO R T H                             INT E R S T A T E 8 1 RA L P H S H O C K E Y D R I V E EX I S T I N G F L O O D W A Y 10 0 Y E A R F L O O D P L A I N EX I S T I N G F L O O D W A Y AB R A M S C R E E K 50' B R L 35 ' B R L 25' BRL 670 672 654654 656 654 658 660 65 4 LIMITS OF DISTURBANCE LIMITS OF DISTURBANCE 2.45 AC. TO ST-B 0.88 AC. TO ST-A NOT FOR CONSTRUCTION CS8001 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y ER O S I O N & S E D I M E N T C O N T R O L P H . 1 HOSH1701 1"=30' JDS MMA SHEET OF13 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 30'60' NORTH                             Table 3.13 Sediment Trap Key Design Aspects Trap Number A B Drainage area 0.88 Ac.2.45 Ac. Wet Storage Req 59 cy 164 cy Wet Storage Prov 64 cy 171 cy Dry Storage Req 59 cy 164 cy Dry Storage Prov 66 cy 167 cy Weir Width 2.00 feet 2.00 feet Storage Depth 2.25 2.25 Cleanout Ele 666.38 650.13 base stone outlet ele 667.50 651.25 Trap Bottom Ele 665.25 649.00 crest stone outlet ele 669.00 653.00 Weir Length 2.25 14.60 RA L P H S H O C K E Y D R I V E EX I S T I N G F L O O D W A Y 10 0 Y E A R F L O O D P L A I N 50' B R L 35 ' B R L 25' BRL 41E29 24" SWSC 12" STORM PIPE (WITH PARKING GARAGE)12" STORM PIPE E PROPOSED BIORETENTION BASIN B PROPOSED BIORETENTION BASIN A M 670 674 672 674 64 8 646 6 5 0 652 676 6 4 4 64 6 668 x672.5 x 672.5 672 671 LIMITS OF DISTURBANCE LIMITS OF DISTURBANCE 0+0 0 1 + 0 0 2+ 0 0 3+00 4+00 5+00 5 + 8 1 2 0 . 5 9 ' NOT FOR CONSTRUCTION CS8002 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y ER O S I O N & S E D I M E N T C O N T R O L P H . 2 HOSH1701 1"=30' JDS MMA SHEET OF14 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 30'60' NORTH                             29 NOTES: SOIL DATA SCALE: 1"=30' NOT FOR CONSTRUCTION CS8003 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y HOSH1701 NO SCALE JDS MMA SHEET OF15 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K                             ER O S I O N A N D S E D I M E N T C O N T R O L NA R R A T I V E A N D D E T A I L S Permanent Stabilization: A permanent vegetative cover shall be established on denuded areas not otherwise permanently stabilized. Permanent stabilization shall not be considered established until a ground cover is achieved that, is uniform, mature enough to survive and will inhabit erosion (4VAC50-30-40 Minimum Standard No. 3). 3HUPDQHQW6WDELOL]DWLRQ$OOGLVWXUEHGDUHDVQRWSDYHGZLOOUHFHLYHDWDPLQLPXP´RIWRSVRLO if required (see Topsoiling STD &SPEC 3.30) and be seeded as follows: 125 lbs. Minimum of three (3) up to five (5) varieties of bluegrass from the approved list for use in Virginia. 20 lb. Annual Rye per ac. 1000 lbs. 10-20-10 Fertilizer per ac. 3 tons agricultural limestone per ac 2 tons straw mulch per ac. Permanent seeding will occur as a final phase of construction. Temporary Stabilization: Seeding to stabilize areas left denuded for more than seven days, but not yet at final grade shall be as follows: 60 lbs. German Millet per ac. (May through August 15) 60 lb. Annual Rye per ac. (August 15 through April) 450 lbs. 10-20-20 Fertilizer per ac. 3 tons agricultural limestone per ac 2 tons straw mulch per ac. Seeded areas to be watered and cared for as necessary to provide grass emergence. F.Description of Controls Control will be exercised through sequence of land disturbing operations, limiting duration of exposure of unstabilized areas and installation and maintenance of physical control devices coordinated with sequence of construction. Details for the standards referenced below are included on the plans. The devices to be used on the site are also shown on the drawings and include the following: 1. &RQVWUXFWLRQ6DIHW\)HQFH 67' 63(& ±2UDQJHZDUQLQJIHQFHVKDOOEH placed around the perimeter of the construction site in locations as directed by University Physical Plant staff. 2. &RQVWUXFWLRQHQWUDQFHV± 67' 63(& 7KHUHLVDKLJKSRWHQWLDOIRUWUDFNLQJ mud on to adjacent pavement during wet site conditions. Construction entrances are needed at the location shown on the plans to clean the tires of vehicles and equipment exiting the job site. 3. 6LOW)HQFH± 67' 63(& 6LOWIHQFLQJVKDOOEHSODFHGDVVKRZQRQWKHSODQLQ order to filter sediments before runoff exits the construction area. 4. Storm Drain Inlet Protection- (STD &SPEC 3.07) Storm drain inlet protection shall be installed immediately following installation of stormwater diversion to prevent sediment from entering the storm drains. 5. Culvert Inlet Protection- (STD & SPEC 3.08) Culvert inlet protection shall be installed as shown on the plan to prevent sediment from entering storm culverts. 6. Temporary Diversion Dike - (STD & SPEC 3.09) Temporary Diversion Dike shall be placed as shown on the plan to divert sediment-laden runoff to the proposed Temporary Sediment trap. 7. Temporary Sediment Traps - (STD & SPEC 3.13) Temporary Sediment Traps shall be installed as shown on plans to collect run-off during constuction and prevent sediment from depositing downstream. 8. Outlet Protection - (STD & SPEC 3.18) EC-1 required at outlet of Culvert 1, west of the site. 9. Rock Check Dams - (STD & SPEC 3.20) Rock Check Dams shall be installed as shown on the plans to prevent swale erosion. 10. Soil Stabilization Blankets and Matting - (STD & SPEC 3.36) Erosion Control Matting shall be installed on all slopes 4:1 or greater as shown on the plans to stabilize the soil and prevent erosion. G.Sequence of Land Disturbing Activities: 1.General: All applicable mechanical controls are to be constructed as the first item of work. Following their completion, rough grade, finish grade, and install appropriate erosion and sedimentation aids. Before newly constructed stormwater conveyance channels or pipes are made operational, adequate outlet protection and any required temporary or permanent channel lining shall be installed in both the conveyance channel and receiving channel (4VAC50-30-40 Minimum Standard No. 11). Retain control devices until final stabilization of all areas or as directed by the County Representative. Sequence of Construction: CONSTRUCTION PHASES: a.First Phase: 1.Install Construction Entrance. 2.Install diversion dike, R/W diversion and silt fence as shown on plan 3.Install Inlet protection for existing culverts. 4.Construct sediment traps. 5.Install construction safety fence where appropriate. 6.Begin demolition and removal of existing paved surfaces. b.Second Phase: 1.Maintain all measures installed in First Phase 2.Install storm sewer. 3.Install inlet protection, outlet protection. 4.Upon construction of travelways, replace diversion dike with silt fence. c.Third Phase 1.Maintain all measures installed in First and Second Phases 2.Finish grade. 3.Stabilize as necessary. d.Fourth Phase: 1.Remove temporary sediment control measures on transition to site development per approved plan and construction bioretention facility. H.Maintenance Program: All control measures are to be inspected daily by the site superintendent or his representative. Any damaged structure should be repaired at the close of the day. Inlet protection devices and silt fencing should be cleaned at 50% capacity and spread on-site where practical. Control structures shall not be removed until all areas above have been finally stabilized and seeded areas established. No control shall be removed without the site inspector's prior approval. The daily control measure inspections by the contractor shall be documented to indicate findings and corrective action taken. These UHSRUWVVKDOOEHVXEPLWWHGWRWKH&LW\RQFHHYHU\WZRZHHN¶VEDVLV:KHUHVHGLPHQWLV transported onto a paved or public road surface, the road surface shall be cleaned thoroughly at the end of each day. Sediment shall be removed from the roads by shoveling or sweeping and transported to stockpile areas. Street washing shall be allowed only after sediment is removed in this manner. (4VAC50-30-40 Minimum Standard No. 17). Stormwater Management: The stormwater quantity is met by confirmation that the post development does not exceed pre-development for the 10-year storm. See the Stormwater Plan Narrative for supporting documentation. Water Quality: The stormwater quality is met by Level Two Bioretention filters. See the Stormwater Plan Narrative for supporting documentation. Compacted Soil TEMPORARY DIVERSION DIKE SOURCE: VA. DSWC 4.5' min. 18" min. Flow PLATE 3.09-1 FILTER CLOTH 70' MIN. STONE CONSTRUCTION ENTRANCE SIDE ELEVATION (WITH WIRE SUPPORT) CONSTRUCTION OF A SILT FENCE FLOW FLOW NOTES: 1. APRON LINING MAY BE RIPRAP, GROUTED RIPRAP, GABION 2. La IS THE LENGTH OF THE RIPRAP APRON AS CALCULATED 3. d = 1.5 TIMES THE MAXIMUM STONE DIAMETER, BUT NOT PIPE OUTLET CONDITIONS KEY IN 6"-9"; RECOMMENDED FOR ENTIRE PERIMETER KEY IN 6"-9"; RECOMMENDED FOR ENTIRE PERIMETERSECTION A-A PLAN VIEW SECTION A-A BASKET, OR CONCRETE. USING PLATES 3.18-3 AND 3.18-4. LESS THAN 6 INCHES. Source: Va. DSWC d o A FILTER CLOTH FILTER CLOTH L a PLAN VIEW A od o3d 0 % Plate 3.18-1 PIPE OUTLET TO WELL 0 % d DEFINED CHANNEL A (MIN.)o3d AREA WITH NO DEFINED A CHANNEL PIPE OUTLET TO FLAT L a d WASHRACK (OPTIONAL) POSITIVE DRAINAGE TO SEDIMENT TRAPPING DEVICE VDOT #1 COURSE AGGREGATE FILTER CLOTH REINFORCED CONCRETE 12' MIN. EXISTING GROUND B DRAIN SPACE MIN.10' 10' MIN. EXISTING PAVEMENT 10' MIN. SECTION B-B SECTION A-A PLAN VIEW B TEMPORARY SEDIMENT TRAP CROSS SECTION OF OUTLET OUTLET (PERSPECTIVE VIEW) SOURCE: VA. DSWC PLATE. 3.13-2 **COARSE AGGREGATE SHALL BE VDOT #3, #357 OR #5 ROCK CHECK DAM 2 ACRES OR LESS OF DRAINAGE AREA: 2-10 ACRES OF DRAINAGE AREA: (DOWNSTREAM VIEW) (DOWNSTREAM VIEW) FILTER CLOTH (OPTIONAL) COARSE AGGREGATE VDOT #1 SOURCE: VA. DSWC FLOW 6" FILTER CLOTH (OPTIONAL) COARSE AGGREGATE VDOT #1 FLOW 6" PLATE. 3.20-1 CLASS I RIPRAP 2: 1 3' 3' 2: 1 3' 3' SILT FENCE CULVERT INLET PROTECTION OPTIONAL STONE COMBINATION* PLATE. 3.08-1 Shenandoah University Parking Structure Frederick County Erosion and Sediment Control Narrative and Stormwater Management Plan Project Description The purpose of this project is the construction of a multi-level parking garage and respective walkways and utilities. It will require the removal of an athletic field. The site is located in the northeastern area of the University campus, just north of Ralph Shockey Drive. Interstate 81 lies to the west of the site. A site map is included on the plans. About 4.00 acres will be disturbed during construction of the project. Existing Site Conditions The site of the proposed construction currently has an athletic field, access drive and pavillion. The topography varies greatly on the site. Slopes on the site range from 2.0 in the athletic field area to 66.0% in the adjacent ravine area. The site is partially wooded. The 100-year floodplain does exist on the southern portion of the site towards Abrams Creek. Adjacent Areas The site is located entirely on the property of Shenandoah University. I-81 lies to the west of the property. Winchester golf club is to the east, and Ralph Shockey Drive and Abrams Creek are to the south. Offsite Areas No offsite areas will be disturbed during construction. Soils According to the USDA Web Soil Survey the soils within the limits of disturbance are 29 Massanetta Loam and Weikert-Berks Channery Silt Loam. Massanetta Loam is in the hydrologic soil group C and no slope description is given for this soil. Weikert -Berks Channery Silt Loam is in the hydrologic soil group D with slopes of 25 to 65 percent. Erosion and Sediment Control Measures 1.0 General 1.1 Description: A.Work Included: Erosion and sediment control operations and devices required for this work are indicated on the drawings and include but are not necessarily limited to: 1. Installation of temporary control devices; 2. Maintenance of temporary control devices; 3. Temporary forms of stabilization; 4. Installation of permanent control devices; 5. Removal of devices and site restoration. 1.2 Standards: A.The following codes and standards, latest editions form a part of this specification, to the extent of all provisions applicable to the work required for this project, and as specifically referenced herein. 1. All work shall comply with the Virginia Erosion and Sediment Control Handbook and as amended by local codes and regulations. 2. VDOT Specifications and Standards. 3.City of Winchester Specifications and Standards. 1.3 Protection: A. Use all means necessary to protect all materials incorporated into the work of this section before, during and after installation. In the event of damage, immediately make all repairs and replacements necessary to the approval of the Owner's Representatives and at no additional cost to the Owner. B. Maintain and protect all benchmarks, monuments and similar reference points and, if they are displaced or destroyed by these operations, replace same as directed at no additional cost to the Owner. 1.4 Permits: A.The Contractor will secure certificates and permits and pay for all fees required by local codes and regulations. The Contractor shall ensure that value of the erosion and sediment control work to include maintenance and all seeding of disturbed areas shall be included in the overall project performance bond. 2.0 Execution 2.1 General Requirements: A. Limit grading to only those areas involved in current construction activities. Limit length of time for exposure of unprotected graded areas. Permanent stabilization of graded areas shall be done within seven days after construction. If permanent stabilization cannot be provided, temporary seeding, mulching or other forms of stabilization shall be provided. B. The construction entrance, construction safety fence (if required), diversion, silt fence, inlet protection, and sediment traps shall be constructed as part of the initial phase of construction and shall be made functional as soon as possible. These improvements are shown on the Erosion and Sediment Control Plan. Other sedimentation control devices, silt fence and inlet/outlet protection, will be installed as construction progresses. Construction of the devices shall agree with the details shown on the plan subject to modifications thereof that the City Inspector deems advisable. Regardless, the sediment control devices shall comply with all requirements of the Virginia Erosion and Sediment Control Handbook. They shall remain in place until all surfaces within the project are stabilized such that siltation will not occur; i.e., all upstream areas from the control devices have vegetation established, mulch in place or furnished pavement completed. All temporary erosion and sediment control measures shall be removed within 30 days after final site stabilization or after the temporary measures are no longer needed, unless otherwise authorized by the local program authority. Trapped sediment and the disturbed soil areas resulting from the disposition of temporary measures shall be removed off site or permanently stabilized to prevent further erosion and sedimentation (4VAC50-30-40 Minimum Standard No. 18). C. The Contractor agrees to hold the Owner or any of its agents harmless from any and all liability or damage that may arise from a violation of the siltation ordinance and agrees to indemnify them against any loss. D.Storm and Utility lines shall be installed in accordance with the following standards in addition to other applicable criteria (4VAC50-30-40 Minimum Standard No. 16): 1.No more than 500 linear feet of trench may be opened at one time. 2.Excavated material shall be placed on the uphill side of trenches. 3.Effluent from dewatering operations shall be filtered or passed through an approved sediment trapping device, or both, and discharged in a manner that does not adversely affect flowing streams or off-site property. 4.Restabilization shall be accomplished in accordance with these regulations. 5.Applicable safety regulations shall be complied with. E. Soil Stabilization: Permanent or temporary soil stabilization shall be applied to denuded areas within seven days after final grade is reached on any portion of the site. Temporary soil stabilization shall be applied within seven days to denuded areas that may not be at final grade but will remain dormant (undisturbed) for longer than 30 days. Permanent stabilization shall be applied to areas that are to be left dormant for more than one year (4VAC50-30-40 Minimum Standard No. 1). During construction of the project, soil stockpiles and borrow areas shall be stabilized or protected with sediment trapping devices (i.e., silt fence). Contractor is responsible for the temporary protection and permanent stabilization of all soil stockpiles on site as well as borrow areas and soil intentionally transported from the project site (4VAC50-30-40 Minimum Standard No. 2). Stabilization measures shall be applied to earthen structures such as dams, dikes, and diversions immediately after installation (4VAC50-30-40 Minimum Standard No. 5). PROTECTION SILT FENCE DROP INLETSILT FENCE DROP INLET PROTECTION PERSPECTIVE VIEWSPERSPECTIVE VIEWS INLET DRAINS A RELATIVELY FLAT AREA (SLOPE NO GREATER APPLY TO INLETS RECEIVING CONCENTRATED FLOWS, SUCH AS EXCEEDING 1 C.F.S.) ARE TYPICAL. THE METHOD SHALL NOT THAN 5%) WHERE THE INLET SHEET OR OVERLAND FLOWS (NOT THIS METHOD OF INLET PROTECTION IS APPLICABLE WHERE THE INLET DRAINS A RELATIVELY FLAT AREA (SLOPE NO GREATER APPLY TO INLETS RECEIVING CONCENTRATED FLOWS, SUCH AS EXCEEDING 1 C.F.S.) ARE TYPICAL. THE METHOD SHALL NOT THAN 5%) WHERE THE INLET SHEET OR OVERLAND FLOWS (NOT THIS METHOD OF INLET PROTECTION IS APPLICABLE WHERE THE SPECIFIC APPLICATIONSPECIFIC APPLICATION ELEVATION OF STAKE ANDELEVATION OF STAKE AND FABRIC ORIENTATIONFABRIC ORIENTATION IN STREET OR HIGHWAY MEDIANS.IN STREET OR HIGHWAY MEDIANS. FABRICFABRIC 11 AA STAKESTAKE 2 X 4" WOOD FRAME 1.5' MAX.1.5' MAX. 3' MIN.3' MIN. PLATE 3.07-1 DETAIL ADETAIL A 1' MIN.1' MIN. AT CORNERSAT CORNERS WITH GRATEWITH GRATE DROP INLETDROP INLET GATHER EXCESS GATHER EXCESS FRAMEFRAME INTE R S T A T E 8 1 RA L P H S H O C K E Y D R I V E 10 0 Y E A R F L O O D P L A I N AB R A M S C R E E K 29 1C 41E 41E 41E 29 41E PRE-DEVELOPMENT CDA: ON-SITE LOD AREA: 4.0 ACRES FOREST: 0.46 ACRES MANAGED TURF: 3.22 ACRES IMPERVIOUS: 0.32 ACRES ORIGINAL CN: 81 ON-SITE POST-DEV. WQ. CDA: B 1.22 ACRES CN: 92 ON-SITE POST-DEV. WQ CDA: D 0.11 ACRES CN: 77 POST DEVELOPMENT CDA: ON-SITE LOD LIMITS OF DISTURBANCE LIMITS OF DISTURBANCE 2 0 . 5 9 ' E M 670 674 672 674 64 8 646 6 5 0 652 676 6 4 4 64 6 668 x672.5 x 672.5 0.9 5 % 672 672 671 NOT FOR CONSTRUCTION CS9201 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y ON - S I T E P R E A N D P O S T D E V E L O P M E N T DR A I N A G E A R E A M A P HOSH1701 1"=40' JDS MMA SHEET OF16 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 40'80' NORTH                             SYMBOL 1B Berks Channery Silt Loam, 3 to 8 Percent slopes DESCRIPTION 1C Berks Channery Silt Loam, 8 to 15 Percent slopes 29 Massanetta Loam 41D Weikert-Berks Channery Silt Loams, 15 to 25 Percent Slopes 41E Weikert-Berks Channery Silt Loams, 25 to 65 Percent Slopes SOIL TYPES 1C 1C 41E 41E 41E 29 41E 10 0 Y E A R F L O O D P L A I N AB R A M S C R E E K E 670 674 672 674 64 8 646 6 5 0 652 676 6 4 4 64 6 668 672 671 POST-DEVELOPMENT CDA: ON-SITE OFF-SITE ANALYSIS AREA: 5.77 ACRES PRE-DEVELOPMENT CDA: TOTAL DRAINAGE AREA ON-SITE & OFF-SITE ANALYSIS AREA: 5.77 ACRES FOREST: 1.29 ACRES MANAGED TURF: 4.16 ACRES IMPERVIOUS: 0.32 ACRES ORIGINAL CN: 76 LIMITS OF DISTURBANCE LIMITS OF DISTURBANCE NOT FOR CONSTRUCTION CS9401 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y ON - S I T E O F F - S I T E P O S T D E V E L O P M E N T DR A I N A G E A N A L Y S I S HOSH1701 1"=40' JDS MMA SHEET OF17 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 40'80' NORTH                             SYMBOL 1B Berks Channery Silt Loam, 3 to 8 Percent slopes DESCRIPTION 1C Berks Channery Silt Loam, 8 to 15 Percent slopes 29 Massanetta Loam 41D Weikert-Berks Channery Silt Loams, 15 to 25 Percent Slopes 41E Weikert-Berks Channery Silt Loams, 25 to 65 Percent Slopes SOIL TYPES STUDY POINT TOTAL STUDY POINT ANALYSIS WATERSHED AREA = 22.08 AC. 1B 1C 29 41D 41E 1C 1C 41E 41E 41E 29 1C 41E 41E 41E 41E 1C 1C 41E 41E 1B 1B NOT FOR CONSTRUCTION CS9501 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y ST U D Y P O I N T W A T E R S H E D HOSH1701 1"= 80' JDS MMA SHEET OF18 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 80'160' NORTH                             SYMBOL 1B Berks Channery Silt Loam, 3 to 8 Percent slopes DESCRIPTION 1C Berks Channery Silt Loam, 8 to 15 Percent slopes 29 Massanetta Loam 41D Weikert-Berks Channery Silt Loams, 15 to 25 Percent Slopes 41E Weikert-Berks Channery Silt Loams, 25 to 65 Percent Slopes SOIL TYPES NOT FOR CONSTRUCTION CS9001 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y HOSH1701 1"= 20' JDS MMA SHEET OF19 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 20'40' NORTH                             BI O R E T E N T I O N P L A N BIORETENTION BASIN PLAN BASIN A SCALE: 1" = 20' BIORETENTION BASIN PLAN BASIN B SCALE: 1" = 20' LEVEL 2 BIORETENTION TOP 3" MULCH=668.25 TOP 3' SOIL MEDIA=668.00 TOP 3" PEA GRAVEL=665.00 TOP 12" GRAVEL SUMP=664.75 BOTTOM 12" GRAVEL SUMP=663.75 INV. 6" UNDER DRAIN @ UPPER END=664.33 INV. 6" UNDER DRAIN @ LOWER END=664.25 INV. OUT OF 6" OUTFALL PIPE = 663.93 CLEANOUT ELEV.=668.75 WIDTH OF SPILLWAY=11' TOP OF SPILLWAY = 669.50 LEVEL 2 BIORETENTION TOP 3" MULCH=652.25 TOP 3' SOIL MEDIA=652.00 TOP 3" PEA GRAVEL=649.00 TOP 12" GRAVEL SUMP=648.75 BOTTOM 12" GRAVEL SUMP=647.75 INV. 6" UNDER DRAIN @ UPPER END=648.31 INV. 6" UNDER DRAIN @ LOWER END=648.25 INV. OUT OF 6" OUTFALL PIPE = 647.75 CLEANOUT ELEV.=652.75 WIDTH OF SPILLWAY=11' TOP OF SPILLWAY = 654.00 BIORETENTION BASIN PLAN BASIN E SCALE: 1" = 20' LEVEL 2 BIORETENTION TOP 3" MULCH=668.25 TOP 3' SOIL MEDIA=668.00 TOP 3" PEA GRAVEL=665.00 TOP 12" GRAVEL SUMP=664.75 BOTTOM 12" GRAVEL SUMP=663.75 INV. 6" UNDER DRAIN @ UPPER END=664.33 INV. 6" UNDER DRAIN @ LOWER END=664.25 INV. OUT OF 6" OUTFALL PIPE = 664.15 CLEANOUT ELEV.=668.75 NOT FOR CONSTRUCTION CS9002 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y HOSH1701 NO SCALE JDS MMA SHEET OF20 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K                             BI O R E T E N T I O N D E T A I L S BIORETENTION AREA OBSERVATION WELL PROVIDE BASE PLATE GRAVEL SUMP 6" PVC SCHED. 40 PERFORATED PIPE 3" MULCH LAYER PROVIDE CAP 6" NOT TO SCALE ´ ´´ ³ ´ NOT FOR CONSTRUCTION CS9003 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y HOSH1701 AS SHOWN JDS MMA SHEET OF21 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K                             BI O R E T E N T I O N C A L C U L A T I O N S NOT FOR CONSTRUCTION CS1001-LITE BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y HOSH1701 1"= 30' JDS MMA SHEET OF22 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 30'60' NORTH                             LI G H T I N G P L A N PROPOSED LIGHTING FIXTURE NOTE: PROVIDE MIN. 3' SEPARATION FROM LIGHT POLE BASE TO FACE OF CURB OR TRAVELWAYS.Lighting Notes: 1.All lighting will conform to the Zoning Ordinance Section 165-201.07 requirements. 2.The height of all pole-mounted fixtures (including base) shall not exceed 25 feet as allowed under the Zoning Ordinance. 3.Light fixtures shall be placed outside of the paved areas of a site either within landscaped islands or in the perimeter green space of the site. 4.Building-mounted or wall-pack lighting fixtures shall not be mounted more than 25 feet above the finished grade of the building. 24" SWSC 50'R. 50'R. 5 0 ' R . 12" STORM PIPE (WITH PARKING GARAGE)12" STORM PIPE E PROPOSED ELECTRIC SERVICE ELECTRIC SERVICE TO BE EXTENDED FROM EXISTING SERVICE AT FOOTBALL STADIUM. 20 FT. WATER EASEMENT PROPOSED BIORETENTION BASIN B PROPOSED BIORETENTION BASIN A M 20 FT. WATER EASEMENT INT E R S T A T E 8 1 RA L P H S H O C K E Y D R I V E EX I S T I N G F L O O D W A Y EX I S T I N G F L O O D W A Y EXISTING WATERLINE AB R A M S C R E E K 50' B R L 35 ' B R L 25' BRL FIRE LANE SIGN TYPE "A" FIRE LANE SIGN TYPE "B" FIRE LANE SIGN TYPE "B" FIRE LANE SIGN TYPE "A" FIRE LANE SIGN TYPE "C" FIRE LANE SIGN TYPE "A" FIRE LANE SIGN TYPE "C"FIRE LANE SIGNS TYPE "D" FIRE LANE SIGNS TYPE "D" FIRE LANE SIGNS TYPE "D" FIRE DEPT. CONNECTION FIRE HYDRANT FIRE HYDRANT FIRE LANE MARKING FIRE LANE MARKING FIRE LANE MARKING FIRE LANE SIGN TYPE "C" FIRE LANE SIGNS TYPE "D" FIRE LANE SIGNS TYPE "D" FIRE HYDRANT FIRE LANE SIGN TYPE "A" FIRE LANE SIGN TYPE "C" 6" YELLOW STRIPE FOR FIRE LANE 6" YELLOW STRIPE FOR FIRE LANE FIRE LANE SIGN TYPE "D" (BUILDING MOUNTED) NOT FOR CONSTRUCTION CS1001-FIRE BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y FI R E L A N E A N D S I G N A G E P L A N HOSH1701 1"=30' JDS MMA SHEET OF23 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 30'60' NORTH                             PE N N O N I A S S O C I A T E S I N C . NOT FOR CONSTRUCTION CS1002-FIRE BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y FI R E L A N E D E T A I L S HOSH1701 NO SCALE JDS MMA SHEET OF24 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K                             PE N N O N I A S S O C I A T E S I N C . INT E R S T A T E 8 1 RA L P H S H O C K E Y D R I V E EX I S T I N G F L O O D W A Y 10 0 Y E A R F L O O D P L A I N EX I S T I N G F L O O D W A Y EXISTING WATERLINE AB R A M S C R E E K 50' B R L 35 ' B R L 25' BRL E M 670 674 672 674 64 8 646 6 5 0 652 676 6 4 4 64 6 668 x672.5 x 672.5 672 671 0+0 0 1 + 0 0 2+ 0 0 3+00 4+00 5+00 5 + 8 1 2 0 . 5 9 ' NOT FOR CONSTRUCTION CS2001 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y LA N D S C A P E P L A N HOSH1701 1"=30' JDS MMA SHEET OF25 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K 00 30'60' NORTH                             LEGEND NOT FOR CONSTRUCTION CS2002 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y LA N D S C A P E D E T A I L S HOSH1701 NO SCALE JDS MMA SHEET OF26 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K                             SHRUB PLANTING TREE PLANTING "D" "D" "D" OR PERENNIAL PLANTING DETAIL GROUNDCOVER, ORNAMENTAL GRASS TYPICAL MULCH EDGING DETAIL GENERAL CONDITIONS: MAINTENANCE OF LANDSCAPING NOTES: PARKING LOT LANDSCAPE CALCULATIONS:GENERAL PLANT LIST BIORETENTION PLANTING CALCULATIONS: EVERGREEN TREE PLANTING BIORETENTION / BIO-SWALE PLANT LIST FREDERICK COUNTY REQUIREMENTS: NOT FOR CONSTRUCTION CS6001 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y SI T E D E T A I L S HOSH1701 NO SCALE JDS MMA SHEET OF27 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K                             Maximum cross slope of a walking surface is 1:48, per ANSI A117.1 Section 403.3. NOT FOR CONSTRUCTION CS6002 BY NO . DA T E RE V I S I O N S SH E N A N D O A H U N I V E R S I T Y P A R K I N G S T R U C T U R E SP # 3 7 - 1 7 10 2 5 R A L P H S H O C K E Y D R I V E WI N C H E S T E R , V I R G I N I A 14 6 0 U N I V E R S I T Y D R I V E WI N C H E S T E R , V I R G I N I A 2 2 6 0 1 SH E N A N D O A H U N I V E R S I T Y SI T E D E T A I L S HOSH1701 NO SCALE JDS MMA SHEET OF28 28 ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION OR ADAPTATION BY PENNONI ASSOCIATES FOR THE SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO PENNONI ASSOCIATES; AND OWNER SHALL INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR RESULTING THEREFROM. AL L D I M E N S I O N S M U S T B E V E R I F I E D B Y C O N T R A C T O R AN D O W N E R M U S T B E N O T I F I E D O F A N Y DI S C R E P A N C I E S B E F O R E P R O C E E D I N G W I T H W O R K                             4" 21A 1/4" DIAMOND PLATE ALUMINUM 32" WIDE SECTION THRU CONCRETE FLUME 24"6"6" 6" LENGTH AS REQUIRED 7" 2'-0"6" 13 " 4" 6" 1":1' CG-6R - REVERSE GUTTER NOT TO SCALE STOP SIGN - DETAIL