Loading...
HomeMy WebLinkAbout04-06 Design Plancin Lilar X g WIRELESS SITE NAME: RIDINGS HILL SITE ADDRESS: 1009 GERMANY ROAD STEPHENS CITY, VA 22655 SITE NUMBER: 1724 NEW EQUIPMENT AND ANTENNAS ON A NEW 150' MONOPOLE TOWER ENGINEER DYNATEK DEVELOPMENT SERVICES INC. 435 CRESTVIEW DRIVE TRANSFER, PA 16154 PHONE 800-838-3224 FAX 724-646-1384 CONTACT: JASON E. DOCTER PARCEL INFORMATION JURISDICTION: FREDERICK COUNTY ZONED: RA PROPERTY INFO: BOOK 814, PAGE 1232, PROPERTY OWNER: OWNER: PAUL G. ANDERSON JR. ADDRESS: 1009 GERMANY ROAD, STEPHENS CITY, VA 22655 CONTACT: PAUL ANDERSON I PROJECT INFORMATION I SITE NAME: RIDINGS HILL SITE NUMBER: 1724 SITE ADDRESS: 1009 GERMANY ROAD STEPHENS CITY, VA 22655 ZONED: RA LAT.:39'05'53.94" N LON.: 78'15'42.58" W GROUND ELEV.: ±919.1' LANDLORD: PAUL G. ANDERSON JR. 1009 GERMANY ROAD STEPHENS CITY, VA 22655 CONTACT: PAUL ANDERSON APPLICANT: CINGULAR WIRELESS 7150 STANDARD DRIVE HANOVER, MD 21076 OFFICE: 410-712-7700 FAX: 410-712-7827 A.D.A. COMPLIANCE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION THIS FACILITY SHALL MEET OR EXCEED ALL FAA AND FCC REGULATORY REQUIREMENTS PROJECT SUMMARY THE FOLLOWING PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS AND AUTHORIZE THE CONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HERIN. ALL DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT AND MAY IMPOSE CHANGES OR MODIFICATIONS. CINGULAR CONST.: _.. PRINT: DATE CINGULAR R.F.: PRINT: DATE CINGULAR OPER.: PRINT: DATE PROJECT MANAGER: PRINT: DATE PROPERTY OWNER.: PRINT: DATE -- APPROVALS REV' NO. DATE I DESCRIPTION 0 10/13/04 90% 1 11/19/04 95% 2 1/20/05 90% 3 2/10/05 95% 4 5/19/05 90% 5 5/23/05 95% fa r= old _ :FL;dr+4.P I.it::h Sugarland 1$u r_icrAMvwry fl:l=e: l7CT I', Upr'n- IIIc r;Tf Front Royal � van �J parva 'hn �lalr_ GiaanliUy Ctteirioilie T �. E-4 GROUNDING AND ELECTRICAL DETAILS 0 c 'h•y�T iti Fit'•:!: R. I-orav D'41? ,:3 IJ rly �•- Ft -1 J SHEET INDEX 0j'1jdd,,y CillillTf?TI:B f;f1..% ❑ d +. T-1 ❑ ❑ Na4er,tov'`rt� F"r Hr i .e - NhlAarsvr j}`p ser ARCHITECTURAL SITE PLAN A-2 TOWER ELEVATION & ANTENNA DETAILS A-3 $runswt¢l, A-4 R5 = GIlaf9C�T4':JIi - :.�r Iz'.ns GI.D`1r'•`' 1 I �`: i:.�;ae±�riv, ille - Ync7r.41:BFc fa r= old _ :FL;dr+4.P I.it::h Sugarland 1$u r_icrAMvwry fl:l=e: l7CT I', Upr'n- IIIc r;Tf Front Royal � van �J parva 'hn �lalr_ GiaanliUy Ctteirioilie T �. E-4 GROUNDING AND ELECTRICAL DETAILS 0 c 'h•y�T iti Fit'•:!: R. I-orav D'41? ,:3 IJ rly �•- Ft -1 J a DRIVING DIRECTIONS FROM HANOV R /GREEN 8 ELT: FROM STANDARD DR. START W ON RAMP TO SR 100, DORSEY RD, TURN RIGHT ONTO SR 100 AND PROCEED NW ONTO SR 103 PARK CIRCLE DR. TURN LEFT ONTO SR 103 PROCEED W TO LEFT TURN ONTO US1 WASHINGTON BLVD, TURN RIGHT ONTO 1-95 N THEN TO 1-70W AND BEAR RIGHT TO US 40 UNTIL YOU REACH US15. TURN LEFT ONTO US15 AND GO STRAIGHT TO SR15 W AND CONTINUE ON CR51 TO CR26 AND TURN LEFT ONTO UA 11. PROCEED STRAIGHT TO SR37, BEARING RIGHT ON SR37 TO US522 AND BEAR RIGHT ONTO SR37 W FOR 14.3 MILES. TURN RIGHT ONTO 1-81 S. BEAR RIGHT AND PROCEED TO SR277 THEN TO SR631. TURN RIGHT AND PROCEED STRAIGHT UP GERMANY RD TO TOP OF HILL WITH FARM ON RIGHT WITH ADDRESS 1009. PROCEED PAST FARM HOUSE W/PEACOCKS APPROX. 2/10 MILES TO CATTLE GATE ON RIGHT. VICINITY MAP SHT. NO. DESCRIPTION T-1 TITLE SHEET C-1 SURVEY A-1 ARCHITECTURAL SITE PLAN A-2 TOWER ELEVATION & ANTENNA DETAILS A-3 CONSTRUCTION DETAILS A-4 FENCE DETAILS S-1 SHELTER DETAILS E-1 GROUNDING PLAN & DETAILS E-2 GROUNDING AND ELECTRICAL DETAILS E-3 GROUNDING AND ELECTRICAL DETAILS E-4 GROUNDING AND ELECTRICAL DETAILS SHEET INDEX Xcingular WIRELESS W r�. yu21..�.. IS 10 nfkh, lPandayEd— s. R11w,,, VA 20190 US.I rDynatek] TELECOMMUNICATIONS SERVICES 435 Crestview Drive Transfer, PA 16154 Phone: 800-838-3224 Fax 724-646-1384 w_dynatekteI-o—. ' DYNATEK 4883 PROD. NO DRAWN BY. J. E.D_ CHECKEDBY: D.CB_ 01 SUBMITTALS 5 6/23/05 95% 4 5/19/05 90% 3 1/10/05 95% 2 1/20/05 90% 1 11/19/04 95% 0 10/13/04 90% THIS DOCUMENT IS THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED WORK OF CINGULARWIRELESS. ANY DUPLICATION OR USE WITHOUT EXPRESS WRITTEN CONSENT IS STRICTLY PROHIBITED. DUPLICATION AND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR LAWFULLY AUTHORIZED REGULATORY AND ADMINISTRATIVE FUNCTIONS IS SPECIFICALLY ALLOWED. RIDINGS HILI., #1724 1009 GERMANY ROAD STEPHENS CITY, VA 22655 TITLE SHEET PROJEC"I': SHEP;I': 1724 DA'L'E: 10/13/04 T— 1 scALl;.: NO SCALE Existing Power Pole POS�� F /W / \\\\Jr a^i//^ \� ''ry\ / Existing Power Pole / \ POST \ 1 I \ J $ ! N7sV1� S ST30�10E \ < \ FENCE TO BE EXTENDED 1453 TO IXISTING FENCE LINE\q�.,p�yW ,F \ S 7110.04'E / /I / ' I \ a \ps\ \\ HS7.65• �' + \ S ST50.4Y'E S / / I PAUL G. ANDERSOM, Jr. 100.00' \P / I / S 32'09•11111 Dg 814, Poge 1232 + \ 75.00• � POST PROPOSED 16' INORESS/EORESS h lrt1LTTY EASELIENT (2.685 S.F.) PROPOSED 75 X 75 LEASE AREA N 5730.49-W \PS (5625 S.F.) 7LOW PROPOSED 150' MONOPOLE/ OVERALL SITE PLAN 40 0 40 80 120 SCALE IN FEET LEGEND UTILITY POLE OVERHEAD UTILITY FLAGGED POST FOUND IRON PIN SET PROPOSED LEASE LINE — PROPERTY LINE CENTERLINE — CONTOUR LINE ----- V 37B 3 91A1 1T 35 36 37C 28 27 14 36A 37D 4 7 26 6 92 24 23 6 294 25 22 1 34 5 30 20 21 3413 37 93 5 p 31 O 0 19 34C 94 rn 29 95 17 Rt, 62 OP� 6 o PROPOSED 97 a 29A 28 SITE E 30'O' D 99 C 27 F g 00 26 a 99A ^� G 4 a 100 LINE � vNE H A 30A 300 25 15'(Ft Meabaro Roca ZR1Cj OVERALL PROPERTY AND SITE PLAN NOT TO SCALE PROPOSED INGRESS/EGRESS k UTILITY EASEMENT DESCRIPTION THE PROPOSED LEASE AREA SHALL BE CONNECTED TO GERMANY ROAD BY AN INGRESS/EGRESS & UTIUTY EASEMENT, SAID EASEMENT SHALL BE A UNIFORM WIDTH OF 16 feet AND SHALL LIE ALONG THE FOLLOWING CENTERLINE DESCRIPTION, BEGINNING AT A POINT ON THE CENTERLINE OF GERMANY ROAD, SAID POINT BEING LOCATED S 24' 17' 15" W. A DISTANCE OF 203.96 feet FROM A FLAGGED FENCE POST MARKING THE NORTHWEST CORNER OF THE LANDS OF PAUL G. ANDERSON, Jr. ALONG GERMANY ROAD; THENCE S 71' 10' 04" E. 67.85 feet TO A POINT; THENCE S 5T 50' 49" E, 100.00 feet TO A POINT AND TERMINUS ON THE WESTERN ONE OF THE PROPOSED LEASE AREA. SAID POINT BEING LOCATED N 32' 09' 11" E, 10.00 feet FROM AN IRON PIN MARKING THE SOUTHWEST CORNER OF THE PROPOSED LEASE AREA. THE PROPOSED INGRESS/EGRESS & UTILITY EASEMENT INCLUDES 2,685 SQUARE FEET xsingular WIRELESS Wi,clrs.. Facliurs, 1„c. IN1e Al d—I Fa E,, D6, Suai 200 R ­ VA 20110 USA Dynatek TELECOMMUNICATIONS SERVICES 435 Crestview On - Transfer, PA 16154 Phone: 800-838-3224 Fax: 724-646-1384 www.dynatektelec NU, com DYNATEK PROJ N0 DRAWN BY. R.C.H. CHECKED BY. W.W.S. SUBMITTALS 5 6/23/05 1 957. 4 5/19/05 90% 3 )/10/05 95% 2 1/20/05 90% 1 11/19/04 95% 0 10/13/04 90% THIS DOCUMENT IS THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED WORK OF LINGULAR WIRELESS. ANY DUPLICATION OR USE WITHOUT EXPRESS WRITTEN CONSENT IS STRICTLY PROHIBITED. DUPLICATION AND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR LAWFU_LY AUTHORIZED REGULATORY AND ADMINTSTRA TIVE FUNCTIONS IS SPECIFICALLY ALLOWED, RIDINGS HILL SITE ID # 1724 RAW LAND 1009 GERMANY ROAD STEPHENS CITY, VA 22655 LEASE AREA TOPOGRAPHIC SURVEY PROJECT: SLICE'[': 1724 SCALE 10/20/04 llA'f'E: /� 10/20/04 c _ 1 4S SHOWN NOTES: PROPOSED LEASE AREA DESCRIPTION SITE DATA. BEGINNING AT AN IRON PIN SET MARKING THE NORTHWEST CORNER OF THE Ar 2. THE CONTOURS SHOWN ARE BASED ON NOVO 1929 DATUM. PROPOSED LEASE AREA, SAID IRON PIN BEING LOCATED S 25' 47' 58" E, 3. THIS DRAWING PREPARED BY WARREN WILLIAM SORG IS INTENDED TO SHOW THE LEASE AREA — r A DISTANCE OF 228.81 feet FROM A FLAGGED FENCE POST MARKING THE PARCEL No. 73—A-100 NORTHWEST CORNER OF THE LANDS OF PAUL G. ANDERSON, Jr. ALONG GERMANY 4. THE UNMONUMENTED PROPERTY POINTS AND OVERALL PROPERTY BOUNDARY SHOWN ON THIS DRAWING WERE REPRODUCED WITHOUT BENEFIT OF TITLE SEARCH DOCUMENTS. WARREN WILLIAM SORG CERTIFIES --- ROAD; THENCE S 5T 50' 49" E, 75.00 feet TO AN IRON PIN SET MARKING OWNER PAUL G. ANDERSON, Jr. THE SOUTHEAST CORNER OF THE PROPOSEDLEASE AREA; THENCE S 32' 09' 11" W, 75.00 feet TO AN IRON PIN MARKING THE SOUTHWEST DEED REFERENCE DB 819, Pa e 1232 9 CORNER OF THE PROPOSED LEASE AREA; THENCE N 5T 50' 49" W. 75.00 feet TO AN IRON PIN MARKING THE SOUTHWEST CORNER OF THE PROPOSED ZONING RA LEASE AREA; THENCE N 32' 09' 11" E, 75.00 feet TO AN IRON PIN, THE POINT AND PLACE OF BEGINNING. THE PROPOSED LEASE AREA INCLUDES 5,625 SQUARE FEET. PROPOSED INGRESS/EGRESS k UTILITY EASEMENT DESCRIPTION THE PROPOSED LEASE AREA SHALL BE CONNECTED TO GERMANY ROAD BY AN INGRESS/EGRESS & UTIUTY EASEMENT, SAID EASEMENT SHALL BE A UNIFORM WIDTH OF 16 feet AND SHALL LIE ALONG THE FOLLOWING CENTERLINE DESCRIPTION, BEGINNING AT A POINT ON THE CENTERLINE OF GERMANY ROAD, SAID POINT BEING LOCATED S 24' 17' 15" W. A DISTANCE OF 203.96 feet FROM A FLAGGED FENCE POST MARKING THE NORTHWEST CORNER OF THE LANDS OF PAUL G. ANDERSON, Jr. ALONG GERMANY ROAD; THENCE S 71' 10' 04" E. 67.85 feet TO A POINT; THENCE S 5T 50' 49" E, 100.00 feet TO A POINT AND TERMINUS ON THE WESTERN ONE OF THE PROPOSED LEASE AREA. SAID POINT BEING LOCATED N 32' 09' 11" E, 10.00 feet FROM AN IRON PIN MARKING THE SOUTHWEST CORNER OF THE PROPOSED LEASE AREA. THE PROPOSED INGRESS/EGRESS & UTILITY EASEMENT INCLUDES 2,685 SQUARE FEET xsingular WIRELESS Wi,clrs.. Facliurs, 1„c. IN1e Al d—I Fa E,, D6, Suai 200 R ­ VA 20110 USA Dynatek TELECOMMUNICATIONS SERVICES 435 Crestview On - Transfer, PA 16154 Phone: 800-838-3224 Fax: 724-646-1384 www.dynatektelec NU, com DYNATEK PROJ N0 DRAWN BY. R.C.H. CHECKED BY. W.W.S. SUBMITTALS 5 6/23/05 1 957. 4 5/19/05 90% 3 )/10/05 95% 2 1/20/05 90% 1 11/19/04 95% 0 10/13/04 90% THIS DOCUMENT IS THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED WORK OF LINGULAR WIRELESS. ANY DUPLICATION OR USE WITHOUT EXPRESS WRITTEN CONSENT IS STRICTLY PROHIBITED. DUPLICATION AND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR LAWFU_LY AUTHORIZED REGULATORY AND ADMINTSTRA TIVE FUNCTIONS IS SPECIFICALLY ALLOWED, RIDINGS HILL SITE ID # 1724 RAW LAND 1009 GERMANY ROAD STEPHENS CITY, VA 22655 LEASE AREA TOPOGRAPHIC SURVEY PROJECT: SLICE'[': 1724 SCALE 10/20/04 llA'f'E: /� 10/20/04 c _ 1 4S SHOWN NOTES: 1. NO SUBSURFACE UTILITY LOCATIONS WERE DETERMINED BY WARREN WILLIAM SORG; AND THEREFORE, NO SUBSURFACE UTILITIES ARE SHOWN ON THIS DRAWING. Ar 2. THE CONTOURS SHOWN ARE BASED ON NOVO 1929 DATUM. 3. THIS DRAWING PREPARED BY WARREN WILLIAM SORG IS INTENDED TO SHOW THE LEASE AREA — r AND INGRESS /EGRESS AND UHLNY EASEMENT AREAS. NO ENGINEERING SERVICES RELATIVE TO THE PROPOSED POST TOWER AND/OR EQUIPMENT INSTALLATION WERE PROVIDED BY WARREN WILLIAM SORG GIPS 4. THE UNMONUMENTED PROPERTY POINTS AND OVERALL PROPERTY BOUNDARY SHOWN ON THIS DRAWING WERE REPRODUCED WITHOUT BENEFIT OF TITLE SEARCH DOCUMENTS. WARREN WILLIAM SORG CERTIFIES --- ONLY THE LEASE AREA AND THE INGRESS/EGRESS EASEMENT AREA AND TIE—IN TO THE INDICATED BOUNDARY _-- CORNER. A SURVEY OF THE OVERALL. PROPERTY WAS NOT PERFORMED BY WARREN WILLIAM SORG. PROPOSED INGRESS/EGRESS k UTILITY EASEMENT DESCRIPTION THE PROPOSED LEASE AREA SHALL BE CONNECTED TO GERMANY ROAD BY AN INGRESS/EGRESS & UTIUTY EASEMENT, SAID EASEMENT SHALL BE A UNIFORM WIDTH OF 16 feet AND SHALL LIE ALONG THE FOLLOWING CENTERLINE DESCRIPTION, BEGINNING AT A POINT ON THE CENTERLINE OF GERMANY ROAD, SAID POINT BEING LOCATED S 24' 17' 15" W. A DISTANCE OF 203.96 feet FROM A FLAGGED FENCE POST MARKING THE NORTHWEST CORNER OF THE LANDS OF PAUL G. ANDERSON, Jr. ALONG GERMANY ROAD; THENCE S 71' 10' 04" E. 67.85 feet TO A POINT; THENCE S 5T 50' 49" E, 100.00 feet TO A POINT AND TERMINUS ON THE WESTERN ONE OF THE PROPOSED LEASE AREA. SAID POINT BEING LOCATED N 32' 09' 11" E, 10.00 feet FROM AN IRON PIN MARKING THE SOUTHWEST CORNER OF THE PROPOSED LEASE AREA. THE PROPOSED INGRESS/EGRESS & UTILITY EASEMENT INCLUDES 2,685 SQUARE FEET xsingular WIRELESS Wi,clrs.. Facliurs, 1„c. IN1e Al d—I Fa E,, D6, Suai 200 R ­ VA 20110 USA Dynatek TELECOMMUNICATIONS SERVICES 435 Crestview On - Transfer, PA 16154 Phone: 800-838-3224 Fax: 724-646-1384 www.dynatektelec NU, com DYNATEK PROJ N0 DRAWN BY. R.C.H. CHECKED BY. W.W.S. SUBMITTALS 5 6/23/05 1 957. 4 5/19/05 90% 3 )/10/05 95% 2 1/20/05 90% 1 11/19/04 95% 0 10/13/04 90% THIS DOCUMENT IS THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED WORK OF LINGULAR WIRELESS. ANY DUPLICATION OR USE WITHOUT EXPRESS WRITTEN CONSENT IS STRICTLY PROHIBITED. DUPLICATION AND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR LAWFU_LY AUTHORIZED REGULATORY AND ADMINTSTRA TIVE FUNCTIONS IS SPECIFICALLY ALLOWED, RIDINGS HILL SITE ID # 1724 RAW LAND 1009 GERMANY ROAD STEPHENS CITY, VA 22655 LEASE AREA TOPOGRAPHIC SURVEY PROJECT: SLICE'[': 1724 SCALE 10/20/04 llA'f'E: /� 10/20/04 c _ 1 4S SHOWN x x x LANDLORDS WANTS 145' EXTRA FENCE TO CINTINUE TO THE EXISTING FENCE LINE TOWER TO BE 175' OFF EXISTING FENCE THAT WE RUN THE EXTRA FENCE TO ARCHITECTURAL SITE PLAN r -X X X x x PROPOSED CINGULAR SECTOR #2 AZIMUTH 120' W/ x (3) ANTENNAS PER SECTOR AND A 12' SEPARATION ON BOOM MOUNT PROPOSED 75'x75' r CHAIN-LINK FENCED IN COMPOUND N x x PROPOSED CINGULAR SECTOR #1 AZIMUTH 0' W/ (3) ANTENNAS PER SECTOR x AND A 12' SEPARATION I ON BOOM MOUNT :T 0 75 X X X X X PROPOSED CSC CABINET x x x 3'-2" PROPOSED CINGULAR GPS ANTENNA PROPOSED 150' MONOPOLE PROPOSED CINGULAR ICE BRIDGE 37'-6" PROPOSED CINGULAR SECTOR #3 AZIMUTH 240' W/ (3) ANTENNAS PER SECTOR AND A 12' SEPARATION ON BOOM MOUNT PROPOSED CINGULAR 11'-6"x20' SHELTER PROPOSED UTILITY RACK FUTURE EXTENSION 3' 5'—__ 5'--1 r------------- _ N 1 n PROPOSED 12' WIDE ACCESS ROAD W/ A 16' CATTLE GATE AT THE BEGINNING PROPOSED 12' GATE 2' 0 2' 4' B' SCALE: xcingular WIRE -LESS Z = i it J \Vud— F-ilifies,1— UW0 Mkh-I Faraday D— Suice �0 Resron, VA 20190 USA Dynatek I DYNATEK 4883 PROJ. NO.: DRAWN BY: I.E.D. CHECKEDBY: D.C.B. SUBMITTALS 5 6/23/05 95% 4 5/19/05 907. 3 1/10/05 95% 2 1/20/05 90% 1 11/19/04 95% --_ 0 10/13/04 90% THIS DOCUMENT IS THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED WORK OF CINGULAR WIRELESS. ANY DUPLICATION OR USE WITHOUT EXPRESS WRITTEN CONSENT IS STRICTLY PROHIBITED. DUPLICATION AND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR LAWFULLY AUTHORIZED REGULATORY AND ADMINISTRATIVE FUNCTIONS IS SPECIFICALLY ALLOWED. RIDINGS HILL #1724 1009 GERMANY ROAD STEPHENS CITY, VA 22655 ARCHITECTURAL SITE PLAN PROJECT: SHEET: 1724 DATE: A-1 10/13/04 SCALE: NO SCALE 0 W U) O 0- O Of 0- O Ln G 0 W Z O In z Z W I— Z Q Q J 0 _Z O 0 w O n O n 0 d- w Z O 1n Q Z Z W I-- Of — Of W Q O w L� TOWER ELEVATION PROPOSED 7' LIGHTNING ROD PROPOSED CINGULAR ANTENNA LOCATION @ 150' AGL SECTOR #1 AZIMUTH 0' SECTOR #2 AZIMUTH 120' SECTOR #3 AZIMUTH 240° W/ (3) ANTENNAS PER SECTOR AND 12' SEPERATION PROPOSED 150' MONOPOLE 8' 0 8' 16' 24' SCALE: PROPOSED 50'x50'x12' COMPOUND PROPOSED 10'x20' rCINGULAR SHELTER GRADE 12'-0" SEPARATION (TYP.) 6' TYP. Q 0 ya U / J W Q 'J PROPOSED FUTURE ANTENNA (TYP) PROPOSED ANTENNA (TYP OF 6) FUTURE ANTENNA (TYP OF 3) PROPOSED ANTENNA PLATFORM (MICROFLECT CAT# B1833 OR AN APPROVED EQUAL) ANTENNA PLATFORM DETAILS 1 2 1 COLOR CODING SCHEDULE I I TOP DOWNTILT BRACKET r PANEL ANTENNA MOUNTING POLE TMA BOTTOM DOWNTILT BRACKET NOTES 1. MOUNT ANTENNA IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDED PROCEDURE LGP214OX TMA -DD -1900 FB TOWER MOUNTED AMPLIFIER 2-625+ n I ® o® I 10.3" AP14/17-880/1940/088D/ADT/XXP 88' MULTIBAND DIRECTIONAL ANTENNA ANTENNA W/DOWNTILT ASSEMBLY 1 5 1 TMA DETAIL 1 4 1 ANTENNA DETAIL 1 3 1 04 PROPOSED FUTURE (SECTOR 1) ANTENNA (TYP) #1 TBD #2 TBD #3 TBD O — O O0' NORTH TRUE �0 L O MANUFACTURER �0 270 90' o #1 O � 0N E, A. 150' 180^ CoQ ^ry� FB moo FUTURE 150' FUTURE TBD 41 #3 AP14/17-880/1940/088D/ADT/XXP ,lo 200'± LGP214OX TMA -DD -1900 0 TBD ANTENNA ORIENTATIONS: 0': 120': 240' ANTENNA PLATFORM DETAILS 1 2 1 COLOR CODING SCHEDULE I I TOP DOWNTILT BRACKET r PANEL ANTENNA MOUNTING POLE TMA BOTTOM DOWNTILT BRACKET NOTES 1. MOUNT ANTENNA IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDED PROCEDURE LGP214OX TMA -DD -1900 FB TOWER MOUNTED AMPLIFIER 2-625+ n I ® o® I 10.3" AP14/17-880/1940/088D/ADT/XXP 88' MULTIBAND DIRECTIONAL ANTENNA ANTENNA W/DOWNTILT ASSEMBLY 1 5 1 TMA DETAIL 1 4 1 ANTENNA DETAIL 1 3 1 NOTE: CABLE LENGTH HAS IU.:" ADDED FOR CONIKACIUK AND JIIL CUNUIIIVN�,. # OF ANTENNAS PER SECTOR: 3 (INSTALL 2, RESERVE 1) WITH 4 (INSTALL 2, RESERVE 2) TOWER MOUNTED AMPLIFIERS PER SECTOR *INDI- NEW EQUIPMENT: YES EQUIPMENT SHELTER SIZE: 10'.x20' 7 1 CABLE SCHEDULE AND RF SYSTEM DESIGN PLAN 6 X* cingular WIRELESS w %Vi lens F-ifilin, tnc. 1 "0 Zwhad F—day Da— S„„� 200 -1-1- -I- USA �Dynatek] DYNATEK 4883 PROJ. NO.: DRAWN BY: J.E.D. CHECKED BY. D.CB. SUBMITTALS 5 6/23/05 959 4 5/19/05 909 3 1/10/05 959 2 1/20/05 909 1 11/19/04 959 0 10/13/04 909 THIS DOCUMENT 5 THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED WORK OF CINGUTAR WIRELESS. ANY DUPLICATION OR USE WITHOUT EXPRESS WRITTEN CONSENT IS STRICTLY PROHIBITED. DUPLICATION AND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR LAWFULLY AUTHORIZED REGULATORY AND ADMINISTRATIVE FUNCTIONS IS SPECIFICALLY ALLOWED. RIDINGS HILL #1724 1009 GERMANY ROAD STEPHENS CITY, VA 22655 TOWER ELEVATIONS & ANTENNA DETAILS PROJECT: SHEET: 1724 DATE: SCALE: 10/13/04 A-2 NO SCALE ANTENNA POSITION ANTENNA TYPE AND RAD CENTER OENTATION TMA TYPE MANUFACTURER o #1 AP14/17-8BO/1940/088D/ADT/XXP 150' LGP214OX TMA -DD -1900 FB #2* FUTURE 150' FUTURE TBD #3 AP14/17-880/1940/088D/ADT/XXP 150' 200'± LGP214OX TMA -DD -1900 FB TBD o #1 AP14/17-880/1940/088D/ADT/XXP 150' LGP214OX TMA -DD -1900 FB TBD v w #2* FUTURE 150' 1 5/8"* FUTURE TBD w #3 AP14/17-880/1940/088D/ADT/XXP 150' LCP214DX TMA -DD -1900 FB TBD #1 AP14/17-880/1940/088D/ADT/XXP 150' LGP214OX TMA -DD -1900 FB TBD 0 rpt #2* FUTURE 150' 1 5/8"* FUTURE TBD On #3 AP14/17-880/1940/088D/ADT/XXP 150' LGP214OX TMA -DD -1900 FB TBD NOTE: CABLE LENGTH HAS IU.:" ADDED FOR CONIKACIUK AND JIIL CUNUIIIVN�,. # OF ANTENNAS PER SECTOR: 3 (INSTALL 2, RESERVE 1) WITH 4 (INSTALL 2, RESERVE 2) TOWER MOUNTED AMPLIFIERS PER SECTOR *INDI- NEW EQUIPMENT: YES EQUIPMENT SHELTER SIZE: 10'.x20' 7 1 CABLE SCHEDULE AND RF SYSTEM DESIGN PLAN 6 X* cingular WIRELESS w %Vi lens F-ifilin, tnc. 1 "0 Zwhad F—day Da— S„„� 200 -1-1- -I- USA �Dynatek] DYNATEK 4883 PROJ. NO.: DRAWN BY: J.E.D. CHECKED BY. D.CB. SUBMITTALS 5 6/23/05 959 4 5/19/05 909 3 1/10/05 959 2 1/20/05 909 1 11/19/04 959 0 10/13/04 909 THIS DOCUMENT 5 THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED WORK OF CINGUTAR WIRELESS. ANY DUPLICATION OR USE WITHOUT EXPRESS WRITTEN CONSENT IS STRICTLY PROHIBITED. DUPLICATION AND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR LAWFULLY AUTHORIZED REGULATORY AND ADMINISTRATIVE FUNCTIONS IS SPECIFICALLY ALLOWED. RIDINGS HILL #1724 1009 GERMANY ROAD STEPHENS CITY, VA 22655 TOWER ELEVATIONS & ANTENNA DETAILS PROJECT: SHEET: 1724 DATE: SCALE: 10/13/04 A-2 NO SCALE 1 LL O U 2 Ld U) 3 ANTENNA POSITION CURRENT FUTURE n 3 2 TX/RX TX/RX TX/RX TBD TBD TBD TBD TBD TBD TBD TBD TBD VIEW FROM INSIDE OF EQUIPMENT SHELTER/ROOM COLOR CODING TO BE DETERMINED IN THE FIELD R = RED BR = BROWN B = BLUE G = GREEN Y = YELLOW 0 = ORANGE COLOR KEY WAVEGUIDE PORT - INSIDE VIEW FINISHED GRADE F 36- MIN .1 TRENCH METALLIC WARNING TAPE w Q ON N f \ p J `UNDISTURBED ¢w J 12" a I1OT w a 12" COMPACTED BACKFILL COMPACTED SAND GKFORM 24-12 a 4" TELEPHONE PVC CONDUIT 4" POWER PVC CONDUIT 4" GENERATOR PLUG 6" MIN. PVC CONDUIT TYP. NOTE TO CONTRACTOR: INSTALL PULL BOXES ON RUNS EXCEEDING (4) 90' BENDS PER NEC STANDARDS. CONDUIT SEPARATION TO BE VERIFIED WITH LOCAL UTILITY CO. CONTRACTOR TO INSTALL DB60 NYLON PULL STRING IN POWER AND TELCO CONDUITS. CONTRACTOR TO USE SCHEDULE 80 GALV. PIPE UNDER ALL TRAFFIC CONDITIONS CONDUIT TRENCH DETAIL GPS ANTENNA (PROVIDED BY CINGULAR INSTI BY CONTRAI COAX GROUND N 1 1/2" MOUNTING 1/2" COAX #6 AWG GROUND TO GROUND Tn rGn11A1T1 NOTES: 1. LOCATION OF ANTENNA MUST HAVE CLEAR VIEW OF SOUTHERN SKY AND CANNOT HAVE ANY BLOCKAGES EXCEEDING 25% OF THE SURFACE AREA OF THE HEMISPHERE AROUND GPS ANTENNA 2. ALL GPS ANTENNA LOCATIONS MUST BE ABLE TO RECEIVE CLEAR SIGNALS FROM A MINIMUM OF FOUR (4) SATELLITES. VERIFY WITH HANDHELD GPS BEFORE FINAL LOCATION OF GPS ANTENNA. 4 3 I GPS ANTENNA MOUNTING DETAIL MICROFLECT 1/2"0 BOLT B508 SLEEVE AND LOCKWASHER MICROFLECT B1117 CANOPY ANGLE HANGER BRACKET MICROFLE( 8130 3 ICEBRID( PIPE SUPPOI CONCRE FOUNDATI FINISH GRADE ICEBRIDGE SECTION FENCE NOTES 1. ALTERNATE FOOTINGS FOR ALL FENCE POSTS IN LEDGE: IF LEDGE IS ENCOUNTERED AT GRADE OR AT DEPTH SHALLOWER THAN 3'-6" CORE DRILL AN 8" DIA HOLE 18" INTO THE LEDGE. CENTER POST IN THE HOLE AND FILL WITH CONCRETE OR GROUT. IF LEDGE IS BELOW FINISH GRADE. COAT BACKFILLED SECTION OF POST WITH COAL TAR AND BACKFILL WITH WELL DRAINING GRAVEL 2. ATTACH GATE WITH 1-1/2 PAIR OF NON -LIFT-OFF TYPE, MALLEABLE IRON OR FORGING, PIN -TYPE HINGES. ASSEMBLIES SHALL AI.I.OW FOR 180' OF GATE TRAVEL HEAVY RF BILL OF MATERIAL FOR GPS ANTENNA 3 STRANDS OF 4 -POINT BARBED WIRE ITEM STOCK CODE DESCRIPTION QUANITY 1. GKFORM 24-12 GROUNDING KIT 2 2. LCF12-50J COAX CABLE 1/2- STANDARD FLEX 120' 3. NM—LCF12-070 N MALE CONNECTOR 4 4. NM—LCF12-070 N FEMALE CONNECTOR 1 5_ 981262-001 GROUND BAR 1 6. M SURGE ARRESTOR 1 3 I GPS ANTENNA MOUNTING DETAIL MICROFLECT 1/2"0 BOLT B508 SLEEVE AND LOCKWASHER MICROFLECT B1117 CANOPY ANGLE HANGER BRACKET MICROFLE( 8130 3 ICEBRID( PIPE SUPPOI CONCRE FOUNDATI FINISH GRADE ICEBRIDGE SECTION FENCE NOTES 1. ALTERNATE FOOTINGS FOR ALL FENCE POSTS IN LEDGE: IF LEDGE IS ENCOUNTERED AT GRADE OR AT DEPTH SHALLOWER THAN 3'-6" CORE DRILL AN 8" DIA HOLE 18" INTO THE LEDGE. CENTER POST IN THE HOLE AND FILL WITH CONCRETE OR GROUT. IF LEDGE IS BELOW FINISH GRADE. COAT BACKFILLED SECTION OF POST WITH COAL TAR AND BACKFILL WITH WELL DRAINING GRAVEL 2. ATTACH GATE WITH 1-1/2 PAIR OF NON -LIFT-OFF TYPE, MALLEABLE IRON OR FORGING, PIN -TYPE HINGES. ASSEMBLIES SHALL AI.I.OW FOR 180' OF GATE TRAVEL HEAVY PRESSED STEEL 3 STRANDS OF 4 -POINT BARBED WIRE BARBED WIRE OUTRIGGER ARM el SUBMITTALS 5 6/23/05 95% 4 5/19/05 90% 3 1/10/05 95% 1-1/4" GATE_ 2-1/2" GATE FRAME POST 2" X 2"-9 GA. FENCE FABRIC BRAIDED COPPER GROUND STRAP (SEE•, GROUNDING SPECS) 1/2" CROWN TOR DRAINAGE M 2 1 FENCE DETAIL 24" WIDE SELF—SUPPORTING ICE BRIDGE KIT WITH 2—LEVEL TRAPEZE AS MANUFACTURED BY MICROFLECT. 2x2x3/16" STEEL ANGLE 38" LONG. ATTACHED TO PIPE W/ 1/2" U—BOLTS COAX TO ANTENNAS (SEE PLAN FOR NUMBER & POSITION OF CABLES) FOR CONCRETE, SEE NOTE 5� BASEPLATE 1/4" RADIUS FILLET WELD ALL THE WAY AROUND POST (NO FIELD WELDS) —( GATE OPN'G. VARIES It (10'-O" MAX.) \-1-1/4" TOP RAIL HEAVY-DUTY GALV. LOCKABLE SINGLE GATE LATCH 3/8" DIA. TRUSS ROD WITH TURNBUCKLE AT GATE ONLY #7GA. TENSION WIRE. CONTINUOUS LEDGE U1 M ALTERNATE FOOTING IN LEDGE (SEE NOTE 1) 1" GAP BETWEEN GRADE FINISH AND #2 GROUND BOTTOM OF GATE 12" DIA. CONCRETE FOOTING IN SOIL FOR GATE AND CORNER POSTS. 10" DIA. FOR INTERMEDIATE POSTS STEEL PIPE CAP SPLICE PLATE—\ 1/2" THREADED ROD 4�'*- $ OG FOR SOIL,_ 30, / SEE NOTE 3 FOR BURIED LEDGE, \ SEE NOTE 6 `TOWER PAD COAX CABLE BRIDGE DETAIL CHANNEL STONE OVERT _I (_ GEOTEXTILE FABRIC X* singular WIRELESS W L� Valu F-thues, Inc. 1&10 Mic6x117-6y Drive Su 200 Rr am VA 201W US1 Dynatek] 2-1/2" CORNER POST. 2" FOR INTERMEDIATE POSTS 3/16 X 3/4" STRETCHER BAR AT CORNER AND GATEDRAWN POSTS DT ATEK 4883 PROJ. NO.: BY: J.E.D. CHECKED BY: D.C.B. el SUBMITTALS 5 6/23/05 95% 4 5/19/05 90% 3 1/10/05 95% NO GAP BETWEEN FINISH GRADE AND FENCE FABRIC 2 1/20/05 90% 1 11/19/04 95% 0 10/13/04 90% THIS DOCUMENT IS THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED WORK OF CINGULAR WIRELESS. ANY DUPLICATION OR USE WITHOUT EXPRESS 1 WRITTEN CONSENT IS STRICTLY PROHIBITED. DUPLICATION AND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR LAWFULLY AUTHORIZED REGULATORY AND ADMINISTRATIVE FUNCTIONS IS SPECIFICALLY ALLOWED. ----2x2x3116" STEEL ANGLE 24" LONG GROUND BUS BAR, —GROUND KITS NOT SHOWN FOR CLARITY DRIP LOOP 3/4" EMT / TIE TO GROUND RING SHELTER SCH. 40 PIPE FOR EXPOSED LEDGE, SEE NOTE 4 NOTES: 1. POSITION BRIDGE ASSEMBLY SO THAT WAVEGUIDE ENTERS SHELTER AT WAVEGUIDE BRIDGE PORT CENTERLINE HEIGHT ABOVE GROUND MAY VARY ACCORDING TO SHELTER AND SITE LAYOUT. 2. COAX SHALL BE SLOPED 1/8' PER FOOT AWAY FROM SHELTER. 3. FOR SOIL, USE 12' DLAM. X-6' DEEP PIER FILLED WITH 3000 psi CONCRETE. INSTALL TOP OF PIER FLUSH WITH PROPOSED GRADE AND PROVIDE CROWN FOR DRAINAGE. 4. FOR EXPOSED LEDGE, PROVIDE GROUT LEVELING PAD. INSTALL (2) 5/8' EXPANSION ANCHORS, B' LONG. (NO FIELD WELDING) 5. FOR CONCRETE, FASTEN BASEPLATE W/ (2) 5/8' EXPANSION ANCHORS. 8' LONG. (NO FIELD WELDING) 6. FOR BURIED LEDGE AT LESS THAN X-6' BELOW FINISH GRADE CORE 8' DIA HOLE IWO LEDGE 18' DEEP. FILL AROUND PIPE WITH NON -SHRINK GROUT. USE COAL TAR ON BURIED LENGTH OF PIPE, AND BACKFILL TO FINISH GRADE. 7. FOR POSTS ON CONCRETE OR EXPOSED LEDGE, PROVIDE 4'x8'.3/8' BASEPLATE WITH (2) 11/16' HOLES, 6' O.C. 8. ALL CUT ENDS TO BE COATED WITH CARBOMASTIC 15. RIDINGS HILL #1724 1009 GERMANY ROAD STEPHENS CITY, VA 22655 CONSTRUCTION DETAILS PROJECT: SHE1~A 1724 DATE: 10/13/04 A-3 _ r� i SCALE: 11 �' NO SCALE FOOTING SEE DETAIL 2, A-3 C GATE POSTROADWAY TOP DOUBLE SWING, GATE — CLR SPNGI I DTH VARIES SEE PLANS BAR TENSION WIRE NREEED BRACE RAIL OF BARBED WIRE AT GATE _ STRETCHER PROVIDE BAR INTERMEDIATE' FACILITY SIDE RAILS FOR GATE DIAGONAL ROD OVER 20'-0' OF W/STEEL TOTAL WIDTH TURNBUCKLE GATE FRAME II SIDE FORK LATCH FINISH GRADE, I II WITH LOCK FOOTING SEE DETAIL 2, A-3 TOP STRAND EXTENSION ARMS 0—BAfF$ID-�I� Mr X 'QR FACILITY SIDE WOVEN WIRE SWING GATE, DOUBLE FENCE GATE DETAIL CORNER, GATE, END OR PULL POST BARBEDWIRE CORNER POST DETAIL TOP BRACE RAIL STRETCHER BAR DIAGONAL ROD W/ STEEL TURNBUCKLE BOTTOM TENSION WIRE FINISH GRADE OR GROUND 1 1/2" MAX CLEARANCE FROM GRADE 2 1 TYPICAL ELEVATION POST EXTENSION TOP STRAND ARMS I OF BARBED WIRE 0 I 45• TOP OF FABRIC 0 TOP FACILITY SIDE Z RAIL I PROJECT 1" ABOVE J EXTERIOR_ GROUND AND SLOPE o z cr SIDE I ALL AROUND (TYP) m umI TENSION FIN GRADE OR GROUND WIRE 1 1 I }'{cingular WIRELESS =c Z Z 1 1 F:,.L„... I,,, 1 M40 M.,h-I F... d, ua.,. 2uo Rena,,, VA _GL90 USCI Dynatekl DYNATEK 48x3 PROJ. NO.: DRAWN BY J.E.D. CHECKED BY: D.C.B. SUBMITTALS 5 6/23/05 95% 4 5/19/05 90% 3 1/10/05 95% 2 1/20/05 90% 1 11/19/04 95% 0 10/13/04 90% THIS DOCUMENT IS THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED WORK OF CINGULAR WIRELESS. ANY DUPLICATION OR USE WITHOUT EXPRESS WRITTEN CONSENT IS STRICTLY PROHIBITED. DUPLICATION AND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR LAWFULLY AUTHORIZED REGULATORY AND ADMINISTRATIVE FUNCTIONS IS SPECIFICALLY ALLOWED. 1 112" MAx CLEARANCE , 1j RIDINGS HILL FROM GRADE 41724 LINE POST FOOTING 1009 GERMANY ROAD ( MIN) 8 STEPHENS CITY, VA 22655 ( TYPICAL SECTION FENCE DE"TAILS PROJECT: SHEF,T: 1724 DATE: S/13,0� A_4 scAI.E: 4 FENCE SECTION (TYPICAL) ; NO SCALE " o rx—clgula r 5' X 5' X 6" THK. POURED CONCRETE (BROOM FINISH) wIRLLEss LEFT SIDE 6"X6"-W2.9 x W2.9 6" MIN. #57 STONE I 19' J - - > Wud— F.cd•ue.. 1 VN0 &Iid—I F..&y Drive D 71 Suite �0 e q'_1" 2' 2' 2' 2' 3'_q" Rest"",v.A>_otwusA Z BACKBOARD 0 lllTELCO Dyn atek f .................... . �CONPACTED •.:. SUBGRADE • .... INTERSECT -M, " ,, FUTUR FUTUR FUTURE ... r . ..... .. A/C INTEGRATED o LOAD CENTER- TELECOMMUNICATIONS SERVICES PANELBOARD ......................... ..... .......... . .. . ............. _ 435 Crestview Drive .................................................. .. ......................... Transfer, PA 16154 CONCRETE STOOP 2 .... .... ...... ... .... .. ............... .. Phone: 800.838-3224 a0I.Z7 Fax: 724-646-1384 Dwww.dynatektelecom.conr ......... _.._ A/C .-.-.-. ....................-. ....1... ...'. ..7..&.2............. ........... K 4883 -Ol NO.: ...... .... N---- .STACKED ...................... CHAIN LINK DRAWN BY: I.E.D. FENCE POST MATCH EXISTING STONE 3'-2" 4' TYPICAL 6" OF 6•• --{ [DEPTH #57 STONE A CABLEPORT (TYP) CHECKED BY: DCB I WALL MOUNTED RIGHT SIDE VERTICLE CABLETRAY 01 SUBMITTALS 5 MIL FABRIC ON 5 6/23/05 95% CONPACTED SUBGRADE NOTE: 4 5/19/05 90% ALL EXPOSED GALV. METAL THAT IS CUT OR DAMAGED MUST BE COATED WITH CARBOMASTIC 15. 3 1/10/05 95% 2 1/20/05 90% 1 11/19/04 95% YARD ARRA 3 GSM EQUIPMENT LAYOUT I 0 10/13(04 90% 6" THICK CONIC. SLAB OVER 5 MIL POLY VAPOR BARRIER TOP OF SLAB 6" CONCRETE SLABEL.=+O'-6" THIS DOCUMENT IS THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED NOTE: 70P/GONG- 6X6XW2.9/W2.9 A.F.G. REINFORCED WITH 6X6—W2.9XW2.9WWF (BROOM FINISH W/1" WORK OF CINGULAR WIRELESS. ANY DUPLICATION OR USE WITHOUT EXPRESS WRITTEN CONSPLICATIONENT IS STRICTLY PROHIBITED. SLAB=6"A.F.G.— W.M.M. CONFORMING CHAMFER EDGE) DUAG AGENCIES Fors ire PURPOSESOF TO ASTM A-185 2I •_O» CONDUCTING THEIR LAWFULLY AUTHORIZED REGULATORY AND ADMINISTRATIVE FINISHED GRADE J- c--- < a ° FUNCTIONS 15 SPECIFICALLY ALLOWED --- — 6" #57 STONE ° «� o SUPAC 8 NP i e ° 8" CRUSHED OCK a eV " aQ 1, POLYFELT M M 11 I I■ TS 600 OR EQUAL CONCRETE-4 s I. FOUNDATION —j I a 8< 1 --- If--- --- — --j 2—#5 CONTINUOUS LAPd �-6' ° a a SPLICE 2'-8" AS 1 ° REQUIRED LEFT FRONT PAD MOUNTED EQUIPMENT FOUNDATION FINISHED FOUNDATION PLAN NOTES: 1. ALL FILL/BACKFILL SHALL BE CONPACTED TO A MINIMUM OF 6"X4"X3/8' THICK 95% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY RIDINGS FULL GALVANIZED STEEL (ASTM01557) ANGLE PLATE CONNECTOR 2. PROVIDE 3'-0" #2 AWG COPPER PIGTAIL CADWELDED TO #1724 ® ® (TYP. X4) SHELTER INTERIOR LONGEST REBAR MAMBER STUBBED OUT 6" BELOW FINISHED GRADE FOR CONNECTION TO ELECTRICAL GROUNDING SYSTEM. 1009 GERMANY ROAD 3/4"X1 3/4" BOLT STEPHENS CITY, VA 22655 W/ 3/4" WASHER 3/4" #5 DOWEL BAR 18"L 3. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 0 TYP. X4 ( ) (CAST IN FLOOR) 3,000 PSI ® 28 DAYS AND SHALL BE INSTALLED IN ACCORDANCE WITH THE ACI-318-83 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE. FINISHED GRADE " ;!!!: :jl:�;�ij! SHELTER DETAILS RIGHT BACK 7/8"0 HILT[ HY150 NOTE: SHEET: ANCHORS W/8" MIN. ATTACHMENT FOOTING SHALL BEAR ON SOILS APPROVED FOR 1724 EMBEDMENT ALTER DETAIL 3,000 PSI ALLOWABLE BEARING PRESSURE. LPROJFCT: /13/04C sEXTERIOR ELEVATIONS SHELTER FOUNDATION DETAIL 5i 1 4SCALE _% % % % x X % x % X _ X X _ X _X -X _ X _ X _ X SHELTER WALL PENETRATION. PASS / INTERIOR GROUND LEAD THRU GROUND HVAC UNIT, PENETRATION IN SHELTER WALL. / _ 2 PLACES SEAL OPENING AFTER INSTALLATION. / x _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ----_-------_ _ _ __ ___ ___ i PGB 1 x !CpA1E.•---- / ENTRANCE Y I \I I ( I ;a INSPECTION WELL / /(VERIFY LOCATION W/ PROJECT MGR.) PROPOSED MGB LOCATED / f�AT 845E OF THE TOWER INSTALL GROUNDING KITS AT ANTENNA CENTERLINE, AND TOWER EXIT POINTS. RUN CONDUCTOR DOWN TOWER. SECURED TO COAX MOUNTING BRACKET. TIE INTO GROUNDING SYSTEM GROUND COAX LEADS. GROUNDING LEGEND ■ MECHANICAL CONNECTION EXOTHERMIC WELD GROUND ROD EXOTHERMICALLY TO GROUND RING --$-- ELECTROLYTIC GROUND ROD --�-- GROUND TEST WELL GROUND CONDUCTOR ---_— GROUND ROD kT -- INTERIOR GROUND LEAD GROUNDING PLAN I TELCO GROUND BAR I x INTERSECT INTEGRATED LOAD CENTER PANELBOARD /2 COPPER GROUND RING WITH 5/8" X 8' GROUND RODS AT i6' O.C. (MAX.). X X % CINGULAR GROUNDING NOTES 4.6.1 GENERAL ALL EXTERIOR GROUND CONNECTIONS ABOVE AND BELOW GRADE SHALL BE BY EXOTHERMIC WELD (CADWELD). ALL GROUND CONNECTIONS TO GROUND BARS SHALL BE BY STAINLESS STEEL OR BRASS, TWO HOLE LONG BARREL LUG CONNECTORS AND TREATED WITH ANTI -OXIDANT COATING. ALL CAD WELD CONNECTIONS SHALL BE PERFORMED BY A CERTIFIED TECHNICIAN AND COATED WITH CARBOMASTIC 15. ALL COMPRESSION CONNECTIONS (LONG BARREL LUG CONNECTIONS TO CONDUCTOR, CRIMP CONNECTORS, ETC.), SHALL BE PRESSED USING THE APPROPRIATE DIE AND TOOL, BY THE SAME MANUFACTURER, TO ENSURE THAT THE CONNECTION IS PROPERLY TORQUED. CONNECTORS ARE COLOR CODED TO MATCH THE PROPER DIE AND THE DIE CODE NUMBER SHALL BE EMBOSSED INTO THE CRIMP SURFACE BY THE DIE TO COORDINATE THAT THE PROPER TOOLS HAVE BEEN UTILIZED. 4.6.2 BURIED GROUND RING A 82 AWG, WE. TINNED COPPER RING GROUND SHALL BE INSTALLED 24- AWAY FROM THE PERIMETER OF THE SHELTER FOUNDATION AND BELOW THE FROST UNE (30" MINIMUM BELOW GRADE). THE RING GROUND SHALL BE EXOTHERMICALLY WELDED (CAD WELDED) TO 5/8" DIAMETER X 8'-0" LONG SOLID COPPER CLAD GROUND RODS SPACED 16'-0" APART AND INSTALLED AT THE SAME DEPTH AS THE RING GROUND. CAD WELD CONNECTION SHALL BE "r TYPE AT TOP OF GROUND ROD. ALL GROUND RING INSTALLATIONS SHALL HAVE ONE FEST INSPECTION WELL WHICH SHALL BE LOCATED AT A GROUND ROD WITH THE GROUND WIRE TEST LEAD VISIBLE. INSPECTION WELL SHALL BE A 6" DIAMETER SCHEDULE 40 PVC CONDUIT AND COVER. COVER SHALL BE REMOVABLE BY HAND FOR VISUAL INSPECTION PURPOSES. AN "XIT" CHEMICAL GROUND SYSTEM MAY BE USED IN ADDITION TO OR IN LIEU OF THE BURIED RING GROUND WHERE EXISTING SOIL CONDITIONS ARE AT HIGH OHMIC VALUES AND REQUIRE ADDITIONAL MEANS TO LOWER THE SYSTEM GROUNDING LEVEL TO WITHIN ACCEPTABLE TOLERANCES. 4.6.3 GROUND BARS THE SINGLE POINT OF GROUND REFERENCE WITHIN THE SHELTER SHALL BE THROUGH THE CELL REFERENCE GROUND BAR (CRGB). THE CRGB SHALL BE A PRE -DRILLED 4"X30"X )< THICK COPPER GROUND BAR MOUNTED ON INSULATED STANDOFFS AND ATTACHED DIRECTLY BELOW THE CABLE ENTRY PORT. THE CRAB SHALL BE BONDED TO THE BURIED GROUND RING USING A 82 BARE TINNED GROUND CONDUCTOR THAT IS CAD WELDED TO THE NEAREST BURIED GROUND ROD. THE GROUND CONDUCTOR SHALL ROUTE THROUGH THE SHELTER EXTERIOR WALL THROUGH A Ji- SLEEVED PENETRATION, COAX GROUND BARS (CCB) SHALL BE PROVIDED FOR ANTENNA COAX CABLE GROUNDING KR CONNECTIONS AT THE SHELTER END OF THE CABLE RUN AND AT THE VERTICAL CABLE RUNS UP TO THE ANTENNA LOCATIONS. THE CGB SHALL BE A PRE -DRILLED 4-X24-XI/4- THICK COPPER GROUND BAR MOUNTED ON INSULATED STANDOFFS AND SECURED TO THE UNDERSIDE OF THE COAX CABLE SUPPORT (ICE BRIDGE). THE CGB SHALL BE BONDED TO THE BURIED GROUND RING USING 282 BARE TINNED GROUND CONDUCTORS IN SEPARATE ?" PVC CONDUIT TO GRADE AND BONDED TO THE NEAREST BURIED GROUND ROD. AN ANTENNA SECTOR GROUND BAR SHALL BE PROVIDED AT EACH ANTENNA SECTOR. THE GROUND BAR SHALL BE A PRE -DRILLED 2"X12"Xl/4" THICK COPPER GROUND BAR MOUNTED ON INSULATED STANDOFFS AND INSTALLED WITHIN 10'-0" OF EACH ANTENNA SECTOR. IF ALL COAX GROUND KIT LEADS ADEQUATELY REACH TO A SINGLE LOCATION, ONE GROUND BAR APPROPRIATELY SIZED TO ACCOMMODATE THE TOTAL NUMBER OF GROUND CONNECTIONS REQUIRED, MAY BE USED IN UEU OF SEPARATE GROUND BARS. GROUND KITS SHALL BE INSTALLED WITHIN 24" - 36" OF EACH END OF COAX ON THE TOP OF THE ANTENNA STRUCTURE. A TELCO GROUND BAR SHALL BE PROVIDED ON THE TELEPHONE EQUIPMENT BACKBOARD (TELCOBOARO) INSTALLED WITHIN THE SHELTER. THE GROUND BAR SHALL BE A PRE -DRILLED 4"X12'Xl/4" THICK COPPER GROUND I5AR MOUNTED ON INSULATED STANDOFFS. THE TELCO GROUND BAR SHALL BE BONDED TO THE CRGB USING A 182 AWG, INSULATED, STRANDED CONTINUOUS COPPER GROUND CONDUCTOR, AND TO THE BURIED GROUND RING USING A 82 AWG BARE TINNED COPPER GROUND. BONDING CONNECTION TO THE BURIED GROUND RING SHALL BY CAD WELDING THE CONDUCTOR TO THE NEAREST GROUND ROD. A POLYPHASER GROUND BAR SYSTEM SHALL BE PROVIDED WITHIN THE SHELTER AT CLOSE PROXIMITY TO THE CABLE ENTRY PORT. REFER TO CINGULAR WIRELESS GROUNDING SPECIFICATION FOR DETAILS. THE POLYPHASER GROUND BAR SYSTEM SHALL BE A PRE -MANUFACTURED SERIES OF ADJUSTABLE PREDRILLED BUS BARS BOLTED TO A FRAME AND SUSPENDED FROM THE CABLE TRAY BY MEANS OF ALL THREAD ROD FOR MOUNTING OF THE COAX POLYPHASERS. BOND EACH END OF THE GROUND BAR TO THE CRGB USING A 86 AWG INSULATED STRANDED COPPER GROUND CONDUCTOR (2 TOTAL). ALL GROUND TERMINATIONS/GROUND LEADS AT BUS BARS SHAD. BE TAGGED WITH A ESCRIPTION OF THE CONNECTED DEVICE 4.6.4 INTERIOR GROUNDING A FACTORY INSTALLED INTERIOR GROUND RING (HALO GROUND) SHALL BE PROVIDED AROUND THE PERIMETER OF THE SHELTER AND INSTALLED APPROXIMATELY 8'-6" ABOVE FINISHED FLOOR. THE HALO GROUND RING SHALL CONSIST OF A CONTINUOUS 82 AWG INSULATED, STRANDED COPPER GROUND CONDUCTOR SUPPORTED FROM THE PERIMETER WALLS EVERY 2'-0' ON CENTER USING AN INSULATED STANDOFF (T&B -rY-RAP" STANDOFF BRACKET BTC376). THE ENDS OF THE HALO GROUND RING SHALL BE SPLICED USING A COPPER CRIMP CONNECTOR (T&B 854740 OR APPROVED EQUAL). THE HALO GROUND RING SHALL BE INSTALLED WITH THE LEAST AMOUNT OF BENDS POSSIBLE, WITH THE MINIMUM BENDING RADIUS NOT TO BE LESS THAN 0'-8". EACH CORNER OF THE HALO GROUND RING SMALL BE BONDED TO THE BURIED GROUND RING TO INSURE A LOW IMPEDANCE GROUND PATH, A FACTORY PROVIDED 82 AWG PIG TAIL SHALL EXTEND FROM A NONDIRECTONAL SPLICE CONNECTION OF THE HALO GROUND RING IN EACH CORNER OF THE SHELTER AND SHALL BOND TO A CONTRACTOR INSTALLED 82 AWG TINNED COPPER GROUND LEAD EXTENDING FROM THE BURIED GROUND RING. THE TNNED GROUND LEAD SHALL EXTEND THROUGH THE SLEEVED PENETRATIONS IN EACH CORNER OF THE SHELTER AND CONNECT TO THE INSULATED GROUND PIGTAIL USING A COPPER CRIMP CONNECTOR. PIGTAILS SHALL BE CUT TO ELIMINATE EXCESSIVE LENGTHS. THE HALO GROUND RING IS USED AS A LOW IMPEDANCE GROUND PATH FOR ALL NONTELECOMMUNICATIONS RELATED EQUIPMENT LOCATED WITHIN THE SHELTER. ALL CONNECTGNS TO THE HALO GROUND RING SHALL BE BY A 86 AWG INSULATED GROUND LEAD USING A NON -DIRECTIONAL SPLICE CONNECTION UNLESS OTHERWISE INDICATED: - CELL REFERENCE GROUND BAR (CRGB): BONDING CONNECTION SHALL BE BY 82 AWG INSULATED STRANDED CONDUCTOR BY FACTORY. - CABLE ENTRY PORT: TWO (2) DIRECTIONAL SPLICE CONNECTIONS WITH EACH SPLICE DIRECTED TOWARDS THE GROUND LEAD DROP TO THE EXTERIOR BURIED GROUND RING BY FACTORY. - METAL DOOR FRAME: METAL DOOR AND DOOR FRAME SHALL BE BONDED USING A FLEXIBLE METAL STRAP. DOOR FRAME SHALL BE BONDED TO HALO GROUND RING BY FACTORY. - ELECTRICAL EQUIPMENT ENCLOSURES BY FACTORY. HVAC LOUVERS AND SHEET METAL DUCTWORK BY FACTORY. - CABLE TRAY: EACH END OF CABLE TRAY RUN SHALL BE BONDED TO THE HALO GROUND RING AT THE CLOSEST POINT BY FACTORY. BATTERY FRAMES BY CONTRACTOR. METAL CONDUITS THAT APPROACH THE HALO RING GROUND. - METAL CONDUITS AT THE NEAREST POINT OF THE CABLE ENTRY PORT. 4.6.5 CELLULAR EQUIPMENT GROUNDING EACH CELLULAR EQUIPMENT FRAME (POWERBOARD. TELCO RACK, CELLULAR EQUIPMENT CABINETS) SHALL BE BONDED TO THE CRGB USING A 86 AWG INSULATED COPPER GROUND CONDUCTOR (BY CONTRACTOR). 4.6.6 CABLE TRAY GROUNDING BECAUSE OF THE INTERCONNECTING RUNS AND NOMINAL LENGTHS OF THE CABLE TRAY, THE FOLLOWING GROUNDING CONNECTIONS SHALL BE PROVIDED BY THE FACTORY TO INSURE GROUNDING CONTINUITY: - STRAIGHT SPLICES: A 86 AWG INSULATED STRANDED COPPER BONDING JUMPER SHALL BE PROVIDED ON EACH SIDE OF THE CABLE TRAY. - TEE JUNCTIONS: A 86 AWC INSULATED STRANDED COPPER BONDING JUMPER SHALL BE PROVIDED ON EACH SIDE OF THE CABLE TRAY TEE CONNECTION. MINIMUM BENDING RADIUS OF THE BONDING JUMPER SHALL BE B - ENDS: A 86 AWG INSULATED STRANDED COPPER BONDING JUMPER SHALL BE PROVIDED ONE SIDE OF THE CABLE TRAY RUN AT EACH END. THE BONDING JUMPER SHALL CONNECT TO THE HALO GROUND RING USING A NON -DIRECTIONAL SPUCE CONNECTION. 4.6.7 EXTERIOR GROUNDING THE FOLLOWING ITEMS SHALL BE BONDED TO THE BURIED GROUND RING TO INSURE THAT THE GROUNDING SYSTEM IS AT THE SAME VOLTAGE POTENTIAL: - SHELTER FOUNDATION RAILS: THE METAL FOUNDATION RAILS WHICH SUPPORT THE PREFABRICATED SHELTER SHALL BE BONDED TO THE BURIED GROUND RING AT EACH CORNER LOCATION. THE RAILS SHALL BE CLEAR OF PAINT TO BARE METAL AND CAD WELDED TO A 82 AWG TINNED COPPER GROUND LEAD TO THE NEAREST BURIED GROUND ROD. - EXTERIOR HVAC UNITS: THE METAL FRAMES OF THE THROUGH WALL HVAC UNITS SHALL BE BONDED TO THE BURIED GROUND RING. EACH FRAME SHALL BE CLEAR OF PAINT TO BARE METAL AND UTILIZING A TWO HOLE MECHANICAL CONNECTOR, BONDED TO A 82 AWG TINNED COPPER GROUND LEAD TO THE NEAREST BURIED GROUND ROD. - CHAIN LINK FENCE: EACH CORNER OF A NEW FENCED COMPOUND SHALL BE BONDED TO THE BURIED GROUND RING. WHERE THE EOUIPMENT PAD IS INSTALLED IN AN EXISTING COMPOUND, THE NEAREST FENCE POST SHALL BE BONDED TO THE BURIED GROUND RING. ALL GATES SHALL BE BONDED TO THE ADJACENT FENCE POST USING A FLEXIBLE GROUND STRAP. - ELECTRIC SERVICES: MAIN SERVICE DISCONNECTING MEANS SHALL BE BONDED TO THE NEAREST GROUND ROD WITH A GROUNDING ELECTRODE CONDUCTOR SIZED PER NEC ARTICLE 250-66. ELECTRIC SERVICE EQUIPMENT AT THE EQUIPMENT PAD SHALL BE BONDED TO THE BURIED GROUND RING WITH AN EQUIPMENT GROUNDING CONDUCTOR SIZED PER NEC ARTICLE 250-122. ALL CONNECTION TO ELECTRICAL EQUIPMENT SHALL BE BY MECHANICAL TWO HOLE. LONG BARREL CONNECTORS. - COAX CABLE SUPPORTS (ICE BRIDGE): EACH SUPPORT POST SHALL BE BONDED TO THE NEAREST BURIED GROUND ROD USING A 82 AWG BARE TINNED COPPER CONDUCTOR INSTALLED IN A X" FLEXIBLE CONDUIT TO GRADE. TOWERS EXISTING GROUND RINGS: ADJACENT BURIED GROUND RINGS SURROUNDING OTHER CARRIERS OR TOWER SHALL BE BONDED TO GROUND RING SURROUNDING THE CINGULAR WIRELESS FOUNDATION. CONNECTIONS TO THE EXISTING GROUND RINGS SHALL BE MADE AT THE NEAREST GROUND ROD TO THE NEW GROUND RING. A TEST INSPECTION WELL SHALL BE PROVIDED AT EACH EXISTING GROUND RING CONNECTION. - EXISTING METALLIC ITEMS: EXISTING METALLIC ITEMS WITHIN THE EQUIPMENT COMPOUND SHALL BE BONDED TO THE BURIED GROUND RING. SUCH ITEMS MAY BE EXISTING FUEL TANKS, GENERATORS, METALLIC CONDUITS, ETC. 4.6.8 GROUND RESISTANCE MEASUREMENTS THE GROUND RING SURROUNDING THE NEW EQUIPMENT PAD SHALL BE TESTED TO VERIFY THAT THE RESISTANCE TO GROUND MEASUREMENT IS 5 OHMS OR LESS, TO ALLOW FOR A LOW IMPEDANCE GROUND PATH FOR ANY POTENTIAL FAULT. THE GROUND RING SURROUNDING THE SHELTER FOUNDATION SHALL BE TESTED PRIOR TO ANY ADDITIONAL GROUNDING SYSTEM INTERCONNECTIONS (TELEPHONE/ELECTRIC SERVICES, EXISTING GROUND RINGS, EXISTING FENCE POSTS, ETC.) TO ELIMINATE ANY LOOP CURRENTS. THE GROUND RING SHALL BE TESTED USING A THREE POINT "FALL OF POTENTML METER: FOUR POINT "FALL OF POTENTIAL- METER: TEST METHOD CALCULATES THE GROUND RESISTANCE TO FA RTH BY CIRCULATING AN AC CURRENT BETWEEN TWO AUXILIARY TEST PROBES AND A GROUND LEAD FROM THE GROUND RING. TEST PROBES ARE MOVED TO CALCULATED DISTANCES TO ESTABLISH RESISTANCE READINGS WITHIN THE GROUND PLANE. THE POINTS SHALL BE PLOTTED AND THE SYSTEM RESISTIVITY LEVEL IS TAKEN AT THE CHART PLATEAU (62% AREA). TEST RESULTS SHALL BE SUBMITTED TO CINGULAR WIRELESS Xcingular WIRELESS WA/. R'imlers F.,cihues, Inc 1840 Afwhnd Far.,day Ddv S.m 200 Res VA 201'VUSA "IDynatek� TELECOMMUNICATIONS SERVICES 435 Crestview Drive Transfer, PA 16154 Phone: 800-838-3224 Fax: 724-646-1384 www. dy natekteleco m. com DYNATEK 4883 PROJ. NO.: DRAWN BY: J.E.D. CHECKEDBY: D.C.B. SUBMITTALS 5 6/23/05 95% 4 5/19/05 905F 3 1/10/05 95% 2 1/20/05 90% 1 11/19/04 95% 0 10/13/04 90% ge THIS DOCUMENT IS THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED WORK OF CINGULAR WIRELESS. ANY DUPLICATION OR USE WITHOUT EXPRESS WRITTEN CONSENT IS STRICTLY PROHIBITED. DUPLICATIONAND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR LAWFULLY AUTHORIZED REGULATORY AND ADMINISTRATIVE FUNCTIONS IS SPECIFICALLY ALLOWED. RIDINGS HILL #1724 1009 GERMANY ROAD STEPHENS CITY, VA 22655 GROUNDING PLAN AND DETAILS 1724 E-1 10/13/04 JNO SCALE \ PROPOSED GROUND BAR \ I PLATTED ON THE ANTENNA PLATFORM / PROPOSED TOWER GROUND RING INTERSECT INTEGRATED LOAD CENTER PANELBOARD /2 COPPER GROUND RING WITH 5/8" X 8' GROUND RODS AT i6' O.C. (MAX.). X X % CINGULAR GROUNDING NOTES 4.6.1 GENERAL ALL EXTERIOR GROUND CONNECTIONS ABOVE AND BELOW GRADE SHALL BE BY EXOTHERMIC WELD (CADWELD). ALL GROUND CONNECTIONS TO GROUND BARS SHALL BE BY STAINLESS STEEL OR BRASS, TWO HOLE LONG BARREL LUG CONNECTORS AND TREATED WITH ANTI -OXIDANT COATING. ALL CAD WELD CONNECTIONS SHALL BE PERFORMED BY A CERTIFIED TECHNICIAN AND COATED WITH CARBOMASTIC 15. ALL COMPRESSION CONNECTIONS (LONG BARREL LUG CONNECTIONS TO CONDUCTOR, CRIMP CONNECTORS, ETC.), SHALL BE PRESSED USING THE APPROPRIATE DIE AND TOOL, BY THE SAME MANUFACTURER, TO ENSURE THAT THE CONNECTION IS PROPERLY TORQUED. CONNECTORS ARE COLOR CODED TO MATCH THE PROPER DIE AND THE DIE CODE NUMBER SHALL BE EMBOSSED INTO THE CRIMP SURFACE BY THE DIE TO COORDINATE THAT THE PROPER TOOLS HAVE BEEN UTILIZED. 4.6.2 BURIED GROUND RING A 82 AWG, WE. TINNED COPPER RING GROUND SHALL BE INSTALLED 24- AWAY FROM THE PERIMETER OF THE SHELTER FOUNDATION AND BELOW THE FROST UNE (30" MINIMUM BELOW GRADE). THE RING GROUND SHALL BE EXOTHERMICALLY WELDED (CAD WELDED) TO 5/8" DIAMETER X 8'-0" LONG SOLID COPPER CLAD GROUND RODS SPACED 16'-0" APART AND INSTALLED AT THE SAME DEPTH AS THE RING GROUND. CAD WELD CONNECTION SHALL BE "r TYPE AT TOP OF GROUND ROD. ALL GROUND RING INSTALLATIONS SHALL HAVE ONE FEST INSPECTION WELL WHICH SHALL BE LOCATED AT A GROUND ROD WITH THE GROUND WIRE TEST LEAD VISIBLE. INSPECTION WELL SHALL BE A 6" DIAMETER SCHEDULE 40 PVC CONDUIT AND COVER. COVER SHALL BE REMOVABLE BY HAND FOR VISUAL INSPECTION PURPOSES. AN "XIT" CHEMICAL GROUND SYSTEM MAY BE USED IN ADDITION TO OR IN LIEU OF THE BURIED RING GROUND WHERE EXISTING SOIL CONDITIONS ARE AT HIGH OHMIC VALUES AND REQUIRE ADDITIONAL MEANS TO LOWER THE SYSTEM GROUNDING LEVEL TO WITHIN ACCEPTABLE TOLERANCES. 4.6.3 GROUND BARS THE SINGLE POINT OF GROUND REFERENCE WITHIN THE SHELTER SHALL BE THROUGH THE CELL REFERENCE GROUND BAR (CRGB). THE CRGB SHALL BE A PRE -DRILLED 4"X30"X )< THICK COPPER GROUND BAR MOUNTED ON INSULATED STANDOFFS AND ATTACHED DIRECTLY BELOW THE CABLE ENTRY PORT. THE CRAB SHALL BE BONDED TO THE BURIED GROUND RING USING A 82 BARE TINNED GROUND CONDUCTOR THAT IS CAD WELDED TO THE NEAREST BURIED GROUND ROD. THE GROUND CONDUCTOR SHALL ROUTE THROUGH THE SHELTER EXTERIOR WALL THROUGH A Ji- SLEEVED PENETRATION, COAX GROUND BARS (CCB) SHALL BE PROVIDED FOR ANTENNA COAX CABLE GROUNDING KR CONNECTIONS AT THE SHELTER END OF THE CABLE RUN AND AT THE VERTICAL CABLE RUNS UP TO THE ANTENNA LOCATIONS. THE CGB SHALL BE A PRE -DRILLED 4-X24-XI/4- THICK COPPER GROUND BAR MOUNTED ON INSULATED STANDOFFS AND SECURED TO THE UNDERSIDE OF THE COAX CABLE SUPPORT (ICE BRIDGE). THE CGB SHALL BE BONDED TO THE BURIED GROUND RING USING 282 BARE TINNED GROUND CONDUCTORS IN SEPARATE ?" PVC CONDUIT TO GRADE AND BONDED TO THE NEAREST BURIED GROUND ROD. AN ANTENNA SECTOR GROUND BAR SHALL BE PROVIDED AT EACH ANTENNA SECTOR. THE GROUND BAR SHALL BE A PRE -DRILLED 2"X12"Xl/4" THICK COPPER GROUND BAR MOUNTED ON INSULATED STANDOFFS AND INSTALLED WITHIN 10'-0" OF EACH ANTENNA SECTOR. IF ALL COAX GROUND KIT LEADS ADEQUATELY REACH TO A SINGLE LOCATION, ONE GROUND BAR APPROPRIATELY SIZED TO ACCOMMODATE THE TOTAL NUMBER OF GROUND CONNECTIONS REQUIRED, MAY BE USED IN UEU OF SEPARATE GROUND BARS. GROUND KITS SHALL BE INSTALLED WITHIN 24" - 36" OF EACH END OF COAX ON THE TOP OF THE ANTENNA STRUCTURE. A TELCO GROUND BAR SHALL BE PROVIDED ON THE TELEPHONE EQUIPMENT BACKBOARD (TELCOBOARO) INSTALLED WITHIN THE SHELTER. THE GROUND BAR SHALL BE A PRE -DRILLED 4"X12'Xl/4" THICK COPPER GROUND I5AR MOUNTED ON INSULATED STANDOFFS. THE TELCO GROUND BAR SHALL BE BONDED TO THE CRGB USING A 182 AWG, INSULATED, STRANDED CONTINUOUS COPPER GROUND CONDUCTOR, AND TO THE BURIED GROUND RING USING A 82 AWG BARE TINNED COPPER GROUND. BONDING CONNECTION TO THE BURIED GROUND RING SHALL BY CAD WELDING THE CONDUCTOR TO THE NEAREST GROUND ROD. A POLYPHASER GROUND BAR SYSTEM SHALL BE PROVIDED WITHIN THE SHELTER AT CLOSE PROXIMITY TO THE CABLE ENTRY PORT. REFER TO CINGULAR WIRELESS GROUNDING SPECIFICATION FOR DETAILS. THE POLYPHASER GROUND BAR SYSTEM SHALL BE A PRE -MANUFACTURED SERIES OF ADJUSTABLE PREDRILLED BUS BARS BOLTED TO A FRAME AND SUSPENDED FROM THE CABLE TRAY BY MEANS OF ALL THREAD ROD FOR MOUNTING OF THE COAX POLYPHASERS. BOND EACH END OF THE GROUND BAR TO THE CRGB USING A 86 AWG INSULATED STRANDED COPPER GROUND CONDUCTOR (2 TOTAL). ALL GROUND TERMINATIONS/GROUND LEADS AT BUS BARS SHAD. BE TAGGED WITH A ESCRIPTION OF THE CONNECTED DEVICE 4.6.4 INTERIOR GROUNDING A FACTORY INSTALLED INTERIOR GROUND RING (HALO GROUND) SHALL BE PROVIDED AROUND THE PERIMETER OF THE SHELTER AND INSTALLED APPROXIMATELY 8'-6" ABOVE FINISHED FLOOR. THE HALO GROUND RING SHALL CONSIST OF A CONTINUOUS 82 AWG INSULATED, STRANDED COPPER GROUND CONDUCTOR SUPPORTED FROM THE PERIMETER WALLS EVERY 2'-0' ON CENTER USING AN INSULATED STANDOFF (T&B -rY-RAP" STANDOFF BRACKET BTC376). THE ENDS OF THE HALO GROUND RING SHALL BE SPLICED USING A COPPER CRIMP CONNECTOR (T&B 854740 OR APPROVED EQUAL). THE HALO GROUND RING SHALL BE INSTALLED WITH THE LEAST AMOUNT OF BENDS POSSIBLE, WITH THE MINIMUM BENDING RADIUS NOT TO BE LESS THAN 0'-8". EACH CORNER OF THE HALO GROUND RING SMALL BE BONDED TO THE BURIED GROUND RING TO INSURE A LOW IMPEDANCE GROUND PATH, A FACTORY PROVIDED 82 AWG PIG TAIL SHALL EXTEND FROM A NONDIRECTONAL SPLICE CONNECTION OF THE HALO GROUND RING IN EACH CORNER OF THE SHELTER AND SHALL BOND TO A CONTRACTOR INSTALLED 82 AWG TINNED COPPER GROUND LEAD EXTENDING FROM THE BURIED GROUND RING. THE TNNED GROUND LEAD SHALL EXTEND THROUGH THE SLEEVED PENETRATIONS IN EACH CORNER OF THE SHELTER AND CONNECT TO THE INSULATED GROUND PIGTAIL USING A COPPER CRIMP CONNECTOR. PIGTAILS SHALL BE CUT TO ELIMINATE EXCESSIVE LENGTHS. THE HALO GROUND RING IS USED AS A LOW IMPEDANCE GROUND PATH FOR ALL NONTELECOMMUNICATIONS RELATED EQUIPMENT LOCATED WITHIN THE SHELTER. ALL CONNECTGNS TO THE HALO GROUND RING SHALL BE BY A 86 AWG INSULATED GROUND LEAD USING A NON -DIRECTIONAL SPLICE CONNECTION UNLESS OTHERWISE INDICATED: - CELL REFERENCE GROUND BAR (CRGB): BONDING CONNECTION SHALL BE BY 82 AWG INSULATED STRANDED CONDUCTOR BY FACTORY. - CABLE ENTRY PORT: TWO (2) DIRECTIONAL SPLICE CONNECTIONS WITH EACH SPLICE DIRECTED TOWARDS THE GROUND LEAD DROP TO THE EXTERIOR BURIED GROUND RING BY FACTORY. - METAL DOOR FRAME: METAL DOOR AND DOOR FRAME SHALL BE BONDED USING A FLEXIBLE METAL STRAP. DOOR FRAME SHALL BE BONDED TO HALO GROUND RING BY FACTORY. - ELECTRICAL EQUIPMENT ENCLOSURES BY FACTORY. HVAC LOUVERS AND SHEET METAL DUCTWORK BY FACTORY. - CABLE TRAY: EACH END OF CABLE TRAY RUN SHALL BE BONDED TO THE HALO GROUND RING AT THE CLOSEST POINT BY FACTORY. BATTERY FRAMES BY CONTRACTOR. METAL CONDUITS THAT APPROACH THE HALO RING GROUND. - METAL CONDUITS AT THE NEAREST POINT OF THE CABLE ENTRY PORT. 4.6.5 CELLULAR EQUIPMENT GROUNDING EACH CELLULAR EQUIPMENT FRAME (POWERBOARD. TELCO RACK, CELLULAR EQUIPMENT CABINETS) SHALL BE BONDED TO THE CRGB USING A 86 AWG INSULATED COPPER GROUND CONDUCTOR (BY CONTRACTOR). 4.6.6 CABLE TRAY GROUNDING BECAUSE OF THE INTERCONNECTING RUNS AND NOMINAL LENGTHS OF THE CABLE TRAY, THE FOLLOWING GROUNDING CONNECTIONS SHALL BE PROVIDED BY THE FACTORY TO INSURE GROUNDING CONTINUITY: - STRAIGHT SPLICES: A 86 AWG INSULATED STRANDED COPPER BONDING JUMPER SHALL BE PROVIDED ON EACH SIDE OF THE CABLE TRAY. - TEE JUNCTIONS: A 86 AWC INSULATED STRANDED COPPER BONDING JUMPER SHALL BE PROVIDED ON EACH SIDE OF THE CABLE TRAY TEE CONNECTION. MINIMUM BENDING RADIUS OF THE BONDING JUMPER SHALL BE B - ENDS: A 86 AWG INSULATED STRANDED COPPER BONDING JUMPER SHALL BE PROVIDED ONE SIDE OF THE CABLE TRAY RUN AT EACH END. THE BONDING JUMPER SHALL CONNECT TO THE HALO GROUND RING USING A NON -DIRECTIONAL SPUCE CONNECTION. 4.6.7 EXTERIOR GROUNDING THE FOLLOWING ITEMS SHALL BE BONDED TO THE BURIED GROUND RING TO INSURE THAT THE GROUNDING SYSTEM IS AT THE SAME VOLTAGE POTENTIAL: - SHELTER FOUNDATION RAILS: THE METAL FOUNDATION RAILS WHICH SUPPORT THE PREFABRICATED SHELTER SHALL BE BONDED TO THE BURIED GROUND RING AT EACH CORNER LOCATION. THE RAILS SHALL BE CLEAR OF PAINT TO BARE METAL AND CAD WELDED TO A 82 AWG TINNED COPPER GROUND LEAD TO THE NEAREST BURIED GROUND ROD. - EXTERIOR HVAC UNITS: THE METAL FRAMES OF THE THROUGH WALL HVAC UNITS SHALL BE BONDED TO THE BURIED GROUND RING. EACH FRAME SHALL BE CLEAR OF PAINT TO BARE METAL AND UTILIZING A TWO HOLE MECHANICAL CONNECTOR, BONDED TO A 82 AWG TINNED COPPER GROUND LEAD TO THE NEAREST BURIED GROUND ROD. - CHAIN LINK FENCE: EACH CORNER OF A NEW FENCED COMPOUND SHALL BE BONDED TO THE BURIED GROUND RING. WHERE THE EOUIPMENT PAD IS INSTALLED IN AN EXISTING COMPOUND, THE NEAREST FENCE POST SHALL BE BONDED TO THE BURIED GROUND RING. ALL GATES SHALL BE BONDED TO THE ADJACENT FENCE POST USING A FLEXIBLE GROUND STRAP. - ELECTRIC SERVICES: MAIN SERVICE DISCONNECTING MEANS SHALL BE BONDED TO THE NEAREST GROUND ROD WITH A GROUNDING ELECTRODE CONDUCTOR SIZED PER NEC ARTICLE 250-66. ELECTRIC SERVICE EQUIPMENT AT THE EQUIPMENT PAD SHALL BE BONDED TO THE BURIED GROUND RING WITH AN EQUIPMENT GROUNDING CONDUCTOR SIZED PER NEC ARTICLE 250-122. ALL CONNECTION TO ELECTRICAL EQUIPMENT SHALL BE BY MECHANICAL TWO HOLE. LONG BARREL CONNECTORS. - COAX CABLE SUPPORTS (ICE BRIDGE): EACH SUPPORT POST SHALL BE BONDED TO THE NEAREST BURIED GROUND ROD USING A 82 AWG BARE TINNED COPPER CONDUCTOR INSTALLED IN A X" FLEXIBLE CONDUIT TO GRADE. TOWERS EXISTING GROUND RINGS: ADJACENT BURIED GROUND RINGS SURROUNDING OTHER CARRIERS OR TOWER SHALL BE BONDED TO GROUND RING SURROUNDING THE CINGULAR WIRELESS FOUNDATION. CONNECTIONS TO THE EXISTING GROUND RINGS SHALL BE MADE AT THE NEAREST GROUND ROD TO THE NEW GROUND RING. A TEST INSPECTION WELL SHALL BE PROVIDED AT EACH EXISTING GROUND RING CONNECTION. - EXISTING METALLIC ITEMS: EXISTING METALLIC ITEMS WITHIN THE EQUIPMENT COMPOUND SHALL BE BONDED TO THE BURIED GROUND RING. SUCH ITEMS MAY BE EXISTING FUEL TANKS, GENERATORS, METALLIC CONDUITS, ETC. 4.6.8 GROUND RESISTANCE MEASUREMENTS THE GROUND RING SURROUNDING THE NEW EQUIPMENT PAD SHALL BE TESTED TO VERIFY THAT THE RESISTANCE TO GROUND MEASUREMENT IS 5 OHMS OR LESS, TO ALLOW FOR A LOW IMPEDANCE GROUND PATH FOR ANY POTENTIAL FAULT. THE GROUND RING SURROUNDING THE SHELTER FOUNDATION SHALL BE TESTED PRIOR TO ANY ADDITIONAL GROUNDING SYSTEM INTERCONNECTIONS (TELEPHONE/ELECTRIC SERVICES, EXISTING GROUND RINGS, EXISTING FENCE POSTS, ETC.) TO ELIMINATE ANY LOOP CURRENTS. THE GROUND RING SHALL BE TESTED USING A THREE POINT "FALL OF POTENTML METER: FOUR POINT "FALL OF POTENTIAL- METER: TEST METHOD CALCULATES THE GROUND RESISTANCE TO FA RTH BY CIRCULATING AN AC CURRENT BETWEEN TWO AUXILIARY TEST PROBES AND A GROUND LEAD FROM THE GROUND RING. TEST PROBES ARE MOVED TO CALCULATED DISTANCES TO ESTABLISH RESISTANCE READINGS WITHIN THE GROUND PLANE. THE POINTS SHALL BE PLOTTED AND THE SYSTEM RESISTIVITY LEVEL IS TAKEN AT THE CHART PLATEAU (62% AREA). TEST RESULTS SHALL BE SUBMITTED TO CINGULAR WIRELESS Xcingular WIRELESS WA/. R'imlers F.,cihues, Inc 1840 Afwhnd Far.,day Ddv S.m 200 Res VA 201'VUSA "IDynatek� TELECOMMUNICATIONS SERVICES 435 Crestview Drive Transfer, PA 16154 Phone: 800-838-3224 Fax: 724-646-1384 www. dy natekteleco m. com DYNATEK 4883 PROJ. NO.: DRAWN BY: J.E.D. CHECKEDBY: D.C.B. SUBMITTALS 5 6/23/05 95% 4 5/19/05 905F 3 1/10/05 95% 2 1/20/05 90% 1 11/19/04 95% 0 10/13/04 90% ge THIS DOCUMENT IS THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED WORK OF CINGULAR WIRELESS. ANY DUPLICATION OR USE WITHOUT EXPRESS WRITTEN CONSENT IS STRICTLY PROHIBITED. DUPLICATIONAND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR LAWFULLY AUTHORIZED REGULATORY AND ADMINISTRATIVE FUNCTIONS IS SPECIFICALLY ALLOWED. RIDINGS HILL #1724 1009 GERMANY ROAD STEPHENS CITY, VA 22655 GROUNDING PLAN AND DETAILS 1724 E-1 10/13/04 JNO SCALE ( BUTTERFLY TYR //6 FROM COAXIAL 20" ASSECLAMP MBLY GROUND BAR CABLE GROUNDING KITS #6 FROM ICEBRIDGE wir () 1" (GROUND O CONNECTION) ENTRY PANEL FROM LE 2o 0 0 0 0 o o o o o e(WHITE) o o o o o o o o o o o o o1 POLARIZATION _ o 0 o o o o o o o o o o o o o 2"RIB 2 t0o 0 o o !p\ 3o o o o ooooooo o o INSULATORS ON HOT (BLACK) GROUNDING KITS FROM CPS MOUNTING BRACKETS HOLE FOR #2 EXOTHFRMICALI_Y NOTES: MOUNTING 1 3 WELDED TO BAR 1. GROUND BAR IS PROVIDED WITH SHELTER. BRACKETS BARE #2 DOWN TO 2. GROUND BAR IS MOUNTED BELOW CABLE ENTRY PANEL HOT (RED) NOT USED CINGULAR GROUND RING ON SHELTER EXTERIOR. 0 GROUND BAR 2 FRONT VIEW 10" DIAMETER PVC TEST WELL WITH CAST IRON GRATE COVER (HARDER BURIED GROUND RING CAT. 360-P) GROUND BAR POLARIZATION FINAL GRADE (GROUND RIB - - CONNECTION) V, 0 (WHITE) HOT (BLACK) O . 2- - PIG TAIL TESTING END 12" FILL WITH SAND 3 i NHOT (RED) NOT USED O MOUNTING RING BACK VIEW X cingular l9IRELESS %V-1- Fa ilio, Inc. 1610 Mid -I F.-d.y Dd- S"im 200 R--, VA 201% USA Dynatek TELECOMMUNICATIONS SERVICES 435 Crestview Drive Transfer, PA 16154 Phone: 800-838-3224 Fax 724-646-1384 www. dy natektelecom. com DYNATEK 4883 PROJ. NO.: DRAWN BY: J.E.D. CHECKEDBY: D.C.B. PANEL PD CAPACITY: 72 kV PANEL PO GROUND ROD CONNECTED LOAD: 30.4 kVA NOTE: (TYP) THE CONNECTED LOAAUMIS NOT EXCEED SUBMITTALS WIRES SHALL BE 400 AMP WIRING PANEL PD'S CAPACITY LUGS ARE NUMBERED INSIDE. PANELBOARD NOTES 1. PANELBOARD: PREMANUFACTURED MODULAR 5 6/23/05 957 CAT. No. AJA40144-400-RS UNIT CONTAINING. (120/240, 10, 3W, 400AMP SERVICE) o. LOAD CENTER 4 5/19/05 90% b. TRANSFER SWITCH c. (2) 300 AMP MAIN CIRCUIT BREAKERS 3 1/10/05 95% GENERATOR PLUG DETAIL 4 GROUND TEST WELL 3 PANEL SCHEDULE 1 2 1/20/05 907 1 11/19/04 957. -�--- 0 10/13/04 90% ELECTRICAL BILL OF MATERIAL PANEL - PB ITEM CABLES FURNISHED BY 120/240 VOLTS 1 PHASE 3 WARE 300 AMP MCB & INSTALL BY BRACKET OR EQUIVALENT COPPER WIRE MP432R 2 ANTENNA CONTRACTOR 2'-0" ON CENTER MAXIMUM (HALO GROUND RING) DESCRIPTION 3 60OV, 4 POLE, 400 AMP RAINTIGHT GENERATOR RECEPTACLE SPACING kJA 40144 -400 -RS DESCRIPTION WAVEGUIDE PORTS AMPS R T A B T R AMPS OUTLINE OF ROOF INTERSECT MA -1240061-U 28 1 28.0 2 20 BARE COPPER TELCO HVAC #1 28 50 3 30.4 4 20 2.4 RECEPTACLE INTERIOR LIGHTS 8.3 20 5 14.7 6 20 6.4 INTERIOR OF! RECEPTACLE 1.2 20 7 2g 2 8 28 RECEPTACLE 6.0 9 34.0 10 50 28 RECTIFIER 1/1 30 HVAC #2 6.0 11 12.0 12 30 6.0 6.0 13 12.0 14 6.0 RECTIFIER #3 6.0 30 15 12.0 16 6.0 RECIFlER /2 6.0 17 12.0 18 30 6.0 RECTIFIER #5 6.0 30 19 12.0 20 6.0 RECIFlER 04 6.0 21 12.01,,-'22 30 6.0 RECTIFIER /7 30RECIFlER /6 6.0 23 12.0 24 30 6.0 RECTIFIER #9 6.0 30 25 12.0 26 6.0 RECIFlER #8 6.0 27 12.0128 6.0 30 EXTERIOR LIGHTS 1.2 20 29 7.2 z30 6.0 RECIFlER /10 SMOKE DETECTOR 0.5 20 31 Z 1.7 32 20 1.2 INTERIOR RECEPTACLE SPARE 20 33 34 20 SPARE SPACE 35 36 - SPACE SPACE 37 38 - SPACE SPACE 39 40 - SPACE SPACE 41 42 - SPACE PHASE TOTALS: V31.91121.31 SPACE 15.8 14.6 kVA X cingular l9IRELESS %V-1- Fa ilio, Inc. 1610 Mid -I F.-d.y Dd- S"im 200 R--, VA 201% USA Dynatek TELECOMMUNICATIONS SERVICES 435 Crestview Drive Transfer, PA 16154 Phone: 800-838-3224 Fax 724-646-1384 www. dy natektelecom. com DYNATEK 4883 PROJ. NO.: DRAWN BY: J.E.D. CHECKEDBY: D.C.B. PANEL PD CAPACITY: 72 kV PANEL PO GROUND ROD CONNECTED LOAD: 30.4 kVA NOTE: (TYP) THE CONNECTED LOAAUMIS NOT EXCEED SUBMITTALS WIRES SHALL BE 400 AMP WIRING PANEL PD'S CAPACITY LUGS ARE NUMBERED INSIDE. PANELBOARD NOTES 1. PANELBOARD: PREMANUFACTURED MODULAR 5 6/23/05 957 CAT. No. AJA40144-400-RS UNIT CONTAINING. (120/240, 10, 3W, 400AMP SERVICE) o. LOAD CENTER 4 5/19/05 90% b. TRANSFER SWITCH c. (2) 300 AMP MAIN CIRCUIT BREAKERS 3 1/10/05 95% GENERATOR PLUG DETAIL 4 GROUND TEST WELL 3 PANEL SCHEDULE 1 2 1/20/05 907 1 11/19/04 957. -�--- 0 10/13/04 90% THIS DOCUMENT IS THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED WORK OF CINGULAR WIRELESS. ANY DUPLICATION OR USE WITHOUT EXPRESS WRITTEN CONSENT IS STRICTLY PROHIBITED. DUPLICATION AND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR LAWFULLY AUTHORIZED REGULATORY AND ADMINISTRATIVE FUNCTIONS IS SPECIFICALLY ALLOWED. POLYPHASER MOUNTING SHINER NOT TO EXCEED 8" MINIMUM (TYP) BRACKET FURNISH BY 1/8 INCH (TYR) & INSTALL BY 1"-±1/8 INCH (MAX)(TYP) GREEN INSULATED ANTENNA CONTRACTOR STRANDED COPPER CONDUCTOR ELECTRICAL BILL OF MATERIAL SIZE AS INDICATED ON POLYPHASER FURNISHED COPPER CIMP CONNECTOR FLOOR PLAN - GROUNDING METAL UTILITY & INSTALL BY T&B CO. CAT. #54730 OR (TYR) COAX CABLE COAX CABLE GROUND KITS SUPPORT FRAME ANTENNA CONTRACTOR APPROVED EQUAL (TYR) COAX CABLE GROUND KITS GROUND CONDUCTOR TO BOND ICEBRIDGE AT EACH END EQUIPMENT, GROUND BAR, ETC. GROUND WIRE KITS DETAIL 5 ITEM i (NOTE i.) ICEBRIDGE CINGULAR SHELTER INTERIOR POLYPHASE GROUND BAR DETAIL 5 MASTER GROUND BAR DETAIL 5 ITEM 2 DINGS HILL BY BUILDING MANUFACTURER�7 NON -DIRECTIONAL SPLICE 7 GROUND BAR WITH MAIN GROUND BAR ITEM 3 I / 2 ^ EXISTING WALL INSULATORS SECURED TO / `t HEAT SHRINK TOWER WITH STAINLESS INTERNAL "HALO" M 1009 GERMANY ROAD EXTERIOR GROUND BAR BY $/S NUT STEEL BEAM CLAMPS DRIP LOOP GROUBNADR GROUND RING SHELTER MANUFACTURER, VERIFY 1" 1 STEPHEN$ CITY, VA 22655 GROUND WIRE FROM GROUND BAR EXACT PLACEMENT IN FIELD WITH MIN. LABEL (2) GROUND WARES BONDED TO GROUND RING CONSTRUCTION MANAGER /S LOCK MIN. IN GROUND OUPDCRING GROUND WIRE ROUTED TO EXTERIOR AND BONDED TO GROUND RING CA GROD WIRE TO POSTD AND 6ROl1NDI RING BOND STEEL BASE GROUNDING AND GRADE ELECTRICAL ALL FOUR CORNERS -/DETAILS COPPER BUSS LJ LJ 2 BTCW 30" BELOW GRADE BONDING clNcuLAR SHELTER PROJECT: SHEET: S/S FLATGROUND RING SERVICE ENTRANCE 1724 WASHER CINGULAR GROUND RING TO EXISTING #2 BTCW 30" BELOW GRADE GROUND ROD DATE: 2 BOLT S/S FLAT /,"TSHRINK ELECTRODE SYSTEM E EXISTING ELECTRODE SYSTEM 10/13/04 SCALE: COAX GROUNDING DETAIL AT POLYPHASER 9 LUG DETAIL 8 1 GROUNDING RISER 6 NOSCALE ELECTRICAL BILL OF MATERIAL T&B CO. "TY -RAP", CAT 2 AWG GREEN ITEM CABLES FURNISHED BY #TC376 STAND-OFF INSULATED STRANDED PART NUMBER 1 & INSTALL BY BRACKET OR EQUIVALENT COPPER WIRE MP432R 2 ANTENNA CONTRACTOR 2'-0" ON CENTER MAXIMUM (HALO GROUND RING) HU363RB 3 60OV, 4 POLE, 400 AMP RAINTIGHT GENERATOR RECEPTACLE SPACING kJA 40144 -400 -RS 4 WAVEGUIDE PORTS INSULATION (TYP) F-04P24BPN-5E 5 OUTLINE OF ROOF INTERSECT MA -1240061-U 6 EMERGENCY BATTERY PACK LIGHT IN SHELTER BY FACTORY BARE COPPER 7 TELCO RACK (IN SHELTER BY FACTORY T&B CO. •7Y -RAP" CAT. (TYP) 8 (2) TWO, 25 PAIR, 24 AWG CAT 5 CABLE, DIRECT BURIAL, RODENT RESISTANT, ANIXTER CAT #E-002524AFO-5, SUPERIOR C 04-097-37, 24-25P EXCHANGE CABLE PE -39, CAT 5 SOLID/FILLED CORE/CACSP FIN. CEILING #TY25M CABLE TIE OR RADIUS OF BOND CONDUCTOR EQUIVALENT SHALL BE i' O" NOMINAL THIS DOCUMENT IS THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED WORK OF CINGULAR WIRELESS. ANY DUPLICATION OR USE WITHOUT EXPRESS WRITTEN CONSENT IS STRICTLY PROHIBITED. DUPLICATION AND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR LAWFULLY AUTHORIZED REGULATORY AND ADMINISTRATIVE FUNCTIONS IS SPECIFICALLY ALLOWED. POLYPHASER MOUNTING SHINER NOT TO EXCEED 8" MINIMUM (TYP) BRACKET FURNISH BY 1/8 INCH (TYR) & INSTALL BY 1"-±1/8 INCH (MAX)(TYP) GREEN INSULATED ANTENNA CONTRACTOR STRANDED COPPER CONDUCTOR ELECTRICAL BILL OF MATERIAL SIZE AS INDICATED ON POLYPHASER FURNISHED COPPER CIMP CONNECTOR FLOOR PLAN - GROUNDING METAL UTILITY & INSTALL BY T&B CO. CAT. #54730 OR (TYR) COAX CABLE COAX CABLE GROUND KITS SUPPORT FRAME ANTENNA CONTRACTOR APPROVED EQUAL (TYR) COAX CABLE GROUND KITS GROUND CONDUCTOR TO BOND ICEBRIDGE AT EACH END EQUIPMENT, GROUND BAR, ETC. GROUND WIRE KITS DETAIL 5 ITEM i (NOTE i.) ICEBRIDGE CINGULAR SHELTER INTERIOR POLYPHASE GROUND BAR DETAIL 5 MASTER GROUND BAR DETAIL 5 ITEM 2 DINGS HILL BY BUILDING MANUFACTURER�7 NON -DIRECTIONAL SPLICE 7 GROUND BAR WITH MAIN GROUND BAR ITEM 3 I / 2 ^ EXISTING WALL INSULATORS SECURED TO / `t HEAT SHRINK TOWER WITH STAINLESS INTERNAL "HALO" M 1009 GERMANY ROAD EXTERIOR GROUND BAR BY $/S NUT STEEL BEAM CLAMPS DRIP LOOP GROUBNADR GROUND RING SHELTER MANUFACTURER, VERIFY 1" 1 STEPHEN$ CITY, VA 22655 GROUND WIRE FROM GROUND BAR EXACT PLACEMENT IN FIELD WITH MIN. LABEL (2) GROUND WARES BONDED TO GROUND RING CONSTRUCTION MANAGER /S LOCK MIN. IN GROUND OUPDCRING GROUND WIRE ROUTED TO EXTERIOR AND BONDED TO GROUND RING CA GROD WIRE TO POSTD AND 6ROl1NDI RING BOND STEEL BASE GROUNDING AND GRADE ELECTRICAL ALL FOUR CORNERS -/DETAILS COPPER BUSS LJ LJ 2 BTCW 30" BELOW GRADE BONDING clNcuLAR SHELTER PROJECT: SHEET: S/S FLATGROUND RING SERVICE ENTRANCE 1724 WASHER CINGULAR GROUND RING TO EXISTING #2 BTCW 30" BELOW GRADE GROUND ROD DATE: 2 BOLT S/S FLAT /,"TSHRINK ELECTRODE SYSTEM E EXISTING ELECTRODE SYSTEM 10/13/04 SCALE: COAX GROUNDING DETAIL AT POLYPHASER 9 LUG DETAIL 8 1 GROUNDING RISER 6 NOSCALE ELECTRICAL BILL OF MATERIAL ITEM # DESCRIPTION MANUFACTURER PART NUMBER 1 METER PAK METER CENTER, 400 AMP, 3 SOCKET WITH CT CABINET SQUARE D MP432R 2 24OV, 2 POLE, 400 AMP, SERVICE ENTRANCE RATED DISCONNECT SWITCH FUSED AT 400 AMP SQUARE D HU363RB 3 60OV, 4 POLE, 400 AMP RAINTIGHT GENERATOR RECEPTACLE APPLETON kJA 40144 -400 -RS 4 CABLE T-1 ANIXTER F-04P24BPN-5E 5 INTERSECT 400A, 240V, 1 PHASE, 42 SINGLE POLE POSITION COMBINATION PANELBOARD/MANUAL TRANSFER SWITCH WITH INTERNAL SURGE ARRESTOR IN SHELTER BY FACTORY INTERSECT MA -1240061-U 6 EMERGENCY BATTERY PACK LIGHT IN SHELTER BY FACTORY 7 TELCO RACK (IN SHELTER BY FACTORY 8 (2) TWO, 25 PAIR, 24 AWG CAT 5 CABLE, DIRECT BURIAL, RODENT RESISTANT, ANIXTER CAT #E-002524AFO-5, SUPERIOR C 04-097-37, 24-25P EXCHANGE CABLE PE -39, CAT 5 SOLID/FILLED CORE/CACSP ANIXTER E-002524AFO-5 THIS DOCUMENT IS THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED WORK OF CINGULAR WIRELESS. ANY DUPLICATION OR USE WITHOUT EXPRESS WRITTEN CONSENT IS STRICTLY PROHIBITED. DUPLICATION AND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR LAWFULLY AUTHORIZED REGULATORY AND ADMINISTRATIVE FUNCTIONS IS SPECIFICALLY ALLOWED. POLYPHASER MOUNTING SHINER NOT TO EXCEED 8" MINIMUM (TYP) BRACKET FURNISH BY 1/8 INCH (TYR) & INSTALL BY 1"-±1/8 INCH (MAX)(TYP) GREEN INSULATED ANTENNA CONTRACTOR STRANDED COPPER CONDUCTOR ELECTRICAL BILL OF MATERIAL SIZE AS INDICATED ON POLYPHASER FURNISHED COPPER CIMP CONNECTOR FLOOR PLAN - GROUNDING METAL UTILITY & INSTALL BY T&B CO. CAT. #54730 OR (TYR) COAX CABLE COAX CABLE GROUND KITS SUPPORT FRAME ANTENNA CONTRACTOR APPROVED EQUAL (TYR) COAX CABLE GROUND KITS GROUND CONDUCTOR TO BOND ICEBRIDGE AT EACH END EQUIPMENT, GROUND BAR, ETC. GROUND WIRE KITS DETAIL 5 ITEM i (NOTE i.) ICEBRIDGE CINGULAR SHELTER INTERIOR POLYPHASE GROUND BAR DETAIL 5 MASTER GROUND BAR DETAIL 5 ITEM 2 DINGS HILL BY BUILDING MANUFACTURER�7 NON -DIRECTIONAL SPLICE 7 GROUND BAR WITH MAIN GROUND BAR ITEM 3 I / 2 ^ EXISTING WALL INSULATORS SECURED TO / `t HEAT SHRINK TOWER WITH STAINLESS INTERNAL "HALO" M 1009 GERMANY ROAD EXTERIOR GROUND BAR BY $/S NUT STEEL BEAM CLAMPS DRIP LOOP GROUBNADR GROUND RING SHELTER MANUFACTURER, VERIFY 1" 1 STEPHEN$ CITY, VA 22655 GROUND WIRE FROM GROUND BAR EXACT PLACEMENT IN FIELD WITH MIN. LABEL (2) GROUND WARES BONDED TO GROUND RING CONSTRUCTION MANAGER /S LOCK MIN. IN GROUND OUPDCRING GROUND WIRE ROUTED TO EXTERIOR AND BONDED TO GROUND RING CA GROD WIRE TO POSTD AND 6ROl1NDI RING BOND STEEL BASE GROUNDING AND GRADE ELECTRICAL ALL FOUR CORNERS -/DETAILS COPPER BUSS LJ LJ 2 BTCW 30" BELOW GRADE BONDING clNcuLAR SHELTER PROJECT: SHEET: S/S FLATGROUND RING SERVICE ENTRANCE 1724 WASHER CINGULAR GROUND RING TO EXISTING #2 BTCW 30" BELOW GRADE GROUND ROD DATE: 2 BOLT S/S FLAT /,"TSHRINK ELECTRODE SYSTEM E EXISTING ELECTRODE SYSTEM 10/13/04 SCALE: COAX GROUNDING DETAIL AT POLYPHASER 9 LUG DETAIL 8 1 GROUNDING RISER 6 NOSCALE CADWELD DETAILS 4 1 TELCO ENTRY DETAIL QUABBIN P/N 9788 DETAIL 4 CINGULAR SHELTER ON TURN DOWN SLAB SHEET E-2 POWER UNIT WITH DETAIL 5 INTEGRAL MAINS, ITEM 5 TRANSFER SWITCH, TVSS, AND PANELBOARD (SUPPLIED W/ SHELTER) TRANSFER SWITCH TELCO BOARD NORMAL CIRCUIT BREAKER RATED ®400 AMPS �T T U"11 L!"I'Y DIAGRAM urawmg rypt ' or "" tamuy PREFAB FODI��IT I SHELTER BUILDING � TELCO BOARD ILII/// Imo_ CONDUIT IN THE SHELTER I NEEDS ?0 BE SEALED 7/ 11771/ ON BOTH ENDS AFTER TELCO LINE IS INSTALLED. CONDUIT AT TELCO END SHALL BE WEATHER SEALED WITH WEATHERHEAD OR i�iYc �S EQUIVALENT. i! TOP OF FINISHED FLOOR j m 1 tik Quantity NEW A.C. UNIT }'{ cingula r Application TYPE GR TYPE "SPECIAL" SEAL & CAULK TYPE PT site WITH 2 HOLE PLASTIC AROUND PULL BOX BY CLAMP W/ STAINLESS TYPE GL LUG STEEL SCREWS AT 24" O.C. GENERAL CONTRACTOR TOP OF GRAVEL tw kr. F-ai, I.,,, direct Burial, Rodent Resistant UHO Mwb I F..day Drive s";a aoR rpo rFINISHED GRADE 4" DIA. PVC CONDUIT TYPE HS TYPE SS It TYPE "SPECIAL" SCHED 40 SUPPLY AND INSTALLED BY CONTRACTOR -1 circuits to shelter/site) xcTYPE VS fastened to conduit) TYPE HA TYPE XA 25 Pair, 21 awg CAT 5 Cable, FINISHED GRADE direct Burial, Rodent Resistant 25P Exchange Cable PE -39, CAT 5 Solid/ C -TYPE COPPER COMPRESSION TAP CONNECTS Filled Core/CACSP, Rodent Resistant ;.; TWO COPPER CONDUCTORS TOGETHER COMPRESSED WITH A HYDRAULIC CRIMP TOOL. MANUFACTURER: HARGER, INC. SERIES, CT. CADWELD DETAILS 4 1 TELCO ENTRY DETAIL QUABBIN P/N 9788 DETAIL 4 CINGULAR SHELTER ON TURN DOWN SLAB SHEET E-2 POWER UNIT WITH DETAIL 5 INTEGRAL MAINS, ITEM 5 TRANSFER SWITCH, TVSS, AND PANELBOARD (SUPPLIED W/ SHELTER) TRANSFER SWITCH TELCO BOARD NORMAL CIRCUIT BREAKER RATED ®400 AMPS �T T U"11 L!"I'Y DIAGRAM urawmg rypt ' or "" tamuy PREFAB FODI��IT I SHELTER BUILDING � TELCO BOARD ILII/// Imo_ CONDUIT IN THE SHELTER I NEEDS ?0 BE SEALED 7/ 11771/ ON BOTH ENDS AFTER TELCO LINE IS INSTALLED. CONDUIT AT TELCO END SHALL BE WEATHER SEALED WITH WEATHERHEAD OR i�iYc �S EQUIVALENT. i! TOP OF FINISHED FLOOR j m 1 tik LOOP LINE OF FOUNDATION EDGE OF FOUNDATION 1 3 1 NOT USED 2 1 HVAC GROUNDING Quantity NEW A.C. UNIT }'{ cingula r Application WIRELESS GROUND WARE Anixter Catalog Number and Description 1/2" DIAM. PVC CONDUIT site WITH 2 HOLE PLASTIC CLAMP W/ STAINLESS WIt STEEL SCREWS AT 24" O.C. I TOP OF GRAVEL tw kr. F-ai, I.,,, direct Burial, Rodent Resistant UHO Mwb I F..day Drive s";a aoR rpo rFINISHED GRADE Z., VA 201% USA LOOP LINE OF FOUNDATION EDGE OF FOUNDATION 1 3 1 NOT USED 2 1 HVAC GROUNDING SHEET E-2 DETAIL 5 ITEM 2 SHEET E-2 DETAIL 5 PANEL SWITCH ITEM 1 3 /-VERIZON CELL PANEL PB 2 1 SITE CABINET 4"x4"x36" HIGH PRESSURE TREATED WITH A 120/240 VOLT O RATED, 2 POLE WITH SOLID EMERGENCY CIRCUIT UTILITY COMPANY NEUTRAL 30 AMP WEATHERPROOF BREAKER RATED ® 400 DISTRIBUTION BACKBOARD DISCONNECT SWITCH (WIRING PER AMPS VERIZON SPECIFICATIONS) SHEET E-2 SHEET E-2 w Q DETAIL 5 DETAIL 5 ELECTRIC SERVICE TROUGH ITEM 7 ITEM 3 VGENERATOR E RECEPTACLE (WP) PROPOSED QUAZITE HANDHOLE UTILITY COMPANY (3) 350 KCMIL + #4G WITH FLUSH COVER D TRANSFORMER IN 400 AMP WIRING w TRANSITION TO GALVANIZED RMC 6 ABOVE GRADE I I 5 L (TYPICAL) _ U —E E E E E E E E E E E E JI T T T 7 T T T T T T 120/240V 10 3W 400A FEEDER IN (2) 4" CONDUIT rDynatekl DYNATEK 4883 I PROJ. NO.: DRAWN BY: J.E.D. CHECKEDBY: D.C.B. SUBMITTALS 5 6/23/05 95% 4 5/19/05 90% 3 1/10/05 95% 2 1/20/05 907 1 11/19/04 95% 0 10/13/04 90% THIS DOCUMENT IS THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED WORK OF CINGULAR WIRELESS. ANY DUPUCATION OR USE WITHOUT EXPRESS 5 WRITTEN CONSENT IS STRICTLY PROHIBITED. DUPLICATION AND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR LAWFULLY AUTHORIZED REGULATORY AND ADMINISTRATIVE FUNCTIONS IS SPECIFICALLY ALLOWED. DRAWING NOTES: 1. UTILITY COMPANY FURNISHED METER, CONTRACTOR PROVIDED AND INSTALLED C/T CABINET WITH METER CAN. COORDINATE EXACT CONFIGURATION OF SERVICE ENTRANCE EQUIPMENT WITH THE UTILITY COMPANY IN THE FIELD PRIOR TO INSTALLATION. MOUNT METER ON NEW BACKBOARD FACING FENCE. PROVIDED 2 1/2" RIGID CONDUIT BETWEEN C/T CABINET AND EXISTING ELECTRIC SERVICE TROUGH FOR EXTENSION OF UTILITY COMPANY SERVICE CABLES (BY UTILITY COMPANY). PROVIDE PHENOLIC NAMEPLATE READING "CINGULAR WIRELESS". 2. PROVIDE 240V SERVICE ENTRANCE RATED, 2 POLE WITH S/N 400 AMP WEATHERPROOF DISCONNECT FUSED ® 300 AMPS (CLASS RKI FUSES). PROVIDE PHENOLIC NAMEPLATE READING "CINGULAR MAIN DISCONNECT". 3. EXTEND ONE (1) - 2 1/2" EMPTY RIGID CONDUIT BETWEEN C/T CABINET AND NEW CINGULAR DISCONNECT FOR EXTENSION OF UTILITY SERVICE CABLES (BY UTILITY COMPANY). COORDINATE EXACT SERVICE EQUIPMENT CONFIGURATION WITH UTILITY COMPANY IN THE FIELD. 4. EXISTING ELECTRIC DISTRIBUTION EQUIPMENT PROVIDED WITH SHELTER. 5. EXTEND ONE (1) - 4" PVC CONDUIT WITH (2) - 25 PAIR, CATS CABLE AND PULLSTRINGS BELOW GRADE FROM CINGULAR WIRELESS EQUIPMENT SHELTER TO EXISTING TELEPHONE HAND HOLE. COORDINATE FINAL TERMINATIONS WITH CINGULAR WIRELESS/TELEPHONE COMPANY REPRESENTATIVES IN THE FIELD. 6. PROVIDE 3#350 KCMIL + #4 GRD - 2 1/2" PVC CDT. 7. CONTRACTOR SHALL CONTACT MS. UTILITY 72 HOURS PRIOR TO TRENCHING. ALL TRENCHING WITHIN (5) FEET OF EXISTING UNDERGROUND UTILITIES SHALL BE HAND DUG. RIDINGS HILL #1724 1009 GERMANY ROAD STEPHENS CITY, VA 22655 GROUNDING AND ELECTRICAL DETAILS PROJECT: 1724 SHEE'T: DATE: 10/13/04 E - 3 SCALE: NO SCALE Quantity Application of runs per Description Anixter Catalog Number and Description site 4 Pair, 24 awg CAT 5 Cable, F-04P24BPN-5E, Superior C 04-601-55, 24 - direct Burial, Rodent Resistant 4P Outside Plant Cable 5E, DBL JCKT 1 Filled Cable, Burial Rodent Resist Telco Demarcation existing (underground Pull String (waxed and securely Future additions circuits to shelter/site) I fastened to conduit) 25 Pair, 21 awg CAT 5 Cable, E-002524AFO-5, Superior C 04 -097 -37,24 - direct Burial, Rodent Resistant 25P Exchange Cable PE -39, CAT 5 Solid/ 2 Filled Core/CACSP, Rodent Resistant SHEET E-2 DETAIL 5 ITEM 2 SHEET E-2 DETAIL 5 PANEL SWITCH ITEM 1 3 /-VERIZON CELL PANEL PB 2 1 SITE CABINET 4"x4"x36" HIGH PRESSURE TREATED WITH A 120/240 VOLT O RATED, 2 POLE WITH SOLID EMERGENCY CIRCUIT UTILITY COMPANY NEUTRAL 30 AMP WEATHERPROOF BREAKER RATED ® 400 DISTRIBUTION BACKBOARD DISCONNECT SWITCH (WIRING PER AMPS VERIZON SPECIFICATIONS) SHEET E-2 SHEET E-2 w Q DETAIL 5 DETAIL 5 ELECTRIC SERVICE TROUGH ITEM 7 ITEM 3 VGENERATOR E RECEPTACLE (WP) PROPOSED QUAZITE HANDHOLE UTILITY COMPANY (3) 350 KCMIL + #4G WITH FLUSH COVER D TRANSFORMER IN 400 AMP WIRING w TRANSITION TO GALVANIZED RMC 6 ABOVE GRADE I I 5 L (TYPICAL) _ U —E E E E E E E E E E E E JI T T T 7 T T T T T T 120/240V 10 3W 400A FEEDER IN (2) 4" CONDUIT rDynatekl DYNATEK 4883 I PROJ. NO.: DRAWN BY: J.E.D. CHECKEDBY: D.C.B. SUBMITTALS 5 6/23/05 95% 4 5/19/05 90% 3 1/10/05 95% 2 1/20/05 907 1 11/19/04 95% 0 10/13/04 90% THIS DOCUMENT IS THE CREATION, DESIGN, PROPERTY AND COPYRIGHTED WORK OF CINGULAR WIRELESS. ANY DUPUCATION OR USE WITHOUT EXPRESS 5 WRITTEN CONSENT IS STRICTLY PROHIBITED. DUPLICATION AND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR LAWFULLY AUTHORIZED REGULATORY AND ADMINISTRATIVE FUNCTIONS IS SPECIFICALLY ALLOWED. DRAWING NOTES: 1. UTILITY COMPANY FURNISHED METER, CONTRACTOR PROVIDED AND INSTALLED C/T CABINET WITH METER CAN. COORDINATE EXACT CONFIGURATION OF SERVICE ENTRANCE EQUIPMENT WITH THE UTILITY COMPANY IN THE FIELD PRIOR TO INSTALLATION. MOUNT METER ON NEW BACKBOARD FACING FENCE. PROVIDED 2 1/2" RIGID CONDUIT BETWEEN C/T CABINET AND EXISTING ELECTRIC SERVICE TROUGH FOR EXTENSION OF UTILITY COMPANY SERVICE CABLES (BY UTILITY COMPANY). PROVIDE PHENOLIC NAMEPLATE READING "CINGULAR WIRELESS". 2. PROVIDE 240V SERVICE ENTRANCE RATED, 2 POLE WITH S/N 400 AMP WEATHERPROOF DISCONNECT FUSED ® 300 AMPS (CLASS RKI FUSES). PROVIDE PHENOLIC NAMEPLATE READING "CINGULAR MAIN DISCONNECT". 3. EXTEND ONE (1) - 2 1/2" EMPTY RIGID CONDUIT BETWEEN C/T CABINET AND NEW CINGULAR DISCONNECT FOR EXTENSION OF UTILITY SERVICE CABLES (BY UTILITY COMPANY). COORDINATE EXACT SERVICE EQUIPMENT CONFIGURATION WITH UTILITY COMPANY IN THE FIELD. 4. EXISTING ELECTRIC DISTRIBUTION EQUIPMENT PROVIDED WITH SHELTER. 5. EXTEND ONE (1) - 4" PVC CONDUIT WITH (2) - 25 PAIR, CATS CABLE AND PULLSTRINGS BELOW GRADE FROM CINGULAR WIRELESS EQUIPMENT SHELTER TO EXISTING TELEPHONE HAND HOLE. COORDINATE FINAL TERMINATIONS WITH CINGULAR WIRELESS/TELEPHONE COMPANY REPRESENTATIVES IN THE FIELD. 6. PROVIDE 3#350 KCMIL + #4 GRD - 2 1/2" PVC CDT. 7. CONTRACTOR SHALL CONTACT MS. UTILITY 72 HOURS PRIOR TO TRENCHING. ALL TRENCHING WITHIN (5) FEET OF EXISTING UNDERGROUND UTILITIES SHALL BE HAND DUG. RIDINGS HILL #1724 1009 GERMANY ROAD STEPHENS CITY, VA 22655 GROUNDING AND ELECTRICAL DETAILS PROJECT: 1724 SHEE'T: DATE: 10/13/04 E - 3 SCALE: NO SCALE KEYNOTESD 1. POWER SERVICES REQUIREMENTS SHALL BE COMMERCIAL AC NOMINAL 240/120 VOLT, 1 PHASE, 3 WIRE PROVIDED FOR LOCAL POWER COMPANY. COORDINATE WITH CONSTRUCTION MANAGER. 2. CONTRACTOR WILL ALSO CONTACT LOCAL TELEPHONE COMPANY FOR PROVISIONS OF 'T1" SERVICE LINE TO TERMINATE AT THE TELCO CABINET. 3. LOCAL POWER COMPANY SHALL INSTALL METER. 4. POWER AND TELCO CONDUIT LINES AND CABLE SIZING, SHALL MEET ALL MINIMUM NEC REQUIREMENTS. 5. ALL TELCO CONDUIT LINES SHALL BE 4" CONDUIT UNLESS OTHERWISE INDICATED. 6. GROUND SOURCE SHALL BE GROUND RODS. USE #2 AWG CONDUCTOR. 7. ALL CONDUIT SHALL BE AS DEPICTED ON DRAWING. WHERE RIGID METAL CONDUIT(RMC) IS USED, THREADS SHALL HAVE "SCOTCHCOAT" APPLIED. ONE LINE DIAGRAM TO POWER ORIGIN QUANITY EACH APPROX. LENGTH FEET ORDERED APPROX. TOTAL FEET ORDERED RESPONSIBLE PARTY TO "T1" DESCRIPTION 1 3 44 METER TELEPHONE SERVICE N/A I CINGULAR (CONTRACTOR AP14/17-880/1940/088D/ADT/XXP INSTALLED) M 1 5/8" COMMSCOPE Z W Z Z W Z 1300 FT. 2 W Z �J Z W ~ 1 NEMA TYPE 1, DISCONNECT 2" CONDUIT CONDUIT 2 W Z I SQUARE D #HU363RB OR SQUARE W/PULL STRING N/A N/A CONSTRUCTION FEM CONNECTOR I GROUND 1/2" 4 FT. COMMSCOPE I N/A N/A CONSTRUCTION JUMPER CABLE I I I I _ _ PROPOSED KIT (TYP) 1 CINGULAR 5 TELCO FACILITY 1 N/A N/A (C OR ENCLOSURE G I I G I 5 6 I I 1/2" COMMSCOPE i I I rJ ( G I ��I 2" CONDUIT ( 1 I COAX CABLE W/PULL STRING I I I I 4 O6 77 ( I 400A CIRCUIT SGB N/A o CONSTRUCTION BREAKER 00 TELCO #2 AWG TINNED #2 AWG TINNED 8 BACKBOARD If AWG TINNED N/A 48.0' I LOAD CENTER I BCW TO MGB I PRIMARY RADIO I POWER CABINET BCW TO MGB CABINET KEYNOTESD 1. POWER SERVICES REQUIREMENTS SHALL BE COMMERCIAL AC NOMINAL 240/120 VOLT, 1 PHASE, 3 WIRE PROVIDED FOR LOCAL POWER COMPANY. COORDINATE WITH CONSTRUCTION MANAGER. 2. CONTRACTOR WILL ALSO CONTACT LOCAL TELEPHONE COMPANY FOR PROVISIONS OF 'T1" SERVICE LINE TO TERMINATE AT THE TELCO CABINET. 3. LOCAL POWER COMPANY SHALL INSTALL METER. 4. POWER AND TELCO CONDUIT LINES AND CABLE SIZING, SHALL MEET ALL MINIMUM NEC REQUIREMENTS. 5. ALL TELCO CONDUIT LINES SHALL BE 4" CONDUIT UNLESS OTHERWISE INDICATED. 6. GROUND SOURCE SHALL BE GROUND RODS. USE #2 AWG CONDUCTOR. 7. ALL CONDUIT SHALL BE AS DEPICTED ON DRAWING. WHERE RIGID METAL CONDUIT(RMC) IS USED, THREADS SHALL HAVE "SCOTCHCOAT" APPLIED. ONE LINE DIAGRAM SITE NO: 1724 RIDINGS HILL QUANITY EACH APPROX. LENGTH FEET ORDERED APPROX. TOTAL FEET ORDERED RESPONSIBLE PARTY ITEM DESCRIPTION 1 ANTENNA 6 N/A N/A CINGULAR (CONTRACTOR AP14/17-880/1940/088D/ADT/XXP INSTALLED) 2 1 5/8" COMMSCOPE Z W Z Z W Z 1300 FT. 2 W Z Z W Z Z W ~ 2 W 2 Z W Z 2 W Z 3 ANTENNA 12 N/A N/A CONSTRUCTION FEM CONNECTOR GROUND 1/2" 4 FT. COMMSCOPE 6 N/A N/A CONSTRUCTION JUMPER CABLE CONTRACTOR KIT (TYP) CINGULAR 5 ANTENNA, GPS (TBD) 1 N/A N/A (C OR G G G 6 1/2" COMMSCOPE 1 40 FT. G G COAX CABLE o Oo 0000.. 3GB lboToo60000 7 1/2" COMMSCOPE SGB N/A o CONSTRUCTION 00 0000 #2 AWG TINNED #2 AWG TINNED 8 1/2" 8 FT. BOTTOM If AWG TINNED N/A 48.0' CONCONTRACTOR BCW TO MGB BCW TO MGB BCW TO MGB BUSS BAR LOCATED AT BOTTOW OF TOWER z � z a� a� r SECTOR GROUND BARS SHALL BE MOUNTED TO THE TOWER AT THE ANTENNA MOUNTING ASSEMBLY LOCATIONS AND SHALL BE EQUIPPED WITH NON -INSULATING HARDWARE COAXIAL SIGNAL CABLES TO SHELTER, GROUNDED WITH MANUFACTURER'S GROUNDING KITS TO SGB AND MGB EQUIPMENT SHELTER ONLY 6 COAXIAL A/C CABLES SHOWN :DIRIB. SAFETY FOR CLARITY POLYPHASER NELSWITCH GND BAR N o =G ®G Gr --SHELTER GROUND G G G G G G G G G G MGB 00 0 00000 00 000 000 o p * GPS RUNS OVER 50' SHALL REQUIRE ADDITIONAL G LOCATED ON EQUIPMENT L q TO COAX CABLE GROUNDING. t SHELTER BENEATH COAX TRAY, IF REQUIRED G ENTRY PORT TYPICAL GROUNDING RISER DIAGRAM SEE SITE SPECIFIC DRAWINGS FOR REQUIRED EQUIPMENT AND LOCATIONS TELCO PANEL —r G i T GATE I F GATE JUMPER #2 AWG WELDING CABLE #2 AWG TINNED SOLID COPPER WIRE -EXTENDED TO OPPOSITE FENCE POST FENCE GROUNDING DETAIL -#2 AWG TO GROUND RING 10' x 5/8" GROUND BAR FENCE POST X* cingula r WIRELESS EXOTHERMICALLY WELD_ TO FENCE POST W� = \Guekss F�cJ,ua, Inc. 1140 Mid—I F -6y Dmi e Swire 200 It—,s, VA 20190 USA BILL OF MATERIALS SITE NO: 1724 RIDINGS HILL QUANITY EACH APPROX. LENGTH FEET ORDERED APPROX. TOTAL FEET ORDERED RESPONSIBLE PARTY ITEM DESCRIPTION 1 ANTENNA 6 N/A N/A CINGULAR (CONTRACTOR AP14/17-880/1940/088D/ADT/XXP INSTALLED) 2 1 5/8" COMMSCOPE 6 VARIES 1300 FT. CONSTRUCTION COAX CABLE CONTRACTOR 3 COMMSCOPE 12 N/A N/A CONSTRUCTION FEM CONNECTOR 4 1/2" 4 FT. COMMSCOPE 6 N/A N/A CONSTRUCTION JUMPER CABLE CONTRACTOR CINGULAR 5 ANTENNA, GPS (TBD) 1 N/A N/A (C OR INSTALLED) 6 1/2" COMMSCOPE 1 40 FT. 40 FT. CONSTRUCTION COAX CABLE 7 1/2" COMMSCOPE 2 N/A N/A CONSTRUCTION CONNECTOR CONTRACTOR 8 1/2" 8 FT. BOTTOM 6 N/A 48.0' CONCONTRACTOR COMSCOPE JUMPERS RF BILL OF MATERIAL COAX CABLE 1/4" ALL THREAD, LENGTH AS REQUIRED (TYP OF 2) HUBER & SUHNER PART #3409.41.0048 S 1/2" JUMPER TO EQUIPMENT HATCHPLATE 0 ARRESTOR TRAPEZE KIT (MTS WIRELESS PART # AT—K306—U) PROVIDE c 2—HOLE LUG (NP) MOUNT CELL REFERENCE GROUND BAR (CRGB) CENTERED BELOW HATCHPLATE ---?TO HALO (4) NOTES: 1. VIEW IS FROM INSIDE OF SHELTER. 2. MTS KIT INCLUDES: TO GROUND RING - COPPER TRAPEZE TREADED ROD - CEILING MOUNTING BRACKETS POLYPHASER MOUNTING SECTION 0 0 INTERIOR (HALO) GROUND RING �rDynatekl DYNATEK 4883 I PROJ. NO.: DRAWN BY: J.E.D. CHECKED BY: D.C.B. SUBMITTALS 5 6/23/05 95% 4 5/19/05 90% 3 1/10/05 95% 2 1/20/05 907. 1 11/19/04 955F 0 10/13/04 90% THIS DOCUMENT IS THE CREATION. DESIGN. PROPERTY AND COPYRIGHTED WORK OF CINGULAR WIRELESS. ANY DUPLICATION OR USE WITHOUT EXPRESS 2 WRITTEN CONSENT IS STRICTLY PROHIBITED. DUPLICATION AND USE BY GOVERNMENT AGENCIES FOR THE PURPOSES OF CONDUCTING THEIR LAWFULLY AUTHORIZED REGULATORY AND ADMINISTRATIVE FUNCTIONS IS SPECIFICALLY ALLOWED. ANON -DIRECTIONAL SPLICE PROVIDE MOLDED POLYESTER FIBER GLASS INSULATOR AS MANUFACTURED BY NEWTON (TYP OF 2) POLYPHASER MAIN GROUND, COPPER CONDUCTOR TO GROUNDING ELECTRODE (BURIED GROUND RING, BUILDING WATER SERVICE, ETC.) RIDINGS HILL #1724 1009 GERMANY ROAD STEPHENS CITY, VA 22655 ELECTRICAL AND GROUNDING DETAILS PROJECT: 1724 SI-IEET: DATE: 10/13/04 E _ 4 SCALE: NO SCALE