HomeMy WebLinkAbout06-07 Comments (2)TABLE OF CONTENTS
Project Vicinity Map 1
S.CS. Generalized Soil Map 2
FEVLA Flood Hazard Map 3
Narrative
Scope of Work and Basis of Computations 1
Conclusions and Recommendations 1
Basis of Design 1
Appendices
A Culvert Computations
1R -55 Computer Model A -4
HY8 Calculations A -8
13 Drainage Area Map
1
1
1
11
1
1'
1
1�
1
1
1
1
Patton Harris Rust St Associates
Engineers. Surveyors. Planners Landscape Architects.
P RA
117 East Piccadilly Street
Winchester. VA 22601 5002
T 540.667.2139
F 540.665.0493
PROJECT VICINTY MAP
BROOKE ROAD PHASE 2
JOHNSON DEVELOPMENT ASSOCIATES, INC.
BROOKE ROAD
FREDERICK COUNTY, VIRGINIA
SCALE: APPROX. 1" 1000'
DATE: 01/16/08
DRAWN BY: KLM
PROJECT 15761 -1 -0
i
1
SOILS CHART
MAP UNIT SYMBOL
MAP UNIT NAME
14B
14C
16B
I 6C
17C
17E
29
32B
33C
35
FREDERICK— POPLIMENTO LOAMS
2 TO 7% SLOPES
FREDERICK POPUMENTO LOAMS
7 TO 15% SLOPES
FREDERICK POPUMENTO LOAMS
VERY ROCKY, 2 TO 7% SLOPES
FREDERICK POPLIMENTO LOAMS
VERY ROCKY, 7 TO 15% SLOPES
FREDERICK— POPLIMENTO ROCK OUTCROP COMPLEX
VERY ROCKY, 2 TO 15% SLOPES
FREDERICK POPUMENTO ROCK OUTCROP COMPLEX
VERY ROCKY, 15 TO 4510 SLOPES
MASSNJETTA LOAM
OAKLET SILT LOAM
2 TO 7% PERCENT SLOPES
OPEOUON— CHILHOWIE SILTY CLAYS
VERY ROCKY, 3 TO 1510 PERCENT SLOPES
PAGEBROOK SILTY CLAY LOAM
Patton Harris Rust 8 Associates,pc
Engineers. Surveyors. Planners. Landscape Architects.
-nom
117 Eu,t Piccadilly Street
Winchester. VA 22601 -5002
T 540.667.2139
F 540665.0493
SOILS MAP
BROOKE ROAD PHASE 2
JOHNSON DEVELOPMENT ASSOCIATES. INC.
BROOKE ROAD
FREDERICK COUNTY, VIRGINIA
SCALE: APPROX. 1" 1000'
DATE: 01/16/08
DRAWN BY: KLM
PROJECT 15761 -1 -0
1
It A'
TOAD
LIMIT OF
DETAILED STUDY
ZONE B
ZONE A10
7/17/78
PRIVATE ROAD 699
ZONE B
e
FLOOD INSURANCE RA
COMMUNITY PANEL NO
510063 01058
510063 0115B
ZONE A3
7 /17/78
Il
I,
MAP
IBERS
Patton Harris Rust Associates,pc
Engineers. Surveyors. Plonne's. Landscape Architects.
P RA
117 Eat Picmtlllly Street
Wncte,le. VA 22601 -5002
T 540.667.2139
F 540.965 0497
FEMA FLOODPLAIN MAP
BROOKE ROAD PHASE 2
JOHNSON DEVELOPMENT ASSOCIATES, INC.
BROOKE ROAD
FREDERICK COUNTY, VIRGINIA
SCALE: APPROX. 1" 1000'
DATE: 01/16/08
DRAWN BY: KLM
PROJECT 15761 -1 -0
1
1
1
1
1�
Scope of Work:
The purpose of this report is to present the results of computations and to design storm
water conveyance structures required to extend the existing box culvert Park Center
Drive crossing for Brooke Road Phase 2 site. The project is located in the Stonewall
District, Tax Map 54, Frederick County, Virginia. The facilities described in this report
were designed to comply with the requirements of Frederick County, Virginia and the
Virginia Department of Transportation.
Basis of Computations:
This report uses the TR -55 and the Snyder Method Procedure as outlined in the Virginia
Department of Transportation Drainage Manual to compute peak runoff rates from the
drainage areas. The HY8 Culvert Analysis program was then used to automate the
culvert design methods described in FHWA publications Highway Hydrology, Hydraulic
Design Series No. 2 (HDS -2); Hydraulic Design of Highway Culverts, Hydraulic Design
Series No. 5 (HDS -5); and Hydraulic Design of Energy Dissipators for Culverts and
Channels and Hydraulic Engineering Circular No. 14 (HEC -14).
Conclusions and Recommendation:
The design of the storm drainage facilities for this project was influenced by the existing
topography, existing land uses and cover conditions and drainage patterns. We offer the
following conclusions and recommendations for the storm water conveyance structures
for this project:
The existing three (3) 9.5' x 4' box culverts under Park Center Drive are adequate
to handle the peak flows from the 10 year and 25 year storm events without over
topping the road. The box culverts will need to be extended approximately twelve
(12) feet to accommodate the new access roadway.
Basis of Design:
NARRATIVE
This project site lies on the south side of Route 37 and the west side of U.S. Route 81 in
the Fort Collier Industrial Park and more specifically at the end of the existing Brooke
Road Phase 1 and Park Center Drive. Runoff generally flows eastward towards
U.S.Route 81 and into the existing Redbud Run. The Soil Survey of Frederick County
indicates that the soil on the site is predominately Frederick Poplimento loams
(Hydrogeologic Soil Group B). These soils have moderate infiltration rates when
thoroughly wetted and consist of moderately deep to deep, moderately well to well
drained soils with moderately fine to moderately coarse textures. See page 2 for soils
map.
Revised August 16, 2008
Area
RCN
Tc
Area
2 -Year
5 -Year
10 -Year
25 -Year
50 -year
100 -year
2
88
0.87
245
271cfs
406cfs
504cfs
617cfs
761cfs
833cfs
3
88
0.87
286
316cfs
474cfs
588cfs
720cfs
888cfs
972cfs
1�
1!
1
1
1
1
1
1
1
1
1
1
1�
1
1
i
1
Peak Runoff Computations were computed for the required storm events using
SCS TR -55 and the Snyder Method. The size of the drainage areas were
delineated and are shown on the included drainage area map. A =off coefficient
was computed assuming an industrial land use and a time of concentration was
computed.
See attached calculations and Appendices for Drainage Area 1 using the Snyder
Method.
The storm drainage facilities were analyzed and designed using HY8 and
inputting the site data, culvert information and peak runoff discharges, All
proposed culverts were designed to safely pass the 10 year storm event without
overtopping the road surface. All calculations are included.
Revised August 16, 2008
APPENDICES
A. CULVERT COMPUTATIONS
u]a >ori NN71-1in v)
z
SITE DATA
CULVERT
SHAPE,
MATERIAL,
INLET
INLET
ELEV.
(ft)
669.53
669.69
669.72
OUTLET
ELEV
(ft)
669.52
669.01
669.22
CULVERT
LENGTH
(ft)
58.90
62.50
66.20
BARRELS
SHAPE
MATERIAL
1 RCB
1 RCB
1 RCB
SPAN
(ft)
9.50
9.50
9.50
RISE
(ft)
4.00
4.00
4.00
MANNING
n
.012
.012
.012
INLET
TYPE
CONVENTIONAL
CONVENTIONAL
CONVENTIONAL
CURRENT DATE: 06 -24 -2008
JRRENT TIME: 14:57:08
1
1
1
1
1 SUMMARY OF CULVERT FLOWS (cfs) FILE: FTBOX DATE: 06 -24 -2008
ELEV (ft) TOTAL 1 2 3 4 5 6 ROADWAY ITR
I 671.53 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00 0
671.61 77.0 34.3 12.7 0.1 0.0 0.0 0.0 0.00 11
671.64 154.0 41.1 78.6 17.4 0.0 0.0 0.0 0.00 14
I 671.78 231.0 61.3 86.8 84.7 0.0 0.0 0.0 0.00 6
672.12 308.0 95.1 107.7 105.3 0.0 0.0 0.0 0.00 3
672.47 385.0 122.9 132.0 129.4 0.0 0.0 0.0 0.00 2
I 672.84
673.18 462.0 148.3 158.3 155.5 0.0 0.0 0.0 0.00 3
539.0 172.2 184.2 181.4 0.0 0.0 0.0 0.00 2
673.53 616.0 197.3 210.1 207.4 0.0 0.0 0.0 0.00 2
673.69 651.5 209.3 222.1 219.4 0.0 0.0 0.0 0.00 2
I 674.22 770.0 251.8 261.0 258.5 0.0 0.0 0.0 0.00 2
676.50 1191.8 402.4 395.6 393.8 0.0 0.0 0.0 OVERTOPPING
1
1
1
1
1
HEAD HEAD TOTAL FLOW FLOW
ELEV (ft) ERROR (ft) FLOW (cfs) ERROR (cfs) ERROR
671.53 0.000 0.00 0.00 0.00
671.61 0.000 77.00 29.98 38.94
671.64 0.000 154.00 16.90 10.97
671.78 0.003 231.00 -1.81 -0.78
672.12 0.001 308.00 -0.17 -0.06
672.47 -0.003 385.00 0.66 0.17
672.84 0.000 462.00 -0.07 -0.02
673.18 -0.005 539.00 1.20 0.22
673.53 -0.006 616.00 1.26 0.20
673.69 -0.003 651.50 0.78 0.12
674.22 0.006 770.00 -1.27 -0.16
1
FHWA CULVERT ANALYSIS
HY -8, VERSION 6.1
1 <1> TOLERANCE (ft) 0.010 <2> TOLERANCE 1.000
1
FILE DATE: 06 -24 -2008
FILE NAME: FTBOX
SUMMARY OF ITERATIVE SOLUTION ERRORS FILE: FTBOX DATE: 06 -24 -2008
l
"CURRENT DATE: 06 -24 -2008
CURRENT TIME: 14:57:08
1 PERFORMANCE CURVE FOR CULVERT 1 1( 9.50 (ft) BY
DIS- HEAD- INLET OUTLET
1 I
1 CHARGE WATER CONTROL CONTROL FLOW NORMAL
FLOW ELEV. DEPTH DEPTH TYPE DEPTH
(cfs) (ft) (ft) (ft) <F4> (ft)
0.00
34.25
41.07
I 61.29
95.10
122.91
148.33
172.19
197.29
209.26
251.75
1
,I SITE DATA CULVERT INVERT
INLET STATION 0.00 ft
INLET ELEVATION 669.53 ft
OUTLET STATION 58.90 ft
OUTLET ELEVATION 669.52 ft
NUMBER OF BARRELS 1
SLOPE (V /H) 0.0002
1 CULVERT LENGTH ALONG SLOPE 58.90 ft
BARREL SHAPE BOX
BARREL SPAN 9.50 ft
BARREL RISE 4.00 ft
11
1
1
671.53
671.61
671.64
671.77
672.11
672.47
672.84
673.18
673.53
673.69
674.22
0.00 2.00 0 -NF 0.00
1.14 2.08 3 -Mlt 1.74
1.28 2.11 3 -Mlt 1.97
1.67 2.24 3 -M2t 2.60
2.25 2.58 3 -M2t 3.55
2.68 2.94 3 -M2t 4.00
3.04 3.31 3 -M2t 4.00
3.36 3.65 2 -M2c 4.00
3.69 4.00 2 -M2c 4.00
3.84 4.16 2 -M2c 4.00
4.42 4.69 2 -M2c 4.00
CULVERT DATA SUMMARY
BARREL MATERIAL
BARREL MANNING'S n
INLET TYPE
INLET EDGE AND WALL
INLET DEPRESSION
CRIT. OUTLET TW
DEPTH DEPTH DEPTH
(ft) (ft) (ft)
0.00
0.74
0.84
1.09
1.46
1.74
1.97
2.17
2.38
2.48
2.80
0.00
2.01
2.01
2.01
2.01
2.01
2.01
2.17
2.38
2.48
2.80
CONCRETE
0.012
CONVENTIONAL
SQUARE EDGE (30 -75 DEG. FLARE)
NONE
4.00 (ft)) RCB
2.01
2.01
2.01
2.01
2.01
2.01
2.01
2.01
2.01
2.01
2.01
2
FILE DATE: 06 -24 -2008
FILE NAME: FTBOX
OUTLET TW
VEL. VEL.
(fps) (fps)
0.00 0.00
1.79 0.00
2.15 0.00
3.21 0.00
4.98 0.00
6.44 0.00
7.77 0.00
8.34 0.00
8.73 0.00
8.90 0.00
9.46 0.00
El. inlet face invert 669.53 ft El. outlet invert 669.52 ft
El. inlet throat invert 0.00 ft El. inlet crest 0.00 ft
1
1
1
CURRENT DATE: 06 -24 -2008
CURRENT TIME: 14:57:08
PERFORMANCE CURVE FOR CULVERT 2 1( 9.50 (ft) BY
DIS- HEAD- INLET OUTLET
CHARGE WATER CONTROL CONTROL FLOW NORMAL
FLOW ELEV. DEPTH DEPTH TYPE DEPTH
(cfs) (ft) (ft) (ft) <F4> (ft)
1 0.00 671.53 0.00 1.84 0 -NF 0.00
12.71 671.62 0.58 1.93 3 -Mlt 0.20
I I 671.65 1.96 1.96 1 -32n 0.81
1 86.85 671.79 2.10 2.10 1 -32n 0.86
107.72 672.12 2.43 2.43 1 -92n 0.99
131.99 672.48 2.79 2.79 1 -S2n 1.13
11
158.25 672.84 3.15 3.15 1 -82n 1.28
184.18 673.18 3.49 3.49 1 -82n 1.41
210.10 673.52 3.83 3.83 1 -S2n 1.54
I 222.11 673.68 3.99 3.99 1 -S2n 1.60
261.05 674.22 4.53 4.53 5 -S2n 1.78
0.00
0.38
1.29
1.38
1.59
1.82
2.05
2.27
2.48
2.58
2.87
El. inlet face invert 669.69 ft El. outlet invert 669.01 ft
El. inlet throat invert 0.00 ft
El. inlet crest 0.00 ft
1 SITE DATA CULVERT INVERT
INLET STATION 0.00 ft
1
1
1�
1
1
1'
1
1!!
INLET ELEVATION
OUTLET STATION
OUTLET ELEVATION
NUMBER OF BARRELS
SLOPE (V /H)
CULVERT LENGTH ALONG SLOPE
CULVERT DATA SUMMARY
BARREL SHAPE
BARREL SPAN
BARREL RISE
BARREL MATERIAL
BARREL MANNING'S n
INLET TYPE
INLET EDGE AND WALL
INLET DEPRESSION
CRIT. OUTLET TW OUTLET TW
DEPTH DEPTH DEPTH VEL. VEL.
(ft) (ft) (ft) (fps) (fps)
669.69 ft
62.50 ft
669.01 ft
1
0.0109
62.50 ft
0.00
2.52
0.89
0.96
1.13
1.31
1.49
1.67
1.85
1.93
2.17
BOX
9.50 ft
4.00 ft
CONCRETE
0.012
CONVENTIONAL
SQUARE EDGE (30 -75 DEG. FLARE)
NONE
3
FILE DATE: 06 -24 -2008
FILE NAME: FTBOX
4.00 (ft)) RCB
2.52 0.00
2.52 0.53
2.52 9.31
2.52 9.55
2.52 10.04
2.52 10.60
2.52 11.15
2.52 11.59
2.52 11.94
2.52 12.14
2.52 12.67
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
1
"CURRENT DATE: 06 -24 -2008
CURRENT TIME: 14:57:08
1 1 PERFORMANCE CURVE FOR CULVERT 3 1( 9.50 (ft) BY 4.00 (ft)) ROB
1
1
0.00
0.07
1 17.44
84.67
105.34
129.44
II 155.49
181.43
207.35
I 219.35
258.47
1
SITE DATA CULVERT INVERT
INLET STATION 0.00 ft
INLET ELEVATION 669.72 ft
OUTLET STATION 66.20 ft
1 OUTLET ELEVATION 669.22 ft
NUMBER OF BARRELS 1
SLOPE (V /H) 0.0076
1I CULVERT LENGTH ALONG SLOPE 66.20 ft
1
1
1
1
1
1�
1
DIS- HEAD- INLET OUTLET
CHARGE WATER CONTROL CONTROL FLOW NORMAL
FLOW ELEV. DEPTH DEPTH TYPE DEPTH
(cfs) (ft) (ft) (ft) <F4> (ft)
671.53
671.63
671.65
671.78
672.12
672.48
672.84
673.18
673.52
673.68
674.22
El. inlet face invert
El. inlet throat invert
CULVERT DATA SUMMARY
BARREL SHAPE
BARREL SPAN
BARREL RISE
BARREL MATERIAL
BARREL MANNING'S n
INLET TYPE
INLET EDGE AND WALL
INLET DEPRESSION
0.00 1.81 0 -NF 0.00
0.21 1.91 3 -Mlt 0.00
0.72 1.93 3 -Mlt 0.33
2.06 2.06 1 -S2n 0.95
2.40 2.40 1 -S2n 1.10
2.76 2.76 1 -S2n 1.26
3.12 3.12 1 -S2n 1.42
3.46 3.46 1 -S2n 1.58
3.80 3.80 1 -S2n 1.72
3.96 3.96 1 -S2n 1.79
4.50 4.50 5 -S2n 2.00
669.72 ft
0.00 ft
CRIT. CUTLET TW
DEPTH DEPTH DEPTH
(ft) (ft) (ft)
0.00
0.01
0.47
1.35
1.57
1.80
2.03
2.25
2.46
2.55
2.85
0.00
2.31
2.31
1.02
1.20
1.39
1.58
1.77
1.95
2.03
2.29
BOX
9.50 ft
4.00 ft
CONCRETE
0.012
CONVENTIONAL
SQUARE EDGE (30 -75 DEG. FLARE)
NONE
FILE DATE: 06 -24 -2008
FILE NAME: FTBOX
OUTLET TW
VEL. VEL.
(fps) (fps)
2.31 0.00
2.31 0.00
2.31 0.79
2.31 8.70
2.31 9.27
2.31 9.82
2.31 10.36
2.31 10.79
2.31 11.19
2.31 11.35
2.31 11.88
El. outlet invert 669.22 ft
El. inlet crest 0.00 ft
4
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
1
1 CURRENT DATE: 06 -24 -2008
CURRENT TIME: 14:57:08
I I' TAILWATER
CONSTANT WATER SURFACE ELEVATION
1 671.53
ROADWAY OVERTOPPING DATA
ROADWAY SURFACE PAVED
1 EMBANKMENT TOP WIDTH 36.00 ft
CREST LENGTH 50.00 ft
OVERTOPPING CREST ELEVATION 676.50 ft
1
1
1
1
1
1
1
1
1
1
1
1'
FILE DATE: 06 -24 -2008
FILE NAME: FTBOX
1�
1 1
1
1
1
1
1
1
1
1
1I
1
1�
1
1
11
1.
1
1
B. DRAINAGE AREA MAP
CALCULATIONS FOR STORM WATER
CONVEYANCE STRUCTURES
Brooke Road Phase 2
Frederick County, Virginia
January 17, 2008
Revised March 18, 2008
Revised August 16, 2008
Patton Harris Rust and Associates Project No. 15761 -1 -0
Prepared for:
Johnson Development Associates, Inc.
340 East Main St. Suite 500.
Spartanburg, SC 29304
Prepared by
Patton, Harris, Rust and Associates, PC
117 East Piccadilly Street
Winchester, VA 22601 -5002
(540) 667 -2139