HomeMy WebLinkAbout15-05 Impact AnalysisLargent Property Impact Analysis Statement September 2005
A. Location and Site Background
The following Impact Analysis Statement is provided in summary form for the proposed
development of the property referred to as the "Largent Property". The property is
located in the Shawnee Magisterial District. The property is situated along Airport Road
(VA Sec. Rt. 645), approximately 1.2 miles from the intersection of US Route 522 and
Airport Road. The property does not front Airport Road. The property is directly
southeast (behind) of the Winchester Regional Airport property that fronts Airport Road
(see Maps 1, 2 3). The parcel to be rezoned totals 30.01 acres. The parcel is
currently zoned Rural Areas (RA).
The requested rezoning is to change the current 30.01 acres from Rural Areas (RA) to
Light Industry (M -1).
There are no residential units proposed as part of this rezoning. A site development plan
for the proposed use will be prepared in accord with all local and state regulations.
The property proposed for rezoning is located within the Urban Development Area
(UDA) and inside the Sewer and Water Service Area (SWSA). Currently, the Frederick
County Sanitation Authority (FCSA) maintains a 12" water main and a 6" sewer force
main along Airport Road (VA Sec. Rt. 645) to serve this area.
Comprehensive Plan, Route 50 East Corridor Land Use Plan
The Land Use Plan for this area is contained within the Frederick County Comprehensive
Plan. This document is the most important tool that guides development in Frederick
County and specifically, in the area of this requested rezoning. The Comprehensive Plan
designates this area as a "Proposed Office /Industrial" area. The Comprehensive Plan
refers to this area's proximity to the Winchester Regional Airport as well as its easy
access to Interstate 81.
fblD
Triad Engineering, Inc.
Largent Property
B. Site Suitability
Impact Analysis Statement September 2005
The site is well suited for the intended development. It is estimated that 60% of the
property is suitable for actual construction and development due to steep slope areas.
These areas will be specifically addressed at the time of a site plan submission.
Access
On 22 March 2005 representatives from Triad Engineering, Inc. met with representatives
from VDOT and Frederick County Planning at the VDOT facility in Edinburg, VA. It
was agreed by all parties that a reconfiguration of the existing detention basin would be
required in order to provide an adequate area for the drive entrance in the Largent
property. In essence, the drive entrance will be created by an area swap that will be
addressed at the time of site plan submission.
100 Year Flood Plain
A portion of the parcel is within the designated areas of the 100 -year flood. This area is
located along Buffalo Lick Run. No structures are planned within the flood area. A
portion of the area contained within the floodplain will be put placed in a conservation
area/stream preservation corridor (see proffer statement and Map 8).
Wetlands
No wetlands have been identified on the site. The area contained of the property through
which Buffalo Lick Run flows will be preserved as a `Conservation Area' (see proffer
statement and Map 8). On the remaining portion of the property there is no evidence of
soils or plants in significant quantity to warrant delineation of wetlands.
Steep Slopes
The property generally slopes to the south and east. Steep slopes areas have been
identified on the site (see Map 6). These steep slope areas are generally the areas of
natural drainage into Buffalo Lick Run.
Mature Woodlands
The site contains no known mature woodlands.
Soils
There are no known critical soil areas on the site (see Map 7).
Comprehensive Planning
In the Frederick County Comprehensive Plan, the site is identified as part of a proposed
area of office and industrial growth.
TAAD
Triad Engineering, Inc.
Largent Property
C. Surrounding Properties
The site to be rezoned is bordered by Rural Areas (RA) zoning and Light Industrial (M -1)
Zoning. The adjoining properties to the west are all zoned Light industrial (M -1). The
property to the east is shown on the zoning map as being zoned Light Industrial (M -1),
however, the parcel information for this parcel (64- ((5)) -3) states that it is currently zoned
RA/M -1. The property to the south is zoned Rural Areas (RA) (see Maps 3 4).
The property to the northeast is owned by the Winchester Regional Airport and is the site
of the recent relocation of Airport Road (Rt. 645). This property now contains a
stormwater management basin (please see the Transportation section for more
information).
dlIAD
Triad Engineering, Inc.
Impact Analysis Statement September 2005
Largent Property
D. Transportation
Traffic
Impact Analysis Statement September 2005
A Summary of Trip Generation Rates was calculated using the ITE Trip
Generation Manual, 7ch Edition. The results show an average weekday 24 hour 2-
Way volume of approximately 1378 trips. The full summary of these rates is
shown in APPENDIX A. A summary of the average peak hour trips breaks down
as follows:
7 -9 AM Peak Hour Enter: 137.0
60 from US Route 522: 82.2
40% from US Route 50: 54.8
7 -9 AM Peak Hour Exit: 30.0
60% exit to US Route 522: 18.0
40% exit to US Route 50: 12.0
4 -6 PM Peak Hour Enter:
60% from US Route 522:
40% from US Route 50:
Entrance
Triad Engineering, Inc.
36.0
21.6
14.4
4 -6 PM Peak Hour Exit: 135.0
60% exit to US Route 522: 81.0
40% exit to US Route 50: 54.0
There are two main challenges to the planned construction of a commercial
entrance to the Largent property: 1) acquiring the necessary land to construct the
entrance on and 2) ensuring that the volume of the stormwater management pond
remains the same.
With the relocation of Airport Rd. (Rt. 645), the Winchester Regional Airport
Authority acquired a 5 acre parcel from the Largent property. The new section
of Airport Rd. and a stormwater management pond were created on this 5 acre
parcel. To provide access to the Largent property, VDOT constructed an
approximately 12 ft. wide gravel entrance across the Airport property. An
easement was not created. According to VDOT, it is the intention of the
Winchester Regional Airport Authority to deed to VDOT the surplus property on
the parcel adjacent to the Largent property. Once this is completed, VDOT will
be in a position to sell the property or a portion of the property for the
construction of a commercial entrance (see Map 9). As of 16 June 2005, VDOT's
rough estimate is that they will be in a position to sell within six months to a year.
Largent Property
Impact Analysis Statement September 2005
In order to construct a commercial entrance to this property, a larger allocation of
land will be needed. VDOT has stated that there are several options to explore in
order to provide enough land for a commercial entrance:
°R UD
Triad Engineering, Inc.
I) A permanent easement for the entrance
2) Partial sale of the entrance area
3) Sale of the entire parcel but preserving a VDOT maintenance easement
for the stormwater management pond
4) Other options
With regard to the stormwater management pond, VDOT has stated that it would
"...generally not have an objection to the applicant modifying the pond to install
the entrance, provided the stage /storage /discharge relationships are preserved
and road safety not affected"
It is the sincere intention of the property owner to work with VDOT to determine
the best course of action for both parties regarding the construction of a
commercial entrance and preserving the overall retention volumes of stormwater
from Airport Rd.
Largent Property
E. Sewage Treatment
There are no known limiting factors for the conveyance of sewage and sewage treatment
from this property. Capacity and daily usage will be addressed at the time of site plan
submission.
The site is located within the Sewer and Water Service Area (SWSA). A 6" sewer force
main exists along Airport Road and can service the site with an extension to the site of
approximately 350'.
Triad Engineering, Inc.
Impact Analysis Statement September 2005
Largent Property
F. Water Supply
There are no known limiting factors for supplying this site with water. Capacity and
daily usage will be addressed at the time of site plan submission.
The site is located within the Sewer and Water Service Area (SWSA). A 12" water main
exists along Airport Road and can service the site with an extension to the site of
approximately 300'.
Triad Engineering, Inc.
Impact Analysis Statement September 2005
Largent Property
G. Drainage
The site has no identified drainage problems. There are no streams or ponds located on
the site, except Buffalo Lick Run that briefly crosses the southern property line. Due to
the on -site slopes, drainage can be expected to flow south and east and enter into Buffalo
Lick Run.
An increase in storm water runoff can be expected with any development on the property.
Storm water management will be provided in accordance with the Frederick County
Code, Chapter 165. Further, the stormwater facility will be designed and engineered
using a Best Management Practice (BMP) approach so that the quality and quantity of
stormwater retained and discharged will meet all applicable environmental and
development standards.
CghlD
Triad Engineering, Inc.
Impact Analysis Statement September 2005
Largent Property
H. Solid Waste Disposal Facilities
No additional solid waste disposal facilities will be required for the proposed
development. Tipping fees are $38.00 per ton. A private solid waste hauler will handle
collection.
Z31AD
Triad Engineering, Inc.
Impact Analysis Statement September 2005
Largent Property Impact Analysis Statement September 2005
I. Historic Sites and Structures
The site contains no known historic sites or structures as listed on the National Register
or according to Frederick County GIS data.
TRIAD
Triad Engineering, Inc.
Largent Property
J. Community Facilities
Impact Analysis Statement September 2005
Education
A positive fiscal impact to education facilities is anticipated.
Emergency Services
The Frederick County Sheriff's Department provides police protection. The fire and
rescue facility designated to serve this site is the Millwood Fire and Rescue Company
located north of the site on Costello Drive. No additional fire and rescue facilities will be
required for the area proposed to be rezoned.
Parks and Recreation
A positive fiscal impact to parks and recreation facilities is anticipated.
Triad Engineering, Inc.
Airport Road (VA Sec. Rt. 645)
(this section now abandoned)
Approximate Location
New Airport Road
Completed OCT 2004
0 0.05 0.1
SCALES
0.2 0.3
0.4
0.5
Map 3
1:12,000
"Awned Location!1 Map
Largent Property
07 April 2005
1"= 1,000'
Miles
L(TJ P
N
Triad Engineering, Inc.
www.triad winc.com
Current Zoning The Largent Property
0 The Largent Property
Parcel lines
141 (Industrial, Light District)
rrn RA (Rural Areas District)
RP (Residential Performance District)
0 105210
a
1:4800
SCALES
420 630
07 April 2005
840
1" 400'
1,050
Feet
LE,
!f Triad Engineering, Inc.
www.triad- winc.com
Map4
Map 5
Floodplain The Largent Property
CP The Largent Property Streams
Parcel lines fJ Floodplain
Conservation Area 'T. 5' Contours
Please note that the Floodplain depicted on this
map is an approximation of the extents of the actual
Floodplain.
0 100200
1:4800
SCALES
400 600 800 1,000
Feet
1" 400'
°a�i[Ide�
07 April 2005
Triad Engineering, Inc.
www.triad- winc.com
The Largent Property
Slopes
0.00 5.00%
5.01 10.00%
10.01 15.00%
Slope Map The Largent Property
Parcel lines
15.01 20.00%
20.01 25.00%
25.01 90.00%
Contours
SCALES
0 105 210 420
1:3600
1" 300'
630
Feet
111LID
-/7
07 April 2005
Triad Engineering, Inc.
www.triad- winc.com map 6
u
0
L
O O
4 N 2
T T T
v
N Q co N
a zzz
0- b tn
r
V)riirN
O 0] V
U)rnrn
E
0
u
u
�o
0
0
0
0
N
0.