HomeMy WebLinkAbout19-12 Comments from other agenciesFREDEWK COUNTY SANITATION A *HORITY
SITE PLAN REVIEW COMMENTS ff
PO Box 1877, Winchester, VA 22604 -8377 540.868.1061 voice
315 Tasker *Road, Stephens City, VnA�22655 d ry 540.868.1429 fax
Project IV �� I ®�K`.. ��7i� �� UIitbj''
Applicant i� l`� W �y �N G�� gat M G
REVIEW STATUS
review number
correct & resubmit provHasno d
a ttention r—A)v D 7
number of items to be corrected
approved You may submit just cover sheet and the revised sheets.
DRAWINGS Q
send me by _5 12,77
1. print of sheets LL S Axer
2. two CDs: each disc shall contain the following plan sheets
a) One CD (containing all of the above noted sheets) shall be in PDF format. Each sheet shall
be in its own file and be in landscape orientation. Each file shall be titled with the project
name and appropriate sheet number.
b) One CD (containing all of the above noted sheets) shall be in DWG format. Each sheet shall
be in its own file and each sheet shall be titled with the project name and with the
appropriate sheet number. Each sheet shall (1) be in landscape orientation, (2) be without
border, (3) be in state plane coordinate system NAD 83, and (4) be compatible with
AutoCAD 2006.
c) Each of the two CDs shall be labeled with its format and project name, and placed in its own
paper CD envelope.
EASEMENTS
®/ N A copy of the recorded onsite wat and/or easement(s) is /are required.
Y / A copy of the recorded offsite water and/or sewer easement(s) is /are re ' d
The easement document shall contain a plat and both shall be signed by the Authority.
The Authority requires specific language in its deed of easement. Contact this office to i a copy �r
of the form. >-
A copy of the recorded deed(s) of easement shall be received before service will be aut o
OTHER Z W
Y 0 This project also requires DEQ - Valley Region Office approval. � � �
Y /® This project also requires VDH — Lexington Field Office approval.
Y ® This project has a sewer pump station that FCSA will own. Title to the pus tion site
shall be granted to the Authority in fee simple absolute. Also, (1) a co f�?EQss•
Certificate to Construct, (2) a copy of DEQ's Certificate to Operate, and (3) two copies of
the FCSA approved O & M manual are required. These documents must be received before
service will be authorized. /
qq W
Date: V 113111
Earl W. Wiley —Engineering Assistant MAR 2012
August 13, 2012
•
•
WINCHESTER REGIONAL AIRPORT
491 AIRPORT ROAD
WINCHESTER, VIRGINIA 22602
(540) 662 -5786
Donna Meliso, Administrative Coordinator
Greenway Engineering
151 Windy Hill Lane
Winchester, Virginia 22602
Re: Site Plan Revision Comment
Navy Federal Credit Union
141 Independence Drive —Winchester, VA
Shawnee Magisterial District
Dear Ms. Meliso:
I have reviewed the FAA's determination regarding the proposed building for the Navy Federal Credit
Union Building Expansion. According to the FAA, the proposed building at a maximum height of fourty-
four (44) feet will not be a hazard to air navigation therefore it is not a requirement to light the proposed
structure with obstruction lights.
Please note that any changes in the maximum height and/or elevations as submitted to the FAA, would
require a separate review by this office and the FAA. This would include any /all appurtenances (i.e.
HVAC systems, antennas, vent stacks, etc) that would exceed the height previously listed.
In addition, the determination study does not include any temporary construction equipment such as
cranes, derricks, etc. that exceed the submitted height. The use of equipment during construction
requires a separate 7460 -1 to be filed with the FAA with a copy forwarded to this office for record.
All comments in my review letter of May 24, 2012 have been incorporated into the notes section as
requested.
This completes our review. Thank you for your continued cooperation and support during this process.
If you have any questions or need additional information, please do not hesitate contacting my office.
Sincerely,
QL
Serena R. Manuel
Executive Director
Mail Processing Cen* • Aeronautical Study No.
Federal Aviation Administration 2012- AEA - 3440 -OE
Southwest Regional Office
Obstruction Evaluation Group
2601 Meacham Boulevard
Fort Worth, TX 76137
Issued Date: 08/13/2012
Stacey Purinton
Navy Federal Credit Union
820 Follin Lane
Vienna, VA 22180
** DETERMINATION OF NO HAZARD TO AIR NAVIGATION **
The Federal Aviation Administration has conducted an aeronautical study under the provisions of 49 U.S.C.,
Section 44718 and if applicable Title 14 of the Code of Federal Regulations, part 77, concerning:
Structure: Building Navy Federal Credit Union
Location: Winchester, VA
Latitude: 39- 08- 14.52N NAD 83
Longitude: 78- 07- 44.46W
Heights: 683 feet site elevation (SE)
44 feet above ground level (AGL)
727 feet above mean sea level (AMSL)
This aeronautical study revealed that the structure does not exceed obstruction standards and would not be a
hazard to air navigation provided the following condition(s), if any, is(are) met:
It is required that FAA Form 7460 -2, Notice of Actual Construction or Alteration, be completed and returned to
this office any time the project is abandoned or:
At least 10 days prior to start of construction (7460 -2, Part I)
_X_ Within 5 days after the construction reaches its greatest height (7460 -2, Part II)
Based on this evaluation, marking and lighting are not necessary for aviation safety. However, if marking/
lighting are accomplished on a voluntary basis, we recommend it be installed and maintained in accordance
with FAA Advisory circular 70/7460 -1 K Change 2.
This determination expires on 02/13/2014 unless:
(a) the construction is started (not necessarily completed) and FAA Form 7460 -2, Notice of Actual
Construction or Alteration, is received by this office.
(b) extended, revised, or terminated by the issuing office.
(c) the construction is subject to the licensing authority of the Federal Communications Commission
(FCC) and an application for a construction permit has been filed, as required by the FCC, within
6 months of the date of this determination. In such case, the determination expires on the date
prescribed by the FCC for completion of construction, or the date the FCC denies the application.
Page 1 of 2
NOTE: REQUEST FOR EXTERN OF THE EFFECTIVE PERIOD OARS DETERMINATION MUST
BE E -FILED AT LEAST 15 DAYS PRIOR TO THE EXPIRATION DATE. AFTER RE- EVALUATION
OF CURRENT OPERATIONS IN THE AREA OF THE STRUCTURE TO DETERMINE THAT NO
SIGNIFICANT AERONAUTICAL CHANGES HAVE OCCURRED, YOUR DETERMINATION MAY BE
ELIGIBLE FOR ONE EXTENSION OF THE EFFECTIVE PERIOD.
This determination is based, in part, on the foregoing description which includes specific coordinates , heights,
frequency(ies) and power. Any changes in coordinates , heights, and frequencies or use of greater power will
void this determination. Any future construction or alteration , including increase to heights, power, or the
addition of other transmitters, requires separate notice to the FAA.
This determination does include temporary construction equipment such as cranes, derricks, etc., which may be
used during actual construction of the structure. However, this equipment shall not exceed the overall heights as
indicated above. Equipment which has a height greater than the studied structure requires separate notice to the
FAA.
This determination concerns the effect of this structure on the safe and efficient use of navigable airspace
by aircraft and does not relieve the sponsor of compliance responsibilities relating to any law, ordinance, or
regulation of any Federal, State, or local government body.
Any failure or malfunction that lasts more than thirty (30) minutes and affects a top light or flashing obstruction
light, regardless of its position, should be reported immediately to (877) 487 -6867 so a Notice to Airmen
(NOTAM) can be issued. As soon as the normal operation is restored, notify the same number.
If we can be of further assistance, please contact our office at (817) 321-7755. On any future correspondence
concerning this matter, please refer to Aeronautical Study Number 2012- AEA - 3440 -OE.
Signature Control No: 168711141 - 170959631
Debbie Cardenas
Technician
Page 2 of 2
(DNE)
• •
REQUEST FOR SITE PLAN COMMENTS
Virginia Department of Transportation
Mail to:
Virginia Department of Transportation
Attn: Resident Engineer
14031 Old Valley Pike
Edinburg, Virginia 22824
Phone: (540) 984 -5600
Hand deliver to:
Virginia Department of Transportation
Attn: Resident Engineer
2275 Northwestern Pike
Winchester, Virginia 22603
Applicant: Please fill out the information as accurately as possible in order to assist the Virginia Department of
Transportation with their review. Please attach fflyg (S) copies of the site plan with traffic generation data and drainage
calculations with this sheet.
Applicant's Name: Greenway Engineering, Inc Telephone: 540 - 662 -4185
Mailing Address: 151 Windy Hill Lane
Winchester, VA 22602
Name of development and/or description of the request:
Navy Federal Credit Union -Site Plan Revision
Location of Property:
Westview Business Center, 141 Independence Drive, Winchester, Frederick County
Virginia Department of Transportation Comments:
See attadW Ei1HLl dated ft 30- 2012 firrm Tknnd Anml- ZM to R z X=Jer wth
GreaW HV�r�
- - - - -- - -- -VDOT USE ONLY-
Date Received Review Number 1 2 3 4 5 (circle one)
Date Reviewed
I Revision Required Date Approved
VDOT Signature & Date: ° 05/30/2M
** Please Return Form to Applicant **
15
Donna Meliso
Subject: FW: Navy Federal Credit Union - Westview Business Centre Lot 12
Attachments: FredCo VDOT Comments_NFCU.pdf
From: Atwood, David (VDOT) [mailto: David .At:wood(&vdot.virginia.govl
Sent: Wednesday, May 30, 2012 9:04 AM
To: Randy Kepler; Donna Meliso
Cc: rsargent@co.frederick.va.us; ineaWbco.frederick.va.us; Funkhouser, Rhonda (VDOT)
Subject: Navy Federal Credit Union - Westview Business Centre Lot 12
It
CUM
DEPARTMENT OF TRANSPORTATION
Staunton /Edinburg Land Development
14031 Old Valley Pike
Edinburg, VA 22824
VDOT has reviewed the Site Plan dated April 30, 2012 by Greenway Engineering, Inc. for the Navy Federal Credit Union
(Westview Business Centre Lot 12) Project. Based on the review, VDOT has no comments regarding the Site Plan. It is
understood that no construction is proposed within VDOT Right -of -Way. If any questions or concerns should arise
concerning impacts to the State roadway system, please do not hesitate to contact me.
Sincerely,
David B. Atwood, P.E.
Land Development Engineer
VDOT I Land Development
Clarke, Frederick, Shenandoah, & Warren Counties
14031 Old Valley Pike
Edinburg, VA 22824
Phone # (540) 984 -5630
Fax # (540) 984 -5607
Fax from : 5486784739 •
• 87 -31 -12 89:16 Pg: 1
_ - recieric#� "fount Fi g i �cl.A6tcue
-
4
C1fice ®f_Ee ='Fire airs
hal _
_ _- =
. _ RleIIiLLF2e ie _a`Irild Commen S"",
Control number Date received Date reviewed Date Revised
SP 12 - 0008 R 5!7/2012 5/31/2012 6/15/2012
Project Name Applicant
Navy Fed. 141 Independence Dr. Greenway Engineering Inc.
Address City State Zip Applicant Phone
151 Windy Hill Lane Winchester VA 22602 54t- 662 -4185
Type Application Tax ID Number Fire District Rescue District
Site plan 21 21
Election District
Shawnee
Residential Sprinkler System
No
Fire Lane Required
Yes
Special Hazards
No
Current Zoning
Automatic Sprinkler System
Yes
Other recommendation
Emergency Vehicle Access
Adequate
Siamese Location
Adequate
Emergency Vehicle Access Comments
Access Comments
Additional Comments
Plan Approval Recommended
Yes
Recommendations
Automatic Fire Alarm System
Yes
equirements
Hydrant Location
Adequate
Roadway /Aisleway Width
Adequate
Reviewed By Signature
S. Mark Showers Title
Jul. 3 1 2012
G , EENWAY
.IIGINEERING
COUNTY of FREDERICK
Department of Public Works
540/665 -5643
FAX: 540/678 -0682
June 25, 2012
Mr. Randy Kepler
Greenway Engineering
151 Windy Hill Lane
Winchester, Virginia 22602
RE: Site Plan Comments — Navy Federal Credit Union
Lot 12 Westview Business Center
Frederick County, Virginia
Dear Randy:
Upon review of the revised site plan dated May 31, 2012, all of our previous comments
have been addressed. Therefore, we recommend approval of the subject plan.
Sincerely,
Joe C. Wilder
Deputy Director of Public Works
JCW /rls
cc: Planning and Development
file
T:\ Rhonda\ TEMPCOMMENTS \NAVYFEDERALCREDUNION - LOT 12 REVSPCOM.doc
REQUEST FOR SITE PLAN COMMENTS
Frederick County Inspections
Department Comment
Mail to:
Frederick County Inspections Department
Attn: Building Official
107 North Kent Street,
Winchester, Virginia 22601
Hand deliver to:
Frederick County Inspections Dept.
107 North Kent Street, 2nd Floor
Winchester, Virginia 22601
Phone: (540) 665 -5650
Applicant: It is your responsibility to complete this form as accurately as possible in order to assist the agency with their
review. Please attach two (2) cog_ies of the Site Plan with this sheet
Applicant's Name: Greenway Engineering, Inc
Mailing Address:
151 Windy Hill Lane
Winchester, VA 22602
Name of development and/or description of the request:
Navy Federal Credit Union -Site Plan Revision
Telephone: 540 -662 -4185
t- 39913
Location of Property:
Westview Business Center, 141 Independence Drive, Winchester, Frederick County
Inspections Department Comments: -`
l iL
- FREDERICK COUNTY INSPECTIONS DEPARTMENT USE ONLY-
Date Received Review Number 1 2 3 4 5 (circle one)
Date Reviewed -
Revision Required Date Approv a
Signature & Date: ?i' 1-7i t,-
n *: PleW Return Form to Applicant"
Office building shall comply with The Virginia Uniform Statewide Building Code section 304,
use group B (Business), of the International Building Code/2009.Other Code that applies is
IBC /ANSI Al 17.1 -03 Accessible and Usable Buildings and Facilities.
Proposed new 54048 sq ft, two story, office building shall comply with Section 507 for unlimited
area buildings. Building is fully sprinkled. All required egress shall meet ANSI Handicap.
Exits indicated on plans and entrances appear to meet ANSI. Question on accessible route and
accessible entrance at Canopy side. Please provide elevation marks to verify max 2% cross slope
and accessible route from parking area to accessible entrance. Currently cross slope appears to
be 11 ".
T1106.1 IBC requires 7 accessible parking spaces and 9 have been provided. Verify van
accessible parking and signage. Question on unloading area not provided on west side of
building.
The building will require an accessible route to the second floor (ie elevator)
Retaining walls require a building permit and plans shall be detailed by a registered design
professional licensed in the State of Virginia
This type structures shall be subject to special inspections according to chapter 17 of the IBC.,
(soils, concrete, etc.).
Generator and storm water reclamation tank require building permits and shall comply with The
Virginia Uniform Statewide Building Code and Section 312, use group U (Utility and
Miscellaneous) of The International Building Code 2009.
7 -23 -12 Canopy entrance route appears to be located on an accessible route. Van accessible
parking now has unloading as required per 1106 IBC. 60% of all entrances shall be located on an
accessible route.
Note: Unlimited area per Section 507 is optional. Height and area shall comply with T503 IBC.