Loading...
HomeMy WebLinkAbout17-12 Comments and correspondencei November 19, 2012 Mr. Todd Heck Bowman Consulting Group 101 South Street SE Leesburg, Virginia 20175 RE: Approval of Site Plan #17 -12; 7- Eleven Property Identification Number (PIN): 64 -A -103 Dear Mr. Heck: Department of Planning and Development 540/665 -5651 The above - referenced site plan was approved on November 19, 2012. This site plan is approved for the construction of a 7 -11 Convenience and Gas Station (demolition and rebuild) at 1026 Millwood Pike (Route 50E) in the Shawnee Magisterial District. Required site improvements include the following: • Construction of a 3,700 square foot convenience store, ten gasoline pumps under one canopy. C Construction of a parking lot with 15 spaces (including one handicap accessible), including curb and gutter, striping and handicap access. • One loading space and one screened dumpster area. • Construction of a sidewalk along Route 50. C Landscaping and lighting as shown on the site plan. All requirements of the Frederick County Zoning Ordinance have been met in the approved site plan, including review agency comments from all relevant review agencies. I am providing you with three (3) copies of the approved site plan. Please forward these copies to the appropriate representative(s). Furthermore, advise the owner(s) that a copy should be kept for future reference, and an approved copy must be kept on the construction site throughout the development process. Once site development is complete, the owner(s) should contact this office to schedule an on -site inspection. Do not hesitate to contact me if you have any questions or concerns. Sincerely, Candice E. Perkins, AICP, Senior Planner Attachments CEP /bad cc: Jane Anderson, Real Estate Gene Fisher, Shawnee District Supervisor Lawrence Ambrogi and H. Paige Manuel, Shawnee Planning Commissioners Commissioner of Revenue Winchester Millwood Avenue LLC, PO Box 8, Mount Jackson, VA 22842 107 North Dent Street, Suite 202 o Winchester, Virginia 22601 -5000 _ ao O M D D rr J C rr D 1 7- Eleven Frederick County, VA AX "A C 1 .4 n • U . �o -o - ,m O ZNiz C-4 o� cN o)>� y rn o o •w - moCD= r O -4 m m m N m D � oC') y n m� m M m U) D � z C m COUNTY of FREDERICK Department of Planning and Development 540/665 -5651 FAX: 540/665-6395 October 26, 2012 Mr. Christopher Mohn Bowman Consulting Group 101 South Street SE Leesburg, Virginia 20175 Re: Second Review Comments for Site Plan #17 -12; 7- Eleven Property Identification Number (PIN): 64 -A -103 Dear Chris: Planning Staff has reviewed the above - referenced site plan to determine if administrative approval can be granted. At this time, administrative approval cannot be granted because it has not addressed previous staff comments and the plan does not conform to the requirements of the Frederick County Zoning Ordinance. This site plan is denied until the issues in this letter, as well as all issues of the other review agencies, have been adequately addressed. Please review Staff's comments listed below and prepare a revised site plan which adequately addresses each concern. Review Comments: 1) General Notes. On the coversheet, provide a note stating that all utilities must be underground. 2) Si na e. On sheet 2A, for the sign detail, the area between the top sign panel and the LED signs needs to have a blank panel inserted. 3) Landscaped Islands. A landscaped island is required at both ends of the parking bay at the front of the convenience store as well as the parking spaces at the western property line. 4) CG -6 Requirement. The use of wheelstops and CG -2 is only permitted when LID techniques are utilized. It does not appear that this site is utilizing any LID techniques and, therefore, CG -6 is required as indicated on sheet 5. 5) Route 50 Sidewalk. The sidewalk along Route 50 needs to be continued as indicated along the entire site frontage; crosswalks need to be provided as well. 6) Site Lighting. The following needs to be addressed on the photometric plan: o The canopy lighting does not appear to meet the outdoor lighting standards. Light fixtures under fuel station canopies or any other canopy shall consist of full cut -off lighting fixtures where the light source is either completely flush or recessed within the underside of the canopy. The portions of the canopy not included in the sign area shall not be illuminated. All canopy lighting shall be recessed sufficiently so as 107 North Kent Street, Suite 202 o Winchester, Virginia 22601 -5000 Mr. Christopher Mohn 0 Re: 7- Eleven Site Plan #17 -12 October 26, 2012 Page 2 to ensure that no light source is visible from or causes glare on adjacent properties or road right -of -warms. • The lighting levels indicated for this site exceed the maximum permitted. The average maintained lighting levels for nonresidential uses shall not exceed the following standards: a) Five (5) foot - candles for parking lots and loading areas. b) Ten (10) foot - candles along fronts of buildings and along main drive aisles. c) Twenty (20) foot - candles for vehicle fuel station canopies, but not including parking lots. • Lighting levels shall not exceed 5.0 foot - candles at any common property line with property zoned or used for commercial or industrial uses, and at any edge of a property line adjacent to a road right -of -way. • Description of all lighting fixtures needs to be provided on the photometric plan. This needs to consist of catalog cuts and illustrations by manufacturers that describe the equipment, including lamp types, wattage and initial lumen outputs, glare control devices, lamps, proposed placement of all fixtures, including engineering detail of fixtures, manufacturer, model and installation of same. After you have revised the site plan, please resubmit one copy so that I may verify the information contained on the plan. I will need all approved review agency comment sheets and at least five copies of the final plan for approval. Comment sheets are required from the following agencies: the Frederick County Sanitation Authority (approved as noted are not acceptable) and the Virginia Department of Transportation. Sincerely, .rte/ Candice E. Perkins, AICP Senior Planner cc: Winchester Millwood Avenue LLC, PO Box 8, Mount Jackson, VA 22842 Attachment CEP/bad 9 0 Bow,mvan 0 October 23, 2012 Mr. David B. Atwood, P.E. VDOT 14031 Old Valley Pike Edinburg, VA 22824 RE: Route 50 7- Eleven (Millwood Pike) BCG Project #5395 -01 -001 Dear Mr. Atwood: We have received your comments dated October 12, 2012 and offer the following in response. "General: The previously submitted design waiver for entrance spacing has been approved by VDOT. " Response: Acknowledged. 2. "General: Revise the VDOT General Notes to match those attached to this email. " Response: The VDOT General Notes found on Sheet 1 have been revised as suggested. 3. "General: Provide a Transportation Management Plan including 2011 Virginia Work Area Protection Manual Standard Details (VWAPM), Traffic Control Plan and Narrative, and Public Communications Plan for a Type "A " Project. A guide sample has been attached for your use in creating the TMP. According to the discussions during the Otiimer /Contractor Meeting, the work within VDOT Right -of -Way should be able to be completed in one to two days, which would require a shoulder closure in accordance with VWAPMFigure- TTC-4. 0 and /or 7-TC -5.0. Insert the TTC details and Traffic Control Narrative on the Plans. At most, a minor encroachment into the roadway may be required to tie in the existing roadway asphalt. " Response: A Transportation Management Plan has been added on Sheet 9. 4. "General: According to discussions with the Owner, the existing paved entrances will be removed and replace with concrete entrance treatments. Please show these improvements on the plan and include a detail of the proposed entrance(s) with a profile (for drainage) and direction for how to tie the concrete apron to the existing Pavement of the adjacent travel lane. " Response: The Grading Plan has been revised to include the concrete entrance treatments. Entrance profiles have been provided on Sheet 5, with direction for the construction of the proposed entrance improvements. As indicated on the plans, the existing curb and drainage patterns will remain as they exist today. Only the asphalt pavement will be replaced. Bowman Consulting Group, Ltd. 101 South Street, SE • Leesburg, Virginia 20175 Phone: 703.443.2400 • Fax: 703.443.2425 • bowmanconsulting.com Mr. David B. Atwood, P.0 19 October 23, 2012 Page 2 of 2 Should you have any further questions please feel free to contact me at the office. Sincerely, BOWMAN CONSULTING GROUP, LTD. Todd Heck Project Manager cc: Dexter Mumaw • 0 Bowman C O N S U L T I N G September 11, 2012 Mr. Dana M. Johnston, CZO- —7 Zoning Inspector Frederick County J L S E P 1 2 2012 107 N. Kent Street L Winchester, VA 22602 F H'6)'E' R -I CK COUNTY 0, Vr LOPIAIENT RE: Route 50 7- Eleven - PIN: 64 -A -103 BCG Project #5395 -01 -001 Dear Mr. Johnston: We have received your comments dated August 1, 2012 and offer the following in response. Sheet 2 1. "Zoning Data. Change front yard setback from 35 feet to 50 feet. " Response: The front yard setback has been revised to 50'. Please see Sheet 2. 2. - -,Details. Provide details for signs. " Response: A detail showing the conversion of the existing sign to the required monument style has been provided on Sheet 2A. Sheet 3 & 4 3. "General Annotations. Annotate name of R O. W (See mark up) " Response: The name of the existing right -of -way Delco Plaza has been provided on Sheets 3 and 4, per the provided mark -up. Sheet 5 4. "Signs. Note that the existing Interstate Overlay Sign is to remain. The sign on the north part of the property would have to be brought to today's Zoning Ordinance standards. " Response: The existing Interstate Overlay Sign has been noted to remain on Sheet 4. A detail showing the conversion of the existing sign to the required monument style has been provided on Sheet 2A. - 5. "Setback. The front setback is annotated at 35 feet; it should be 50 feet. " Response: The front yard setback line has been revised to 50' from the property line. Please see Sheet 3. Bowman Consulting Group, Ltd. 101 South Street, SE • Leesburg, Virginia 20175 Phone: 703.443.2400 • Fax: 703.443.2425 - bowmanconsulting.com Mr. Dana M. Johnston, CZO0 September 11, 2012 Page 2 of 2 6 "Entrance. One of the two entrances needs to be vacated. What is the VDOT comment? " Response: To provide needed vehicle circulation for fueling operations, the entrances being utilized by this site are existing entrances which are not being altered. The entrance spacing requirements provided in Section 165- 202.03 are specifically for new entrances. VDOT suggests that a request for an exception to the spacing standard be submitted. The appropriate form will cite the parcel's location on an older, established business section of a highway corridor where existing spacing did not meet the spacing standards prior to July 1, 2008 as justification for the exception, per VDOT comments. "Curb and Gutter. Curb type is noted as a CG -2; this should be CG -6 Also, with a CG -6 curb, are wheel stops necessary? " Response: As per your discussion with Nathan Bales on September 7, 2012, 6" curb will be provided through the use of CG -2. The standard VDOT CG -2 detail appears on Sheet 2. Wheel stops are provided in front of the building where flush curb is used to allow ADA access, and in the northeast corner of the site where there is no curb to promote drainage to the nearby concrete channel. 8. "Lab elin . See sheet for additional comments. " Response: All suggested labels have been provided per the attached markup. "Sidewalk. Five foot side is required per Ordinance along Millwood Pike. " Response: Due to the location of the site between two properties without sidewalk along the frontage, one of which received Site Plan approval for a similar use within the past two years, a five foot sidewalk along Millwood Pike is not provided. Moreover, it is unclear which zoning ordinance section specifies that provision of a 5' sidewalk along the road right -of -way is required. 10. "Landscaping. As part of the plant schedule, please annotate height at planting." Response: The plant schedules on Sheet 7 have been revised to include height at planting. 11. "Wall mounted lights. Provide a note that all wall fixture lights shall be shielded. " Response: A note has been added on Sheet 8 stating that all wall fixture lights will be shielded. Should you have any further questions please feel free to contact me at the office. Sincerely, BOWMAN CONSULTING GROUP, LTD. U �( Cody Fr is, P.E. Director of Engineering 0 0 Bowman C O N S U L T 1 N G October 24, 2012 Mr. Dana Johnston Department of Planning & Development Frederick County 107 North Kent Street Winchester, VA 22601 RE: Route 50 7- Eleven Plan Number 17 -12 BCG Project #5395 -01 -001 Dear Mr. Johnston: Please find attached a revised Rte. 50 7- Eleven Site Plan. The revisions include those made to address VDOT comments, the location of existing underground fuel storage tanks as requested by the Dept. of Public Works for conditional approval, the items requested by FCSA for conditional approval, and the inclusion of the 5' sidewalk along Millwood Pike. Also, approval letters from all of the Frederick County Departments are attached in preparation for final Site Plan approval. Please contact me at the office if you have any further questions. Sincerely, BOWMAN CONSULTING GROUP, LTD. Todd Heck Project Manager cc: Harvey Strawsnyder (Department of Public Works) Earl Wiley (Frederick County Sanitation Authority) Bowman Consulting Group, Ltd. 101 South Street, SE - Leesburg, Virginia 20175 Phone: 703.443.2400 - Fax: 703.443.2425 - bowmanconsulting.com September 19, 2012 Mr. J. W. Cody Francis, P.E. Bowman Consulting Group, LTD 101 South Street, SE Leesburg, Virginia 20175 RE: Site Plan Review for Route 50, 7- Eleven Frederick County, Virginia Dear Mr. Francis: COUNTY of FREDERICK Department of Public Works 540/665-5643 FAX: 540/678 -0682 Your response letter dated September 11, 2012 has adequately addressed a majority of our comments dated August 1, 2012. The only exception is your response to our previous comment 42. We would appreciate a plan showing the exact number and location of each underground fuel tank. The revised site plan documents dated September 10, 2012 are approved by the public works department pending receipt of the above referenced plan. Sincerely, Harvey. Strawsnyder, Jr., P.E. Director of Public Works HES /rls cc: Planning and Development file tARhonda \TEMPCOMMENTS\RT 50 7 -11 REV SP COM.doc 1� o� Coy COUNTY of FREDERICK w Department of Planning and Development 540/665 -5651 FAX: 540/665-6395 August 1, 2012 Mr. Christopher Mohn Bowman Consulting Group 101 South Street SE Leesburg, Virginia 20175 Re: Review Comments for Site Plan #17 -12; 7- Eleven Property Identification Number (PIN): 64 -A -103 Dear Chris: Planning Staff has reviewed the above - referenced site plan to determine if administrative approval can be granted. At this time, administrative approval cannot be granted. This site plan is denied until the issues in this letter, as well as all issues of the other review agencies, have been adequately addressed. Please review Staff's comments listed below and then prepare a revised site plan which adequately addresses each concern. I have attached a marked copy of the plans to assist with the revisions. Review Comments Sheet 2 1. Zoning Data. Change front yard setback from 35 feet to 50 feet. 2. Details. Provide details for signs. Sheet 3 & 4 3. General Annotations. Annotate name of R.O.W. (See mark up.) Sheet 5 4. Sims. Note that the existing Interstate Overlay Sign is to remain. The sign on the north part of the property would have to be brought to today's Zoning Ordinance standards. 5. Setback. The front setback is annotated at 35 feet; it should be 50 feet. 6. Entrance. One of the two entrances needs to be vacated. What is the VDOT comment? 7. Curb and Gutter. Curb type is noted as a CG -2; this should be CG -6. Also, with a CG- 6 curb, are wheel stops necessary? 8. Labeling. See sheet for additional comments. 9. Sidewalk. Five foot side is required per Ordinance along Millwood Pike. 107 North Kent Street, Suite 202 o Winchester, Virginia 22601 -5000 • Mr. Christopher Mohn Re: 7- Eleven Site Plan #17 -12 August 1, 2012 Page 2 Sheet 7 10. Landscaping. As part of the plant schedule, please annotate height at planting. Sheet 8 11. Wall mounted lights. Provide a note that all wall fixture lights shall be shielded. After you have revised the site plan, please resubmit two copies, plus the marked copy that was provided for you, so that I may verify the information contained on the plan. I will need all approved review agency comment sheets and at least five copies of the final plan for approval. Do not hesitate to contact me if you have any questions or concerns regarding this letter. Ijana M. Johnston, Zoning Inspector DMJ/bad cc: Winchester Millwood Avenue LLC, PO Box 8, Mount Jackson, VA 22842 Attachment