HomeMy WebLinkAbout01-05 Impact AnalysisFile #3701/EAW /aje
IMPACT STATEMENT
RUSSELL 150
REZONING
Shawnee Magisterial District
Frederick County, Virginia
TM 64- ((A)) -10 64- ((A)) -12
150.28 -Acres
November 3, 2004
revised January 24, 2005
Current Owners: Russell 150, LC
Applicant: Russell 150, LC
Contact Person: Mark Smith, PE LS
Greenway Engineering
151 Windy Hill Lane
Winchester, VA 22602
540 662 -4185
Greenway Engineering November 3, 2004 Russell 150 Rezoning
Revised January 24, 2005
INTRODUCTION
RUSSELL 150 REZONING
This report has been prepared for the purpose of assessing the impact on Fredrick County by
the proffered rezoning of a 150.28 -acre subject property identified as Russell 150 and owned
by Russell 150, LC. The subject property consists of two parcels, those being: TM 64- ((A))-
10; 29.97 acres, and 64- ((A)) -12; 120.31 acre. The subject site is located on the west side of
Front Royal Pike (Route 522), opposite Airport Road (Route 645). The property is traversed
by the future alignments and intersections of three major thoroughfares. The current zoning
is Rural Areas (RA) District. The applicant, Russell 150, LC proposes to rezone the parcel
from Rural Areas (RA) to Business General (B2) District and Residential Performance (RP)
District. (Reference Attachment 1. Location and Existing Zoning Exhibit for Russell 150)
Basic information
Location:
Magisterial District:
Property ID Numbers:
Current Zoning:
Current Use:
Proposed Use:
Proposed Zoning:
Total rezoning area:
Proposed build -out
Fronting on the west side of Front Royal Pike (Route
522), opposite Airport Road (Route 645)
Shawnee
64- ((A)) -10 and 64- ((A)) -12
Rural Areas (RA) District
Agricultural, Unimproved
Commercial, Office and Retail
Residential, Attached single family
Business General (B2) District and
Residential Performance (RP) District
150.28 acres
440,450 square feet commercial retail
264,000 square feet office
294 residential attached single family units
File #370I/EA W /aic 2
Greenway Engineering November 3, 2004 Russell 150 Rezoning
Revised January 24, 2005
COMPREHENSIVE PLAN
The subject property is located wholly within the Sewer and Water Service Area (SWSA)
and Urban Development Area (UDA). No expansion of the SWSA or UDA is required for
development of the subject property.
The property is also included in the study area boundary of the Route 50 East Corridor Land
Use Plan. The Comprehensive Policy Plan 1999, Route 50 East Corridor Land Use Plan
states on page 6 -19:
An area of business /office use is also shown west of the intersection of Airport Road
and Route 522. This area would be expected to accommodate a future road
connection resulting from the extended of Airport Road, west into the City. Plans at
this time would be to connect with road segments which are, at this time, partially in
place south of Lowes, extending east from Pleasant Valley Road. This connection is
seen as an important link in the overall Winchester Area Transportation Plan.
The Comprehensive Policy Plan, Eastern Road Plan, page 7 -15 and the Winchester Area
Transportation Study (WATS) depict "new major collectors" of Warrior Drive and Airport
Road extended crossing and intersecting on the subject property. In further refinements of
these plans, VDOT has stated a desire for East Tevis Street to be the through movement in
the Warrior Drive intersection, and Airport Road to connect Warrior Drive with a roundabout
intersection. The roadways proffered through the generalized development plan are in
conformance with these comprehensive planning documents.
The Frederick County Bicycle Plan is depicted on page 7 -17 of the Comprehensive Policy
Plan. The bikeways, discussed further in the Transportation section of this report, and
proffered through the generalized development plan, is in substantial conformance with the
Comprehensive Policy Plan.
The subject property north of Buffalo Lick Run and west of Warrior Drive is to be developed
in business /office uses, in complete conformity with the Comprehensive Policy Plan, Route
50 East Corridor Land Use Plan. The Buffalo Lick Run stream valley forms a natural buffer
and dividing line between these business /office uses and residential uses to the south. The
Comprehensive Policy Plan 1999, Route 50 East Corridor Land Use Plan graphic on page 6-
21 shows exactly that, with a bubble labeled "proposed business /office" above a line
identified as "urban development area" and "corridor boundary corresponding to that
labeled Buffalo Lick Run. The single land bay situated south of the Buffalo Lick Run stream
valley, between Front Royal Pike (Route 522) to the east and Warrior Drive to the west, is to
be developed in a residential use. This residential land bay comprises approximately twenty
five percent of the total project area. The proposed residential use of this land bay is in
substantial conformance with the Comprehensive Policy Plan, and is in keeping with
principles of good planning.
File #3701/EAW /ajc 3
Greenway Engineering November 3, 2004
Revised January 24, 2005
I. Urban Development Area
Russell 150 Rezoning
Expansion of the Urban Development Area (UDA) beyond its existing boundary is not
required by this application.
2. Sewer and Water Service Area
Expansion of the Sewer and Water Service Area (SWSA) beyond its existing boundary is not
required by this application.
A. SUITABILITY OF THE SITE
Access
The subject site, consisting of tax parcels 64- ((A)) -10 and 64- ((A)) -12, is located within a
manmade boundary created by Front Royal Pike (Route 522) on the eastern frontage of the
property and 1 -81 along the western side.
Access to the various land bays within the subject site will generally be from the planned
major thoroughfares of Warrior Drive, Airport Road extended, and East Tevis Street. The
subject property has approximately 220 feet of frontage on Front Royal Pike (Route 522).
Airport Road extended will create a four -way intersection with Front Royal Pike. The
residential land bay will have a single connection to Front Royal Pike, and a single entrance
on Warrior Drive. It is noted that no individual commercial lot access is proposed from
Front Royal Pike. Safe entrance separation distances from the roundabout and other major
thoroughfare intersections will be observed. A Generalized Development Plan (GDP) has
been submitted as a proffered exhibit. The GDP identifies the general road layout.
(Reference Attachment 4. Generalized Development Plan Exhibit for Russell 150)
The conjunction of three major new thoroughfares on this property provides opportunities for
this site to be a focal point for alternative modes of transportation. Interconnecting trip
loops, with destinations including but not limited to the Winchester Regional Airport,
Shenandoah University main campus, south Winchester existing and developing retail and
employment uses, the Virginia Employment Commission, and a variety of residential
communities could support alternative modes of transportation. These transportation modes
include shuttle bus mass transit, bicycle, and pedestrian. The City of Winchester transit
system and others involved in regional transportation programs may have an interest in bus
stop shelters within this project.
Flood Plains
The subject property can be found on FEMA NFIP map #510063 0115 -B. The bottomland
along Buffalo Lick Run and two small areas of branching unnamed tributaries is identified as
File #3701/EAW /ajc 4
Greenway Engineering November 3, 2004 Russell 150 Rezoning
Revised January 24, 2005
being within the 100 -year floodplain (or "base flood in designated "Zone A The
remainder of the site is located outside the 100 -year floodplain in designated "Zone C
The land within the 100 -year floodplain (FEMA designated "Zone A is, and will remain,
concurrently designated Frederick County zoning overlay district FP (Floodplain) District
with the surrounding base zoning district. Any disturbance of this area will be in
conformance with Army Corps of Engineers and Department of Environmental Quality
permitting procedures.
A Road crossing of Buffalo Lick Run floodplain will be required for Warrior Drive. Except
for this Warrior Drive right -of -way, the floodplain will be designated and protected as
permanent open space. The main body of the Buffalo Lick Run floodplain will be included
in a public park. The park will not only maintain the functioning of the floodplain, but also
provide an opportunity to educate the public concerning the value of stream valley
ecosystems.
Wetlands
There are no wetlands designated on this site within the Frederick County GIS database.
However there is an area that may contain hydrotropic plant species. The property will
undergo a detailed wetland study and any wetlands identified will be addressed
appropriately. The applicant shall comply with any requirement for Virginia Department of
Environmental Quality permits.
Soil Types
The soil types contained in this tract have been obtained from the Frederick County GIS
database. (Reference Attachment 2. Existing Soils Exhibit for Russell Farm) The subject site
contains the following eight soil types:
1B Berks channery silt loam
3B Blairton silt loam
6C Carbo- Oaklet silt loam, very rocky
9B Clearbrook channery silt loam
9C Clearbrook channery silt loam
14B Frederick Poplimento loams
28 Lobdell silt loam
32B Oaklet Silt Loam
4IC Weikert -Berks channery silt loam
41D Weikert-Berks channery silt loam
41E Weikert-Berks channery silt loam
2 -7 slope
2 -7 slope
2 -15 slope
2 -7 slope
7 -15 slope
2 -7 slope
flood plain
2 -7% slope
7 -15 slope
15 -25 slope
25 -65 slope
covers approximately 1 of site
covers approximately 7 of site
covers approximately 1 of site
covers approximately 29 of site
covers approximately 5 of site
covers approximately 9 of site
covers approximately 3 of site
covers approximately 1% of site
covers approximately 3 of site
covers approximately 22 of site
covers approximately 19 of site
Table 5 on page 123 of The Soil Survey of Frederick County, Virginia, identifies the 3B
Blairton Silt loam and 28 Lobdell silt loam soils as prime farmland. The remaining soil types
on site are not identified within this table.
File #3701/EAWlajc 5
Greenway Engineering November 3, 2004 Russell 150 Rezoning
Revised January 24, 2005
Other Environmental Features
Riparian buffers, measured thirty -five feet from the channel scar line, will be provided along
the length of Buffalo Lick Run. For the most part these riparian buffers are within the area
also designated floodplain.
Although the slopes on the property are not designated by the Frederick County Zoning
Ordinance as steep slope "exceeds 50 the applicant recognizes there are slopes adjacent
to the stream valley that should be protected and so they are being included in common open
space. Likewise, wooded areas within the stream valley and associated slopes will be
protected in common open space.
The applicant is designing this project to do more than simply protect the environmental
features of the site. The design is intended to enhance the community's appreciation of this
stream valley ecosystems as surrounding properties urbanize. Should the Winchester
Frederick County Park Authority wish to accept, the applicant would consider proffering the
dedication of approximately ten acres of common open space to create a Buffalo Lick Run
linear trail Park.
B. SURROUNDING PROPERTIES
Adjoining property zoning and present use:
North: RP (Residential Performance) District Use: Residential
B2 (Business General) District Use: Commercial
South: RA (Rural Areas) District Use: Agriculture
East: RP (Residential Performance) District Use: Residential
West: City of Winchester Use: I -81 /future Commercial
C. TRANSPORTATION
This application proposes the proffered rezoning for 440,450 square feet of commercial retail
uses, 264,000 square feet of office uses and 294 attached single family residential units on a
150.28 site. Traffic will primarily access the site via the proffered future alignments and
intersections of Warrior Drive, Airport Road extended, and East Tevis Street. These planned
major thoroughfares will provide inter connections to properties located to the north, east,
west, and south. The Interstate -81 Flyover for the East Tevis Street and related roadways are
being funded through a unique special taxing district. These roadways are addressed in the
Proffers and depicted in the Generalized Development Plan.
File #3701/EAW /aje 6
Gieenway Engineering November 3, 2004
Revised January 24, 2005
Russell 150 Rezoning
This property is the site of significant portions of the alignment and the intersections of three
major planned roadways. These roadways are Warrior Drive, Airport Road extended, and
East Tevis Street. In theory, the County could attempt to acquire the necessary rights -of -way
for the regional roadways outside of the property -owner initiated land development process.
Fortunately instead, there is a willing property owner who will dedicate the necessary right
of -way as a function of a rezoning application. The proffer of these vital transportation links
is well timed for the prosperity of local businesses and the traveling public's convenience, in
both Frederick County and the City of Winchester.
The Winchester Area Transportation Study (WATS) indicates Warrior Drive, the Airport
Road extended, and the East Tevis Street should all be four -lane urban design facilities.
Portions of these roadways are to be median divided sections, although Warrior Road is to
transition to an undivided section at some point near the southern boundary of this property.
VDOT has stated the Warrior Drive and East Tevis Street rights -of -ways should be a
minimum 120 feet wide. VDOT also would like to have an innovative but land- consuming
roundabout at the intersection of Warrior Road and Airport Drive extended. The Warrior
Drive stream crossing and East Tevis Street overpass must have adequate width to
accommodate bicycle lanes.
The applicant is willing to reserve approximately 19.25 acres (approximately 500 linear feet
of predominately 120 foot wide right -of -way and a roundabout) of this property for collector
and arterial roads. The applicant's dedication of this substantial quantity of land represents a
contribution of significant economic value. The establishment of major roadways is one of
the more visible forms of public infrastructure that support development on a site such as
this. On one hand we acknowledge the presence of these roadways will enhance the value of
the subject property. On the other hand, it should be conceded that these roads are, in great
part, needed to accommodate existing and planned growth outside of this site.
In recognition of the singular opportunity to create community character provided by three
new major thoroughfares intersecting on this site, the applicant proffer covenants of key
public space design elements. The three major thoroughfares are all to be four -lane road
sections, with curb, gutter, and storm drains. Sidewalks, separated from the curb by a grass
utility strip, are to be provided on both sides of these streets. The roadways, including the
roundabout, are to be landscaped with appropriate street trees. Properties fronting on these
streets will be landscaped with corresponding trees. The private properties immediately
surrounding the roundabout will also be subject to special treatment intended to enhance the
visual presence of this road feature. The street lighting will be of a unified architectural
style.
A Traffic Impact Analysis (TIA) has been prepared for the 150.28 -acre site by Patton Harris
Rust and Associates, which is dated November 1, 2004 and is included in the Impact
Analysis Statement. The TIA assumes the total build out of 294 attached single family
residential units, 264,000 square feet of office uses, and 440,450 square feet of retail uses by
the year 2010. The TIA provides for a Level of Service (LOS) analysis, AM and PM peak
hour traffic volumes and Average Daily Trip volumes for existing, background, and build out
conditions. The TIA concludes the traffic impacts associated with the proposed Russell 150
development are acceptable and manageable. All of the intersections analyzed will operate at
File #3701 /EAW /ajc 7
Greenway Engineering November 3, 2004 Russell 150 Rezoning
Revised January 24, 2005
levels of service "C" for 2010 background and build -out conditions, except for the Route 522
and I -81 ramp/Route 17/50 intersection which currently operates at levels of service "F
The applicant will provide the dedication of approximately 19.25 acres for major
thoroughfares, as well as frontage improvements to Front Royal Pike, to facilitate safe
ingress and egress and to mitigate impacts of this development. These improvements are to
include a right turn lane on Front Royal Pike. All improvements are incorporated into the
proffer statement for this project. Road efficiency buffers of fifty feet will separate the
residential lots from Front Royal Pike and Warrior Drive.
The Frederick County Bicycle Plan is depicted on page 7 -17 of the Comprehensive Policy
Plan. The bicycle plan indicates a "proposed designation" of a bicycle route connecting the
Front Royal Pike and Airport Road intersection with an alignment that appears to follow the
planned Warrior Drive all the way through to Fairfax Pike (Route 277). Due to the fact the
Airport Road extended and Warrior Road projects have not yet been engineered, bicycle
lanes can be included in the design. Furthermore, the East Tevis Street may be the best
chance for establishing an 1 -81 crossing on the bicycle route system. The applicant proffers
bicycle facilities parallel to Warrior Drive, Airport Road extended, and East Tevis Street.
D. SEWAGE CONVEYANCE AND TREATMENT
The 150.28 -acre property is located within the Urban Development (UDA) and Sewer and
Water Service Area (SWSA) boundaries. There are existing 8" sanitary sewer lines serving
the adjacent homes on Front Drive and Royal Avenue. There is also an 8" sewer line on the
on the east side of Front Royal Pike, running from roughly Airport Road to Buffalo Lick
Run. The principle collector lines for the development's sanitary sewer system will probably
follow the topography to the Buffalo Lick Run floodplain, then under Front Royal Pike, and
on to the 522 Sewage Pumping Station #1. It will be connected to the main in accordance
with Frederick County Sanitation Authority (FCSA) regulations.
Impacts of the proposed rezoning on the sewage conveyance and treatment system can be
projected based on the proffered land uses of 704,450 square feet of combined commercial
uses (440,450 square feet of retail and 264,000 square feet of office) and 294 attached single
family dwelling units. The FCSA design figures estimate 500 gallons per day (GPD) per
acre of general commercial development, and 225 gallons per day (GPD) per attached single
family dwelling unit.
The figures below represent the impact that this project would have to the sewage
conveyance system and treatment system at full build -out of 440,450 square feet of
commercial:
Q 500 GPD of general commercial development
Q 500 GPD a approximately 96 acres
Q 48,000 GPD projected at total commercial build out
File #3701/EAW /aje 8
Greenway Engineering November 3, 2004
Revised January 24, 2005
Russell 150 Rezoning
The figures below represent the impact that this project would have to the sewage
conveyance system and treatment system at full build -out of 294 dwelling units:
E. WATER SUPPLY
Q 225 GPD per dwelling unit
Q 225 GPD x 294 dwelling units
Q 66,150 GPD projected at total residential build out
COMBINED COMMERCIAL RESIDENTIAL Q 114,150 GPD
The proposed zoning is projected to increase flows to the public sewage conveyance system
and the Opequon Wastewater Treatment Plant by 114,150 GPD at total build out. The design
capacity of the treatment plant is 8.4 million GPD, of which approximately 6.4 GPD is
currently being utilized. The total build -out of the proffered land uses would require
approximately 5.7 percent of the available capacity at the Opequon Waste Water Treatment
Plant; therefore, adequate capacity is available for this development.
The 150.28 -acre property is located within the Urban Development Area (UDA) and Sewer
and Water Service Area (SWSA) boundaries. There is an existing 20 -inch water main
running along the property line (a.k.a. right -of -way line) the subject property shares with
Front Royal Pike. This 20 -inch main is a major transmission line from the James Diehl
Water Treatment Plant.
Impacts of the proposed rezoning on the water supply system can be projected based on the
proffered land use of 704,450 square feet of combined commercial uses (440,450 square feet
of retail and 264,000 square feet of office) and 294 attached single family dwelling units.
Design figures for comparable projects estimate 125 GPD per 1,000 square feet of
commercial, and 275 GPD per attached single family dwelling unit.
The figures below represent the impact that this project would have to the public water
system at full build -out of 440,450 square feet of commercial:
Q 125 GPD per 1,000 commercial square foot
Q 125 GPD x 704.45 (1,000 commercial square feet)
Q 88,056.25 GPD projected at total commercial build out
The figures below represent the impact that this project would have to the public water
system at full build -out of 294 dwelling units:
Q 275 GPD per dwelling unit
Q 275 GPD x 294 dwelling units
Q 80,850 GPD projected at total residential build out
The proposed zoning is estimated to draw 168,906.25 gallons per day from the public water
supply system. The James Diehl Water Treatment Plant is one of three sources contributing
File #3701/EAW /ajc 9
Greenway Engineering November 3, 2004
Revised January 24, 2005
Russell 150 Rezoning
to the blended water serving the area of this property. This treatment plant provides
approximately 4 million gallons per day of potable water. The projected water usage at
build -out would account for less than five percent of this portion of the blended sources.
Adequate capacity is available for this development.
F. SITE DRAINAGE
The 150.28 -acre site generally drains to Buffalo Lick Run and then downstream under Front
Royal Pike (Route 522). Preliminary engineering indicates the use of storm water
management ponds in the main draws into Buffalo Lick Run. The on -site storm water
management facilities will be designed to ensure that the post- development release into
Buffalo Lick Run does not exceed the pre- development conditions. Stormwater management
design will occur during the site development process, which will require approval by the
Frederick County Engineer and Virginia Department of Transportation. The design of the
stormwater management facilities will be implemented in a manner that will avoid any
disturbance of the existing stream and any associated wetlands. Consideration will be given
to the use of oil separators or other BMP's to minimize the impact from parking areas and
other impervious surfaces.
The natural drainage ways of this site present a superb opportunity for the crafting of an open
space amenity. Over the last century or so, those who have farmed the property have been
inclined to maintain the stream valley and adjoining slopes in a relatively natural state.
Therefore the beauty of a wooded stream, and the wildlife habitat it provides, has been
preserved. Now, aided by the statutory protections of designated floodplain, land planners
can continue this tradition. The applicant proffers to place this stream valley, from the
floodplain to the associated slopes, in approximately ten acres of common open space.
G. SOLID WASTE DISPOSAL
An estimate of the aggregate impact of the potential commercial and residential uses on solid
waste disposal facilities can be projected based upon average annual business and attached
single family residential waste generation. According to the Civil Engineering Reference
Manuel, 4 Edition, annual average volume (AV) of business consumption of landfill space
is 5.4 cubic yards per 1,000 square feet of structural area. Each household unit has an annual
average volume (AV) of 5.4 cubic yards of landfill volume (Civil Engineering Reference
Manual, 4 Edition). The following figures show the increase in daily volume based on the
proffered density of 440,450 square feet of commercial use and 294 dwelling units.
AV 5.4 cu. yd. per 1,000 sq ft commercial
AV 5.4 cu. yd.. 704.45 units (of 1,000 sq ft commercial)
AV 3,804.03 cu yd at build -out
AV 5.4 cu. yd. per dwelling
AV 5.4 cu. yd. x 294 dwellings
AV 1,587.60 cu. yd.
File #37011EAWlaic 10
Greenway Engineering November 3, 2004 Russell 150 Rezoning
Revised January 24, 2005
The Municipal Solid Waste area of the Regional Landfill has a current remaining capacity of
13,100,000 cubic yards (13.1 million cu. yd.), currently being consumed at an average of
200,000 tons per year. This capacity is more than adequate to accommodate the solid waste
generated from this project.
H. HISTORICAL SITES AND STRUCTURES
The Russell Farm, taken as a whole with the farmhouse, outbuildings, and most importantly,
the surrounding farmland is identified in the Frederick County Rural Landmarks Survey as a
potentially significant property. The property is identified as "Russell Place file #34 -431.
The Virginia Division of Historic Landmarks survey form indicates that neither the house nor
any of the outbuildings, though all well maintained, are of substantial historic significance
individually. Instead the farmland, with the cluster of farm buildings taken in this context, is
what is significant. The survey refers to this farm as one of the last examples near
Winchester of a sort of land use that was once "typical" all around the city. However, the
coming of the road improvements envisioned by the Comprehensive Policy Plan will forever
change this farmland context and greatly reduce the property's historic significance.
"Russell Place file #34 -431, is the only historic feature in the immediate vicinity
inventoried by the Virginia Division of Historic Landmarks. The property is not identified as
being within the core area of a Civil War battlefield. We are not aware of any archeological
artifacts being found on the site. The application is to be considered by the Historic
Resources Advisory Board (HRAB) at their February 15, 2005 meeting.
I. OTHER IMPACTS
The Frederick County Capital Facilities Fiscal Impact Model has been applied to the
proffered development of 440,450 square feet of commercial retail, 264,000 square feet of
office uses and 294 attached single family dwelling units. The results of this model run
indicate that the development of the subject site will result in a positive total net fiscal impact
of $93,667 +$100,449 per square foot of commercial use and $6,782 per dwelling unit).
Although the model run indicates a substantial positive net fiscal impact, the applicant has
proffered an additional $10,000 to fire and rescue services. The applicant have proffered a
monetary contribution that exceeds that indicated by the results of the fiscal model run in
order to assist the first responder company that will provide service to the Russell 150
community. (Reference Attachment 3. Frederick County Capital Facilities Fiscal Impact
Model for Russell Farm)
The subject property lies within the Winchester Airport five -mile zone of influence and
across Front Royal Pike from the airport support area. The applicant support the requirement
that no use or structure shall be permitted which obstructs the airspace required for the flight
of aircraft in landing or takeoff at such airport or is otherwise hazardous to such landing and
takeoff of aircraft. No additional impacts to community facilities are anticipated by this
rezoning application.
File #3701/EAW /ajc 11
Greenway Engineering
Attachments:
November 3, 2004
Revised January 24, 2005
1. Location and Existing Zoning Exhibit for Russell 150
2. Existing Soils Exhibit for Russell 150
3. Frederick County Capital Facilities Fiscal Impact Model for Russell 150
4. Generalized Development Plan Exhibit for Russell 150
5. Traffic Impact Analysis for Russell 150
6. Conditional Zoning Proffer Statement for Russell 150
Russell 150 Rezoning
File #3701/EAW/ajc 12
Lr
i Tc
9618%6 8fr-
113—BERKS CHANNERY SILT LOAM
1C BERKS CHANNERY SILT LOAM
3B— BLAIRTON SILT LOAM
3C BLAIRTON SILT LOAM
6C CARBO OAKLET SILT LOAMS
BC CHILHOWIE SILTY CLAY LOAM
9B— CLEARBROOK CHANNERY SILT LOAMS
9C CLEARBROOK CHANNERY SILT LOAM
14B— FREDERICK POPLIMENTO LOAMS
28— LOBDELL SILT LOAM
29— MASSANETTA LOAM
La 32B— OAKLET SILT LOAM
35 PACEBROOK SILTY CLAY LOAM
41C— WEIKERT —BERKS CHANNERY SILT LOAMS
41D— WEIKERT —BERKS CHANNERY SILT LOAM
41E— WEIKERT —BERKS CHANNERY SILT LOAM
44B —ZOAR SILT LOAM
L
F
U
I
r, a o
P
2 6 Z
A Q
Cd
O
N N U
N Z a U
p w EN 4 9
CC 3 CE
a
Z
CO
DATE 04 /01 /05
SCALE r 200•
ZONING LEGEND
1
RA
RP
R4
R5
MH1
81
82
B3
MI
M2
EM
HE
RURAL AREAS DISTRICT
RESIDENTIAL PERFORMANCE DISTRICT
RESIDENTIAL PLANNED COMMUNITY
RESIDENTIAL RECREATIONAL COMMUNITY
MOBILE HOME COMMUNITY DISTRICT
NEIGHBORHOOD BUSINESS DISTRICT
BUSINESS GENERAL DISTRICT
INDUSTRIAL TRANSITION DISTRICT
LIGHT INDUSTRIAL DISTRICT
INDUSTRIAL GENERAL DISTRICT
EXTRACTIVE MANUFACTURING DISTRICT
HIGHER EDUCATION DISTRICT
LR
MR
HR
HR- 1
R0 -1
RB- 1
B -I
B -2
CM -1
M -1
M -2
HS
ISECIII MC
HE -1
ESEDEIDESEZZA El P
P110
PMH
PSC
UITY LUNL!NU 1J1 IKLULS
LOW DENSITY RESIDENTIAL DISTRICT
MEDIUM DENSITY RESIDENTIAL DISTRICT
HIGH DENSITY RESIDENTIAL DISTRICT
LIMITED HIGH DENSITY RESIDENTIAL DISTRICT
RESIDENTIAL OFFICE DISTRICT
RESIDENTIAL BUSINESS DISTRICT
CENTRAL BUSINESS DISTRICT
HIGHWAY COMMERCIAL DISTRICT
COMMERCIAL INDUSTRIAL DISTRICT
LIMITED INDUSTRIAL DISTRICT
INTENSIVE INDUSTRIAL DISTRICT
HEALTH SERVICE DISTRICT
MEDICAL CENTER DISTRICT
HIGHER EDUCATION DISTRICT
EDUCATIONAL. INSTITUTIONAL, PUBLIC DISTRICT
PLANNED UNIT DEVELOPMENT DISTRICT
PLANNED MOBILE HOME DISTRICT
PLANNED SHOPPING CENTER DISTRICT
HISTORIC WINCHESTER DISTRICT
F
0
O
DATE 04 /01/05
SCALE: r 800•
1
A Traffic Impact Analysis of the
Russell Farm
Located in:
Frederick County, Virginia
Prepared for:
I
I
Prepared by:
Greenway Engineering
151 Windy Hill Lane
Winchester, VA
22606
1 Patton Harris Rust Associates, pc
Engineers. at rveyors. Flanners. Landscape Architects.
208 Church Street, SE
Leesburg, Virginia 20175
I PT '1' T703.777.3616
F 703.777.3725
1
1 November 1, 2004
1
1
OVERVIEW
Report Summary
Patton Harris Rust Associates, pc (PHR +A) has prepared this document to
present the traffic impacts associated with the proposed Russell Farm development located
along the west side of Route 522 (Front Royal Pike), between Peppermill Road and Route
17/50, in Frederick County, Virginia. The proposed project is to include 294 townhouse
units, 264,000 square feet of office and 440,450 square feet of retail with primary access to
be provided via the proposed western leg of Airport Road and secondary access
(townhouse only) to be provided via a site driveway located to the south of Airport Road.
The proposed development will be built -out by the year 2010. Figure 1 is provided to
illustrate the location of the Russell Farm site with respect to the surrounding roadway
network.
Methodology
The traffic impacts accompanying the Russell Farm development were obtained
through a sequence of activities as the narratives that follow document:
Assessment of background traffic including other planned projects in the area of
impact,
Calculation of trip generation for Russell Farm,
Distribution and assignment of Russell Farm generated trips onto the study area road
network,
Analysis of capacity and level of service using the newest version of the highway
capacity software, HCS -2000, for existing and future conditions.
EXISTING CONDITIONS
Patton Harris Rust Associates, pc (PHR +A) obtained AM and PM peak hour
manual turning movement counts at the intersections of Papermill Road (Route
644)/Pleasant Valley Road, Papermill Road/Route 522 (Front Royal Pike), Airport
Road/Route 522 and Route 522/Route 50/17 (Millwood Pike). Additionally, 24 -hour
automatic "tube" counts were conducted along the Papermill Road and Route 522,
respectively. PHR +A established the ADT (Average Daily Traffic) along each of the study
area roadway links using an average "k" factor (the ratio of PM peak hour traffic volumes
to 24 -hour traffic volumes) of 8% as determined from traffic count data provided by the
Virginia Department of Transportation (VDOT). Figure 2 shows the existing ADT and
AM/PM peak hour traffic volumes at key locations throughout the study area. Figure 3
shows the respective existing lane geometry and AM/PM peak hour levels of service. All
traffic count data and HCS -2000 levels of service worksheets are included in the Appendix
section of this report.
A Phased Traffic Impact Analysis of the Russell Farm
November 1, 2004
Page 1
Vicinity Map Russell Farms
A Phased Traffic Impact Analysis of the Russell Farm
November 1, 2004
Page 2
1
1
1
1
H
Figure 2
Existing ADT and AM/PM Peak Hour Traffic Volumes
PHR
A Phased Traffic Impact Analysis of the Russell Farm
November I, 2004
Page 3
No Scale
Figure 3
P
Signalized
Intersection
LAS =B(C)
ke 41f
ttr
Signalized
Intersection
LOS =C(F)
-7'" t s Signalized
b u Intersection
km,. LOS =B(B)
r BB)
STTE �c'
Jl t
tt
Signalized
Intersection
LOS=B(B)
5L Y
1 4
UnsIgnaazed
4:\ Intersection
Denotes Unsignalized Critical Movement
AM Peak Hour (PM Peak Hour)
Existing Lane Geometry and Levels of Service
A Phased Traffic Impact Analysis of the Russell Farm
November 1,2004
Page 4
No Scale
Signalized
Intersection
LOS =C(D)
'wad (7) 4!
m e�
Signalized'
Intersection
LOS=B(B)
c(c)
p H RA
F Figure 5
'.Signalized.'
Intersection
LOS =B(C).
Roadway
Improvements
Required
Signalized
Intersection
LOS =D(F)
R
Signalized'.
Intersection Roadway
LoS=B(Bj-. Improvements
Required
Unsignalized
*1 'OD. Intersection
P,
i
11
(B)6
Signalized
lntenection
LOS (B)
Denotes Unsignalized Critical Movement
AM Peak Hour (PM Peak Hour)
2010 Background Lane Geometry and Levels of Service
A Phased Traffic Impact Analysis of the Russell Farm
November 1, 2004
Page 8
No Scale
'`124(228)
59(86)
X102(176)
AM Peak Hour(PM Peak Hour)
q„` Average. Dai lcirritiM
-PHIA
Figure 8 2010 Build -out ADT and AM/PM Peak Hour Traffic Volumes
P
A Phased Traffic Impact Analysis of the Russell Farm
November 1, 2004
Page 12
No Scale
Signalized Roadway
Improvements
ILO§Lt(C) 2 Required
Regional
Improvements
Required
m
s
��Slgvalized
Intersection LOS -Ced
a'
D
P
X11
e
Jill
(qB
ui
Signalized'
Intersecdon
LOS •B(C)
t C(C)
)nr
Airport
Road
Signalized
iatersecdon
LOS -001)
Nit
MI 4
Signalized
Intersection
LOS =C(C)
Signalized
Intersection
LOS =D(i)
rie Roadviay c doa
Inter s e tt
err`ec
ti os=e(sj Improvements
Required
Unslgnailzed
h (°),Intersection
Denotes Unsignalized Critical Movement
AM Peak Hour (PM Peak Hour)
-P
Figure 9 2010 Build -out Lane Geometry and Levels of Service
P
A Phased Traffic Impact Analysis of the Russell Farm
November 1, 2004
Page 13
CONCLUSION
The traffic impacts associated with the proposed Russell Farm development are
acceptable and manageable. The following describes the future operating conditions at
each of the study area intersections.
Route 522 and I -81 ramp/Route 17/50: For existing, 2010 background and build
out conditions, this intersection will operate with levels of service "F This
intersection requires regional roadway improvements to achieve acceptable levels
of service.
Route 17/50 and Ryco Lane: For 2010 background and build -out conditions, this
intersection will operate with levels of service "C" during the AM/PM peak hours.
Traffic signalization, however, would be required to satisfy levels of service
requirements. A signal warrant study would be necessary prior to installation.
Airport Road and Route 522: For 2010 background and build -out conditions, this
intersection will operate with levels of service "C" during the AM and PM peak
hours. Airport Road is proposed to be extended to the site west of Route 522. The
required intersection improvements assumed include a northbound left-turn lane
and southbound right turn lane.
Papermill Road and Route 522: For 2010 background and build -out conditions,
this intersection will operate with levels of service "C" during the AM and PM
peak hours.
Papermill Road and Pleasant Valley Road: For 2010 background and build -out
conditions, this intersection will operate with levels of service "C" during the AM
and PM peak hours. The required intersection improvements assumed include a
northbound left-turn lane and southbound right -turn lane.
A Phased Traffic Impact Analysis of the Russell Farm
November 1, 2004
Page 14
File #370I/EA W /ajc
IMPACT STATEMENT
RUSSELL 150
REZONING
Shawnee Magisterial District
Frederick County, Virginia
TM 64- ((A)) -10 64- ((A)) -12
150.28 -Acres
November 3, 2004
revised January 24, 2005
Current Owners: Russell 150, LC
Applicant: Russell 150, LC
Contact Person: Mark Smith, PE LS
Greenway Engineering
151 Windy Hill Lane
Winchester, VA 22602
540- 662 -4185
Greenway Engineering
INTRODUCTION
Basic information
Location:
Magisterial District:
Property ID Numbers:
Current Zoning:
Current Use:
Proposed Use:
Proposed Zoning:
Total rezoning area:
Proposed build -out
November 3, 2004
Revised January 24, 2005
RUSSELL 150 REZONING
Russell 150 Rezoning
This report has been prepared for the purpose of assessing the impact on Fredrick County by
the proffered rezoning of a 150.28 -acre subject property identified as Russell 150 and owned
by Russell 150, LC. The subject property consists of two parcels, those being: TM 64- ((A))-
10; 29.97 acres, and 64- ((A)) -12; 120.31 acre. The subject site is located on the west side of
Front Royal Pike (Route 522), opposite Airport Road (Route 645). The property is traversed
by the future alignments and intersections of three major thoroughfares. The current zoning
is Rural Areas (RA) District. The applicant, Russell 150, LC proposes to rezone the parcel
from Rural Areas (RA) to Business General (B2) District and Residential Performance (RP)
District. (Reference Attachment 1. Location and Existing Zoning Exhibit for Russell 150)
Fronting on the west side of Front Royal Pike (Route
522), opposite Airport Road (Route 645)
Shawnee
64- ((A)) -10 and 64- ((A)) -12
Rural Areas (RA) District
Agricultural, Unimproved
Commercial, Office and Retail
Residential, Attached single- family
Business General (B2) District and
Residential Performance (RP) District
150.28 acres
440,450 square feet commercial retail
264,000 square feet office
294 residential attached single- family units
File #3701/EAW /ajc 2
Greenway Engineering November 3, 2004
Revised January 24, 2005
COMPREHENSIVE PLAN
Russell 150 Rezoning
The subject property is located wholly within the Sewer and Water Service Area (SWSA)
and Urban Development Area (UDA). No expansion of the SWSA or UDA is required for
development of the subject property.
The property is also included in the study area boundary of the Route 50 East Corridor Land
Use Plan. The Comprehensive Policy Plan 1999, Route 50 East Corridor Land Use Plan
states on page 6 -19:
An area of business /office use is also shown west of the intersection of Airport Road
and Route 522. This area would be expected to accommodate a future road
connection resulting from the extended of Airport Road, west into the City. Plans at
this time would be to connect with road segments which are, at this time, partially in
place south of Lowes, extending east from Pleasant Valley Road. This connection is
seen as an important link in the overall Winchester Area Transportation Plan.
The Comprehensive Policy Plan, Eastern Road Plan, page 7 -15 and the Winchester Area
Transportation Study (WATS) depict "new major collectors" of Warrior Drive and Airport
Road extended crossing and intersecting on the subject property. In further refinements of
these plans, VDOT has stated a desire for East Tevis Street to be the through movement in
the Warrior Drive intersection, and Airport Road to connect Warrior Drive with a roundabout
intersection. The roadways proffered through the generalized development plan are in
conformance with these comprehensive planning documents.
The Frederick County Bicycle Plan is depicted on page 7 -17 of the Comprehensive Policy
Plan. The bikeways, discussed further in the Transportation section of this report, and
proffered through the generalized development plan, is in substantial conformance with the
Comprehensive Policy Plan.
The subject property north of Buffalo Lick Run and west of Warrior Drive is to be developed
in business /office uses, in complete conformity with the Comprehensive Policy Plan, Route
50 East Corridor Land Use Plan. The Buffalo Lick Run stream valley forms a natural buffer
and dividing line between these business /office uses and residential uses to the south. The
Comprehensive Policy Plan 1999, Route 50 East Corridor Land Use Plan graphic on page 6-
21 shows exactly that, with a bubble labeled "proposed business /office" above a line
identified as "urban development area" and "corridor boundary corresponding to that
labeled Buffalo Lick Run. The single land bay situated south of the Buffalo Lick Run stream
valley, between Front Royal Pike (Route 522) to the east and Warrior Drive to the west, is to
be developed in a residential use. This residential land bay comprises approximately twenty
five percent of the total project area. The proposed residential use of this land bay is in
substantial conformance with the Comprehensive Policy Plan, and is in keeping with
principles of good planning.
File #3701/EAW /ajc 3
Greenway Engineering November 3, 2004
Revised January 24, 2005
1. Urban Development Area
Russell 150 Rezoning
Expansion of the Urban Development Area (UDA) beyond its existing boundary is not
required by this application.
2. Sewer and Water Service Area
Expansion of the Sewer and Water Service Area (SWSA) beyond its existing boundary is not
required by this application.
A. SUITABILITY OF THE SITE
Access
The subject site, consisting of tax parcels 64- ((A)) -10 and 64- ((A)) -12, is located within a
manmade boundary created by Front Royal Pike (Route 522) on the eastern frontage of the
property and I -81 along the western side.
Access to the various land bays within the subject site will generally be from the planned
major thoroughfares of Warrior Drive, Airport Road extended, and East Tevis Street. The
subject property has approximately 220 feet of frontage on Front Royal Pike (Route 522).
Airport Road extended will create a four -way intersection with Front Royal Pike. The
residential land bay will have a single connection to Front Royal Pike, and a single entrance
on Warrior Drive. It is noted that no individual commercial lot access is proposed from
Front Royal Pike. Safe entrance separation distances from the roundabout and other major
thoroughfare intersections will be observed. A Generalized Development Plan (GDP) has
been submitted as a proffered exhibit. The GDP identifies the general road layout.
(Reference Attachment 4. Generalized Development Plan Exhibit for Russell 150)
The conjunction of three major new thoroughfares on this property provides opportunities for
this site to be a focal point for alternative modes of transportation. Interconnecting trip
loops, with destinations including but not limited to the Winchester Regional Airport,
Shenandoah University main campus, south Winchester existing and developing retail and
employment uses, the Virginia Employment Commission, and a variety of residential
communities could support alternative modes of transportation. These transportation modes
include shuttle bus mass transit, bicycle, and pedestrian. The City of Winchester transit
system and others involved in regional transportation programs may have an interest in bus
stop shelters within this project.
Flood Plains
The subject property can be found on FEMA NFIP map #510063-0115-B. The bottomland
along Buffalo Lick Run and two small areas of branching unnamed tributaries is identified as
File #3701/EAW /ajc 4
Greenway Engineering November 3, 2004 Russell 150 Rezoning
Revised January 24, 2005
being within the 100 -year floodplain (or "base flood in designated "Zone A The
remainder of the site is located outside the 100 -year floodplain in designated "Zone C
The land within the 100 -year floodplain (FEMA designated "Zone A is, and will remain,
concurrently designated Frederick County zoning overlay district FP (Floodplain) District
with the surrounding base zoning district. Any disturbance of this area will be in
conformance with Army Corps of Engineers and Department of Environmental Quality
permitting procedures.
A Road crossing of Buffalo Lick Run floodplain will be required for Warrior Drive. Except
for this Warrior Drive right -of -way, the floodplain will be designated and protected as
permanent open space. The main body of the Buffalo Lick Run floodplain will be included
in a public park. The park will not only maintain the functioning of the floodplain, but also
provide an opportunity to educate the public concerning the value of stream valley
ecosystems.
Wetlands
There are no wetlands designated on this site within the Frederick County GIS database.
However there is an area that may contain hydrotropic plant species. The property will
undergo a detailed wetland study and any wetlands identified will be addressed
appropriately. The applicant shall comply with any requirement for Virginia Department of
Environmental Quality permits.
Soil Types
The soil types contained in this tract have been obtained from the Frederick County GIS
database. (Reference Attachment 2. Existing Soils Exhibit for Russell Farm) The subject site
contains the following eight soil types:
1B Berks channery silt loam
3B Blairton silt loam
6C Carbo Oaklet silt loam, very rocky
9B Clearbrook channery silt loam
9C Clearbrook channery silt loam
14B Frederick Poplimento loams
28 Lobdell silt loam
32B Oaklet Silt Loam
41C Weikert-Berks channery silt loam
41D Weikert-Berks channery silt loam
41E Weikert-Berks channery silt loam
2 -7 slope
2 -7 slope
2 -15 slope
2 -7 slope
7 -15 slope
2 -7 slope
flood plain
2 -7% slope
7 -15 slope
15 -25 slope
25 -65 slope
covers approximately 1 of site
covers approximately 7 of site
covers approximately 1 of site
covers approximately 29 of site
covers approximately 5 of site
covers approximately 9 of site
covers approximately 3 of site
covers approximately 1% of site
covers approximately 3 of site
covers approximately 22 of site
covers approximately 19 of site
Table 5 on page 123 of The Soil Survey of Frederick County, Virginia, identifies the 3B
Blairton Silt loam and 28 Lobdell silt loam soils as prime farmland. The remaining soil types
on site are not identified within this table.
File ri3701/EAW /ajc 5
Greenway Engineering 1111 November 3, 2004 Russell 150 Rezoning
Revised January 24, 2005
Other Environmental Features
Riparian buffers, measured thirty -five feet from the channel scar line, will be provided along
the length of Buffalo Lick Run. For the most part these riparian buffers are within the area
also designated floodplain.
Although the slopes on the property are not designated by the Frederick County Zoning
Ordinance as steep slope "exceeds 50 the applicant recognizes there are slopes adjacent
to the stream valley that should be protected and so they are being included in common open
space. Likewise, wooded areas within the stream valley and associated slopes will be
protected in common open space.
The applicant is designing this project to do more than simply protect the environmental
features of the site. The design is intended to enhance the community's appreciation of this
stream valley ecosystems as surrounding properties urbanize. Should the Winchester
Frederick County Park Authority wish to accept, the applicant would consider proffering the
dedication of approximately ten acres of common open space to create a Buffalo Lick Run
linear trail Park.
B. SURROUNDING PROPERTIES
Adjoining property zoning and present use:
North: RP (Residential Performance) District Use: Residential
B2 (Business General) District Use: Commercial
South: RA (Rural Areas) District Use: Agriculture
East: RP (Residential Performance) District Use: Residential
West: City of Winchester Use: I -81 /future Commercial
C. TRANSPORTATION
This application proposes the proffered rezoning for 440,450 square feet of commercial retail
uses, 264,000 square feet of office uses and 294 attached single family residential units on a
150.28 site. Traffic will primarily access the site via the proffered future alignments and
intersections of Warrior Drive, Airport Road extended, and East Tevis Street. These planned
major thoroughfares will provide inter connections to properties located to the north, east,
west, and south. The Interstate -81 Flyover for the East Tevis Street and related roadways are
being funded through a unique special taxing district. These roadways are addressed in the
Proffers and depicted in the Generalized Development Plan.
File #370I/EA W /ajc 6
Greenway Engineering November 3, 2004
Revised January 24, 2005
Russell 150 Rezoning
This property is the site of significant portions of the alignment and the intersections of three
major planned roadways. These roadways are Warrior Drive, Airport Road extended, and
East Tevis Street. In theory, the County could attempt to acquire the necessary rights -of -way
for the regional roadways outside of the property -owner initiated land development process.
Fortunately instead, there is a willing property owner who will dedicate the necessary right
of -way as a function of a rezoning application. The proffer of these vital transportation links
is well timed for the prosperity of local businesses and the traveling public's convenience, in
both Frederick County and the City of Winchester.
The Winchester Area Transportation Study (WATS) indicates Warrior Drive, the Airport
Road extended, and the East Tevis Street should all be four -lane urban design facilities.
Portions of these roadways are to be median divided sections, although Warrior Road is to
transition to an undivided section at some point near the southern boundary of this property.
VDOT has stated the Warrior Drive and East Tevis Street rights -of -ways should be a
minimum 120 feet wide. VDOT also would like to have an innovative but land consuming
roundabout at the intersection of Warrior Road and Airport Drive extended. The Warrior
Drive stream crossing and East Tevis Street overpass must have adequate width to
accommodate bicycle lanes.
The applicant is willing to reserve approximately 19.25 acres (approximately 500 linear feet
of predominately 120 foot wide right -of -way and a roundabout) of this property for collector
and arterial roads. The applicant's dedication of this substantial quantity of land represents a
contribution of significant economic value. The establishment of major roadways is one of
the more visible forms of public infrastructure that support development on a site such as
this. On one hand we acknowledge the presence of these roadways will enhance the value of
the subject property. On the other hand, it should be conceded that these roads are, in great
part, needed to accommodate existing and planned growth outside of this site.
In recognition of the singular opportunity to create community character provided by three
new major thoroughfares intersecting on this site, the applicant proffer covenants of key
public space design elements. The three major thoroughfares are all to be four -lane road
sections, with curb, gutter, and storm drains. Sidewalks, separated from the curb by a grass
utility strip, are to be provided on both sides of these streets. The roadways, including the
roundabout, are to be landscaped with appropriate street trees. Properties fronting on these
streets will be landscaped with corresponding trees. The private properties immediately
surrounding the roundabout will also be subject to special treatment intended to enhance the
visual presence of this road feature. The street lighting will be of a unified architectural
style.
A Traffic Impact Analysis (TIA) has been prepared for the 150.28 -acre site by Patton Harris
Rust and Associates, which is dated November 1, 2004 and is included in the Impact
Analysis Statement. The TIA assumes the total build out of 294 attached single family
residential units, 264,000 square feet of office uses, and 440,450 square feet of retail uses by
the year 2010. The TIA provides for a Level of Service (LOS) analysis, AM and PM peak
hour traffic volumes and Average Daily Trip volumes for existing, background, and build out
conditions. The TIA concludes the traffic impacts associated with the proposed Russell 150
development are acceptable and manageable. All of the intersections analyzed will operate at
File #370I/EAW /ajc 7
Greenway Engineering November 3, 2004 Russell 150 Rezoning
Revised January 24, 2005
levels of service "C" for 2010 background and build -out conditions, except for the Route 522
and 1 -81 ramp /Route 17/50 intersection which currently operates at levels of service "F
The applicant will provide the dedication of approximately 19.25 acres for major
thoroughfares, as well as frontage improvements to Front Royal Pike, to facilitate safe
ingress and egress and to mitigate impacts of this development. These improvements are to
include a right turn lane on Front Royal Pike. All improvements are incorporated into the
proffer statement for this project. Road efficiency buffers of fifty feet will separate the
residential lots from Front Royal Pike and Warrior Drive.
The Frederick County Bicycle Plan is depicted on page 7 -17 of the Comprehensive Policy
Plan. The bicycle plan indicates a "proposed designation" of a bicycle route connecting the
Front Royal Pike and Airport Road intersection with an alignment that appears to follow the
planned Warrior Drive all the way through to Fairfax Pike (Route 277). Due to the fact the
Airport Road extended and Warrior Road projects have not yet been engineered. bicycle
lanes can be included in the design. Furthermore, the East Tevis Street may be the best
chance for establishing an I -81 crossing on the bicycle route system. The applicant proffers
bicycle facilities parallel to Warrior Drive, Airport Road extended, and East Tevis Street.
D. SEWAGE CONVEYANCE AND TREATMENT
The 150.28 -acre property is located within the Urban Development (UDA) and Sewer and
Water Service Area (SWSA) boundaries. There are existing 8" sanitary sewer lines serving
the adjacent homes on Front Drive and Royal Avenue. There is also an 8" sewer line on the
on the east side of Front Royal Pike, running from roughly Airport Road to Buffalo Lick
Run. The principle collector lines for the development's sanitary sewer system will probably
follow the topography to the Buffalo Lick Run floodplain, then under Front Royal Pike, and
on to the 522 Sewage Pumping Station #l. It will be connected to the main in accordance
with Frederick County Sanitation Authority (FCSA) regulations.
Impacts of the proposed rezoning on the sewage conveyance and treatment system can be
projected based on the proffered land uses of 704,450 square feet of combined commercial
uses (440,450 square feet of retail and 264,000 square feet of office) and 294 attached single
family dwelling units. The FCSA design figures estimate 500 gallons per day (GPD) per
acre of general commercial development, and 225 gallons per day (GPD) per attached single
family dwelling unit.
The figures below represent the impact that this project would have to the sewage
conveyance system and treatment system at full build -out of 440,450 square feet of
commercial:
Q 500 GPD of general commercial development
Q 500 GPD x approximately 96 acres
Q 48,000 GPD projected at total commercial build out
File #3701/EA W /ajc 8
Greenway Engineering November 3, 2004
Revised January 24, 2005
The figures below represent the impact that this project would have to the sewage
conveyance system and treatment system at full build -out of 294 dwelling units:
E. WATER SUPPLY
Q 225 GPD per dwelling unit
Q 225 GPD x 294 dwelling units
Q 66,150 GPD projected at total residential build out
Russell 150 Rezoning
COMBINED COMMERCIAL RESIDENTIAL Q 114,150 GPD
The proposed zoning is projected to increase flows to the public sewage conveyance system
and the Opequon Wastewater Treatment Plant by 114,150 GPD at total build out. The design
capacity of the treatment plant is 8.4 million GPD, of which approximately 6.4 GPD is
currently being utilized. The total build -out of the proffered land uses would require
approximately 5.7 percent of the available capacity at the Opequon Waste Water Treatment
Plant; therefore, adequate capacity is available for this development.
The 150.28 -acre property is located within the Urban Development Area (UDA) and Sewer
and Water Service Area (SWSA) boundaries. There is an existing 20 -inch water main
running along the property line (a.k.a. right -of -way line) the subject property shares with
Front Royal Pike. This 20 -inch main is a major transmission line from the James Diehl
Water Treatment Plant.
Impacts of the proposed rezoning on the water supply system can be projected based on the
proffered land use of 704,450 square feet of combined commercial uses (440,450 square feet
of retail and 264,000 square feet of office) and 294 attached single family dwelling units.
Design figures for comparable projects estimate 125 GPD per 1,000 square feet of
commercial, and 275 GPD per attached single family dwelling unit.
The figures below represent the impact that this project would have to the public water
system at full build -out of 440,450 square feet of commercial:
Q 125 GPD per 1,000 commercial square foot
Q 125 GPD x 704.45 (1,000 commercial square feet)
Q 88,056.25 GPD projected at total commercial build out
The figures below represent the impact that this project would have to the public water
system at full build -out of 294 dwelling units:
Q 275 GPD per dwelling unit
Q 275 GPD x 294 dwelling units
Q 80,850 GPD projected at total residential build out
The proposed zoning is estimated to draw 168,906.25 gallons per day from the public water
supply system. The James Diehl Water Treatment Plant is one of three sources contributing
File #3701 /EAW /ajc 9
Grccnway Engineering November 3, 2004
Revised January 24, 2005
F. SITE DRAINAGE
Russell 150 Rezoning
to the blended water serving the area of this property. This treatment plant provides
approximately 4 million gallons per day of potable water. The projected water usage at
build -out would account for less than five percent of this portion of the blended sources.
Adequate capacity is available for this development.
The 150.28 -acre site generally drains to Buffalo Lick Run and then downstream under Front
Royal Pike (Route 522). Preliminary engineering indicates the use of storm water
management ponds in the main draws into Buffalo Lick Run. The on -site storm water
management facilities will be designed to ensure that the post development release into
Buffalo Lick Run does not exceed the pre development conditions. Stormwater management
design will occur during the site development process, which will require approval by the
Frederick County Engineer and Virginia Department of Transportation. The design of the
stormwater management facilities will be implemented in a manner that will avoid any
disturbance of the existing stream and any associated wetlands. Consideration will be given
to the use of oil separators or other BMP's to minimize the impact from parking areas and
other impervious surfaces.
The natural drainage ways of this site present a superb opportunity for the crafting of an open
space amenity. Over the last century or so, those who have farmed the property have been
inclined to maintain the stream valley and adjoining slopes in a relatively natural state.
Therefore the beauty of a wooded stream, and the wildlife habitat it provides, has been
preserved. Now, aided by the statutory protections of designated floodplain, land planners
can continue this tradition. The applicant proffers to place this stream valley, from the
floodplain to the associated slopes, in approximately ten acres of common open space.
G. SOLID WASTE DISPOSAL
An estimate of the aggregate impact of the potential commercial and residential uses on solid
waste disposal facilities can be projected based upon average annual business and attached
single family residential waste generation. According to the Civil Engineering Reference
Manuel, 4 Edition, annual average volume (AV) of business consumption of landfill space
is 5.4 cubic yards per 1,000 square feet of structural area. Each household unit has an annual
average volume (AV) of 5.4 cubic yards of landfill volume (Civil Engineering Reference
Manual, 4 Edition). The following figures show the increase in daily volume based on the
proffered density of 440,450 square feet of commercial use and 294 dwelling units.
AV 5.4 cu. yd. per 1,000 sq ft commercial
AV 5.4 cu. yd. x 704.45 units (of 1,000 sq ft commercial)
AV 3,804.03 cu yd at build -out
AV 5.4 cu. yd. per dwelling
AV 5.4 cu. yd. x 294 dwellings
AV 1,587.60 cu. yd.
File #3701/EAW /ajc 10
Greenway Engineering 1 November 3, 2004 1 Russell 150 Rezoning
Revised January 24, 2005
The Municipal Solid Waste area of the Regional Landfill has a current remaining capacity of
13,100,000 cubic yards (13.1 million cu. yd.), currently being consumed at an average of
200,000 tons per year. This capacity is more than adequate to accommodate the solid waste
generated from this project.
H. HISTORICAL SITES AND STRUCTURES
The Russell Farm, taken as a whole with the farmhouse, outbuildings, and most importantly,
the surrounding farmland is identified in the Frederick County Rural Landmarks Survey as a
potentially significant property. The property is identified as "Russell Place file #34 -431.
The Virginia Division of Historic Landmarks survey form indicates that neither the house nor
any of the outbuildings, though all well maintained, are of substantial historic significance
individually. instead the farmland, with the cluster of farm buildings taken in this context, is
what is significant. The survey refers to this farm as one of the last examples near
Winchester of a sort of land use that was once "typical" all around the city. However, the
coming of the road improvements envisioned by the Comprehensive Policy Plan will forever
change this farmland context and greatly reduce the property's historic significance.
"Russell Place file #34 431, is the only historic feature in the immediate vicinity
inventoried by the Virginia Division of Historic Landmarks. The property is not identified as
being within the core area of a Civil War battlefield. We are not aware of any archeological
artifacts being found on the site. The application is to be considered by the Historic
Resources Advisory Board (HRAB) at their February 15, 2005 meeting.
I. OTHER IMPACTS
The Frederick County Capital Facilities Fiscal Impact Model has been applied to the
proffered development of 440,450 square feet of commercial retail, 264,000 square feet of
office uses and 294 attached single family dwelling units. The results of this model run
indicate that the development of the subject site will result in a positive total net fiscal impact
of $93,667 +$100,449 per square foot of commercial use and $6,782 per dwelling unit).
Although the model run indicates a substantial positive net fiscal impact, the applicant has
proffered an additional $10,000 to fire and rescue services. The applicant have proffered a
monetary contribution that exceeds that indicated by the results of the fiscal model run in
order to assist the first responder company that will provide service to the Russell 150
community. (Reference Attachment 3. Frederick County Capital Facilities Fiscal Impact
Model for Russell Farm)
The subject property lies within the Winchester Airport five -mile zone of influence and
across Front Royal Pike from the airport support area. The applicant support the requirement
that no use or structure shall be permitted which obstructs the airspace required for the flight
of aircraft in landing or takeoff at such airport or is otherwise hazardous to such landing and
takeoff of aircraft. No additional impacts to community facilities are anticipated by this
rezoning application.
File #3701/EA W /ajc 11
Greenway Engineering November 3, 2004
Revised January 24, 2005
Attachments:
1. Location and Existing Zoning Exhibit for Russell 150
2. Existing Soils Exhibit for Russell 150
3. Frederick County Capital Facilities Fiscal Impact Model for Russell 150
4. Generalized Development Plan Exhibit for Russell 150
5. Traffic Impact Analysis for Russell 150
6. Conditional Zoning Proffer Statement for Russell 150
Russell 150 Rezoning
File #3701/EAW /ajc 12
L.._....._,. MY RESIDENTIAL PERFORMANCE DISTRICT
R4 RESIDENTIAL PLANNED COMMUNITY
R5 RESIDENTIAL RECREATIONAL COMMUNITY
MHI MOBILE HOME COMMUNITY DISTRICT
B1 NEIGHBORHOOD BUSINESS DISTRICT
02 BUSINESS GENERAL DISTRICT
B3 INDUSTRIAL TRANSITION DISTRICT
MI 'LIGHT INDUSTRIAL DISTRICT
M2 INDUSTRIAL GENERAL DISTRICT
EM EXTRACTIVE MANUFACTURING DISTRICT
HE HIGHER EDUCATION DISTRICT
7
RO -1
B -1
8-2
CM -1
M -L
M -2
HS
NC
tea HE -I
ItIvamosom EIP
PUD
P11H
PSC
LIMITED HIGH DENSITY RESIDENTIAL DISTRICT
RESIDENTIAL OFFICE DISTRICT
RESIDENTIAL BUSINESS DISTRICT
CENTRAL BUSINESS DISTRICT
HIGHWAY COMMERCIAL DISTRICT
COMMERCIAL INDUSTRIAL DISTRICT
LIMITED INDUSTRIAL DISTRICT
INTENSIVE INDUSTRIAL DISTRICT
HEALTH SERVICE DISTRICT
H
CENTER GHERLEDUCATION DISTRICT
PLANNED UN INSTITUTIONAL. DEVELPMENT DISTRICT
DISTRICT
PL4NNED MOBILE O
PLANNED SHOPPING CENTER DISTRICT
HISTORIC WINCHESTER DISTRICT
4 4
CIR:‘ \C\cs1/41/4 z1/4X41/4:11/419 AL.,,,,;:1/44\1/44\.44%kt
at. 14%. .\may\` X:1 Q
X i t
X4 N
•C
KiA
CC
0
LH
41 al im
3 _is Tke
a 3 E
Au
Aa °c
Yi k. y
_c Sc
a& WAR.RIOR,� n L 1
Aft
ee
LAND BAY
1- 81
300.
le
m 1B BERKS CHANNERY SILT LOAM
m 1C BERKS CHANNERY SILT LOAM
3B- BLAIRTON SILT LOAM
m 3C BLAIRTON SILT LOAM
O 6C CARBO OAKLET SILT LOAMS
8C CHILHOWIE SILTY CLAY LOAM
e 9B CLEARBROOK CHANNERY SILT LOAMS
9C CLEARBROOK CHANNERY SILT LOAM
e 14B- FREDERICK POPLIMENTO LOAMS
28-LOBDELL SILT LOAM
m 29 MASSANETTA LOAM
e 32B- OAKLET SILT LOAM
35 PAGEBROOK SILTY CLAY LOAM
e 41C- WEIKERT -BERKS CHANNERY SILT LOAMS
41D- WEIKERT -BERKS CHANNERY SILT LOAM
41E- WEIKERT -BERKS CHANNERY SILT LOAM
44B -ZOAR SILT LOAM
e
PROPERTY
r
D R I v e
.N.
c 84—
ul ((A)) -9 P
B 736 PC 86
MI USE: YAEANT-
7
P %4— ((A))'^18
MA FRED KOROBSKY_
DB 468 PC s
ED: RA. USE: N. OANT
OGne
GNMENT
F
O
L
DATE 09 /19/04
Li
0 2
=c
SCALE r 200'
OUTPUT MODULE
APPU CANT: Russel 150
LAND USE TYPE 9252P
REAL EST VAL 575,871,579
FIRES RESCUE' 6
The ed Rescue Department
Eamena,y Sdmuols
IRdde Srhoala
NW Wools
Perks and Recreation
Put0c tray
Sias ORas
AdmiMsVai0n Building
Ober Miseellaneaus Fz4 Uos
SUBTOTAL
LESS NET FISCAL IMPACT
NET CAP. FACILITES VdPACT
NA Fiscal Impact
Costs ol broad Meer
Requited Contend in
Calla oglibee edam only)
4455.529
81,001,909
5635,596
5703,402
4354681
562,385
534.923
547,384
560,451
53,392.620
523.064,80
IN0E2: '1.r II Cap Equip 11411d€111 1.0
HOOD "1.1)* Y Rev-Cost Bel 'O.D"U Rego to Co Avg: 0.0 RevCcat Dal 1.000
PLANNING DEPT PREFERENCES 4.0 1.0 Ratio to Co Avg 1.342
METHODOLOGY: 1. Capital MalaniIgJannnta are Input b be PM column es calculated F he nodal.
2. Net Fiscal ImpadNPV tom opematons celcWaSaea input in tart toad 0l second column
1ze0 It negative); Included ere the nelhna taxes/fees In one year only al lull valet
3. NPV al ANae Wrote equip lame paid In Mad cduon ea cakWatedIn fiscal Impede.
4 NPV of Mute aplIal expenditure tines pad In bulb col as calculated In Isca Impacts.
5. NPV N Abse taxes pad t0 bung current county to to standard for row facilities, as
ra9.udle1 for each new Willy.
4 Columns three through Svc are added as potential aorta against Ile calculated capital
Locales requirements. These ere adjusted (a percent of costs covered by Olerevenues
horn the pio)ed (actual or as ratio to avg. b ail residential development).
NOTE: Poem calculation donut Include Mlude Interest because they ate cash payments up 4ont Cledlle do IOC ysarestV time prclects are EMU (ytante&
NOTES: Model Run Date 10/15114 MIA
Ruled CBecdp0at Assumes a mamma number ol 294 Townhouses and 254.000140318 meet of Office and 440.450 square feet of Ralae.
Total Avenge 150.28 acres (9528 taw B2I54 awes RP re$Uling he mlden6M dlenly 01 &4 units per acre).
Doe b chaining conddols essdated v i develop/mint In the County, bs results of Ws
Output Module may not be stead beyond P plead M 90 days Peon 0e model run dMe.
C wileto beT IarFW ,PtignaG6IBM Total Potential Adjustment For
Cur. Budget Cie. Budget Cep. Future CIPI Ts. C,W�a Revenue. Net Capital Nei Con Per
OOn CSV EeWo Emend/Debt S Tann Mar Nmvdnsledl Cost Deana Fealties impact 0wel1EoJ1f1
SO 50
5159,113 5772,303 8031.508 5831,538
571,653
5163,894
$7 &,960
5D
$169909
5942.302
560.873 580.879 580.873
517,448 117,445 $17,445
51,541 579.194 579,194
50 50 SO
5323.803 5372,603
5485.829
51.408,491
5277,975
544.938
50
947,334
50
91,852
54.194
5946
5163
SO
5151
50
5105,862 51,432,824 51,432,824 51,969,797 ,6
323,664,647 523.064,647 (523064, fin
9 SO
11
8
8
A Traffic Impact Analysis of the
Russell Farm
Located in:
Frederick County, Virginia
Prepared for:
Greenway Engineering
151 Windy Hill Lane
Winchester, VA
22606
Prepared by:
Patton Harris Rust Associates, pc
Engineers. Si rveyors. Ranners. Landscape Architects.
208 Church Street, SE
g Leesburg, Virginia 20175
p RA 703.777.3816
F
AY 1 F 703.777.3725
November 1, 2004
OVERVIEW
Report Summary
Patton Harris Rust Associates, pc (PHR +A) has prepared this document to
present the traffic impacts associated with the proposed Russell Farm development located
along the west side of Route 522 (Front Royal Pike), between Peppermill Road and Route
17/50, in Frederick County, Virginia. The proposed project is to include 294 townhouse
units, 264,000 square feet of office and 440,450 square feet of retail with primary access to
be provided via the proposed western leg of Airport Road and secondary access
(townhouse only) to be provided via a site driveway located to the south of Airport Road.
The proposed development will be built -out by the year 2010. Figure 1 is provided to
illustrate the location of the Russell Farm site with respect to the surrounding roadway
network.
Methodology
The traffic impacts accompanying the Russell Farm development were obtained
through a sequence of activities as the narratives that follow document:
Assessment of background traffic including other planned projects in the area of
impact,
Calculation of trip generation for Russell Farm,
Distribution and assignment of Russell Farm generated trips onto the study area road
network,
Analysis of capacity and level of service using the newest version of the highway
capacity software, HCS -2000, for existing and future conditions.
EXISTING CONDITIONS
Patton Harris Rust Associates, pc (PHR +A) obtained AM and PM peak hour
manual turning movement counts at the intersections of Papermill Road (Route
644)/Pleasant Valley Road, Papermill Road/Route 522 (Front Royal Pike), Airport
Road/Route 522 and Route 522/Route 50/17 (Millwood Pike). Additionally, 24 -hour
automatic "tube" counts were conducted along the Papermill Road and Route 522,
respectively. PHR +A established the ADT (Average Daily Traffic) along each of the study
area roadway links using an average "k" factor (the ratio of PM peak hour traffic volumes
to 24 -hour traffic volumes) of 8% as determined from traffic count data provided by the
Virginia Department of Transportation (VDOT). Figure 2 shows the existing ADT and
AM /PM peak hour traffic volumes at key locations throughout the study area. Figure 3
shows the respective existing lane geometry and AM/PM peak hour levels of service. All
traffic count data and HCS -2000 levels of service worksheets are included in the Appendix
section of this report.
A Phased Traffic Impact Analysis of the Russell Farm
November 1, 2004
Page 1
CONCLUSION
The traffic impacts associated with the proposed Russell Farm development are
acceptable and manageable. The following describes the future operating conditions at
each of the study area intersections.
Route 522 and I -81 ramp/Route 17/50: For existing, 2010 background and build
out conditions, this intersection will operate with levels of service "F This
intersection requires regional roadway improvements to achieve acceptable levels
of service.
Route 17/50 and Ryco Lane: For 2010 background and build -out conditions, this
intersection will operate with levels of service "C" during the AM/PM peak hours.
Traffic signalization, however, would be required to satisfy levels of service
requirements. A signal warrant study would be necessary prior to installation.
Airport Road and Route 522: For 2010 background and build -out conditions, this
intersection will operate with levels of service "C" during the AM and PM peak
hours. Airport Road is proposed to be extended to the site west of Route 522. The
required intersection improvements assumed include a northbound left -turn lane
and southbound right turn lane.
Papermill Road and Route 522: For 2010 background and build -out conditions,
this intersection will operate with levels of service "C" during the AM and PM
peak hours.
Papermill Road and Pleasant Valley Road: For 2010 background and build -out
conditions, this intersection will operate with levels of service "C" during the AM
and PM peak hours. The required intersection improvements assumed include a
northbound left -tum lane and southbound right -turn lane.
A Phased Traffic Impact Analysis of the Russell Farm
November 1, 2004
Page 14
Vicinity Map Russell Farms
A Phased Traffic Impact Analysis of the Russell Farm
November 1, 2004
Page 2
g
0
No Scale
CD 49
o-
S
k o
t.t
5920i
fig
5i
to
7:
ro
IL
L98(180)
e— 79(131)
t /Airport Road
I
u
`at
(1 1i)8
r.
7: 3
ct
c3 a,
l irz3 9 -0
Gcco
ik
AM Peak Hour(PM Peak Hour)
r p.RA
Figure 2 Existing ADT and AM/PM Peak Hour Traffic Volumes
WAWiateifiliisla
A Phased Traffic Impact Analysis of the Russell Farm
November 1, 2004
Page 3
u
No Scale
Signalized
Intersection
LOS =B(C)
e
m
to
a
q D
)tt
i
RA
Signalized
b Intersection
X 3 14' 1 1 LOS--B(B) SITE /IC!'" r BB)
ttf
Signalized
Intersection
LOS =C(F)
1*t
Signalized
Intersection
LOS =B(B)
Po
P,
ANN
N
S` G
uv Unsignalized
Intersection
Denotes Unsignalized Critical Movement
AM Peak Hour (PM Peak Hour)
P
Figure 3
P
Existing Lane Geometry and Levels of Service
A Phased Traffic Impact Analysis of the Russell Farm
November 1, 2004
Page 4
(588)99.) T Airport
(1l8)20" a Iv Road
(235)40 ^A
N
iSIVIREe7DtilyiTriFS
H
Figure 8 2010 Build -out ADT and AM/PM Peak Hour Traffic Volumes
P
A Phased Traffic Impact Analysis of the Russell Farm
November 1, 2004
Page 12
Denotes Unsignalized Critical Movement
r _PHRA AM Peak Hour (PM Peak Hour)
1 Figure 9 2010 Build -out Lane Geometry and Levels of Service
111 A Phased Traffic Impact Analysis of the Russell Farm
November 1, 2004
Page 13
Signalized
Intersectio
LOS=B(C)
T C(C)
1 1 1 Auport
1 Road
Signalized
Intersection
LOS =B(B)
No Scale
Sgnsl(zed Roadway
Intersechosi' Improvements
LOS C(C)= Required
(BP <a
Signalized
Intersection
LOS(C)
Regional
Improvements
Required
Signalized
Intersection
LOS =D(F)
✓i O� It
'r
slgualized Roadway
Intersectta
Los -,qi Improvements
Required
Unsignalized
h B (b). Intersection
'Pike
PHRA
RUSSELL 150
REZONING
The complete Traffic Impact Analysis
is on file in the records of
the Frederick County Department of Planning and Development