HomeMy WebLinkAboutDRRCAgenda2025December111.Zoning Ordinance Text Amendment Proposals
1.A.RP District Dimension Requirements
This is a proposal to amend dimensional requirements for housing types contained in
the RP (Residential Performance) Zoning District to allow for a new housing type, "rear
load townhouses."
This proposed amendment was initiated by a developer.
1.B.Public Utilities - Transmission and Distribution Facilities
This is a proposal to amend Chapter 165 - Zoning Ordinance to include performance
standards for Public Utilities in the RA (Rural Areas) Zoning District and to evaluate
modifying the use permissions in the RA Zoning District.
This ordinance amendment was initiated by the Board of Supervisors.
AGENDA
DEVELOPMENT REVIEW AND REGULATIONS COMMITTEE
THURSDAY, DECEMBER 11, 2025
4:00 PM
FIRST-FLOOR CONFERENCE ROOM
107 NORTH KENT STREET, WINCHESTER VA 22601
DRRC12-11-25OA_RPDimensionRequirements.pdf
DRRC12-11-25OA_PublicUtilities.pdf
1
Development Review and Regulations Committee
Agenda Item Detail
Meeting Date: December 11, 2025
Agenda Section: Zoning Ordinance Text Amendment Proposals
Title: RP District Dimension Requirements
Attachments:
DRRC12-11-25OA_RPDimensionRequirements.pdf
2
ZONING ORDINANCE TEXT AMENDMENT
RP Zoning District Dimensional Requirements
Staff Report for the Development Review and Regulations
Committee (DRRC)
Prepared: December 2, 2025
Staff Contact: Eric Bittner, Planner II
Executive Summary:
Meeting Schedule
Development Review and Regulations
Committee:
Action: None
Planning Commission: January 7, 2026 Action: Pending
Board of Supervisors: January 28, 2026 Action: Pending
Proposal
This is a proposal to amend Chapter 165 - Zoning Ordinance to modify dimensional
requirements for certain housing types in the RP (Residential Performance) Zoning District to
allow for townhouses which are accessed through an alley in the back of the property, referred
to herein as rear-loaded.
Current Standard
Townhouse; back-to-back townhouse
B. Building Setbacks
B1 From public or
private road right-of-
way
With garage: 25 feet Without garage: 15 ft
B2 From off-street
parking lot
15 feet
B3 Side 10 feet
B4 Rear 20 feet Back-to-back option:
N/A
C. Setbacks for unroofed decks, stoops, landings and similar features
C1 Front from off-
street parking lot
10 feet
C2 Front from
private/public road
15 feet
C3 side (end unit) 5 feet
C4 Rear 5 feet
3
Page 2 of 4
Planning & Zoning Staff Analysis:
This ordinance amendment was requested by Pennoni Associates, Inc in a letter to the Planning
and Zoning Department dated August 25, 2025. This ordinance amendment would allow for the
townhouses that are accessed through the rear via an alley. The primary changes are in a reduction
to the required rear setbacks if the townhouses are rear loaded.
One concern noted by staff is that the 18-foot (FT) driveway referenced in Pennoni’s letter is not
reflected in the proposed changes. Similarly, this distance is not included in the 6-FT rear setback
that is proposed. The 6-FT setback is not likely to be utilized as the building would probably need
to be a further distance from the alley to accommodate the required off-street parking.
Frederick Water has expressed concern over underground utilities being provided via the alley
easement and with sharing the utility easement with other uses which may affect or be affected by
utility maintenance. A possible alternative to alleviate the concerns raised by Frederick Water could
be to increase the rear setback to 20-FT where no garage is provided and/or allow for a
detached/attached garage up to 6’ from the easement line.
The rear setback concern is not extended to the setbacks for unroofed decks, as these features are
able to be elevated to still allow for parking. Several of the proposed changes should be better
specified to apply rear loaded townhouses, namely the reduction of the side yard to 5 feet. Staff do
not believe this change is necessary to adequately accommodate this use. The allowance for a
reduced side setback reduction in sub-section B2 (see below, “Proposed Standard”) and the setback
reduction without a garage in sub-section C2 are not necessary to accommodate rear loaded
townhouses.
Additionally, it should be considered that the required off-street parking of 2.5 spaces may be
supplied through parking bays within a development and would likely not need to be fully captured
on the individual lots. For example, a developer could provide a 2-car garage or driveway, then
provide off-street parking elsewhere in the development.
If approved, this amendment would become an administrative requirement, allowing rear-loaded
townhouses as a by-right use in the RP district, no approvals or waivers would be necessary from
the Board of Supervisors.
Other Jurisdictions:
Staff reviewed regulations for townhouses in other Virginia localities which allow rear-loaded
townhouses. In instances where localities had differing regulations depending on the zoning
district, the comparison was pulled using districts of comparable density limitations and land uses
to the RP district. Of note, multiple jurisdictions did not distinguish rear-loaded and front-loaded
townhouses. Those that did typically had a slightly reduced front setback, but an unaltered rear
setback requirement. These localities also typically allowed for detached garages in the rear with
a reduced setback. Most jurisdictions have setbacks which exceed the proposed setbacks, typically
having a rear setback of 15’ or 25’ and front setback of 25’.
4
Page 3 of 4
A cross -comparison of other Virginia localities is included as an attachment to this report.
Proposed Standard
§165-402.09. H. – Dimensional Requirements
Townhouse; back-to-back townhouse, rear alley townhouse
B. Building Setbacks
B1 From public or
private road right-of-
way
With garage: 25 feet Without garage: 15 ft Rear alley option:
The front setbacks
may be reduced to
15 feet, provided
the residential unit
utilizes a rear
alley access and
there are no
driveways on the
private or public
road fronting the
residential unit.
B2 From off-street
parking lot
15 feet Side setback may be
reduced to 10 feet
when adjacent to
private roadway or
parking lot
B3 Side 10 feet 5 feet 5 feet
B4 Rear 20 feet Back-to-back option:
N/A
Rear alley option: 6
feet from shared
alley access
easement
C. Setbacks for unroofed decks, stoops, landings and similar features
C1 Front from off-
street parking lot
10 feet 5 feet 5 feet
C2 Front from
private/public road
15 feet Without garage 10
feet
Rear alley option:
10’
C3 side (end unit) 5 feet Rear alley option: 2’
from shared rear
alley access
easement
C4 Rear 5 feet
5
Page 4 of 4
Summary & Requested Action:
The Board of Supervisors discussed this ordinance amendment at their November 12, 2025,
meeting and made a motion to direct staff to take the ordinance amendment forward for further
study and to authorize staff to hold public hearings. In their discussion the Board expressed support
for having additional options for more diverse housing types to meet changing market trends, as
well as concerns regarding parking and overall affordability.
This item is presented to the Development Review and Regulations Committee (DRRC) for
information and discussion. Staff are seeking comments from the DRRC to forward to the Planning
Commission and Board of Supervisors for consideration.
Questions regarding the proposal should be directed to Planning and Development department
staff.
No action is required by the committee. Comments will be provided directly to the Planning
Commission and Board of Supervisors.
6
§ 165-402.09. Dimensional requirements.
The following dimensional requirements shall be met by uses in the RP Residential Performance
District. The Zoning Administrator shall make the final determination as to the classification of
housing types. Unless otherwise specified, all housing types shall be served by public sewer and
water.
A. Single-family detached rural traditional. This dwelling type consists of a fully detached,
large-lot single-family residence on an individual lot with private yards on all four sides,
without public sewer and water. Dimensional requirements shall be as follows:
A. Lot Dimensions
A1 Minimum lot area 100,000 square feet
A2 Minimum lot depth to width ratio 1:3
B. Building Setbacks
B1 From road right-of-way 60 feet
B2 Side 15 feet
B3 Rear 50 feet
C. Setbacks for unroofed decks, stoops, landings and similar features
C1 Front from road right-of-way 50 feet
C2 Side 10 feet
C3 Rear 35 feet
D. Minimum Parking
D1 Required off-street parking 2 per unit
E. Height
E1 Principal building (max) 35 feet
E2 Accessory building (max) 20 feet
B. Single-family detached traditional. This dwelling type consists of a fully detached, large-
lot single-family residence with private yards on all four sides without required common
open space. Dimensional requirements shall be as follows:
A. Lot Dimensions
A1 Minimum lot area 15,000 square feet
A2 Minimum lot width at setback 80 feet
B. Building Setbacks
B1 From road right-of-way 35 feet
B2 Side 10 feet
Frederick County, VA
Downloaded from https://ecode360.com/FR1364 on 2025-11-06
7
B3 Rear 25 feet
C. Setbacks for unroofed decks, stoops, landings and similar features
C1 Front from road right-of-way 25 feet
C2 Side 5 feet
C3 Rear 15 feet
D. Minimum Parking
D1 Required off-street parking 2 per unit
E. Height
E1 Principal building (max) 35 feet
E2 Accessory building (max) 20 feet
C. Single-family detached urban. This dwelling type consists of a fully detached, single-
family residence on an individual lot with private yards on all four sides. Dimensional
requirements shall be as follows:
A. Lot Dimensions
A1 Minimum lot area 12,000 square feet
A2 Minimum lot width at setback 70 feet
A3 Minimum lot width at road right-of-way 40 feet
B. Building Setbacks
B1 From road right-of-way 35 feet
B2 Side 10 feet
B3 Rear 25 feet
C. Setbacks for unroofed decks, stoops, landings and similar features
C1 Front from road right-of-way 25 feet
C2 Side 5 feet
C3 Rear 15 feet
D. Minimum Parking
D1 Required off-street parking 2 per unit
E. Height
E1 Principal building (max) 35 feet
E2 Accessory building (max) 20 feet
D. Single-family detached cluster. This dwelling type consists of a fully detached, single-
family residence on an individual lot, with private yards on all four sides. Dimensional
Frederick County, VA
§ 165-402.09 § 165-402.09
Downloaded from https://ecode360.com/FR1364 on 2025-11-06
8
requirements shall be as follows:
A. Lot Dimensions
A1 Minimum lot area 8,000 square feet
A2 Minimum lot width at setback 60 feet
A3 Minimum lot width at road right-of-way 30 feet
B. Building Setbacks
B1 From road right-of-way 25 feet
B2 Side 8 feet
B3 Rear 20 feet
C. Setbacks for unroofed decks, stoops, landings and similar features
C1 Front from road right-of-way 15 feet
C2 Side 5 feet
C3 Rear 10 feet
D. Minimum Parking
D1 Required off-street parking 2 per unit
E. Height
E1 Principal building (max) 35 feet
E2 Accessory building (max) 20 feet
E. Single-family detached zero lot line. This dwelling type consists of a fully detached, single-
family residence on an individual lot. The building is set on one of the side property lines,
with a maintenance easement on the adjoining lot. Dimensional requirements shall be as
follows:
A. Lot Dimensions
A1 Minimum lot area 6,000 square feet
B. Building Setbacks
B1 From road right-of-way 25 feet
B2 Minimum on-site building spacing (side) 25 feet
B3 Rear 25 feet
C. Setbacks for unroofed decks, stoops, landings and similar features
C1 Front from road right-of-way 15 feet
C2 Side 20 feet
C3 Rear 15 feet
Frederick County, VA
§ 165-402.09 § 165-402.09
Downloaded from https://ecode360.com/FR1364 on 2025-11-06
9
D. Minimum Parking
D1 Required off-street parking 2 per unit
E. Height
E1 Principal building (max) 35 feet
E2 Accessory building (max) 20 feet
F. Supplemental Regulations
F1 A maintenance easement of 10 feet in width must be obtained on the lot adjacent to the
zero lot line side.
F2 The opposite side yard must be maintained clear of any obstructions other than a three-
foot eaves encroachment, swimming pools, normal landscaping, removable patio covers
extending no more than five feet or garden walls or fences. In no case shall any
encroachment other than a fence be placed within the required maintenance easement.
F3 The zero lot line side must not be adjacent to a road right-of-way.
F. Single-family small lot. This dwelling type consists of a single-family detached or attached
residence on an individual lot. No more than two units may be attached together.
Dimensional requirements shall be as follows:
A. Lot Dimensions
A1 Minimum lot area 3,750 square feet
B. Building Setbacks
B1 From public or private
road right-of-way
25 feet
B2 The front setback may be reduced to 15 feet, provided that the residential unit utilizes a
rear alley for access and there are no driveways on the private or public road fronting the
residential unit.
B3 Side Detached option: 5 feet Attached option: 10 feet
B4 Rear 15 feet
B5 Minimum building
spacing
Attached option: 20 feet
C. Setbacks for unroofed decks, stoops, landings and similar features
C1 Front from private/public
road
15 feet Rear alley option: 10 feet
C2 Side (end unit) 5 feet
C3 Rear 10 feet
C4 Rear (from open space) 5 feet
D. Minimum Parking
Frederick County, VA
§ 165-402.09 § 165-402.09
Downloaded from https://ecode360.com/FR1364 on 2025-11-06
10
D1 Required off-street
parking
2 per unit
E. Height
E1 Principal building (max) 35 feet
E2 Accessory building (max) 20 feet
F. Supplemental regulations
F1. A minimum of 20 landscape plantings shall be provided on each individual lot. At
least 1/4 of the landscape plantings shall be trees, with the remainder being shrubs. The
trees shall be a minimum of two inches in caliper at time of planting, and the shrubs shall
be a minimum of three.
F2. Detached accessory structures may not exceed 150 square feet.
G. Multiplex. A "multiplex" is an attached residence containing three to four dwelling units.
Units may or may not have independent outside access. Units within multiplex structures
may be arranged side to side, back to back or vertically. Dimensional requirements shall be
as follows:
A. Lot Dimensions
A1 Minimum lot area per unit 3,000 square feet
A2 Maximum site impervious surface ratio 0.50
B. Building Setbacks
B1 From road right-of-way 35 feet
B2 From parking areas or driveways 20 feet
B3 Side 15 feet from perimeter boundary
B4 Rear 25 feet from perimeter boundary
C. Setbacks for unroofed decks, stoops, landings and similar features
C1 Front from road right-of-way 25 feet
C2 Front from parking areas or driveways 15 feet
C3 Side 10 feet
C4 Rear 15 feet
D. Minimum Parking
D1 Required off-street parking 2 per unit
E. Height
E1 Principal building (max) 35 feet
E2 Accessory building (max) 20 feet
Frederick County, VA
§ 165-402.09 § 165-402.09
Downloaded from https://ecode360.com/FR1364 on 2025-11-06
11
H. Townhouse; back-to-back townhouse. This dwelling type consists of a single-family
attached dwelling unit from ground to roof, with individual outside access. Rows of
townhouses shall contain no more than eight dwelling units in a group. Back-to-back
townhouses shall contain no more than 16 dwelling units in a group. Dimensional
requirements shall be as follows: [Amended 5-25-2022]
A. Lot Dimensions
A1 Minimum lot area 1,500 square feet
A2 Minimum lot width End unit: 22 feet Interior unit: 18 feet
B. Building Setbacks
B1 From public or private road right-of-way With garage: 25 feet Without garage: 15
feet
B2 From off-street parking lot 15 feet
B3 Side 10 feet
B4 Rear 20 feet Back-to-back option:
N/A
C. Setbacks for unroofed decks, stoops, landings and similar features
C1 Front from off-street parking lot 10 feet
C2 Front from private/public road 15 feet
C3 Side (end unit) 5 feet
C4 Rear 5 feet
D. Minimum Parking
D1 Required off-street parking 2.5 per unit
E. Height
E1 Principal building (max) 40 feet
E2 Accessory building (max) 20 feet
I. Garden apartments. This housing type consists of buildings that contain multiple dwelling
units that share a common yard area. The entire dwelling unit does not necessarily have to be
on the same floor. Garden apartments shall be at least two stories high but no more than four
stories and shall contain six or more units in a single structure, not to exceed 16 units within
a single structure. Dimensional requirements shall be as follows:
A. Lot Dimensions
A1 Maximum site impervious surface ratio 0.60
B. Building Setbacks
B1 From public road right-of-way 35 feet
Frederick County, VA
§ 165-402.09 § 165-402.09
Downloaded from https://ecode360.com/FR1364 on 2025-11-06
12
B2 From private road right-of-way, off-
street parking lot or driveway
20 feet
B3 Side (perimeter) 20 feet
B4 Rear (perimeter) 25 feet
B5 Rear for balconies and decks 20 feet
B6 Minimum on-site building spacing: Buildings placed side to side shall have a minimum
distance of 20 feet between buildings; buildings placed side to back shall have a minimum
distance of 35 feet between buildings. Buildings back to back shall have a minimum
distance of 50 feet between buildings.
C. Minimum Parking
C1 Required off-street parking 2 per unit
D. Height
D1 Principal building (max): 55 feet
D2 Accessory building (max) 20 feet
J. Multifamily residential buildings. This housing type consists of multifamily buildings with
a minimum of four dwelling unit entrances sharing an internal corridor per floor. The entire
dwelling unit does not necessarily have to be on the same floor. External corridors are not
permitted. Multifamily residential buildings shall only be located in areas designated in the
Comprehensive Plan as neighborhood villages, urban centers or other areas planned for high-
density residential. Dimensional requirements shall be as follows:
A. Lot Dimensions
A1 Maximum site impervious surface ratio 0.60
B. Building Setbacks
B1 From public road right-of-way 35 feet
B2 From off-street parking lot or driveway 20 feet
B3 Side (perimeter) 50 feet
B4 Rear (perimeter) 50 feet
B5 Rear for balconies and decks 20 feet
B6 Minimum on-site building spacing: Buildings placed side to side shall have a minimum
distance of 20 feet between buildings; buildings placed side to back shall have a minimum
distance of 35 feet between buildings. Buildings back to back shall have a minimum
distance of 50 feet between buildings.
C. Minimum Parking
C1 Required off-street parking 2 per unit
D. Height
Frederick County, VA
§ 165-402.09 § 165-402.09
Downloaded from https://ecode360.com/FR1364 on 2025-11-06
13
D1 Principal building (max): 60 feet, provided that a multifamily residential building may
be erected to a maximum of 80 feet if it is set back from road right-of-ways and from lot
lines in addition to each of the required minimum yard dimensions, a distance of not less
than one foot for each one foot of height that it exceeds the sixty-foot limit.
D2 Accessory building (max) 20 feet
K. Age-restricted multifamily housing. "Age-restricted multifamily housing" is multifamily
buildings where individual dwelling units share a common outside access. They also share a
common yard area, which is the sum of the required lot areas of all dwelling units within the
building. Age-restricted multifamily housing shall only be permitted within proffered age-
restricted developments. Elevator service shall be provided to each floor of age-restricted
multifamily housing structures for use by residents and guests. Dimensional requirements
shall be as follows:
A. Lot Dimensions
A1 Minimum lot area 3 acres
A2 Maximum site impervious surface ratio 0.60
A3 Maximum number of units per building 110
B. Building Setbacks
B1 From road right-of-way 60 feet
B2 From off-street parking lot or driveway 5 feet
B3 Side (perimeter): 100 feet from the perimeter boundary. An additional two feet from
the perimeter boundary shall be added for every foot that the height of the building
exceeds 40 feet when the adjacent use is single-family residences.
B4 Rear (perimeter): 100 feet from the perimeter boundary. An additional two feet from
the perimeter boundary shall be added for every foot that the height of the building
exceeds 40 feet when the adjacent use is single-family residences.
B5 Rear for balconies and decks May extend 10 feet into a perimeter setback
B6 Minimum on-site building spacing: Buildings placed side to side shall have a minimum
distance of 20 feet between buildings; buildings placed side to back shall have a minimum
distance of 35 feet between buildings. Buildings back to back shall have a minimum
distance of 50 feet between buildings.
C. Minimum Parking
C1 Required off-street parking 1.5 per unit
D. Height
D1 Principal building (max): The maximum structure height for any principal building
shall be 40 feet. The Board of Supervisors may waive the forty-foot height limitation,
provided that it will not negatively impact adjacent residential uses. In no case shall any
principal building exceed 60 feet in height.
Frederick County, VA
§ 165-402.09 § 165-402.09
Downloaded from https://ecode360.com/FR1364 on 2025-11-06
14
D2 Accessory building (max) 20 feet
L. Height for other uses. The height for all other uses not otherwise specified shall not exceed
45 feet.
M. Setbacks for accessory structures. Accessory structures shall be set back from all property
lines a minimum of five feet, except for uses with a required enclosed yard.
N. Setbacks for other uses. The following setbacks shall apply to uses not otherwise specified:
(1) Front setback shall be 35 feet.
(2) Side setbacks shall be 15 feet.
(3) Rear setback shall be 50 feet.
O. Setbacks from business and industrial uses. All proposed structures shall be set back 50
feet from the boundary of land zoned for business or industrial uses or land currently
containing business or industrial uses.
P. Pipestem lots. The use of pipestem lots is permitted for single-family detached traditional,
single-family detached urban and single-family detached cluster lot types, if all of the
following design requirements are met:
(1) The total number of pipestem lots in a residential development may not exceed 5% of
the total number of lots.
(2) Pipestem lots shall have a minimum road frontage of 20 feet.
(3) Pipestem lot driveways shall access only one lot.
(4) Minimum yards shall be as follows:
(a) Front, side and rear yards: 20 feet.
(b) Accessory buildings: 20 feet.
(c) Side yard of lots adjoining pipestem driveway yard: 15 feet.
(5) Pipestem lot driveways shall not adjoin other pipestem driveways.
(6) Unless specified differently above, pipestem lots shall comply with all other regulations
of the Frederick County Zoning and Subdivision Ordinances.
Frederick County, VA
§ 165-402.09 § 165-402.09
Downloaded from https://ecode360.com/FR1364 on 2025-11-06
15
117 East Piccadilly Street
Winchester, VA 22601
T: 540-667-2139
F: 540-665-0493
www.pennoni.com
August 25, 2025
Mr. Mark Cheran
Zoning Administrator
Frederick County, Virginia
107 North Kent Street
Winchester, Virginia 22601
RE: Section 165-402.09.H Townhouse Text Amendment
Alley Served - Rear Load Townhouses
Mr. Cheran:
Pennoni understands that Frederick County has been investigating potential updates to the Zoning
Ordinance that would accommodate contemporary housing products. Please accept this letter as a
formal request for inclusion of the rear alley served townhouse product type that other communities
is Virginia allow to be constructed by utilizing existing zoning ordinances.
Specifically, the residential land development community would like to propose an additional
townhouse housing option allowable within the RP zoning district of the Frederick County Zoning
Ordinance. Section 165-402.09.H Townhouse; back-to-back townhouse, of the Frederick County
Zoning Ordinance currently does not provide for a commonly constructed rear alley served townhouse
unit. The following dimensional requirements & design standards are proposed for use with an alley
served - rear load townhouse:
1. The front yard building setbacks from any public or private right-of-way may be reduced to
15 feet.
2. The side yard building setbacks adjacent any private right-of-way may be reduced to 10 feet.
3. The rear building setback will be 6 feet from the rear alley access easement.
4. The setbacks for unroofed decks, stoops, landings and similar features will be 10 feet in the
front, 5 feet adjacent off-street parking lot, 5 feet on side and 2 feet in rear from private
roadway easement.
5. The rear property line will be the centerline of the Alley.
6. A portion of the Alley will count as a portion of the minimum lot area.
7. The units will have parking and access to the garages from the rear, served by an alley.
8. A minimum 18-foot depth driveway outside of the alleyway shall be required in the rear to
count as parking space in addition to garage spaces.
See the attached “Alley Served – Rear Load Townhouse Schematic” for a graphical representation
of the above requirements and a redline mark-up of how Section 165-402.09.H may be modified to
accommodate the proposed unit type.
As always, we appreciate your time and consideration on this request. If you have any questions,
please feel free to contact the Pennoni office at (540) 771-2087.
Sincerely,
PENNONI ASSOCIATES INC.
David L. Frank, PLA
16
Townhouse; back-to-back townhouse, rear alley townhouse. This dwelling type consists of a
single-family attached dwelling unit from ground to roof, with individual outside access. Rows of
townhouses shall contain no more than eight dwelling units in a group. Back-to-back townhouses shall
contain no more than 16 dwelling units in a group. Dimensional requirements shall be as follows:
[Amended 5-25-2022]
A. Lot Dimensions
A1 Minimum lot area 1,500 square
feet
A2 Minimum lot width End unit: 22
feet
Interior
unit: 18
feet
B. Building Setbacks
B1 From public or private road
right-of-way
With garage:
25 feet
Without
garage: 15
feet
Rear alley option: The front setbacks
may be reduced to 15 feet, provided
the residential unit utilizes a rear
alley access and there are no
driveways on the private or public
road fronting the residential unit.
B2 From off-street parking lot 15 feet
Side setback may be reduced to 10
feet when adjacent to private
roadway or parking lot
B3 Side 10 feet 5 feet 5 feet
B4 Rear 20 feet Back-to-
back
option:
N/A
Rear alley option: 6 feet from shared
rear alley access easement.
C. Setbacks for unroofed decks, stoops, landings and similar
features
C1 Front from off-street
parking lot
10 feet 5 feet 5 feet
C2 Front from private/public
road
15 feet Without
garage: 10
feet
Rear alley option: 10’
C3 Side (end unit) 5 feet
C4 Rear 5 feet
Rear alley option: 2’ from shared
rear alley access easement
D. Minimum Parking
D1 Required off-street parking 2.5 per unit
E. Height
E1 Principal building (max) 40 feet
17
E2 Accessory building (max) 20 feet
18
7 - UNIT TOWNHOUSE
ALLEY SERVED - REAR LOAD
7 - UNIT TOWNHOUSE
ALLEY SERVED - REAR LOAD
PUBLIC ROAD
24 ACCESS
ESMT 24' ACCESSESMTROAD R/W (TYP)
ROAD R/W (TYP)ACCESS ESMT (TYP)PROPERTY LINE (TYP)PROPERTY LINE (TYP)6' REARSETBACK15' FRONTSETBACK22' END
UNIT (MIN)
18' INTERIOR
UNIT (MIN)6' REARSETBACKPROPERTY LINE (TYP)FRONT BLDG SETBACK
REAR BLDG SETBACK
PUBLIC ROAD
PRIVATE ALLEY
PRIVATE ALLEYREAR BLDG SETBACK
FRONT BLDG SETBACK
10'
SIDE
SETBACK
PROPERTY LINE (TYP)10' SIDESETBACK(CORNER)15' FRONTSETBACKLOT DEPTH (TYP)10' SIDE
SETBACK
(CORNER)ACCESS ESMT (TYP)5 - UNIT TOWNHOUSEALLEY SERVED - REAR LOAD6' REAR
SETBACK
PROPERTY LINE (TYP)REAR BLDG SETBACKFRONT BLDG SETBACK15' FRONT
SETBACK 15' FRONTSETBACK(CORNER)PUBLIC ROAD15' FRONTSETBACK(CORNER)ACCESS ESMT (TYP)ESDIX24001 | 06/18/2025
REVISED: 08/26/2025 NORTHU:\ACCOUNTS\ESDIX\ESDIX25001 - CROSSPOINTE\DESIGN\_EXHIBITS\REAR LOAD TH\REAR LOAD TH SCHEMATIC.DWG
PENNONI ASSOCIATES INC.
117 East Piccadilly Street
Winchester, VA 22601
T 540.667.2139 F 540.665.0493
ALLEY SERVED - REAR LOAD TOWNHOUSE SCHEMATIC
00 25'50'
GRAPHIC SCALE 1"=25'
19
20
21
22
23
24
25
Stafford County Henrico County Chesterfield County Rockingham County Prince William County Loudoun County Roanoke County Winchester City Shenandoah County
front setback 8'25 20 25 0 15'10'35'40'
rear setback 25 30 15 15 30'15'25'25'/50*40'
side setback 15 20 10'8'15'6'/10'*10'
garage (rear)0 5'10'
*if adajcent to lower density district
26
Development Review and Regulations Committee
Agenda Item Detail
Meeting Date: December 11, 2025
Agenda Section: Zoning Ordinance Text Amendment Proposals
Title: Public Utilities - Transmission and Distribution Facilities
Attachments:
DRRC12-11-25OA_PublicUtilities.pdf
27
ZONING ORDINANCE TEXT AMENDMENT
Public Utilities – Transmission and Distribution Facilities
Staff Report for the Development Review and Regulations
Committee (DRRC)
Prepared: December 5, 2025
Staff Contact: M. Tyler Klein, AICP, Senior Planner
Executive Summary:
Meeting Schedule
Development Review and Regulations
Committee:
Action: None
Planning Commission: January 7, 2026 Action: Pending
Board of Supervisors: January 28, 2026 Action: Pending
Proposal
This is a proposal to amend Chapter 165 - Zoning Ordinance to add performance standards for
“Public Utilities – Transmission and Distribution Facilities” and/or evaluate if the use should
be a conditional use requiring a conditional use permit.
Current Standard
Public Utilities – Transmission and Distribution Facilities are currently allowed as a permitted
use in the RA Zoning District (§165-401.02(Q)) and all other zoning districts by-right. The use
allowances for” “Public Utilities” was last modified in 2025 in conjunction with the data
center ordinance amendment.
“Additional Regulations for Specific Uses” contained in §165-204.26 for Public Utilities allow
the Zoning Administrator the authority to determine minimum lot size and appropriate
setbacks. The “Additional Regulations for Specific Uses” was last amended in 2020 to specify
requirements for “utility-scale solar power generating facilities.” Prior to that, the section was
last amended in 2020 and 2011 respectively.
Planning & Zoning Staff Analysis:
The Planning Commission, at their November 5, 2025, meeting, made a motion to request the
Board of Supervisors direct staff to develop a draft ordinance addressing electrical substations in
the County. In their discussion, the Planning Commission directed staff to consider performance
standards that could include enhanced buffer and screening requirements for substations, including
an earthen berm and/or other screening, increased setbacks, siting requirements near existing
transmission lines, and prohibiting siting where adjoining residential uses. Additionally, staff were
directed to evaluate if a conditional use permit (CUP) should be required for the rural areas.
28
Page 2 of 4
The Board of Supervisors discussed this ordinance amendment at their November 12, 2025,
meeting and made a motion to direct staff to take the ordinance amendment forward for further
study and to authorize staff to hold public hearings. In their discussion the Board expressed support
for including additional regulations in the ordinance but did not provide consensus on requiring a
conditional use permit.
Public facilities, such as electrical substations, also require Planning Commission approval of the
proposed facility and site being in conformance with the Comprehensive Plan (2021) following a
public hearing. Specifically, this process determines if the general or approximate location,
character and extent are in substantial accord with the Frederick County Comprehensive Plan. If
the Planning Commission finds a proposal to be inconsistent with adopted Plan policy, they could
deny the request for a 2232 review.
The 2232 process gives the Planning Commission limited control over siting and performance
standards, outside of a conditional use permit process, as it is primarily evaluating consistency
with the Comprehensive Plan.
Presently, there is not a proposal included below to modify the current by-right allowance to a
“conditional use” requiring a conditional use permit (CUP) in the RA District. However, making
such a change would be relatively simple if so directed.
Other Jurisdictions:
Staff reviewed the regulations for substations in other Virginia localities. Most other jurisdictions
require a “special exception” (i.e. a conditional use permit) or similar public process for electrical
substations on properties primarily zoned for agricultural/residential uses in addition to the state
code required 2232 review. Additionally, most if not all the other localities that reviewed include
performance standards to regulate setbacks, screenings, landscaping, and other elements of site
design. Typical performance standards included minimum setbacks (varying from 50-feet to 100-
FT from residential uses), screening required (varying from 8-FT to 12-FT tall wall or fence), and
buffers (with planting sizes of 6-FT tall trees and 42-48-inch-tall shrubs). It is important to note
that species for plantings need to be considered carefully as many typical screening trees can grow
to mature heights that would be incompatible with overhead utility lines. Additionally, some
localities require co-location studies and/or environmental noise impact assessments when
considering electrical substation citing.
A cross comparison of other Virginia localities is included as an attachment to this report.
Proposed Standard:
Article I – General Provisions; Amendments; and Conditional Use Permit.
Part 101 – General Provisions.
§165-101.02 Definitions and word usage.
29
Page 3 of 4
PUBLIC UTILITIES, TRANSMISSION VOLTAGE ELECTRICAL SUBSTATION
Electrical substation intended for long range transmission of wholesale electrical power with
voltages 138KV and higher. Such facilities may be owned by public utilities, public agencies,
those operators with a certificate of public convenience, or those that are operation under a
permit-by-rule (PBR).
PUBLIC UTILITIES, DISTRIBUTION VOLTAGE ELECTRICAL SUBSTATION
Electrical substation intended for local distribution of retail electrical power with voltages
138KV and lower. Such facilities may be owned by public utilities with retail territory defined
by the Virginia State Corporation Commission (SCC).
Article II – Supplementary Use Regulations; Parking; Buffers; and Regulations for Specific Uses
Part 204 – Additional Regulations for Specific Uses
§165-204.26 – Public Utilities
3.Transmission Voltage Electrical Substations in the RA (Rural Areas) zoning district.
A.A modified Category C Type full screen buffer is required around the perimeter of the
facility. The following enhanced landscaping and screening requirements apply:
1)A minimum 8-foot-tall opaque fence, wall or berm shall be provided.
a. Chain-link fencing with slats, with a privacy factor of 90% or greater, may
be utilized to satisfy the opaque fence requirements
b. Chain-link fencing with slats shall consist of double-walled winged slats; or
equivalent if approved by the Zoning Administrator.
c.Chain-link fencing with slats shall only utilize the following colors: dark
green, brown, black, or tan. The use of wood slats or plastic slats without
interlocking wings and double walls shall be prohibited.
2)Deciduous trees shall be a minimum of one-and-one-half-inch caliper, and a
minimum of six feet tall, at the time of planting.
3)Evergreen trees shall be a minimum of six feet in height at the time of planting.
4)Shrubs shall be a minimum of 36 inches in height at time of planting.
5)All other landscaping requirements, not modified above and contained in §165-
203.01 shall apply.
4.Distribution Voltage Electrical Substation in the RA (Rural Areas) zoning district.
A.A Category B Type full screen buffer, satisfying requirements contained in §165-
203.02(D), is required around the perimeter of the facility.
a. Chain-link fencing with slats, with a privacy factor of 90% or greater, may be
utilized to satisfy the opaque fence requirements
b. Chain-link fencing with slats shall consist of double-walled winged slats; or
equivalent if approved by the Zoning Administrator.
30
Page 4 of 4
c.Chain-link fencing with slats shall only utilize the following colors: dark green,
brown, black, or tan. The use of wood slats or plastic slats without interlocking
wings and double walls shall be prohibited.
Summary & Requested Action:
This ordinance amendment to add definitions and “Additional Regulations for Specific Uses” for
“Public Utilities – Transmission and Distribution Facilities” in the RA Zoning District is presented
to the Development Review and Regulations Committee (DRRC) for information and discussion.
Staff is seeking comments from the DRRC to forward to the Planning Commission and Board of
Supervisors for consideration.
Questions regarding the proposal should be directed to Planning and Development department
staff.
No action is required by the committee. Comments will be provided directly to the Planning
Commission and Board of Supervisors.
31
Proposed Changes – Public Utilities – Transmission and Distribution Facilities
Drafted December 5, 2025
Chapter 165 – Zoning Ordinance
Article I – General Provisions; Amendments; and Conditional Use Permit.
Part 101 – General Provisions.
§165-201.02 Definitions and word usage.
PUBLIC UTILITIES, TRANSMISSION AND DISTRIBUTION FACILITIES
Booster or relay stations, transmission lines and towers, pipes, meters and other facilities, and
sewer and water treatment facilities, including sewer and water transmissions lines. Such facilities
may be owned by public utilities, public agencies, those operators with a certificate of public
convenience, or those that are operation under a permit-by-rule (PBR).
PUBLIC UTILITIES, TRANSMISSION VOLTAGE ELECTRICAL SUBSTATION
Electrical substation intended for long range transmission of wholesale electrical power with
voltages 138KV and higher. Such facilities may be owned by public utilities, public agencies,
those operators with a certificate of public convenience, or those that are operation under a
permit-by-rule (PBR).
PUBLIC UTILITIES, DISTRIBUTION VOLTAGE ELECTRICAL SUBSTATION
Electrical substation intended for local distribution of retail electrical power with voltages
138KV and lower. Such facilities may be owned by public utilities with retail territory defined
by the Virginia State Corporation Commission (SCC).
Article II – Supplementary Use Regulations; Parking; Buffers; and Regulations for Specific Uses
Part 204 – Additional Regulations for Specific Uses
§165-204.26 – Public Utilities
Public utilities. Lot requirements for lots used by political subdivisions, municipal corporations,
the Virginia Department of Transportation, the Frederick-Winchester Service Authority, or the
Frederick Water for public utility purposes shall be as follows:
A. In all zoning districts, the Zoning Administrator shall have the authority to determine the
minimum lot size necessary for such public utilities and the appropriate setbacks for such
lots used for public utility purposes.
B. Such lots shall be exempt from the individual on-site sewage disposal system
requirements.
C. Such lots may be accessed by private access easements; any such easement shall be a
minimum of 15 feet in width.
2. Utility-scale solar power generating facilities.
A. Any owner, lessee, or developer of real property for the purposes of solar power energy
generation shall enter into a written agreement, prior to site plan approval, with Frederick
32
Proposed Changes – Public Utilities – Transmission and Distribution Facilities
Drafted December 5, 2025
County to decommission solar energy equipment, facilities, or devices pursuant to the
terms and conditions of § 15.2-2241.2(B) of the Code of Virginia.
B. For utility-scale solar power generating facilities a site plan, in accordance with Article
VIII, shall be submitted to and approved by Frederick County, prior to the establishment
of the use.
3. Transmission Voltage Electrical Substations in the RA (Rural Areas) zoning district.
A. A modified Category C Type full screen buffer is required around the perimeter of the
facility. The following enhanced landscaping and screening requirements apply:
1) A minimum 8-foot-tall opaque fence, wall or berm shall be provided.
a. Chain-link fencing with slats, with a privacy factor of 90% or greater, may
be utilized to satisfy the opaque fence requirements
b. Chain-link fencing with slats shall consist of double-walled winged slats; or
equivalent if approved by the Zoning Administrator.
c. Chain-link fencing with slats shall only utilize the following colors: dark
green, brown, black, or tan. The use of wood slats or plastic slats without
interlocking wings and double walls shall be prohibited.
2) Deciduous trees shall be a minimum of one-and-one-half-inch caliper, and a
minimum of six feet tall, at the time of planting.
3) Evergreen trees shall be a minimum of six feet in height at the time of planting.
4) Shrubs shall be a minimum of 36 inches in height at time of planting.
5) All other landscaping requirements, not modified above and contained in §165-
203.01 shall apply.
4. Distribution Voltage Electrical Substation in the RA (Rural Areas) zoning district.
A. A Category B Type full screen buffer, satisfying requirements contained in §165-
203.02(D), is required around the perimeter of the facility.
a. Chain-link fencing with slats, with a privacy factor of 90% or greater, may be
utilized to satisfy the opaque fence requirements
b. Chain-link fencing with slats shall consist of double-walled winged slats; or
equivalent if approved by the Zoning Administrator.
c. Chain-link fencing with slats shall only utilize the following colors: dark green,
brown, black, or tan. The use of wood slats or plastic slats without interlocking
wings and double walls shall be prohibited.
33
Town of Ashland Fairfax County Loudoun County Henrico County Prince William County Rockingam County Albermarle County
Permission for rural and agricultural
areas Conditional Use Not Allowed in Residential-Agricultural
District Special Exception Special Use Special Permit Special Use Special Use
50' from streets 100' from residential 50' from agricultural uses 60' road 75' front
100' from residential uses (within 50-
300 feet of the facility)20' from non-residential uses 20' from all other uses 15' side 25' side
20' from other uses
50' minimum setback from residential
for electric substation serving a
specific project
20' from roadways 25' rear 35' rear
8' tall screen; deciduous and evergreen
trees
Screened by a wall or fence a
minimum 12' in height
In all agricultural and residential
districts utility substations
(distribution) shall be located on lots of
1-acre or more.
10' tall opaque fence One (1) parking space per facility
The proposed use at the location selected
will not endanger the health and safety of
workers and/or residents in the community
and will not impair or prove detrimental to
neighboring properties or the development
of same.
Decommissioning policies
Mixed buffer yard a minimum of 50' in
width where adjoining residential uses;
large and medium trees and evergreen
shrubs; minimum 6' in height for trees;
42-48" tall shrubs
All Utility Substations and accessory
storage yards require a minimum Buffer
Type C, however, if required utility
connections preclude installation of large
and small deciduous trees, the maximum
percentage applicable to shrubs under
Section 7.04.07.B.2.d does not apply. In
lieu of the minimum and maximum
percentages applicable to evergreen
trees under Section 7.04.07.B.2.b, at least
40% and up to 70% of the required plant
units must be evergreen trees.
located outside of front setback
Public utility buildings and structures
in any residential zone shall, wherever
practical, have the exterior appearance
of residential buildings and shall have
landscaping, screen planting and/or
fencing, whenever these are deemed
necessary by the commission.
Noise study required Must be located in areas consistent
with Comprehensive Plan.
Such structures as towers,
transmission lines, transformers, etc.,
which are abandoned, damaged or
otherwise in a state of disrepair, which
in the opinion of the zoning
administrator pose a hazard to the
public safety, shall be
repaired/removed to the satisfaction of
the zoning administrator within a
reasonable time prescribed by the
zoning administrator.
If the proposed location is in a R
district, the use may be permitted only
upon finding by the Board that the
proposed location is a co-location or
expansion of an existing facility and
would minimize adverse effects in the
R district compared to alternative sites;
or there is no alternative site in a
commercial or industrial district that
can provide satisfactory service within
one mile of the propose location.
Utility Substations may be accessed by
a private road.
Minimum Setback
Performance Standards
Utility Substations must be set back a
minimum of 100 feet from adjacent
property with existing residential
development
200'